Primary Sensing Elements and Transducers 755 piezo-electrical crystal and so on. In all cases, however, the electrical output is measured by standard methods, giving the magnitude of the input quantity in terms of an analogous output. 25.7 ELECTRIC TRANSDUCERS The art of electrical measurements has been chiefly used for measurement of electrical quantities but its value in making measurements of non 25.6 TRANSDUCERS An electronic instrumentation system consists of a number of comnponents to perform a measurement and record its results. As explained earlier a generalized measurement system consists of three major components. () an input device, (ii) a signal conditioning or processing device, and (iii) an output device. The input device receives the measurand or the quantity under measurement and delivers a propor tional or analogous electrical signal to the signal conditioning device. Here the signal is amplified, attenuated, filtered, modulated, of otherwise modified in format acceptable to the output device. The input quantity for most instrumentation systems is a "non-electrical quantity'". In order to use electrical methods and techniques for measurement, manipulation or control, the non-electrical quantity is generally converted into an electrical form by a device called a "transducer". We can define a transducer as a device which, when actuated transformsenergy from one form to another. The broad definition of a transducer includes, for example, devices which convert mechanical force into an electrical signal. These devices form a very large and important group of transducers commonly used electrical quantities in this new era of automation is rapidly growing. In order to measure non-electrical quantities a detector is used which usually converts the physical quantity into a displacement. This displacement actuates an electric transducer, which acting as a secondary transducer, gives an output that is electrical in nature. The electrical quantity so produced is measured by standard methods used for electrical measurements. The result (electrical output) gives the magnitude of the physical quantity Or condition being measured. The electrical signal may be a current or a voltage or a frequency and production of these signals is based upon electrical effects which may be resistive, capacitive, inductive etc. in nature. The first stage of a measurement system may simply be called a transducer stage instead of detector transducer stage by redefining a transducer. A trans ducer, in general form, may be defined as a device which converts energy from one form to another. However, this definition has to be restricted, many a time especially in the field of electrical tation. Keeping this restriction in view, a instrumen may be defined as a device which convertstransducer a physical quantity or aphysical condition into an electrical signal. Another name fora transducer is pick up. 25.7.1 Advantages of Electrical Transducers There are a number of transducers which trans a variety of physical form in industrial instrumentation area. The instrumen and phenomena into electrical signals. The quantities for reasons transforming a tation engineers and technologists are therefore physical into phenomenon electrical form are primarily concerned with this area of instrumentation. numerous. The of advantages converting physical Many other physical parameters such as heat, intensity into quantities analogous electrical quantities are : of light, flow rate, liquid level,humidity and pH value () Electrical may also be converted into electrical form by means of amplification and attenuation can transducers. These transducers provide an output signal when stimulated by a mechanical or non-mechanical input : a photoconductor converts light intensity into change of resistance, thermocouple converts heat energy into electrical voltage, a force produces a change of resistance in a strain gauge, an acceleration produces a voltage in a be done easily and that too with static devices. (ii) The mass-inertiaj effects are fact, when dealing with electrical or minimised. In electronic signals, the inertia effects are due to electrons which have negligitble mass. In many situations, we do not come across mass or inertia problems at all. (iii) The effects of friction are minimised. 25 /56 Electrical and Electronic Megsurements and Instrumentation (iv) The electrical or electronic systems can be controlled with a very small power level. (v) The electrical output can be easily used, trans mitted and processed for the purpose of measurement. (vi) Telemetry is used in almost all sophisticated measurement systems. The entire aerospace research and development is based upon telemetry and remote control. The ever-enlarging field of radio monitoring in space research has left us with no alternative but to rescrt to electronic means. This completely eliminates the data transmission through mechanical means and hence electrical arnd electronic principles have to be employed for these conditions. The remote indication or recording is an essential part of modern day instrumentation technology. (vi) There has been an explosive development in the field of electronic components and devices. This development is on account of the fact that electronic devices are very amenable to miniaturization. Components which are compact, have always an, advantage. Miniaturization on account of use of ICs (integrated Circuits) has completely revolutionised the field of instrumentation. In short, it can be said that the reasons for transforming a physical phenomenon into electrical form is that the electrical output can be easily used, transmitted and processed for the purposes of measurement. Modern digital computers make the use of these transducers absolutely essential. When the definition of transducer is confined to a device that covers the entire detector transducer stage, wherein the transducer converts anon-electrical quantity into an analogous electrical signal, the trans ducer may be thought of consisting of two important and closely related parts. These two parts are: A Sensing Element, and 25.8 CLASSIFICATION OF TRANSDUCERS The transducers can be classified () on the basis of transduction form used, .() as primary and secondary transducers, (i) as passive and active transducers, (iv) as analog and digital transducers, and (v) as transducers and inverse transducers. 25.8.1 Classification based upon Principle of Transduction The transducers can be classified on the basis of principl of transduction as resistive, inductive, capacitive etc. depending upon how they convert the input quantity into resistance, inductance or capaci tance respectively. They can be classified as piezo electric, thermoelectric, magnetorestrictive, electro kinetic and optical. Table 25.2 lists the classification of transducers based upon principle of transduction. 25.8.2 Primary and Secondary Transducers Let us consider the case of a Bourdon's tube as shown in Fig. 25.26. The Bourdon tube acting as a primary detector senses the pressure and converts the pressure into a displacement of its free end. The displacement of the free end moves the core of a linear variable differential transformer, (L.V.D.T.) which produces an output voltage which is proportional to the movement of the core, which is proportional to the displacement of the free end which in turn is proportional to the pressure. Thus, there are two stages of transduction, firstly the pressure is converted into a displacemnent by Bourdon tube then the displacement, is converted into an analogous voltage by L.V.D.T. The Bourdon tube is called a "Primary Transducer" while the L.V.D.T. is called a "Secondary Transducer". Transduction Element. Free end In addition, there may be many other auxiliary parts, such as amplifiers and other signal processing Cord equipmernt, power supplies, calibrating and reference Pulley sources, and mechanical mounting features. 1. Sensing or Detector Element. A detector or a voltage Output sensing element is that part of a transducer which element must be closely related to the physical phenomenon. 2. Transduction element. A transduction element transforms the output of a sensing element to an electrical output. The transduction element, in a way, acts as a secondary transducer. tube Sec. windings responds to a physical phenomenon or a change in a physical phenomenon. The response of the sensing Bourdon Fixed Core end 0000 Primary winding Pressure L.V.D.T. semt Fig. 25.26 Measurement of pressure using Bourdon tube an L.V.D.T. (Example of and transducers). primary Secondary Primary Sensing Elements and Transducers Table 25.2 757 Types of Electrical Transducers Electrical parameter and class of trarisducer Principle of Operaton Iypical applications Passive transducers (externally powered) Resistance Potentiometer device Resistance strain gauge Pirani gauge or hot wire meter Resistarnce thermometer Thermistor Positioning of the slider by an external force varies the Pressure, displacement. resistance in a potentiometer or a bridge circuit. Resistance of a vire or semiconductor is changed by elongation Force, torque, displacement. Resistance of heating element is varied by convection cooling of Gas flow, gas pressure. or compression due to extermally applied stress. astream of gas. Resistance of pure metal wire with a large positive tempe rature co-efficient of resistance varies with temperature. Temperature, radiant heat Resistance of certain metal oxides with negative temperature Temperature, flow Resistance hygrometer coefficient of resistance varies with temperature. Resistane of aconductive strip changes with moisture content. Photoconductive cell Relative humidity. Resistance of the cell as a circuit element varies with incident Photosensitive relay. light. Capacitance Variable capacitance Distance between two parallel plates is varied by an externally Displacement, pressure. pressure gauge applied force. Capacitor microphone Sound pressure varies the capacitarnce between a fixed plate Speech, music, noise. and a movable diaphragm. Dielectric gauge Variation in capacitance by changes in the dielectric or Liquid level, thickness. Magnetic circuit Self-inductance or mutual inductance of a.c. excited coil is transducer varied by changes in the magnetic circuit. Pressure, displacement. Reluctance pick up Reluctance of the magnetic circuits is varied by changing the dielectric constant. Inductance Differential transformer Eddy current gauge Magnetostriction gauge position of the iron core of coil. The differential voltage of two secondary windings of a Pressure, displacement, vibrations, position. Pressure, force, transformer is varied by positioning the magnetic core through displacement, position an externally applied force. Inductance of a coil is varied by the proximity of an eddy Displacement, current plate. thickness. Magnetic properties are varied by pressure and stress. Force, pressure, sound. A potential difference is gernerated across a semiconductor plate Magnetic flux, current, Voltage and Current Hall effect pickup (germanium) when magretic flux interacts with an applied Current. lonization chamber Electron flow induced by ionization of gas due to power. radio-active radiation. Particle counting, Photoenmissive cell Electron emission due to incident radiation upon Light and radiation. Photomultiplier tube Secondary electron emission due to incident radiation on Thermocouple and thermopile metals or semiconductors when that junction is heated. radiation. Moving coil generator Motion of a coil in a magnetic field generates a voltage. Velocity, vibrations. Piezoelectric pickupP crystalline materials, such as quartz. ration, pressure changes. A voltage is generated in a semiconductor junction device Light meter, solar cell. Photovoltaic photoemissive surface. radiation. Light and radiation, photosensitive cathode. photosensitive relays. Self-generating transducers (no external power) An emf is generated across the junction of two dissimilar Temperature, heat flow, An emf is generated when an external force is applied to certain Sound, vibrations, accele when radiant energy stimulates the cell. 25 758 Electrical and Electronic Let us take another example which is the case of measurement of a compressive force with the help of a load cellin conjunctionwith strain gauges as shown in Fig. 25.27. (Load cells and strain gauges are explained later in this chapter.) Force Measurements and Instrumentation Transducers 25.8.3 Passive and Active according to Transducers may be classified whether they are passive or active. Passive transducers 1. Passive Transducers. an derive the power required for transduction from part of the auxiliary power source. They also derive physical the power required for conversion from known as quantity under measurement. They are also of "externally powered transducers". Typical examples inductive and passive transducers are resistive, capacitive transducers. A typical example of a passive Strain transducer is a displace POT' which is used for measurement of by a powered transducer ment. A 'POT' is a resistive is 'POT This source voltage e, as shown in Fig. 25.28. used for measurement of linear displacement x,. gauges Load cell Force Wiper Fig. 25.27 Force measurement with load cell R, and strain gauges. The load cell is a short column or a strut with resistance wire strain gauges bonded to it. The measurand, in this case, is a force and is applied to the column thereby producing strain. The force is first detected by the column and is converted into strain which is a mechanical displacement. The higher the force, the higher is the strain and thus the input signal (force) is converted into an analogous output (strain). This strain changes the resistance of the strain gauges. Fig. 25.28 Linear potentiometer (POT), a passive transducer. Suppose L is the total length of potentiometer whose total resistance R, The input displacement is x,: :.Output voltage Thus we have an output which is a change in the value of resistance i.e., electrical in form. Hence, in this case it takes two processes to convert an input into an analogous output. The first process involves con version of force into mechanical displacement which is done by the column, while the second process involves conversion of mechanical displacement into change of resistance which is done by strain gauges. Thus we see that the force is detected by the column in the first stage and hence it is called a Primary Transducer. The output signal from the primary transducer is converted subsequently into a usable output by the strain gauges and therefore they are known as Secondary Transducers. In most of measurement systems, there is a suitable working combination wherein a Mechanical device acts as a primary detector transducer and the electrical device acts as the secondary transducer with mechanical displacement serving as intermediate signal. the L or In the absence of external power, the transducer cannot work and it hence is called a passive transducer. 2. Active Transducers. Active transducers are those which do not require an auxiliary power source to produce their output. They are also known as self generating type since they develop their own voltage or current output. The energy required for production of output signal is obtained fronm the physical quantity being measured. Velocity, temperature, light and force can be transduced with the help ofintensity active transducers. These transducers include tachogenerators, thermo couples, photovoltaic cells and piezoelectric crystals. Consider the case of a piezoelectric crystal used for measurement of acceleration as shown in Fig. 25.29 The crystal is sandwiched between two metallic electrodes, and the entire sandwich is fastened to a base which may be the floor of a rocket. A fixed mass is placed on the top of the sandwich. Primary Sensing Elements and Transducers 759 Mass Metallic electrodes Crystal Base Output voltage Fig, 25.30 5-digit scale for digital indication of linear position of a movable object. Direction of acceleration Fig. 25.29 Piezo-electric acceleration crystral measuring transducer. - an active The property of the crystals is that when a force is appliedpiezo-electric to them, they. produce an output voltage. The mass exerts a certain force on account of acceleration on the crystal due to a voltage is generated. The acceleration is appliedwhich to the base, due to which the mass produces a force. The mass being fixed, the force is proportional to acceleration. The voltage output is proportional force and hernce is proportional to acceleration (the mass being fixed). It should be noted from above that this transducer called "accelerometer" which converts acceleration into electrical voltage does not need any auxiliary power source to convert a physical phenomenon (accele ration in this case) to an electrical output (voltage in this case) and therefore is an active transducer. 25.8.4 Analog and Digital Transducers The transducers can be classified on the basis of the output which may be a continuous function of time or the output may be in discrete steps. 1. Analog Transducers. These transducers convert the input quantity into an analog output which is a continuous function of timne. Thus a strain gauge, an L.V.D.T., a thermocouple or a thermistor may be called as "Analog Transducers" as they give an output which is acontinuous function of time. 2. Digital Transducers. These transducers convert the input quantity into an electrical output which is in the form of pulses. Glass scales can be read optically by means of a light source, an optical system and photocells. Metal scales are scanned by brushes making electrical contact with individual tracks. The, resolution depends upon the digits comprising the binary number and is 1/2n of full scale where n is the number of digits. 25.8.5 Transducers and Inverse Transducers There is a strong association of control with measurement. The basic requirement for control of physical quantities such as position, speed, temperature, pressure and flow rate in ah industrial planet is the ability to measure these quantities. The control action is only possible if the physical quantity can be measured. For examnple, in a position control system called "servomechanism", it is desired to control the position of a shaft. This requires an accurate method for measurement of the shaft position in order that its position be accurately controlled. Further, if it controlled manner, then the position measuring device must be able to measure shaft position for rapid changes i.e., the device must have a fast dynamic response. Figure 25.31 shows the block diagram of closed loop control system. The controlled (output) quantity is usually a non electrical quantity. The control action is through an input quantity that corresponds to the is desired that the shaft be accelerated in a Error electrical (input) point i Reference network ransparent areas on à glass scale or non-conducting Controlled quantity l Actuator I (amplifier) As the binary system uses only two symbols 0 and 1 it can be easily represented by opaque and Feed forward I Measuring I 1 instrument or transducer and, conducting areas on a mnetal scale. A scale constructed to show the linear position on a movable Electrical units or signals object and having five digits is shown in Fig. 25.30. The complete binary number denoting position is Mechanical units or signals obtained by scanning the pattern across the scale at a stationary index mark. 25 Fig, 25.31 Feedback control system for control of non-electrical quantities. +(non-electrical) ) 760 Electrical and Electronic desired output (non-electrical quantity). The input quantity called reference input is usually an electrical quantity. The controlled quantity is measured and Error point Reference quantity r(0) (non-electrical Measurements and Instrumentation Feed Indication ofmeasured (electrical) quantity forward Transducer ’c() network (amplifier) converted into an analogous quantity by transducers which form the feedback loop. The loop input quantity (electrical in nature) is compared with the electrical quantity proportional to the output in a Inverse transducer comparator. In case, the two are not equal an error signal is produced. This error signal is amplified and applied to an actuator in the forward path, which Electrical units or signals Mechanical units or signals corrects the output quantity till the output quantity reaches the desired level. 1. Transducers. A transducer can be broadly defined as a device which converts a non-electrical quantity into an electrical quantity. 2. Inverse Transducers. An inverse transducer is defined as a device which converts an electrical quantity into a non-electrical quantity. It is a precision actuator which has an electrical input and a low power non-electrical output. A piezoelectric crystal acts as an inverse transducer because when a voltage is applied across its surfaces, it changes its dimensions causing a mechanical displacement. A current carrying coil moving in a magnetic field is also an inverse transducer because current carried by it is converted into a force which causes trans lational or rotational displacement. Many data indicating and recording devices are inverse trans Fig. 25.32 Feedback control system electrical feedback is It is evident that the operation of the similar for both control and measuring systems as regards accuracy and stability. levels through the actuator to directly determine the output quantity. Therefore, the actuator may have poor regulation without affecting the control action. The transducer and noise at the amplifier input largely determine theaccuracy of control. On the othei hard, the feedback measuring system involves use of tairly low power devices at the output. These devices curent into mechanical displacement. However, such devices which include instruments like indicating isiruments, pen recorders, oscilloscopes that convert die electrical signals to a mecharnical movement are most useful - application of inverse transducers is in feedback measuring systems. The development of transducers and inverse transducers, and the advantages gained through use of feedback -hasincreased their applications manifold and there is reason to believe that they will continue to grow in importance. A block diagram of a feedback control systems using inverse transducers is shown in Fig. 25.32 for comparison with the simple feedback control system shown in Fig. 25.31. In the measuring system, the output quantity (usually electrical in nature) is converted to a non-electrical form suitable for comparison with quantity to be measured (non-electrical form). The resulting error signal is usually transduced intb electrical form and ampl1fied to give output indication. essential performance requirements of transducing elements. The control systems handle relatively high power However, The The differences are in power level of the systems and the include placed at the output stage (data presentation stage) for control of quantities usinginverse transducer. ducers. An analog ammeter or voltmeter converts are called output transducers. Electrical quantities the indicator the inverse and inverse transducer. transducer essentially determines the characteristics of the system. The noise connected with the transducer and amplifier input stage is very important. 25.10 SUMMARY OF FACTORS INFLUENCING THE CHOICE OF TRANSDUCERS In the following parts of this chapter, an attempt has been made to give the details and applications of the transducers for measurement of different physical quantities. It will be realised that there are many ways for measurement of a physical quantity, and in many cases, there is no best way. The transducers and the methods used may depend upon the instrumentation already available and also on the experience of the user. Unfortunately most transducers are not sensitive to just one quantity. If measurements are to be made under conditions where there is likelihood of two or more input quantities influencing the transducer, it is desirable to select a transducer which is sensitive to the desirable quantity and insensitive to the unwanted quantity. If this is not possible, ways and means should be found to eliminate or compensate for the effects of the unwanted input quantity. The following is the summary of the factors influencing the choice of atransducer for measurement of a physical quantity. 766 Electrical and Electronic Measurements and 1.Operating Principle. The transducers are many a times selected on the basis of operating principle used by them. The operating principles used may be resistive, inductive, capacitive, optoelectronic, piezo electric etc. 2. Sensitivity. The transducer must be sensitive enough to produce detectable output. 3. Operating Range. The transducer should maintain the range requirements and have a good resolution over its entire range. The rating of the transducer should be sufficient so that it does not breakdown while working in its specified operating range. 4. Accuracy. High degree of accuracy is assured if the transducer does not require frequent calibration and has a small value for repeatability. It may be emphasised that in most industrial applications, repeatability is of considerably more importance than absolute accuracy. 5. Cross sensitivity. Cross sensitivity is a further Instrumentation work under its temperature range. It should be able to in corrosive environments (if the application so requires), should be able to withstand pressures and shocks and other interactions to which it is subjected to. 10. Insensitivity to Unwanted Signals. The transducer should be minimally sensitive to unwanted signals and highly sensitive to desired signals. both 11. Usage and Ruggedness. The ruggedness transducer of mechanical and electrical intensities of versus its size and weight must be considered while selecting a suitable transducer. 12. Electrical aspects. The electrical aspects that need consideration while selecting a transducer include the length and type of cable required. Attention also must be paid to signal to noise ratio in case the transducer is to be used in conjunction with amplifiers. Frequency response limitations must also be taken into account. 13. Stability and Reliability. The transducer should exhibit a high degree of stability to be actual quantity is being measured is in one plane and the transducer is subjected to variations in another plane. More than one promising transducer design has operative during its operation and storage life. Reliability should be assured in case of failure of transducer in order that the functioning of the instrumentation system continues uninterrupted. 14. Static Characteristics. Apart from low static had to be abandoned because the sensitivity to error, the transducers should have a low non-linearity, variations of the measured quantity in a plane perpendicular to the required plane has been such as to give completely erroneous results when the transducer has been used in practice. 6. Errors. The transducer should maintain the low hysteresis, high resolution and a high degree of factor to be taken into account when measuring mechanical quantities. There are situations where the repeatability. The transducer selected should be free from load alignment effects and temperature effects. It should not need frequent calibration, should not have any expected input-output relationship as described by its component limitations, and should be preferably transfer function so as to avoid errors. small in size. 7. Transient and Frequency Response. The transducer should meet the desired time domain specifications like peak overshoot, rise time, settling time and small dynamic error. It should ideally have a flat frequency response curve. In practice, however, there will be cutoff frequerncies and higier cut off frequency should be high in order to have a wide bandwidth. 8. Loading Effects. The transducer should have a high input impedance and a low output impedance to avoid loading effects. 9. Environmental Compatibility. It should be assured that the transducer selected to work under specified environmental conditions maintains its input-output relationship and does not break down. For example, the transducer should remain operable Primary Sensing Elements and TransdUcers 25.19 785 RESISTANCE THERMOMETERS The resistance of a conductor changes when its temperature is changed. This property is utilized for measurement of temperature. The variation of resistance R with temperature T(°K) can be represented by the following relationship for most of the metals as: high temperature applications as it is extremely brittle and difficult to work. Copper is used occasionally as an RTD element. Its low resistivity forces the element to be longer than the platinum element, but its low linearity and low cost make it an economical alternative. Its upper limit of temperature is about 120°C. R= R(1+ a,T+a,T+.t a,T"+...) ...(25.72) Connecting leads (4) where R = resistance at temperature T =0 and a ag.a3.. a, are constants. The resistance thermometer uses the change in electrical resistance of conductor to determine the temperature. The resistivity of metals showed a marked Mounting dependence on temperature was discovered by Sir Humphry Davy. A few years later Sir William Siemens preferred the use of platinum as an elemernt in the resistance thermometer. His choice proved most propitious, as platinum is used to this day as the primary element in all high accuracy resistance thermometers. In fact, the platinum resistance temperature detector (PRTD) is used today as an interpolation standard fromn oxygen point (-182.96°C) to antimony point (630.74°) Platinum is especially suited for this purpose, as it can withstand high temperatures while maintaining excellent stability. As a noble metal, it shows limited susceptibility to contamination. Allmetals produce a positive change in resistance with temperature. This, of course, is the main function of an RTD. The system error is minimized when the nominal value of RTD is large. This implies a metal with a high value of resistivity should be used for RTDs. The lower is the resistivity of the metal, the more material we will have to use. The requirements of a conductor material to be used in RTDs are : () The change in resistance of material per unit change in temperature should be as large as possible. (ii) The material should have a high value of resistivity so that minimum volume of material is used for the construction of RTD. (ii) The resistance of materials should have a continuous and stable relationship with temperature. threads Lead supports Sheath Element Fig. 25.62 Industrial platinum resistance thermometer. The most comnon RTDs are mnade of either platinum, nickel or nickel alloys. The economical nickel wires are used over a limited temperature range. They are quite non-linear and tend to drift with time. For measurement integrity, platinum is the obvious choice. The common values of resistance for a platinumn RTD range from:10 2 for the bird cage model to several thousands ohm for the film RTD. The single most common value is 100 2 at 0°C with a resistance temperature co-efficient of 0,00385/°C. The more chemically pure platinum wire has a esistance temperature co-efficient of 0.00392/°C. The construction of an industrial type of platinum RTD is shown in Fig. 25.62. The characteristics of various materials used for resistance thermometers are plotted in Fig. 25.63. Metals commonly used for resistance thermo meters are listed in Table 25.6 along with their salient properties. An examination of the resistánce versus Gold and Silver are rarely used, for construction of RTDs on account of their low resistivities. Tungsten Curves are has relatively a high resistivity, but is reserved for temperature spans are considered, the linearity is temperature curves bf Fig. 25.63, shows thát the nearly linear. If, fact, when only short 25 Electrical and Electronic 786 200° 0 600° 400° The reason for using e as the fractional slope of same resistance-temperature curve 1s that this 800°C 5 the same constant be used for conductors having value of material with different dimensions. The resistance and can be found from the value of general, temperatures as shown in 25.64. In Copper Nickel Measurements and Instrumentotion 1 3 R -x(slope at ,) Platinum R 1 8, -Ra ..(25.74) 10 0 400° 0 600° 800° Resistance, R(S2) 1000°K Temp. Fig. 25.63 Characteristics of materials used for resistance thermometers. more evident. This fact is employed to develop approximate analytical equations for resistarnce versus temperature for a particular metal. + + Table 25.6 Metals Used for Resistance Thermometers Metal Resistance Temperature temperature Tange °C Co-efficient Platinum 0.39 Copper 0.39 40 20 Melting point 80 60 100 120 Temperature, °C Fig. 25.64 Astraight line representing an approximate Min Max - 260 110 1773 180 1083 Example 25.21 Find the linear approximation between 300 1435 1000 3370 30°C to 60°C using the resistance-temperature curve as shown in Fig. 25.64. Nickel 0.62 - 220 Tungsten 0.45 -200 relationship between resistance R and temperature 0. Solution. We have 25.19.1 Linear Approximation develop an 'equation for a straight line which 0, =30°C and 0, =60°C Mean temperature O, =(30 +60)/2 = 45°C. over a specified span. Figure 25.64 shows a curve of variation of resistance with temperature °C. Here astraight line has been drawn between the From Fig. 25.64, we have: Resistance at 30°C, A linear approximation means that we may approximates the resistance versus temperature curve points of the curve which represent 0,°C and 0,°C =4.8 2, resistance at 60°C with ,°C representing the mid point temperature. The equation of this straight line is the linear approximation of the curve from 0,°C to 6,°C. The equation of the straight line is written as: =6.2 S2 and resistance at 45°C Ry=Ro, (1+4,, 48) with < <e, ...(25.73) Ro, = 5.5 n From Eqn. 25.74, 1 X Re, -Ro where Ro = approximate resistance at 9°C;L, R = approximate resistance at 0, °C;2, AÔ = 0-0, =change in temperature ; °C, = resistance temperature co-efficient at temperature O,°C; /°C 1 6.2 x 4.8 5.5 60-30 =0.0085°C Hence, the linear approximation is : RÍ =5.5[1+0.0085 (0 -45)]2 Primary Sensing Elements and Transducers 787 25.19.2 Quadratic Approximation A quadratic approximation of the resistance temperature curve is more accurate representation of 2. Quadratic Expansion : The resistance R, at any temperature °C is given by : Ry =Ro, l1+ a, d0 +a,(Ae)1 the curve over a limited range of temperature. The We can find the quadratic terms, by forming two quadratic approximation relationship includes both a equations using two points about the mean linear term as in Eqn. 25.73 and an addition has a term which varies as the square of the difference in temperature , = 115°C temperature. The approximation is written as : where R, = Ra, (l+a, 48+ a, (40)] ..25.75) a, = linear fractional change in resistance ;/°C and a, = quadratic fractional change in resistance, /(°C) Values of a, and a, are found from tables and graphs as indicated in the example given below by using values of resistance and temperature at three different points. Two equations are formed and values We have, = 598.48Q at , =115°C. Now using 100Cand 130°C as the two points, we have: 573.40 =589.48 [1 + a,(100115) +a, (100 -115)') 605.52 =589.48 [1 +a, (130 115) +a, (130 -115)') From above, we have, a, =1.823 x10-8/°C a, =-0.22 x10-/(°c? and Hence, of a, and a, are calculated from these. R, =589.48(1 + L823 x10 (0- 115) 0.22 x10 (0- 115)2] 2 Example 25.22 Use the following values of resistance Exanple 25.23 A platinum thernometer has a versus temperature for an RTD to find the linear and quadratic approximations of resistance between 100°C and 130°C about a mean temperature of 115°C. Temperature, °C Resistance Q 90 562.66 95 568.03 100 573.40 105 578.77 110 584.13 115 589.48 120 594.84 125 600.18 130 605.52 Solution. 1. Linear Expansion : Given : e, =100°C 8, =130°C e, =115°C Ra, = 573.40 2, Rp. =605.52 S2, Ra. = 589.48 2 resistance of 100 SQ at 25°C. (a) Find its resistance at 65°C if the platinum has a resistance temperature co-efficient of 0.00392/°C. (b) If the thermometer has a resistance of 150 2, calculate the temperature. Solution. (a) Using the linear approximation, the resistance at any temperature °C, is R = Ro, [1+ ag, 40] .. Resistance at 65°C is, Res =100[1+0.00392 (65 -25)] = 115.68 2 (b) Suppose 9 is the unknown temperature, 150= 100(1 +0.00392 (0 -25)] 0=152.55°C Example 25.24 A copper resistor at 20°C is to used to indicate the temperature of bearings of a machine. What resistance should not be exceeded if the maximum bearing temperature is not to exceed 150°C ? The resistance temperature co-efficient of copper is 0.00393/°C at 20°C. From Eqn. 25.74, 1 Ro, -Ra, 0, -0, 1 605.52 -573.40 598.48 130 -100 = 0.00182 /°C .:. The linear approximation is: Ro = 598.48(1 +0.00182 (0 -115)]2 Solution. The value of resistance in case the temperature is not to exceed 150°Ccan be calculated as under. K1s0 = 10[1+0.00392(150 -20)] =15.11 2 Example25.25 Atemperature alarm unit with atime constant of 120 s is subjected toa sudden rise of temperature of 50°C because of fire. If an increase of 30°C is required to actuate the alarm, what will be the delay in sudden temperature inCrease ? 25 788 Electrical and Electronic Measurements and Glass coated bead Instrumentaties Glass Leads Leads (b) Probe (a) Bead Lead 25.20 THERMISTORS Thermistor is a contraction of a term "thermal resistors". Thermistors are generally composed of (c) Disc semi-conductor materials. Although positive tempe rature co-efficient of units (which exhibit an increase in the value of resistance with increase in temperature) are available, most thermistors have a negative coefficient of temperature resistance i.e. their resistance decreases with increase of temperature. The negative temperature coefficient of resistance can be as large as several percent per degree celsius. This allows the thermistor circuits to detect very small changes in temperature which could not be observed with an (a) Rod Fig. 25.65 Different forms of construction of thermistors. 25.20.2 Resistance-Temperature Characteristics of Thermistors RTD or a thermocouple. In some cases the resistance of thermistor at room temperature may decrease as The mathematical expression for the relationship much as 5 percent for each 1°Crise in temperature. This high sensitivity to temperature changes makes between the resistance of a thermistor and absolute temperature of thermistor is: thermistors extremely useful for precision tempe ...(25.76) rature measurements control and compensation. Thermistors are widely used in applications which involve measurements in the range of -60°C to 15°C. The resistance of thermistors ranges from 0.5 2 to 0.75 MQ. Thermistor is a highly sensitive device. The price to be paid off for the high sensitivity is in terms of linearity. The thermistor exhibits a highly non linear characteristic of resistance versus temperature. 25.20.1 Construction of Thermistors Thermistors are composed of sintered mixture of metallic oxides such as manganese, nickel, cobalt, copper, iron and uranium. They are available in variety of sizes and shapes. The thermistors may be in the form of beads, rods and discs. Some of the commercial forms are shown in Fig. 25.65. A thermistor in the form of a bead is smallest in size and the bead may have a diameter of 0.015 mmn to 1.25 mm.Beads may be sealed in the tips of solid glass rods to form probes which may be easier to mount than the beads.Glass probes have a diameter of about 2.5 mm and a length which varies from 6 mm to 50 mm. Discs are made by pressing material under high pressure into cylindrical flat shapes with diameters ranging from 2.5 mm to 25 mm. where Rry = Iesistance of the thermistor at absolute temperature T;°K Rrz and resistance of the thermistor at absolute temperature T,;°K B=a constant depending upon the material of thermistor, typically 3500 to 4500 °K The resistance temperature characteristics of a typical thermistor are given in Fig. 25.66. The resistance temperature characteristics of Fig. 25.66 shows that a thermistor has a very high negative temperature co-efficient of resistance, making it an ideal temperature transducer. Figure 25.66 also shows the resistance temperature characteristics of platinum which is a commonly used material for resistance thermometers. Let us compare the characteristics of the two materials. Between - 100°C and 400°C, the thermistor changes its resistivity from 10° to 10Qm, a factor of 10,while platinum changes its resistivity by afactor of about 10 within the same temperature range. Thisexplains the high sensitivity of thermistors for measurement of temperature. Primary Sensing Elements and Transducers 789 narrower temperature range in order to approach the 10 accuracy achieved by Steinhart-Hart equation. Another relationship that can be conveniently used for resistance-temperature curve of thermistors is : Thermistor Sm Resistivity, 10² ..(25.80) R = aR,exp(b/T) where, R,, R = resistance of thermistor at tempe rature T°K and ice point respectively. 102 104 l0-6 Platinum 10-8 - 100 100 200 300 400 500 Temperature °C Fig. 25.66 Resistance-temperature characteristics of atypical thermistor and platinum. The characteristics of thermistors are no doubt non-linear but a linear approximation of the resistance-temperature curve can be obtained over a smallrange of temperature. Thus, for a limited range of temperature, the resistance of a thermistor varies as given by Eqn. 25.77. A0] ..(25.77) A thermistor exhibits a negative resistance temperature co-efficient which is typically about 0.05/°C. An individual thermistor curve can be closely approximated through the Steinhart-Hart equation: =A+ Blog, R+ C(log, R)° ...(25.78) where T= temperature; °K R= resistance of thermistor ; 2, A, B, C = curve fitting constants. A, and C are found by selecting three data points on the published data curve and solving the three simultaneous equations. When the data points are chosen to span no more than 100°C within the nominal centre of thermistorstemperature range, this equation approaches aremarkable +0.2 °Ccurve fit. Asimpler equation is : T= B log, R- A ..(25.79) where A, B andCare found by selecting three (R, T) data points and solving three resultant simultaneous equations. Equation 25.79 must be applied over a 25.20.4 Applications of Thermistors Although major applications of thermistors are measurement and controlof temperature, they may be used fora number of other applications. The various applications of themistors are : 1. Measurement of Temperature. A thermistor produces a large change of resistance with a small change in the temperature being measured. This large sensitivity of thermistor provides good accuracy and resolution. A typical industrial-type thermistor with a 2000S2 resistance at 25°C and a resistance temperature co-efficient of 3.9 percent per °Cexhibits a change of 78S2 per degree °C change is temperature. When this thermistor is connected in a simple series circuit consisting of a battery and micro-ammeter as shown in Fig. 25.69, any change in temperature causes a change in the resistance of thermistor and corres ponding change in the circuit current. The micro ammeter may be directly calibrated in terms of temperature. The micro-ammeter may be able to give a resolution of 0.1°C. Thermistor Battery E Micro-ammeter calibrated in terms of temperature Fig. 25.69 Simple series circuit for measurement of temperature using a thermistor. The use of a bridge circuit as shown in Fig. 25.70 gives higher sensitivities. The 4 k2 thermistor used will readily indicate as small changes as 0.005°C in temperature. The high sensitivity together with high thermistor resistance which may about 100 k2, makes the thermistor ideal for remote measurement or control, as the changes in contact or transmission line resistances due to change in the ambient temperature have almost a negligible effect on the accuracy of measurement or control. For example a 150 m long transmission line made of copper when subjected to change of 25°C will affect the accuracy of measurement or control by approximately 0.05°C. 792 Electrical and Electronic Measurements and 6. way the resistance of leads does not affect the readings and hence errors on this count () measurement of power at high frequencies (i) measurement of thermal conductivity liquids (iv) measurement of composition of gases 25.20.5 Salient Features of Thermistors Compact, over conventional thermocouples, resistance thermo meters, and filled system thermometer sensing elements for measurement of temperature. Thermistors not only used in other applications as explained in 25.20.4. (v) providing time delay. are are negligible. The above features give thermistorS advantages find use in temperature measurements but are also (v) vacuum measurements and 1. Thermistors rugged and inexpensive. resistance Example 25.26 A thermistor has temperature co-efficient of-5% over a temperature range of 25°C to 50°C. If the resistance of the thermistor is 100 2 at 25°C, what is the resistance at 35°C? 2. Thermistors when properly aged, have good stability. 3. The response time of thermistors can vary from a fraction of a second to minutes, depending on the size of the detecting mass and thermal capacity of the thermistor. It varies inversely with the dissipation factor. The power dissipation factor varies with the degree of thermal isolatiorn of the thermistor element. Solution. Resistance at a temperature of 35°C is: Rag = 100[1 -0.05(35 -25)] = 50°2 Example 25.27 Athermistor has a resistance of 3980 2 at the ice point (0°C) and 794 S2 at 50°C. The resistance temperature relationship is given by R = aR exp (b/T). Calculate the constants a and b. Calculate the rangeof resistance to be measured in case the temperature varies from 40°C to 100°C. Solution. The resistance at ice point R, = 3980 2 4. The upper operating limit of temperature for thermistors is dependent on physical changes in the material or solder used in attaching the electrical connections and is usually 400°C or less. The lower temperature limit of temperature is normally determined by the resistance reaching such a high value that it cannot be measured by standard methods. 5. The measuring Thermistors can be installed at a distance from their associated measuring circuits if elements of high resistance are used such that the resistance of leads (even though the leads may be very long) is negligible. This 4. Other Applications. The other applications of thermistors include: (iii) measurement of level, flow and pressure of Instrumentation current should be maintained to as low a value as possible so that self heating of thermistors is avoided Absolute temperature at ice point =273-K 3980 = ax 3980 x exp(b/273) or 1=aexp(b/273) ..() Resistance at 50°C is R, =794 2. Absolute temperature corresponding to 50°C T=273+50°=323 K° Hence, 794 = ax 3980 exp (b/323) =3980 exp (b/323) Solving () and (ii), we have, a =30x 10° and b= 2843 otherwise errors are introduced on account Absolute temperature at 40°C of change of resistance caused by self heating. Where it is not possible to avoid self heating, thermistor stability can be = 273+ 40 =313 Ko. .. Resistance at 40°C maintained at given temperature by using an auxiliary heating element. The average = 30 ×10°x3980x exp(2843/313) Absolute temperature at l100°C power dissipation can be effectively reduced = 273 +100 =373 °K and the highest sensitivity retained by energizing the thermistor with pulses of measuring power. ..(i) .:. Resistance at 100°C = 30 ×10°x3980 x exp(2843/373) Thus the range of resistance is 244 2 to 1051 2. 29.31 THERMOCoUPLES The thermocouple is one of the simplest and most commonly used methods of measuring process temperatures. The operation of a thermocouple Measurement of Non-Electric Quantities based upon Seebeck effect. 1099 In 1821, Seebeck discovered that when heat is applied tojunction (hot junction)of two dissimilar metals, an emf is generated which can be measured at the other junction (cold junction). The two dissimilar metals form an electric 3. In a circuit consisting of two dissimilar homogerneous metals having the junctions at different temperatures, the emf developed will not be affected when a third homogeneous metal is made a part of the circuit, provided the temperatures of its two junctions ircuit, and a current flows as a result of the generated are the same as shown in Fig. 29.67. rms is called Law emf as shown in Fig, 29.65. This current will continue to flow as long as I, > I,. Metal B is described as - ve of Intermediate Metals. with respect to a metal A if current flows into it at the cold junction. A+ I Hot Emf = E Metal A(+) Hot Metal B(-) Temp T, T,> T, T T, Current i B T,>T, Emf= E junction Cold junction junction Cold junction Temp T; Fig. 29.67 Introduction of a third metal does not affect the emf provided its two junctions are at the same temperature. In practice, some means of measuring enmf Fig. 29.65 Basic circuit of thermocouple. The emf produced is function of the difference in produced by athermocouple have to be used. This usually requires the introduction of a third metal into temperature of hot and cold junctions and is given by: the net emf in the circuit remains unaltered if a third E= aA0 where ...(29.64) (See Art. 25.21, page 793) A0 =difference between temperatures of hot and cold junctions. the circuit. The law of intermediate metals states that metal is of the third metal are at the same temperature. The third metal may be introduced anywhere in series with the circuit without affecting the net emf provided junctions J; and J4 are kept at the same temperature. The applications of this law are : 29.31.1 Thermo-electric Laws (i) The law makes it possible to use extension Several thermo-electric phenomena have been discovered which are called thermo-electric laws. wires of a metal different from the metals used for thermocouple. For example, the extension wires used for Platinum/Platinum These are : 1. The application of heat to a single homo geneous metal is in itself not capable of producing or sustaining an electric current. 2. A thermo-electric emf is produced when the junctions of two dissimilar homogeneous metals are kept at different temperatures. This emf is not affected by temperature gradients along the conductors shown in Fig. 29.66. A+ Cold Hot junction junction rhodium thermocouple may be made of copper which is an inexpensive material. (ii) The law enables a measuring instrument to be introduced into the circuit without affecting the emf generated by the thermocouple. (This is subject to the condition that the meter has an infinite impedance and therefore there are no loading effects.) (ii) Another important consequence of this law is that the wires forming the junction can be soldered or brazed together without altering the performance of the junction. (iv) The thermal emf of any two homogeneous metals with respect toanother is the algebraic T sum of their individual emfs with respect to a B T T,>T, Fig. 29.66 No emf is generated by temperature gradients in homogeneous conductors. third homogeneous metal. Figure 29.68 shows that emf of metal A with respect to B is E,AB and that of B with respect to Cis Egc and therefore the emf of A with respect to C is EAC = EAB + Egc: 29 Electrical and Electronic 1100 and J, is E. Suppose the emf between junctions Ez, the resultant and that between junctions lh and J3 is = E, = E. emf between junctions ) and J3 is Eg |A+ Emf EAB T, B B+ T Measurements nd Instrumentotinn Emf= EgC T This law is used while making corrections to the (cold) thermocouple readings in case reference which junction temperature is different from one for the thermocouple was calibrated. The calibration junction curves and charts are available for a reference temperature of 0°C. In case the temperature of reference junction is different from 0°C, the calibration curves no longer hold good and corrections have to be applied. Thus if a thermocouple calibrated with a A+ reference temperature 0°C is used with this junction at 20°C, the thermocouple will read correctly if the so Emf =EAc= EAB +EBC called lost emf due to reference junction being at 20°C is added to the measured value. The values of the lost emf can be read off from table of correction for T>T, thermocouple used. Fig. 29.68 Thermal emfs of two metals with respect to 5. The algebraic sum of the emfs produced in a one another is the algebraic sum of their individual emfs with respect to a third metal. circuit containing two or more thermocouples all at 4. The thermal emf produced when a circuit of 6. The net emf of a circuit containing two two homogeneous metals exists between a first the satire temperature is zero. thermocouples is unaffected by the addition of more temperature and a second and thermal emf produced thermocouples at the same temperature as any of the when the samne circuit exists between the second others as shown in Fig. 29.70. temperature and a third are algebraically equal to the thermal emf produced when the circuit exists between first and third temperatures. This is called Law of Intermediate Temperatures. Figure 29.69 illustrates this law. The emf Junction generated with junction temperatures T and T, is equal to the sum of emfs produced by two similar thermocouples, One operating with where T, lies between T, and T¡. Junction J2 IA+ -IA+ Junction T, B-1- T3 -B-! A+ T, !A T, junction temperature TË and T, and the other with T, and Ta Junction Junction Emf E, = E, +Ez T. B Fig. 29.69 The algebraic sum of thermal emfs pro duced between junctions J, and J, and between J, and J, is equal to emf E, produced in a similar circuit between junctions J, and J: T,>T, Fig. 29.70 Additional at junctions thermocouples J, and J, not affect the net emf. 29.15 MEASUREMENT OF PRESSURE P'ressure measurements are one of the most important measurements made in industry. The number of instruments used are by far greater in number than the instruments used for any other type of measurement. The principles used in the measurement of pressure are also, applied in the measurement of temperature, flow, and liquid levels. Thus it is essential to have complete knowledge of working principles of these instruments. Pressure is represented as force per unit area. As such it may be considered as a type of stress since stress is also defined as force per unit area. In this section, the term 'pressure' refers to the force per unit area exerted by a fluid on a containing wall. Therefore, the discussion of pressure measurement is limited to fluid systems. The forces that arise as a result of strains in solids are designated as stresses and have been discussed earlier. 29.16 TYPES OF PRESSURE MEASUREMENT DEVICES In industrial applications the pressure is usually measured by means of indicating gauges or recorders. These instruments may be mechanical, electro mechanical, electrical or electronic in operation. (i) Mechanical Instruments. These instruments may be classified into two groups. The first group includes those instruments in which the pressure 29 1072 Electrical and Electronic Measurements and Instrumentation transducers measurement is made by balancing an unknown force diagphrams see pages 742-749. Pressure include manometers and ring and belt type of gauges. summing members. While mass cantilever suspension and pivot torque types are found in accelerometers and velocity transducers. Secondary transducers. The displacement created by the action of the force summing member is converted into a change of some electrical parameter. The force summing member actuates a transducer which converts the displacement into an output of with a known force. Instruments using this principle The second group includes those instruments which employ the balancing of unknown force through a force produced on or known area due to stress in an elastic member. This group employs quantitative deformation of an elastic member for measurement of pressure. The elastic members used are Bourdor tubes, bellows and diaphragms. (i) Electro-Mechanical Instruments. These instruments usually employ a mechanical means for detecting the pressure and electrical means for indicating or recording the detected pressure. (ü) Electronic Instruments. Electronic pressure measuring instruments normally depend on some generally use one of the first four types of torce electrical format. The various transducers used are of the following types : Resistive, Inductive, A Differential transformers, physical change that can be detected and indicated or A Capacitive, recorded electronically. A Photo-electric, In this text, the discussion is limited only to Electro-mechanical and Electronic instruments. 29.17 MEASUREMENT OF PRESSURE USING ELECTRICAL TRANSDUCERS AS SECONDARY TRANSDUCERS The measurement of force or pressure can be done by converting the applied force or pressure into a displacement by elasticelements which act as primary transducers. This displacemnent, which is a function of pressure may be measured by transducers which act as secondary transducers. The output of the secondary transducers is a function of displacement, which in turn is a function of pressure. Mechanical methods have to be used to convert the applied force or pressure into displacement. These devices are called Force Summing Devices. They possess elasticity, when deformed, the stresses established in the summing devices establish equilibrium with the applied pressure. The choice and design of the type of summing element used depends on the magnitude of force or pressure to be measured. The most commonly used summing devices are : Flat or corrugated diaphragms. A Bellows. Circular or twisted Bourdon fube. Straight tube. Single or double mass cantilever suspension. A Pivot torque. Examples of these force summing devices are shown in Fig. 25.4 on page 742. For description of force summing devices like Bourdon tube, bellows and A Piezo-electric, Ionization, and A Oscillation. Measurement of Non-Electric Quantities 1075 The output of Oscillator is a modulated output and can be demodulated and calibrated in terms of pressure or force applied. Advantages : (i) This transducer measures both dynamicand static phenomena. (i) This transducer is very useful for telemetry applications. Disadvantages : (i) This transducer has temperature range. very hunted (i)It has poor thermal stability. (iii) It has a low accuracy and therefore is used only in low accuracy applications. 7. Oscillation Transducers These transducers use a force summing member to change the capacitance, C, or inductance, L, of an LC Oscillator circuit. Figure 29.29 shows the basic elements of LC transistor oscillator whose output frequency is affected by a change in the inductance of a coil. The change in inductance is caused by the force summing member acting upon an inductive device. Mechanical C(variable) L(ixed) FM Oscillator output linkage Diaphragm (Force summing device) Fig. 29.29 Basic elements of an oscillation transducer. 25.24 LINEAR VARIABLE DIFFERENTIAL TRANSFORMER (LVDT) The most widely used inductive transducer to translate the linear motion £nto electrical signals is the linear variable differential transformer (LVDT). The basic 29 29.42 MEASUREMENT OF FLOW There are a number of devices for sensing the rate of fluid flow. They mainly operate on the principle ot placing an obstruction in the path of fluid causing a change in fluid pressure which is dependent upon the rate of flow. Thus by measuring the difference in pressure before and after the obstruction by means of a differential pressure sensor, the rate of flow may be determined. They are, in fact, mechanical means of measuring rate of liquid flow. The examples of these flow meters are :Orifice plate, venturi tube and Rota meter. Some of these methods have been explained in Chapter 25. These are indirect means of meàsuring fluid flow. However, there are some direct methods of measuring fluid flow which are described below. These methods employ electrical means directly. 29.42.1 Turbine Meters There have been extremely rapid developments in turbine meters in recent years, partly because of the 1110 Electrical and Electronic Measurements and Instrumentation advances in electronics technology and the case with Limitations which the output may beused to indicate rate of flow () Errors may be caused by excessive frictional or be integrated to give total flow. An exploded view torques. Also errors arise on account of wear of the meter is shown in Fig. 29.83. and corrosion of bearings. This calls for Turbine flow meters are volumetric flow meters and are available in wide ranges. The output is usually specialdesign of bearings. (ii) The turbine is subject to variations in performance caused by the characteristics of the liquid, friction or bearings, etc. When the in the form of a digital electrical signal whose trequency is directly proportional to flow rate and whose total count is proportional to the total quantity, flow rates approach zero, the slippage may as each pulse represents a discrete volume. Magnetic sensing Flow pick-up straighteners amount to 100%, i.e., the turbine stalls and registers zero output. Therefore, at low flow rates, there is a possibility of large errors. 29.42.2 Electromagnetic Flow Meters Electromagnetic flow meters are particularly suitable for the flow measurements of slurries, sludge and any electrically conducting liquid. A schematic diagram of an electromagnetic flowmeter is shown in Fig. 29.84. It consists basically Impeller of a pair of insulated electrodes buried flush in the opposite sides of a non-conducting, non-magnetic pipecarrying the liquid whose flow is to be measured. Fig. 29.83 Turbine flowmeter. Core Figure 29.83 shows a magnetic pickup type of turbine flow meter. A feature of this turbine meter is a hydraulically supported turbine rotor. A permanent magnet sealed inside the rotor body is polarized at 90° Non-metallic portion of pipe Steady d.c. supply to the axis of the rotation. As the rotor rotates so does the magnet and therefore rotating magnetic field is produced. This produces an a.c. voltage pulse in the pick-up coil located external to the meter housing. The frequency of this voltage is directly proportional to the rate of flow. The pulse carn be totalized by a counter to give the value of total flow over a particular interval of time. Coil -Electrode Fluid flow Pipe Advantages : Fig. 29.84 Electromagnetic flow meter. () The output is in electrical digital form which lends itself admirably to line or radio telemetry for recording or control ata distant point. (ii) Passage of rotor past the pick up coil The pipe is surrounded by an electromagnet which produces a magnetic field. The arrangement is analogous to a conductor moving across a magnetic field. Therefore, voltage is induced the electrodes. This voltage is given by : across produces an emf which can be converted to a d.c. analog voltage by a D/A converter for indication on a conventional d.c. instrument or recorded on a potentiometric recorder. (iif) The pulse output may be summed on a simple counter giving totalized flow without loss of accuracy. The error is +0.5%. approximately E= Blv volt where B= flux x density ; Wb/m', l= length of conductor = diameter of pipe ; m, and V= velocity of conductor (flow) ; m/s Thus, assuming a constant magnetic field, the magnitude of the voltage appearing across the electrodes will be directly proportional to velocity. Measurement of Non-Electric Quantities 1111 Non-conducting pipe has to be used as the output voltage gets short circuited if metallic pipes are used. This is true when liquids of low conductivity are being measured. But when liquids of high conductivity are measured the short circuiting has no effect. Stainless steel pipes can then be used. The voltages produced are small specially at low flow rates. Therefore, the meter relies greatly on a high gain amplifier to convert the induced voltage into a usable form. Advantages : () The electromagrnetic flow meters may be manufactured to measure flow in pipes of any size provided powerful magnetic field can be produced. (i)The major advantage from a fluid handling point of view is that with the electro-magnetic flow meter there is no obstruction to flow that may cause pressure drops. (ii) The output (voltage) is linearly rated to the input (flow rate). (iv) The output is unaffected by changes is characteristics of liquid such as viscosity, pressure, and temperature. Limitations : () The operating costs are high particularly if heavy slurries are handled. (i) The conductivity of the liquid being metered should not be less than 10 4 2/m. As general rule it will be found that most aqueous solutions are adequately conductive while majority of hydrocarbon solutions are not sufficiently conductive.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )