Installation Program Installer/tech – Course Review Professionalism © BICSI 2018 _____________ is obtained by repeat positive actions on a daily basis A. Professionalism B. Customer service C. Ethos D. Credentials 2 _____________ is obtained by repeat positive actions on a daily basis A. Professionalism B. Customer service C. Ethos D. Credentials 3 The installer must take responsibility to know, understand, and _______ all aspects of a job. A. apply B. estimate C. respect D. communicate 4 The installer must take responsibility to know, understand, and _______ all aspects of a job. A. apply B. estimate C. respect D. communicate 5 Cable installation companies are dependent on ________ for new and repeat business. A. manufacturers B. distributors C. customers D. colleagues 6 Cable installation companies are dependent on ________ for new and repeat business. A. manufacturers B. distributors C. customers D. colleagues 7 Listening carefully, respecting values, & seeking the understanding of others is all apart of: A. Advanced troubleshooting B. Effective communication C. Best practices D. Standards compliance 8 Listening carefully, respecting values, & seeking the understanding of others is all apart of: A. Advanced troubleshooting B. Effective communication C. Best practices D. Standards compliance 9 Principles of Transmission © BICSI 2018 __________ is the movement of electrical energy in the form of electrical signals from point to point. A. Apparent power B. Performance C. Interference D. Transmission 11 __________ is the movement of electrical energy in the form of electrical signals from point to point. A. Apparent power B. Performance C. Interference D. Transmission 12 The number of cycles a signal is repeated in a given time is known as: A. Full Duplex B. Frequency C. Modulization D. Mbps 13 The number of cycles a signal is repeated in a given time is known as: A. Full Duplex B. Frequency C. Modulization D. Mbps 14 If 60 cycles in 1s is 60 Hz, then 1,000,000 cycles in 1s is: A. 1 Kilohertz (KHz) B. 1 Megahertz (MHz) C. 1 Gigahertz (GHz) D. 1 Terahertz (THz) 15 If 60 cycles in 1s is 60 Hz, then 1,000,000 cycles in 1s is: A. 1 Kilohertz (KHz) B. 1 Megahertz (MHz) C. 1 Gigahertz (GHz) D. 1 Terahertz (THz) 16 The formula for calculating true power is: A. A = πr² B. E=MC² C. V=IR D. P=VI 17 The formula for calculating true power is: A. A = πr² B. E=MC² C. V=IR D. P=VI 18 The basic unit of measurement for capacitance is a _________. A. Henry B. Farad C. Ampere D. Ohm 19 The basic unit of measurement for capacitance is a _________. A. Henry B. Farad C. Ampere D. Ohm 20 A gauge change of three numbers approximately ______ or ______ a conductors cross sectional area. A. doubles or triples B. decreases or weakens C. increases or strengthens D. doubles or halves 21 A gauge change of three numbers approximately ______ or ______ a conductors cross sectional area. A. doubles or triples B. decreases or weakens C. increases or strengthens D. doubles or halves 22 Copper Cabling Media © BICSI 2018 The property of a conductor that opposes any change in current flow because of an electromagnetic field is _________. A. Resistance B. Impedance C. Inductance D. Capacitance 24 The property of a conductor that opposes any change in current flow because of an electromagnetic field is _________. A. Resistance B. Impedance C. Inductance D. Capacitance 25 The 100 Ohm characteristic impedance of a UTP cable will remain the same if the length is double or tripled at 100 Mhz. A. True B. False 26 The 100 Ohm characteristic impedance of a UTP cable will remain the same if the length is double or tripled at 100 Mhz. A. True B. False 27 The ratio of power of the outgoing signal to the power of the reflected signal (expressed in decibels) is called ___________. A. NVP B. Insertion Loss C. Return Loss D. Attenuation 28 The ratio of power of the outgoing signal to the power of the reflected signal (expressed in decibels) is called ___________. A. NVP B. Insertion Loss C. Return Loss D. Attenuation 29 Untwisting of pairs in a UTP cable can affect inductance between conductors. A. True B. False 30 Untwisting of pairs in a UTP cable can affect inductance between conductors. A. True B. False 31 What color is the 15th pair of a twenty-five pair cable? A. White-orange B. Black-slate C. Yellow-brown D. Red-green 32 What color is the 15th pair of a twenty-five pair cable? A. White-orange B. Black-slate C. Yellow-brown D. Red-green 33 The unwanted transfer of a signal’s electromagnetic energy from one or more circuits is called _______. A. Crosstalk B. Propagation Delay C. Attenuation D. Feedback 34 The unwanted transfer of a signal’s electromagnetic energy from one or more circuits is called _______. A. Crosstalk B. Propagation Delay C. Attenuation D. Feedback 35 8P8C stands for: A. 8 Position 8 Conductor B. 8 Pin 8 Contact C. 8 Position 8 Contact D. 8 Pin 8 Conductor 36 8P8C stands for: A. 8 Position 8 Conductor B. 8 Pin 8 Contact C. 8 Position 8 Contact D. 8 Pin 8 Conductor 37 75 Ohm Series 6 coaxial cable is primarily used for backbone cabling. A. True B. False 38 75 Ohm Series 6 coaxial cable is primarily used for backbone cabling. A. True B. False 39 Optical Fiber Cabling Media © BICSI 2018 The cladding size of OS 1 (single-mode ISP) optical fiber is _______. A. 9 µm B. 62.5 µm C. 125 µm D. 250 µm 41 The cladding size of OS 1 (single-mode ISP) optical fiber is _______. A. 9 µm B. 62.5 µm C. 125 µm D. 250 µm 42 The cladding size of OM 1 (multi-mode) optical fiber is _______. A. 9 µm B. 62.5 µm C. 125 µm D. 250 µm 43 The cladding size of OM 1 (multi-mode) optical fiber is _______. A. 9 µm B. 62.5 µm C. 125 µm D. 250 µm 44 Which type of optical fiber is used for OSP installations and allows the cable jacket to expand or contract with temperature fluctuations? A. Loose-tube B. Tight-buffer C. Buffer-tube Fan-out D. Righty-tighty Lefty-loosey 45 Which type of optical fiber is used for OSP installations and allows the cable jacket to expand or contract with temperature fluctuations? A. Loose-tube B. Tight-buffer C. Buffer-tube Fan-out D. Righty-tighty Lefty-loosey 46 The most common diameter of tight-buffer optical fiber strand is _____. A. 250 µm B. 850 µm C. 900 µm D. 1300 µm 47 The most common diameter of tight-buffer optical fiber strand is _____. A. 250 µm B. 850 µm C. 900 µm D. 1300 µm 48 Which sheath listing describes an optical fiber cable that is shielded and usable in a plenum airspace? A. OFCP B. OFNR C. OFCR D. OFNP 49 Which sheath listing describes an optical fiber cable that is shielded and usable in a plenum airspace? A. OFCP B. OFNR C. OFCR D. OFNP 50 What type of single-mode fiber has a sheath color of red? A. Outside plant B. Dispersion shifted C. Inside plant D. Polarization maintaining 51 What type of single-mode fiber has a sheath color of red? A. Outside plant - Black B. Dispersion shifted C. Inside plant - Yellow D. Polarization maintaining - Blue 52 What type of dispersion results in different lengths of light paths as they propagate from the source to the receiver? A. Chromatic B. Monochromatic C. Distortion D. Modal 53 What type of dispersion results in different lengths of light paths as they propagate from the source to the receiver? A. Chromatic B. Monochromatic C. Distortion D. Modal 54 The IOR (Index of Refraction) is greater in the core than in the cladding. This allows the signal to “reflect” and propagate through the fiber. A. True B. False 55 The IOR (Index of Refraction) is greater in the core than in the cladding. This allows the signal to “reflect” and propagate through the fiber. A. True B. False 56 The bend radius for intrabuilding optical fiber during installation is ___________________. A. 50 mm (2 in) B. 15 times the outside diameter C. 20 times the outside diameter D. 25 times the outside diameter 57 The bend radius for intrabuilding optical fiber during installation is ___________________. A. 50 mm (2 in) – optical fiber (up to 4 strands) B. 10 times the outside diameter C. 20 times the outside diameter D. 25 times the outside diameter 58 Some optical fibers use a third layer of glass, known as the trench or moat, which surrounds the core. This fiber is known as: A. Bend insensitive B. Dispersion shifted C. Laser optimized D. Low smoke zero halogen 59 Some optical fibers use a third layer of glass, known as the trench or moat, which surrounds the core. This fiber is known as: A. Bend insensitive B. Dispersion shifted C. Laser optimized D. Low smoke zero halogen 60 An LC connector is classified as a ________. A. Subscriber connector (SC) B. Straight-tip connector (ST) C. Multifiber Push-on (MPO) D. Small-form Factor (SFF) 61 An LC connector is classified as a ________. A. Subscriber connector (SC) B. Straight-tip connector (ST) C. Multifiber Push-on (MPO) D. Small-form Factor (SFF) 62 Codes, Standards, & Regulations © BICSI 2018 Once a code is adopted or ratified by a government or other formally authorized body, it can be legally enforced by an: A. Fire marshal B. Building inspector C. Electrical inspector D. All of the above 64 Once a code is adopted or ratified by a government or other formally authorized body, it can be legally enforced by an: A. Fire marshal B. Building inspector C. Electrical inspector D. All of the above 65 Designers and installers must have a thorough knowledge of the applicable sections of _______ that legally affect telecommunications. A. codes B. recommendations C. electromagnetic interference D. parameters 66 Designers and installers must have a thorough knowledge of the applicable sections of _______ that legally affect telecommunications. A. codes B. recommendations C. electromagnetic interference D. parameters 67 As with most standards, telecommunications, ICT, and ESS standards are typically ________ adopted A. voluntarily B. unanimously C. globally D. seasonally 68 As with most standards, telecommunications, ICT, and ESS standards are typically ________ adopted A. voluntarily B. unanimously C. globally D. seasonally 69 Structured Cabling Systems © BICSI 2018 The two types of backbone cables are referred to as _______ and _________. A. single-mode and multi-mode B. interbuilding and intrabuilding C. vertical and horizontal D. loose-tube and tight-buffered 71 The two types of backbone cables are referred to as _______ and _________. A. single-mode and multi-mode B. interbuilding and intrabuilding C. vertical and horizontal D. loose-tube and tight-buffered 72 Sub system 3 backbones consist of cables installed between: A. MC (CD) and IC (BD) B. MC (CD) and HC (FD) C. MC (CD) and DEMARC D. All of the above 73 Sub system 3 backbones consist of cables installed between: A. MC (CD) and IC (BD) B. MC (CD) and HC (FD) C. MC (CD) and DEMARC D. All of the above 74 Sub system 2 backbones consist of cables installed between: A. MC (CD) and IC (BD) B. IC (BD) and HC (FD) C. IC (BD) and DEMARC D. B and C 75 Sub system 2 backbones consist of cables installed between: A. MC (CD) and IC (BD) B. IC (BD) and HC (FD) C. IC (BD) and DEMARC D. B and C 76 The maximum allowed horizontal (sub system 1) length of an optical fiber cable is ______. A. 90 m (295 ft) B. 160 m (525 ft) C. 200 m (656 ft) D. 260 m (850 ft) 77 The maximum allowed horizontal (sub system 1) length of an optical fiber cable is ______. A. 90 m (295 ft) B. 160 m (525 ft) C. 200 m (656 ft) D. 260 m (850 ft) 78 The horizontal cabling provided to each individual work area SHALL consist of: A. Two 4-pair 100 Ohm cables (Cat 5e minimum) B. Two strands of 50µm OM3 and one 4-Pair 100 Ohm cable (Cat 5e minimum) C. Two strands of OS1 single-mode and one 4-Pair 100 Ohm cable (Cat 5e minimum) D. All of the above 79 The horizontal cabling provided to each individual work area SHALL consist of: A. Two 4-pair 100 Ohm cables (Cat 5e minimum) B. Two strands of 50µm OM3 and one 4-Pair 100 Ohm cable (Cat 5e minimum) C. Two strands of OS1 single-mode and one 4-Pair 100 Ohm cable (Cat 5e minimum) D. All of the above 80 The connection between a backbone cable and a horizontal cable is called a _________. A. interconnect B. cross-connect C. demarcation point D. cable connection point 81 The connection between a backbone cable and a horizontal cable is called a _________. A. interconnect B. cross-connect C. demarcation point D. cable connection point 82 Stranded conductors have 20% more attenuation for 24 AWG and 50% more for 26 AWG than solid conductors do for the same gauges. A. True B. False 83 Stranded conductors have 20% more attenuation for 24 AWG and 50% more for 26 AWG than solid conductors do for the same gauges. A. True B. False 84 For cross-connect fields, the color code for a Network connection is _______. A. Orange B. Green C. Blue D. Purple 85 For cross-connect fields, the color code for a Network connection is _______. A. Orange B. Green C. Blue D. Purple 86 During a project, documenting the details related to the infrastructure and equipment in a logical way is known as: A. organizing B. recordkeeping C. estimating D. proposing 87 During a project, documenting the details related to the infrastructure and equipment in a logical way is known as: A. organizing B. recordkeeping C. estimating D. proposing 88 What is an example of a basic system for recordkeeping? A. Memorization B. Milk crates C. Spreadsheets D. Map IT G2 89 What is an example of a basic system for recordkeeping? A. Memorization B. Milk crates C. Spreadsheets D. Map IT G2 90 By using a consolidation point (CP) you can extend the maximum length of a horizontal cable run greater than 90m (295 ft) A. True B. False 91 By using a consolidation point (CP) you can extend the maximum length of a horizontal cable run greater than 90m (295 ft) A. True B. False 92 In TR’s, jumpers and cords SHALL not exceed 5 m (16.5 ft) for 24 AWG and 4 m (13 ft) for 26 AWG. A. True B. False 93 In TR’s, jumpers and cords SHALL not exceed 5 m (16.5 ft) for 24 AWG and 4 m (13 ft) for 26 AWG. A. True B. False 94 There are ___ classes of administration of SCS. A. 2 B. 4 C. 6 D. 8 95 There are ___ classes of administration of SCS. A. 2 B. 4 C. 6 D. 8 96 A Class 2 SCS would be a________________. A. Single site with multiple buildings and Telecommunication spaces B. Single site with one telecommunication space C. Remote site with single telecommunication space D. Single site with multiple telecommunications spaces 97 A Class 2 SCS would be a________________. A. Single site with multiple buildings and Telecommunication spaces B. Single site with one telecommunication space C. Remote site with single telecommunication space D. Single site with multiple telecommunications spaces 98 The recommended topology for SCS backbone cabling is: A. Dual-Ring B. Star C. Hierarchical star D. Tree 99 The recommended topology for SCS backbone cabling is: A. Dual-Ring B. Star C. Hierarchical star D. Tree 100 Telecommunications Spaces © BICSI 2018 The primary purpose of a Entrance Facility (EF) is: A. To provide a demarcation point for SP’s B. House the transition of OSP cabling C. Both A & B D. None of the above 102 The primary purpose of a Entrance Facility (EF) is: A. To provide a demarcation point for SP’s B. House the transition of OSP cabling C. Both A & B D. None of the above 103 Which EF is most economical over the life cycle of a building? A. Underground B. Tunnel C. Direct Buried D. Aerial 104 Which EF is most economical over the life cycle of a building? A. Underground B. Tunnel C. Direct Buried D. Aerial 105 An Equipment Room (ER) ____________. A. serves an entire building, campus, or customer. B. is considered to be floor serving as opposed to building serving C. is limited to serving a limited space up to 3600 ft² D. shall not be used in place of a TR 106 An Equipment Room (ER) ____________. A. serves an entire building, campus, or customer. B. is considered to be floor serving as opposed to building serving C. is limited to serving a limited space up to 3600 ft² D. shall not be used in place of a TR 107 A Telecommunications Room (TR) ____________. A. serves an entire building, campus, or customer. B. is considered to be floor serving as opposed to building serving C. is limited to serving a limited space up to 3600 ft² D. shall not be used in place of a TR 108 A Telecommunications Room (TR) ____________. A. serves an entire building, campus, or customer. B. is considered to be floor serving as opposed to building serving C. is limited to serving a limited space up to 3600 ft² D. shall not be used in place of a TR 109 The size of a typical work area is 10m² (100 ft²) A. True B. False 110 The size of a typical work area is 10m² (100 ft²) A. True B. False 111 Space Preparation & Cabling Support Systems © BICSI 2018 2 Post racks are typically 7 ft high, and ____ or _____ inches wide. A. 18 or 24 B. 19 or 23 C. 20 or 26 D. 22 or 28 113 2 Post racks are typically 7 ft high, and ____ or _____ inches wide. A. 18 or 24 B. 19 or 23 C. 20 or 26 D. 22 or 28 114 Fall protection is required whenever a person is exposed to a fall hazard greater than __________. A. 1 m (3.3 ft) B. 2 m (6.6 ft) C. 3 m (9.8 ft) D. 4 m (13 ft) 115 Fall protection is required whenever a person is exposed to a fall hazard greater than __________. A. 1 m (3.3 ft) B. 2 m (6.6 ft) C. 3 m (9.8 ft) D. 4 m (13 ft) 116 What is the minimum clearance of isle space between and around equipment in telecommunication spaces? A. 1 m (3.3 ft) B. 2 m (6.6 ft) C. 3 m (9.8 ft) D. 4 m (13 ft) 117 What is the minimum clearance of isle space between and around equipment in telecommunication spaces? A. 1 m (3.3 ft) B. 2 m (6.6 ft) C. 3 m (9.8 ft) D. 4 m (13 ft) 118 How many walls in a TR are recommended to have plywood installed on them? A. 1 B. 2 C. 3 D. None 119 How many walls in a TR are recommended to have plywood installed on them? A. 1 B. 2 C. 3 D. None 120 What grade of plywood should be used in TRs? A. A/B B. B/C C. A/C D. C/D 121 What grade of plywood should be used in TRs? A. A/B B. B/C C. A/C D. C/D 122 BICSI does not recommend PVC conduit to be used inside buildings A. True B. False 123 BICSI does not recommend PVC conduit to be used inside buildings A. True B. False 124 Of the following, which conduit is made of the thickest gauge metal? A. EMT B. ENT C. RMC D. IMC 125 Of the following, which conduit is made of the thickest gauge metal? A. EMT B. ENT C. RMC D. IMC 126 The maximum fill ratio for installations of conduits is _____ percent. A. 30 B. 60 C. 52 D. 40 127 The maximum fill ratio for installations of conduits is _____ percent. A. 30 B. 60 C. 52 D. 40 128 Which conduit orientation terminates in a horizontal orientation? A. Stub out B. Stub up C. Stub top D. Stub down 129 Which conduit orientation terminates in a horizontal orientation? A. Stub out B. Stub up C. Stub top D. Stub down 130 Three common types of conduit bodies are: A. Elbow out, elbow in, elbow up B. Inside elbow, outside elbow, topside elbow C. Internal elbow, external elbow, median elbow D. Elbow right, elbow left, elbow back 131 Three common types of conduit bodies are: A. Elbow out, elbow in, elbow up B. Inside elbow, outside elbow, topside elbow C. Internal elbow, external elbow, median elbow D. Elbow right, elbow left, elbow back 132 To support continuous raceways, a trapeze support system can be made by using two _______ and a section of _________. A. guy-wires / conduit hanger B. drop wires / basket raceway C. all-thread rods / channel stock D. wall supports / guy-wire 133 To support continuous raceways, a trapeze support system can be made by using two _______ and a section of _________. A. guy-wires / conduit hanger B. drop wires / basket raceway C. all-thread rods / channel stock D. wall supports / guy-wire 134 The two forms of innerducts listed in the ITSIMM are: A. fabric and tube B. corrugated and insulated C. Continuous and non-continuous D. flexible and rigid 135 The two forms of innerducts listed in the ITSIMM are: A. fabric and tube B. corrugated and insulated C. Continuous and non-continuous D. flexible and rigid 136 A j-hook is an example of what kind of cable support? A. Open-top / non-continuous B. Open-top / continuous C. Open structure / continuous D. Metallic flexible hooks 137 A j-hook is an example of what kind of cable support? A. Open-top / non-continuous B. Open-top / continuous C. Open structure / continuous D. Metallic flexible hooks 138 Safety © BICSI 2018 First aid is the treatment that can be given before emergency medical services can be obtained. A. True B. False 140 First aid is the treatment that can be given before emergency medical services can be obtained. A. True B. False 141 Cardiopulmonary resuscitation (CPR) is the emergency procedure used on someone who is not breathing and whose suffered cardiac arrest. A. True B. False 142 Cardiopulmonary resuscitation (CPR) is the emergency procedure used on someone who is not breathing and whose suffered cardiac arrest. A. True B. False 143 First aid procedures for the exposure to hazardous substances can be found in: A. Request for proposal (RFP) B. Safety data sheets (SDS) C. Scope of Work (SOW) D. Bill of material (BOM) 144 First aid procedures for the exposure to hazardous substances can be found in: A. Request for proposal (RFP) B. Safety data sheets (SDS) C. Scope of Work (SOW) D. Bill of material (BOM) 145 The ABC’s of performing a primary survey of an injured person stand for: A. Arteries, bronchial, cardiac B. Arms, back, chest C. Alert, brace, check D. Airway, breathing, circulation 146 The ABC’s of performing a primary survey of an injured person stand for: A. Arteries, bronchial, cardiac B. Arms, back, chest C. Alert, brace, check D. Airway, breathing, circulation 147 The PPE that an installer is required to wear when performing a task depends on the: A. Hazards of the task B. Hazards at the work site C. Local, state, and national safety requirements D. All of the above 148 The PPE that an installer is required to wear when performing a task depends on the: A. Hazards of the task B. Hazards at the work site C. Local, state, and national safety requirements D. All of the above 149 In addition to offering impact protection, certain classes of hard hats can protect the head from electrical shock. A. True B. False 150 In addition to offering impact protection, certain classes of hard hats can protect the head from electrical shock. A. True B. False 151 Bonding & Grounding © BICSI 2018 The device of an AC Grounding Electrode system that establishes an electrical connection with earth is the ___________. A. AC Equipment Ground (ACEG) B. Telecommunications Bonding Conductor (TBC) C. Grounding Electrode Conductor (GEC) D. Grounding Electrode (GE) 153 The device of an AC Grounding Electrode system that establishes an electrical connection with earth is the ___________. A. AC Equipment Ground (ACEG) B. Telecommunications Bonding Conductor (TBC) C. Grounding Electrode Conductor (GEC) D. Grounding Electrode (GE) 154 The purpose of the equipment grounding (earthing) system is to: A. Establish a 0-volt reference for AC electrical power systems B. Maintain 0-volt on all equipment enclosures during normal operations C. Equalize potential between metallic surfaces within entrance facilities D. All the above 155 The purpose of the equipment grounding (earthing) system is to: A. Establish a 0-volt reference for AC electrical power systems B. Maintain 0-volt on all equipment enclosures during normal operations C. Equalize potential between metallic surfaces within entrance facilities D. All the above 156 The PBB serves as the dedicated extension of the ___________ for the telecommunications bonding infrastructure A. primary bonding busbar B. ac grounding (earthing) electrode system C. Equipment Grounding (Earthing) System D. Primary protector system 157 The PBB serves as the dedicated extension of the ___________ for the telecommunications bonding infrastructure A. primary bonding busbar B. ac grounding (earthing) electrode system C. Equipment Grounding (Earthing) System D. Primary protector system 158 Which of the following is likely NOT a part of a small telecommunication bonding system? A. PBB B. TEBC C. TBC D. TBB 159 Which of the following is likely NOT a part of a small telecommunication bonding system? A. PBB B. TEBC C. TBC D. TBB 160 In lieu of installing the TBB between the floors, a bonding conductor may be provided from each SBB to _________ if accessible. A. BBC B. Building steel C. Cable raceway on the same floor D. Grounding electrode conductor 161 In lieu of installing the TBB between the floors, a bonding conductor may be provided from each SBB to _________ if accessible. A. BBC B. Building steel C. Cable raceway on the same floor D. Grounding electrode conductor 162 The TBC connection between the grounding electrode system and the PBB should be within _______ to limit the impedance of the conductor. A. 1 m (3.3 ft) B. 3.5 (10 ft) C. 6.1 m (20 ft) D. 15.24 (50 ft) 163 The TBC connection between the grounding electrode system and the PBB should be within _______ to limit the impedance of the conductor. A. 1 m (3.3 ft) B. 3.5 (10 ft) C. 6.1 m (20 ft) D. 15.24 (50 ft) 164 Standards such as _______ recommend that a BBC be made on every third floor and the top floor of multi-story structures. A. TIA-606-B B. TIA-607-C C. NFPA 780 D. NEC 250-2 165 Standards such as _______ recommend that a BBC be made on every third floor and the top floor of multi-story structures. A. TIA-606-B B. TIA-607-C C. NFPA 780 D. NEC 250-2 166 Telecommunications circuit protectors are required by various codes for the function of A. Arresting surges that come from exposed circuit pairs B. Limiting damage caused by a fault in the equipment grounding system C. Providing a path to the equipment grounding system D. Equalizing ground potential rise 167 Telecommunications circuit protectors are required by various codes for the function of A. Arresting surges that come from exposed circuit pairs B. Limiting damage caused by a fault in the equipment grounding system C. Providing a path to the equipment grounding system D. Equalizing ground potential rise 168 Pulling Cables © BICSI 2018 The use of a swivel installed between the pull string or rope and the cable will minimize cable twisting. A. True B. False 170 The use of a swivel installed between the pull string or rope and the cable will minimize cable twisting. A. True B. False 171 High pair-count copper cables should be ordered with a factory-equipped ________. A. tracer wire B. pulling eye C. connector end D. splice housing 172 High pair-count copper cables should be ordered with a factory-equipped ________. A. tracer wire B. pulling eye C. connector end D. splice housing 173 What is the minimum bend radius for balanced twisted multi-pair cable? A. 4 times B. 6 times C. 10 times D. 20 times 174 What is the minimum bend radius for balanced twisted multi-pair cable? A. 4 times B. 6 times C. 10 times D. 20 times 175 Picking up used pull strings, storing cable, & disposing of all personal items, is an example of __________. A. Cable installation preparation B. Administration and close-out duties C. Identifying pull-points D. Effective communication 176 Picking up used pull strings, storing cable, & disposing of all personal items, is an example of __________. A. Cable installation preparation B. Administration and close-out duties C. Identifying pull-points D. Effective communication 177 The first step in Pulling Cable Set-up is: A. Set-up pull string or rope B. Post floor plans C. Secure the area D. Identify pull points 178 The first step in Pulling Cable Set-up is: A. Set-up pull string or rope B. Post floor plans C. Secure the area D. Identify pull points 179 No more than _____ 90-degree bends are permitted per ≈30 m (100 ft) if in conduit. A. 2 B. 3 C. 4 D. 5 180 No more than _____ 90-degree bends are permitted per ≈30 m (100 ft) if in conduit. A. 2 B. 3 C. 4 D. 5 181 A conduit with an internal diameter of 50 mm (2 in) or less must maintain a bend radius of at ______ the internal conduit diameter. A. 4 times B. 6 times C. 10 times D. 12 times 182 A conduit with an internal diameter of 50 mm (2 in) or less must maintain a bend radius of at ______ the internal conduit diameter. A. 4 times B. 6 times C. 10 times D. 12 times 183 The ITSIMM recommends marking cables ______ from the ends. A. 203 mm (8 in) B. 406 mm (16 in) C. 1 m (3.3 ft) D. 2 m (6.56 ft) 184 The ITSIMM recommends marking cables ______ from the ends. A. 203 mm (8 in) B. 406 mm (16 in) C. 1 m (3.3 ft) D. 2 m (6.56 ft) 185 What sheath listing should be used if the ceiling space is used as an environmental air plenum? A. CM B. CMG C. CMR D. CMP 186 What sheath listing should be used if the ceiling space is used as an environmental air plenum? A. CM B. CMG C. CMR D. CMP 187 Work area outlet heights are often installed at ___________________ AFF. A. 152 mm (6 in) to 254 mm (10 in) B. 203 mm (8 in) to 305 mm(12 in) C. 305 mm (12 in) to 406 mm (16 in) D. 375 mm (15 in) to 450 mm (18 in) 188 Work area outlet heights are often installed at ___________________ AFF. A. 152 mm (6 in) to 254 mm (10 in) B. 203 mm (8 in) to 305 mm(12 in) C. 305 mm (12 in) to 406 mm (16 in) D. 375 mm (15 in) to 450 mm (18 in) 189 When pulling backbone cabling in a vertical bottomup pull, using a swivel with a shear pin is recommended. A. True B. False 190 When pulling backbone cabling in a vertical bottomup pull, using a swivel with a shear pin is recommended. A. True B. False 191 A ________ is a type of temporary restraining method for installing cables vertically. A. pulling eye B. cable raceway C. D-ring D. rolling hitch 192 A ________ is a type of temporary restraining method for installing cables vertically. A. pulling eye B. cable raceway C. D-ring D. rolling hitch 193 The bend radius for intrabuilding optical fiber during installation is ___________________. A. 50 mm (2 in) B. 10 times the outside diameter C. 20 times the outside diameter D. 25 times the outside diameter 194 The bend radius for intrabuilding optical fiber during installation is ___________________. A. 50 mm (2 in) – optical fiber (up to 4 strands) B. 10 times the outside diameter C. 20 times the outside diameter D. 25 times the outside diameter 195 The preferred method for pulling tight buffered cables is to __________________. A. tie to a pulling eye B. use three half hitches around the cable sheath C. tie to the aramid yarn D. use the central strength member 196 The preferred method for pulling tight buffered cables is to __________________. A. tie to a pulling eye B. use three half hitches around the cable sheath C. tie to the aramid yarn D. use the central strength member 197 In the TR, the optical fiber cable service loop should reach the farthest corner, plus floor to ceiling. An additional _____ should be stored in the cabinet. A. 1 m (3.3 ft) B. 1.52 m (5 ft) C. 3 m (10 ft) D. 4.57 m (15 ft) 198 In the TR, the optical fiber cable service loop should reach the farthest corner, plus floor to ceiling. An additional _____ should be stored in the cabinet. A. 1 m (3.3 ft) – At outlet B. 1.52 m (5 ft) C. 3 m (10 ft) D. 4.57 m (15 ft) 199 Cable Terminations © BICSI 2018 What is the first step to perform pretermination functions? A. Review contract documents B. Organize cable by destination C. Form and dress cable D. Determine the length of slack required 201 What is the first step to perform pretermination functions? A. Review contract documents B. Organize cable by destination C. Form and dress cable D. Determine the length of slack required 202 When installing horizontal cable to a work area outlet, ___ of slack should be left after termination. A. 152 mm (6”) B. 203 mm (8”) C. 305 mm (12”) D. 406 mm (16”) 203 When installing horizontal cable to a work area outlet, ___ of slack should be left after termination. A. 152 mm (6”) B. 203 mm (8”) C. 305 mm (12”) D. 406 mm (16”) 204 Twisted-pair cable requires an ________________________ connection. A. APC B. UPC C. IDC D. IPC 205 Twisted-pair cable requires an ________________________ connection. A. APC – angled physical contact (optical fiber) B. UPC – ultra physical contact (optical fiber) C. IDC – insulation displacement contact D. IPC – insulation piercing contact 206 Match the tool with the termination hardware 207 Match the tool with the termination hardware 208 When stripping series 6 cable, how much length of conductor and dielectric should be exposed? A. 6.3 mm (0.25 in) B. 8.4 mm (0.33 in) C. 12.7 mm (0.50 in) D. 19 mm (0.75 in) 209 When stripping series 6 cable, how much length of conductor and dielectric should be exposed? A. 6.3 mm (0.25 in) B. 8.4 mm (0.33 in) C. 12.7 mm (0.50 in) D. 19 mm (0.75 in) 210 For cord management, how much space is recommended for horizontal cable management on a rack? A. One RU : two RU patch panel B. One RU : four RU patch panel C. Two RU : two RU patch panel D. Two RU : four RU patch panel 211 For cord management, how much space is recommended for horizontal cable management on a rack? A. One RU : two RU patch panel B. One RU : four RU patch panel C. Two RU : two RU patch panel D. Two RU : four RU patch panel 212 Testing Copper Media © BICSI 2018 Which phase of testing should include an inspection of all pathways and spaces? A. Phase 1 B. Phase 2 C. Phase 3 D. Phase 4 214 Which phase of testing should include an inspection of all pathways and spaces? A. Phase 1 B. Phase 2 C. Phase 3 D. Phase 4 215 Which phase of testing is often the most neglected? A. Phase 1 – Specification & visual verification B. Phase 2 – Testing with various equipment C. Phase 3 – Documentation D. Phase 4 – Labeling 216 Which phase of testing is often the most neglected? A. Phase 1 – Specification & visual verification B. Phase 2 – Testing with various equipment C. Phase 3 – Documentation D. Phase 4 – Labeling 217 When performing a wire map/continuity test utilizing a pair scanner, what is the first step? A. Calibrate the test set B. Enter the test limit criteria for the system under test C. Disconnect any active equipment from both ends of the cabling D. Attach a pair scanner to one end of cabling 218 When performing a wire map/continuity test utilizing a pair scanner, what is the first step? A. Calibrate the test set B. Enter the test limit criteria for the system under test C. Disconnect any active equipment from both ends of the cabling D. Attach a pair scanner to one end of cabling 219 What type of mis-wire does the following 568A test result illustrate? A. Transposed pair B. Split pair C. Crossed pair D. Reversed polarity 220 What type of mis-wire does the following 568A test result illustrate? A. Transposed pair B. Split pair C. Crossed pair D. Reversed polarity 221 Certification test sets are used to verify that an ICT cabling system meets the transmission performance requirements as specified in the applicable standard. A. True B. False 222 Certification test sets are used to verify that an ICT cabling system meets the transmission performance requirements as specified in the applicable standard. A. True B. False 223 A series 6 cable has 10-ohm max resistance per 300 ft. If you test the system with an ohm meter and a 75-ohm resistor, what should your meter read? A. 10 ohms B. 30 ohms C. 75 ohms D. 85 ohms 224 A series 6 cable has 10-ohm max resistance per 300 ft. If you test the system with an ohm meter and a 75-ohm resistor, what should your meter read? A. 10 ohms B. 30 ohms C. 75 ohms D. 85 ohms 225 According to the ITSIMM, what is the first step when troubleshooting a cabling system? A. Contact end user before starting work and ask specific questions B. Perform a visual inspection C. Gather relevant information D. Perform repair work 226 According to the ITSIMM, what is the first step when troubleshooting a cabling system? A. Contact end user before starting work and ask specific questions B. Perform a visual inspection C. Gather relevant information D. Perform repair work 227 The acronym VIRT stands for Verify, _____, Repair, Test. A. Identify B. Isolate C. Interpret D. Interject 228 The acronym VIRT stands for Verify, _____, Repair, Test. A. Identify B. Isolate C. Interpret D. Interject 229 Firestopping Practices © BICSI 2018 The most common fire protection principal is: 1. Compartmentation 2. Detection 3. Annunciation 4. Suppression 231 The most common fire protection principal is: 1. Compartmentation 2. Detection 3. Annunciation 4. Suppression 232 A listed assembly is based on the: Fire barrier type, ________, Penetrating item(s), and firestop material(s). A. Mechanics B. Rating C. Design D. Construction 233 A listed assembly is based on the: Fire barrier type, ________, Penetrating item(s), and firestop material(s). A. Mechanics B. Rating C. Design D. Construction 234 This type of firestop system absorbs heat, which prevents the temperature from rising on the other side of the fire barrier. A. Intumescent B. Endothermic C. Ablative D. Elastomeric 235 This type of firestop system absorbs heat, which prevents the temperature from rising on the other side of the fire barrier. A. Intumescent B. Endothermic C. Ablative D. Elastomeric 236 This type of firestop system develops a hard char that allows a soft firestop to become rigid to help it withstand high-pressure gases and the force from a hose stream. A. Intumescent B. Endothermic C. Ablative D. Elastomeric 237 This type of firestop system develops a hard char that allows a soft firestop to become rigid to help it withstand high-pressure gases and the force from a hose stream. A. Intumescent B. Endothermic C. Ablative D. Elastomeric 238 What does BICSI stand for? 239 What does BICSI stand for? Building Industry Consultants Services International •Lead the information and communications technology industry with excellence in publications, education and knowledge assessment. •Formed in 1977 •Serves over 25,000 members globally 240 GOOD LUCK! © BICSI 2018
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )