Experiment 1
Purification of an Impure Acetanilide Sample by Recrystallization and
Determination of Purity by Melting Point
Objectives
• To illustrate the concept of recrystallization and its application
• To demonstrate the proper techniques in recrystallizing an impure organic compound
• To illustrate the principles and proper techniques in the determination of melting point, one of the physical properties
of organic compounds
Reagents
Acetanilide (N-Phenylacetamide, C8H9NO), Impure Acetanilide (Acetanilide-sodium chloride-congo red mixture),
activated carbon, acetone (2-propanone, C3H6O), Ethyl alcohol (ethanol, C2H6O), and toluene (Methylbenzene, C7H8).
Materials
A. For Recrystallization
Test tubes, beaker, graduated cylinders, medicine dropper, hot plate, Bunsen burner wire gauze, iron ring, iron stand,
test tube holder, stirring rod, short stem funnel, steam bath, Büchner funnel with stopper, vacuum flask, crucible tongs
and an ice water bath
B. For Melting Point Determination
Mel-Temp apparatus, glass plates, spatula
Procedure
A. Determination of an Appropriate Solvent for Recrystallizing Acetanilide
Perform the succeeding procedure in testing the solubility of acetanilide in water [H2O], ethanol [CH3CH2OH], acetone
[(CH3)2CO] and toluene [C6H5CH3]. Determine which solvent is most suitable for recrystallizing acetanilide
[C6H5NHCOCH3].
Place approximately 25 mg of acetanilide into a test tube containing 1 mL of solvent being tested. Shake the tube and
observe. If the substance fails to dissolve, heat the test tube gently under a hot water bath. Do not heat longer than
necessary to avoid undue evaporation of the solvent. If undissolved solid still remains, add 1 mL more solvent and
warm. Shake the test tube and observe for the dissolution of acetanilide. Test for the solubility of acetanilide in water,
CH3CH2OH, (CH3)2CO and C6H5CH3.
Cool the contents of four test tubes (i.e. H2O, CH3CH2OH, (CH3)2CO and C6H5CH3) and observe for any reappearance
of the crystals. If crystals do not appear in any of the test tubes, add a pin head-size acetanilide crystal into the solution
or scratch the inside wall of the test tube beneath the solvent surface. Which solvent do you observe will be most
suitable for recrystallizing acetanilide? Why? Report your findings to the instructor.
B. Recrystallization of Impure Acetanilide
Accurately weigh 1 g of impure acetanilide. Place it in an Erlenmeyer flask and add 50 mL of the solvent that was
observed to be suitable for recrystallizing the compound. Heat the mixture, stirring it uniformly until it almost boils. If
the solution is colored, add a pinch of activated charcoal and continue heating to almost boiling. Check if the suspension
is still colored by spotting a drop of the mixture on filter paper. Add more activated charcoal if necessary. Meanwhile,
prepare to filter the hot suspension.
Prepare a filtration set-up (Figure 1) by folding a fluted filter paper and placing it on a funnel. Use a 125-mL Erlenmeyer
flask as the receiver. Pre-heat the set-up just prior to use by pouring hot solvent into the filter paper. Why? Empty the
flask and filter the hot suspension. It is essential that this operation be completed as quickly as possible in order that
cooling is minimized. Why? It is also advisable to place only a few mL of the hot solution into the funnel, keeping the
remainder of the solution in the flask hot by heating over the Bunsen flame until it is transferred to the funnel.
Figure 1: Filtration Set-up using a Fluted filter paper.
If the filtrate remains to be colored, add a pinch of activated charcoal and heat. Refilter by gravity filtration.
Allow it to cool slowly to room temperature undisturbed. Observe the appearance of crystals. To induce crystallization
of more acetanilide, chill the flask in an ice-water bath and scratch the walls of the flask in contact with the solution.
While waiting for most of the acetanilide to recrystallize, assemble the suction filtration apparatus (Figure 2) as follows:
cut a circular piece of filter paper of such diameter that it exactly covers the flat surface of the perforated portion of the
Büchner funnel filter plate. Determine the weight of this paper and place it in the Büchner funnel. Fit the Büchner funnel
to a suction flask.
Figure 2: Suction Filtration Apparatus.
When the suction filtration apparatus has been set-up, moisten the paper in the funnel with a few drops of the solvent,
(why?) and draw the solvent down through the suction. Now, filter the crystals out of the solution by pouring it in the
Büchner funnel and the solvent will eventually be drawn inside the vacuum flask through suction. When the crystals
are almost dry, release the vacuum by disconnecting the tube from the suction flask (Do not turn the pump off!) and
wash the crystals with 5-10 mL cold solvent with stirring (use a stirring rod) for half a minute. Reconnect the tube to dry
the crystals.
To dry the crystals, transfer the crystals together with the filter paper into a watch glass, cover it with another filter
paper and keep it in the locker until the next laboratory period and experiment (melting point determination). Weigh the
dried crystals and filter paper to the nearest 0.01 gram. Determine the percentage of the pure crystals recovered from
the impure sample.
C. Melting point determination
Determine the melting point of the recrystallized and impure acetanilide from the previous experiment. Using the melting
point apparatus, adjust the temperature setting from 10-20°C. Do not set the temperature greater than this range.
(Why?) Place very few amounts of the acetanilide sample on the glass plate and place this on the heating plate of the
apparatus. Observe the crystals and record the temperature range at which the crystals start to melt until all of it has
melted. Remove the glass plate from the apparatus and clean it for the next person to use.
NOTE: Do not discard the glass plate. Properly dispose of its contents and return it to the technician.
Guide Questions:
1. Among the following solvents – water, acetone, ethanol, and toluene, which one was observed to be most suitable for
recrystallization of acetanilide? Why?
2. Why was a water bath used instead of direct heating in the choice of solvent?
3. Why was activated charcoal added into the mixture of acetanilide, sodium chloride and congo red? What is adsorption?
4. Would it be wrong to dissolve the original impure material in a large excess of solvent? Why?
5. In gravity filtration, what is the advantage of using a short-stemmed funnel over a long-stem funnel?
6. Why were the funnel and the flask preheated before filtering the impure acetanilide?
7. Why was the filter paper in the Büchner funnel moistened before pouring in the mixture containing the acetanilide to
be recrystallized?
8. What is the purpose of washing the acetanilide crystals with a few mL of cold solvent? What do you think would happen
if the washing solvent was not cold?
9. Why must the rubber tubing of the suction flask be disconnected before turning off the water aspirator?
10. Why is it necessary to use thick-walled tubing in connecting the suction flask to the aspirator?
11. At what steps in the recrystallization procedure did you lose some of the product? What can you do in the future to
avoid this losses?
12. What is the effect of impurities on the observed melting point of acetanilide?
13. Given the solubilities of the following compounds:
Water
Ethanol
Cold
Hot
Cold
Hot
Acetamide
s
s
s
s
Aspirin
i
s
s
s
Sample Y
i
s
s
s
where s means soluble; i means insoluble; and ss means slightly soluble
Benzene
Cold
ss
ss
i
Hot
s
ss
ss
(A) Which of the solvents would be suitable for recrystallization of acetamide? Of aspirin?
(B) Could acetamide be separated from acetanilide by recrystallization from water? Why or why not?
(C) Could aspirin be separated from acetanilide by recrystallization from water? Why or why not?
(D) Devise a recrystallization scheme for the purification of aspirin contaminated with small amount of acetamide and
sample Y.