4-1. What is the principal difference between a synchronous
machine and an induction machine?
Answer:
ο·
Synchronous machine: Rotor rotates exactly at
synchronous speed; requires DC excitation for rotor
field.
ο·
Induction machine: Rotor rotates slightly slower than
synchronous speed (slip); rotor field is induced, no
external DC excitation.
4-2. Why does switching the current flows in any two phases
reverse the direction of rotation of a stator's magnetic field?
Answer: Reversing any two phases changes the phase
sequence, which reverses the direction of the rotating
magnetic field.
4-3. What is the relationship between electrical frequency
and magnetic field speed for an AC machine?
Answer: Synchronous speed ππ (rpm) is given by ππ =
ππππ
π·
,
where π is electrical frequency (Hz) and π· is number of poles.
4-4. What is the equation for the induced torque in an AC
machine?
Answer:
General form:
ππππ
= π ⋅ π©πΉ ⋅ π©πΊ ⋅ π¬π’π§β‘πΉ
where π©πΉ is rotor magnetic field, π©πΊ is stator magnetic
field, πΉ is the angle between them, and π is a constant.
For induction machines, torque is proportional to rotor
current and air-gap flux.
5-1. Why is the frequency of a synchronous generator locked into
its rate of shaft rotation?
Answer: Because the generated AC frequency is directly
proportional to the rotational speed and number of poles: π =
π⋅π
.
120
5-2. Why does an alternator’s voltage drop sharply when it is
loaded down with a lagging load?
Answer: Armature reaction is demagnetizing, and voltage drops
across synchronous reactance and resistance increase.
5-3. Why does an alternator’s voltage rise when it is loaded down
with a leading load?
Answer: Armature reaction is magnetizing, strengthening the net
flux.
5-4. Sketch the phasor diagrams and magnetic field relationships
for a synchronous generator operating at (a) unity power factor,
(b) lagging power factor, (c) leading power factor.
Answer:
(a) πΌπ΄ in phase with ππ , πΈπ΄ leads ππ by πΏ.
(b) πΌπ΄ lags ππ , πΈπ΄ larger magnitude and larger πΏ.
(c) πΌπ΄ leads ππ , πΈπ΄ may have smaller πΏ and altered magnitude.
5-5. Explain just how the synchronous impedance and armature
resistance can be determined in a synchronous generator.
Answer:
ο·
π
π΄ from DC test.
ο·
ππ from open-circuit test (OCC) and short-circuit test
(SCC): ππ = πΈππ /πΌπ π at same field current.
ο·
ππ ≈ √ππ2 − π
π΄2 .
5-6. Why must a 60-Hz generator be derated if it is to be operated
at 50 Hz? How much derating must be done?
Answer: Lower frequency reduces speed, which reduces cooling;
core losses may also change. Derating ≈ 50/60 ≈ 83% of original
rating.
5-7. Would you expect a 400-Hz generator to be larger or smaller
than a 60-Hz generator of the same power and voltage rating?
Why?
Answer: Smaller; higher frequency allows more power per unit
size due to reduced core and winding size for same voltage.
5-8. What conditions are necessary for paralleling two
synchronous generators?
Answer: Same voltage, frequency, phase sequence, and phase
angle.
5-9. Why must the oncoming generator on a power system be
paralleled at a higher frequency than that of the running system?
Answer: So that it can take on load immediately after
synchronization (higher frequency means it will slow down slightly
and share real power).
5-10. What is an infinite bus? What constraints does it impose on
a generator paralleled with it?
Answer: Infinite bus is a large system with constant voltage and
frequency. It fixes voltage and frequency; the generator can only
control its real and reactive power output.
5-11. How can the real power sharing between two generators be
controlled without affecting the system’s frequency? How can the
reactive power sharing between two generators be controlled
without affecting the system’s terminal voltage?
Answer: Adjust governor setpoints together to shift power
sharing; adjust field currents together to shift reactive power
sharing.
5-12. How can the system frequency of a large power system be
adjusted without affecting the power sharing among the system’s
generators?
Answer: Change all governor setpoints together by the same
amount.
5-13. How can the concepts of Section 5.9 be expanded to
calculate the system frequency and power sharing among three
or more generators operating in parallel?
Answer: Use load-frequency characteristics (droop curves) for
each generator and solve simultaneously for system frequency
and individual outputs.
5-14. Why is overheating such a serious matter for a generator?
Answer: Overheating damages insulation, reduces lifespan, and
can cause immediate failure.
5-15. Explain in detail the concept behind capability curves.
Answer: Capability curves show safe operating limits for real and
reactive power based on heating (armature and field current) and
stability limits.
5-16. What are short-time ratings? Why are they important in
regular generator operation?
Answer: Short-time ratings allow higher output for brief periods
(e.g., overloads). Important for handling temporary load peaks
without oversizing the machine.
Chapter 6: Synchronous Motors
6-1. What is the difference between a synchronous motor and a
synchronous generator?
Answer: Motor converts electrical to mechanical power;
generator does the reverse. Same machine, different mode of
operation.
6-2. What is the speed regulation of a synchronous motor?
Answer: 0% — it runs at constant synchronous speed regardless
of load.
6-3. When would a synchronous motor be used even though its
constant-speed characteristic was not needed?
Answer: When power factor correction is needed (operating as a
synchronous condenser).
6-4. Why can't a synchronous motor start by itself?
Answer: The rotating magnetic field runs at synchronous speed
immediately; the rotor inertia prevents it from catching up from
standstill.
6-5. What techniques are available to start a synchronous motor?
Answer: Use an auxiliary motor, start as induction motor using
amortisseur windings, or use variable-frequency drive.
6-6. What are amortisseur windings? Why is the torque produced
by them unidirectional at starting, while the torque produced by
the main field winding alternates direction?
Answer: Amortisseur windings are damper bars in the rotor. They
produce induction-motor-like unidirectional torque during starting
because of slip; main field torque alternates if not synchronized.
6-7. What is a synchronous capacitor? Why would one be used?
Answer: A synchronous motor running at no-load, overexcited to
supply leading reactive power. Used for power factor correction.
6-8. Explain, using phasor diagrams, what happens to a
synchronous motor as its field current is varied. Derive a
synchronous motor V curve from the phasor diagram.
Answer: Varying field current changes πΈπ΄ and thus armature
current and power factor. V curve plots πΌπ΄ vs πΌπΉ for constant
load—minimum current at unity PF.
6-9. Is a synchronous motor's field circuit in more danger of
overheating when it is operating at a leading or at a lagging power
factor? Explain, using phasor diagrams.
Answer: Leading PF (overexcited) increases field current, risking
field winding overheating.
6-10. A synchronous motor is operating at a fixed real load, and
its field current is increased. If the armature current falls, was the
motor initially operating at a lagging or a leading power factor?
Answer: Initially lagging PF (underexcited). Increasing πΌπΉ brings it
toward unity PF, reducing πΌπ΄ .
6-11. Why must the voltage applied to a synchronous motor be
derated for operation at frequencies lower than the rated value?
Answer: To avoid excessive flux and core saturation, since π/
π should be constant to maintain flux levels.
Chapter 7: Induction Motors
7-1. What are slip and slip speed in an induction motor?
Answer: Slip π =
ππ π¦ππ −ππ
ππ π¦ππ
; slip speed = ππ π¦ππ − ππ .
7-2. How does an induction motor develop torque?
Answer: Rotor conductors cut stator rotating magnetic field,
inducing currents that interact with the field to produce torque.
7-3. Why is it important for an induction motor to operate at
synchronous speed?
Answer: At synchronous speed, slip = 0, so no induced rotor
current and torque = 0. Motor operates just below synchronous
speed under load.
7-4. Sketch and explain the shape of a typical induction motor
torque-speed characteristic curve.
Answer: Curve shows zero torque at sync speed, max torque at
some slip, high starting torque, stable operating region for normal
loads.
7-5. What equivalent circuit element has the most direct control
over the speed at which the pullout torque occurs?
Answer: Rotor resistance π
2 . Increasing it moves pullout torque
to higher slip.
7-6. What is a deep-bar cage rotor? Why is it used? What NEMA
design class(es) can be built with it?
Answer: Rotor bars deeper than standard, increasing resistance
at start due to skin effect. Used for high starting torque; NEMA
Design B or C.
7-7. What is a double-cage cage rotor? Why is it used? What
NEMA design class(es) can be built with it?
Answer: Two layers of rotor bars — high resistance outer cage
for starting, low resistance inner cage for running. Used for high
starting torque, good efficiency; NEMA Design B or C.
7-8. Describe the characteristics and uses of wound-rotor
induction motors and of each NEMA design class of cage motors.
Answer:
ο·
Wound-rotor: External rotor resistance allows speed control,
high starting torque.
ο·
NEMA Design A: Normal starting torque, low slip.
ο·
Design B: Normal starting torque, normal slip.
ο·
Design C: High starting torque.
ο·
Design D: Very high starting torque, high slip.
7-9. Why is the efficiency of an induction motor (wound-rotor or
cage) so poor at high slip?
Answer: High rotor copper losses (ππ
πΆπΏ = π ππ΄πΊ ).
7-10. Name and describe four means of controlling the speed of
induction motors.
Answer:
1. Change poles (pole changing winding).
2. Change supply frequency (VFD).
3. Change rotor resistance (wound rotor).
4. Change terminal voltage (limited range).
7-11. Why is it necessary to reduce the voltage applied to an
induction motor as electrical frequency is reduced?
Answer: To maintain constant air-gap flux (π/π constant) and
avoid saturation.
7-12. Why is terminal voltage speed control limited in operating
range?
Answer: Torque ∝ π 2 ; too low voltage causes torque shortage
and overheating.
7-13. What are starting code factors? What do they say about the
starting current of an induction motor?
Answer: NEMA code letters indicate locked-rotor kVA/hp. Higher
code = higher starting current.
7-14. How does a resistive starter circuit for an induction motor
work?
Answer: Adds resistance in series with stator or rotor to reduce
starting current and increase starting torque (for wound rotor).
7-15. What information is learned in a locked-rotor test?
Answer: Equivalent rotor resistance and leakage reactance at
starting conditions.
7-16. What information is learned in a no-load test?
Answer: Rotational losses, magnetizing reactance, and core loss
resistance.
7-17. What actions are taken to improve the efficiency of modern
high-efficiency induction motors?
Answer: More copper, better steel, improved cooling, reduced air
gap, optimized design.
7-18. What controls the terminal voltage of an induction generator
operating alone?
Answer: Capacitive VAR supply for excitation; load and
capacitance determine voltage.
7-19. For what applications are induction generators typically
used?
Answer: Small wind turbines, waste energy recovery, where grid
connection exists for VARs.
7-20. How can a wound-rotor induction motor be used as a
frequency changer?
Answer: By injecting slip-frequency voltage into rotor circuits to
produce different stator or rotor output frequency.
7-21. How do actuator voltage-frequency patterns affect the
torque-speed characteristics of an induction motor?
Answer: V/f control maintains constant flux for constant torque
below base speed; above base speed, voltage constant reduces
torque capability.
7-22. Describe the major features of the solid-state induction
motor drive featured in Section 7.10.
Answer: PWM inverter, V/f control, speed feedback, soft start,
regenerative braking capability.
7-23. Two 450 V, 100-hp induction motors are manufactured. One
is designed for 50-Hz operation, and one is designed for 60-Hz
operation, but they are otherwise similar. Which of these
machines is larger?
Answer: The 50-Hz motor is larger because lower frequency
requires more turns and/or larger core for same voltage and
power.
7-24. An induction motor is running at the rated conditions. If the
shaft load is now increased, how do the following quantities
change?
(a) Mechanical speed → Decreases
(b) Slip → Increases
(c) Rotor induced voltage → Increases
(d) Rotor current → Increases
(e) Rotor frequency → Increases
(f) ππ
πΆπΏ → Increases
(g) Synchronous speed → Unchanged