CPRI Bhopal - Deeparti Silicons

advertisement
DEEPARTI SILICONS
 Our Factory
 Deeparti Silicons
 Factory Area 10000 sq
ft
INTRODUCTION
 DEEPARTI SILICONS
 133-A, SECTOR –A, INDUSTRIAL
AREA, MANDIDEEP-462046
 Telephone: - 07480-403877,
mob. No. 9303131905
 E-mail.:-
deepartisilicons@yahoo.com
 We introduce ourselves as
manufacturers of CT windings,
CT, PT, and CT-PT Units indoor
& outdoor and are located at
Mandideep near Bhopal.
 We are very well versed in this
line and are more than 15 years
old, involved in the
manufacturer of Transformer
laminations, toroidal cores , ring
cores, cut core ,stepped
round/rectangular core, DG
cores etc., secondary winding of
cores for CT’s up to 400 kV, wall
shunt assembly for power
transformer tanks etc.
We have recently added a complete product range
for manufacture of CT, PT up to 33 kv (outdoor &
indoor) we are well equipped with all
manufacturing facility for CT/PT .We have inhouse set up for production of transformer
laminations, slitting line for manufacture toroidal
cores, winding of Toroidal cores, primary and
secondary winding of CT/ PT, heat treatment etc.
We have a full fledged set up of testing facility of
the highest accuracies .We have qualified / skilled
man power involved in manufacture, production,
quality assurance, testing of our product range.
Informatively, our CT/PT units have been type tested
with CPRI Bhopal. The relevant certificate will be
submitted.
We have been well accepted in terms of quality,
delivery, etc. by our customers including M/S BHEL,
M/S ABB LTD., M/S Siemens, and M/S. Areva among
others.
May we request you to consider us as a source to
meet your Transformer Laminations, Toroidal cores,
Ring Core, Secondary windings, CT/PT requirement
and forward your valued enquiry enabling us to
initiate the process for business development.
Product
We offer comprehensive range of industrial products these are cost efficient, highly
durable and have long service life. Any tailor-made specification in the product can be
incorporated based on customer’s requirements. Our industrial products are:•
CT-PT COMBINED UNIT :- combined CT-PT units up to 33kV , this is a
system having 3 nos. Of CT’s& PT’s housed in
metallic enclosure live and earth parts are
insulated by porcelain insulators. This unit
used for 3 phase 4 wire system.
These units are hermetically sealed to
ensure non ageing of insulation.
•
CURRENT TRANSFORMER:- It is a measuring device for metering and
protection system.
•
POTENTIAL TRANSFORMER:- PT is used to step down the system voltage
to Measureable voltage of 110/63.5 V
Features
Type
Related voltage
Primary current
Secondary current
Ratio
Accuracy/Burden
Voltage factor
:- Outdoor/indoor
: - up to 33kV
:- 5A to 2000A
:- 5A & 1A
:- as per requirement
:- as per requirement
:- 1.2 cont.& as per requirement
Manufacturing facilities
We are infrastructurely well equipped with modern manufacturing,
testing, quality assurance facilities, ensuring smooth flow of manufacturing
process. Our professionally trained manpower takes due care of quality norms
set by our organization. Manufacturing facilities are:•CT coil winding machine
•PT coil winding machine
•Resin cast vacuum plant -20kg( Toshniwal make)
•VACCUM IMPREGNATION PLANT oil-200 letters.(Toshniwal make)
•Vaccum impregnation plant varnish-100 letters.(Toshniwal make)
•Curing oven
•Slitting machine( for Laminations)
•Toroidal Core winding machine
•Annealing furnace( up to 1250 degree)
•CO2 welding machine
•Arc welding
•Drilling machine
•Surface Grinder
•Lathe & milling machine
•Shearing machines
•Power presses 60 tons to 5 tons
•All required handling equipment- over head crane etc.
Testing facilities
•Accuracy testing bridge for CT & PT of ELTEL, Bangalore. (2 units)
• Standard CT 5A & 1A( make Sev electrical)ratio :- up to 1200 A
•Standard PT ratio:-33-11-6.6-3.3kV/110-63.5V
•High voltage test set-0 to 100 kV(make Automatic electric)
•CT core test set
•High current injection source up to 2000A
•High voltage injection source up to 33 kv
• High frequency voltage generator 200 Hz(DVDF)
• Resistance meter(rishabh)
•Multimeter(fluke/rishabh)
•PT Burden box(up to 150 VA)
•CT Burden Box( up to 40 VA)
•Meger meter
•Ratio meter( Eltel)
•True RMS. Meter( fluke)
•Low voltage meter-0 to 5 kv
•All related standard measuring equipment
Details Of Type Tests Conducted
1)33 KV CT-PT UNIT CTR:-400-200/5A
2) 33 KV CT-PT UNIT CTR:-200-100/5A
3) 11 KV CT-PT UNIT CTR:- 300-150/5A
4) 11 KV CT-PT UNIT CTR:- 200-100/5A
5) 11 KV CTR:- 300-150/5-5A
6) 11 KV CTR:-200-100/5-5A
7)11 KV CTR:-200-100/5-5A
8) 33 KV CTR:- 300-150/5-5A
9) 33 KV CTR:-200-100/5-5A
Sl.
No
1
Name of Test
Place where tested
Test Report no.
TEST REPORT DATE
STC TEST
CPRI, BHOPAL
2
IMPULES TEST
CPRI, BHOPAL
3
TEMPERATURE RISE
TEST
CPRI, BHOPAL
S2121073
S2121074
S2121075
S2121076
S2121077
2012/STL/1108
2012/STL/1107
2012/STL/1092
2012/STL/1093
2012/STL/1094
2012/STL/1095
2012/STL/956
2012/STL/955
2012/STL/954
2012/STL/953
2012/STL/972
2012/STL/972
DATE-10-01-2013
DATE-10-01-2013
DATE-10-01-2013
DATE-10-01-2013
DATE-10-01-2013
DATE-16-10-2012
DATE-16-10-2012
DATE-17-10-2012
DATE-17-10-2012
DATE-17-10-2012
DATE-16-10-2012
DATE-05-09-2012
DATE- 05-09-2012
DATE-10-09-2012
DATE- 10-09-2012
DATE-13-09-2012
DATE-13-09-2012
ATOSMOSPHHERE
 Eco friendly
atosmophere
GARDEN
 Garden
CUT CORE
 Cut core
 Used in MVR coils
 Dim: Material: M4
Lamination
CUT CORE
 Two halves of cut core
 Complete taped core
with earth strip
IVT COIL
 IVT coil (Intermediate
voltage transformer)
used in 220 KV CVT
assembly.
IVT COIL
 IVT coil used in CVT
assembly
IVT CORE
 IVT core assembly
IVT CORE
 IVT core assembly
IVT ASSEMBLY
 IVT core assembly with
coil used in EMU
assembly for 220 KV
cvt
D.G.R.C.
 Distributed gap
rectangular core
D.G.R.C.
 Distributed gap core
 The gaps are seen
RECTANGULAR CORE
 Rectangular core
 Dim: Used in instrument
transformer
RECTANGULAR CORE
 Bare rectangular core
 Taped rectangular core
with earthing strip
RECTANGULAR STEPPED CORE
 Rectangular stepped
core
 This has a better space
factor
STEPPED CORE
 Rectangular stepped
core with round
corners
ROUND CORNER
 Rectangular round
corner core
RING STEPPED CORE
 Round stepped core
 Dim:-
RING STEPPED CORE
 Round stepped core
 Dim:-As per
requirment
STEPPED CORE
 Rectangular round
corner stepped core
RING CORE
 Round corner stepped
core
STEPPED RING CORE
 Round core stepped
core
33 KV CT-PT UNIT
11KV CT-PT UNIT
CURRENT TRANSFORMER
VOLTAGE TRANSFORMER
SECONDARY WINDING
SHUNT WALL FOR POWER
TRANSFORMER
THANK YOU