WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY Auditor’s Toolbox WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Learning Objectives AUDITOR’S TOOLBOX By attending this session, participants will: • Be familiar with typical auditing tools. • Gain an understanding of basic test procedures. • Be exposed to more advanced test procedures. 2 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov The Audit Field Form AUDITOR’S TOOLBOX 3 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Basic Audit Tools AUDITOR’S TOOLBOX Photos courtesy of The US Department of Energy 4 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Tool Case AUDITOR’S TOOLBOX Photos courtesy of The US Department of Energy 5 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Specialized Tools AUDITOR’S TOOLBOX Photos courtesy of The US Department of Energy 6 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Vision Enhancers AUDITOR’S TOOLBOX Sony digital camera Boroscope Testo Video Pro Flir Infrared Photos courtesy of The US Department of Energy 7 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Combustion Appliance Testing AUDITOR’S TOOLBOX Photos courtesy of The US Department of Energy Above (left to right): Above counter-clockwise from lower left: • Thermometer. • Pipe wrenches. • Gas leak detection bubbles. • Draft Gauge. • Long lighter. • Inspection mirror. • Gas leak detector. • Smoke pump and smoke test filter paper. • Inspection mirror. • Combustion analyzer. 8 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Combustion Appliance Test Kit AUDITOR’S TOOLBOX Keep one case just for combustion testing: • Smoke pump and filter paper. • Lighter. • Combustion analyzer and manual. • High-temp sealant. • Appropriate drill bits for test holes. • Organization! Photo courtesy of The US Department of Energy 9 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Blower Door AUDITOR’S TOOLBOX Photo courtesy of The US Department of Energy 10 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Manometers & Gauges AUDITOR’S TOOLBOX Magnahelic gauges DG-700 (Energy Conservatory) 11 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 DM-2 (Retrotec) eere.energy.gov Blower Door with Infrared AUDITOR’S TOOLBOX Without Blower Door With Blower Door Running 12 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov “Feathering” at a Dropped Soffit AUDITOR’S TOOLBOX The feathery edged areas extending across the ceiling are caused by cold outside air being pulled in through a crack between the dropped box soffit and the ceiling. Ceiling Wall 13 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Smoke AUDITOR’S TOOLBOX Wizard Stick Photos courtesy of The US Department of Energy 14 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Pressure Pan AUDITOR’S TOOLBOX Photo courtesy of The US Department of Energy 15 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Diagnosing Ducts AUDITOR’S TOOLBOX Common mobile home duct pattern Bedroom Bedroom Bath Furnace Closet (living rm) Living Room Kitchen Kitchen 0.8 Pa 1.2 Pa 2.4 Pa 2.6 Pa 2.0 Pa 1.2 Pa 0.5 Pa Total: 10.7 Pa = seal ducts 2.4 Pa at bath register & 2.6 Pa at living room register indicate a large leak between them, most probably at the furnace plenum. Photo Source: US Department of Energy 16 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Blaster AUDITOR’S TOOLBOX Photo courtesy of The US Department of Energy 17 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Pressure Diagnostics AUDITOR’S TOOLBOX Photos courtesy of The US Department of Energy 18 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Measuring Exhaust Fan Flow AUDITOR’S TOOLBOX Energy Conservatory Exhaust Fan Flow Meter with DG-700 Pressure & Flow Gauge Photos courtesy of The US Department of Energy 19 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Moisture Assessment AUDITOR’S TOOLBOX “Pin” or “Non contact” moisture meters Indoor/outdoor reads RH. Sling psychrometer. 20 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Circuit Testing & Tracing AUDITOR’S TOOLBOX Live wire tester, especially useful for determining if knob & tube wiring is still live. Circuit tracer determines which fuse/breaker controls which circuit. Tells auditor percent overload on circuit, among other outputs. 21 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Base Load Analysis AUDITOR’S TOOLBOX Indoor/outdoor thermometer, useful in measuring refrigerator/freezer compartment temperatures. Newer model watt meter BrultechKit60 with 1220B. Watt meter. 22 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Summary AUDITOR’S TOOLBOX • The field form keeps you focused. • A blower door is essential. • Infrared is convenient but can lead to false conclusions. • Good tools pay for themselves. • There are many specialized tools and tests available. • Don’t test simply for the purpose of testing! Test only when the result will give usable information. 23 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov