CL 333 Chemical Engineering Lab-2 Experiment Number HT 306 Title Shell and Tube Heat Exchanger Sub-group Code B3a Date of Experiment 11/08/2025 Date of Report Submission 18/08/2025 Roll Number Name Responsibility owned (data, analysis, plots, report, none) 23B0404 Minal Bhojasia Hypothesis 23B0383 Shantanu Saharan Aim, Procedure 23B0307 Kadam Gaurav Kailas Calculation, Error Analysis 23B0361 Gokul M Sources of error, Plots (For use by examiners only) Criterion Calculations Graphical plots Hypothesis testing Report quality Initials with date R&P TA initials with date TA assigned marks Faculty assigned marks Contents 1. Objective 2. Aim 3. Theory 4. Procedure 5. Apparatus Used 6. Data 7. Sample Calculations 8. Error Analysis 9. Observations 10. Sources of error 11. Hypothesis 12. Plots 13. Conclusion Shell and Tube Heat Exchanger Objective On successful completion of this experiment, you should be able to 1. Identify key components and lines in a shell and tube heat exchanger (SATHE), 2. Operate a SATHE, controlling the flow rates and hot fluid inlet temperature, 3. Carry out performance calculations for the SATHE by theoretical and experimental methods, 4. hypothesize possible reasons why the experimental observation is different from the theoretically expected values. Introduction The shell-and-tube heat exchanger is a versatile and ubiquitous piece of equipment for heat transfer. They are widely used as oil coolers, power condensers, preheaters in power plants, steam generators in nuclear power plants, in process applications, and the chemical industry. A large cylindrical shell houses a collection (bank) of tubes. Fluid motion occurs both on the shell (external flow) and the tube side (confined or internal flow). A common terminology in heat exchangers is “passes”, Eg, 1-shell pass, 2-tube passes. A pass is the number of times the fluid traverses from one end to another. This is achieved using a 180 ° bend in the direction of flow. The fluid allocation in the heat exchanger to the shell or tube side depends on multiple factors, such as the material of construction and the properties of the fluid. Corrosive fluids and fouling fluids are flown through the tube side since it is easy to replace the tubes for cleaning, and the material of construction used for the shell side is expensive. High temperature, less viscous and fluids with high-pressure drop are preferably allocated on the tube side. Theory and Principles Heat exchanger calculations involve two major types, Bergman et al. [2011]: 1. Design: Finding the area of heat transfer, given a knowledge of the flow rates and inlet temperatures, and a specified desired outlet temperature (for the cold or hot fluid). 3 2. Performance: Finding the outlet temperature of one of the streams, for a given heat exchanger (area) and known inlet temperatures and flow rates. There are also two commonly used algorithms to solve the above problems. 1. LMTD method: This is used mainly for the design problem. For the performance problem, this needs an iterative solution. 2. ε-NTU method: The effectiveness (ε) and the number of transfer units (NTU) can also be used to solve both problems. Though this method is not as simple as the LMTD method, it can be used to solve both problems in a non-iterative sequence of steps. Heat exchangers involve transport of heat through multiple resistances, and the local resistance depends on various factors such as the local boundary layer thickness, presence of fouling, and the thermal conductivity of the wall that separates the shell-side fluid from the tube-side fluid. A macroscopic heat balance across the heat exchanger leads to the definition of an overall heat transfer coefficient (which is inversely proportional to the overall resistance to heat transfer). 𝐷 '' 1 𝑈𝐴 = 1 ℎ𝑖 𝐴𝑖 + 𝑅𝑓,𝑖 𝐴𝑖 + ln( 𝐷𝑜 ) 𝑖 2 π𝑘 𝐿 + 𝑅''𝑓 𝑜 , 𝐴𝑜 1 + ℎ 𝐴 𝑜 𝑜 where, U is the overall heat transfer coefficient, hi is the inside heat transfer coefficient, ho is the outside heat transfer coefficient, 𝐴𝑖 is the inside heat transfer area, 𝐴𝑜 is the outside heat trandfer area, A is the either of the two areas depending on whether U is inner/outer (or hot/cold) such that 𝑈𝑖 𝐴𝑖 = 𝑈𝑜𝐴𝑜, (𝑅''𝑓,𝑖 𝑅''𝑓,𝑜) are the area-based fouling resistances, (Di, Do) are the inner and outer diameter of the tube, respectively, k is the thermal conductivity of the tube wall, L is the thickness of the tube, (hi, h[o ) are the convective heat transfer coefficients. Experiment Procedure These are the broad steps. Read the entire manual to plan detailed steps for your experiment. 1. Inspect the assembly and identify (a) hot fluid inlet and outlet (b) cold fluid inlet and outlet 4 (c) flow rate control and measurement of hot and cold fluids (d) bypass line from the bypass valve (e) heater temperature control 2. Read the startup, control, and shutdown procedures 3. Note down the least number of measurements. 4. Set the hot inlet temperature at the given value 5. Adjust the flow rates to match the nearest multiple of the least count 6. After the steady state is attained, note down all the measured variables. 7. Repeat the above steps for another flow rate around the given value. 8. Interpolate for the outlet temperature at the given value of the inlet flow rate. 9. Find the error in the estimation of the temperature (using the method of propagation of errors). 10. Compare the interpolated value with the theoretical predictions. 11.Analyse if the deviation from the theory is significant (i.e., beyond experimental error) 12. Hypothesize reasons if the deviation is significant. Apparatus Used Main Equipment: 1. Shell and tube heat exchanger (SATHE) assembly 2. Water tank (hot water source) 3. Electric heater with temperature controller 4. Hot water circulation pump 5. Cold water inlet connection (tap water supply) 6. Cold water outlet line (to drain) Flow Control & Measurement: 7. Rotameters (for measuring hot and cold fluid flow rates) 8. Flow control valves (V1 to V6) 9. Bypass valve (V3) Temperature Measurement: 10. Thermocouples or temperature sensors (T1, T2, T3, T4 — for hot/cold inlet outlet) 11. Thermostat display panel (shows inlet/outlet temperatures) Piping & Fittings: 12. Hot fluid inlet and outlet lines 13. Cold fluid inlet and outlet lines 14. Bypass line from bypass valve 15. Connecting pipelines and joints Electrical & Control: 16. Control panel with switches and indicators 17. Main power supply connection Raw Data Set Reservoir temperature= 50 0C T1 : Hot in T2 : Hot out T3 : Cold in T4 : Cold out Hot Flow Rate (LPH) Cold Flow Rate (LPH) T1 T2 T3 T4 75 100 49.9 38.5 30.8 37.2 100 100 49.8 41 30.9 39.4 150 100 49.7 42.4 31.1 40.1 200 100 49.8 44.3 31.2 41.7 100 50 50.1 44.3 31.4 43.2 100 100 49.4 41.8 31.3 40.5 100 150 49.7 39.8 31.1 37.7 100 200 49.6 38.9 31.1 36.4 49.72 41.78 31.15 39.52 Mean Sample Calculations Constant used: ● No of Plates= N =24 ● Length of Tube= l =0.5m ● Inner Diameter= Di =0.013m ● Outer Diameter= Do = 0.016m ● Area = A = π * 𝐷𝑖 * 𝐿 * 𝑁 = 3.14 * 0.013 * 0.5 * 24 =0.49 m2 To demonstrate the sample calculation for 75 LPH Hot water and 100 LPH Cold water flow rate: Average temp of cold water = 𝑇𝑐 = (𝑇3 + 𝑇 4)/2 = (30. 8 + 37. 2)/2 = 34 0C Average temp of Hot water= 𝑇ℎ = (𝑇1 + 𝑇2)/2 = (49. 9 + 38. 5)/2 = 44. 2 0C At these 𝑇𝑐 and 𝑇ℎ we find the value of the following constants from Engineering Toolbox Reference: 3 ● ρ𝑐 = 994. 4 𝑘𝑔/𝑚 ● ρℎ = 990. 57 𝑘𝑔/𝑚 (cold water at 𝑇𝑐) 3 (hot water at 𝑇ℎ) ● 𝐶𝑝𝑐 = 4180 𝐽/𝑘𝑔. 𝐾 (heat capacity of cold water at 𝑇𝑐) ● 𝐶𝑝ℎ = 4180 𝐽/𝑘𝑔. 𝐾 (heat capacity of hot water at 𝑇ℎ) ● µ𝑐=0.0007342 Ns/m2 (viscosity of cold water 𝑇𝑐) 2 ● µℎ = 0. 0006056 𝑁𝑠/𝑚 (viscosity of cold water 𝑇ℎ) ● 𝑘𝑐 = 0.621 W/m.K (Thermal conductivity of cold water at 𝑇𝑐) ● 𝑘ℎ = 0.634 W/m.K (Thermal conductivity of hot water at 𝑇ℎ) The value of these physical quantities for all the runs was found and tabulated as below: Hot Flow Rate (LPH) Cold Flow Rate (LPH) rhoc(kg/m 3) Cph(J/ kg K) Cpc(J /kg K) kh(W/ mK) kc(W/m K) mu h(Ns/m 2) mu c(Ns/ m2) 990.57 994.4 4180 4180 0.634 0.621 0.0006 056 0.000 7342 990.07 994.01 4180 4180 0.634 0.621 0.0005 928 0.000 7176 989.8 993.86 4180 4180 0.634 0.621 0.0005 861 0.000 7113 989.37 993.56 4180 4180 0.634 0.621 0.0005 759 0.000 6996 989.3 993.25 4180 4180 0.634 0.621 0.0005 744 0.000 6882 989.99 993.75 4180 4180 0.634 0.621 0.0005 907 0.000 7072 990.35 994.27 4180 4180 0.634 0.621 0.0005 997 0.000 7284 0.621 0.0006 051 0.000 7379 rho h (kg/m3) 75 100 100 100 150 100 200 100 100 50 100 100 100 150 100 200 990.55 Mass Flow rate of hot water= Mh= 994.49 𝐹ℎ×ρℎ 3600×1000 4180 75 = 1000 * 4180 990.57 3600 0.634 = 0. 0206 (𝐾𝑔/𝑠𝑒𝑐) 𝐻𝑒𝑎𝑡 𝑡𝑟𝑎𝑛𝑠𝑓𝑒𝑟 𝑟𝑎𝑡𝑒 𝑓𝑜𝑟 ℎ𝑜𝑡 𝑤𝑎𝑡𝑒𝑟= 𝑄ℎ= 𝑀ℎ * 𝐶𝑝ℎ * ( 𝑇1 − 𝑇2) = 983. 38 𝑊 𝐹 ×ρ 𝑐 𝑐 Mass flow rate of cold water= 𝑀𝑐 = 3600×1000 = 100 1000 994.4 * 3600 = 0. 0276(𝐾𝑔/𝑠𝑒𝑐) 𝐻𝑒𝑎𝑡 𝑡𝑟𝑎𝑛𝑠𝑓𝑒𝑟 𝑟𝑎𝑡𝑒 𝑓𝑜𝑟 ℎ𝑜𝑡 𝑤𝑎𝑡𝑒𝑟 = 𝑄𝑐 = 𝑀𝑐 * 𝐶𝑝𝑐 * (𝑇4 − 𝑇3) = 738. 94 𝑊 𝑄= 𝑄𝑐+𝑄ℎ 2 = 983.38+738.9 2 = 861. 16 𝑊 ∆𝑇1 = 𝑇1 −𝑇4 = 49. 9 − 37. 2 = 12. 7 ∆𝑇2 = 𝑇2 −𝑇3 = 38. 5 − 30. 8 = 8 LMTD Method: 0 𝐶 0 𝐶 ∆𝑇1−∆𝑇2 ∆𝑇𝐿𝑀𝑇𝐷 = ∆𝑇𝑀 = ∆𝑇 𝑙𝑛( ∆𝑇1 ) = 9. 99 2 Since we have single shell pass and 2 tube pass heat exchanger, we will need to account for the same using a correction factor F that is calculated as follows: 𝑃= 𝑇ℎ,𝑜𝑢𝑡−𝑇ℎ,𝑖𝑛 𝑇𝑐,𝑖𝑛−𝑇ℎ,𝑖𝑛 𝑇 −𝑇 𝑇 −𝑇 𝑇 −𝑇 = 𝑇2−𝑇1 = 0. 5968 𝑅 = 𝑇 𝑐,𝑖𝑛 −𝑇𝑐,𝑜𝑢𝑡 = 𝑇3−𝑇4 = 0. 56 4 1 ℎ,𝑜𝑢𝑡 ℎ,𝑖𝑛 2 1 By using software for calculating LMTD Correction Factor and get the value of F for corresponding P and R values. We got F=0.8612 𝑄 𝑈 = 𝐴 * 𝐹 * ∆𝑇 𝐿𝑀𝑇𝐷 = 861.16 0.49* 0.86* 9.99 2 = 204. 23 𝑊/𝑚 𝐾 In order to use LMTD method to get the outlet temperature, we will have to take a guess value of the T, and then use it to calculate U, and use that value of U to recalculate the missing T. We continue to iterate over this cycle till two consecutive values of T match and converge. Interpolation to calculate hot stream outlet temperature: We will just equate 𝑄𝑐 and 𝑄ℎ to get the outlet temperature, 𝑀 0.0276 𝑇2 = 𝑇1 − ( 𝑇4 − 𝑇3) * 𝑀𝑐 = 49. 9 − (37. 2 − 30. 8) * 0.0206 = 39. 74 ℎ The following table shows these calculations for the rest of the data: ε-NTU Method: 𝐶ℎ = 𝑀ℎ * 𝐶𝑝ℎ = 0. 0206 * 4180 = 86. 2 𝐽/𝐾𝑠 𝐶𝑐 = 𝑀𝑐 * 𝐶𝑝𝑐 = 0. 0276 * 4180 = 115. 6 𝐽/𝐾 𝑠 𝑀𝑖𝑛(𝐶 ,𝐶 ) 86.2 This implies, 𝐶𝑟 = 𝑀𝑎𝑥( 𝐶ℎ ,𝐶𝑐 ) = 115.6 = 0. 75 ℎ 𝑐 𝑄𝑚𝑎𝑥 = 𝐶𝑚𝑖𝑛 * (𝑇ℎ,𝑖𝑛 − 𝑇𝑐,𝑖𝑛) = 86. 2 * (49. 9 − 30. 8) = 1647. 60 𝑊 𝑈𝐴 𝐶𝑚𝑖𝑛 𝑁𝑇𝑈 = 0.49 = 204. 23 * 86.2 = 1. 16 𝑢𝑛𝑖𝑡𝑠 For one shell pass (2 tube passes ), the relation between εNTU is: ε = 2 * [( 1 + 𝐶𝑟 + 2 1 + 𝐶𝑟 ) ( 1+ 𝑒𝑥𝑝(−𝑁𝑇𝑈1×( 1− 𝑒𝑥𝑝(−𝑁𝑇𝑈1×( 2 1+ 𝐶𝑟 )) −1 ] = 0. 53 2 1+ 𝐶𝑟 )) 𝑄 = ε * 𝑄𝑚𝑎𝑥 = 0. 53 * 1647. 60 = 875. 840 W 𝑄 Thus , 𝑇ℎ,𝑜𝑢𝑡 = 𝑇2 = 𝑇1 − 𝑀 𝐶 ℎ = 49. 9 − 𝑝ℎ 875.84 0.0206*4180 = 39. 74 °𝐶 The ε-NTU method calculations done for the rest of the runs are given in the table below: Reynolds and Nusselt Number Calculation : 4*𝑀 𝑅𝑒ℎ = π* µ *ℎ𝐷 = ℎ 𝑃𝑟ℎ = 𝐶𝑝ℎ* µℎ 𝐾ℎ 𝑖 = 4*0.0206 3.14* 0.0006056* 0.013 4180*0.0006056 0.634 = 3337. 52 = 3. 99 Based on the hot side, 𝑈ℎ* 𝐷𝑖 Experimental 𝑁𝑢ℎ𝑒𝑥𝑝 = 𝑘ℎ = 204.32*0.013 0.634 = 4. 19 Theoretical Nu calculations are based on the correlation: 𝑓*(𝑅𝑒−1000)* 𝑃𝑟 𝑁𝑢 = 2 8*(1+12.7* 𝑓 *(𝑝𝑟 3 −1)) 8 6 , 𝑓𝑜𝑟 3000 < 𝑅𝑒 < 5 * 10 , 0. 5 < 𝑃𝑟 < 2000 −2 Where 𝑓 = (0. 79 * 𝑙𝑛(𝑅𝑒) − 1. 64) =0.0439 Thus , on calculating Theoretical Nu =21.12 These calculations have been done for the rest of the runs and are given in the table below: Error Analysis Errors in measurements= Least Count ∆𝑇1 = ∆𝑇2 = ∆𝑇3 = ∆𝑇4 = 0. 1 0C ∆𝐹𝑐 = ∆𝐹ℎ = 5 𝐿𝑃𝐻 Substituting the above values in the following equations, we can obtain error in other quantities: Calculating for Fh= 75 LPH , Fc= 100 LPH 2 2 2 2 ∆𝑇𝑐 = 1 2 ∆𝑇3 + ∆𝑇4 = 0.071 ∆𝑇ℎ = 1 2 ∆𝑇1 + ∆𝑇2 =0.071 ∆𝑀ℎ = ∆𝐹ℎ = 5 𝐿𝑃𝐻 = 0. 0013 𝑘𝑔/𝑠 ∆𝑀𝑐 = ∆𝐹𝑐 = 5 𝐿𝑃𝐻 = 0. 0013 𝑘𝑔/𝑠 2 = 𝑄𝑐. ( ) ( ) ( ) ( ) 1 2 ∆𝑄ℎ = 𝑄ℎ. ∆𝑄𝑐 2 ∆𝑀ℎ ∆𝑄 = 2 ∆𝑇ℎ + 𝑀ℎ 𝑇1−𝑇2 2 ∆𝑀𝑐 𝑀𝑐 2 ∆𝑇𝑐 + = 𝑇4−𝑇3 38. 42 2 ∆𝑄ℎ + ∆𝑄𝑐 =36. 95 2 2 2 2 ∆(∆𝑇1) = ∆𝑇1 + ∆𝑇4 = 0. 14 ∆(∆𝑇1) = ∆𝑇3 + ∆𝑇2 = 0. 14 ( ∆(𝑇𝑙𝑚𝑡𝑑) = 𝑇𝑙𝑚𝑡𝑑 * ∆𝐴 = 𝐴. = 63. 13 ∆𝐿 2 𝐿 ∆(∆𝑇1) ∆𝑇1 2 ) ( + ∆(∆𝑇2) ∆𝑇2 2 ) = 19. 78 ∆𝐷𝑖 2 𝐷𝑖 ( ) + ( ) = 0. 10 ∆𝑈 = 𝑈. ∆𝑄 2 + 𝑄 ∆𝐴 2 + 𝐴 ( ) ( ) ∆𝑁𝑇𝑈 = 𝑁𝑇𝑈. ∆𝑈 2 𝑈 ( ∆(∆𝑇𝑙𝑚𝑡𝑑) ∆(𝑇𝑙𝑚𝑡𝑑) ∆𝐴 2 𝐴 ( ) +( ) +( ∆𝑀ℎ ∆𝐶𝑚𝑖𝑛 = 𝐶𝑚𝑖𝑛 * ∆𝑀ℎ = 263. 69 ∆𝑁𝑈 = 𝑁𝑈. ∆𝑈 2 𝑈 ∆𝐷 2 𝐷 ( ) + ( ) = 0. 87 2 ) = 42. 62 ∆𝐶𝑚𝑖𝑛 2 𝐶𝑚𝑖𝑛 ) = 0. 35 Hypothesis 1. Overall heat transfer increases with an increase in flow rate Explanation: When the flow rate of one or both fluids is increased, turbulence is enhanced and the thermal boundary layer becomes thinner. As a result, the heat transfer coefficient improves, which promotes greater heat exchange between the fluids 2. Minimizing the heat lost to the surroundings can help achieve a value of U closer to the theoretical value. Explanation: Heat lost to the surrounding can lead to discrepancies between Qh & Qc. Heat lost leads to less heat being absorbed by the cold fluid than the total heat lost by the hot fluid, leading to a value of U that doesn’t reflect the ideal scenario. Proper measurement can minimize the losses and give a better measurement. 3. Non uniform flow distribution within the heat exchanger can affect heat transfer efficiency and lead to errors in calculation. Explanation: Uneven flow distribution can lead to areas with higher or lower heat transfer rates, affecting the overall heat transfer performance 4. Heat loss to the surroundings lowers the value of heat absorbed by the cold water. There is a significant heat loss from the system to surroundings in the form of convection, radiation heat transfer. The metallic plates in contact with fluid get heated up and heat energy consumed offering conductive thermal resistance. Also there is heat transfer resistance in the fluid side. Prediction: Tf of cold water is lowered due to heat loss, hence lowering the value of Qc and Q and the value of overall heat transfer coefficient. Testing: For Fh = 50 LPH case, the value of T4 = 36.2 °C , Tc = 34.2°C. Assuming that there is no heat loss from the system, let's assume the temperature of the cold water rises to T4 = 40 °C, in that case Tc= 36.1. The value of relative error in Nusselt number is reduced Testing: For Fh = 75 LPH case, the value of T4 = 37.2 °C , Tc = 34°C. Assuming that there is no heat loss from the system, lets assume the temperature of the cold water rises to T4 = 40 °C, in that case Tc= 35.4. The value of relative error in Nusselts number is reduced to 53% from 80.1%. This explains the significant difference between the experimental and theoretical values. Thus, this hypothesis is acceptable. 5. The value of correction factor used for calculation of overall heat transfer coefficient is not accurate. The value of the friction factor used in calculations is generally obtained from experimental plots available in the literature by determining the parameters P and R. However, these parameters are themselves subject to uncertainties, especially due to errors in temperature measurement. As a result, the approximation of the friction factor from such plots can introduce deviations in the calculations. This leads to discrepancies between the experimentally obtained and theoretically predicted values of the Nusselt number. Prediction: Using accurate values of friction factor and minimise this deviation and lead to accurate results. Testing: For Fh = 50 LPH, let s assume that the friction factor is 0.7 than its value of 0.82. In that case, the relative error in theoretical and experimental Nusselts number reduces to 76% from 80.1%. This is intuitive as overall heat transfer coefficient increases on lowering the friction factor and hence experimental Nusselts number increases. Thus, this hypothesis is acceptable. Conclusions 1. The values of T2 obtained experimentally, theoretically are: 2.The values of Nu theoretical, experimental, U experimental and NTU are: Sources of Error 1. The pipe connections from the hot water reservoir to the heat exchanger through the rotameter are not perfectly insulated even though they are covered by aluminium foils. so this can lead to unwanted heat losses. 2. The rotameter setup is actually of metal, so heat loss is possible from the outer surface of the rotameter setup 3. The least count of flow rate reading in the rotameter is very high, which made it difficult to achieve an accurate flow rate reading, leading to some discrepancy in the calculations 4. The temperature sensors might not have been calibrated properly, which may lead to some errors in temperature readings 5. Parallax errors which might arise while noting down the reading 6. Time delay between noting down each temperature readings might lead to some minute change in the temperature, which is not being taken into account Code for the plots
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )