GroundMed On-Line Monitoring System Barcelona 21-02-2013 Andre Quintino Duarte Info All information available at: www.isr.uc.pt/~groundmed 1. DAQ - Data Acquisition System National Instruments cRIO 9074 NI 9217 NI 9871 NI 9219 or HEXIN converter. 1. DAQ - Data Acquisition System DAQ Brunata Thermal Meters Pyranometer Carlo Gavazzi Meters Humidity Sensor Indoor/Outdoor Temperature Sensors 1.1. DAQ System Coimbra DAQ System with display. 1.2. DAQ to DMS Server Septemes les Vallons, France DAQ System Oradea, DAQ Romenia System Coimbra, DAQ Portugal System Benedikt, DAQ Slovenia System Valencia, DAQ Spain System Barcelona, DAQ Spain System Padova, DAQ Italy System DAQ Athens, Greece System Internet Internet Internet Internet GroundMed WebSite Internet Internet Internet Internet DMS Server 1.2. DAQ to DMS Server Time 0 sec: var1; var2; var3; ...; var59 Time 15 sec: var1; var2; var3; ...; var59 Time 30 sec: var1; var2; var3; ...; var59 Time 45 sec: var1; var2; var3; ...; var59 1 minute Each cRIO must: - Make all measurements every 15 seconds; - After 4 measurements (1 minute) a sting of Data is created with the average of the 4 readings for each variable. 1.2. DAQ to DMS Server DAQ System average var1; average var2; average var3; ...; average var59 - Every 10 minutes, DAQ updates Data into DMS server; 1.2. DAQ to DMS Server DAQ System average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 average var1; average var2; average var3; ...; average var59 10 Minute Data 1.2. DAQ to DMS Server DAQ System 10 Minute Data DMS Server 1.2. DAQ to DMS Server DMS Server DAQ System 10 Minute Data 2. Software Installation 2.1. Software Configuration - 8 different demonstration sites Does this means 8 different software versions? 2. Software Installation 2.1. Software Configuration 2. Software Installation 2.2. Measuring Utility 2.3. New cRIO Software cRIO Software update v3.0 • Fix Carlo Gavazzi reading problem under some conditions; • NI-9871 for RS-485 bus is now supported in addition to the HEXIN Converter; • Fix some calculations. New Configuration Utility v3.0 New Measuring Utility v3.0 3. DMS Server What do we need? - Reliability; - Security; - Redundancy; - Large Disk Space; - Easy to expand system; - FTP Access; - MySQL Database; - Good WebHosting Uptime (> 99,9%). 3. DMS Server HP DL120 G7 Rack High Reliability Data Server - Intel Xeon 4-core processor; - Multiple Hard Disk Drives; - RAID 5 (Speed + Data Protection); - Modular Server. 3. DMS Server Data Base storage; Web Interface storage; Excel file 3. DMS Server 3.1. Access Levels Free Access GroundMed DataBase (Everyone can access to the real time web display) GroundMed WebSite Partial Access (Gound-Med partners access to the Excel file with all variables except the heat pump confidential information) Total Access + (Full access to Excel files. ISR only) 3.1. Access Levels 3.1.1. Free Access - No Login is required; - Everyone can access to the real time web display; - Visible variables only; - Access to all GroundMed Pilots. 3.1. Access Levels 3.1.2. Partial Access - Login is required (one for all pilot); - Real time web display with all allowed variable; - No access to Heat Pump confidential variables; - Excel file available for download; - Option between “Daily Values” or “Summary” 3.1. Access Levels 3.1.3. Full Access - Login is required (one for each pilot); - Real time web display with all variable; - Full access to Heat Pump confidential variables; - Excel file available for download. 4. Web Interface 4. Web Interface 4.1. DMS Input Status Pilots Sending data to DMS Server? Septemes les Vallons Yes, but miss formatted. Oradea Yes, need to update to cRIO v3.0 to fix CG readings. Coimbra Yes. Benedikt Yes, but with no communication from Landis and Gyr meters. Valencia Yes. Barcelona Yes, but no communication from RS-485 meters. Padova No. Athens No. 5. Further Development in Coimbra - Control Heat Pump working periods; Control Heat Pump Summer/Winter mode; Change Heat Pump setpoints; Control input/output Heat Pump valves; Charge/discharge Thermal Storage; Control Fan Coils (on/off). 5. Further Development in Coimbra NI 9472 - 8 Sourcing Digital Outputs; - 6 to 30V range. Finder Relay 20.21.9.024.4000 - 24V Coil Voltage; - 250V AC Rated Voltage. 5. Further Development in Coimbra Summer/Winter control. 5. Further Development in Coimbra Manual valve control. Thank You Andre Quintino Duarte