Site layout proposal General 1 2 3 4 C-1 A-1 AL-1 AD-1 Cover sheet. Table of contents Site layout Site requirements / Equipment legend Schematic cross section(s) Site layout approval: 11-07-2023 Rev Date VMI KTH Proposal Drw Chk Proj. phase Description Cover sheet Table of contents 0 Sheet Subject Revision history H G F E D C B A YE-23-00003 Typical configuration shown (not site specific) Taiz, Yemen CathLab Room Subject Azurion 3 F15 CardioVascular Center - Taiz Type Project Sheet Drawing Important notes Signature customer The information in this package is provided as a customer convenience, and is not to be construed as architectural drawings or construction documents. Philips assumes no liability nor offers any warranty for the fitness or adequacy of the premises or the utilities available at the premises in which the equipment is to be installed, used or stored. Signature project manager Philips contact Mr. A. Mahir Sadi, +971 55 1003732, abdul.khalek.sadi@philips.com Philips Healthcare Customer ID Technical ID A3 A business of Royal Philips N.V. Philips Medical Systems Nederland B.V. Business Center EMEA Veenpluis 4-6, 5684 PC, Best, The Netherlands THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C-1 AND SHOULD NOT BE SEPARATED Quote No Order No © Koninklijke Philips Electronics N.V. 2020 All rights reserved. Reproduction in whole or in part is prohibited without prior written consent of the copyright holder. Table of contents mm C-1 Sheet 1/4 0 1 2 3 5m 4 1m Dimension origin at finished wall, near floor level. (6550) 1.2 (3460) (3460) Y 3200 1.9 1.8 1.3 1.4 1.1 4.2 Examination area CathLab Room Control area 2300 2.4 2.5 3.3 3.2 3.4 3.6 4.3 2.6 2.2 1.6 4.2 1 Wall connection box transmiter (WCBT) Workstation Hemo Control room To be decided by customer Dimensioning legend Existing doors/walls to be removed Beams or other building construction elements Columns (materials and strength unknown) XYZ System position dimension (ISO-centre) (XYZ) Architectural dimension to be checked on site Preferred service area THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C-1 AND SHOULD NOT BE SEPARATED Dimension from origin A3 Quote No Order No Technical ID New walls 11-07-2023 VMI Walls YE-23-00003 0 Legend Site layout 1.5 Technical area UPS Room Sheet Subject 1.7 3.5 Project 4.1 Taiz, Yemen CathLab Room 3.7 X (4500) (4500) 3.1 Drawing © Koninklijke Philips Electronics N.V. 2020 All rights reserved. Reproduction in whole or in part is prohibited without prior written consent of the copyright holder. 2.1 Azurion 3 F15 CardioVascular Center - Taiz 2.3 1 : 50 mm A-1 Sheet 2/4 · The equipment proposed in this room layout produces X-ray radiation. It is the customer's responsibility to comply with the local regulation. Normally X-ray shielding has to be applied to avoid hazards to patients, visitors and staff. Consult the Philips contact for details and support. Remote service diagnostics To establish this feature, a RJ45 type Ethernet connector must be installed with access to the customer's network (10/100/1000 Mbps). Environmental requirements Operating temperature range is 15°C - 28°C. at 20%-80% relative humidity (non-condensing). In case of UPS/Battery in the technical room, operating temperature must be 15 - 25°C. Azurion 3 F15 Resp No Description Mass [kg] Examination Area (Basic system excluding options) Heat Noise [W] [dB(A)] 1600 45-60 A 1.1 Patient table (AD7 swivel and tilt) 450 - - A 1.2 Clea floor (FD15) 1160 - - C 1.3 Monitor ceiling suspension 3 Fold 206 - - A 1.4 Auxiliary connection box 3 - - C 1.5 Fixed column 800mm 22 - - A 1.6 Examination Lamp mounted on fixed column 14 - - A 1.7 Radiation shield mounted on fixed column 20 - - A 1.8 Table mounted radiation shield 30 - - A 1.9 Injector Medrad Mark 7 Arterion 82 1200 - 570 <50 Control Area (Basic system excluding options) A 2.1 Operating station Basic 2x 24" Monitor 52 - - B 2.2 Table top - - - A 2.3 Firewall Cisco ASA-5506 - - - A 2.4 DVD Writer - - - A 2.5 Intercom - - - A 2.6 Workstation Hemo Control room 38 300 - 3700 68 Technical Area (Basic system excluding options) A 3.1 Main cabinet with Cabinet Rear Cover Deep 375 - - A 3.2 Peripheral cabinet with Cabinet Rear cover 200 - - A 3.3 Generator cabinet with Cabinet Rear cover 145 - - A 3.4 Documentation cabinet (trolley) 80 - - B 3.5 Mains switch - - - B 3.6 Earth reference terminal - - - A 3.7 Isolation transformer Hemo - - - B 4.1 Lead glass window - - - B 4.2 X-ray ON warning light - - - A 4.3 Wall connection box transmitter (WCBT) 5 10 - THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C-1 AND SHOULD NOT BE SEPARATED Quote No Order No Technical ID 11-07-2023 VMI YE-23-00003 Responsibilities A Delivered and installed by Philips B Delivered and installed by customer/contractor C (Pre) Delivered by Philips, installed by customer D (Pre) Delivered by customer and installed by Philips E Existing Drawing © Koninklijke Philips Electronics N.V. 2020 0 Sheet Subject Project All rights reserved. Reproduction in whole or in part is prohibited without prior written consent of the copyright holder. General Taiz, Yemen CathLab Room Mains power Main cabinet: · Input Ratings for the M-cabinet (L1,L2,L3,PE) 3~380V ± 10 %, 80A...125A, 50/60Hz 3~400V ± 10 %, 76A...125A, 50/60Hz 3~415V ± 10 %, 73A...125A, 50/60Hz 3~440V ± 10 %, 69A...125A, 50/60Hz 3~480V ± 10 %, 63A...125A, 50/60Hz · Hospital mains fuse: 63A-125A with gG characteristics (slow blow). · Input wiring at least: 13.3mm², max. 67.4mm². · Maximum required power: 100 kVA. · Peak currents max. 8.33ms. · All connected phase wires shall have an upstream disconnect switch with a rating of <=125A. · Mains supply impedance, requirements at mains switch: 380V , 50/60Hz, max.74mΩ 400V , 50/60Hz, max.140mΩ 415V , 50/60Hz, max.215mΩ 440V , 50/60Hz, max.325mΩ 480V , 50/60Hz, max.465mΩ If the mains resistance can't be met, an additional transformer is required. Azurion 3 F15 CardioVascular Center - Taiz Site requirements (Rel. 2.1 >) · The feasibility of this project is based on site information (like drawings) provided to Philips. Philips cannot assume any liability for the accuracy of this information and the consequences. Site requirements Equipment legend Project notes A3 mm AL-1 Sheet 3/4 © Koninklijke Philips Electronics N.V. 2020 B B Situation (scale 1:100) THIS SHEET IS PART OF THE DOCUMENT SET LISTED ON SHEET C-1 AND SHOULD NOT BE SEPARATED A3 Sheet Quote No Order No Technical ID A Taiz, Yemen CathLab Room Azurion 3 F15 CardioVascular Center - Taiz Project Schematic cross section B-B Schematic cross sections Sheet Subject Schematic cross section A-A 11-07-2023 VMI 0 4 YE-23-00003 3 (3100) (3100) 2 2900 2900 1 Drawing All rights reserved. Reproduction in whole or in part is prohibited without prior written consent of the copyright holder. 0 5m 1m A 1 : 50 mm AD-1 4/4