By downloading this file to your compute , you are accepting and agreeing to the terms of AWC’s end-user license agreement (EULA), which may be viewed here: End User License Agreement. Copyright infringement is a violation of federal law subject to criminal and civil penalties. 2021 E D I T I O N SDPWS ® SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC ® AMERICAN WOOD COUNCIL Copyright 2020 APPRO V E© D American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. J U LY 2 2 , 2 0 2 0 AMERICAN WOOD COUNCIL ii SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Updates and Errata While every precaution has been taken to ensure the accuracy of this document, errors may have occured during its development. Updates or Errata are posted to the American Wood Council website at www.awc.org. Technical inquires may be addressed to info@awc.org. The American Wood Council (AWC) is the voice of North American traditional and engineered wood products. From a renewable resource that absorbs and sequesters carbon, the wood products industry makes products that are essential to everyday life. AWC’s engineers, technologists, scientists, and building code experts develop state-of-the-art engineering data, technology, and standards on structural wood products for use by design professionals, building officials, and wood products manufacturers to assure the safe and efficient design and use of wood structural components Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL iii AMERICAN WOOD COUNCIL SDPWS ® SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC ® with Commentary 2021 EDITION APPROVED J U LY 2 2 , 2 0 2 0 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC iv Special Design Provisions For Wind & Seismic 2021 EDITION Special Design Provisions for Wind and Seismic 2021 Edition First Web Version: November 2020 First Print Version: September 2021 ISBN: 978-1-940383-14-9 Copyright © 2020 by American Wood Council All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including, without limitation, electronic, optical, or mechanical means (by way of example and not limitation, photocopying, or recording by or in an information storage retrieval system) without express written permission of the American Wood Council. For information on permission to copy material, please contact: Copyright Permission American Wood Council 222 Catoctin Circle, SE, Suite 201 Leesburg, VA 20175 info@awc.org Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL v TABLE OF CONTENTS 1. Designer Flowchart..................................1 1.1 Flowchart 2. General Design Requirements...............3 2.1 General 2.2 Terminology 2.3 Notation 3. Members and Connections.....................9 3.1 Framing 3.2 Sheathing 3.3 Connections 3.4 Uplift Force Resisting Systems 4. Lateral Force-Resisting Systems.........15 4.1 General 4.2 Sheathed Wood-Frame Diaphragms 4.3 Sheathed Wood-Frame Shear Walls 4.4 Wood Structural Panels Designed to Resist Combined Shear and Uplift from Wind 4.5 Cross-Laminated Timber (CLT) Diaphragms 4.6 Cross-Laminated Timber (CLT) Shear Walls Appendix A..................................................53 Appendix B....................................................55 References....................................................61 LIST OF TABLES 3.1.1.1 Wall Stud Repetitive Member Factors.....10 4.2C Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms (Unblocked Wood Structural Panel Diaphragms) ..........................................27 3.2.1A Nominal Uniform Load Capacities (psf) for Wood Structural Panel Wall Sheathing Resisting Out-of-Plane Wind Loads.........11 3.2.1B Nominal Uniform Load Capacities (psf) for Wall Sheathing Resisting Out-of-Plane Wind Loads.............................................12 4.2D Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms (Lumber Diaphragms) ...........................28 3.2.2 Nominal Uniform Load Capacities (psf) for Roof Sheathing Resisting Out-of-Plane Wind Loads.............................................13 4.3.3 Maximum Shear Wall Aspect Ratios......31 4.3.5.3 Unblocked Shear Wall Adjustment Factor, C(ub).........................................................32 4.2.2. Maximum Diaphragm Aspect Ratios (Flat or Sloped Diaphragms) ..........................18 4.3.5.6 Shear Capacity Adjustment Factor, Co...34 4.2.3 Diaphragm Deflection Equations...........19 4.3A 4.2A Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms (Blocked Wood Structural Panel Diaphragms).............................................25 Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls (Wood-based Panels) .............................40 4.3B 4.2B Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms (Blocked Wood Structural Panel Diaphragms Utilizing Multiple Rows of Fasteners-High Load Diaphragms).......26 Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls (Wood Structural Panels Applied over 1/2" or 5/8"Gypsum Wallboard or Gypsum Sheathing Board)....................................41 4.3C Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls (Gypsum and Portland Cement Plaster)....................................................42 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC WITH COMMENTARY vi 4.3D Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls (Lumber Shear Walls).............................43 4.4.1 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Both Shear Walls and Wind Uplift Simultaneously over Framing with a Specific Gravity of 0.42 or Greater....................................................48 4.4.1.6 4.4.2 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Wind Uplift Only over Framing with a Specific Gravity of 0.42 or Greater.....................................................49 A1 Standard, Common, Box, and Sinker Nails........................................................54 A2 Standard Cut Washers............................54 4F Typical Shear Wall Height-to-Width Ratio for Perforated Shear Walls..........................31 4G Panel Attachment..........................................45 4H Panel Splice Occurring over Horizontal Framing Member..........................................46 4I Panel Splice Occurring across Studs............46 4J Sheathing Splice Plate (Alternate Detail).....47 Maximum Anchor Bolt Spacing (inches) for Combined Shear and Wind Uplift......................................................48 LIST OF FIGURES 4A Examples of Open Front Structures............20 4B Adjoining Panel Edge Locations.............22 4C High Load Diaphragm...................................24 4D Typical Individual Full-Height Wall Segments Height-to-Width Ratio...................................29 4E Typical Shear Wall Height-to-Width Ratio for Shear Walls Designed for Force Transfer Around Openings (FTO)..............................30 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 1 DESIGNER FLOWCHART 1.1 Flowchart 1 2 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 2 1.1 Flowchart DESIGNER FLOWCHART 3 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC GENERAL DESIGNER DESIGN FLOWCHART REQUIREMENTS 2.1 1.1 General Flowchart 2.2 Terminology 2.3 Notation 1 2 42 4 6-7 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 GENERAL DESIGN REQUIREMENTS 2.1 General 2.1.1 Scope The provisions of this document cover materials, design and construction of wood members, fasteners, and assemblies to resist wind and seismic forces. 2.1.2 Design Methods Engineered design of wood structures to resist wind and seismic forces shall be by one of the methods described in 2.1.2.1 and 2.1.2.2. For buildings in Seismic Design Category A, seismic design of the lateral forceresisting systems need only comply with the General Structural Integrity provisions of ASCE 7. Exception: Wood structures shall be permitted to be constructed in accordance with prescriptive provisions permitted by the authority having jurisdiction. 2.1.2.1 Allowable Stress Design: Allowable stress design (ASD) of wood structures shall be in accordance with the National Design Specification® (NDS®) for Wood Construction (ANSI/AWC NDS) and provisions of this document. 2.1.2.2 Strength Design: Load and resistance factor design (LRFD) of wood structures shall be in accordance with the National Design Specification (NDS) for Wood Construction (ANSI/AWC NDS) and provisions of this document. 2.1.3 Sizes Wood product sizes are stated in terms of stand-ard nominal, standard net, or special sizes. For wood structural panels produced in accordance with PS 1 or PS 2, use of the term “nominal panel thickness” in this standard refers to the “Performance Category” value for these products. 2.1.4 Use of Standard 2.1.4.1 Table Footnotes: In this standard, table footnotes shall be considered part of the table. 2.2 Terminology ALLOWABLE STRESS DESIGN. A method of proportioning structural members and their connections such that stresses do not exceed specified allowable stresses when the structure is subjected to appropriate load combinations (also called working stress design). APPROVED. Acceptable to the authority having jurisdiction. ASD REDUCTION FACTOR. A factor to reduce nominal strength to an allowable stress design level. BOUNDARY ELEMENT. Diaphragm and shear wall boundary members to which sheathing transfers forces. Boundary elements include chords and collectors at diaphragm and shear wall perimeters, interior openings, discontinuities, and re-entrant corners. CHORD. A boundary element perpendicular to the applied load that resists axial stresses due to the moment induced by the design load. COLLECTOR. A diaphragm or shear wall boundary element parallel to the applied load that collects and transfers diaphragm shear forces to the vertical force-resisting elements or distributes forces within the diaphragm or shear wall. COMPOSITE PANELS. A wood structural panel comprised of wood veneer and reconstituted wood-based material bonded together with a waterproof adhesive. CROSS LAMINATED TIMBER SHEAR WALL. A shear wall employing cross laminated timber panels and meeting the requirements of Appendix B. CROSS LAMINATED TIMBER SHEAR WALL WITH SHEAR RESISTANCE PROVIDED BY HIGH ASPECT RATIO PANELS ONLY. A cross laminated timber shear wall employing CLT panels of high aspect ratio in accordance with requirements of B.3.7. DIAPHRAGM. A roof, floor, or other membrane bracing system acting to transmit lateral forces to the vertical resisting elements. When the term “diaphragm” is used, it includes horizontal bracing systems. DIAPHRAGM, BLOCKED. A diaphragm in which all adjacent panel edges are fastened to either common framing members or common blocking. DIAPHRAGM BOUNDARY. A location where shear is transferred into or out of the diaphragm sheathing. Transfer is either to a boundary element or to another forceresisting element. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC with synthetic resin or other suitable bonding system by a process in which the interparticle bond is created by the bonding system under heat and pressure. PERFORATED SHEAR WALL. A shear wall with openings in the wall that has not been specifically designed and detailed for force transfer around wall openings, and meets the requirements of 4.3.2.3. PERFORATED SHEAR WALL SEGMENT. A section of a perforated shear wall with full height sheathing that meets the requirements for maximum aspect ratio limits in 4.3.3. PLATFORM CONSTRUCTION. A method of construction by which roof and floor framing bear on load bearing walls that are not continuous through the story levels or floor framing. PLYWOOD. A wood structural panel comprised of plies of wood veneer arranged in cross-aligned layers. The plies are bonded with an adhesive that cures on application of heat and pressure. RESISTANCE FACTOR. A factor that accounts for deviations of the actual strength from the nominal strength and the manner and consequences of failure. SEISMIC DESIGN CATEGORY. A classification assigned to a structure based on its Seismic Use Group (see building code) and the severity of the design earthquake ground motion at the site. SEISMIC FORCE-RESISTING SYSTEM (SFRS). That part of the structural system that has been considered in the design to provide the required resistance to the seismic forces. SHEAR WALL. A wall designed to resist lateral forces parallel to the plane of a wall. SHEAR WALL, BLOCKED. A sheathed wood-frame shear wall in which all adjacent panel edges are fastened to either common framing members or common blocking. SHEAR WALL, UNBLOCKED. A sheathed woodframe shear wall that has fasteners at boundaries and vertical framing members only. Blocking between vertical framing members at adjacent panel edges is not included. SHEAR WALL LINE. A series of shear walls in a line at a given story level. SHEAR WALL SHEATHING SYSTEM. A prescribed combination of sheathing type and fastener type for attachment to wood framing (See also Section 4.3.7). SUBDIAPHRAGM. A portion of a diaphragm used to transfer wall anchorage forces to diaphragm cross ties. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 2 GENERAL DESIGN REQUIREMENTS DIAPHRAGM, UNBLOCKED. A diaphragm that has fasteners at boundaries and supporting members only. Blocking between supporting structural members at panel edges is not included. FIBERBOARD. A fibrous, homogeneous panel made from lignocellulosic fibers (usually wood or cane) and having a density of less than 31 pounds per cubic foot but more than 10 pounds per cubic foot. FORCE-TRANSFER AROUND OPENINGS (FTAO) SHEAR WALL. A shear wall with openings in the wall that have been specifically designed and detailed for force transfer around the openings. GYPSUM BOARD. Generic name for a family of sheet products consisting of a noncombustible core primarily of gypsum with paper surfacing. In this standard, gypsum board includes gypsum wallboard, gypsum base for veneer plaster, water-resistant gypsum backing board, and gypsum sheathing board. HARDBOARD. A fibrous-felted, homogeneous panel made from lignocellulosic fibers consolidated under heat and pressure in a hot press to a density not less than 31 pounds per cubic foot. LATERAL STIFFNESS. The inverse of the deformation of shear walls under an applied unit load, or the force required to deform a shear wall a unit distance. LATERAL FORCE-RESISTING SYSTEM (LFRS). That part of the structural system that has been considered in the design to provide the required resistance to the lateral forces. LOAD AND RESISTANCE FACTOR DESIGN (LRFD). A method of proportioning structural members and their connections using load and resistance factors such that no applicable limit state is reached when the structure is subjected to appropriate load combinations. NOMINAL STRENGTH. Strength of a member, cross section, or connection before application of any strength reduction factors. OPEN FRONT STRUCTURE. A structure in which any diaphragm edge cantilevers beyond vertical elements of the lateral force-resisting system. ORIENTED STRAND BOARD. A mat-formed wood structural panel product composed of thin rectangular wood strands or wafers arranged in oriented layers and bonded with waterproof adhesive. PARTICLEBOARD. A generic term for a panel primarily composed of cellulosic materials (usually wood), generally in the form of discrete pieces or particles, as distinguished from fibers. The cellulosic material is combined 5 6 GENERAL DESIGN REQUIREMENTS TIE-DOWN (HOLD-DOWN). A device used to resist uplift of the chords of shear walls. WALL PIER. A section of wall adjacent to an opening and equal in height to the opening, which is designed to resist lateral forces in the plane of the FTAO shear wall according to the force-transfer method (4.3.2.2). WOOD STRUCTURAL PANEL. A panel manufactured from veneers; or wood strands or wafers; or a combination of veneer and wood strands or wafers; bonded together with waterproof synthetic resins or other suitable bonding systems. Examples of wood structural panels are plywood, oriented strand board (OSB), or composite panels. 2.3 Notation Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 7 2 GENERAL DESIGN REQUIREMENTS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 8 SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC WITH COMMENTARY This page is intentionally left blank. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN GENERAL PROVISIONS DESIGN REQUIREMENTS FOR WIND AND SEISMIC 9 MEMBERS AND CONNECTIONS 3.1 3.2 3.3 3.4 Framing Sheathing Connections Uplift Force Resisting Systems 3 10 10 13 14 Table 3.1.1.1 Wall Stud Repetitive Member Factors..............................10 Table 3.2.1A Nominal Uniform Load Capacities (psf) for Wood Structural Panel Wall Sheathing Resisting Out-of-Plane Wind Loads.................................11 Table 3.2.1B Nominal Uniform Load Capacities (psf) for Wall Sheathing Resiting Out-of-Plane Wind Loads........................................................................12 Table 3.2.2 Nominal Uniform Load Capacities (psf) for Roof Sheathing Resisting Out-of-Plane Wind Loads..................................................................................13 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 10 MEMBERS AND CONNECTIONS 3.1 Framing 3.1.1 Wall Framing In addition to gravity loads, wall framing shall be designed to resist forces induced by the wind and seismic design loads. The framing shall be designed using the methods referenced in 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for strength design (LRFD). 3.1.1.1 Wall Stud Bending Strength and Stiffness Design Value Increase: The reference bending design value, Fb, for sawn lumber wood studs resisting out-ofplane wind loads shall be permitted to be multiplied by the repetitive member factors in Table 3.1.1.1, in lieu of the NDS repetitive member factor, Cr=1.15. The bending stiffness, EI, for sawn lumber studs shall be permitted to be multiplied by the repetitive member factors in Table 3.1.1.1 for the purposes of calculating out-of-plane deflection under wind load. The repetitive member factors in Table 3.1.1.1 apply when studs are designed for bending strength and stiffness, spaced no more than 24"on center, covered on the inside with a minimum of 1/2"gypsum wallboard, attached in accordance with minimum building code requirements and sheathed on the exterior with a minimum of 3/8" (nominal) wood structural panel sheathing with all adjoining panel edges occurring over and fastened to studs or blocking using a minimum of 8d common nails spaced a maximum of 6" on center at panel edges and 12" on center at intermediate framing members. 3.1.2 Floor Framing In addition to gravity loads, floor framing shall be designed to resist forces induced by wind and seismic design loads. The framing shall be designed using the methods referenced in 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for strength design (LRFD). 3.1.3 Roof Framing In addition to gravity loads, roof framing shall be designed to resist forces induced by wind and seismic design loads. The framing shall be designed using the methods referenced in 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for strength design (LRFD). 3.2 Sheathing 3.2.1 Wall Sheathing Exterior wall sheathing and its fasteners shall be capable of resisting wind loads and transferring those loads to the wall framing. Maximum spans and nominal uniform load capacities for wall sheathing materials are given in Tables 3.2.1A and 3.2.1B. The ASD allowable uniform load capacities to be used for wind design shall be determined by dividing the nominal uniform load capacities in Tables 3.2.1A and 3.2.1B by an ASD reduction factor of 1.6. The LRFD factored uniform load capacities to be used for wind design shall be determined by multiplying the nominal uniform load capacities in Tables 3.2.1A and 3.2.1B by a resistance factor, ϕb, of 0.85. No increases shall be permitted. Sheathing used in shear wall assemblies to resist in-plane lateral forces shall be designed in accordance with 4.3. Wood structural panel sheathing or siding used in wall assemblies to resist uplift from wind, or combined shear and uplift from wind shall be designed in accordance with 4.4. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC WITH COMMENTARY 11 Table 3.2.1A Nominal Uniform Load Capacities (psf) for Wood Structural Panel Wall Sheathing Resisting Out-of-Plane Wind Loads 1,2,3 3 MEMBERS AND CONNECTIONS 1. Nominal capacities shall be adjusted in accordance with Section 3.2.1 to determine ASD uniform load capacity and LRFD uniform resistances. 2. Wood structural panels shall conform to the requirements in DOC PS 1 or PS 2. 3. Tabulated capacities are for maximum bending loads from wind. Loads are limited by bending or shear stress assuming a 2-span continuous condition. 4. Strength axis is defined as the axis parallel to the face and back orientation of the flakes or the grain (veneer), which is generally the long panel direction, unless otherwise marked. 5. Plywood load capacities are based on the minimum number of plies permitted for each panel grade in DOC PS 1. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 12 MEMBERS AND CONNECTIONS Table 3.2.1B Nominal Uniform Load Capacities (psf) for Wall Sheathing Resisting Out-of-Plane Wind Loads 1,2,3 1. Nominal capacities shall be adjusted in accordance with Section 3.2.1 to determine ASD uniform load capacity and LRFD uniform resistances. 2. Particleboard sheathing shall conform to ANSI A208.1. Hardboard panel and siding shall conform to the requirements of ANSI/CPA A135.6. Cellulosic fiberboard sheathing shall conform to ASTM C 208. 3. Tabulated capacities are for maximum bending loads from wind. Loads are limited by bending or shear stress assuming a 2-span continuous condition. 4. All edges shall be supported. 3.2.2 Floor Sheathing Floor sheathing shall be capable of resisting and transferring gravity loads to the floor framing. Sheathing used in diaphragm assemblies to resist lateral forces shall be designed in accordance with 4.2. 3.2.3 Roof Sheathing Roof sheathing and its fasteners shall be capable of resisting and transferring wind and gravity loads to the roof framing. Maximum spans and nominal uniform load capacities for roof sheathing materials are given in Table 3.2.2. The ASD allowable uniform load capacities to be used for wind design shall be determined by dividing the nominal uniform load capacities in Table 3.2.2 by an ASD reduction factor of 1.6. The LRFD factored uniform load capacities to be used for wind design shall be determined by multiplying the nominal uniform load capacities in Table 3.2.2 by a resistance factor, ϕb, of 0.85. Sheathing used in diaphragm assemblies to resist lateral forces shall be designed in accordance with 4.2. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC WITH COMMENTARY 13 Table 3.2.2 Nominal Uniform Load Capacities (psf) for Roof Sheathing Resisting Out-of-Plane Wind Loads 1,2,3 3 MEMBERS AND CONNECTIONS 1. Nominal capacities shall be adjusted in accordance with Section 3.2.3 to determine ASD uniform load capacity and LRFD uniform resistances. 2. Wood structural panels shall conform to the requirements in DOC PS 1 or PS 2. 3. Tabulated capacities are for maximum bending loads from wind. Loads are limited by bending or shear stress assuming a 2-span continuous condition. 4. Strength axis is defined as the axis parallel to the face and back orientation of the flakes or the grain (veneer), which is generally the long panel direction, unless otherwise marked. 5. Plywood load capacities are based on the minimum number of plies permitted for each panel grade in DOC PS 1. 6. Blocking required at panel ends. 3.3 Connections Connections resisting forces induced by wind and seismic design loads shall be designed in accordance with the methods referenced in 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for strength design (LRFD). Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL MEMBERS AND CONNECTIONS 14 3.4 Uplift Force Resisting Systems 3.4.1. General The proportioning, design, and detailing of engineered wood systems, members, and connections resisting wind uplift shall be in accordance with the reference documents in 2.1.2 and the provisions of 3.4.2. A continuous load path, or paths, with adequate strength and stiffness shall be provided to transfer all forces from the point of application to the final point of resistance. 3.4.2 Design Requirements Uplift force resisting systems shall comply with the following: 1. Metal connectors, continuous tie rods, or other similar connection devices used in the wind uplift load path shall be of adequate strength and stiffness to transfer forces induced by design loads to supporting elements. 2. The strength and stiffness of wood members and connections used in combination with metal connectors, continuous tie rods, or other similar connection devices shall be determined in accordance with 2.1.2. 3. Where wind uplift load path connections are not aligned from point of load application to point of resistance, additional forces and deflections resulting from such eccentricities shall be accounted for in the design of supporting load path elements. Exception: Walls sheathed with wood structural panel sheathing or siding that are designed to resist uplift from wind, or combined shear and uplift from wind shall be in accordance with 4.4. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 15 LATERAL FORCERESISTING SYSTEMS 4 4.1 General 16 4.2 Sheathed Wood-Frame Diaphragms 18 4.3 Sheathed Wood-Frame Shear Walls 29 4.4 Wood Structural Panels Used in Walls Designed to Resist Combined Shear and Uplift from Wind 44 4.5 Cross-Laminated Timber (CLT) Diaphragms 50 4.6 Cross-Laminated Timber (CLT) Shear Walls 51 Table 4.2.2 Maximum Diaphragm Aspect Ratios .................................................... 18 Table 4.2.3 Diaphragm Deflection Equations.........................................................19 Tables 4.2A-D Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms..........................................................................................25-28 Table 4.3.3 Maximum Shear Wall Aspect Ratios.................................................31 Table 4.3.5.3 Unblocked Shear Wall Adjustment Factor, C(ub)...................................32 Table 4.3.5.6 Shear Capacity Adjustment Factor, Co..........................................34 Tables 4.3A-D Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls.....................................................................................................40-43 Table 4.4.1 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Both Shear Walls and Wind Uplift Simultaneously..........................................................................................48 Table 4.4.1.6 Maximum Anchor Bolt Spacing (inches) for Combined Shear and Uplift..........................................................................................................48 Table 4.4.2 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Wind Uplift Only...............................................49 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 16 4.1 General 4.1.1 Design Requirements The proportioning, design, and detailing of engineered wood systems, members, and connections in lateral force-resisting systems shall be in accordance with the reference documents in 2.1.2 and provisions in this chapter. A continuous load path, or paths, with adequate strength and stiffness shall be provided to transfer all forces from the point of application to the final point of resistance. Structures resisting wind and seismic loads shall meet all applicable drift, deflection, and deformation requirements of this standard and the applicable building code or, in the absence of an applicable building code, ASCE 7. Shear capacity shall be determined in accordance with 4.1.4.1 for seismic design and in accordance with 4.1.4.2 for wind design. 4.1.2 Wood Lateral Force Resisting Systems 4.1.2.1 Sheathed Wood-frame Diaphragms and Shear Walls: Design of sheathed wood-frame diaphragms and shear walls shall be in accordance with 4.2 and 4.3, respectively. Wood structural panels designed to resist combined shear and uplift shall be in accordance with 4.4. The tabulated nominal unit shear capacities are based on the sheathing and fasteners stated in each table attached to Douglas-Fir-Larch or Southern Pine framing, with adjustments for other framing species. For sheathing or fasteners not specifically stated in the tables, or for framing other than sawn lumber or structural glued-laminated timber, refer to the manufacturer’s approved instructions or approved evaluation report. Shear capacity of sheathed wood-frame diaphragms and sheathed woodframe shear walls shall be permitted to be calculated using approved alternate procedures that are in accordance with principles of engineering mechanics using values of fastener strength and sheathing shear capacity. 4.1.2.2 Cross-Laminated Timber (CLT) Diaphragms and Shear Walls: Design of CLT diaphragms and shear walls shall be in accordance with 4.5 and 4.6, respectively. CLT diaphragms and CLT shear walls shall be permitted to be designed using approved alternate procedures that are in accordance with principles of engineering mechanics. structural elements shall be considered in design such that the deformation of each element and connection comprising the lateral force-resisting system is compatible with the deformations of the other lateral force-resisting elements and connections and with the overall system. 4.1.4 Shear Capacities 4.1.4.1 For seismic design of diaphragms and shear walls, the ASD allowable shear capacity shall be determined by dividing the nominal shear capacity in 4.1.2 by the ASD reduction factor of 2.8 and the LRFD factored shear resistance shall be determined by multiplying the nominal shear capacity by a resistance factor, ϕD, of 0.50. No further increases shall be permitted. 4.1.4.2 For wind design of diaphragms and shear walls, the ASD allowable shear capacity shall be determined by dividing the nominal shear capacity in 4.1.2 by the ASD reduction factor of 2.0 and the LRFD factored shear resistance shall be determined by multiplying the nominal shear capacity by a resistance factor, ϕD, of 0.80. No further increases shall be permitted. 4.1.5 Wood Members and Systems Resisting Seismic Forces Contributed by Concrete and Masonry Walls Wood-frame shear walls, wood-frame diaphragms, trusses, and other wood members and systems shall not be used to resist seismic forces contributed by concrete or masonry walls in structures over one story in height. Exceptions: 1. Wood floor and roof members shall be permitted to be used in diaphragms and horizontal trusses to resist horizontal seismic forces contributed by masonry or concrete walls provided such forces do not result in torsional force distribution through the diaphragm or truss. 2. Vertical wood structural panel sheathed shear walls shall be permitted to be used to provide resistance to seismic forces contributed by concrete or masonry walls in two-story structures, provided the following requirements are met: a. Story-to-story wall heights shall not exceed 12 ̍. 4.1.3 Deformation Requirements Deformation of connections within and between b. Diaphragms shall not be considered to trans- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC mit lateral forces by torsional force distribution or cantilever past the outermost supporting shear wall. c. Combined deflections of diaphragms and shear walls shall not permit design story drift of supported concrete or masonry walls to exceed the allowable story drift in accordance with Section 12.12.1 of ASCE 7. d. Wood structural panel diaphragms shall be blocked diaphragms. f. There shall be no out-of-plane horizontal offsets between the first and second stories of wood structural panel shear walls. 4.1.5.1 Anchorage of Concrete or Masonry Structural Walls to Diaphragms: In Seismic Design Categories C, D, E, or F, diaphragms shall be provided with continuous ties or struts between diaphragm chords to distribute concrete or masonry structural wall anchorage forces in accordance with Section 12.11.2 of ASCE 7 into the diaphragms. Subdiaphragms shall be permitted to be used to transmit the anchorage forces to the main continuous cross-ties. The maximum length-to-width ratio of the structural subdiaphragm shall be 2.5:1. Connections and anchorages capable of resisting the prescribed forces shall be provided between the diaphragm and the attached components. 4.1.5.1.1 Anchorage shall not be accomplished by use of nails subject to withdrawal or toe-nails nor shall wood ledgers or framing be used in cross-grain bending or cross-grain tension. 4.1.5.1.2 The diaphragm sheathing shall not be considered effective as providing the ties or struts required by this section. 4.1.6 Wood Members and Systems Resisting Seismic Forces from Other Concrete or Masonry Construction 4.1.7 Horizontal Distribution of Shear The distribution of shear to vertical resisting elements shall be based on an analysis where the diaphragm is idealized as flexible, idealized as rigid, or modeled as semi-rigid. 4.1.7.1 Flexible Diaphragm. When a diaphragm is idealized as flexible in accordance with ASCE 7, the diaphragm shear forces shall be distributed to the vertical elements of the lateral force-resisting system (LFRS) of the story below based on tributary area. 4.1.7.2 Rigid Diaphragm. When a diaphragm is idealized as rigid, the diaphragm shear forces shall be distributed based on the relative lateral stiffnesses of the vertical elements of the LFRS of the story below. A diaphragm shall be permitted to be idealized as rigid when the calculated maximum in-plane deflection of the diaphragm itself under lateral load is less than or equal to two times the average deflection of adjoining vertical elements of the associated LFRS of the story below. A cantilevered diaphragm shall be permitted to be idealized as rigid when the calculated maximum in-plane deflection of the diaphragm itself under lateral load is less than or equal to two times the deflection of adjoining vertical elements of the associated LFRS of the story below used to determine the cantilever length, L' (See Figure 4A). The calculated deflections required by this section, for diaphragm and adjoining vertical elements of the associated LFRS, shall be determined using an equivalent tributary lateral load. 4.1.7.3 Semi-Rigid Diaphragm. When a diaphragm is not idealized as rigid or flexible, the diaphragm shear forces shall be distributed to the vertical resisting elements using a semi-rigid diaphragm analysis based on the relative stiffnesses of the diaphragm and the vertical resisting elements accounting for both shear and flexural deformations. In lieu of using a semi-rigid diaphragm analysis for distribution of story shear forces, it shall be permitted to use an enveloped analysis whereby distribution of horizontal diaphragm shear to each vertical resisting element is the larger of the shear forces resulting from analyses where the diaphragm is idealized as flexible and the diaphragm is idealized as rigid. 4.1.8 Vertical Distribution of Seismic ForceResisting System (SFRS) Strength Wood members and systems shall be permitted to be used where designed to resist seismic forces from concrete, or masonry components other than walls, including but not limited to: chimneys, fireplaces, concrete or masonry veneers, and concrete floors. For structures assigned to Seismic Design Category D, E, or F, the lateral design strength of the vertical elements of the SFRS for the story under evaluation, Vr(i), shall not be less than the lateral design strength of the vertical elements of the SFRS for the story above, Vr(i+1). Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS e. Wood structural panel shear walls shall be blocked shear walls and, for the lower story, the sheathing shall have a minimum nominal panel thickness of 15/32". 17 18 LATERAL FORCE-RESISTING SYSTEMS EXCEPTION: Vr(i) shall be permitted to be less than Vr(i+1), where the ratio of the shear force induced by the design load for the story under evaluation, V(i), divided by Vr(i) is less than Vr(i) / Vr(i+1): strated that the moments, shears, and deflections, considering eccentricities resulting from other configurations, can be tolerated without exceeding the framing capacity and drift limits. 4.1.10 Toe-Nailed Connections 4.1.9 Boundary Elements Shear wall and diaphragm boundary elements shall be provided to transfer the design tension and compression forces. Diaphragm and shear wall sheathing shall not be used to splice boundary elements. Diaphragm chords and collectors shall be placed in, or in contact with, the plane of the diaphragm framing unless it can be demon- In seismic design categories D, E, and F, the capacity of toe-nailed connections shall not be used when calculating lateral load resistance to transfer seismic lateral forces greter than 150 pounds per lineal foot for ASD and 205 pounds per lineal foot for LRFD from diaphragms to shear walls, collectors, or other elements, or from shear walls to other elements. 4.2 Sheathed Wood-Frame Diaphragms 4.2.1 Application Requirements Sheathed wood-frame diaphragms shall be permitted to be used to resist lateral forces provided the deflection in the plane of the diaphragm, as determined by calculations, tests, or analogies drawn therefrom, does not exceed the maximum permissible deflection limit of attached load distributing or resisting elements. Permissible deflection shall be that deflection that will permit the diaphragm and any attached elements to maintain their structural integrity and continue to support their prescribed loads as determined by the applicable building code or standard. Framing members, blocking, and connections shall extend into the diaphragm a sufficient distance to develop the force transferred into the diaphragm. 4.2.2 Diaphragm Aspect Ratios Size and shape of diaphragms shall be limited to the aspect ratios in Table 4.2.2. 4.2.3 Deflection Calculations of diaphragm deflection shall account for bending and shear deflections, fastener deformation, chord splice slip, and other contributing sources of deflection. The diaphragm deflection, δdia, shall be permitted to be calculated by use of the equations in Table 4.2.3. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table 4.2.3 Diaphragm Deflection Equations 19 Deflection of wood structural panel diaphragms shall be permitted to be calculated using approved alternate procedures that follow a rational analysis where apparent shear stiffness accounts for panel shear deformation and non-linear nail slip in the sheathing-to-framing connection. 4.2.4 Shear Capacities 4.2.5 Torsional Requirements 4.2.5.1 Torsional Irregularity: Structures with sheathed wood-frame diaphragms modeled as semi-rigid or idealized as rigid shall be considered as torsionally irregular under seismic load when the maximum story drift, computed from seismic design forces including accidental torsion, at one end of the structure is more than 1.2 times the average of the story drifts at the two ends of the structure. Where a torsional irregularity exists in structures assigned to Seismic Design Category B, C, D, E or F, sheathed wood-frame diaphragms shall meet all of the following requirements: 1. The diaphragm shall conform to 4.2.8.1, 4.2.8.2, or 4.2.8.3. 2. The L/W ratio shall not be greater than 1.5:1 when sheathed in conformance with 4.2.8.1 or not greater than 1:1 when sheathed in conformance with 4.2.8.2 or 4.2.8.3. 3. The maximum story drift at each edge of the structure shall not exceed the ASCE 7 allowable story drift when subject to seismic design forces including torsion and accidental torsion. 4.2.6 Open Front Structures (Cantilevered Diaphragms) 4.2.6.1 For resistance to seismic loads, sheathed wood-frame diaphragms in open front structures shall comply with all of the following requirements: 1. The diaphragm shall conform to 4.2.8.1, 4.2.8.2, or 4.2.8.3. 2. The L′/W′ ratio (as shown in Figure 4A (a through d)) shall not be greater than 1.5:1 when Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 4.2.4.1 ASD allowable shear capacity or LRFD factored shear resistance for sheathed wood-frame diaphragms shall be determined in accordance with 4.1.4. 4.2.4.2 Nominal unit shear capacities are provided in Tables 4.2A, 4.2B, 4.2C, and 4.2D. 4 20 LATERAL FORCE-RESISTING SYSTEMS sheathed in conformance with 4.2.8.1 or not greater than 1:1 when sheathed in conformance with 4.2.8.2 or 4.2.8.3. For open front structures that are also torsionally irregular as defined in 4.2.5.1, the L′/W′ ratio shall not exceed 0.67:1 for structures over one story in height, and 1:1 for structures one story in height. 3. For loading parallel to the open side, diaphragms shall be modeled as semi-rigid or idealized as rigid, and the maximum story drift at each edge of the structure shall not exceed the ASCE 7 allowable story drift when subject to seismic design forces including torsion and accidental torsion and shall include shear and bending deformations of the diaphragm. 4. The cantilevered diaphragm length, L′, (normal to the open side) shall not exceed 35 feet. Exception: Sheathed wood-frame diaphragms in open front structures in which the diaphragm edge cantilevers no more than six feet beyond the nearest line of vertical elements of the lateral force-resisting system need not comply with Section 4.2.6.1. 4.2.6.2 For open front structures one story in height, where L′ is not more than 25′ and L′/W′ is less than or equal to 1:1, the cantilevered diaphragm defined by L′ x W′ (as shown in Figure 4A) shall be permitted to be idealized as rigid for purposes of distribution of shear forces through torsion. Figure 4A Examples of Open Front Structures 4.2.7 Construction Requirements 4.2.7.1 Framing Requirements: Diaphragm boundary elements shall be provided to transmit the design tension, compression, and shear forces. Diaphragm sheathing shall not be used to splice boundary elements. Diaphragm chords and collectors shall be placed in, or in contact with, the plane of the diaphragm framing unless it can be demonstrated that the moments, shears, and deflections, considering eccentricities resulting from other configurations, can be tolerated without exceeding the framing capacity and drift limits. 4.2.7.2 Sheathing: Diaphragms shall be sheathed with approved materials. Details on sheathing types and thicknesses for commonly used floor, roof, and ceiling diaphragm assemblies are provided in 4.2.8 and Tables 4.2A, 4.2B, 4.2C, and 4.2D. 4.2.7.3 Fasteners: Sheathing shall be attached to framing members using nails or other approved fasteners alone, or in combination with adhesives. Nails shall be driven with the head of the nail flush with the surface of the sheathing. Other approved fasteners shall be driven as required for proper installation of that fastener. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 4.2.8 Sheathed Wood-Frame Diaphragm Assemblies 3. The width of the nailed face of framing members and blocking shall be 2" nominal or greater. Additionally, the width of the nailed face of framing members and blocking shall be 3" nominal or greater and nails shall be staggered at the following adjoining panel edge locations: a. Where a nail spacing of 2-1/2" on center or less is specified in Table 4.2A. b. Where 10d common nails with a nail spacing of 3" on center are specified in Table 4.2A. Exception: Where 10d common nails with a spacing of 3" on center are specified in Table 4.2A at adjoining panel edges that are not continuous (see Figure 4B), the width of the nailed face of framing members and blocking shall be permitted to be 2" nominal provided that the nominal unit shear capacities from Table 4.2A are limited to values tabulated for the 2" minimum nominal width of nailed face, regardless of whether 3" nominal or greater width framing members or blocking are used at diaphragm boundaries and continuous adjoining panel edges. 1. Panel edges shall not coincide with joints in the lumber planking or laminated decking 2. Adjacent panel edges parallel to the planks or decking shall be fastened to a common member. 3. The planking or decking shall be of sufficient thickness to satisfy minimum nail bearing length in framing members and blocking as required in Table 4.2A. 5. Diaphragm forces shall be transferred from wood structural panel sheathing to diaphragm boundary elements through planking or decking or by other methods. 4. At diaphragm boundaries where a nail spacing of 2-1/2" on center or less is specified, nails shall be staggered. 5. Wood structural panels shall conform to the requirements for their type in DOC PS1or PS2. 4.2.8.1.1 Blocked Diaphragms: Where diaphragms are designed as blocked, all adjoining panel edges shall occur over and be fastened to common framing members or common blocking. The size and spacing of nails at wood-frame diaphragm boundaries and panel edges shall be as prescribed in Table 4.2A. The diaphragm shall be constructed as follows: 1. Panels shall not be less than 4' x 8' except at boundaries and changes in framing. 2. Nails shall be located at least 3/8" from the edges of panels. Maximum nail spacing at panel edges shall be 6" on center. Nails along intermediate framing members and blocking for panels shall be the same size as installed at the panel edges. Maximum nail spacing shall be 6" on center when support spacing of 48" on center is specified and 12" on center for closer support spacings. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS 4.2.8.1 Wood Structural Panel Diaphragms: Diaphragms sheathed with wood structural panel sheathing shall be permitted to be used to resist seismic and wind forces. Wood structural panel sheathing used for diaphragms that are part of the lateral force-resisting system shall be applied directly to the framing members and blocking. Exception: Wood structural panel sheathing in a diaphragm is permitted to be fastened over solid lumber planking or laminated decking provided the following requirements are met: 4. Diaphragm aspect ratio (L/W) shall not exceed that for a blocked wood structural panel diaphragm (4:1). 21 22 LATERAL FORCE-RESISTING SYSTEMS Figure 4B Adjoining Panel Edge Locations 4.2.8.1.2 High Load Blocked Diaphragms: All adjoining panel edges shall occur over and be fastened to common framing members or common blocking. The size and spacing of nails at wood-frame diaphragm boundaries and panel edges shall be as prescribed in Table 4.2B and Figure 4C. The diaphragms shall be constructed as follows: 1. Panels shall not be less than 4' x 8' except at boundaries and changes in framing. 2. Nails shall be located at least 3/8" from panel edges but not less than distances shown in Figure 4C. Maximum nail spacing at panel edges shall be 6" on center. Nails along intermediate framing members for panels shall be the same size as installed at the panel edges. Maximum nail spacing shall be 6" on center when support spacing of greater than 32" on center is specified. Maximum nail spacing shall be 12" on center for specified support spacing of 32" on center or less. 3. In diaphragm boundary members, lines of nails shall be equally spaced and fasteners within each line shall be staggered where spacing is 3" on center or less. 4. The depth of framing members and blocking into which the nail penetrates shall be 3" nominal or greater. 5. The width of the nailed face of framing members and blocking at boundaries and adjoining panel edges shall be 3" nominal or greater. The width of the nailed face not located at boundaries or adjoining panel edges shall be 2" nominal or greater. 6. Wood structural panels shall conform to the requirements for their type in DOC PS1 or PS2. 4.2.8.1.3 Unblocked Diaphragms: Where diaphragms are designed as unblocked, the diaphragms shall be constructed as specified in 4.2.8.1.1, except that blocking between supporting structural members at panel edges shall not be required. The size and spacing of nails at woodframe diaphragm boundaries and panel edges shall be as prescribed in Table 4.2C. Panels shall not be less than 4' x 8' except at boundaries and changes in framing where minimum panel dimension shall be 24" unless all edges of the undersized panels are supported by and fastened to framing members or blocking. 4.2.8.2 Diaphragms Diagonally-Sheathed with Single-Layer of Lumber: Single-layer diagonally-sheathed Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC each other on the same face of the supporting members. Each chord shall be considered as a beam with uniform load per foot equal to 50% of the unit shear due to diaphragm action. The load shall be assumed as acting normal to the chord in the plane of the diaphragm in either direction. Nailing of double-layer diagonally-sheathed lumber diaphragms shall be in accordance with Table 4.2D. 4.2.8.4 Diaphragms Horizontally-Sheathed with Single-Layer of Lumber: Single-layer horizontally-sheathed lumber diaphragms shall be permitted to be used to resist seismic and wind forces. Single-layer horizontallysheathed lumber diaphragms shall be constructed of minimum 1" thick nominal sheathing boards or minimum 2" thick nominal lumber laid perpendicular to the supports. End joints in adjacent boards shall be separated by at least one joist space and there shall be at least two boards between joints on the same support. Nailing of singlelayer horizontally-sheathed lumber diaphragms shall be in accordance with Table 4.2D. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS lumber diaphragms shall be permitted to be used to resist seismic and wind forces. Single-layer diagonallysheathed lumber diaphragms shall be constructed of minimum 1" thick nominal sheathing boards or 2" thick nominal lumber laid at an angle of approximately 45° to the supports. End joints in adjacent boards shall be separated by at least one joist space and there shall be at least two boards between joints on the same support. Nailing of diagonally-sheathed lumber diaphragms shall be in accordance with Table 4.2D. Single-layer diagonallysheathed lumber diaphragms shall be permitted to consist of 2" nominal lumber (1-½" thick) where the supports are not less than 3" nominal (2-½" thick) in width or 4" nominal (3-½" deep) in depth. 4.2.8.3 Diaphragms Diagonally-Sheathed with Double-Layer of Lumber: Double-layer diagonally- sheathed lumber diaphragms shall be permitted to be used to resist seismic and wind forces. Double-layer diagonallysheathed lumber diaphragms shall be constructed of two layers of diagonal sheathing boards laid perpendicular to 23 24 LATERAL FORCE-RESISTING SYSTEMS Figure 4C High Load Diaphragm Note: Space adjoining panel edges 1/8" apart. Minimum spacing between lines of fasteners is 3/8". Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 25 Table 4.2A Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms 4 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.2.7. For specific requirements, see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. 2. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. 3. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for diaphragms constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2 4. Where moisture content of the framing is greater than 19% at time of fabrication, Ga values shall be multiplied by 0.5. 5. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. 6. Diaphragm resistance depends on the direction of continuous adjoining panel edges with respect to the loading direction and direction of framing members, and is independent of the panel orientation. 26 LATERAL FORCE-RESISTING SYSTEMS Table 4.2B Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.2.7. For specific requirements, see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. 2. For species and grades of framing other than Douglas-Fir Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3.A). The Specific Gravity Adjustment Factor shall not be greater than 1. 3. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for diaphragms constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2. 4. Where moisture content of the framing is greater than 19% at time of fabrication, Ga values shall be multiplied by 0.5. 5. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. 6. Diaphragm resistance depends on the direction of continuous adjoining panel edges with respect to the loading direction and direction of framing members, and is independent of the panel orientation. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 27 Table 4.2C Nominal Unit Shear Values for Sheathed Wood-Frame Diaphragms 4 LATERAL FORCE-RESISTING SYSTEMS 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.2.7. For specific requirements, see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. 2. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. 3. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for diaphragms constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2. 4. Where moisture content of the framing is greater than 19% at time of fabrication, Ga values shall be multiplied by 0.5. 5. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. 6. Diaphragm resistance depends on the direction of continuous adjoining panel edges with respect to the loading direction and direction of framing members, and is independent of the panel orientation. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 28 LATERAL FORCE-RESISTING SYSTEMS Table 4.2D Nominal Unit Shear Capacities for Sheathed Wood-Frame Diaphragms 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.2.7. For specific requirements, see 4.2.8.2 for diaphragms diagonally sheathed with a single-layer of lumber, see 4.2.8.3 for diaphragms diagonally sheathed with a double-layer of lumber, and see 4.2.8.4 for diaphragms horizontally sheathed with a single-layer of lumber. See Appendix A for common and box nail dimensions. 2. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 29 4.3 Sheathed Wood-Frame Shear Walls 4.3.1 Application Requirements 4. Where out-of-plane offsets occur, portions of the wall on each side of the offset shall be considered as separate FTAO shear walls. 5. Collectors for transfer of shear forces between the diaphragms and the shear wall shall not be less than the full length of the FTAO shear wall. Figure 4D Typical Individual Full-Height Wall Segments Height-toWidth Ratio 4.3.2 Shear Wall Types Shear walls shall be designed as one of the three types described in this section. 4.3.2.1 Individual Full-Height Wall Segments: Where individual full-height wall segments are designed as shear walls without openings, the aspect ratio limitations of 4.3.3 shall apply to each full-height wall segment as illustrated in Figure 4D. The following limitations shall apply: 1. Openings shall be permitted to occur beyond the ends of a shear wall. The length of such openings shall not be included in the length of the shear walls. 2. Where out-of-plane offsets occur, portions of the wall on each side of the offset shall be considered as separate shear walls. 3. Collectors for transfer of shear forces between the diaphragms and the individual full-height wall segments shall be provided. 4.3.2.2 Force-Transfer Around Openings (FTAO) Shear Walls: For FTAO shear walls, the aspect ratio limitations of 4.3.3.3 shall apply to each wall pier as illustrated in Figure 4E. Design for force transfer around the openings shall be based on a rational analysis. The following limitations shall apply: 1. Framing members, blocking, and connections around openings shall be designed for force transfer around the openings. 2. The length of each wall pier shall not be less than 2'. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS Sheathed wood-frame shear walls shall be permitted to resist lateral forces provided the deflection of the shear wall, as determined by calculations, tests, or analogies drawn therefrom, does not exceed the maximum permissible deflection limit. Permissible deflection shall be that deflection that permits the shear wall and any attached elements to maintain their structural integrity and continue to support their prescribed loads as determined by the applicable building code or standard. Framing members, blocking, and connections shall extend into the shear wall a sufficient distance to develop the force transferred into the shear wall. 3. A full-height wall segment shall be located at each end of a FTAO shear wall. LATERAL FORCE-RESISTING SYSTEMS 30 Figure 4E Typical Shear Wall Height-toWidth Ratio for Shear Walls Designed for Force Transfer Around Openings (FTAO) 5. Where out-of-plane offsets occur, portions of the wall on each side of the offset shall be considered as separate perforated shear walls. 6. Collectors for transfer of shear forces between the diaphragms and the shear wall shall not be less than the full length of the perforated shear wall. 7. A perforated shear wall shall have uniform topof-wall and bottom-of-wall elevations. Perforated shear walls not having uniform elevations shall be designed by other methods. 8. Perforated shear wall height, h, shall not exceed 20'. 9. All sheathed areas of the perforated shear wall shall be constructed with sheathing and sheathing attachment associated with the tabulated nominal unit shear capacity in 4.3.5.6 for the selected shear wall configuration. Exception: Sheathed areas constructed with sheathing and sheathing attachment associated with a tabulated nominal unit shear capacity less than required in 4.3.2.3(9) are permitted, provided they are included in the total area of openings, Ao. 4.3.2.3 Perforated Shear Walls: Where shear walls with openings are not designed for force transfer around the openings, they shall be designed as perforated shear walls (Figure 4F). Perforated shear walls shall be sheathed on one or both sides with wood structural panel sheathing. The combined nominal unit shear capacity of perforated shear walls sheathed with wood structural panel sheathing on one side and gypsum wallboard on the opposite side shall be permitted to be determined in accordance with Section 4.3.5.4.2. The following limitations shall apply: 1. Framing members, blocking, and connections around openings are not designed for forcetransfer around the openings. 2. A perforated shear wall segment shall be located at each end of a perforated shear wall. 3. The aspect ratio limitations of Section 4.3.3.4 shall apply. 4. The nominal unit shear capacity for single-sided and double-sided walls shall not exceed 2,435 plf. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Figure 4F Typical Shear Wall Height-toWidth Ratio for Perforated Shear Walls 4.3.3.1 The size and shape of shear walls shall be limited to the aspect ratios in Table 4.3.3. 4.3.3.2 For wood structural panel shear walls with aspect ratios (h/b) greater than 2:1, the nominal shear capacity shall be multiplied by the Aspect Ratio Factor (WSP) = 1.25-0.125 h/b. For structural fiberboard shear walls with aspect ratios (h/b) greater than 1:1, the nominal shear capacity shall be multiplied by the Aspect Ratio Factor (fiberboard) = 1.09-0.09 h/b. 4.3.3.3 Aspect Ratio of FTAO Shear Walls: The aspect ratio limitations of Table 4.3.3 shall apply to the overall shear wall including openings and to each wall pier at the sides of openings. The height of a wall pier with an opening on one side shall be defined as the clear height of the pier at the side of the opening. The height of a wall pier with an opening on each side shall be defined as the larger of the clear heights of the pier at the sides of the openings. The length of a wall pier shall be defined as the sheathed length of the pier. Wall piers with aspect ratios exceeding 3.5:1 shall not be considered as portions of FTAO shear walls. Maximum Shear Wall Aspect Ratios 1. Walls having aspect ratios exceeding 1.5:1 shall be blocked shear walls. 2. For wind design of blocked wood structural panel shear walls or structural fiberboard shear walls, with gypsum wallboard on the opposite side, maximum h/b for gypsum wallboard shall be permitted to be 3.5:1. 4.3.4 Deflection Calculations of shear wall deflection shall account for bending and shear deflections, fastener deformation, anchorage slip, and other contributing sources of deflection. 4.3.4.1 Deflection of Individual Full-Height Shear Walls: The shear wall deflection, δsw, shall be permitted to be calculated by use of the following equation: Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS 4.3.3.4 Aspect Ratio of Perforated Shear Wall Segments: The aspect ratio limitations of Table 4.3.3 shall apply to perforated shear wall segments within a perforated shear wall as illustrated in Figure 4E. Portions of walls with aspect ratios exceeding 3.5:1 shall not be considered in the sum of shear wall segments, Σbi. In the design of perforated shear walls, the length of each perforated shear wall segment with an aspect ratio greater than 2:1 shall be multiplied by 2bi/h for the purposes of determining bi and Σbi. The provisions of Section 4.3.3.2 and the exceptions to Section 4.3.5.5.1 shall not apply to perforated shear wall segments. Table 4.3.3 4.3.3 Shear Wall Aspect Ratios and Capacity Adjustments 31 32 LATERAL FORCE-RESISTING SYSTEMS 4.3.5 Shear Capacities 4.3.5.1 ASD allowable shear capacity or LRFD factored shear resistance for sheathed wood-frame shear walls shall be determined in accordance with 4.1.4. 4.3.5.2 Nominal Unit Shear Capacities: Nominal unit shear capacities are provided in Tables 4.3A, 4.3B, 4.3C, and 4.3D. 4.3.5.3 Unblocked Wood Structural Panel Shear Walls: Wood structural panel shear walls shall be permitted to be unblocked provided nails are installed into framing in accordance with Table 4.3.5.3 and the strength is calculated in accordance with Equation 4.3-2. Unblocked shear wall height shall not exceed 16 feet. The nominal unit shear capacity of an unblocked wood structural panel shear wall, νn(ub), shall be calculated using the following equation: Deflection of wood structural panel shear walls shall be permitted to be calculated using approved alternate procedures that follow a rational analysis where apparent shear stiffness accounts for panel shear deformation and non-linear nail slip in the sheathing to framing connection. 4.3.4.2 Deflection of Perforated Shear Walls: The deflection of a perforated shear wall shall be calculated in accordance with 4.3.4, where v in equation 4.3-1 is equal to νmax obtained in equation 4.3-9 and b is taken as Σbi. 4.3.4.3 Deflection of Unblocked Wood Structural Panel Shear Walls: The deflection of an unblocked wood structural panel shear wall shall be permitted to be calculated in accordance with 4.3.4 using a Ga for 24" stud spacing and nails spaced at 6" on center at panel edges and 12" on center at intermediate framing members. The unit shear force induced by the design load, ν, in pounds per foot used in Equation 4.3-1 shall be divided by C(ub), from Table 4.3.5.3. 4.3.4.4 Deflection of Structural Fiberboard Shear Walls: For a structural fiberboard shear wall with an aspect ratio (h/b) greater than 1.0, the deflection obtained from equation 4.3-1 shall be multiplied by (h/b)1/2. Table 4.3.5.3 Unblocked Shear Wall Adjustment Factor, C(ub) 4.3.5.4 Shear Stiffness and Shear Capacity for Shear Walls Sheathed on Opposing Sides of Common Framing: Where shear walls are designed with similar shear wall sheathing systems from 4.3.7 on both sides of common framing, provisions of 4.3.5.4.1 apply. Where shear walls are designed with different shear wall sheathing systems Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC be either two times the apparent shear stiffness of the shear wall sheathing system with the smaller nominal unit shear capacity or the apparent shear stiffness of the shear wall sheathing system with the larger nominal unit shear capacity. Exception: For wind design, the combined nominal unit shear capacity, νn(c), of shear walls sheathed with a combination of wood structural panels, hardboard panel siding, or structural fiberboard on one side and gypsum wallboard on the opposite side shall equal the sum of the sheathing capacities of each side. 4.3.5.5 Shear Walls in a Line: The provisions of this section are limited to shear distribution to individual shear walls in a shear wall line where the individual shear walls have the same sheathing materials. 4.3.5.5.1 Shear distribution to individual shear walls in a shear wall line shall provide the same calculated deflection, δsw, in each shear wall. Exceptions: 1. Shear distribution to wood structural panel individual full-height shear walls in a shear wall line, including shear walls sheathed on opposing sides of common framing and assigned shear capacities in accordance with 4.3.5.4.1, shall be permitted to be taken as proportional to the design shear capacities of the individual full-height shear walls provided that the nominal shear capacities of all full-height shear walls with aspect ratios (h/b) greater than 2:1 are multiplied by 2b/h . Where multiplied by 2b/h, the nominal shear capacities need not be further reduced by the adjustment in 4.3.3.2. 4.3.5.4.2 Shear Walls with Dissimilar Shear Wall Sheathing Systems on Opposing Sides of Common Framing: The combined nominal unit shear capacity, νn(c), shall be taken as either two times the smaller nominal unit shear capacity or as the larger nominal unit shear capacity, whichever is greater. The combined apparent shear wall shear stiffness, Ga(c), shall be associated with the nominal unit shear capacity used in design and shall 2. Shear distribution to structural fiberboard individual full-height shear walls in a shear wall line, including shear walls sheathed on opposing sides of common framing and assigned shear capacities in accordance with 4.3.5.4.1, shall be permitted to be taken as proportional to the design shear capacities of the individual full-height shear walls provided that the nominal shear capacities of all full-height shear walls with aspect ratios (h/b) greater than 1:1 are multiplied by 0.1+ 0.9b/h . Where multiplied by 0.1+ 0.9b/h, the nominal shear capacities need not be further reduced by the adjustment in 4.3.3.2. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS from 4.3.7 on opposing sides of common framing, provisions of 4.3.5.4.2 apply. Where the shear wall sheathing system on one side of the shear wall is a blocked shear wall and the shear wall sheathing system on the other side of the shear wall is an unblocked shear wall, provisions of 4.3.5.4.2 apply. 4.3.5.4.1 Shear Walls with Similar Shear Wall Sheathing Systems on Opposing Sides of Common Framing: The combined apparent shear wall shear stiffness, Ga(c) and the combined nominal unit shear capacity, νn(sc), shall be determined using the following equations: 33 34 LATERAL FORCE-RESISTING SYSTEMS 4.3.5.6 Shear Capacity of Perforated Shear Walls: The nominal shear capacity, Vn, of a perforated shear wall shall be calculated using the following equation: Table 4.3.5.6 Shear Capacity Adjustment Factor, Co1 1. Definitions of Afhs, Ao, and Awall are provided in Eqn. 4.3-6. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 35 4.3.6 Construction Requirements 4.3.6.1.3 Tension and Compression Chords of Perforated Shear Walls: Each end of each perforated shear wall shall be designed for a tension force, T, and a compression force, C. Each end of each perforated shear wall segment shall be designed for a compression force, C, in each segment. For perforated shear walls, the values for T and C resulting from shear wall overturning at each story level shall be calculated in accordance with the following: 4 4.3.6.2 Sheathing: Shear walls shall be sheathed with approved materials attached directly to the framing members, and blocking where required, except as permitted in 4.3.7.2. Details on sheathing types and thicknesses for commonly used sheathed wood-frame shear wall systems are provided in 4.3.7 and Tables 4.3A, 4.3B, 4.3C, and 4.3D. 4.3.6.3 Fasteners: Sheathing shall be attached to framing members using nails or other approved fasteners. Nails shall be driven with the head of the nail flush with the surface of the sheathing. Other approved fasteners shall be driven as required for proper installation of that fastener. See Appendix A for common, box, and sinker nail dimensions. 4.3.6.3.1 Adhesives: Adhesive attachment of shear wall sheathing shall not be used alone, or in combination with mechanical fasteners. Exception: Approved adhesive attachment systems shall be permitted to resist wind forces, and to resist seismic forces in Seismic Design Category A (see 2.1.2) and in Seismic Design Categories B and C where R = 1.5, Cd=1.5 and Ω0 = 2.5, unless other values are approved. 4.3.6.4 Shear Wall Anchorage and Load Path: Design of shear wall anchorage and load path shall conform to the requirements of this section, or shall be calculated using principles of engineering mechanics. 4.3.6.4.1 Anchorage for In-plane Shear: Connections shall be provided to transfer the unit shear force induced by the design load, ν, into and out of each shear wall. 4.3.6.4.1.1 In-plane Shear Anchorage for Perforated Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 4.3.6.1 Framing Requirements: All framing members and blocking used for shear wall construction shall be 2" nominal or greater. Where shear walls are designed as blocked, all adjoining panel edges shall occur over and be fastened to common framing members or common blocking. Shear wall boundary elements, such as end posts, shall be provided to transmit the design tension and compression forces. Shear wall sheathing shall not be used to splice boundary elements. End posts (studs or columns) shall be framed to provide full end bearing. 4.3.6.1.1 Common Framing Member: Where a common framing member is required at adjoining panel edges, two framing members that are at least 2" in nominal thickness shall be permitted provided they are fastened together with fasteners designed in accordance with the NDS to transfer the shear force induced by the design load between members. When fasteners connecting the two framing members are spaced less than 4" in center, they shall be staggered. 4.3.6.1.2 Tension and Compression Chords: Tension force, T, and a compression force, C, resulting from shear wall overturning forces at each story level shall be calculated in accordance with the following: 36 LATERAL FORCE-RESISTING SYSTEMS Shear Walls: The maximum unit shear force induced by the design load, νmax, transmitted into the top of a perforated shear wall, out of the base of the perforated shear wall at full height sheathing, and into collectors connecting shear wall segments, shall be calculated in accordance with the following: 4.3.6.4.2 Uplift Anchorage at Shear Wall Ends: Where the dead load stabilizing moment is not sufficient to prevent uplift due to overturning moments on the wall (from 4.3.6.1.2 or 4.3.6.1.3), an anchoring device shall be provided at the end of each shear wall. 4.3.6.4.2.1 Uplift Anchorage for Perforated Shear Walls: In addition to the requirements of 4.3.6.4.2, perforated shear wall bottom plates at full height sheathing shall be anchored for a uniform uplift force, t, equal to the maximum unit shear force induced by the design load, νmax, determined in 4.3.6.4.1.1, or calculated by rational analysis. 4.3.6.4.3 Anchor Bolts: Foundation anchor bolts shall have a steel plate washer under each nut not less than 0.229"x3"x3" in size. The hole in the plate washer shall be permitted to be diagonally slotted with a width of up to 3/16" larger than the bolt diameter and a slot length not to exceed 1-3/4", provided a standard cut washer (see Appendix A) is placed between the plate washer and the nut. The plate washer shall extend to within 1/2" of the edge of the bottom plate on the side(s) with sheathing or other material with nominal unit shear capacity greater than 400 plf . Exception: Standard cut washers shall be permitted to be used where anchor bolts are designed to resist shear only and the following requirements are met: a. The shear wall shall be designed in accordance with provisions of 4.3.2.1 with required uplift anchorage at shear wall ends sized to resist overturning neglecting dead load stabilizing moment. b. Shear wall aspect ratio, h:b, shall not exceed 2:1. c. The nominal unit shear capacity of the shear wall shall not exceed 1370 plf. 4.3.6.4.4 Load Path: A load path to the foundation shall be provided for uplift, shear, and compression forces. Elements resisting shear wall forces contributed by multiple stories shall be designed for the sum of forces contributed by each story. 4.3.7 Sheathed Wood-Frame Shear Wall Systems Sheathed wood-frame shear wall systems are described and detailed in the following provisions. Permitted uses and limitations apply only to the specific sheathed wood-frame shear wall system. • Wood Structural Panel shear walls in 4.3.7.1 and 4.3.7.2 • Particleboard shear walls in 4.3.7.3 • Structural Fiberboard shear walls in 4.3.7.4 • Gypsum Board shear walls in 4.3.7.5 • Plaster shear walls in 4.3.7.6 • Single-Layer Diagonally-Sheathed Lumber shear walls in 4.3.7.7 • Double-Layer Diagonally-Sheathed Lumber shear walls in 4.3.7.8 • Horizontally-Sheathed Lumber shear walls in 4.3.7.9 • Vertical Board Siding shear walls in 4.3.7.10 4.3.7.1 Wood Structural Panel Shear Walls: Woodframe shear walls sheathed with wood structural panel sheathing shall be permitted to be used to resist wind and seismic forces. The size and spacing of nails at shear wall boundaries and panel edges shall be as provided in Table 4.3A. The shear wall shall be constructed as follows: 1. Panels shall not be less than 4' x 8', except at boundaries and changes in framing. All edges of all panels shall be supported by and fastened to framing members or blocking. Exception: Horizontal blocking shall be permitted to be omitted, provided that the shear wall is designed in accordance with all of the following: a. The deflection of the unblocked wood structural panel shear wall shall be permitted to be calculated in accordance with Section 4.3.4.2. b. The strength of the unblocked wood structural panel shear wall shall be determined in accordance with Section 4.3.5.3, and c. Specified nail spacing at supported edges shall be 6" o.c. 2. Nails shall be located at least 3/8" from the panel edges. Maximum nail spacing at panel edges shall be 6" on center. 3. Nails along intermediate framing members shall be the same size as nails specified for panel edge nailing. At intermediate framing members, the Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC maximum nail spacing along intermediate framing members shall be 6" on center. Exception: Where panels are thicker than 7/16" (nominal) or studs are spaced less than 24" on center, the maximum nail spacing shall be 12" on center. 4. The width of the nailed face of framing members and blocking shall be 2" nominal or greater. a. Nail spacing of 2" on center at adjoining panel edges is specified, or b. 10d common nails with nail spacing at 3" on center or less at adjoining panel edges are specified, or 4.3.7.3 Particleboard Shear Walls: Wood-frame shear walls sheathed with particleboard sheathing shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, and C. The size and spacing of nails at shear wall boundaries and panel edges shall be as provided in Table 4.3A. The shear wall shall be constructed as follows: 1. Panels shall not be less than 4' x 8', except at boundaries and changes in framing. All edges of all panels shall be supported by and fastened to framing members or blocking. 2. Nails shall be located at least 3/8" from the panel edges. Maximum nail spacing at panel edges shall be 6" on center. 3. Nails along intermediate framing members shall be the same size as nails specified for panel edge nailing. At intermediate framing members, the maximum nail spacing shall be 6" on center. c. The nominal unit shear capacity on either side of the shear wall exceeds 980 plf in Seismic Design Category D, E, or F. In lieu of a single common framing member, two framing members that are at least 2" in nominal thickness shall be permitted where designed in accordance with 4.3.6.1.1. 6. Maximum stud spacing shall be 24" on center. 7. Wood structural panels shall conform to the requirements for its type in DOC PS 1 or PS 2. 4.3.7.1.1 Seismic Equivalency of Alternative Sheathed Wood-Frame Shear Wall Systems: Where seismic equivalency is sought for sheathed wood-frame shear wall systems that use alternative materials or alternative fasteners to those specified for wood structural panel shear walls in 4.3.7.1, seismic equivalency shall be evaluated per ASTM D7989. Use of alternative sheathed wood-frame shear wall systems shall be in accordance with the applicable building code or subject to approval by the authority having jurisdiction. 4.3.7.2 Shear Walls using Wood Structural Panels over Gypsum Wallboard or Gypsum Sheathing Board: Wood-frame shear walls sheathed with wood structural panel sheathing over gypsum wallboard or gypsum sheathing board shall be permitted to be used to resist seismic and wind forces. The size and spacing of nails at shear wall boundaries and panel edges shall be as provided in Table 4.3B. The shear wall shall be constructed in accordance with Section 4.3.7.1. Exception: Where panels are thicker than 3/8" (nominal) or studs are spaced less than 24" on center, the maximum nail spacing shall be 12" on center. 4. The width of the nailed face of framing members and blocking shall be 2" nominal or greater. 5. Where any of the following conditions occur, the width of the nailed face of a common framing member or blocking at adjoining panel edges shall be 3" nominal or greater and nailing shall be staggered at all panel edges: a. Nail spacing of 2" on center at adjoining panel edges is specified, or b. 10d common nails with nail spacing at 3" on center or less at adjoining panel edges are specified. In lieu of a single common framing member, two framing members that are at least 2" in nominal thickness shall be permitted where designed in accordance with 4.3.6.1.1. 6. Maximum stud spacing shall be 24" on center. 7. Particleboard shall conform to ANSI A208.1. 4.3.7.4 Structural Fiberboard Shear Walls: Woodframe shear walls sheathed with fiberboard sheathing shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, and C. The size and spacing of nails at shear wall boundaries and panel edges shall be as provided in Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS 5. Where any of the following conditions occur, the width of the nailed face of a common framing member or blocking at adjoining panel edges shall be 3" nominal or greater and nailing shall be staggered at all panel edges: 37 38 LATERAL FORCE-RESISTING SYSTEMS Table 4.3A. The shear wall shall be constructed as follows: 1. Panels shall not be less than 4' x 8', except at boundaries and changes in framing. All edges of all panels shall be supported by and fastened to framing members or blocking. 2. Nails shall be located at least 3/4" from edges of panels at top and bottom plates and at least 3/8" from all other edges of panels. Maximum nail spacing at panel edges shall be 4" on center. 3. Nails along intermediate framing members and blocking shall be the same size as installed at the panel edges. Maximum nail spacing shall be 6" on center. 4. The width of the nailed face of framing members and blocking shall be 2" nominal or greater at adjoining panel edges. 5. Maximum stud spacing shall be 16" on center. 6. Fiberboard sheathing shall conform to ASTM C 208. 4.3.7.5 Gypsum Board Shear Walls: Wood-frame shear walls sheathed with gypsum wallboard, gypsum base for veneer plaster, water-resistant gypsum backing board, or gypsum sheathing board shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, C, and D. End joints of adjacent courses of gypsum wallboard or gypsum sheathing board, installed with long dimension perpendicular to framing, shall be staggered. The size and spacing of fasteners at shear wall boundaries, panel edges, and intermediate supports shall be as provided in Table 4.3C. Nails shall be located at least 3/8" from the edges and ends of panels. The width of the nailed face of framing members and blocking shall be 2" nominal or greater. 4.3.7.5.1 Gypsum Wallboard, Gypsum Base for Veneer Plaster, Water-Resistant Gypsum Backing Board: Gypsum wallboard, gypsum base for veneer plaster, or water-resistant gypsum backing board shall be applied parallel or perpendicular to studs. Gypsum wallboard shall conform to ASTM C 1396 and shall be installed in accordance with ASTM C 840. Gypsum base for veneer plaster shall conform to ASTM C 1396 and shall be installed in accordance with ASTM C 844. Water-resistant gypsum backing board shall conform to ASTM C 1396 and shall be installed in accordance with ASTM C 840. 4.3.7.5.2 Gypsum Sheathing Board: Four-foot-wide pieces of gypsum sheathing board shall be applied parallel or perpendicular to studs. Two-foot-wide pieces of gypsum sheathing board shall be applied perpendicular to the studs. Gypsum sheathing board shall conform to ASTM C 1396 and shall be installed in accordance with ASTM C 1280. 4.3.7.6 Plaster Shear Walls: Wood-frame shear walls sheathed with gypsum lath and plaster or Portland cement plaster shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, C, and D. The size and spacing of fasteners shall be as provided in Table 4.3C. The width of the nailed face of framing members and blocking shall be 2" nominal or greater. 4.3.7.6.1 Gypsum Lath and Plaster: Gypsum lath shall be applied perpendicular to the studs. Gypsum lath shall conform to ASTM C 1396 and shall be installed in accordance with ASTM C 841. Gypsum plaster shall conform to the requirements of ASTM C 28. 4.3.7.6.2 Expanded Metal or Woven Wire Lath and Portland Cement: Expanded metal or woven wire lath and portland cement shall conform to ASTM C 847, ASTM C 1032, and ASTM C 150 and shall be installed in accordance with ASTM C 926 and ASTM C 1063. Metal lath and lath attachments shall be of corrosion-resistant material. 4.3.7.7 Single-Layer Diagonally-Sheathed Lumber Shear Walls: Single-layer diagonally-sheathed lumber shear walls shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, C, and D. Single-layer diagonally sheathed lumber shear walls shall be constructed of minimum 1" thick nominal sheathing boards laid at an angle of approximately 45° to the supports. End joints in adjacent boards shall be separated by at least one stud space and there shall be at least two boards between joints on the same support. Nailing of diagonally sheathed lumber shear walls shall be in accordance with Table 4.3D. 4.3.7.8 Double-Layer Diagonally-Sheathed Lumber Shear Walls: Double-layer diagonally-sheathed lumber shear walls shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, C, and D. Double-layer diagonally sheathed lumber shear walls shall be constructed of two layers of 1" thick nominal diagonal sheathing boards laid perpendicular to each other on the same face of the supporting members. Nailing of diagonally sheathed lumber shear walls shall be in accordance with Table 4.3D. 4.3.7.9 Single-Layer Horizontally-Sheathed Lumber Shear Walls: Single-layer horizontally-sheathed lumber shear walls shall be permitted to be used to resist wind Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Design Categories A (see 2.1.2), B, and C. Vertical board siding shear walls shall be constructed of minimum 1" thick nominal sheathing boards applied directly to studs and blocking. Nailing of vertical board siding shear walls shall be in accordance with Table 4.3D. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS forces, and to resist seismic forces in Seismic Design Categories A (see 2.1.2), B, and C. Single-layer horizontally-sheathed lumber shear walls shall be constructed of minimum 1" thick nominal sheathing boards applied perpendicular to the supports. End joints in adjacent boards shall be separated by at least one stud space and there shall be at least two boards between joints on the same support. Nailing of single-layer horizontally- sheathed lumber shear walls shall be in accordance with Table 4.3D. 4.3.7.10 Vertical Board Siding Shear Walls: Vertical board siding shear walls shall be permitted to be used to resist wind forces, and to resist seismic forces in Seismic 39 40 LATERAL FORCE-RESISTING SYSTEMS Table 4.3A Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls 1,3,6 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements, see 4.3.7.1 for wood structural panel shear walls, 4.3.7.3 for particleboard shear walls, and 4.3.7.4 for fiberboard shear walls. See Appendix A for common and box nail dimensions. 2. Nominal unit shear capacities are permitted to be increased to values shown for 15/32 inch (nominal) sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches on center, or (b) panels are applied with long dimension across studs. 3. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. 4. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2. 5. Where moisture content of the framing is greater than 19% at time of fabrication, Ga values shall be multiplied by 0.5. 6. Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at all panel edges shall be staggered. 7. Galvanized nails shall be hot-dipped or mechanically deposited. 8. Galvanized box nails shall be permitted to be substituted for the specified common nails as shown in the table below. 9. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. 10. Where tension force induced by shear wall overturning is resisted by a hold-down attached to the inside face of the end post, nominal unit shear capacity for shear walls using 10d common nails shall be multiplied by 0.92. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 41 Table 4.3B Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls 1,2,5,6 4 8. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements, see 4.3.7.2 for wood structural panel shear walls over gypsum board. See Appendix A for common and box nail dimensions. Nominal unit shear capacities are permitted to be increased to values shown for 15/32 inch (nominal) sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches on center, or (b) panels are applied with long dimension across studs. 2. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2. 3. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with either OSB or 3-ply plywood panels. When 4-ply, or 5-ply plywood panels or composite panels are used, Ga values shall be permitted to be increased by 1.2.Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members as shown below. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at all panel edges shall be staggered. 4. Where moisture content of the framing is greater than 19% at time of fabrication, Ga values shall be multiplied by 0.5. 5. Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members as shown below. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at all panel edges shall be staggered. 6. Galvanized nails shall be hot-dipped or tumbled mechanically deposited. 7. Galvanized box nails shall be permitted to be substituted for the specified common nails as shown in the table below. 42 LATERAL FORCE-RESISTING SYSTEMS Table 4.3C Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls 1 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements see 4.3.7.5 and 4.3.7.6. 2. Type S or W drywall screws shall conform to requirements of ASTM C 1002. 3. Where two numbers are given for maximum fastener spacing, the first number denotes fastener spacing at the edges and the second number denotes fastener spacing in the field. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 43 Table 4.3D Nominal Unit Shear Capacities for Sheathed Wood-Frame Shear Walls 1 4 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 1. Nominal unit shear capacities shall be adjusted in accordance with 4.1.4 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements, see 4.3.7.7 through 4.3.7.10. See Appendix A for common and box nail dimensions. 2. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. LATERAL FORCE-RESISTING SYSTEMS 44 4.4 Wood Structural Panels Used in Walls Designed to Resist Combined Shear and Uplift from Wind bined uplift and shear forces developed in the wall. Anchors shall be spaced at in accordance with Table 4.4.1.6. 4.4.1 Application Walls sheathed with wood structural panel sheathing or siding shall be permitted to be designed for simultaneously resisting shear and uplift from wind forces. The ASD allowable unit uplift capacity shall be determined by dividing the tabulated nominal uplift capacity in Table 4.4.1 by the ASD reduction factor of 2.0. The LRFD factored unit uplift resistance shall be determined by multiplying the tabulated nominal uplift capacity in Table 4.4.1 by a resistance factor, ϕz, of 0.65. Uplift anchorage at shear wall ends shall be designed in accordance with 4.3.6.4.2. 4.4.1.1 Nails: Nails in any single row shall not be spaced closer than 3" on center. 4.4.1.2 Panels: Panels shall have a minimum nominal panel thickness of 7/16" and shall be installed with the strength axis parallel or perpendicular to the studs. 4.4.1.3 Horizontal Panel Edges: All horizontal adjoining panel edges shall occur over and be fastened to common framing members or common blocking and shall meet all other requirements of Section 4.3. 4.4.1.4 Openings: Where windows and doors interrupt wood structural panel sheathing or siding, framing anchors or connectors shall be provided to resist and transfer the appropriate uplift loads around the opening and into the foundation. 4.4.1.5 Sheathing Extending to Top Plate: The following requirements shall apply: 1. The top edge of the wood structural panel shall be attached to the upper top plate. Nail row, end spacing, and edge spacing shall be as shown in Figure 4G. 2. Roof or upper level uplift connectors shall be on the same side of the wall as the sheathing unless other methods are used to prevent twisting of the top plate due to eccentric loading. 4.4.1.6 Sheathing Extending to Bottom Plate or Sill Plate: The following requirements shall apply: 1. The bottom edge of the wood structural panel shall extend to and be attached to the bottom plate or sill plate as shown in Figure 4G. 2. Anchorage of bottom plates or sill plates to the foundation shall be designed to resist the com- a. Where anchor bolts are used, a minimum 0.229" x 3" x 3" steel plate washer shall be used at each anchor bolt location. The edge of the plate washer shall extend to within 1/2" of the edge of the bottom plate on the sheathed side. b. Where other anchoring devices are used to anchor the wall to the foundation, they shall be installed on the same side of the wall as the sheathing unless other approved methods are used. 3. An anchor bolt shall be provided at each end of each plate. Anchor bolts at the end of the plate shall be at least 7 times the anchor bolt diameter from the end, but not more than ½ the tabulated anchor bolt spacing in accordance with Table 4.4.1.6 or 12", whichever is less. Exception: Where a hold-down anchor is used at the end of the plate, the end distance shall be permitted to be measured from the anchor bolt to the center of the hold-down anchor. 4.4.1.7 Sheathing Splices: 1. In multi-story applications where the upper story and lower story sheathing adjoin over a common horizontal framing member, the nail spacing shall not be less than 3" o.c. for a single row nor 6" o.c. for a double row in Table 4.4.1 (see Figure 4H). 2. In single or multi-story applications where horizontal adjoining panel edges occur over and are fastened to blocking between studs, nailing of the sheathing to the studs above and below the adjoining panel edge shall be designed to transfer the uplift across the adjoining panel edge (see Figure 4I). The uplift capacity shall not exceed the capacity in Table 4.4.1. Blocking shall be designed in accordance with Section 4.4.1.3 for shear transfer. Exception: Horizontal blocking and sheathing ten- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC sion splices placed between studs and backing the horizontal adjoining panel edge shall be permitted to be used to resist both uplift and shear at sheathing splices over studs provided the following conditions are met (see Figure 4J): a. Sheathing tension splices shall be made from the same thickness and grade as the shear wall sheathing. Figure 4G 4.4.2 Wood Structural Panels Used in Walls Designed to Resist Only Uplift from Wind Walls sheathed with wood structural panel sheathing or siding shall be permitted to be designed for simultaneously resisting shear and uplift from wind Where walls sheathed with wood structural panel sheathing or siding are designed to resist only uplift from wind forces, they shall be in accordance with Section 4.4.1, except that panels with a minimum nominal panel thickness of 3/8" shall be permitted when installed with the strength axis parallel to the studs. The ASD allowable unit uplift shall be determined by dividing the tabulated nominal uplift capacity in Table 4.4.2 by the ASD reduction factor of 2.0. The LRFD factored uplift resistance shall be determined by multiplying the tabulated nominal unit uplift capacity in Table 4.4.2 by a resistance factor, ϕZ, of 0.65. Panel Attachment Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS b. Edges of sheathing shall be nailed to sheathing tension splices using the same nail size and spacing as the sheathing or siding nails at the bottom plate. 45 46 LATERAL FORCE-RESISTING SYSTEMS Figure 4H Panel Splice Occurring over Horizontal Framing Member Figure 4I Panel Splice Occurring across Studs Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Figure 4J 47 Sheathing Splice Plate (Alternate Detail) 4 LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 48 LATERAL FORCE-RESISTING SYSTEMS Table 4.4.1 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Both Shear Walls and Wind Uplift Simultaneously over Framing with a Specific Gravity of 0.42 or Greater 1 1. Nominal unit uplift capacities shall be adjusted in accordance with 4.4.1 to determine ASD allowable unit uplift capacity and LRFD factored unit resistance. Anchors shall be installed in accordance with this section. See Appendix A for common nail dimensions. 2. Where framing has a specific gravity of 0.49 or greater, uplift capacities in table 4.4.1 shall be permitted to be multiplied by 1.08. 3. Where nail size is 6d common or 8d common, the tabulated uplift capacities are applicable to 7/16" OSB panels or 15/32" plywood with species of plies having a specific gravity of 0.49 or greater. Where nail size is 10d common, the tabulated uplift capacities are applicable to 15/32" OSB or 15/32" plywood with a species of plies having a specific gravity of 0.49 or greater. For plywood with other species, multiply the tabulated uplift capacities by 0.90. 4. Wood structural panels shall overlap the top member of the double top plate and bottom plate by 1-1/2" and a single row of nails shall be placed ¾" from the panel edge. 5. Wood structural panels shall overlap the top member of the double top plate and bottom plate by 1-1/2". Rows of nails shall be ½" apart with a minimum edge distance of ½". Each row shall have nails at the specified spacing. Table 4.4.1.6 Maximum Anchor Bolt Spacing (inches) for Combined Shear and Wind Uplift1,2 G = Specific Gravity of framing members - Not Permitted 1. The minimum nominal panel thickness of wall sheathing shall be in accordance with Section 4.4.1.2. 2. Tabulated anchor bolt spacings are for minimum ½" diameter “full-body diameter” bolts (see NDS Appendix Table L1). 3. This anchor bolt spacing is provided for interpolation purposes. 4. Tabulated nominal unit shear and uplift capacities are applicable for carbon steel smooth shank nails of the specified type and size. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 49 Table 4.4.2 Nominal Uplift Capacity of Wood Structural Panel Sheathing or Siding When Used for Wind Uplift Only over Framing with a Specific Gravity of 0.42 or Greater 1 4 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL LATERAL FORCE-RESISTING SYSTEMS 1. Nominal unit uplift capacities shall be adjusted in accordance with 4.4.2 to determine ASD allowable unit uplift capacity and LRFD factored unit resistance. Anchors shall be installed in accordance with this section. See Appendix A for common nail dimensions. 2. Where framing has a specific gravity of 0.49 or greater, uplift capacities in table 4.4.2 shall be permitted to be multiplied by 1.08. 3. The tabulated uplift capacities are applicable to 3/8" OSB panels or 3/8" plywood with species of plies having a specific gravity of 0.49 or greater. For plywood with other species, multiply the tabulated uplift capacities by 0.90. 4. Wood structural panels shall overlap the top member of the double top plate and bottom plate by 1-1/2" and a single row of nails shall be placed ¾" from the panel edge. 5. Wood structural panels shall overlap the top member of the double top plate and bottom plate by 1-1/2". Rows of nails shall be ½" apart with a minimum edge distance of ½". Each row shall have nails at the specified spacing. 6. Tabulated nominal unit capacities are applicable for carbon steel smooth shank nails of the specified type and size. LATERAL FORCE-RESISTING SYSTEMS 50 4.5 Cross-Laminated Timber (CLT) Diaphragms tener yielding in accordance with NDS 12.3.1. 4.5.1 Application Requirements CLT diaphragms shall be permitted to be used to resist lateral forces provided the deflection in the plane of the diaphragm, as determined by calculations, tests, or analogies drawn therefrom, does not exceed the maximum permissible deflection limit of attached load distributing or resisting elements. Permissible deflection shall be that deflection that will permit the diaphragm and any attached elements to maintain their structural integrity and continue to support their prescribed loads as determined by the applicable building code or standard. 2. Connections used to transfer diaphragm shear forces shall not be used to resist diaphragm tension forces. 3. Wood elements, steel parts, and wood or steel chord splice connections shall be designed for 2.0 times the diaphragm forces associated with the shear forces induced from the design loads. 4.5.2 Deflection CLT diaphragm deflection shall be determined using principles of engineering mechanics. 4.5.3 Unit Shear Capacity CLT diaphragms shall be designed in accordance with principles of engineering mechanics using design values for wood members and connections in accordance with NDS provisions. The nominal unit shear capacity, vn, of CLT diaphragms shall be based on the nominal shear capacity for dowel-type fastener connections used to transfer diaphragm shear forces, as calculated per 4.5.4, Item 1. ASD allowable shear capacity or LRFD factored shear resistance for the CLT diaphragm and diaphragm shear connections shall be determined in accordance with 4.1.1. Exceptions: 1. Wood elements and wood splice connections shall be permitted to be designed for 1.5 times the diaphragm forces associated with the shear forces induced by the wind design loads. 2. Where dowel-type fasteners are used in chord splice connections and the connection is controlled by Mode IIIs or Mode IV fastener yielding in accordance with NDS 12.3.1, fasteners in the connection shall be permitted to be designed for 1.5 and 1.0 times the diaphragm forces associated with the shear forces induced by the prescribed seismic and wind design loads, respectively. Diaphragm chord elements and chord splice connections using materials other than wood or steel shall be designed using provisions in NDS 1.4. 4.5.4 Additional CLT Diaphragm Design Requirements CLT diaphragms shall meet the following additional requirements: 1. The nominal shear capacity for dowel-type fastener connections used to transfer diaphragm shear forces between CLT panels and between CLT panels and diaphragm boundary elements (chords and collectors) shall be taken as 4.5Z*, where Z* is Z multiplied by all applicable NDS adjustment factors except CD, KF, ϕ, and λ; and Z shall be controlled by Mode IIIs or Mode IV fasCopyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 51 4.6 Cross-Laminated Timber (CLT) Shear Walls 4.6.1 Application 4.6.2 Deflection CLT shear wall deflection shall be determined using principles of engineering mechanics. 4.6.3 Shear Capacities 4.6.3.1 ASD allowable shear capacity or LRFD factored shear resistance for CLT shear wall systems shall be determined in accordance with 4.1.1. 4.6.3.2 Nominal Unit Shear Capacities: Nominal unit shear capacities for CLT shear wall systems used to resist wind or seismic forces shall be in accordance with the requirements in Appendix B, where design and construction is in accordance with Appendix B. Exception: Approved CLT shear wall systems, other than those in accordance with Appendix B, shall be permitted to resist wind forces, and to resist seismic forces in Seismic Design Category A (see 2.1.2) and in Seismic Design Category B where R=1.5, Cd=1.5 and Ωo=2.5, and with structural height limit of 65', unless other values are approved. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 4 LATERAL FORCE-RESISTING SYSTEMS CLT shear walls shall be permitted to resist lateral forces provided the deflection of the shear wall, as determined by calculations, tests, or analogies drawn therefrom, does not exceed the maximum permissible deflection limit. Permissible deflection shall be that deflection that will permit the shear wall and any attached elements to maintain their structural integrity and continue to support their prescribed loads as determined by the applicable building code or standard. 52 LATERAL FORCE-RESISTING SYSTEMS This page is intentionally left blank. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 53 APPENDIX A Table A1 Standard Common, Box, and Sinker Nails...........54 Table A2 Standard Cut Washers............................................54 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL A 54 APPENDIX A Table A1 Standard Common, Box, and Sinker Nails1 Table A2 Standard Cut Washers Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 55 APPENDIX B (Mandatory) Requirements for CLT Shear Walls.........................56 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL B 56 APPENDIX B (Mandatory) Requirements for CLT Shear Walls shall be in accordance with B.3.3. Holddown systems in accordance with B.3.4 are not required. B.1 Scope These provisions shall be used for the design and construction of structural cross-laminated timber (CLT) members and connections that are part of the lateral force-resisting system. Capacity design principles are employed to ensure development of the expected shear capacity of the prescribed nailed connectors of the CLT shear wall. The provisions provided herein shall be applied in combination with the requirements of this Standard, NDS including Appendix E, ASCE 7, and the applicable building code. 4. CLT walls that are not part of the designated SFRS shall be designed so that the action or failure of those elements will not impair the vertical load and seismic force-resisting capability of the designated SFRS. B.2 Application Requirements The design and construction of the CLT lateral force-resisting system (LFRS) shall comply with all of the following: 1. The method of construction shall be platform construction in accordance with the following: a. CLT floor panels bear on and are supported by CLT shear walls that are part of the designated LFRS. Additional gravity support is permitted to be provided by other gravity framing system elements including but not limited to CLT walls that are not part of the designated LFRS, beams, columns, and light-frame walls. b. CLT floor panels are designed as the floor diaphragm to distribute lateral loads to the CLT shear walls. 2. CLT walls shall be classified as either (1) part of the designated LFRS (i.e. CLT shear wall) or (2) not part of the designated LFRS. 3. CLT walls that are not part of the designated LFRS shall meet the following requirements: a. CLT panels forming either a single-panel or multi-panel wall shall have an aspect ratio, h/bs, that is not less than the aspect ratio used for CLT shear wall panels in accordance with B.3.1 or B.3.7. b. Shear connections at the top and bottom of CLT wall panels shall be in accordance with B.3.2. Where shear connections are provided at adjoining vertical panel edges to form a multi-panel CLT wall, such connections a. The design shall provide for the effect of the CLT walls that are not part of the designated SFRS on the structural system at deformations corresponding to the design story drift, the distribution of forces to the structural system, and the corresponding load path to the final point of resistance; this shall be achieved by design for the most critical demands to vertical gravity load supporting elements, vertical SFRS elements, and diaphragms, and their load paths, determined in accordance with both of the following: i. Force and deformation demands determined including in the analysis CLT shear walls of the designated SFRS, but neglecting in-plane shear strength and stiffness of CLT walls that are not part of the designated SFRS, and ii. Force and deformation demands determined including in the analysis both CLT shear walls of the designated SFRS, and CLT walls that are not part of the designated SFRS. b. In addition, the effects of CLT walls classified as not part of the designated SFRS shall be considered where determining whether a structure has one or more of the irregularities defined in ASCE 7 12.3.2 based on the two analysis cases in accordance with item 4a. c. Where the fundamental period of the structure is calculated in accordance with ASCE 7 using the structural properties and deformational characteristics, it shall include the effects of stiffness of CLT walls classified as not part of the designated SFRS. d. For the purpose of Items 4a, 4b and 4c, CLT wall panels that are classified as not part of the designated SFRS shall be modeled as- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC suming they develop in-plane shear strength and stiffness associated with CLT shear walls of the same construction. 5. Shear distribution to individual CLT shear walls in a wall line shall provide the same calculated deflection in each shear wall (i.e. distribution of loads based on relative stiffness). 7. CLT shear walls shall be full-height within each story. CLT shear walls are not permitted to be designed as Force-Transfer Around Openings (FTAO) shear walls or as Perforated Shear Walls. 8. The nominal unit shear capacity assigned to CLT shear walls shall not include contributions from connections other than those shear connections prescribed in B.3.2 and B.3.3. 9. ASCE 7 seismic criteria specific to light-frame construction shall not apply to the design of CLT shear walls and CLT diaphragms. B.3 CLT Shear Wall Requirements B.3.1 CLT Panels CLT panels used in CLT shear walls shall be designed in accordance with the NDS and the following requirements: 1. CLT in-service moisture content shall be less than 16% and specific gravity, G, shall be 0.35 or greater. 2. CLT panels forming either a single-panel or multi-panel shear wall shall have aspect ratio, h/ bs, not greater than 4 nor less than 2. All CLT panels forming a multi-panel shear wall shall have the same panel height, h, and individual panel length, bs. 3. CLT panels shall be a minimum of 3.5 in. in thickness. Where angle connectors or vertical edge connectors are installed in both faces of the CLT panel and are directly opposed, CLT panels shall be a minimum of 6.875 in. in thickness so that nails from opposing faces do not overlap. 4. Holes, notches and other modifications to CLT panels shall not be permitted unless the effects of removal of material on load carrying capacity of the CLT panel is determined by an approved rational analysis. B.3.2 Top and Bottom of Wall Angle Connector Shear connections at the top and bottom of CLT shear walls shall be composed of prescribed steel angle connectors, nails, and bolts in accordance with the following requirements: 1. Angle connectors shall be fabricated from 0.105 in. thickness, ASTM A653 Grade 33 steel sheet with the geometry as illustrated in Figure B.3.2. 2. Vertical legs of angle connectors shall be fastened to wall panel using (8) 16d carbon steel box nails (3.5 in. length x 0.135 in. shank diameter x 0.344 in. head diameter) with bright finish in accordance with ASTM F1667 including Supplementary Requirements of ASTM F1667 S1 Nail Bending Yield Strength. 3. Horizontal legs of angle connectors shall be fastened to supporting elements (e.g. CLT floor or roof panels, concrete foundation elements, or roof framing elements other than CLT) with (2) 5/8in. diameter x 4-1/2 in. long (minimum) bolts to provide minimum 4-1/2in. bearing length with washer per ASME B18.21.1, or (2) 5/8 in. fullbody diameter lag screws with 2-3/4 in. thread penetration (minimum) excluding tapered tip and 3-1/8 in. unthreaded shank length (minimum) to provide minimum 5-7/8 in. bearing length and with washer per ASME B18.21.1. Bolts and lag screws shall be ASTM A307 Grade A or higher. The anchorage, foundation, and other supporting elements shall be capable of resisting a concurrent tension force and shear force transmitted through horizontal leg fasteners, with force in each direction equal to the connector nominal shear capacity. The design of the 5/8 in. diameter anchor to concrete foundation or other concrete elements shall be in accordance with ACI 318 and the prescribed loading above shall be considered to meet the ductile yield mechanism requirement of ACI 318. 4. Angle connectors at the bottom and top of wall panels shall extend to within 12 in. of each end of each panel of a single or multi-panel shear wall. 5. Each wall panel shall have at least two angle connectors at the top and bottom. The same number of angle connectors shall be provided at the top and bottom of each wall panel. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL B APPENDIX B 6. The dead load considered in the overturning design of each individual CLT panel within the CLT shear wall shall be limited to the dead load supported by or directly above the individual CLT panel. 57 58 APPENDIX B Figure B.3.2 Top and Bottom of Wall Angle Connector B.3.4 Hold-down System Each end of each shear wall shall be provided with a hold-down system. Hold-down systems shall comply with the following: 1. Hold-down systems shall consist of continuous tie-rod systems or conventional hold-down devices that use threaded anchor rods and nail, screw or bolt attachment to the CLT panel. B.3.3 Adjoining Panel Edge Connector In CLT multi-panel shear walls, shear connections at adjoining vertical panel edges of CLT wall panels shall be composed of prescribed steel plate connectors and nails in accordance with the following requirements: 1. Plate connector shall be fabricated from 0.105 in. thickness, ASTM A653 Grade 33 steel sheet with the geometry as illustrated in Figure B.3.3. 2. Plate connectors shall be fastened to each wall panel using (8) 16d carbon steel box nails (3.5 in. length x 0.135 in. shank diameter x 0.344 in. head diameter) with bright finish in accordance with ASTM F1667 including Supplementary Requirements of ASTM F1667 S1 Nail Bending Yield Strength. 3. The number of plate connectors required at adjoining vertical edges of CLT panels shall equal the number of angle connectors along the bottom edge of the wall panel times the CLT panel aspect ratio, h/bs, rounded up to the next whole number. Figure B.3.3 Adjoining Panel Edge Connector 2. Where continuous tie-rod systems are used, rods at each level shall be designed for cumulative overturning tensile forces and bearing plates shall be provided at the floor level above each story Tie-rod elongation or conventional holddown device deformation for each story shall not exceed 0.185 in. when applying strength design load combinations of ASCE 7. 3. The hold-down system including anchorage to the foundation shall be designed to resist not less than 2.0 times the forces associated with the design shear capacity of the CLT shear wall determined in accordance with 4.1.4.1 for seismic and 1.5 times the forces associated with the design shear capacity of the CLT shear wall in accordance with 4.1.4.2 for wind. Connections between the hold-down device and CLT panel shall comply with net section tension rupture, row tear-out, group tear-out in accordance with NDS Appendix E. The anchorage to foundation shall be designed in accordance with ACI 318. B.3.5 Compression Zone The length of the compression zone for overturning compression forces induced by the design loads shall be determined to satisfy static equilibrium assuming a uniform distribution of bearing stress in the compression zone. For multi-panel shear walls, the compression zone shall be contained within the outermost wall panel. CLT wall panel resistance to induced axial compression forces shall be determined using cross section dimensions associated with the compression zone. B.3.6 Other Load Path Connections to CLT Wall Panels Connections to CLT wall panels in addition to those connections prescribed in B.3.2 and B.3.3 shall be provided in accordance with 4.1.1 to provide a continuous load path. Load path connections to CLT wall panels shall be with dowel-type fasteners designed to develop Mode IIIs or Mode IV yielding, and com- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 59 ply with net section tension rupture, row tear-out, group tear-out in accordance with NDS Appendix E. Screws (e.g. wood screws and lag screws) shall not be used in supplemental top and bottom of wall connections to supporting elements. Angle connectors prescribed in B.3.2 shall not be considered in design to resist out-of-plane forces. b. All CLT wall panels that are not part of the designated lateral force-resisting system shall have aspect ratio, h/bs, not less than 4. B B.5 Nominal Unit Shear Capacity Nominal unit shear capacity, vs, shall be in accordance with Equation B-2. Where both faces of a panel are provided with angle connectors in accordance with B.3.2, the nominal unit shear capacity shall be permitted to be taken as the sum of the nominal unit shear capacities of each face. B.4 Deflection CLT shear wall deflection, δSW, shall be calculated by use of the following equation: B.6 ASD and LRFD Design Unit Shear Capacities The LRFD factored unit shear resistance and the ASD allowable unit shear capacity shall be determined in accordance with 4.1.1. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL APPENDIX B B.3.7 CLT Shear Walls with Shear Resistance Provided by High Aspect Ratio Panels Only CLT shear walls with shear resistance provided by high aspect ratio panels only shall meet all requirements applicable for CLT shear walls and the following: a. All CLT wall panels used as part of the designated lateral force-resisting system shall have aspect ratio, h/bs, equal to 4, and 60 APPENDIX B This page is intentionally left blank. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 61 REFERENCES Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL R REFERENCES 62 References 1. ANSI/ASME B18.21.1-2009, Washers: Helical Spring-Lock, Tooth Lock, and Plain Washers (Inch Series), American Society of Mechanical Engineers, New York, NY, 2009. 2. ANSI/AWC NDS-2018, National Design Specification (NDS) for Wood Construction, American Wood Council, Leesburg, VA, 2017. 3. ANSI A208.1-2016, Particleboard, ANSI, New York, NY, 2016. 4. ANSI/CPA A135.6 Engineered Wood Siding, Composite Panel Association, Gaithersburg, MD, 2012. 5. ASTM C1396/C1396M-17, Standard Specification for Gypsum Board, ASTM International, West Conshohocken, PA, 2017. 6. ASCE/SEI Standard 7-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers, Reston, VA, 2016. 7. ASTM C28/C28M-10 (2015), Standard Specification for Gypsum Plasters, ASTM International, West Conshohocken, PA, 2015. 8. ASTM C150M-18, Standard Specification for Portland Cement, ASTM International, West Conshohocken, PA, 2018. 9. ASTM C208-12 (2017) e2, Standard Specification for Cellulosic Fiber Insulating Board, ASTM International, West Conshohocken, PA, 2017. 10. ASTM C840-18b, Standard Specification for Application and Finishing of Gypsum Board, ASTM International, West Conshohocken, PA, 2018. 11. ASTM C841-03 (2018), Standard Specification for Installation of Interior Lathing and Furring, ASTM International, West Conshohocken, PA, 2018. 12. ASTM C844-15, Standard Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster, ASTM International, West Conshohocken, PA, 2015. 13. ASTM C847-18, Standard Specification for Metal Lath, ASTM, West Conshohocken, PA, 2018. 14. ASTM C926-18b, Standard Specification for Application of Portland Cement-Based Plaster, ASTM International, West Conshohocken, PA, 2018. 15. ASTM C1002-18 Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs, ASTM International, West Conshohocken, PA, 2018. 16. ASTM C1032-18, Standard Specification for Woven Wire Plaster Base, ASTM International, West Conshohocken, PA, 2018. 17. ASTM C1063-19a, Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster, ASTM International, West Conshohocken, PA, 2019. 18. ASTM C1280-18, Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing, ASTM International, West Conshohocken, PA, 2018. 19. ASTM F1667-18a, Standard Specification for Driven Fasteners: Nails, Spikes, and Staples, ASTM International, West Conshohocken, PA, 2018. 20. PS 1-19 Structural Plywood, United States Department of Commerce, National Institute of Standards and Technology, Gaithersburg, MD, 2019. 21. PS 2-18 Performance Standard for Wood Structural Panels, United States Department of Commerce, National Institute of Standards and Technology, Gaithersburg, MD, 2018. 22. ASTM D7989-18, Standard Practice for Demonstrating Equivalent In-Plane Lateral Seismic Performance to Wood-Frame Shear Walls Sheathed with Wood Structural Panels, ASTM International, West Conshohocken, PA, 2018. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 63 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC SDPWS COMMENTARY C2 General Design Requirements 65 C3 Members and Connections 67 C4 Lateral Force-Resisting Systems 73 Commentary to Appendix B 125 Commentary References 139 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C 64 SDPWS COMMENTARY FOREWORD The Special Design Provisions for Wind and Seismic (SDPWS) standard was first issued in 2001. It contains provisions for materials, design, and construction of wood members, fasteners, and assemblies to resist wind and seismic forces. The 2021 edition is the fifth edition of this standard. The Commentary to the SDPWS is provided herein and includes background information for most sections as well as sample calculations for many of the design value tables. The Commentary follows the same subject matter organization as the SDPWS. Discussion of a particular provision in the SDPWS is identified in the Commentary by the same section or subsection. When available, references to more detailed information on specific subjects are included. In developing the provisions of the SDPWS, data and experience with structures in-service has been carefully evaluated by the AWC Wood Design Standards Committee for the purpose of providing a standard of practice. It is intended that this standard be used in conjunction with competent engineering design, accurate fabrication, and adequate supervision of construction. Therefore, AWC does not assume any responsibility for errors or omissions in the SDPWS and SDPWS Commentary, nor for engineering designs and plans prepared from it. Inquiries, comments, and suggestions from the readers of this document are invited. American Wood Council Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 65 C2 GENERAL DESIGN REQUIREMENTS C2.1 General C2.1.3 Sizes Allowable stress design (ASD) and load and resistance factor design (LRFD) provisions are applicable for the design of wood members and systems to resist wind and seismic loads. For other than short-term wind and seismic loads (10-minute basis), adjustment of design capacities for load duration or time effect shall be in accordance with the National Design Specification® (NDS®) for Wood Construction (6). Design for wind-borne debris is beyond the scope of this standard. Requirements for the design for wind-borne debris may be found in applicable building codes. Sizes of wood products vary by both product type and end use conditions. Actual wood product dimensions are typically a function of moisture content at the time that measurements are taken. For this reason, dimensions are reported in terms of reference environmental conditions. Products such as lumber, timbers, and wood structural panels have been historically reported in terms of “nominal” dimension nomenclature. These product names are associated with minimum dimensions at reference environmental conditions or a reference moisture content specification for the manufacturing process as described in the product standards. For example, the minimum dressed dry dimensions of a “2x4” are 1.5 inches x 3.5 inches for the moisture content specification that permits the lumber to be marked as “S Dry”. Similarly, wood structural panels are described in terms of “Performance Category” descriptors which are related to the panel thickness range at reference environmental conditions described as “nominal panel thickness” in this standard. Use of the term “nominal panel thickness” is consistent with terminology used in previous versions of this standard and the U.S. model building codes. Common Performance Categories and Span Ratings are provided in Table C4.2.2C. C2.1.2 Design Methods Engineered design of wood structures to resist wind and seismic forces is intended to be in accordance with the applicable building code or, in the absence of an applicable building code, ASCE 7 – Minimum Design Loads and Associated Criteria for Buildings and Other Structures (5). Both ASD and LRFD (also referred to as strength design) formats are addressed by reference to the National Design Specification® (NDS®) for Wood Construction (6) for design of wood members and connections. The design of elements throughout a structure will generally utilize either the ASD or LRFD format; however, specific requirements to use a single design format for all elements within a structure are not included. The suitability of mixing formats within a structure is the responsibility of the designer in compliance with requirements of the authority having jurisdiction. ASCE 7 limits mixing of design formats to cases where there are changes in materials. For more information on ASCE 7 General Structural Integrity, see ASCE 7 Commentary for requirements and information on structural integrity. The requirement for general structural integrity does not negate the requirement for design of the lateral force-resisting system to resist wind. C2.1.4 Use of Standard Where footnotes are used in SDPWS tables, those footnotes are a mandatory part of the tables. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: GENERAL DESIGN REQUIREMENTS C2.1.1 Scope 66 COMMENTARY: GENERAL DESIGN REQUIREMENTS C2.2 Terminology Nominal Strength: Nominal strength (or nominal capacity) is used to provide a common reference point from which to derive ASD or LRFD reference design values. For wood structural panel shear walls and diaphragms, tabulated nominal unit shear capacities, νn, (nominal strength) were derived using ASD tabulated seismic design values from industry design documents and model building codes (2, 18, 19, 20) times a factor of 2.8. The factor of 2.8, based on minimum performance requirements for lateral performance in a monotonic load test (8), has commonly been considered the target minimum safety factor associated with ASD unit shear capacity for wood structural panel sheathed wood-frame shear walls and diaphragms in seismic applications. For fiberboard and lumber-sheathed shear walls and lumber-sheathed diaphragms, similar assumptions were used. For shear walls utilizing gypsum board, gypsum lath and plaster, and Portland cement plaster, ASD unit shear capacity values from model building codes (2) were multiplied by 2.0 to develop nominal unit shear capacity values. While varying approaches are used across the variety of products (e.g., wood structural panels, lumber sheathing, structural fiberboard) and applications (e.g., shear walls, diaphragms, wall sheathing, and roof sheathing) covered by SDPWS, the most common basis of nominal strength is the factoring up of historic ASD design values such that when nominal strength is divided by the specified ASD reduction factor, the identical design value to that specified in prior codes will result. An exception is shear walls utilizing gypsum board, gypsum lath and plaster, or Portland cement plaster where ASD seismic design values are approximately 30% smaller in 2021 SDPWS than specified in prior versions due to consistent application of the ASD reduction factor of 2.8 for shear wall systems covered by the standard. Nominal strength values and methods of adjusting values for use as part of engineered design using either ASD or LRFD (e.g., ASD reduction factors or LRFD resistance factors) are based upon the premise that the structural products fully comply with the applicable product standards referenced in this Standard. For example, wood structural panels used in shear wall and diaphragm applications or as wall and roof sheathing must conform to the requirements found in DOC PS 1 (58) or PS 2 (8), as applicable. These product standards include minimum performance requirements, applicable test methods, and quality assurance for which design methods in this Standard are considered suitable. Examples of such baseline criteria include requirements for strength, stiffness, and fastener performance in prod- uct standards for sheathing and panel products used in shear walls and diaphragms. Resistance Factor: For LRFD, resistance factors are assigned to various wood properties with only one factor for each stress mode (i.e., bending, shear, compression, tension, and stability). Theoretically, the magnitude of a resistance factor is considered, in part, to reflect relative variability of material properties. However, for wood design in accordance with NDS, actual differences in product variability are already embedded in the reference design values. This is due to the fact that typical reference design values are based on a statistical estimate of a nearminimum value (5th percentile). The following resistance factors are used in SDPWS: a) shear wall and diaphragm in-plane shear for wind, ϕD = 0.80, and seismic ϕD = 0.50, b) sheathing out-of-plane bending ϕb = 0.85, and c) connections, ϕz=0.65. LRFD resistance factors have been determined by an ASTM consensus standard committee (16). Examination of ϕD=0.80 for wind and ϕD = 0.50 for seismic is addressed in ASTM D5457 (16) where calibration based on consideration of ASD and LRFD load factors for wind and seismic is used to reduce differences between ASD and LRFD designs for in-plane shear. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 67 C3 MEMBERS AND CONNECTIONS C3.1 Framing For wall stiffness, Polensek modeled 7 sets of 10 walls and compared the results. Polensek estimated bending stiffness Cr factors of 1.64 and 1.35 based on the maximum and average ratios of deflection, respectively, of the sheathed walls versus the same walls with bare studs. The Table 3.1.1.1 model estimated a bending stiffness Cr factor of 1.56 as a result of composite action and load-sharing. Wind loads on walls are created by variable peak pressures randomly occurring on the wall surfaces. ASCE 7 wind load provisions are based on estimates of these variable peak pressures as quasi-static uniform loads that vary based on the size and shape of the tributary area over which the “effective wind area” is averaged. Use of ASCE 7 uniform wind loads to estimate the distribution of peak pressures underestimates the modeled effects of load-sharing. In recognition of this effect, the bending stiffness Cr factor of 1.56 from the Table 3.1.1.1 model, which matched the bending strength Cr factor, was deemed appropriate. For design purposes, a slightly more conservative value of 1.5 was chosen to represent a modified 2x4 stud wall system sheathed with 3/8 in. wood structural panels and attached with 8d common nails rather than 6d box nails as follows: Polensek estimated a bending strength Cr factor of 1.56 for the simulated wall configuration. The Table 3.1.1.1 model also estimated a Cr factor of 1.56. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: MEMBERS AND CONNECTIONS C3.1.1.1 Wall Stud Bending Strength and Stiffness Design Value Increase: Wall studs sheathed on both sides are stronger and stiffer in flexure (i.e., wind loads applied perpendicular to the wall plane) than those in similar, unsheathed wall assemblies. The enhanced performance of these wood stud wall assemblies is recognized in wood design with the wall stud repetitive member factor, Cr, for bending strength and stiffness, which accounts for effects of partial composite action and load-sharing (1). This is in contrast to the repetitive member factor, Cr, in the NDS (6) which applies to a much broader range of repetitive member assembly applications and is limited to bending stress increases of no more than 15%. Wall stud repetitive member factors in SDPWS Table 3.1.1.1 are applicable for out-of-plane wind loads and increase the calculated strength and stiffness of pinned-end, bare studs when used in sheathed wood-frame wall assemblies constructed in accordance with 3.1.1.1. The factors in Table 3.1.1.1 were derived by modeling the effects of partial composite action and load-sharing. The model used to develop the repetitive member, Cr, factors in SDPWS Table 3.1.1.1 was initially compared against bending strength and stiffness estimated from a finite element wall model developed by Polensek (9). The baseline wall that was simulated by Polensek and used for verification of the Table 3.1.1.1 model was configured as follows: 68 COMMENTARY: MEMBERS AND CONNECTIONS For other stud depths, the wall stud repetitive member factor is taken as a function of the relative stiffness (EI) of the stud material. A repetitive member factor of 1.15 was assumed for a 2x12 stud in a wall system and Equation C3.1.1-1 was used to interpolate repetitive member factors for 2x6, 2x8, and 2x10 studs: Slight differences between calculated Cr values and those appearing in SDPWS Table 3.1.1.1 are due to rounding. C3.2 Sheathing Nominal uniform load capacities in SDPWS Tables 3.2.1A, 3.2.1B and 3.2.2 assume a two-span continuous condition for the sheathing across supports (e.g., studs, purlins, or other spaced supporting element for the sheathing). Out-of-plane sheathing capacities are often tabulated in other documents on the basis of a three-span continuous condition. Although the three-span continuous condition results in higher capacity, the more conservative two-span continuous condition was selected because this condition frequently exists at building end zones where the largest wind forces occur. Nominal uniform load capacities in SDPWS Tables 3.2.1A, 3.2.1B and 3.2.2 are based on strength calculations using established design strength properties for the sheathing (i.e., minimum of bending or shear capacity) and do not incorporate consideration of stiffness or deflection-based limits. Plywood load capacities are based on the minimum number of plies permitted for each panel grade in DOC PS 1, as noted in Footnote 5 in SDPWS Tables 3.2.1A and 3.2.2. Tables C3.2A1 and C3.2A2 provide out-of-plane bending capacities (FbS) and shear capacities (Fs(I b/Q)), respectively, for plywood based on bending and shear design values, and section properties from the Panel Design Specification (60). Bolded entries in Tables C3.2A1, C3.2A2, and C3.2E are associated with the minimum number of plies permitted for each panel grade in DOC PS 1 and are the basis of the tabulated nominal uniform load capacities in SDPWS Tables 3.2.1A, 3.2.1B, and 3.2.2. In SDPWS Table 3.2.2, dashes (i.e., “-”) identify configurations of sheathing type, span rating, support spacing and panel strength axis relative to supports that are not in accordance with industry recommendations for roof sheathing applications. For example, nominal uniform load capacities are not provided (e.g., shown as a dash) for OSB or plywood with 3/8 in. minimum nominal thickness, 24/0 span rating, and strength axis applied parallel to supports because it is not a recommended configuration for roof sheathing applications per the Panel Design Specification (60). Table C3.2A1 Plywood Sheathing Dry Design Bending Capacities 1. The bending capacity used in development of nominal uniform load capacities in SDPWS Table 3.2.1A and Table 3.2.2 are shown in bold. NA – Not applicable Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 69 Table C3.2A2 Plywood Sheathing Dry Design Shear Capacities in a Plane 1. The shear capacity used in development of nominal uniform load capacities in SDPWS Table 3.2.1A and Table 3.2.2 are shown in bold. NA – Not applicable Tables C3.2B1 and C3.2B2 provide out-of-plane bending and shear capacities, respectively for oriented strand board sheathing (OSB) based on bending design values, shear design values and section properties from the Panel Design Specification (60). Table C3.2B2 OSB Sheathing Dry Design Shear Capacities In The Plane C NA – Not applicable NA – Not applicable Table C3.2C provides out-of-plane bending capacities for cellulosic fiberboard sheathing based on minimum modulus of rupture criteria in ASTM C 208. Nominal uniform load capacities for cellulosic fiberboard sheathing in SDPWS Table 3.2.1B can be derived using the same procedure as described in Example C3.2.1. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: MEMBERS AND CONNECTIONS Table C3.2B1 OSB Sheathing Dry Design Bending Capacities 70 COMMENTARY: MEMBERS AND CONNECTIONS sheathing based on bending design values, shear design values and section properties from the Panel Design Specification (60). Table C3.2C Cellulosic Fiberboard Sheathing Design Bending Capacities Table C3.2D provides out-of-plane bending and shear capacities, respectively, for OSB Single Floor sheathing based on bending design values, shear design values and section properties from the Panel Design Specification (60). Table C3.2D OSB Single Floor Sheathing Dry Design Bending and Shear Capacities While they are not subjected to all the same durability requirements as wood structural panel sheathing products as part of their qualification, there are situations where designers elect to use Single Floor span-rated sheathing for roof applications. For this reason, Table 3.2.2 includes load capacities for Single Floor sheathing products installed in roof applications with the panel strength axis perpendicular to supports. Capacities for applications with the panel strength axis parallel to supports are not included because the tongue and groove edge joints and often “scant” face dimension necessitated by them are often not compatible with typical framing spacings. Table C3.2E provides out-of-plane bending and shear capacities, respectively, for Plywood Single Floor Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table C3.2E 71 Plywood Single Floor Sheathing Dry Design Bending and Shear Capacities 1. The bending and shear capacity used in development of nominal uniform load capacities in SDPWS Table 3.2.2 are shown in bold. NA – Not applicable Example C3.2.1 illustrates how values in SDPWS Table 3.2.1A were generated using plywood out-of-plane bending and shear values given in Tables C3.2A1 and C3.2A2. Although the following example is for SDPWS Table 3.2.1A, the same procedure can be used to generate values shown in SDPWS Table 3.2.1B. Determine the nominal uniform load capacity in SDPWS Table 3.2.1A Nominal Uniform Load Capacities (psf) for Wall Sheathing Resisting Out-of-Plane Wind Loads for the following conditions: Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: MEMBERS AND CONNECTIONS EXAMPLE C3.2.1 Determine the Nominal Uniform Load Capacity for Plywood Sheathing in SDPWS Table 3.2.1A C 72 COMMENTARY: MEMBERS AND CONNECTIONS C3.2.1 Wall Sheathing Where wood structural panel wall sheathing is used to provide the load path for wind uplift loads, the walls must be designed in accordance with 4.4. All other uplift force resisting systems must comply with 3.4.2. C3.3 Connections SDPWS 3.3 refers the user to the NDS (6) when designing connections to resist wind or seismic forces. In many cases, resistance to out-of-plane forces due to wind may be limited by connection capacity (withdrawal capacity of the connection) rather than out-of-plane bending or shear capacity of the panel. C3.4 Uplift Force Resisting Systems SDPWS 3.4 applies to all uplift force resisting systems. Where wood structural panels are used to provide load path for wind uplift loads, the provisions of 4.4 apply in lieu of 3.4.2. All other uplift force resisting systems, including systems that utilize metal connectors and continuous rod tie-downs consisting of threaded rods or cables, must comply with SDPWS 3.4.2. The design of such systems must be in accordance with accepted engineering practice and, for systems utilizing proprietary components, the manufacturer’s literature and code evaluation report, where applicable. The design must account for stresses induced into framing members and all other components and hardware within the system, as well as resulting deflections thereof. When detailing uplift force resisting systems, eccentricities in the uplift load path should be minimized Figure C3.4 or eliminated wherever possible (see Figure C3.4). In locations where this is not possible, the effect of eccentricities in the uplift load path must be considered. Such effects may include but are not limited to: moments induced into elements of the uplift force resisting system; torsion within, and rotation of, the top plate and other elements within the system; cross-grain bending and tension perpendicular-to-the-grain of wood members within the system. Eccentricities resulting in cross-grain bending or tension perpendicular-to-the-grain stresses within wood members should be avoided. Other factors that must be considered include deflection compatibility of the uplift force resisting system with the wall(s) in which it is used and dimensional changes in the wood elements due to moisture content fluctuations. Examples of Roof Uplift Connectors Appropriate uplift load path with uplift connector aligned with the wood structural panel sheathing providing wind uplift resistance. Inappropriate uplift load path prone to top plate rotation due to eccentric placement of uplift connector relative to the wood structural panel sheathing providing wind uplift resistance. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 73 C4 LATERAL FORCERESISTING SYSTEMS C4.1 General C4.1.1 Design Requirements General design requirements for lateral force-resisting systems are described in this section and are applicable to engineered structures and are in addition to those in ASCE 7 and the applicable building code. C4.1.2 Wood Lateral Force Resisting Systems in open front structures (C4.2.6) where forces are distributed by diaphragm rotation. C4.1.4 Shear Capacities Nominal unit shear capacities (see C2.2 Terminology) for diaphragms and shear walls require adjustment for ASD design and LRFD design. C4.1.3 Deformation Requirements Consideration of deformations (such as deformation of the overall structure, elements, connections, and systems within the structure) that can occur is necessary to maintain load path and ensure proper detailing. Special requirements are provided for wood members resisting forces from concrete and masonry (see C4.1.5) due to potentially large differences in stiffness and deflection limits for wood and concrete systems. Special requirements are also provided for sheathed wood-frame diaphragms Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.1.2.1 Sheathed Wood-frame Diaphragms and Shear Walls: Reference framing materials for sheathed wood-frame diaphragms and shear walls are sawn lumber or structural glued-laminated timber. Options are provided for the use of other framing materials (such as structural composite lumber), sheathing, or fasteners (for sheathed wood-frame diaphragms and shear walls) per either manufacturer’s instructions or evaluation reports, where approved (see 2.2 Terminology). Similarly, approved alternate procedures for designing wood-frame diaphragms and shear walls are permitted provided these procedures are in accordance with principles of engineering mechanics. C4.1.2.2 Cross-Laminated Timber (CLT) Diaphragms and Shear Walls: Provisions for CLT diaphragms and shear walls are provided in 4.5 and 4.6. Approved alternate design procedures for designing CLT diaphragms and shear walls are permitted provided these procedures are in accordance with principles of engineering mechanics. 74 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS For the same nominal unit shear capacity,νn, the specified ASD reduction factors (i.e., 2.0 for wind and 2.8 for seismic) result in design unit shear capacity for wind that is 1.4 times the design unit shear capacity for seismic. The resulting ASD design unit shear capacities for wind and seismic for wood structural panel shear walls match those from prior versions of SDPWS. C4.1.5 Wood Members and Systems Resisting Seismic Forces Contributed by Concrete and Masonry Walls The use of wood diaphragms with concrete or masonry walls is common practice. Story height and other limitations for wood members and wood systems resisting seismic forces from concrete or masonry walls are given to address deformation compatibility and are largely based on field observations following major seismic events. The phrase “other wood members and systems” in SDPWS 4.1.5 is intended to apply to all other wood members and systems including CLT shear walls and diaphragms. C4.1.5 Exception 1: Wood diaphragms (e.g., sheathed wood-frame diaphragms and CLT diaphragms) and horizontal trusses are specifically permitted to resist horizontal seismic forces from concrete or masonry walls. For construction over one story in height, wood diaphragms and horizontal trusses are permitted to resist horizontal seismic forces from concrete or masonry walls provided that the design of the diaphragm does not rely on torsional force distribution through the diaphragm. Primary considerations for this limitation are the flexibility of the wood diaphragm relative to concrete or masonry walls and the limited ability of concrete or masonry walls to tolerate out-of-plane wall displacements without failure. The term “horizontal trusses” refers to trusses that are oriented such that their top and bottom chords and web members are in a horizontal or near horizontal plane. A horizontal truss transmits lateral loads to shear walls in a manner similar to a floor or roof diaphragm. In this context, a horizontal truss is a bracing system capable of resisting horizontal seismic forces contributed by concrete or masonry walls. C4.1.5 Exception 2: Where wood structural panel sheathed shear walls are used to provide resistance to seismic forces contributed by concrete or masonry walls, design story drift (including combined deformations of both diaphragm and shear walls) is limited by deflection limits for concrete and masonry construction (5) (e.g., either 0.7% or 1.0% of the story height for masonry shear wall structures per ASCE 7). Strength level forces and appropriate deflection amplification factors, Cd, in accordance with ASCE 7 should be used when calculating design story drift, ∆. The intent of the design story drift limit is to limit failure of the masonry or concrete portions of the structure due to excessive deflection. C4.1.5.1 Anchorage of Concrete or Masonry Structural Walls to Diaphragms: For seismic design, the use of subdiaphragms as an analytical tool for transfer of wall anchorage forces was first introduced into the building code in the 1976 Uniform Building Code (UBC) (50) along with special detailing requirements to address observations of earthquake damage to buildings having plywood diaphragms and walls of structural concrete or masonry (46, 47, 48, and 49). The changes were introduced to prohibit designs that induced cross grain bending in wood members and relied on plywood sheathing in lieu of tension ties. The requirement for continuous ties, the subdiaphragm concept, and special detailing requirements in SDPWS are consistent with those found in ASCE 7 and prior editions of the building code where they originally appeared. Continuous ties spanning the full width of the diaphragm are required to be provided at wall anchorage points to the diaphragm so that the entire diaphragm width is engaged in resisting wall anchorage forces. Because wall anchors are often spaced as close as 4 feet on center, and because it is inefficient to provide continuous ties across the full diaphragm width at this close spacing, the subdiaphragm concept has been developed. This analytical tool enables a designer to detail connections along the continuous tie load paths within the diaphragm, without resorting to complex analysis which would be needed given the high level of redundancy within a sheathed wood-framed diaphragm. The subdiaphragm is a smaller diaphragm within the main diaphragm (Figure C4.1.5A) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC designed to ensure that the local wall anchorage forces can be safely transferred through the connections and members to the main diaphragm. Wall anchor forces are developed into the subdiaphragm, and continuous ties across the diaphragm are provided at each end of each subdiaphragm rather than at each wall anchor. Figure C4.1.5A illustrates subdiaphragms that anchor the west wall for seismic loading in the east-west direction. Similar subdiaphragms would be provided along the north and south walls for loading in the north-south direction and along the east wall. Use of subdiaphragms for purposes of distributing concrete or masonry structural wall anchorage forces may entail multiple subdiaphragms with subdiaphragm pan taken as the distance between continuous cross-ties of the main diaphragm, or use of a subdiaphragm that spans the full distance between side walls. In either case, subdiaphragms must meet all requirements for diaphragms and additionally are limited to a maximum aspect ratio of 2.5:1 consistent with the ASCE 7 limitation and intended to limit bending deformation and address deformation compatibility with the rest of the diaphragm. The 2.5:1 aspect ratio limit first appeared in the 1997 UBC. Although some designs have successfully used aspect ratios as high as 4, which is the limiting aspect ratio for blocked wood structural panel diaphragms, the aspect ratio limit of 2.5:1 is the maximum permitted and considered more suitable for a broad range of applications. C4.1.5.1.1 While direct loading of wood framing in cross grain bending or cross grain tension is not associated with an allowable design stress and should therefore be avoided as part of a designed load path, transfer of anchorage forces through wood framing subject to cross grain bending and cross grain tension are specifically prohibited. Details commonly employed for transfer of anchorage forces into the diaphragm use mechanical attachment between the wall anchor and wood framing oriented perpendicular to the wall (Figure C4.1.5B) avoiding direct loading of wood framing in cross grain bending. Figure C4.1.5B illustrates a typical wall anchor attached to a subdiaphragm roof purlin. Sheathing edge nailing into the purlin is provided as part of the load path between sheets of panel sheathing, but the sheathing is not considered part of the connection between the purlin and the ledger. Detailing of cross ties for tension relies on mechanical attachment of framing members (Figure C4.1.5C) avoiding direct loading of wood framing in cross-grain tension. Illustration of Subdiaphragm and Continuous Tie Concept (for west wall only) Note: For east west loading, subdiaphragm span is 40 ft between continuous ties and width is 40 ft The ratio of L/W = 40 ft/40 ft = 1.00 is less than 2.5:1 aspect ratio limit of 4.1.5.1). Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Figure C4.1.5A 75 76 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Figure C4.1.5B Example Details of Appropriate and Inappropriate Concrete and Masonry Wall Anchorage to Wood Diaphragms Figure C4.1.5C Example Details of Appropriate and Inappropriate Continuity Tie Details C4.1.5.1.2 Reliance on diaphragm sheathing to provide continuity between framing members is specifically prohibited (Figure C4.1.5C). The intended design approach is to preserve sheathing and sheathing nailing for in-plane shear loading and to reduce potential for concentration of deformation at sheathing joints between chords. The limitation is also intended to prohibit the design of wood sheathing to provide tension continuity for wall anchorage forces. C4.1.6 Wood Members and Systems Resisting Seismic Forces from Other Concrete and Masonry Walls Seismic forces from other concrete or masonry construction (i.e., other than walls) are permitted and must be accounted for in design. SDPWS 4.1.6 is not intended to restrict the use of concrete floors – including wood floors with concrete toppings as well as reinforced concrete slabs – or similar such elements in floor construc- tion. It is intended to clarify that, where such elements are present in combination with a wood system, the wood system must be designed to account for seismic forces generated by the additional mass of such elements. Design of wood members to support the additional mass of concrete and masonry elements must be in accordance with the NDS and required deflection limits as specified in concrete or masonry standards or model building codes (20). Masonry is defined as a built-up construction or combination of building units or materials of clay, shale, concrete, glass, gypsum, stone, or other approved units bonded together with or without mortar or grout or other accepted methods of joining. C4.1.7 Horizontal Distribution of Shear Seismic design requirements of ASCE 7 (5) require classification of diaphragms as semi-rigid, idealized as flexible, or idealized as rigid, and these terms are used in SDPWS 4.1.7.1, 4.1.7.2, and 4.1.7.3 to align with ASCE Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC and open front structures as depicted in SDPWS Figure 4A(d) analyzed as two separate cantilever diaphragms with diaphragm deflection based on the cantilever diaphragm deflection equation. Wood structural panel sheathed wood-frame diaphragms used with wood structural panel sheathed wood-frame shear walls will often meet the calculation requirement of the “idealized as rigid” condition; however, in most cases design professionals opt to use the “idealized as flexible” condition in sheathed wood-frame diaphragms when the prescriptive conditions of ASCE 7 are satisfied. Where this occurs, the design professional has the design option to use an idealized as flexible condition, to use an idealized as rigid condition, or to model the diaphragm as semi-rigid. When the sheathed woodframe shear walls are of approximately equivalent stiffnesses and are approximately evenly distributed in plan, the choice of modeling assumption will be inconsequential, however when this is not the case the design professional should exercise care in this choice. Where the ASCE 7 prescriptive condition allowing the idealized as flexible assumption is used for light frame construction with or without non-structural toppings of limited stiffness, it is required that the allowable story drift be satisfied for each line of vertical resisting elements. C4.1.8 Vertical Distribution of Seismic ForceResisting System (SFRS) Strength C4.1.8 Seismic design coefficients provided in ASCE 7 [5] for seismic-force-resisting systems (SFRS) composed of wood structural panel sheathed wood-frame shear walls have been rationalized using non-linear incremental dynamic analysis as described in FEMA P695 [68]. The models assumed structures with a tapered strength profile that approximated practical designs for lateral loads determined using the equivalent lateral force (ELF) procedure of ASCE 7 [5]. Subsequent studies using the P695 methodology for wood structural panel sheathed wood-frame shear wall structures have demonstrated that a tapered strength profile from small at the top story to large at the bottom story is generally beneficial to seismic performance (69, 70, 71). Discontinuities in this strength profile, particularly where the lower story is weaker than the story above (aka “weak story”), can adversely affect seismic performance [71]. The upper curve in Figure C4.1.8 (adapted from [71]) illustrates the adverse effect of a weak story on collapse probability for a building with the bottom floor optimized with regard to lateral strength. Points to the left of 1.0 on the horizontal axis represent the range of performance associated with Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS 7 terminology. The significance of “idealized” is to recognize that wood diaphragms always have some rigidity and are neither truly flexible nor truly rigid but can be idealized as such where certain conditions are met. An idealization is employed to simplify structural analysis for distribution of horizontal diaphragm shear loads. For diaphragms idealized as flexible, loads are distributed to vertical elements (e.g., shear walls) of the lateral force-resisting system (LFRS) of the story below according to tributary area, whereas for diaphragms idealized as rigid, loads are distributed according to the relative stiffnesses of the vertical elements of the LFRS of the story below. For diaphragms modeled as semi-rigid, the distribution of horizontal diaphragm shear loads to shear wall lines employs a more complex analysis. The use of semi-rigid diaphragm modeling for purposes of distribution of horizontal force is always permissible under ASCE 7. It is the method considered to most rationally account for actual distribution of horizontal diaphragm shear loads to vertical resisting elements; however, a semi-rigid diaphragm analysis requires significant calculation effort for all but the simplest box structures. An acceptable alternative to semi-rigid diaphragm analysis is the envelope analysis where distribution of horizontal diaphragm shear to each vertical resisting element is the larger of the shear forces resulting from analyses where the diaphragm is idealized as flexible and the diaphragm is idealized as rigid. While two separate analyses must be performed, one for the diaphragm idealized as flexible and one for the diaphragm idealized as rigid, the envelope analysis avoids calculation effort associated with distribution of horizontal diaphragm shear loads based on relative stiffness of the diaphragm and vertical resisting elements. The idealized as rigid diaphragm condition is permitted only where computed maximum in-plane deflection of the diaphragm itself under lateral load is less than or equal to two times the average deflection of adjoining vertical elements of the lateral force-resisting system of the associated story under equivalent tributary lateral load. This requirement is considered an appropriate corollary to the calculation-based “idealized as flexible” diaphragm condition of ASCE 7. The evaluation of deflections for permissible use of idealized as rigid will often utilize simplifying analysis assumptions generally consistent with the structural model to facilitate comparison of diaphragm in-plane deflection and deflection of adjoining elements. For example, a two-span diaphragm is commonly analyzed as two separate single-span diaphragms with diaphragm deflection based on the single span simply supported diaphragm deflection equation, 77 78 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS so called “regular” structural profiles, which do not have a weak story. Points on the curve to the right of 1.0 on the horizontal axis represent the performance of weak story profiles with the severity of the weak story increasing while moving to the right. A significant increase in collapse probability is observed for weak-story structures within the range permitted by ASCE 7. To reduce the potential for a degraded seismic response due to the presence of a weaker lower story, 4.1.8 prohibits the SFRS for a lower story in wood buildings from being weaker than the SFRS of the story above in seismic design categories D, E, and F, unless the lateral design strength of the lower story SFRS exceeds Vr(i+1)/ Vr(i) times the calculated lateral design load. This criterion is recognized to be more stringent than ASCE 7’s provisions for weak-story irregularities, which allow a lower story SFRS to be as much as 35% weaker than the upper story SFRS in seismic design category D and as much as 20% weaker than the upper story SFRS in seismic design categories E and F without requiring strengthening of the weaker lower story to exceed the design demand. The beneficial effect of strengthening the weaker lower story is illustrated in Figure C4.1.8 where the effect of increasing SRFS strength in the bottom story to exceed the design demand was investigated using the FEMA P695 methodology [70]. From Figure C4.1.8, it can be seen that the contours associated with Vr(1)=1.25 V(1) and Vr(1)=1.53 V(1) have reduced collapse probability over the range of 2nd story to 1st story strength ratios studied when compared to Vr(1)=1.0 V(1). A curve representing the effects of the strengthening required by 4.1.8 has been overlaid on the contours from [70]. The increase in strength of the weak story based on the requirement of 4.1.8 more than offsets the adverse effects of even extreme weak stories when compared to the performance of the “regular” structural profiles on the contour for Vr(1)=1.0 V(1) (i.e., for 2nd story to 1st story strength ratios below 1.0). Recognizing that the Vr(1)=1.0 V(1) contour for 2nd story to 1st story strength ratios below 1.0 represents the baseline performance of SFRS composed of wood structural panel sheathed wood-frame shear walls (68, 69, 71), it is observed that the required strengthening of 4.1.8 leads to equal or better predicted collapse performance than associated with numerical analysis from [68] that provides underlying support for the system’s seismic design coefficients. To satisfy the basic design requirement, the strength of all the SFRS for all stories must meet or exceed the design demand for that story (Equation C4.1-1). In addition, any story that is weaker than the story above must also satisfy SDPWS Inequality 4.1-1, which can be rearranged as follows to determine the required strength of a weak story: The story lateral strength used in ASCE 7 weak story irregularity requirements is associated with only that part of the structure that has been considered in the design to provide the required resistance to seismic forces (i.e., the (SFRS)). Resistance from other elements, such as finish materials, nonstructural partitions, and structural elements that are not designated as part of the SFRS, is neglected. While these non-SFRS elements may add initial stiffness and some degree of strength to the overall building system, the beneficial effects are often not well defined, may not significantly contribute to the overall strength at large displacements associated with a seismic failure limit state (81), and are conservatively ignored in the structural design for seismic force resistance. Other building elements that are not part of the designated SFRS system may adversely affect seismic performance by strengthening upper levels disproportionately to lower levels, creating an unintended weak-story effect. For example, buildings with open plans on the first level (e.g., parking or lobby space) and residential units at upper levels with more closely spaced walls that are not part of the SFRS may produce greater actual strength in the upper level. Analytical studies (see Figure C4.1.8, (71)) suggest that relatively minor levels of strengthening of a weak story to exceed design demand can effectively offset large discontinuities in strength profile where the upper story is significantly stronger than the lower story. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Figure C4.1.8 79 Trends in Collapse Probability based on Adjacent Story Strength Ratio C C4.1.10 Toe-Nailed Connections Boundary elements must be sized to transfer design tension and compression forces. Good construction practice and efficient design and detailing for boundary elements utilize framing members in the plane or tangent to the plane of the diaphragm or shear wall. Limits on use of toe-nailed connections in seismic design categories D, E, and F for transfer of seismic forces is consistent with building code requirements (2). Test data (12) suggests that the toe-nailed connection limit on a band joist to wall plate connection may be too restrictive; however, an appropriate alternative limit requires further study. Where blocking is used to transfer high seismic forces, toe-nailed connections can split the blocking or provide a weakened plane for splitting. C4.2 Sheathed Wood-Frame Diaphragms C4.2.1 Application Requirements C4.2.2 Diaphragm Aspect Ratios General requirements for sheathed wood-frame diaphragms include consideration of diaphragm strength and deflection. Maximum aspect ratios for floor and roof diaphragms (SDPWS Table 4.2.2) using wood structural panel or diagonal board sheathing are based on building code requirements (See SDPWS 4.2.5.1 for aspect ratio limits for cases where a torsional irregularity exists, for open front buildings, and cantilevered diaphragms). Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.1.9 Boundary Elements 80 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.2.3 Deflection The total mid-span deflection of a blocked, uniformly nailed (e.g., same panel edge nailing) wood structural panel diaphragm can be calculated by summing the effects of four sources of deflection as shown in Equation C4.2.3-1- bending deflection from bending chord deformation excluding slip (1st term), shear deflection from panel shear deformation (2nd term), shear deflection from panel nail slip (3rd term), and bending deflection due to chord splice slip (4th term): Constants appearing in Equations 4.2-1 through 4.23 are based on a derivation that considers diaphragm beam configuration and loading and the prescribed input values which include units of both feet and inches (see Example C4.2.3-4). Differences between equations account for differences in diaphragm beam configuration and loading. Distribution of shear forces among shear panels in a diaphragm is a function of the layup and nailing pattern of panels to framing. For this reason, shear deflection in a wood diaphragm is related to panel shear, panel layout, nailing pattern, and nail load-slip relationship. In SDPWS Equation 4.2-1, panel shear and nail slip have been combined as represented in the 2nd term to account for shear deformations. Equation C4.2.3-3 equates apparent shear stiffness, Ga, to nail slip and panel shear stiffness terms used in the four-term equation: SDPWS Equation 4.2-1 is a simplification of Equation C4.2.3-1, using three terms for calculation of the total mid-span diaphragm deflection: The calibration point for apparent shear stiffness, Ga, is at 1.4 times the ASD unit shear capacity for seismic (i.e., the LRFD unit shear capacity for seismic). This calibration point aligns with ASCE 7 requirements to evaluate seismic drift using strength level seismic forces and also matches the ASD unit shear capacity for wind. Calculated deflections, using either the 4-term (Equation C4.2.3-1) or 3-term equation (SDPWS Table 4.2.3 EquaCopyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC tion 4.2-1), are identical at the calibration point (see Figure C4.3.4B). From Figure C4.3.4B, it is also shown that for loads up to the calibration point, calculated deflections are larger for the 3-term equation. For unblocked wood structural panel diaphragms, tabulated values of Ga are based on limited test data for blocked and unblocked diaphragms (3, 4, and 11). For diaphragms of Case 1, reduced shear stiffness equal to 0.6Ga was used to derive tabulated Ga values. For unblocked diaphragms of Case 2, 3, 4, 5, and 6, reduced shear stiffness equal to 0.4Ga was used to derive tabulated Ga values. Examples C4.2.3-1 and C4.2.3-2 show derivations of Ga in SDPWS Tables 4.2A and 4.2B, respectively. A factor of 0.5 is provided in the diaphragm table footnotes to adjust tabulated Ga values (based on fabricated dry condition) to approximate Ga where “green” framing is used. This factor is based on analysis of apparent shear stiffness for wood structural panel shear wall and diaphragm construction where: 1) framing moisture content is greater than 19% at time of fabrication (green), and 2) framing moisture content is less than or equal to 19% in-service (dry). Comparison with Diaphragm Test Data Tests results for blocked and unblocked diaphragms (4) are compared to calculated deflections from SDPWS Equation 4.2-1 (C4.2.3-2) in Table C4.2.3E for diaphragms constructed as follows: Sheathing material = Sheathing Grade, 3/8in. nominal panel thickness Nail size = 8d common (2½ in. length, 0.131 in. shank diameter) Diaphragm length, L = 24 ft Diaphragm width, W = 24 ft Panel edge nail spacing = 6 in. Boundary nail spacing = 6 in. o.c. at boundary parallel to load (4 in. o.c. at boundary perpendicular to load for walls A and B) Calculated deflections at 1.4 x νs(ASD) closely match test data for blocked and unblocked diaphragms. In Table C4.2.3F, calculated deflections using SDPWS Equation 4.2-1 are compared to deflections from two tests of 20 ft x 60 ft (W = 20 ft, L = 60 ft) diaphragms (26) at 1.4 times the allowable seismic design value for a horizontally sheathed diaphragm and for a single diagonally sheathed lumber diaphragm. Calculated deflections include estimates of deflection due to bending, shear, and chord slip. For both diaphragms, calculated shear deformation accounted for nearly 85% of the total calculated mid-span deflection. Tested deflection for Diaphragm 4 is slightly greater than estimated by calculation and may be attributed to limited effectiveness of the diaphragm chord construction which utilized blocking to transfer forces to the double 2x6 top plate chord. For Diaphragm 2, chord construction utilized 2-2x10 band joists. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS The average ratio of “green” to “dry” for Ga across shear wall and diaphragm cells ranged from approximately 0.52 to 0.55. A rounded value of 0.5 results in slightly greater values of calculated deflection for “green” framing when compared to the more detailed 4-term deflection equations. Although based on nail slip relationships applicable to wood structural panel diaphragms, this reduction can also be extended to lumber sheathed diaphragm construction. 81 82 Table C4.2.3A SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Shear Stiffness, Gvtv (lb/in. of depth), for Wood Structural Panels 1. Sheathing grades used for calculating Ga values for diaphragm and shear wall tables. 2. Gvtv values for 3/8 in. panels with span rating of 24/0 used to estimate Ga values for 5/16 in. panels. 3. 5-ply applies to plywood with five or more layers. For 5-ply plywood with three layers, use Gvtv values for 4-ply panels. 4. See Table C4.2.3C for relationship between span rating and nominal panel thickness. Table C4.2.3B Shear Stiffness, Gvtv (lb/in. of depth), for Other Sheathing Materials Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table C4.2.3C 83 Relationships Between Span Rating and Nominal Thickness P = Predominant nominal thickness for each span rating. A = Alternative nominal thickness that may be available for each span rating. Check with suppliers regarding availability. Table C4.2.3D Fastener Slip, en (in.) C Table C4.2.3E Data Summary for Blocked and Unblocked Wood Structural Panel Diaphragms 1. Values of Ga for the blocked diaphragm case were taken from SDPWS Table 4.2A and multiplied by 1.2 (see footnote 3) because sheathing material was assumed to be comparable to 4/5-ply construction. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS 1. Slip values are based on plywood and OSB fastened to lumber with a specific gravity of 0.50 or greater. The slip shall be increased by 20 percent when plywood or OSB is not Structural I. Nail slip for common nails have been extended to galvanized box or galvanized casing nails of equivalent penny weight for purposes of calculating Ga. 2. The fastener slip relationships for wood structural panels in this table are approximate and based on limited evaluation of sheathing-to-framing connections with smooth shank common nails (3, 19). For purposes of calculating a design deflection for a diaphragm or shear wall, reasonable accuracy in calculated deflection from nail slip is considered to be achieved for the specified smooth shank nail across a range of design variations including side member thickness and panel type (plywood, OSB, or particleboard), nail bearing length in the framing member, framing member specific gravity, and moisture content of framing and sheathing. 84 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Table C4.2.3F Data Summary for Horizontal Lumber and Diagonal Lumber Sheathed Diaphragms 1. Calculated deflection equal to 0.81 in. includes estimates of deflection due to bending, shear, and chord slip (0.036 in. + 0.7 in. + 0.07 in. = 0.81 in.). Calculated deflection equal to 1.23 in. includes estimates of deflection due to bending, shear, and chord slip (0.13 in. + 1.05 in. + 0.05 in. = 1.23 in.). EXAMPLE C4.2.3-1 Derive Ga in SDPWS Table 4.2A EXAMPLE C4.2.3-2 Derive Ga in SDPWS Table 4.2B Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.2.3-3 Figure C4.2.3A 85 Calculate Mid-Span Diaphragm Deflection Diaphragm Dimensions and Shear and Moment Diagram C Diaphragm Chord, Double Top Plate with Two Joints in Upper Plate (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Figure C4.2.3B 86 EXAMPLE C4.2.3-3 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Calculate Mid-Span Diaphragm Deflection (continued) (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.2.3-3 Calculate Mid-Span Diaphragm Deflection (continued) EXAMPLE C4.2.3-4 Derivation of Constants for Equation 4.2-1 Mid-span Deflection of a Single Span Simply Supported Diaphragm with Uniformly Distributed Load 87 C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 88 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.2.4 Shear Capacities C4.2.4.1 See C4.1.4 for calculation of ASD unit shear capacity and LRFD factored unit shear resistance. C4.2.4.2 Nominal unit shear capacities provided in SDPWS Tables 4.2A, 4.2B, Table 4.2C are based on adjustment of allowable design values from building codes and industry reference documents (See C2.2) and are predicated on using products that comply with the product standards referenced in this Standard. The use of “minimum nominal panel thickness” in Tables 4.2A, 4.2B, and 4.2C column headings is to accommodate use of the tabulated nominal unit shear capacities for structural panels of greater thickness provided that nails with the prescribed dimensions are used and that bearing length of the nail into framing exceeds the prescribed minimum bearing length. This allowance recognizes that greater structural panel thickness will also develop the strength of the prescribed nailing upon which the nominal capacities are based. Nails are identified by name and dimensions (e.g., 8d common is 2.5 in. long by 0.131 in. diameter with a 0.281 in. diameter head) to reflect fasteners upon which tabulated nominal unit shear capacities are based. Nails of different type or dimensions are considered alternatives to the specified nails. For nails of matching diameter, but shorter in length than those specified in SDPWS, limited diaphragm test results (19) indicate load factors (i.e., ratio of ultimate shear load to ASD seismic design shear load) in excess of 3.0 where the SDPWS minimum required bearing lengths are maintained. In (19) test results are provided for both 10d duplex-head nails (2-3/4in. length x 0.148 in. shank diameter) and 8d duplex-head nails (2-1/4 in. length x 0.131 in. shank diameter), used to facilitate disassembly of the tested diaphragms, as well as plywood attached to framing with pneumatically driven 10d “short” nails (21/4 in. length x 0.148 in. shank diameter). For alternative designs where lengths shorter than specified are used, the effects of shorter nails should be carefully considered to ensure that sufficient capacity at the failure limit state is achieved given that failure may be governed by modes such as fastener withdrawal, framing splitting, or other conditions not directly incorporated into a typical lateral nail design calculation. C4.2.5 Torsional Requirements C4.2.5.1 Torsional Irregularity: Excessive torsional response of a structure can be a potential cause of failure. For structures identified as torsionally irregular, special requirements must be met to improve sheathed wood- frame diaphragm rigidity, including limits on diaphragm materials, diaphragm aspect ratio, and drift. The test for torsional irregularity is from ASCE 7 and is applicable for sheathed wood-frame diaphragms idealized as rigid or modeled as semi-rigid. For sheathed wood-frame diaphragms idealized as flexible, where distribution is by tributary area, requirements of this section are not applicable because such structures are not considered to be torsionally irregular under ASCE 7. C4.2.6 Open Front Structures (Cantilevered Diaphragms) C4.2.6.1 Open Front Structures (Cantilevered Diaphragms): While 4.2.6.1 introduces requirements specific to sheathed wood-frame diaphragms in open front structures, these are in addition to and not a replacement of general seismic design criteria of ASCE 7. A defining characteristic of an open front structure is the presence of a cantilevered diaphragm for transfer of forces to vertical elements of the lateral force-resisting system (LFRS). A structure with shear walls on three sides only (open front) is one simple form of an open front structure. Open front structures rely on diaphragm rigidity for transfer of forces through diaphragm rotation and are considered to be more vulnerable to torsional response than other box type structure configurations due to reliance on the diaphragm for torsional force distribution to elements that are not optimally located at diaphragm edges. As a result, open front structure provisions require limitations on seismic drift and building configuration similar to provisions for torsionally irregular structures that are not open front for the purpose of reducing the likelihood of an unacceptable torsional response of such structures. For loading parallel to the open side, the requirement to check drift at building edges applies regardless of the analysis method used (e.g., diaphragm idealized as rigid, semi-rigid analysis, or envelope analysis) and regardless of whether the test for torsional irregularity indicates presence of a torsional irregularity. The required use of either idealized as rigid analysis or semi-rigid analysis for loading parallel to the open front is due to the reliance on diaphragm rigidity for transfer of torsional forces. Required use of these analysis methods is also intended to ensure that torsional irregularity and associated requirements for torsion in ASCE 7 are invoked as applicable for this structure type. There are no specific requirements for diaphragm rigidity assumptions for loading perpendicular to the open front. For example, it is not required for diaphragms to be modeled as semi-rigid or idealized as rigid for load- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC ing perpendicular to the open front. Open front building plans often have regular placement of walls aligned perpendicular to the open front that is conducive to the idealized as flexible analysis for loading perpendicular to the open side. Example C4.2.6.1-1 illustrates components of deflection contributing to seismic drift at edges for a simple cantilevered sheathed wood-frame diaphragm structure and Example C4.2.6.1-2 illustrates a condensed numeric example. The cantilevered diaphragm structure depicted in Figure C4.2.6A consists of a cantilevered diaphragm of length Lʹ, transverse resisting shear walls of length Lʹ, and longitudinal shear wall of length Wʹ. The seismic force is uniformly distributed over cantilever diaphragm length, Lʹ. Center of rigidity, CR, is located at the midpoint of the longitudinal shear wall and center of mass, CM, is located at the geometric center of diaphragm dimensions LʹxWʹ. Components of diaphragm deflection 89 contributing to seismic drift at edges consist of translation, rotation, and diaphragm shear including flexural deformations as depicted in Figure C4.2.5B. An important aspect of the example is that flexural and shear deformations of the diaphragm are to be included in the required check of drift at diaphragm edges. This deformation of the diaphragm is to be included whether the diaphragm is idealized as rigid or modeled as semi-rigid. The exception in SDPWS 4.2.6.1 excludes relatively small diaphragm cantilevers from open front criteria. Small diaphragm cantilevers, with Lʹ of six feet or less, are often present and the complexity and limitations associated with open front criteria was not judged to be warranted. While such small diaphragm cantilevers are exempt from open front requirements of 4.2.6.1, general seismic design criteria of ASCE 7 remain applicable as well as provisions of 4.2.5.1 for cases where a torsional irregularity is present. C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 90 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS EXAMPLE C4.2.6.1-1 Illustrate Components of Deflection Contributing to Seismic Story Drift at Edges for a Simple Cantilevered Sheathed Wood-Frame Diaphragm Structure Figure C4.2.6A Simple Cantilevered Sheathed Wood-Frame Diaphragm Structure Figure C4.2.6B Components of Diaphragm Deflection Contributing to Seismic Story Drift at Edges Discussion: Components of diaphragm deflection contributing to story drift consist of translation, rotation, and diaphragm shear and flexural deformations as depicted in Figure C4.2.6B. • The translation component of deflection is from deflection of the longitudinal shear wall, W', under the applied shear loading • The rotation component of deflection is from deflection of transverse shear walls, L', under torsional moment caused by eccentric loading. • The diaphragm shear and flexure component of deflection is from the diaphragm itself under the assumed distributed shear loading and includes inplane shear and flexural deflection of the diaphragm. Consistent with ASCE 7 requirements, when checking design story drift at edges against ASCE 7 story drift limits, it is necessary to multiply deflection determined using strength level forces by the applicable deflection amplification factor. For wood structural panel sheathed wood-frame shear walls in a bearing wall system, the applicable ASCE 7 deflection amplification factor, Cd, is equal to 4. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.2.6.1-2 91 Numeric Example for Deflections Contributing to Seismic Story Drift at Edges for a Simple Cantilevered Sheathed Wood-Frame Diaphragm Structure Calculate the seismic story drift at the edge of the simple cantilever diaphragm configuration depicted in Figure C4.2.6A with Lʹ = 32 ft, Wʹ=136 ft. The basic diaphragm configuration is associated with the cantilever portion of the 2nd floor diaphragm of a 4-story building. Shear wall deflection in first story wood structural panel shear walls associated with translation and rotation components of deflection at the diaphragm edge (see Figure C4.2.6A) is given. The diaphragm meets requirements to be idealized as rigid in SDPWS 4.1.7 and for diaphragms in open front structures in SDPWS 4.2.6. The blocked diaphragm consists of 19/32 in. plywood sheathing nailed with 10d common nails and has apparent shear stiffness, Ga = 17 kips/in. Diaphragm deflection is calculated in accordance with the following: C Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Total deflection at the diaphragm edge, which includes translation and rotation components (see Figure C4.2.6B for illustration) at strength level loading: For this example, the ASCE 7 system overstrength factor for wood structural panel sheathed wood-frame shear wall system is used to approximate the amplified deflection of the diaphragm for induced forces which may be more than associated with the diaphragm design loads. For 10 ft story height, and 2.5% drift limit, maximum permissible drift is 3.0 inches. For this example, 2.96 inches < 3.0 inches, which satisfies the seismic drift limit at edge per SDPWS 4.2.6. C4.2.6.2 Simplification of open front criteria was judged appropriate for relatively small one-story structures where Lʹ is not more than 25 feet and Lʹ/Wʹ is less than or equal to 1:1. In such structures, the diaphragm is permitted to be idealized as rigid for distribution of horizontal shear forces regardless of whether the diaphragm meets the calculation-based definition of idealized as rigid in SDPWS 4.1.7. Other requirements for cantilever diaphragms remain applicable including provisions of 4.2.5.1 for cases where a torsional irregularity is present as well as general seismic design criteria of ASCE 7. 92 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.2.7 Construction Requirements C4.2.7.1 Framing Requirements: The transfer of forces into and out of diaphragms is required for a continuous load path. Boundary elements must be sized and connected to the diaphragm to ensure force transfer. This section provides basic framing requirements for boundary elements in diaphragms. Good construction practice and efficient design and detailing for boundary elements utilize framing members in the plane of the diaphragm or tangent to the plane of the diaphragm (See C4.1.9). Where splices occur in boundary elements, transfer of force between boundary elements should be through the addition of framing members or metal connectors. The use of diaphragm sheathing to splice boundary elements is not permitted. C4.2.7.2 Sheathing: Sheathing types for diaphragms included in SDPWS Table 4.2A and Table 4.2B are categorized in terms of the following wood structural panel grades (i.e., structural use panel grades) as defined in PS1 and PS2: Structural I, Sheathing, and Single-Floor. All of these panels use exterior adhesives and are rated for either Exposure 1 or Exterior use. Sheathing panels rated for subfloor, roof, and wall use are usually unsanded Structural I sheathing panels are used where the greatest available shear and cross-panel strength properties are required. Single-Floor sheathing panels are rated for use as a combination of subfloor and underlayment, usually with tongue and groove edges, and have sanded or touch sanded faces. SDPWS Table 4.2A and Table 4.2B are applicable to both oriented strand board (OSB) and plywood. While strength properties between equivalent grades and thicknesses of OSB and plywood are the same, shear stiffness of OSB is greater than that of plywood of equivalent grade and thickness. Tabulated plywood Ga values are based on 3-ply plywood. Separate values of Ga for 4-ply and 5-ply plywood, panels were calculated and ratios of these values to Ga based on 3-ply were shown to be in the order of 1.09 to 1.22 for shear walls and 1.04 to 1.16 for diaphragms. A single Ga multiplier of 1.2 that is intended to be applied to the tabulated 3-ply plywood Ga value was chosen for 4-ply, 5-ply, and composite panels in table footnotes. This option was considered preferable to tabulating Ga values for 3-ply, 4-ply, 5-ply, and composite panels separately. The term “composite panel”, as used in footnote 3 in SDPWS Tables 4.2A and 4.2B, refers to a panel containing a combination of veneer and other wood-based material that meets performance criteria for its type in DOC PS1 or PS2 and is not intended to describe OSB, which has its own tabulated values of Ga. C4.2.7.3 Fasteners: Adhesive attachment in diaphragms can only be used in combination with fasteners. Details on type, size, and spacing of mechanical fasteners used for typical floor, roof, and ceiling diaphragm assemblies are provided in SDPWS 4.2.8 Sheathed WoodFrame Diaphragm Assemblies and in Tables 4.2A, 4.2B, 4.2C, and 4.2D. C4.2.8 Sheathed Wood-Frame Diaphragm Assemblies C4.2.8.1 Wood Structural Panel Diaphragms: Where wood structural panel sheathing is applied to sawn lumber planking or laminated decking – such as in a retrofit or new construction where wood structural panel diaphragm capacities are desired – additional fastening, aspect ratio limits, and other requirements are prescribed to develop diaphragm capacity and transfer forces to boundary elements. C4.2.8.1.1 Blocked Diaphragms: Standard construction of wood structural panel diaphragms requires use of full size sheets, not less than 4 ft x 8 ft except at changes in framing where smaller pieces may be needed. Panel edges must be supported by and fastened to framing members or blocking. For panel widths less than 24 in. capacities for bending and axial tension should be reduced in accordance with applicable panel size adjustment factors (panel width adjustment factors are described in the Commentary to the National Design Specification for Wood Construction (6)). Apparent shear stiffness values provided in SDPWS Table 4.2A are based on standard assumptions for panel shear stiffness for oriented strand board (OSB), plywood, and nail load slip (see C4.2.2). In accordance with SDPWS Table 4.2A, nail spacing requirements for a given unit shear capacity vary by the direction of continuous panel joints with respect to a) the loading direction and b) direction of framing members. The six possible cases are depicted in SDPWS Table 4.2A and are grouped as Cases 1 and 3, Cases 2 and 4, and Cases 5 and 6 to show that diaphragm resistance is independent of panel orientation. C4.2.8.1.1(3) For closely spaced nails, staggered nail placement at each panel edge is intended to minimize splitting in the framing member (see Figure C4.2.8A). The staggering of fasteners also increases distance from the nail to the edge of the sheathing which has been observed to improve strength in shear testing of nailed structural panels as opposed to placing all sheathing fasteners at the minimum panel edge distance. The amount of stagger is not prescribed because even a slight stagger, Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC such as 1/8 in. meets the intent of the requirement. The minimum width of nailed face of framing and blocking is 2 in. nominal. For certain closely spaced nailing configurations at adjoining panel edges, the minimum width of nailed face of framing and blocking is increased to 3 in. nominal (see Figure C4.2.8A). In SDPWS 4.2.8.1.1(3)a, the minimum width of nailed face is 3in. nominal at continuous adjoining panel edges where Table 4.2A prescribes nail spacing of 2-1/2 in. on center or less (i.e., 2-1/2 in. and 2 in. nail spacing columns of Table 4.2A). In SDPWS 4.2.8.1.1(3)b, the minimum width of nailed face is 3 in. nominal at adjoining panel edges where Table 4.2A prescribes 10d common nails and a nail spacing of 3in. on center or less. The excepFigure C4.2.8A 93 tion to SDPWS 4.2.8.1.1(3)b allows the minimum width of nailed face to be 2 in. nominal at non-continuous adjoining panel edges provided that the nominal unit shear capacity for the diaphragm is limited to the tabulated values in Table 4.2A for the case where minimum 2 in. nominal width of nailed face at adjoining panel edges and boundaries is specified. For Cases 5 and 6, that have continuous adjoining panel edges perpendicular and parallel to framing, minimum 3 in. nominal width of nailed face is required for all framing and blocking when nail spacings are equal to or less than those prescribed in SDPWS 4.2.8.1(3a) and SDPWS 4.2.8.1(3b) (see SDPWS Figure 4B). Staggering of Nails at Panel Edges of Blocked Diaphragms C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 94 Figure C4.2.8B SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Examples of Minimum Nominal Width of Nailed Face of Framing or Blocking at Adjoining Panel Edge Locations where Nails are Closely Spaced (SDPWS 4.2.8.1.1(3a) and 4.2.8.1.1(3b)) C4.2.8.1.2 High Load Blocked Diaphragms: Wood structural panel blocked diaphragms with multiple rows of 10d common nails are also referred to as “high load diaphragms”. Tests of nailed plywood-lumber joints (32) closely match recommended nailing patterns and verify calculations of unit shear associated with multiple rows of 10d common nails in Table 4.2B. The high load diaphragm table specifies use of framing with a minimum 3in. or 4in. nominal width for the nailed face and a minimum 3in. nominal depth at adjoining panel edges and boundaries to provide adequate edge distance and penetration depth for multiple rows of 10d common nails at these locations (see SDPWS Figure 4B). These requirements are important to limit splitting associated with the specified nailing required for high load blocked diaphragms. Fastener spacing per line is listed in Table 4.2B as well as number of lines of fasteners. Nails should not be located closer than 3/8in. from panel edges. Where the nominal width of nailed face and nail schedule permits greater panel edge distance, a 1/2in. minimum distance from adjoining panel edges is specified. Apparent shear stiffness values are tabulated for each combination of nailing and sheathing thickness consistent with the format of tabulating apparent shear stiffness, Ga, for typical blocked and unblocked diaphragms. SDPWS Figure 4B depicts a 1/8 in. minimum gap between adjoining panel edges to allow for dimensional change of the panel. In general, 4 ft x 8 ft panels will increase slightly in dimension due to increased moisture content in-use. relative to moisture content immediately following manufacture. In some cases, due to exposure conditions following manufacture, the expected increase in panel dimensions is smaller than anticipated by the 1/8in. minimum gap and therefore the gap at time of installation may be less than 1/8 in. minimum. Dimensional change and recommendations for installation can vary by product and manufacturer, therefore recommendations of the manufacturer for the specific product should be followed. C4.2.8.1.3 Unblocked Diaphragms: Standard construction of unblocked wood structural panel diaphragms requires use of full-size sheets, not less than 4 ft x 8 ft except at changes in framing where smaller sections may be needed. Unblocked panel widths are limited to 24 in. or wider. Where smaller widths are used, panel edges must be supported by and fastened to framing members or blocking. The 24 in. width limit coincides with the minimum width where panel strength capacities for bending and axial tension are applicable (6). For widths less than 24 in. capacities for bending and axial tension should be reduced in accordance with applicable panel size factors, Cs, in the National Design Specification (NDS) for Wood Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Construction (6). Apparent shear stiffness values provided in SDPWS Table 4.2C are based on standard assumptions for panel shear stiffness for oriented strand board (OSB), plywood, and nail load slip (see C4.2.3). C4.2.8.2 Diaphragms Diagonally Sheathed with Single Layer of Lumber: Single diagonally-sheathed lumber diaphragms have comparable strength and stiffness to many wood structural panel diaphragm systems. Apparent shear stiffness in SDPWS Table 4.2D is based on assumptions of relative stiffness and nail slip (see C4.2.3). C4.2.8.3 Diaphragms Diagonally Sheathed with Double-Layer of Lumber: Double diagonally sheathed lumber diaphragms have comparable strength and stiffness to many wood structural panel diaphragm systems. Apparent shear stiffness in SDPWS Table 4.2D is based 95 on assumptions of relative stiffness and nail slip (see C4.2.3). C4.2.8.4 Diaphragms Horizontally Sheathed with Single-Layer of Lumber: Horizontally sheathed lumber diaphragms have low strength and stiffness when compared to those provided by wood structural panel diaphragms and diagonally sheathed lumber diaphragms of the same overall dimensions. In new and existing construction, added strength and stiffness can be developed through attachment of wood structural panels over horizontally sheathed lumber diaphragms (see SDPWS 4.2.8.1). Apparent shear stiffness in SDPWS Table 4.2D is based on assumptions of relative stiffness and nail slip (see C4.2.3). C4.3 Sheathed Wood-Frame Shear Walls C4.3.1 Application Requirements C4.3.2 Shear Wall Types SDPWS identifies sheathed wood-frame shear walls as one of the following types: 1. Individual Full-Height Wall Segments (i.e., no openings within an individual full-height segment); 2. Force-transfer Around Openings (FTAO) Shear Walls (i.e., with openings, but framing members, blocking, and connections around openings are designed for force-transfer); C4.3.2.1 Individual Full-Height Wall Segments: Shear wall design provisions for individual full-height wall segments, designed as shear walls without openings, are applicable to walls designed and constructed in accordance with provisions as outlined in SDPWS 4.3.2.1. C4.3.2.2 Force-transfer Around Openings (FTAO) Shear Walls: FTAO shear wall design provisions are applicable to walls designed and constructed in accordance with provisions as outlined in SDPWS 4.3.2.2. Design of FTAO shear walls is required to be in accordance with a rational analysis as described in SDPWS 4.3.2.2. Under this approach, it is the responsibility of the designer to establish detailing (e.g., size and length of straps above and below openings) to ensure appropriateness of the assumptions in the analysis as shown in Figure C4.3.2.2. Collectors for the transfer of shear force between the FTAO wall and diaphragm are required for the full length of the wall and will often extend beyond the FTAO wall (Figure C4.3.2.2). Limited testing has been conducted to evaluate several rational analysis methods commonly referred to as the drag strut, cantilever beam, and Diekmann methods (53). The mathematical development of the drag strut method and cantilever beam method (54) are based on assumptions for shear transfer above and below the openings and development of the Diekmann method (55) is based on resolving internal forces assuming rigid body behavior. Another rational analysis meth- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS General requirements for sheathed wood-frame shear walls include consideration of shear wall deflection (discussed in 4.3.2) and strength (discussed in 4.3.3), and are predicated on using products that comply with the product standards referenced in this Standard. Shear wall performance has been evaluated by monotonic and cyclic testing and references to test reports are provided throughout the Commentary. Cyclic testing, in accordance with ASTM E 2126 (34) Method C is commonly used to study seismic performance of sheathed wood-frame shear wall behavior (14, 22, 25, 29, and 33). The cyclic loading protocol associated with ASTM E 2126 Method C is also known as the “CUREE” protocol (37). Reports containing results (15, 28, and 36) from other cyclic protocol, such as ASTM E 2126 Method A and Method B, commonly referred to as the “SEAoSC” and “ISO” protocols respectively, are also included as references for seismic design provisions of the SDPWS. 3. Perforated Shear Walls (i.e., with openings, but rather than design for force-transfer around openings, reduced shear strength is used based on size of openings). 96 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS od, referred to as the SEAOC-Thompson method (56) is commonly employed for the design of FTAO shear walls. Limited evaluation of the SEAOC-Thompson method has shown that the results for strap force predictions are similar to those of the Diekmann method for several tested wall configurations (46). Figure C4.3.2.2 FTAO Shear Wall Collector C4.3.2.3 Perforated Shear Walls: Perforated shear wall design provisions are applicable to walls with wood structural panel sheathing, designed and constructed in accordance with provisions as outlined in SDPWS 4.3.2.3. In SDPWS 4.3.2.3(2), a perforated shear wall segment is required at each end of a perforated shear wall. Perforated shear wall length is the distance between perforated shear wall ends where hold-downs or other overturning restraints are provided. The single-side nominal unit shear capacity limit of 2,435 plf is based on tests utilizing 10d common nails at 2 in. o.c. at panel edges on one side (45). For double-sided walls, the nominal unit shear capacity limit is not increased (i.e., the combined nominal unit shear capacity for walls sheathed on two sides shall not exceed 2,435 plf) because the tested walls represent the maximum unit shear capacity for which tests are available. C4.3.3 Shear Wall Aspect Ratios and Capacity Adjustments wind or seismic forces. The factor accounts for observed reduction in peak unit shear capacity from testing (29) of high-aspect shear walls and varies from 1.0 for 1:1 aspect ratio shear walls to 0.78 for 3.5:1 aspect ratio shear walls. Reductions in shear wall unit shear capacity are addressed with aspect ratio factors in 4.3.3.2; however, the loss of stiffness as aspect ratio increases can be large and affect usable design unit shear capacity. For example, due to reduced stiffness, a high aspect ratio shear wall may reach a deflection limit or drift limit prior to developing even the reduced unit shear capacity associated with the high aspect ratio shear wall based on unit shear capacity reductions of 4.3.3.2. In addition, where a high aspect ratio shear wall is in line with a low aspect ratio shear wall, development of the full design unit shear capacity of the low aspect ratio shear wall is likely to occur at relatively small deflections where only a fraction of the full design unit shear capacity of the high aspect ratio shear wall is developed. Requirements of 4.3.3.2 address the shear wall strength limit state while those in 4.3.5.5 address deflection compatibility between shear walls in a line. Both strength and deflection compatibility criteria must be addressed as part of a design. For example, unit shear capacity associated with each shear wall must satisfy deflection compatibility criteria as well as criteria of 4.3.3.2 establishing unit shear capacity based on shear wall aspect ratio. The smaller of the design unit shear capacities associated with requirements of 4.3.3.2 and 4.3.5.5 is used as the controlling design unit shear capacity for each shear wall (see Example C4.3.5.5.1-1 and C4.3.5.5.1-2). C4.3.4 Deflection The deflection of a shear wall can be calculated by summing the effects of four sources of deflection as shown in Equation C4.3.4-1- bending deflection (1st term), shear deflection from panel shear deformation (2nd term), shear deflection from nail slip (3rd term), and deflection due to wall anchorage deformation (4th term): C4.3.3.2 The aspect ratio factor, 1.25 - 0.125h/b, is applicable to blocked wood structural panel shear walls designed to resist either wind or seismic forces. The factor ranges in value from 1.0 for 2:1 aspect ratio shear walls to 0.81 for 3.5:1 aspect ratio shear walls and accounts for reduced unit shear capacity observed from monotonic and cyclic tests of high aspect ratio shear walls relative to lower aspect ratio shear walls (35, 36). The aspect ratio factor, 1.09 - 0.09 h/b, is applicable to structural fiberboard shear walls designed to resist either Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC SDPWS Equation 4.3-1 is a simplification of Equation C4.3.4-1, using only three terms for calculation of shear wall deflection 97 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Constants appearing in Equation 4.3-1 are based on a derivation that considers a cantilever beam with concentrated load at the free end and the prescribed input values which include units of both feet and inches (see Example C4.3.4-2). Typical application of Equation 4.3-1 for sheathed wood-frame shear walls in multi-story platform construction (72) assumes that rotational effects do not accumulate from story to story. Such an assumption has been considered appropriate in view of actual features of typical platform construction that limit the ability of stacked shear walls in multi-story platform construction from accumulating rotational deformations. While beam theory of idealized elements suggest that an added source of rotational deformation may occur in stacked shear walls (73) the increase in calculated shear wall deflection relative to typical practice is based on assumptions (wall stacks in isolation) that are seldom present in typical construction. While it is theoretically conservative to include rotational effects for estimating seismic drift, it is recognized that such an approach may also incorrectly suggest longer building periods than would result from application of typical assumptions for platform construction, and these longer periods have not been observed in shake table testing. In SDPWS Equation 4.3-1, deflection due to panel shear and nail slip are accounted for by a single apparent shear stiffness term, Ga. Calculated deflection, using either the 4-term (Equation C4.3.4-1) or 3-term equation (SDPWS Equation 4.3-1 and Equation C4.3.4-2), are identical at 1.4 times the allowable shear value for seismic (see Figure C4.3.4) to facilitate use for checking seismic drift at strength level forces in accordance with ASCE 7. This calibration point also coincides with ASD unit shear capacities for wind and is also suitable for calculating deflections from wind load induced unit shears up to the ASD unit shear capacity. Below the calibration point, calculation using the 3-term equation overestimates deflection relative to the 4-term equation but such overestimations are generally negligible for design purposes. These small differences, however, can influence load distribution assumptions based on relative stiffness if both deflection calculation methods are used in a design. For consistency and to minimize calculation-based differences, either the 4-term equation or 3-term equation should be used for all shear walls in a line. 98 Figure C4.3.4 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Comparison of 4-Term and 3-Term Deflection Equations Each term of the 3-term deflection equation accounts for independent deflection components that contribute to overall shear wall deflection. For example, apparent shear stiffness is intended to represent only the shear component of deflection and does not also attempt to account for bending or wall anchorage slip. In many cases, such as for gypsum wallboard shear walls and fiberboard shear walls, results from prior testing (17 and 23) used to verify apparent shear stiffness estimates were based on ASTM E 72 (41) where effects of bending and wall anchorage slip are minimized due to the presence of metal hold-down rods in the standard test set-up. The relative contribution of each of the deflection components will vary by aspect ratio of the shear wall. For other than narrow (high aspect ratio) shear walls, deformation due to shear deformation (combined effect of nail slip and panel shear deformation) is the largest component of overall shear wall deflection. The effect of wall anchorage slip becomes more significant as the aspect ratio increases and as the imposed stress approaches the published compression perpendicular to grain capacity of the plate materials. SDPWS requires an anchoring device (see SDPWS 4.3.6.4.2) at each end of the shear wall where dead load stabilizing moment is not sufficient to prevent uplift due to overturning. For standard anchoring devices (hold-downs), manufacturers’ literature typically includes ASD capacity (based on short-term load duration for wind and seismic), and corresponding deflection of the device at ASD levels. Deflection of the device at strength level forces may also be obtained from manufacturers’ literature. Reported deflection may or may not include total deflection of the device relative to a wood post and elongation of the hold-down bolt or strap in tension. All sources of vertical elongation of the anchoring device, such as slip in the connection of the device to the wood post, elongation of the hold-down rod, and slack in the anchorage strap, should be considered when estimating the Δa term in SDPWS Equation 4.3-1. Estimates of Δa at strength level forces are needed when evaluating drift in accordance with ASCE 7 is required. The definition of Δa includes potential sources of compressive deformation in addition to vertical deformation of the wall overturning anchorage system. While reasonable agreement between the calculated and tested deflection has been demonstrated for shear walls with 1:1 and lower aspect ratios without considering small compression deformations, compression deformations can be a significant contributor to total shear wall deflection where a shear wall aspect ratio is high (80) (see Example C4.3.4-2). Recognizing its small effect on low aspect ratio shear wall deflections as well as the complexity of accounting for compression deformations, a designer will typically employ simplifying assumptions in the analysis to determine when to explicitly consider compression deformations as part of the total shear wall deflection calculation. In shear wall table footnotes (SDPWS Table 4.3A), a factor of 0.5 is provided to adjust tabulated Ga values (based on fabricated dry condition) to approximate Ga where “green” framing is used. This factor is based on analysis of apparent shear stiffness for wood structural panel shear wall and diaphragm construction where: 1. framing moisture content is greater than 19% at time of fabrication (green), and 2. framing moisture content is less than or equal to 19% in-service (dry). The average ratio of “green” to “dry” for Ga across shear wall and diaphragm cells ranged from approximately 0.52 to 0.55. A rounded value of 0.5 results in slightly greater values of calculated deflection for “green” framing when compared to the more detailed 4-term deflection equations. Although based on nail slip relationships applicable to wood structural panel shear walls, this reduction is also extended to other shear wall types where green framing lumber is used. In Table C4.3.4A, calculated deflections using SDPWS Equation 4.3-1 are compared to deflections from tests for shear walls with fiberboard, gypsum board, and lumber sheathing, where the unit shear is 1.4 times the ASD seismic unit shear value for fiberboard and lumber sheathing. For lumber sheathing, calculated stiffness is Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC underestimated when compared to test-based stiffness values. However, the lower stated stiffness for horizontal and diagonal lumber sheathing is considered to better reflect stiffness after lumber sheathing dries in service. Early studies (24) suggest that stiffness after drying in service may be 1/2 of that during tests where friction between boards in lumber sheathed assemblies is a significant factor. C4.3.4.2 Deflection of Perforated Shear Walls: The deflection of a perforated shear wall can be calculated using SDPWS Equation 4.3-1 using substitution rules as follows to account for reduced stiffness of full-height perforated shear wall segments: ν = maximum induced unit shear force (plf) in a perforated shear wall, νmax, per SDPWS Equation 4.3-9 b = sum of perforated shear wall segment lengths (full-height), Σbi, ft For most cases, values of C(ub) are less than 1.0, so induced unit shear is amplified by 1/C(ub) resulting in larger deflection for the less stiff unblocked shear wall relative to the blocked shear wall reference condition. The C(ub) factor can also be viewed as a stiffness reduction factor. For example, simplification of the shear term in Equation C4.3.4.3-1 yields: 4.3.4.4 Deflection of Structural Fiberboard Shear Walls: The calculated deflection of shear walls sheathed with structural fiberboard having an aspect ratio greater than 1.0 is underestimated when compared to results from cyclic testing (29). An adjustment factor equal to (h/b)1/2 is therefore used to account for the increased deflection of structural fiberboard shear walls having aspect ratios greater than 1.0. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.3.4.3 Deflection of Unblocked Wood Structural Panel Shear Walls: Unblocked shear walls exhibit loaddeflection behavior similar to that of a blocked shear wall but with reduced values of strength and stiffness. The unblocked shear wall adjustment factor, C (ub), accounts for the effect of unblocked joints on strength and stiffness. Nominal unit shear capacity of a blocked wood structural panel shear wall with stud spacing of 24 in. o.c. and panel edge nail spacing of 6 in. o.c. is the reference condition for determination of unblocked shear wall nominal unit shear capacity (e.g., νn(ub) = νn(b) C(ub)). Blocked shear wall nominal unit shear capacity is not to be adjusted by Table 4.3A footnote 2 even if unblocked shear wall construction consists of studs spaced a maximum of 16 in. o.c. or panels applied with the long dimension across studs. To account for the reduction in unblocked shear wall stiffness, which is proportional to the reduction in strength, SDPWS 4.3.4.3 specifies that deflection of unblocked shear walls is to be calculated from standard deflection equations using an amplified value of induced unit shear equal to ν/C(ub). Substituting ν/C(ub) for ν in SDPWS Equation 4.3-1 results in the following equation for unblocked shear wall deflection: 99 100 Table C4.3.4A SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Data Summary for Structural Fiberboard, Gypsum Wallboard, Gypsum Sheathing, and Lumber Sheathed Shear Walls 1. Calculated shear deflections, δ, and actual deflections from shear wall tests are based on unit shears provided in Table C4.3.4A. For Structural Fiberboard Sheathing and Lumber Sheathing, the unit shears are associated with 1.4νs(ASD). For walls tested, small aspect ratio and use of hold-down rods (ASTM E72) or use of hold-downs (ASTM E546) in testing of gypsum wall board shear walls (57) is assumed to keep bending and hold-down slip components of deflection small relative to the shear component of deflection. 2. Unit shear and apparent shear stiffness in SDPWS Table 4.3C for ½ in. GWB with 7 in. fastener spacing multiplied by 7/8 to approximate unit shear and stiffness for GWB tested assemblies using 8 in. fastener spacing. The unit shear values for gypsum, used for comparison purposes, exceed those associated with 1.4νs(ASD) and are not intended to be used for design. 3. Calculated unit shear and Ga for the two-sided test assembly based on SDPWS 4.3.5.4.1. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.3.4-1 101 Calculate the Apparent Shear Stiffness, Ga, in SDPWS Table 4.3A EXAMPLE C4.3.4-2 Calculate Δa for use in the Third Term of Equation 4.3-1 For the shear wall shown in Figure C4.3.4B, calculate Δa and use it to estimate the component of shear wall deflection due to rigid-body overturning, as represented in the third term of Equation 4.3-1. The wood structural panel shear wall is 8 ft high, 2.5 ft in length, and is framed with No. 2 Douglas fir 2x4 studs and plates. The end posts are double 2x4’s with total cross section area of 10.5 in2. From the hold-down device manufacturer’s literature, the LRFD design load is 7900 lb, corresponding vertical elongation of the hold-down device is 0.158 in. at the LRFD design load. Strength level loading (LRFD) is used in this example to illustrate calculation of deflections suitable for comparison against ASCE 7 prescribed seismic drift limits. Calculate the tension force, T, and compression force, C: (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS As with diaphragms, the Ga values for shear walls sheathed with 3-ply plywood and OSB sheathing are explicitly included in Table 4.3A. As outlined in the Table 4.3A footnotes and further explained in C4.2.7.2 for diaphragms, the shear stiffnesses for 4-ply plywood, 5-ply plywood and composite panels are permitted to be approximated by increasing the Ga of 3-ply plywood by a factor of 1.2. “Composite panel”, as used in table footnote 4, refers to a panel containing a combination of veneer and other wood-based material that meets performance criteria for its type in DOC PS1 or PS2 and is not intended to describe OSB, which has its own tabulated values of Ga. 102 EXAMPLE C4.3.4-2 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Calculate Δa for use in the Third Term of Equation 4.3-1 (continued) Figure C4.3.4A Bottom Plate Compression Deformation (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.3.4-2 Calculate Δa for use in the Third Term of Equation 4.3-1 (continued) Figure C4.3.4B Rigid Body Overturning Component of Shear Wall Deflection 103 C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 104 EXAMPLE C4.3.4-3 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Derivation of Constants for Equation 4.3-1 End Deflection of Shear Wall with Concentrated Load at End C4.3.5 Shear Capacities C4.3.5.1 See C4.1.4 for calculation of ASD shear capacity and LRFD factored unit shear resistance. C4.3.5.2 Tabulated Nominal Unit Shear Capacities in Tables 4.3A, 4.3B, 4.3C, and 4.3D are based on adjustment of allowable design values from building codes and industry reference documents (See C2.2) and are predicated on using products that comply with the product standards referenced in this Standard. Tables 4.3A and 4.3B list nominal unit shear capacities for Wood Structural Panels in three distinct groupings: Structural I Sheathing, Sheathing, and Plywood Siding. Structural I Sheathing and Sheathing are applicable for wood structural panels in conformance with requirements of PS1 and PS2 (58, 8). The Structural I designation is associated with panels that meet additional requirements including those for cross-panel strength and stiffness and for racking load performance. For Plywood Siding, tabulated nominal unit shear capacities are associated with reduced thickness at ornamental grooves and panel shiplap joints. The combination of a small head galvanized casing nail (see Table C.4.3.5.1) and nail- ing through the reduced thickness portion of the siding panel further reduces the shear resistance, as compared with other panel types and fastener options. Except for Plywood Siding of Group 5 species (e.g., Basswood and Balsam Poplar) as defined in PS 1, nominal unit shear capacities associated with the “Sheathing” designation are applicable for Plywood Siding when nailed with the larger galvanized box or common nails and the nominal panel thickness is determined at the point of nailing along panel edges. Table C4.3.5.1 Dimension of Galvanized Casing Nails in Accordance with ASTM F1667 (59) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC termediate stud spacing (e.g., for 19.2 in. stud spacing C(ub) = 0.52 for sheathing nailed with 6 in. nail spacing at supported edges and 12 in. nail spacing at intermediate framing). C4.3.5.4.1 For two-sided walls with the same sheathed wood-frame shear wall systems on opposite sides (see C4.3.7) and the same construction (either blocked or unblocked) on opposite sides, SDPWS Equation 4.3-3 and SDPWS Equation 4.3-4 provide for determination of combined stiffness and unit shear capacity based on relative stiffness of each side. Using the equations, a wall having identical construction on each side (e.g., a two-sided wall) has twice the capacity of a wall sheathed on one side (e.g., a one-sided wall). Although not common for new construction, use of the same sheathed wood-frame shear wall system on both sides of the wall but with different sheathing thickness or fastening schedule (i.e., size and spacing of nails) on opposing sides is permissible and the combined strength and stiffness is addressed by provisions of 4.3.5.4.1. Two-sided walls having the same sheathed wood-frame shear wall system on both sides but with different sheathing thickness or fastening schedule on opposing sides is more likely to occur in retrofit of existing construction. C4.3.5.4.2 Where strength and stiffness for seismic design is based on provisions for two-sided walls with different sheathed wood-frame shear wall systems on each side (e.g., Gypsum Board shear walls on side one and Wood Structural Panel shear walls on side two), the combined unit shear capacity is required to be taken as twice the smaller nominal unit shear capacity or taken as the larger nominal unit shear capacity, whichever is greater. Due to lateral system combination rules for seismic design (5), the two-sided unit shear capacity based on different sheathed wood-frame shear wall systems on each side of the wall will require use of the lesser seismic response modification coefficient, R, for calculation of seismic loads. Where a two-sided shear wall consisting of wood-structural panel exterior shear walls and gypsum wallboard interior shear walls is used for the structural design, R = 2 is applicable where shear wall design is based on two times the capacity of the gypsum wallboard shear walls because R = 2 (associated with gypsum wallboard shear walls in a bearing wall system per ASCE 7) is the lesser R contributing to the two-sided shear wall design capacity. For the same wall condition, when design is based on wood structural panel shear wall capacity alone, R = 6.5 (associated with wood structural panel shear walls in a bearing wall system per ASCE 7) is applicable and commonly employed for design of Wood Structural Panel shear walls as the seismic force resisting Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Tables 4.3A and 4.3B nominal unit shear capacities are applicable for wood structural panels of the minimum nominal panel thickness specified. The use of “minimum nominal panel thickness” in the Table 4.3A and 4.3B column headings is to accommodate use of the tabulated nominal unit shear capacities for structural panels of greater thickness provided that nails with the prescribed dimensions are used and that bearing length of the nail into framing exceeds the prescribed minimum bearing length. This allowance recognizes that greater structural panel thickness will also develop the strength of the prescribed nailing upon which the nominal capacities are based. Nails are identified by name and dimensions (e.g., 8d common is 2.5 in. long by 0.131 in. diameter with a 0.281 in. diameter head) to reflect fasteners upon which tabulated nominal unit shear capacities are based. Nails of different type or dimensions are considered alternatives to the specified nails. For nails of matching diameter, but shorter in length than those specified in SDPWS, testing (18, 74, 75) indicates varied results depending on loading protocol and test boundary conditions. Tested performance of 10d “short” nails (75) indicates reduced strength and deformation capacity relative to the specified 10d common nail (76) when tested under nominally identical conditions that included cyclic and monotonic loading and varying test boundary conditions. The range of strength reduction observed for the 10d “short” nail ranged from approximately 5% to 20%. C4.3.5.3 Unblocked Wood Structural Panel Shear Walls: Monotonic and cyclic tests of unblocked wood structural panel shear walls (18, 27, and 28) are the basis of the unblocked shear wall factor, C(ub), which accounts for reduced strength and stiffness of unblocked shear walls when compared to similarly constructed blocked shear walls. Test results show comparable displacement capacity characteristics to similarly constructed blocked wood structural panel shear walls over a range of unblocked panel configurations. Tests included a range of panel edge and field nail spacing, stud spacing, wall height, gap distance at adjacent unblocked panel edges, and simultaneous application of gravity load. The maximum unblocked shear wall height tested was 16 ft and the maximum gap distance between adjacent unblocked panel edges was 1/2 inch. Maximum unit shear capacities are limited to values applicable for 6 in. o.c. panel edge nail spacing regardless of actual panel edge nail spacing used. The limit on maximum unit shear is to address limited observations of stud splitting in walls tested to higher shear capacities associated with panel edge nail spacing of 4 in. o.c. Interpolation of C(ub) is permissible for in- 105 106 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS system. For wind design, direct summing of the contribution of gypsum wallboard shear walls with the unit shear capacity of wood structural panel shear walls, structural fiberboard shear walls, or hardboard panel siding is permitted based on tests (10 and 15). Figure C4.3.5 illustrates the provisions in Footnote Figure C4.3.5 6 of Table 4.3A and Footnote 5 of Table 4.3B requiring panel joints to be offset to fall on different framing members when panels are applied on both faces of a shear wall, nail spacing is less than 6 in. on center on either side, and the framing member nailed face width is less than 3x framing. Detail for Adjoining Panel Edges where Structural Panels are Applied to Both Faces of the Wall C4.3.5.5 Shear Walls in a Line: The provisions for distribution of shear force to shear walls in a shear wall line are limited to shear walls with the same sheathed wood-frame shear wall systems. Sheathed wood-frame shear wall systems are a prescribed combination of sheathing type and fastener type for attachment to wood framing (see C4.3.7). The intended purpose of the requirement is to limit applicability of provisions to shear walls of the same sheathing type and fastener type (e.g., nailed wood structural panels, or nailed structural fiberboard) that exhibit similar load-deformation behavior up to failure. Nailed wood structural panel shear walls, regardless of sheathing grade or thickness and nailing schedule are considered to exhibit compatible behavior. For example, the combination of a shear wall with 2 in. panel edge nail spacing in line with a shear wall with 6 in. panel edge nail spacing does not violate the intent of same sheathed wood-frame shear walls systems for applicability of SDPWS 4.3.5.5. Similarly, the combination of shear wall types, such as perforated shear walls, FTAO shear walls, and individual full-height segments as well as blocked and unblocked shear walls within a shear wall line is also permissible. Provisions for shear force distribution apply whether force is from wind or seismic and for shear walls of any length. C4.3.5.5.1 The distribution of shear force to shear walls in a line is in proportion to the stiffness of each shear wall. In design, at a given deflection the force in each wall is determined by multiplying the wall stiffness times the deflection (e.g., commonly referred to as distribution based on relative stiffness or the equal deflection approach). For all but the case where a wall line is comprised entirely of equal stiffness shear walls, this approach results in a design capacity of the shear wall line that is less than would result from the sum of shear wall lengths times the full design unit shear capacity, because for a given deflection, full unit shear forces are not developed simultaneously in all walls (see Example C4.3.5.5.1-1). The design capacity of the shear wall line will be the sum of the forces in each shear wall at a given deflection. The limiting value of deflection may be associated with the shear wall in the line whose design strength occurs at the smallest deflection of any shear wall in the wall line or may be associated with drift or deflection limits. Drift limits for resistance to seismic forces are provided in ASCE 7 and vary by building risk category, story height, and construction material. For sheathed woodframe shear wall structures, story drift limits for seismic design range from 1% to 2.5% of the story height. While there is no prescribed deflection limit for wind design, Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC consideration should be given to limiting deflections to avoid serviceability problems associated with finish materials and operability of doors and windows. Compliance with construction and materials requirements and associated design unit shear capacities in SDPWS for wind design have been considered to provide acceptable serviceability performance for resistance to wind loads. A simplified approach is also permitted for distribution of shear force to shear walls in a line. In lieu of distribution of shear based on the equal deflection calculation method, it is permitted to distribute shear in proportion to the strength of the shear wall provided that certain requirements are met. For wood structural panel shear walls, including those with gypsum wallboard on the opposite side, distribution of shear in proportion to shear strength of each shear wall is permitted provided that shear walls with aspect ratio greater than 2:1 have strength adjusted by the 2b/h factor. For structural fiberboard shear walls, including those with gypsum wallboard on the opposite side, distribution in proportion to EXAMPLE C4.3.5.5.1-1 shear strength of each shear wall is permitted provided that shear walls with aspect ratio greater than 1:1 have strength multiplied by the 0.1+0.9b/h factor. Both factors are based on reduced stiffness observed from testing (29, 35, and 36) and provide roughly similar results to equal deflection for a reference wall line configuration comprised of 1:1 to 3.5:1 aspect ratio walls (see Example C4.3.5.5.1-2). This simplified method was judged suitable for design purposes for any combination of shear wall lengths. Where distribution of shear is based on the simplified alternative adjustment factor methods (e.g., 2b/h for wood structural panels and 0.1+0.9b/h for structural fiberboard), further reduction of shear strength by the aspect ratio factors in 4.3.3.2 is not required because the strength reductions to provide for deflection compatibility represent the more conservative of the adjustments to account for reduced stiffness and reduced strength of high aspect ratio shear walls. Calculate the ASD Shear Capacity (Seismic) of Shear Walls in a Line Using the Equal Deflection Calculation Approach Figure C4.3.5B Illustration of Equal Deflection Calculation Method Shear Wall Line The solution approach is to determine the proportion of load in each shear wall at a given deflection by use of the SDPWS shear wall deflection equations and then summing the shears to arrive at an ASD shear capacity for the shear wall line (Figure C4.3.5B). (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Calculate the ASD shear capacity for the shear wall line as shown in Figure C4.3.5A using the equal deflection calculation approach. The individual blocked wood structural panel shear walls are constructed with 15/32 in. thick wood structural panel sheathing (OSB) attached to No.2 Douglas fir 2x4 framing with 8d nails (common or galvanized box) spaced at 6 in. and have a reference nominal unit shear value of 730 plf and apparent shear stiffness, Ga, of 13 kips/in. The end posts for both walls are double 2x4’s. Figure C4.3.5A 107 108 EXAMPLE C4.3.5.5.1-1 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Calculate the ASD Shear Capacity (Seismic) of Shear Walls in a Line Using the Equal Deflection Calculation Approach (continued) Shear Wall 1 (SW1): Nominal unit shear capacity, νn = 730 plf (SDPWS Table 4.3A) SW1 Aspect ratio (h/b) = 1.0 Aspect Ratio Factor (WSP) for strength = 1.0 (Aspect ratio adjustment is not applicable because h/b ≤2, see SDPWS 4.3.3.2) ASD unit shear capacity for seismic, νSW1 =730 plf/2.8 x1.0 = 260.7 plf Ga = 13.0 kips/in EA = 16,800,000 lb Shear Wall 2 (SW2): Nominal unit shear capacity, νn = 730 plf (SDPWS Table 4.3A) SW2 Aspect ratio (h/b) =3.5 Aspect Ratio Factor (WSP) for strength =1.25 - 0.125 (h/b) = 0.81 (SDPWS 4.3.3.2) ASD unit shear capacity for seismic, νSW2 =730 plf/2.8 x 0.81 = 211.2 plf Ga = 13.0 kips/in EA = 16,800,000 lb The reference value of Δa (i.e., vertical deformation associated with overturning anchorage system plus compression deformation) for SW1 is 1/8 in. at 3500 lb load (calculation not shown). Assuming linear elastic response, the stiffness is kSW1=3500 lb/0.125 in. = 28,000 lb/in. For overturning T force of 2224.8 lb, Δa for SW1 is:Δa,SW1 =2224.8 lb/3500 lb x 0.125in. =0.079 in. For purposes of this example, overturning resistance contributed by dead load is ignored. See Example C4.3.4-2 for an example for calculation of Δa. Part 2 – Determine the unit shear in SW2 that produces the same deflection as SW1 Using equation 4.3-1, solve for unit shear that produces equal deflection to SW1: Recognizing that the deflection of SW1 associated with the ASD unit shear capacity of 260.7 plf is smaller than the deflection of SW2 associated with the ASD unit shear capacity of 211.2 plf, the problem can be simplified to finding the reduced design unit shear in the less stiff SW2 that produces the same deflection as SW1. Part 1 – Determine the deflection of SW1 at its ASD unit shear capacity Deflection associated with the ASD unit shear capacity is calculated in accordance with the following equation based on SDPWS Equation 4.3-1: For SW2, the overturning anchorage system stiffness is 23,400 lb/in. (i.e., for the same hold-down and post configuration, the reduced stiffness for SW2 when compared to SW1 results from the larger ratio of b/ beff for SW2). For overturning T force of 1130 lb, the corresponding Δa,SW2 is: Δa,SW2 = 1,130lb/23,400 lb/in = 0.048 in. For purposes of this example, overturning resistance contributed by dead load is ignored. νSW2 = 110.6 plf ≤ 211.2 plf; OK –110.6 plf controls The induced unit shear of 110.6 plf does not exceed the unit shear capacity of 211.2 plf determined from aspect ratio strength reductions in accordance with 4.3.3.2. (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC EXAMPLE C4.3.5.5.1-1 109 Calculate the ASD Shear Capacity (Seismic) of Shear Walls in a Line Using the Equal Deflection Calculation Approach (continued) Deflection associated with this unit shear is confirmed to equal 0.247 in. calculated in accordance with the following equation based on SDPWS Equation 4.31: This example illustrates calculation of the ASD shear capacity (for seismic) for the shear wall line (i.e., VShear wall line = 2340 lb). Distribution of shear by the equal deflection calculation method is equally applicable to a more typical design problem where a design load is associated with a given shear wall line and the shear wall line is designed to provide resistance in excess of the design load. This calculation example includes a check of the induced unit shear in each shear wall (i.e., SW1 and SW2) to ensure that unit shear does not exceed the unit shear capacity determined from aspect ratio strength reductions in accordance with 4.3.3.2. Part 3 – Sum design strengths associated with distribution of shear based on the equal deflection calculation approach VSW1 VSW2 VShear wall line = 260.7 plf x 8 ft = 2085.6 lb = 110.6 plf x 2.3 ft = 254.4 lb = 2085.6 lb + 254.4 lb = 2340 lb Calculate the ASD Shear Capacity (Seismic) of Shear Walls in a Line Using the Exception to 4.3.5.5.1 Calculate the ASD shear capacity for the shear wall line from example C4.3.5.5.1-1. In lieu of the equal deflection calculation approach of 4.3.5.5.1, the solution approach is based on the Exception to 4.3.5.5.1 which permits distribution of shear in proportion to strength where strength of wood structural panel shear walls is adjusted by the 2b/h factor. Unit shear capacity from 4.3.5.5.1 Exception 1 does not exceed the unit shear capacity determined from aspect ratio strength reductions in accordance with 4.3.3.2. Shear Wall 1 (SW1): Nominal unit shear capacity, νn = 730 plf (SDPWS Table 4.3A) SW2 Aspect ratio (h/b) = 3.5 SW1 Aspect ratio (h/b) = 1.0 Aspect ratio adjustment = 1.0 (SDPWS 4.3.5.5.1 Exception 1) Aspect Ratio Factor (WSP) for strength = 1.0 (Aspect ratio adjustment is not applicable because h/b ≤ 2, see SDPWS 4.3.3.2) Shear Wall 2 (SW2): Nominal unit shear capacity, νn = 730 plf (SDPWS Table 4.3A) Aspect ratio adjustment = 2b/h = 0.57 (SDPWS 4.3.5.5.1 Exception 1) Aspect Ratio Factor (WSP) for strength = 1.25 - 0.125 (h/b) = 0.81 (SDPWS 4.3.3.2) ASD unit shear capacity for seismic, νSW2 = 730 plf/2.8 x 0.57 = 148.6 plf ASD unit shear capacity for seismic, νSW1 = 730 plf/2.8 x1.0 = 260.7 plf (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS EXAMPLE C4.3.5.5.1-2 C 110 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS EXAMPLE C4.3.5.5.1-2 Calculate the ASD Shear Capacity (Seismic) of Shear Walls in a Line Using the Exception to 4.3.5.5.1 (continued) The ASD unit shear capacity calculated using the aspect ratio adjustment from 4.3.5.5.1 Exception 1 controls since it is less than the ASD unit shear capacity determined from aspect ratio strength reductions in accordance with 4.3.3.2. Sum design strengths associated with distribution of shear based on the aspect ratio adjustment approach (e.g., 4.3.5.5.1 Exception): Note: This example illustrates the calculation approach in accordance with 4.3.5.5.1 Exception 1. The aspect ratio adjustment, 2b/h is not applied cumulatively with the Aspect Ratio Factor (WSP) for strength reduction of 4.3.3.2. Both are evaluated as separate checks on design shear strength. VSW1 = 260.7 plf x 8 ft = 2085.6 lb VSW2 = 148.6 plf x 2.3 ft = 341.8 lb VShear wall line = 2085.6 lb + 341.8 lb = 2427 lb C4.3.5.6 Shear Capacity of Perforated Shear Walls: The shear capacity adjustment factor, Co, for perforated shear walls accounts for reduced shear wall capacity due to presence of openings and is derived from empirical Equations C4.3.5.6-1 and C4.3.5.6-2 (13): Full-scale perforated shear wall tests include monotonic and cyclic loads, long perforated shear walls with asymmetrically placed openings, perforated shear walls sheathed on two sides, and perforated shear walls with high aspect ratio shear wall segments (15, 42, 43, and 44). The calculation of the PSW shear capacity adjustment factor, Co, is based on an area adjustment, using the total area sheathed with full-height sheathing, Afhs, without any adjustment based on aspect ratio limits in 4.3.3.4. The Co factor used with the perforated shear wall method reduces the shear capacity of a fully-sheathed, full-height shear wall for the effects of openings (unsheathed areas) in the shear wall. The empirical equation for Co was derived based on the ratio of the total area Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC of openings (unsheathed areas) to the total area of the perforated shear wall and the ratio of the total area of fully-sheathed, full-height areas to the total area of the perforated shear wall. Adjustment of the length of each fully-sheathed, full-height segment, bi, with an aspect ratio greater than 2:1 in the ∑bi term of Equation 4.3-5 is a further adjustment that is separate from calculation of Co and is intended to limit the contribution from high aspect ratio segments in the calculation of the nominal shear capacity Vn, of the perforated shear wall. 111 Figure C4.3.6.1.2 Tension and Compression Force Couple due to Shear Wall Overturning Moment C4.3.6 Construction Requirements C C4.3.6.1.3 Tension and Compression Chords of Perforated Shear Walls: SDPWS Equation 4.3-8 provides for calculation of tension force and compression force at each end of a perforated shear wall, due to shear in the wall, and includes the term 1/Co to account for the nonuniform distribution of shear in a perforated shear wall. For example, a perforated shear wall segment with tension end restraint at the end of the perforated shear wall can develop the same shear capacity as an individual fullheight wall segment (7). C4.3.6.3 Fasteners: Details on type, size, and spacing of mechanical fasteners used for typical shear wall assemblies in Table 4.3A, 4.3B, 4.3C, and 4.3D are provided in SDPWS 4.3.7 Sheathed Wood-Frame Shear Wall Systems. C4.3.6.3.1 Adhesives: Adhesive attachment of shear wall sheathing is generally prohibited unless approved by the authority having jurisdiction. Because of limited ductility and brittle failure modes of rigid adhesive shear Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.3.6.1 Framing Requirements: Framing requirements are intended to ensure that boundary members and other framing are adequately sized to resist induced loads. C4.3.6.1.1 General framing requirements for shear walls permits the use of two 2x members in lieu of a single member, provided they are adequately connected for transfer of induced shear forces. Cyclic tests of shear walls confirms that use of two 2x members nailed (22, 25, and 30) or screwed (33) together results in shear wall performance that is comparable to that obtained by use of a single 3x member at the adjoining panel edge. While introduced as a substitute for a 3x member at adjoining panel edges in shear wall construction, it is also permissible to use two 2x members to substitute for a single 2x member (e.g., for blocking, and top plates). Design capacity for the connection of the two 2x members to each other must equal or exceed design unit shear forces in the shear wall. As an alternative, the design capacity of the connection between the two 2x members must equal or exceed the capacity of the sheathing to framing attachment. Where fastener spacing used in the interconnection of the two 2x stud members is closer than 4 in. on center, staggered placement is required to limit potential for wood splitting. C4.3.6.1.2 Tension and Compression Chords: SDPWS Equation 4.3-7 provides for calculation of tension and compression chord force due to induced shear acting at the top of the wall, wall height, and moment arm associated with resolving overturning moment into a tension and compression force couple (see Figure C4.3.6.1.2). To provide an adequate load path per SDPWS 4.3.6.4.4, design of elements and connections must consider forces contributed by each story (i.e., shear and overturning moment must be accumulated and accounted for the design) 112 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS wall systems (38) such systems are limited to seismic design categories A, B, and C and the values of R and Ω0 are limited (R = 1.5 and Ω0 = 2.5 unless other values are approved). If adhesives are used to attach shear wall sheathing, the effects of increased stiffness (see C4.1.3 and C4.1.7), increased strength, and potential for brittle failure modes corresponding to adhesive or wood failure, should be addressed. Tabulated values of apparent shear stiffness, Ga, are based on assumed nail slip behavior (see Table C4.2.3D) and are therefore not applicable for adhesive shear wall systems where shear wall sheathing is rigidly bonded to shear wall boundary members. C4.3.6.4.1.1 In-plane Shear Anchorage for Perforated Shear Walls: SDPWS Equation 4.3-9 for in-plane shear anchorage includes the term 1/Co to account for non-uniform distribution of shear in a perforated shear wall. For example, a perforated shear wall segment with tension end restraint at the end of the perforated shear wall can develop the same shear capacity as an individual full-height wall segment (7). C4.3.6.4.2.1 Uplift Anchorage for Perforated Shear Walls: Attachment of the perforated shear wall bottom plate to elements below is intended to ensure that the wall capacity is governed by sheathing to framing attachment (shear wall nailing) and not bottom plate attachment for shear (see C4.3.6.4.1.1) and uplift. An example design (7) provides typical details for transfer of uplift forces. C4.3.6.4.3 Anchor Bolts: Plate washer size and location are specified for anchoring of wall bottom plates to minimize potential for cross-grain bending failure in the bottom plate (see Figure C4.3.6A). For a 3 in. x 3 in. plate washer centered on the wide face of a 2x4 bottom plate, edges of the plate washer are always within 1/2" of the sheathed side of the bottom plate. For wider bottom plates, such as 2x6, a larger plate washer may be used so that the edge of the plate washer extends to within 1/2 in. of the sheathed side, or alternatively, the anchor bolt can be located such that the 3 in. x 3 in. plate washer extends to within 1/2 in. of the sheathed side of the wall. The washer need not extend to within 1/2 in. of the sheathed edge where sheathing material nominal unit shear capacity is less than or equal to 400 plf nominal. This allowance is based on observations from tests and field performance of gypsum products where sheathing fastener tear-out or sheathing slotting at fastener locations were the dominant failure modes. Other sheathing materials with nominal unit shear capacity less than 400 plf nominal are included in this provision based on the judgment that the magnitude of unit uplift force versus sheathing type is the significant factor leading to poten- tial for bottom plate splitting. Cyclic testing of wood structural panel shear walls (25 and 30) forms the basis of the exception to the 1/2 in. distance requirement. In these tests, edge distance was not a significant factor for shear walls having fulloverturning restraint provided at end posts. Overturning restraint of wall segments coupled with the nominal capacity of walls tested were viewed as primary factors in determining wall performance and failure limit states. Bottom plate anchor straps can also be effective in mitigating cross-grain bending failure in the bottom plate provided they have been properly tested, load rated, and installed on the sheathed side of the bottom plate. The extension of plate washer requirements to foundation sill plate applications is depicted in Figure C4.3.6B. Locating the washer’s edge within 1/2 in. of the sheathed edge is accomplished by placement of cuts, notches or holes in the rim board or blocking. The extent of such alterations to the rim board or blocking for placement of the washer should be kept to a practical minimum and be in accordance with the manufacturer’s recommendations or be specifically addressed in the design of the member. Anchor bolt connections designed per SDPWS 4.3.6.4.3 are designed for the shear load in the sill plate. If the shear capacity of a double-sided shear wall is twice that of a single-sided shear wall, the anchor bolt spacing derived based on the anchor bolt shear capacity for a double-sided shear wall would be half the spacing of a single-sided shear wall. Staggering the anchor bolts 1/2 in. from the plate edge for a double-sided shear wall provides uplift resistance on each edge of the sill plate equivalent to a single row of anchor bolts located 1/2 in. from the plate edge on a single-sided shear wall. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Figure C4.3.6A 113 Distance for Plate Washer Edge to Sheathed Edge Figure C4.3.6B Section and Elevation View of Plate Washer in Foundation Sill Plate (Raised Floor) Application C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 114 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.3.6.4.4 Load Path: Specified requirements for shear, tension, and compression in SDPWS 4.3.6 are to address the effect of induced unit shear on individual wall elements. Overall design of an element must consider forces contributed from multiple stories (i.e., shear and moment must be accumulated and accounted for in the design). In some cases, the presence of load from stories above may increase forces (e.g., effect of gravity loads on compression end posts) while in other cases it may reduce forces (e.g., effect of gravity loads reduces net tension on end posts). Consistent with a continuous load path for individual full-height wall segments and force transfer shear walls, a continuous load path to the foundation must also be provided for perforated shear walls. Consideration of accumulated forces (for example, from stories above) is required. Accumulation of forces will affect hold-downs at each end of the perforated shear wall, compression resistance at each end of each perforated shear wall segment, and distributed forces, ν and t, at each perforated shear wall segment. Where ends of perforated shear wall segments occur over beams or headers, the beam or header will need to be checked for vertical tension and compression forces in addition to gravity forces. Where adequate collectors are provided to distribute shear, the average shear in the perforated shear wall above (e.g., equivalent to design shear loads), and not the increased shear for anchorage of upper story wall bottom plates to elements below (7), needs to be considered. C4.3.7 Sheathed Wood-Frame Shear Wall Systems Requirements for sheathed wood-frame shear wall systems including shear wall sheathing materials, framing, and nailing are consistent with industry recommendations and building code requirements. The term “sheathed wood-frame shear wall system” denotes the combination of sheathing material type and fastener type on one or both sides of a wood-frame shear wall. The terminology recognizes that shear walls of the same sheathing type and fastener type (e.g., nailed wood structural panels, or nailed structural fiberboard) exhibit similar load-deformation behavior up to failure. Nailed wood structural panel shear walls are considered to exhibit compatible behavior over the range of sheathing thicknesses, sheathing grades and fastener size and spacings addressed by SDPWS. The minimum width of the nailed face of framing members and blocking for all shear wall types is 2 in. nominal with maximum spacing between framing of 24 in. o.c. Edges of wood-based panels (wood structural panel, particleboard, and structural fiberboard) are required to be backed by blocking or framing except as specified in SDPWS 4.3.5.3. In addition, fasteners are to be placed at least 3/8 in. from edges and ends of panels but not less than distances specified by the panel manufacturer in the manufacturers’ literature or code evaluation report. C4.3.7.1 Wood Structural Panel Shear Walls: For wood structural panel shear walls, framing members or blocking is required at edges of all panels except as specified in SDPWS 4.3.5.3 and a minimum panel dimension of 4 ft x 8 ft is specified except at boundaries and changes in framing. Shear wall construction is intended to consist primarily of full-size sheets except where wall dimensions require use of smaller sheathing pieces (e.g., where shear wall height or length is not in increments of 4 ft, shear wall height is less than a full 8 ft, or shear wall length is less than 4 ft). Racking tests conducted on 4.5 ft x 8.5 ft blocked shear walls showed similar performance whether sheathed length and height consisted of: one 4 ft x 8 ft panel and two 6 in. wide sheathing pieces to make up the height and length, or one 2.5 ft x 6.5 ft panel and two 2 ft wide sheathing pieces to make up the height and length (14). C4.3.7.1(5): A single 3x framing member is specified at adjoining panel edges for cases prone to splitting and where nominal unit shear capacity exceeds 980 plf in seismic design categories (SDC) D, E, and F. An alternative to single 3x framing, included in SDPWS, and based on principles of mechanics, is the use of 2-2x “stitched” or interconnected two 2x members adequately fastened together (See C4.3.6.1.1 for additional information). For sheathing attachment to framing with closely spaced or larger diameter nails, staggered nail placement at each panel edge is intended to prevent splitting in the framing member (Figure C4.2.8). The staggering of fasteners also increases distance from the nail to the edge of the sheathing which has been observed to improve strength in shear wall testing as opposed to placing all sheathing fasteners at the minimum panel edge distance. The amount of stagger is not prescribed because even a slight stagger, such as 1/8 in., is considered to meet the intent of the requirement. C4.3.7.1.1 Seismic Equivalency of Alternative Sheathed Wood-Frame Shear Wall Systems: Wood structural panel shear walls designed in accordance with SDPWS requirements employ prescribed combinations of wood structural panel grade and thickness, wood framing, and sheathing nailing. This sheathed wood-frame shear wall system is associated with specific seismic performance factors (R, Cd and Ω0) in ASCE 7. When Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC panels (see C4.3.7.1). Apparent shear stiffness in SDPWS Table 4.3A is based on assumptions of relative stiffness and nail slip (see C4.2.3 and C4.3.4). For closely spaced or larger diameter nails, staggered nail placement at each panel edge is intended to prevent splitting in the framing member (Figure C4.2.8). C4.3.7.4 Structural Fiberboard Shear Walls: Panel size requirements are consistent with those for wood structural panels (see C4.3.7.1). Apparent shear stiffness in SDPWS Table 4.3A is based on assumptions of relative stiffness and nail slip (see C4.2.3 and C4.3.4). Minimum panel edge distance for nailing at top and bottom plates is 3/4" to match edge distances present in cyclic tests of high aspect ratio structural fiberboard shear walls (29). C4.3.7.5 Gypsum Wallboard, Gypsum Veneer Base, Water-Resistant Backing Board, or Gypsum Sheathing Shear Walls: The variety of gypsum-based sheathing materials reflect systems addressed in the model building code (2). Appropriate use of these systems requires adherence to referenced standards for proper materials and installation. Where gypsum wallboard is used as a shear wall, edge fastening (e.g., nails or screws) in accordance with SDPWS Table 4.3C requirements should be specified and overturning restraint provided where applicable (see SDPWS 4.3.6.4.2). Apparent shear stiffness in SDPWS Table 4.3C is based on assumptions of relative stiffness and nail slip (see C4.2.3 and C4.3.4). C4.3.7.6 Gypsum Lath and Plaster or Portland Cement Plaster Shear Walls: The nominal unit shear capacity and apparent shear stiffness values for plain or perforated gypsum lath with staggered vertical joints are based on results from cyclic tests (31). Unit shear capacity and apparent shear stiffness values are larger than those for plain or perforated gypsum lath where vertical joints are not staggered. C4.3.7.7 Single-Layer Diagonally-Sheathed Lumber Shear Walls: Single-layer diagonally-sheathed lumber shear walls have comparable strength and stiffness to many wood structural panel shear wall systems. Apparent shear stiffness in SDPWS Table 4.3D is based on assumptions of relative stiffness and nail slip (see C4.2.3 and C4.3.4). Early reports (24) indicated that diagonally sheathed lumber shear walls averaged four times the rigidity of horizontally sheathed lumber walls when boards were loaded primarily in tension. Where load was primarily in compression, a single test showed about seven times the rigidity of a horizontally sheathed lumber wall. C4.3.7.8 Double-Layer Diagonally-Sheathed Lumber Shear Walls: Double-layer diagonally-sheathed lumber shear walls have comparable strength and stiffness to many wood structural panel shear wall systems. Ap- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS subjected to cyclic loads, wood structural panel shear walls designed in accordance with SDPWS demonstrate desirable ductile yield modes with significant drift capacity, ductility, and overstrength. In addition, the studs are intact following cyclic testing and remain capable of supporting gravity loads. Alternative sheathed woodframe shear wall systems used with or as replacements for wood structural panel shear walls must demonstrate similar behavior for them to share the same seismic performance factors. ASTM D7989 prescribes standard test conditions, loading criteria, and data analysis required for alternative shear wall systems to demonstrate equivalent seismic performance to the reference wood structural panel shear wall construction prescribed in SDPWS. To ensure compatibility with wood structural panel shear walls, an alternative sheathed wood-frame shear wall system must meet or exceed seismic equivalency parameters for component overstrength, drift capacity, and ductility as prescribed in ASTM D7989. In addition, the failure mode must not compromise the integrity of the wall elements that support gravity loads. For example, if the wall or studs buckled during a test that imposed only lateral load, the ability to carry vertical load would also be compromised if both load types were applied simultaneously. The seismic equivalency parameters prescribed by ASTM D7989 were developed from a large database of tests of wood structural panel shear walls, which are described in that standard and encompass the range of wood structural panel shear walls in SDPWS. C4.3.7.2 Shear Walls using Wood Structural Panels over Gypsum Wallboard or Gypsum Sheathing Board: Sheathed wood-frame shear walls with wood structural panels applied over gypsum wallboard or gypsum sheathing are commonly used for exterior walls of buildings that are fire-resistance-rated for both interior and exterior fire exposure. For example, a one-hour fire resistance rating can be achieved with 5/8 in. Type X gypsum wallboard. Nominal unit shear capacities and apparent shear stiffness values in Table 4.3B for 8d and 10d nails (common or galvanized box) are based on nominal unit shear capacities and apparent shear stiffness values in Table 4.3A for 6d and 8d nails (common or galvanized box), respectively, to account for the effect of gypsum wallboard or gypsum sheathing between wood framing and wood structural panel sheathing. Tests of 3/8 in. wood structural panels over ½ in. and 5/8 in. gypsum wallboard support using lower nominal unit shear capacities associated with smaller nails (18). C4.3.7.3 Particleboard Shear Walls: Panel size requirements are consistent with those for wood structural 115 116 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS parent shear stiffness in SDPWS Table 4.3D is based on assumptions of relative stiffness and nail slip (see C4.2.3 and C4.3.4). C4.3.7.9 Single-Layer Horizontally-Sheathed Lumber Shear Walls: Single-layer horizontally-sheathed lumber shear walls have limited unit shear capacity and stiffness when compared to those provided by wood structural panel shear walls of the same overall dimensions. Early reports (21 and 24) attributed strength and stiffness of lumber sheathed walls to nail couples at stud crossings and verified low unit shear capacity and stiffness when compared to other bracing methods. C4.4 Wood Structural Panels Used in Walls Designed to Resist Combined Shear and Uplift from Wind C4.4.1 Application Panels with a minimum thickness of 7/16 in. and strength axis oriented parallel to studs are permitted to be used in combined uplift and shear applications for resistance to wind forces. Tabulated values of nominal uplift capacity (see SDPWS Table 4.4.1) for various combinations of nailing schedules and panel type and thickness are based on calculations in accordance with the National Design Specification (NDS) for Wood Construction and verified by full scale testing (39 and 40). ASD and LRFD unit uplift and shear capacities are calculated as follows from nominal unit uplift and shear values. Examples C4.4.1-1 and C4.4.2-1 illustrate how the values in SDPWS Tables 4.4.1 and 4.4.2, respectively, were generated. Tabulated values of nominal uplift capacity in Table 4.4.1 and Table 4.4.2 are based on assumed use of framing with specific gravity, G, equal to 0.42. An increase factor is provided in table footnotes to adjust values for effect of higher specific gravity framing on the strength of the nailed connection between sheathing and framing. Where lower specific gravity framing is used, reduced values of nominal uplift capacity are applicable based on the effect of lower specific gravity framing on the strength of the nailed connection between sheathing and framing – for example, the reduction factor is 0.92 for framing with G = 0.35. Adjustment factors over a range of framing specific gravity can be determined as follows: Specific Gravity Adjustment Factor = [1-(0.5-G)]/0.92 for 0.35 ≤ G ≤ 0.49. C4.4.1.2 Panels: Full-scale testing (see C4.4.1) utilized panels with strength axis oriented parallel and perpendicular to studs. NDS nail connection capacities are independent of panel strength axis orientation. C4.4.1.5 Sheathing Extending to Top Plate: Attachment of wood structural panels to the top plate (see Figure 4G and 4H) is a reference condition for applicability of the specified uplift and shear capacities. Per 4.4.1.5(2), where connectors are used to transfer wind uplift forces from roof framing into the wall sheathing, the connector location is on the same side of the wall as the sheathing to avoid eccentric placement of the uplift connector relative to the wood structural panel sheathing providing wind uplift resistance (see Figure C3.4). An alternative detail used in combination with raised-heel roof trusses is to extend the sheathing edge beyond the upper top plate to facilitate attachment to the raised-heel truss (See Figure C4.4.1.5)(77, 78). In addition to nailing the sheathing to the upper top plate as required by 4.4.1.5(1), added fastening based on design of the connection of the sheathing to the raised-heel truss to transfer wind uplift forces from Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 117 the roof framing into the wall sheathing is required. Figure C4.4.1.5 Raised-Heel Roof Truss Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.4.1.6. Sheathing Extending to Bottom Plate or Sill Plate: Construction requirements for use of wood structural panels to resist uplift and shear closely match construction present in verification tests. For example, testing of shear walls resisting uplift and combined uplift and shear used 16 in. o.c. and up to 48 in. anchor bolt spacing, 3 in. x 3 in. plate washers, and nails with minimum ½ in. to ¾ in. panel edge distance depending on the number of rows of nails. Anchor bolt spacing and size and location of plate washers were found to be important factors enabling strength of the sheathing to bottom plate connection to develop prior to onset of bottom plate failure. Required anchor bolt spacings as shown in Table 4.4.1.6 are a function of the combined uplift and shear forces on the bottom plate and are based on a combination of fullscale tests and numerical analysis (51, 52). Where other anchoring devices are used, it is intended that spacing not exceed the values provided in Table 4.4.1.6 and in addition that such devices enable performance of walls to be comparable to those tested with required anchor bolts and plate washers. Figure C4.4.1A illustrates the anchor bolt spacing provisions in 4.4.1.6 and depicts the requirements of 4.4.6(3) regarding placement of anchor bolts at ends of plates. C 118 Figure C4.4.1A SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Anchor Bolt Placement Requirements For Wood Structural Panels Designed to Resist Combined Shear and Wind Uplift C4.4.1.7 Sheathing Splices: In multi-story applications where the upper story and lower story sheathing adjoin over a common horizontal framing member, the connection of the sheathing to the framing member can be designed to maintain a load path for tension and shear. It is recognized that wood is directly stressed in tension perpendicular to grain in some details; however, those cases are prescriptively permitted and also limited to nail size and spacing verified by testing. Splice panel orientation does not affect capacity of the sheathed tension splice joint and therefore panel orientation can be either parallel or perpendicular to studs. C4.4.1.7(1) Where sheathing edges from the upper and lower story meet over a common horizontal framing member, wood stressed in tension perpendicular to grain is relied upon directly to maintain load path for tension (Figure C4.4.1B). The location of sheathing splices need not occur at mid-height of the horizontal framing. Wall height, floor depth, available panel lengths, and maintaining minimum edge distances between sheathing nails and framing will influence the practical location of the sheathing splice in the horizontal framing member. Wood member stresses in this application are limited to that which can be developed with nail spacing to 3 in. o.c. (minimum) for a single-row and 6 in. o.c. (minimum) for a double-row at each panel edge based on results from testing. Limiting tension stresses perpendicular to grain in horizontal framing members is accomplished by limiting nail spacing to 3 in. o.c. (minimum) for a single-row and 6 in. o.c. (minimum) for a double-row. This limitation does not preclude use of more closely spaced nails where the horizontal framing member is an engineered rim board or similar product that can resist higher induced tension stresses perpendicular to grain. Follow manufacturers' recommendations for minimum nail spacing permitted for this application. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Figure C4.4.1.B Panel Splice Over Common Horizontal Framing Member 119 C4.4.2 Wood Structural Panels Used in Walls Designed to Resist Only Uplift from Wind Panels with a minimum thickness of 3/8 in. are permitted to be used in this application to resist uplift from wind only when panels are installed with the strength axis parallel to studs (see SDPWS 4.4.1 for provisions on resistance to combined shear and uplift from wind). Tabulated unit uplift capacities are applicable for wood structural panels with 3/8 in. and greater thickness. For applications where panel strength axis is oriented perpendicular to studs, manufacturer recommendations should be followed. Figure C4.4.1.C Detail for Continuous Panel Between Levels (Load Path for Shear Transfer Into and Out of the Diaphragm Not Shown) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS C4.4.1.7(2) The panel splice across studs detail in Figure 4I relies on increased nailing between vertical framing (e.g., studs) and sheathing to transfer tension forces while shear is transferred through nailed connections to horizontal framing such as horizontal blocking. This detail assumes no direct loading of framing members in tension perpendicular to grain for development of the tension load path. Additional nailing between sheathing and vertical framing on each side of the panel splice maintains load path for tension. Where the panel is continuous between stories, as shown in Figure 4I, one option to maintain load path for shear utilizes attachment of sheathing to wall plate framing as shown in Figure C4.4.1C. 120 EXAMPLE C4.4.1-1 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Calculate Nominal Uplift Capacity for Combined Uplift and Shear Case Calculate the nominal uplift capacity in SDPWS Table 4.4.1 for a wood structural panel shear wall constructed as follows: When subjected to combined shear and wind uplift forces, the calculation for nominal uplift capacity is based on the assumption that nails resist either shear or wind uplift forces. EXAMPLE C4.4.2-1 Calculate Nominal Uplift Capacity for Wind Uplift Only Case Calculate the nominal uplift capacity in SDPWS Table 4.4.2 for a wood structural panel sheathing over framing constructed as follows: Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 121 C4.5 Cross-Laminated Timber (CLT) Diaphragms teners are uniformly spaced at CLT panel edges, nominal unit shear capacity, νn, of the fasteners can be calculated as follows: C The design unit shear capacities for ASD and LRFD are calculated from the nominal unit shear capacity in accordance with 4.1.4. The foregoing is applicable only for the determination of the design unit shear capacity for the dowel-type fastener connections used to transfer diaphragm shear forces between CLT panels and between CLT panels and diaphragm boundary elements. For design of wood elements, steel parts, and chord splice connections of the diaphragm system, other than the dowel-type fasteners used to transfer diaphragm shear forces, design force increase factors are intended to ensure development of the targeted minimum levels of strength above that required by design for wind and seismic loads. Wood elements of the diaphragm system include CLT panels, framing used as chords and collectors, and wood splines. Steel parts of the diaphragm system include chords and collectors, steel splines, and straps and plates used as boundary element splices. The design force increase factor of 2.0 is applied to the forces induced by the diaphragm design loads for all wood elements, steel parts, and chord splice connections as a default with exceptions. The first exception allows use of a design force increase factor of 1.5 on diaphragm design wind loads for design of wood elements and wood splice connections. The second exception allows use of design force increase factors of 1.5 (for seismic) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS Requirements for the engineered design of CLT diaphragms using either ASD or LRFD (see 2.1.2) are based on principles of engineering mechanics with member and connection resistance in accordance with NDS (6). For stiffness, an adaptation of Equation C4.2.3-1 for CLT diaphragm deflection will typically replace wood structural panel stiffness properties and nail slip estimates with values for CLT diaphragms. See C-B.4 for calculation of CLT panel stiffness properties. Design loads, drift, deflection, and deformation requirements of the applicable building code or, in the absence of an applicable building code, ASCE 7 apply for the design of CLT diaphragms. The assumed structural model for the CLT diaphragm requirements follows the deep beam analogy where the CLT diaphragm chords are designed to resist all axial tension and compression forces (similar to flanges of a beam) and the CLT panels and their connections resist shear forces (similar to the web of a beam). The cumulative result of the proposed requirements is to target diaphragm shear strengths with a minimum margin above the required ASD design level of 2.0 for wind and 2.8 for seismic which is the same minimum margin above ASD design level that is associated with wood structural panel diaphragms of 4.2. To obtain the target diaphragm shear strength margins, requirements for in-plane diaphragm shear connections, including those at panel-to-panel connections and panel-to-boundary member connections, are required to utilize dowel-type fastener connection designs that calculate to have Mode IIIs or Mode IV yielding per NDS (6) to promote a ductile connection associated with wood bearing and fastener bending deformations. Mode III and Mode IV yielding behavior is present in nailed wood structural panel diaphragms of 4.2 and is associated with fastener bearing length in the main member that is adequate to develop the fastener bending yield limit state in the main member. Increased fastener bearing length in the main member is associated with improved ultimate load performance of individual fastener connections due to improved withdrawal resistance with greater penetrations. Ultimate failure for in-plane diaphragm shear connections at loads in excess of the diaphragm shear connection yield limit state may include withdrawal of the fastener from the wood, fastener head pull through the side member, wood failure such as splitting and row tear out, and fastener failure in tension or combined tension and bending. In typical applications where diaphragm shear fas- 122 SDPWS COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS and 1.0 (for wind) for chord splice connections which utilize dowel‐type fasteners calculated to have Mode IIIs or Mode IV yielding in recognition of the similarity of strength and stiffness in those connections when compared to the in‐plane diaphragm shear connections also limited to Mode IIIs or Mode IV yielding. As mentioned previously, the design force increase factor does not apply for the design of dowel-type fastener connections that establish the nominal unit shear capacity (see Eq. C4.51) (e.g., dowel-type fastener connections at splines for diaphragm shear transfer between adjacent CLT panel edges and dowel-type fastener connections between CLT panel edges and supporting elements for diaphragm shear transfer). Design force increase factors for wood elements (i.e., 2.0 for seismic and 1.5 for wind) are based on consideration of the target minimum strength margin for diaphragm shear for wind and seismic loads and wood strength limit states as follows: estimate of the average diaphragm shear strength margin and steel part yield stress limit states as follows: The design force increase factor for wood elements and wood splice connections resisting wind loads per SDPWS 4.5.4 (3) Exception 1 is based on the 1.5 factor derived for the wood strength limit states (see Equation C4.5-2). The design force increase factor for chord splice connections which utilize dowel‐type fasteners and that calculate to have Mode IIIs or Mode IV yielding (i.e., 1.5 for seismic and 1.0 for wind) per SDPWS 4.5.4 (3) Exception 2 is based on consideration of the estimated average diaphragm shear strength margin and the estimated average chord splice connection strength margin as follows: The design force increase factor for steel parts (i.e., 2.0 for seismic and wind) is based on consideration of an Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 123 The design force increase factor for chord splice connections which utilize dowel‐type fasteners that calculate to have Mode IIIs or Mode IV yielding of 1.0 is specified for wind design in SDPWS 4.5.4 (3) Exception 2. The design force increase factor of 1.5 is specified for seismic design in SDPWS 4.5.4 (3) Exception 2 to account for potential differences in strength and stiffness performance of diaphragm shear connections and diaphragm chord splice connections at force levels in excess of design seismic forces. The specified 1.5 design force increase factor for seismic is intended to a) protect against occurrence of large deformations in chord splice connections relative to diaphragm shear connections which could reduce effectiveness of diaphragm shear fasteners for shear resistance, and b) protect against potential for average strength margin in chord splice connections to be less than estimated which could reduce effectiveness of diaphragm shear fasteners for shear resistance and limit ability of the diaphragm to achieve the target minimum strength margin above design demand. C4.6 Cross-Laminated Timber (CLT) Shear Walls do not meet requirements of Appendix B, are alternatives subject to the approval of the authority having jurisdiction. Such alternatives, where used for seismic force resistance, are associated with a prescribed limitation on seismic design category, structural height, and seismic design coefficients unless other values are approved (per SDPWS 4.6.3.2 Exception). The Exception language is based on similar criteria for sheathed wood frame shear walls where sheathing is attached with adhesives; where the criteria address concerns related to brittle response as well as intent to set a conservative seismic design coefficients (i.e., R, Cd, and Ω0) if such systems are used in low to moderate seismic design categories. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL COMMENTARY: LATERAL FORCE-RESISTING SYSTEMS General requirements for cross-laminated timber (CLT) shear walls include consideration of shear wall deflection (discussed in 4.6.2) and strength (discussed in 4.6.3) and are predicated on using products that are in compliance with the product standards referenced in this Standard. Requirements for CLT shear walls are contained in Appendix B for two configurations of CLT shear walls that have been tested and evaluated for seismic force resistance: i) Cross Laminated Timber Shear Wall (CLT panel aspect ratio from 2:1 to 4:1) and ii) Cross Laminated Timber Shear Wall with Shear Resistance Provided by High Aspect Ratio Panels Only (CLT panel aspect ratio of 4:1). Other shear walls utilizing CLT C 124 SDPWS COMMENTARY: APPENDIX B This page is intentionally left blank. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 125 Commentary to Appendix B C-B.1 Scope C-B.2 Application Requirements The CLT shear wall lateral force-resisting system (LFRS) is intended for use in platform construction where all individual wall panels are single-story clearheight panels and the CLT floor panels are designed as the floor diaphragm. Elements of the gravity framing system can include but need not be limited to CLT walls, beams and columns, and light-frame walls. The required use of the CLT shear wall LFRS in platform construc- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY TO APPENDIX B Requirements for CLT shear walls are based on research that demonstrates adequate adjusted collapse margin ratios using the FEMA P695 methodology (66, 79). CLT shear wall design requirements are intended to produce yielding of nails and metal connectors at CLT panel edges, and combined rocking and sliding behavior of individual wall panels prior to occurrence of the ultimate shear wall strength limit state associated with nailed connection failure. CLT shear walls can be in single panel or multi-panel configurations. Design unit shears are associated with uniform spacing of prescribed connectors at the bottom of the panel, top of the panel and at vertical edges of multi-panel shear walls. Typical single panel and multi-panel wall configurations are shown in Figure C-B.1 and examples of typical connection details are depicted in Table C-B.2. While angle connectors at top and bottom are shown on one face of the CLT wall panel only, it is permissible to place connectors on both faces and for the minimum requirement of two connectors per panel to be on opposite faces of the CLT wall panel. Multi-panel shear walls are formed by individual panels having the same aspect ratio to promote deformation compatibility within the shear wall. The design and detailing requirements produce yielding of the prescribed nailed connections and rocking behavior in the shear wall as depicted in Figure C-B.2 when subjected to in-plane shear forces. Details of Table C-B.2 do not incorporate concrete floor toppings for clarity of illustrating connector requirements for in-plane shear loading and added fastening for out-ofplane loads. A clear space should be provided between such toppings and the vertical and horizontal legs of the connector to avoid inhibiting connector deformation (e.g., bending, tension and rotation) under in-plane shear loading of the shear wall. tion precludes application for balloon frame construction associated with multi-story clear-height wall panels. For gable end wall conditions, the requirement for wall panels of the same height necessitates a configuration of wall panels of the same height in the story below the gable end while the “triangular” gable end wall portion can be composed of CLT wall panels or other elements designed as the collector. The design method requires similar detailing (i.e., minimum panel aspect ratio and shear connections) for all CLT wall panels, whether part of the designated lateral force-resisting system or not, to promote deformation compatibility with the CLT shear wall system up to the point of failure. CLT wall panels that are not part of the designated lateral force-resisting system are expected to be present in addition to the CLT shear walls designated as the vertical elements of the lateral force-resisting system. In general, such added wall elements are considered to reduce in-plane shear demands on the LFRS and improve the strength and stiffness of the building as a whole, much like the presence of sheathed walls in excess of the designed shear walls in a sheathed woodframe shear wall structure. However, such added wall elements may produce adverse effects on the structural system response that must also be considered in design of the structural system, including but not limited to the distribution of forces and load path to elements of the structural system, which may require strengthening relative to a design that does not account for the interaction with CLT wall panels that are not designated as shear walls. In addition, consideration must be given to the potential for CLT wall panels not designated as shear walls to create structural irregularities such as a weak story irregularity, torsional irregularity, in-plane discontinuity in vertical lateral force-resisting element irregularity, and out-ofplane offset irregularity. A suggested method for evaluating the structure for the presence of ASCE 7 structural irregularities involves consideration of two separate cases representing bounding values of strength and stiffness contributed by the CLT panels that are not part of the designated seismic force resisting system (SFRS): (1) considering elements that are part of the designated SFRS alone, and (2) considering elements not part of the designated SFRS in combination with the elements that are part of the designated SFRS. Per this method, the bounding values of strength for CLT panels that are designated as not part 126 SDPWS COMMENTARY: APPENDIX B of the SFRS range from a minimum of zero in Case 1 to a maximum equal to shear wall strength associated with full overturning restraint in Case 2. For some structural irregularities, placement criteria, rather than structural distribution of strength and stiffness, can trigger an irregularity (e.g., out-of-plane offset, in-plane discontinuity and non-parallel system irregularity). Such irregulari- ties can be triggered for CLT wall panels whether part of the designated SFRS or not part of the designated SFRS. Figure C-B.1 Typical Shear Wall for a) Single Panel Configuration, and b) Multi-panel Configuration CLT wall panels with the prescribed nailed connectors are expected to contribute strength and stiffness over the full range of displacement expected of the CLT shear walls as seen in testing results of CLT shear walls with similar nailed connectors with and without hold-downs (65). The extent to which CLT wall panels that are not part of the designated LFRS add strength and stiffness depends on the level of overturning restraint provided to the individual wall panels through dead load and overturning restraint by surrounding elements. The design requirements conservatively prescribe that the strength and stiffness contribution of such walls, for purposes of determining their adverse effect on the structural system, be taken as equal to a shear wall with full overturning restraint provided at wall ends. It is recognized that alterna- tive design approaches may entail detailing of CLT wall panels to either isolate them from resisting in-plane shear forces or to minimize their resistance to in-plane shear forces (such as through use of slotted holes to promote sliding, rocking, or both) while also providing equivalent deformation capacity to CLT wall panels with the prescribed in-plane shear connections. Where such alternative approaches are used, effects of the alternative design for CLT wall panels that are not part of the LFRS (including those associated with strength and stiffness of the alternative design elements) must be considered in the design of the structural system. Loads are distributed to shear walls within the wall line based on the stiffness determined using SDPWS Equation B-1 for each shear wall within the wall line. For Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC distribution of shear to vertical elements of the LFRS, a diaphragm can be idealized as flexible, idealized as rigid, or modeled as semi-rigid in accordance with the requirements of the ASCE 7 12.3 and SDPWS 4.1.7. C-B.3 CLT Shear Wall Requirements equivalent shear capacity to that of the angle connectors at the top and bottom of the CLT shear wall. The prescribed connectors have been tested both as part of a shear wall and as individual components under uplift loading and shear loading. Testing employed bolts in the horizontal leg of the connectors. Lag screws are prescribed as an alternative with strength in shear and uplift capable of developing the tested strength of the nailed connector. Design of CLT shear walls and associated load paths is in accordance with the basic load combinations of ASCE 7 (load combinations without overstrength) except where otherwise required by this standard. Hold-down requirements are intended for two common hold-down systems – continuous tie-rod systems and conventional hold-down devices. For both, the required design for 2 times the forces associated with the design unit shear capacity of the CLT shear wall is consistent with level of overstrength in the hold-down system in CLT shear wall testing and is intended to ensure shear strength in excess of the specified nominal strength of the shear connections can be developed. A device elongation limit of 0.185 inches for strength design is required to be met at each story level to avoid concentration of device elongation in one level and is based on consideration of ICCES evaluation criteria limits for conventional hold-down devices attached to wood members and continuous rod tie-down systems used to resist wind uplift in light-frame wood walls (82, 83). Figure C-B.2 Rotation of Individual Panels in a CLT Shear Wall Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY TO APPENDIX B CLT shear wall requirements include use of CLT panels of prescribed aspect ratios; use of prescribed nailed connectors at bottoms of panels, tops of panels, and adjoining vertical edge(s) of multi-panel shear walls; a minimum required capacity for overturning tension devices; and compression zone length requirements. The prescribed angle connectors at the top and bottom of panels and nailed plate connectors at the adjoining vertical edge of multi-panel shear walls have been evaluated under fully-reversed cyclic testing of shear walls and should not be modified or substituted without verification of equivalent shear wall performance by cyclic testing of shear walls that evaluates simultaneous uplift and shear loading of the connectors. For the prescribed angle connector, observed failure from shear wall testing was due to combined nail bending, nail withdrawal from the wood, and limited occurrence of combined bending/tension failure of the nail, without metal connector failure. The prescribed connectors for the vertical edge provide 127 128 Figure C-B.3 SDPWS COMMENTARY: APPENDIX B Combined Shear and Gravity Loading and Geometry for CLT Shear Wall Composed of Multiple CLT Panels (e.g., Multi-panel Shear Wall), a) Compression End and Tension End Panel Circled, and b) Illustration of Individual CLT Panel Overturning and Opposing Internal Shears at Adjacent Vertical Edges Due to In-plane Unit Shear Loading Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC For the compression end panel depicted in Figure C-B.3, the compression force from summation of moment about O is: The compression force associated with the length of the compression zone, assuming a uniform stress distribution (i.e., rectangular stress distribution) in the compression zone, is determined by the following equations: C COMMENTARY TO APPENDIX B Under in-plane unit shear loading, individual CLT panels within a CLT shear wall designed and detailed in accordance with Appendix B will rotate as shown in Figure C-B.2. For purposes of determining tension force, T, and compression force, C, static equilibrium is based on consideration of the tension end panel and compression end panel depicted in Figure C-B.3. Consistent with individual panel rotation behavior as opposed to overturning as a rigid body whole, the static analysis of individual panels is employed in determination of T and C forces. The contribution of dead load in the overturning design is specifically limited to only that dead load tributary to the individual panel and to elements aligned directly above the panel of interest per Figure C-B.3. The dead load includes reactions from headers, beams, and similar elements when they are supported by the panel of interest. Vertical load reactions from floors above are to be applied to each panel of interest as C and T reactions for end panels and C reactions for interior panels, as applicable. As a result of this assumption of individual panel overturning, the overturning induced tension force is larger and overturning induced compression force is smaller than T and C forces associated with overturning the wall as a rigid monolith, primarily because the static analysis does not assume distributed gravity loading over the length of the wall can be mobilized via a whole-wall rigid body assumption to reduce the T force or increase the C force. For the tension end panel depicted in Figure C-B.3, the tension force from summation of moment about point O is: 129 The bearing resistance in Equation C-B.4 is based on the compression perpendicular to grain stress associated with the CLT floor panel or wood bottom plate supporting the wall. The bearing resistance in Equation C-B.5 is based on the design axial stress associated with the CLT wall panel parallel to grain layers and is applicable where designed compression zone elements are used to transfer Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 130 SDPWS COMMENTARY: APPENDIX B such forces as opposed to being limited by compression perpendicular to grain bearing stress in the floor panel. The designed compression zone force transfer detail through the floor panel is likely to be used in cases with a combination of high axial compression loads and high aspect ratio panels for the purpose of limiting wall thickness increases associated with meeting compression zone length requirements. The length of the uniform stress compression zone, x, to satisfy static equilibrium is determined by substitution of Equation C-B.4 or C-B.5 into Equation C-B.3 and solving for x. The solution for x limited by bearing stress perpendicular to grain is provided in Equation C-B.6. Where the length of the compression zone, x, is smaller than the length of the compression end panel, bs, a positive value under the root in Equation C-B.6 is produced and the resulting value of x can be used to determine a precise value of compression force, C, in accordance with Equation C-B.3. A negative value under the root of Equation C-B.6 signifies the compression zone is not contained within the compression end panel. A preliminary check for whether adequate compression panel length is provided under unit shear loading alone (e.g., w = CT = 0) can be obtained from Equation C-B.7. When Equation C-B.7 is not satisfied, a negative root will occur in Equation C-B.6 indicating inadequate compression panel length. The loading and geometry depicted in Figure C-B.3 for tension end and compression end panels are for purposes of illustrating a method to calculate an appropriate T and C force for the system. Testing shows rotation of the compression end panel is primarily about the outermost edge of the compression end panel – not about the centroid of the calculated compression zone. As such, using the loading and geometry depicted in Figure C-B.3 for the compression end panel will underestimate the moment arm and overestimate vertical edge forces when summing forces vertically at that location. Results of such analysis should not be used to modify required ver- tical connector spacing in accordance with SDPWS B.3.3 which requires the same average vertical connector spacing with rounding as used for the top and bottom edges of the CLT shear wall. The required number of connections at vertical and horizontal edges (i.e., the same average spacing) provides balanced vertical and horizontal shear and enables the intended rotation behavior of individual panels of a multi-panel shear wall when subjected to inplane unit shear loading. C-B.3.6 Other Load Path Connections to CLT Load path connections to CLT wall panels occur in addition to those of the designated lateral force-resisting system for in-plane shear resistance and include connections for out-of-plane wind and seismic forces and general structural integrity. These additional load path connections include attachment of wall panels to elements above and below for out-of-plane forces, interconnection of walls at intersections, and attachment of conventional hold-down devices at wall ends. The combined requirement for fastener yielding per Mode IIIs or IV and compliance with NDS Appendix E ensures that added fastening provides a predictable yielding mechanism with levels of overstrength similar to that provided by the prescribed connections for in-plane shear resistance. Connections at the top and bottom of wall for resistance to out-of-plane forces are in addition to prescribed angle connectors which do not have an established design value for loads perpendicular to the plane of the wall. Connections at the top and bottom of wall meeting requirements for yielding in Mode IIIs or IV are considered beneficial to in-plane shear wall strength and stiffness, which is already governed by nail yielding, without degrading peak load and post-peak response of the prescribed shear wall connectors. To address the potential for excessive screw (e.g., wood screw and lag screw) attachment to inhibit the rocking mechanism of the CLT panel due to high axial stiffness and strength of screws loaded in withdrawal, screw attachment of top and bottom of wall connections to supporting elements is not permitted. Screws used in these locations are considered an alternative to the prescribed smooth shank dowel fasteners (see Table C-B.2 Typical connection details) at the top and bottom of wall locations and are subject to approval by the authority having jurisdiction. Typical fastening will employ smooth shank nails or pins to resist out-of-plane forces. Details for anchoring the top and bottom of walls for outof-plane forces are not specifically prescribed to enable varying design options for meeting out-of-plane anchor- Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC C-B.3.7 CLT Shear Walls with Shear Resistance Provided by High Aspect Ratio Panels Only CLT shear walls with shear resistance provided by high aspect ratio panels only is a specific configuration of the CLT shear wall system where high aspect ratio is defined as wall panel height to wall panel length ratio of 4. Minor variations in actual panel aspect ratio of +/2.5 percent are permissible such that actual panel aspect ratio range is 3.9 to 4.1. All requirements applicable for CLT shear walls are also applicable and additionally only CLT panels with aspect ratio of 4 are permissible as part of the designated shear wall system. CLT wall panels of equal or greater aspect ratio are permissible when not used as part of the designated shear wall system to promote deformation compatibility of CLT wall panels that are not designated as shear walls. Where the system used is “CLT shear walls with shear resistance provided by high aspect ratio panels only”, it is required that the aspect ratio requirement be met in all shear walls. While 131 this limitation can be accommodated in single story and multi-story construction with equal story height it may not be practical to implement where story height varies. In such cases, use of CLT shear walls with a permissible range in aspect ratio from 2 to 4 should be considered. C-B.4 Shear Wall Deflection The CLT shear wall deflection equation incorporates four primary components: individual wall panel bending, individual wall panel shear, sliding, and rigid body overturning. Individual panel rotation is included for multipanel configurations. The deflection method accounts for the difference in observed stiffness of single and multipanel CLT shear walls tested as well as influence of individual panel aspect ratio on shear wall deflection. The equation does not account for potential stiffening effects of boundary elements such as intersecting wall, floor, and roof elements. Components of shear wall deflection are depicted in Figure C-B.4. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY TO APPENDIX B Figure C-B.4 Shear Wall Deflection Components Due to Panel Bending and Shear, Sliding Due to Fastener Slip, Rotation due to Fastener Slip at Vertical Edge Connections, and Rigid Body Rotation 132 SDPWS COMMENTARY: APPENDIX B The panel shear deformation term utilizes inplane shear stiffness, GAeff (in-plane), in units of pounds per inch (lb/in). Example values of GAeff (in-plane) provided in Table C-B.1 are calculated in accordance with Flaig M. and Blass H. (64) per Equation C-B.10 and Equation C-B.11. An alternative formulation for (EI)eff for a 5-layer panel with equal thickness layers is adapted from Blass and Fellmoser (63), see Equation C-B.9: Figure C-B.5 Illustration of a1, a3, and a5 for a 5-layer panel Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table C-B.1 133 Example GAeff (in-plane) for in-plane shear1 The sliding term, V(nail load)/(135,000 D1.5), addresses sources of deformation in the connector including nails and bolts. The slip constant takes into account loading perpendicular to the grain in the nailed connection. The single nail diameter of 0.135 in. used for all the connectors in this study, allows the use of a simplified nail slip term, V(nail load)/(6700). The deflection equation also explicitly breaks out sliding from multi-panel rotation due to vertical connection slip. If there is no vertical edge connection, then vertical connection slip equals 0 inches. The final term in the deflection equation represents rigid body rotation about the compression toe of the shear wall and is the same as used for sheathed wood-frame shear walls. Vertical deformation of the wall hold-down system, Δa, is based on the induced overturning forces and includes sources of deflection such as fastener slip, device elongation, rod elongation, uncompensated shrinkage, and vertical compression deformation. C COMMENTARY TO APPENDIX B Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 134 Table C-B.2 SDPWS COMMENTARY: APPENDIX B Typical Connection Details Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table C-B.2 135 Typical Connection Details (continued) C COMMENTARY TO APPENDIX B Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 136 Table C-B.2 SDPWS COMMENTARY: APPENDIX B Typical Connection Details (continued) Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC Table C-B.2 137 Typical Connection Details (continued) C COMMENTARY TO APPENDIX B Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL 138 SDPWS COMMENTARY: REFERENCES This page is intentionally left blank. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 139 COMMENTARY REFERENCES 1. ASTM Standard D 6555-17, Standard Guide for Evaluating System Effects in Repetitive-Member Wood Assemblies, ASTM, West Conshohocken, PA, 2017. 12. Ryan, T. J., K. J. Fridley, D. G. Pollock, and R. Y. Itani, Inter-Story Shear Transfer in Woodframe Buildings: Final Report, Washington State University, Pullman, WA, 2001. 2. 2006 International Building Code (IBC), International Code Council, Washington, DC, 2006. 13. Sugiyama, Hideo, 1981, The Evaluation of Shear Strength of Plywood-Sheathed Walls with Openings, Mokuzai Kogyo (Wood Industry) 36-7, 1981. 3. Laboratory Report 55, Lateral Tests on Plywood Sheathed Diaphragms (out of print), Douglas Fir Plywood Association (now APA-The Engineered Wood Association), Tacoma, WA, 1952. 4. Laboratory Report 63a, 1954 Horizontal Plywood Diaphragm Tests (out of print), Douglas Fir Plywood Association (now APA-The Engineered Wood Association), Tacoma, WA, 1955. 5. Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers, ASCE/SEI Standard 7-16. Reston, VA, 2016. 7. NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures and Commentary, FEMA Report 450-1 and 2, 2003 Edition, Washington, DC, 2004. 8. PS2-18, Performance Standard for Wood-Based Structural-Use Panels, U.S. Department of Commerce, National Institute of Standards and Technology, Gaithersburg, MD, 2018. 9. Polensek, Anton. Rational Design Procedure for Wood-Stud Walls Under Bending and Compression, Wood Science, July 1976. 15. Wood Structural Panel Shear Walls with Gypsum Wallboard and Window/Door Openings, APA 157, APA- The Engineered Wood Association, Tacoma, WA, 1996. 16. ASTM Standard D 5457-20, Standard Specification for Computing Reference Resistance of Wood- Based Materials and Structural Connections for Load and Resistance Factor Design, ASTM, West Conshohocken, PA, 2020. 17. Racking Load Tests for the American Fiberboard Association, PFS Test Report #96-60, Madison, WI, 1996. 18. Wood Structural Panel Shear Walls, Research Report 154, APA-The Engineered Wood Association, Tacoma, WA, 1999. 19. Plywood Diaphragms, Research Report 138, APA The Engineered Wood Association, Tacoma, WA, 1990. 20. 2021 International Building Code (IBC), International Code Council, Washington, DC, 2021 10. Racking Load Tests for the American Fiberboard Association and the American Hardboard Association, PFS Test Report #01-25, Madison, WI, 2001. 21. Luxford, R. F. and W. E. Bonser, Adequacy of Light Frame Wall Construction, No. 2137, Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, 1958. 11. Report 106, 1966 Horizontal Plywood Diaphragm Tests (out of print), Douglas Fir Plywood Association (now APA-The Engineered Wood Association), APA, Tacoma, WA, 1966. 22. Shear Wall Lumber Framing: 2x’s vs. Single 3x’s at Adjoining Panel Edges, APA Report T200322, APA-The Engineered Wood Association, Tacoma, WA, 2003. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: REFERENCES 6. National Design Specification (NDS) for Wood Construction, ANSI/AWC NDS 2018, American Wood Council, Leesburg, VA, 2017. 14. Using Narrow Pieces of Wood Structural Panel Sheathing in Wood Shear Walls, APA T2005-08, APA- The Engineered Wood Association, Tacoma, WA, 2005. 140 SDPWS COMMENTARY: REFERENCES 23. Racking Strengths and Stiffnesses of Exterior and Interior Frame Wall Constructions for Department of Housing and Urban Development, Washington, D.C., NAHB Research Foundation, Inc., May, 1971. 24. The Rigidity and Strength of Frame Walls, No. 896, Madison, WI, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, March 1956. 25. Rosowsky, D., L. Elkins, and C. Carroll, Cyclic Tests of Engineered Shear Walls Considering Different Plate Washer Sizes, Oregon State University, Corvallis, OR, 2004. 26. Stillinger, J.R., Lateral Tests on Full-scale Lumber- sheathed Roof Diaphragms, Report No.T-6, Oregon State University, Corvallis, OR, 1953. 27. Ni, C. and E. Karacabeyli, Effect of Blocking in Horizontally Sheathed Shear Walls, Wood Design Focus, Forest Products Society, Volume 12, Number 2, Summer, 2002. 28. Mi, H., C. Ni, Y. H. Chui, and E. Karacabeyli, Racking Performance of Tall Unblocked Shear Walls, ASCE Journal of Structural Engineering, Volume 132, Number 1, 145-152, 2006. 29. Cyclic Testing of Fiberboard Shear Walls with Varying Aspect Ratios, NAHB Research Center, Upper Marlboro, MD, 2006. 30. Gupta, R., H. Redler, and M. Clauson, Cyclic Tests of Engineered Shear Walls Considering Different Plate Washer Sizes (Phase II), Oregon State University, Corvallis, OR, 2007. 31. Schmid, B. Proposal S98. International Code Council Proposed Changes to the 2006 International Building Code, Volume I, Country Club Hills, IL, June 2006 32. Shear Capacity of Continuous Joints in HighLoad Diaphragms, APA Report T2001L-72, Tacoma, WA, 2001. 33. Line, P., N. Waltz, and T. Skaggs, Seismic Equivalence Parameters for Engineered Wood-frame Wood Structural Panel Shear Walls, Wood Design Focus, July 2008. 34. ASTM E 2126-19, Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Walls for Buildings. ASTM International, West Conshohocken, PA, 2019. 35. Salenikovich, A. J. and J. D. Dolan, Racking Performance of Shear Walls with Various Aspect Ratios: Part I - Monotonic Tests of Fully Anchored Walls. Forest Products Journal, 53(10): 65-73, Forest Products Society, Madison, WI, 2003. 36. Salenikovich, A. J. and J. D. Dolan, Racking Performance of Shear Walls with Various Aspect Ratios: Part II - Cyclic Tests of Fully Anchored Walls. Forest Products Journal, 53(10), Forest Products Society, Madison, WI, 2003. 37. Krawinkler, H., F. Parisi, L. Ibarra, A. Ayoub, and R. Medina, Development of a Testing Protocol for Wood Frame Structures, CUREE Publication No. W-02, 2000. 38. Filiatrault, A. and R. O. Foschi, Static and Dynamic Tests of Timber Shear Walls Fastened with Nails and Wood Adhesive. Canadian Journal of Civil Engineering 18: 749-755. 1991. 39. Combined Shear and Wind Uplift Tests on 7/16inch Oriented Strand Board Panels, APA-The Engineered Wood Association, Tacoma, WA, May, 2007. 40. Combined Shear and Wind Uplift Tests with 10d Common Nails, APA-The Engineered Wood Association, Tacoma, WA, March, 2008. 41. ASTM E 72-15 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction. ASTM International, West Conshohocken, PA, 2015. 42. Preliminary Perforated Shear Wall Testing. APA Report T2005-83. APA-The Engineered Wood Association, Tacoma, WA, 2005. 43. Dolan, J. D. and A. C. Johnson, Monotonic Tests of Long Shear Walls with Openings, Report No. TE-1996-001, Virginia Tech, Brooks Forest Products Research Center, Blacksburg, VA, 1997. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL SPECIAL DESIGN PROVISONS FOR WIND AND SEISMIC 44. Dolan, J. D. and A. C. Johnson, Monotonic Tests of Long Shear Walls with Openings, Report No. TE-1996-002, Virginia Tech, Brooks Forest Products Research Center, Blacksburg, VA, 1997. 45. Preliminary Perforated Shear Wall Testing, Report T2005-83, APA-The Engineered Wood Association, Tacoma, WA, December, 2005. 46. Nosse, John. Technical Activities. Building Standards, November/December 1975. 47. Sheedy, Paul. Anchorage of Concrete and Masonry Walls. Building Standards, September/October 1983. 48. Guidelines for Seismic Evaluation and Rehabilitation of Tilt-Up Buildings and Other Rigid Wall/ Flexible Diaphragm Structures, Structural Engineers Association of Northern California, 2001. 50. Uniform Building Code (UBC) 1976, International Conference of Building Officials now International Code Council, Washington, DC, 1976. 51. Yeh, Borjen and Keith, Ed, Using Wood Structural Panels for Shear and Wind Uplift Applications, 2010 World Conference on Timber Engineering. 52. APA – The Engineered Wood Association. Design for Combined Shear and Uplift from Wind, APA System Report SR-101. Tacoma, WA, 2010. 53. Evaluation of Force Transfer Around Openings – Experimental and Analytical Studies, APA M410, APA-The Engineered Wood Association, 2011. 54. Martin, Z.A. 2005. Design of Wood Structural Panel Shear Walls with Openings. A Comparison of Methods. Wood Design Focus. 15(1):18-20. 55. Breyer, D.E., K.J. Fridley, K.E. Cobeen and D.G. Pollock. 2015. Design of Wood Structures ASD/ LRFD, 7th ed, McGraw Hill, New York, NY. 56. SEAOC. 2012. 2009 IBC Structural/Seismic Design Manual, Volume 2: Building Design Examples for Light-frame, Tilt-up Masonry. Structural Engineers Association of California, Sacramento, CA. 57. Contribution of Gypsum Wallboard to Racking Resistance of Light-Frame Walls, Research Paper FPL 439, Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, December 1993. 58. PS 1-19 Structural Plywood, United States Department of Commerce, National Institute of Standards and Technology, Gaithersburg, MD, 2019. 59. ASTM F 1667-18a, Standard Specification for Driven Fasteners: Nails, Spikes, and Staples, ASTM, West Conshohocken, PA, 2018. 60. Panel Design Specification (PDS)-2020, APAThe Engineered Wood Association, Tacoma, WA, 2020. 61. ASTM Standard A653-10, Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process, ASTM, West Conshohocken, PA, 2010. 62. ANSI/ASME Standard B18.2.1-2012, Square, Hex, Heavy Hex, and Askew Head Bolts and Hex, Heavy Hex, Hex Flange, Lobed Head, and Lag Screws (Inch Series), American Society of Mechanical Engineers, New York, NY, 2012. 63. Blass and Fellmoser (2004). Design of solid wood panels with cross layers. In 8th world conference on timber engineering (Vol. 14, No. 17.6, p. 2004). 64. Flaig M. and Blass H (2013). Shear strength and shear stiffness of CLT-beams loaded in plane. CIB-W18 Meeting 46, Vancouver, Canada, 2013, Paper 46-12-3. Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL C COMMENTARY: REFERENCES 49. NIST GCR 14-917-32. NEHRP Seismic Design Technical Brief No. 10 – Seismic Design of Wood Light-Frame Structural Diaphragm Systems, A Guide for Practicing Engineers. September 2014. 141 142 SDPWS COMMENTARY: REFERENCES 65. FPInnovations (2013). US CLT Handbook, Special Publication SP-529E. Pointe-Claire, QC, Canada. 66. van de Lindt, J., Rammer, D., Amini, M. O., Line, P., Pei, S., and Popovski, M. (2021) “Determination of Seismic Performance Factors for Cross-Laminated Timber Shear Walls Based on the FEMA P695 Methodology.” General Technical Report FPL-GTR-281, Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, (In press). 67. Bendsten, B. A. and W. L. Galligan, Mean and Tolerance Limit Stresses and Stress Modeling for Compression Perpendicular to Grain in Hardwood and Softwood Species, Research Paper FPL 337, Madison, WI, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, 1979. 68. FEMA P695: Quantification of Building Seismic Performance Factors, Federal Emergency Management Agency, Washington, D.C., 2009. 69. Jayamon, J., Line, P., and Charney, F.: Sensitivity of Wood-Frame Shear Wall Collapse Performance to Variations in Hysteric Model Parameters, Journal of Structural Engineering, 145(1): 04018236, 2019. 70. Perry, L., Line, P., and Charney, F.: Influence of varying strength, from story to story, on modeled seismic response of wood-frame shear wall structures. WCTE 2018. 74. Preliminary Testing of Wood Structural Panel Shear Walls Under Cyclic (Reversed) Loading, Report 158, APA-The Engineered Wood Association, Tacoma, WA, 1998. 75. Line, P., D. Hohbach, and N. Waltz. “In-Plane Racking Strength Tests of Wood-frame Wood Structural Panel Shear Walls Using 10d “Short” Nails,” Proceedings of SEAOC Conference, 2020. 76. Line, P., D. Hohbach, and N. Waltz. “In-Plane Racking Strength Tests of Wood-frame Wood Structural Panel Shear Walls with 2-inch Panel Edge Nail Spacing and Representative MultiStory Details,” Proceedings of SEAOC Conference, 2019. 77. Raised-Heel Trusses for Efficient, Cost-Effective, Comfortable Homes, APA R330, APA-The Engineered Wood Association, 2016. 78. Use of Wood Structural Panels for Energy-Heel Trusses, APA SR-103A, APA-The Engineered Wood Association, 2014. 79. NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, Volume 1: Part 1 Provisions, Part 2 Commentary, FEMA P 2082-1, September 2020, Washington, DC, 2020. 80. Martin, ZA Skaggs, TD, Shear wall deflection and predictive equations, APA Report T2001L-65, 2002. 71. Line, P., Charney, F., Linville, J.: Influence of story lateral strength profile on modeled seismic response of wood-frame shear wall buildings. WCTE 2020. 81. Line, P., Hohbach, D., Waltz, N.: Gypsum Wallboard Finish Contribution to the Racking Strength of Wood-Frame Shear Walls with Representative Multi-Story Details. WCTE 2020. 72. 2018 IBC SEAOC Seismic/Structural Design Manual, Vol 2. Structural Engineers Association of California, Sacramento, California. 82. ICC-ES AC155 - Acceptance Criteria for HoldDowns (Tie-Downs) Attached to Wood Members, International Code Council Evaluation Service, Brea, CA, 92821. 73. A Mechanics-Based Approach for Determining Deflection of Stacked Multi-Storey Wood-Based Shear Walls, FPInnovations and the Canadian Wood Council. 83. ICC-ES AC391 – Acceptance Criteria for Continuous Rod Tie-Down Runs and Continuous Rod Tie-Down Systems Used to Resist Wind Uplift, International Code Council Evaluation Service, Brea, CA, 92821 Copyright 2020 © American Wood Council. Downloaded/printed pursuant to License Agreement. No reproduction or transfer authorized. AMERICAN WOOD COUNCIL American Wood Council 222 Catoctin Circle SE, Suite 201 Leesburg, VA 20175 www.awc.org info@awc.org $60.00 ISBN 978-1-940383-14-9 56000> 9 781940 383149
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )