Architectural
Drafting and Design
Sixth Edition
Alan Jefferis
Principal of Residential Designs
Former architectural drafting instructor at Mt Hood Community College
Faculty Emeritus at Clackamas Community College
Former member of the American Institute of Building Designers.
Former Autodesk Developer Network Member
Coauthor of Residential Design Drafting and Detailing; Commercial Drafting
and Detailing; and AutoCAD® for Architecture.
David A. Madsen
President, Madsen Designs Inc.
Faculty Emeritus
Former Department Chairperson
Drafting Technology, Autodesk Premier Training Center
Clackamas Community College, Oregon City, Oregon
Former Instructor, Drafting Technology
Centennial High School, Gresham, Oregon
Autodesk Developer Network Member
Director Emeritus, American Design Drafting Association
Author of Engineering Drawing and Design, Print Reading for Engineering and
Manufacturing Technology, and Geometric Dimensioning and Tolerancing.
Coauthor of AutoCAD and its Applications, Architectural Drafting Using AutoCAD,
Civil Drafting Technology, Print Reading for Architecture and Construction Technology.
David P. Madsen
Vice President, Madsen Designs Inc.
Computer-Aided Design and Drafting Consultant and Educator
Autodesk Developer Network Member
SolidWorks Research Associate
American Design Drafting Association Member
Author of Inventor and its Applications.
Coauthor of AutoCAD and its Applications, Architectural Drafting Using AutoCAD, Civil Drafting Technology,
Engineering Drawing and Design, and Geometric Dimensioning and Tolerancing.
Australia • Brazil • Japan • Korea • Mexico • Singapore • Spain • United Kingdom • United States
This is an electronic version of the print textbook. Due to electronic rights restrictions, some third party content may
be suppressed. Editorial review has deemed that any suppressed content does not materially affect the overall
learning experience. The publisher reserves the right to remove content from this title at any time if subsequent rights
restrictions require it. For valuable information on pricing, previous editions, changes to current editions, and
alternate formats, please visit www.cengage.com/highered to search by ISBN#, author, title, or keyword for
materials in your areas of interest.
Architectural Drafting and Design,
Sixth Edition
Alan Jefferis, David A. Madsen,
and David P. Madsen
Vice President, Editorial: Dave Garza
Director of Learning Solutions: Sandy Clark
Senior Acquisitions Editor: James Devoe
© 2011, 2005, 2001, 1996, 1991, and 1986 Delmar, Cengage Learning
ALL RIGHTS RESERVED. No part of this work covered by the copyright herein
may be reproduced, transmitted, stored, or used in any form or by any means
graphic, electronic, or mechanical, including but not limited to photocopying,
recording, scanning, digitizing, taping, Web distribution, information networks,
or information storage and retrieval systems, except as permitted under
Section 107 or 108 of the 1976 United States Copyright Act, without the prior
written permission of the publisher.
Managing Editor: Larry Main
Senior Product Manager: Sharon Chambliss
Editorial Assistant: Christopher Savino
Vice President, Marketing: Jennifer Baker
Executive Marketing Manager:
Deborah S. Yarnell
For product information and technology assistance, contact us at
Professional & Career Group Customer Support, 1-800-648-7450
For permission to use material from this text or product,
submit all requests online at cengage.com/permissions
Further permissions questions can be e-mailed to
permissionrequest@cengage.com
Marketing Specialist: Mark Pierro
Production Director: Wendy Troeger
Library of Congress Control Number: 2009921885
Production Manager: Mark Bernard
ISBN-13: 978-1-4354-8162-6
Content Project Manager: David Plagenza
ISBN-10: 1-4354-8162-3
Art Director: Casey Kirchmayer
Technology Project Manager:
Christopher Catalina
Delmar
5 Maxwell Drive
Clifton Park, NY 12065-2919
USA
Cengage Learning products are represented in Canada by Nelson Education, Ltd.
For your lifelong learning solutions, visit delmar.cengage.com
Visit our corporate website at cengage.com
10% total recycled fiber
Printed in Canada
1 2 3 4 X X 12 11 10
Notice to the Reader
Publisher does not warrant or guarantee any of the products described herein
or perform any independent analysis in connection with any of the product
information contained herein. Publisher does not assume, and expressly disclaims,
any obligation to obtain and include information other than that provided to it
by the manufacturer. The reader is expressly warned to consider and adopt all
safety precautions that might be indicated by the activities described herein
and to avoid all potential hazards. By following the instructions contained herein,
the reader willingly assumes all risks in connection with such instructions. The
publisher makes no representations or warranties of any kind, including but
not limited to, the warranties of fitness for particular purpose or merchantability,
nor are any such representations implied with respect to the material set forth
herein, and the publisher takes no responsibility with respect to such material.
The publisher shall not be liable for any special, consequential, or exemplary
damages resulting, in whole or part, from the readers’ use of, or reliance upon,
this material.
Brief Contents
Preface, xiii
Acknowledgments, xix
Prologue, xxiii
SECTION 5 Supplemental
Floor Plan Drawings
SECTION 1 Introduction to
20 Plumbing Plans, 461
Architectural Design and Drafting
1 Professional Architectural Careers, Office
Practices, and Opportunities, 3
2 Introduction to Construction Procedures, 33
3 Architectural Drafting Equipment, 44
19 Electrical Plans, 431
21 Heating, Ventilating, and Air-Conditioning, 485
SECTION 6 Roof Plans
22 Roof Plan Components, 527
23 Roof Plan Layout, 547
4 Drafting Media and Reproduction Methods, 58
5 Sketching Applications, 66
SECTION 7 Elevations
6 Architectural Lines and Lettering, 87
24 Introduction to Elevations, 567
7 Computer-Aided Design and Drafting
in Architecture, 104
25 Elevation Layout and Drawing
Techniques, 589
SECTION 2 Residential Design
26 Millwork and Cabinet Technology, Cabinet
Elevations, and Layout, 608
8 Construction Specifications, 141
9 Guidelines and Required Codes That
Affect Building Design, 152
10 Room Relationships and Sizes, 177
11 Exterior Design Factors, 209
12 Conservation and Environmental Design
and Construction, 232
SECTION 3 Site Planning
13 Site Orientation, 257
14 Legal Descriptions and Site Plan Requirements, 268
15 Site Plan Layout, 285
SECTION 8 Framing Methods and Plans
27 Environmentally Friendly Framing
Methods, 631
28 Structural Components of Framed
Construction, 654
29 Design Criteria for Structural Loading, 685
30 Sizing Joists and Rafters Using Span
Tables, 694
31 Determining Beam Sizes, 708
32 Drawing Framing Plans, 727
SECTION 4 The Floor Plan
SECTION 9 Foundation Plans
16 Floor Plan Symbols, 311
33 Foundation Systems, 773
17 Floor Plan Dimensions and Notes, 360
34 Floor Systems and Foundation Support, 803
18 Floor Plan Layout, 379
35 Foundation Plan Layout, 828
iii
iv
Brief Contents
SECTION 10 Wall Sections and Details
SECTION 12 Commercial Drafting
36 Sectioning Basics, 853
42 Building Codes and Commercial Design, 953
37 Section Layout, 862
43 Common Commercial Construction Materials, 975
38 Alternative Layout Techniques, 876
44 Commercial Construction Projects, 1009
39 Stair Construction and Layout, 901
45 Structural Drafting, 1062
40 Fireplace Construction and Layout, 914
SECTION 11 Presentation Drawings
and Renderings
41 Presentation Drawings, 935
Glossary, 1095
Index, 1113
Contents
Preface, xiii
Drafting Furniture, 44
Acknowledgments, xix
Drafting Pencils and Leads, 44
Prologue, xxiii
Technical Pens and Accessories, 45
Erasers and Accessories, 45
SECTION 1 Introduction to
Architectural Design and Drafting
1
1 Professional Architectural Careers,
Office Practices, and Opportunities, 3
Drafting Instruments, 47
Drafting Machines, 50
Drafting Machine Controls and Machine Head Operation, 51
Scales, 51
Introduction, 3
Protractors, 54
Drafter, 3
Additional Resources, 56
Designer, 6
Architectural Drafting Equipment Test, 56
Interior Decorator, 6
4 Drafting Media and Reproduction Methods, 58
Kitchen and Bath Designer, 6
Interior Designer, 7
Introduction, 58
Architect, 8
Papers and Films, 58
Engineer, 9
Manual Drawing Reproduction, 59
Related Fields, 10
Design Basics, 12
Sheet Sizes, Sheet Format, Title Blocks,
and Borders, 60
Additional Resources, 31
How to Fold Prints, 61
Professional Architectural Careers, Office Practices,
and Opportunities Test, 32
Diazo Reproduction, 62
2 Introduction to Construction Procedures, 33
Introduction, 33
Photocopy Reproduction, 62
Microfilm, 62
Additional Resources, 64
Drafting Media and Reproduction Methods Test, 64
Loan Applications, 33
Individual Appraisal Requirements, 34
5 Sketching Applications, 66
Master Appraisal Requirements, 34
Introduction, 66
Change Orders, 34
Sketching Tools and Materials, 66
Building Permits, 34
Sketching Straight Lines, 66
Contracts, 35
Sketching Circular Lines, 67
Completion Notices, 35
Measurement Lines and Proportions, 68
Construction Estimates, 36
Introduction to Multiview Sketches, 71
Construction Inspections, 37
Isometric Sketches, 73
Additional Resources, 40
Introduction to Construction Procedures Test, 40
3 Architectural Drafting Equipment
44
Orthographic Projection, 75
Multiview Projection, 75
Projection of Features from an Inclined Plane, 79
Introduction, 44
Additional Resources, 84
Drafting Supplies, 44
Sketching Applications Test, 84
v
vi
Contents
National Building Codes, 155
6 Architectural Lines and Lettering, 87
Introduction, 87
Basic Design Criteria for Building Planning, 156
Types of Lines, 87
Climatic and Geographic Design Criteria, 163
Line Techniques, 91
International Energy Conservation Code, 169
Lettering, 94
Additional Resources, 174
Hints for Professional Lettering, 97
Conservation and Environmental Design and
Construction Test, 175
Additional Resources, 100
Architectural Lines and Lettering Test, 101
10 Room Relationships and Sizes, 177
7 Computer-Aided Design and
Drafting in Architecture, 104
Introduction, 177
The Floor Plan, 177
Introduction, 104
Living Area, 177
Architectural CADD Software Products, 104
Sleeping Area, 185
Productivity with CADD, 107
Service Areas, 190
The CADD Workstation, 107
Traffic Patterns, 203
Using CADD Templates, 107
Additional Resources, 207
Template Drawings on the Student CD, 108
Room Relationships and Sizes Test, 208
U.S. National CAD Standard, 108
Uniform Drawing System, 109
11 Exterior Design Factors, 209
Model and Sheet File-Naming Standards, 110
Introduction, 209
Sheet Identification, 113
Site Considerations, 209
File Management, 113
Elements of Design, 211
Sheet Organization, 113
Principles of Design, 212
Schedules, 116
Floor Plan Styles, 214
Drafting Conventions, 116
Exterior Styles, 216
CADD Graphics, 117
Additional Resources, 230
Drawing on CADD Layers, 120
Exterior Design Factors Test, 230
CADD Plotting Guidelines, 125
Additional Resources, 135
12 Conservation and Environmental
Design and Construction, 232
Computer-Aided Design and Drafting in
Architecture Test, 135
Introduction, 232
Energy-Efficient Design, 232
SECTION 2 Residential Design
8 Construction Specifications, 141
Introduction, 141
Residential Description of Materials, 141
139
The LEED Program, 233
National Association of Home Builders Model Green
Home Building, 235
Energy Star, 236
General Construction Specifications, 141
The EnviroHome Initiative, Canadian Home Builders’
Association, 236
Specifications for Residential Design, 146
Energy-Efficient Construction Practices, 237
Specifications for Commercial Construction, 146
Solar Energy Design, 237
Construction Documents, 149
Passive Solar Systems, 239
Additional Resources, 150
Envelope Design, 242
Construction Specifications Test, 150
Active Solar Systems, 242
9 Guidelines and Required Codes That
Affect Building Design
152
Geothermal Systems, 244
Wind Energy, 246
Introduction, 152
Hydroelectric Power, 246
Green Building Guidelines, 152
Biopower, 246
Contents
vii
Healthy Architectural Design and Construction, 246
SECTION 4 The Floor Plan
309
Additional Resources, 251
16 Floor Plan Symbols, 311
Conservation and Environmental Design and
Construction Test, 251
Introduction, 311
Wall Symbols, 311
SECTION 3 Site Planning
13 Site Orientation, 257
Introduction, 257
Terrain Orientation, 257
View Orientation, 257
Solar Orientation, 259
Wind Orientation, 260
Sound Orientation, 264
Additional Resources, 266
Site Orientation Test, 267
255
Wall Shading and Material Indications, 316
Door Symbol Representations, 318
Window Symbol Representations, 321
Schedules, 324
Cabinets, Fixtures, and Appliances on Floor Plans, 332
Common Sizes of Architectural Features, 337
Floor Plan Materials, 339
Stair Planning and Floor Plan Representation, 341
Hallways on Floor Plans, 345
Fireplaces on Floor Plans, 346
Solid Fuel–Burning Appliances, 350
14 Legal Descriptions and Site
Plan Requirements, 268
Room Titles on Floor Plans, 351
Other Floor Plan Symbols, 351
Introduction, 268
Conclusion, 354
Metes and Bounds System, 268
Additional Resources, 357
Rectangular Survey System, 268
Floor Plan Symbols Test, 358
Lot and Block System, 271
Site Plan Requirements, 272
17 Floor Plan Dimensions and Notes, 360
Topography, 272
Introduction, 360
Drawing Site Plans, 274
Aligned Dimensions, 360
Grading Plan Features, 275
Floor Plan Dimensions, 360
Site Analysis Plan, 277
Placing Exterior Dimensions, 360
Subdivision Plans, 280
Placing Interior Dimensions, 364
Planned Unit Development, 281
Standard Feature Dimensions, 364
Metrics in Site Planning, 281
Omitting Dimensions Established by the Foundation, 365
Additional Resources, 284
Dimensioning Arc and Circular Floor Plan Features, 366
Legal Descriptions and Site Plan
Requirements Test, 284
Common Sizes of Architectural Features, 367
15 Site Plan Layout, 285
Introduction, 285
Site Design Considerations, 286
Rural Residential Fire Department Access and Site
Planning, 287
Laying Out Property Lines, 288
Steps in Site Plan Layout, 289
Site Plan Drawing Checklist, 290
Masonry Veneer on the Floor Plan, 369
Concrete-Block and Structural Masonry Construction
on the Floor Plan, 369
Solid Concrete Construction on the Floor Plan, 370
Floor Plan Notes and Specifications, 370
Designing Floor Plans Using Standard Construction
Modules, 372
Using Metric Dimensions, 372
Additional Resources, 377
Floor Plan Dimensions and Notes Test, 377
Drawing Contour Lines, 291
Drawing Profiles, 293
18 Floor Plan Layout, 379
Drawing Grading Plans, 294
Introduction, 379
Additional Resources, 303
Steps for Laying Out a Floor Plan, 379
Site Plan Layout Test, 303
Second-Floor Plan Layout, 392
viii
Contents
Basement Plan Layout, 394
Plumbing Plan Drawing Checklist, 478
Floor Plan Drawing Checklist, 398
Additional Resources,, 483
Additional Resources, 403
Plumbing Plans Test, 483
Floor Plan Layout Test, 403
21 Heating, Ventilating, and Air-Conditioning, 485
Introduction, 485
SECTION 5 Supplemental Floor
Plan Drawings
429
Central Forced-Air Systems, 485
Forced-Air Heating Plans, 486
19 Electrical Plans, 431
Hot Water Systems, 490
Introduction, 431
Heat Pump Systems, 490
Electrical Terms and Definitions, 431
Zone Control Systems, 491
Electrical Circuit Design, 432
Radiant Heat, 492
Basic Electrical Design Recommendations, 433
Thermostats, 492
Home Automation, 434
Heat Recovery and Ventilation, 493
Electrical Design Considerations, 435
Exhaust Systems: Code Requirements, 495
Smoke Detectors, 437
Central Vacuum Systems, 495
Carbon Monoxide Alarms, 437
HVAC Symbols, 495
Universal Electrical Installations, 437
Universal HVAC Design, 497
Electrical Symbols, 439
HVAC Code Requirements, 498
Light Fixture Design and Placement, 443
Thermal Calculations for Heating/Cooling, 499
Reflected Ceiling Plans, 446
Steps in Filling Out the Residential Heating Data Sheet, 500
Electrical Schedules, 446
Steps in Filling Out the Residential Cooling Data Sheet, 506
Electrical Wiring Specifications, 447
HVAC Drawings, 511
Metrics in Electrical Installations, 448
HVAC Plan Drawing Checklist, 516
Steps in Drawing the Electrical Plan, 448
Additional Resources, 520
Drawing the Upper-Floor Electrical Plan, 449
Heating, Ventilating, and Air-Conditioning Test, 520
Electrical Plan Drawing Checklist, 449
Additional Resources, 458
Electrical Plans Test, 459
SECTION 6 Roof Plans
22 Roof Plan Components, 527
20 Plumbing Plans, 461
Introduction, 527
Introduction, 461
Types of Roof Plans, 527
Plumbing Terms and Definitions, 462
Common Roof Terms, 527
Sizing of Plumbing Piping, 464
Roof Shapes, 533
Universal Plumbing Installations, 464
Roofing Materials, 539
Plumbing Schedules, 466
Roof Ventilation and Access, 543
Plumbing Drawings, 466
Additional Resources, 545
Water Systems, 466
Roof Plan Components Test, 545
Drainage and Vent Systems, 469
Isometric Plumbing Drawings, 470
23 Roof Plan Layout, 547
Automatic Fire Sprinkler Systems, 471
Introduction, 547
Sewage Disposal, 472
Representing Roof Plan Components, 547
Fire Sprinkler Systems, 474
Representing Structural Materials, 553
Metrics in Plumbing, 474
Representing Nonstructural Material, 554
Adding Plumbing Information to the Floor Plan, 475
Dimensions, 557
Commercial Plumbing Drawings, 475
Annotation, 557
525
Contents
ix
Drawing Gable Roof Plans, 558
28 Structural Components of Framed
Construction, 654
Drawing Hip Roof Plans, 559
Drawing Dutch Hip Roof Plans, 560
Introduction, 654
Roof Plan Checklist, 563
Floor Construction, 654
Roof Plan Layout Test, 563
Framed Wall Construction, 664
Roof Construction, 672
SECTION 7 Elevations
565
Additional Resources, 683
Structural Components Test, 684
24 Introduction to Elevations, 567
29 Design Criteria for Structural Loading, 685
Introduction, 567
Major Considerations of Drawing Elevations, 567
Introduction, 685
Representing Materials in Elevation, 572
Types of Loads, 685
Additional Resources, 587
Load Design, 688
Introduction to Elevations Test, 588
Load Distribution, 690
Design Criteria for Structural Loading Test, 692
25 Elevation Layout and Drawing Techniques, 589
30 Sizing Joists and Rafters Using Span Tables, 694
Introduction, 589
Layout, 589
Introduction, 694
Drawing Finished-Quality Lines Manually, 593
Determining Wood Characteristics, 694
Annotation, 595
Determining Size and Span, 694
Drawing Roof Intersections, 596
Working with Engineered Lumber, 699
Drawing Irregular Shapes, 597
Additional Resources, 706
Projecting Grades, 600
Sizing Joists and Rafters Using Span Tables Test, 706
Elevation Checklist, 606
31 Determining Beam Sizes, 708
Elevation Layout and Drawing Techniques Test, 607
Introduction, 708
Structural Lumber, 708
26 Millwork and Cabinet Technology,
Cabinet Elevations, and Layout, 608
Loading Reactions of Wood Members, 710
Introduction, 608
Methods of Beam Design, 712
Types of Millwork, 608
Sizing Wood Beams Using Standard Formulas, 714
Cabinets, 612
Wood Adjustment Factors, 718
Cabinet Elevations and Layout, 617
Review, 719
Bathroom Cabinet Layout, 623
Sizing Beams Using Span Tables, 720
Cabinet Elevations Checklist, 623
Sizing Laminated Beams, 720
Additional Resources, 627
Working with Engineered Beams, 720
Millwork and Cabinet Technology, Cabinet Elevations,
and Layout Test, 627
Simple Beam with a Load Concentrated at the Center, 721
Simple Beam with a Load Concentrated at Any Point, 723
Cantilevered Beams with a Uniform Load, 723
SECTION 8 Framing Methods and Plans
629
27 Environmentally Friendly Framing Methods, 631
Introduction, 631
Additional Resources, 725
Determining Beam Sizes Test, 725
32 Drawing Framing Plans, 727
Wood Framing Methods, 631
Introduction, 727
Energy-Efficient Framing Methods, 638
Major Components Represented on a Framing Plan, 727
Green Construction Goals, 649
Additional Resources, 652
Resisting Lateral Loads Using the Prescriptive Path of
the Code, 735
Framing Methods Test, 653
Completing a Framing Plan, 751
x
Contents
Roof Framing Plans, 753
Types of Sections, 853
Roof Framing Plan Checklist, 759
Drawing Scale, 856
Floor Framing Plans, 759
Representing and Locating Materials, 858
Roof Framing Plan Checklist, 762
Sectioning Basics Test, 861
Framing Plan Checklist, 764
37 Section Layout, 862
Additional Resources, 770
Introduction, 862
Drawing Framing Plans Test, 770
Stage 1: Evaluate Needs, 862
SECTION 9 Foundation Plans
771
33 Foundation Systems, 773
Stage 2: Lay Out the Section, 862
Stage 3: Finished-Quality Lines for Structural
Members Only, 864
Stage 4: Drawing Finishing Materials, 867
Introduction, 773
Stage 5: Dimensioning, 869
Soil Considerations, 773
Stage 6: Lettering Notes, 870
Types of Foundations, 777
Stage 7: Evaluating Your Work, 871
Dimensioning Foundation Components, 798
Section—Trusses Checklist, 871
Additional Resources, 800
Section Layout Test, 874
Foundation Systems Test, 801
38 Alternative Layout Techniques, 876
34 Floor Systems and Foundation Support, 803
Introduction, 876
Introduction, 803
Floor Joist/Foundation, 876
On-Grade Foundations, 803
Post-and-Beam Foundations, 879
Crawl Space Floor Systems, 814
Basement with Concrete Slab, 881
Additional Resources, 826
Conventional (Stick) Roof Framing, 886
Floor Systems and Foundation Support Test, 827
Section—Rafters Checklist, 892
Garage/Residence—Section, 892
35 Foundation Plan Layout, 828
Alternative Layout Techniques Test, 895
Introduction, 828
Concrete Slab Foundation Layout, 828
39 Stair Construction and Layout, 901
Slab Foundation Plan Checklist, 831
Introduction, 901
Foundation Plan with Joist Construction, 831
Stair Terminology, 901
Foundation Plan with Joists Checklist, 835
Determining Rise and Run, 902
Standard Foundation with Post-and-Beam Floor
System, 835
Straight Stair Layout, 903
Foundation Plan with Post-and-Beam Checklist, 840
Open Stairway Layout, 906
Combination Slab and Crawl Space Plans for a Partial
Basement, 840
U-Shaped Stairs, 909
Checklist for Foundation Plans with Partial Slab and
Floor Joists, 844
Exterior Stairs, 910
Full Basement, 844
Additional Resources, 913
Foundation Plan Layout Test, 849
Stair Construction and Layout Test, 913
SECTION 10 Wall Sections and Details
36 Sectioning Basics, 853
L-Shaped Stairs, 910
Section—Stair Checklist, 911
851
40 Fireplace Construction and Layout, 914
Introduction, 914
Fireplace Alternatives, 914
Introduction, 853
Fireplace Terms, 915
Section Origination, 853
Drawing the Fireplace Section, 921
Section Alignment, 853
Section—Masonry Fireplace Checklist, 926
Contents
xi
Fireplace Elevations, 928
45 Structural Drafting, 1062
Additional Resources, 931
Introduction, 1062
Fireplace Construction and Layout Test, 931
Plan the Drawing, 1062
Procedure—From Calculations to Working
Drawing, 1062
SECTION 11 Presentation Drawings
and Renderings
933
Order of Precedence, 1065
Structural Drafting Project, 1066
41 Presentation Drawings, 935
Introduction, 935
BOXED FEATURES
Types of Presentation Drawings, 935
Methods of Presentation, 936
Going Green
Rendering Procedure for Drawings, 941
An Introduction to Green Design, 12
Presentation Drawings Test, 948
Sustainable Design Opportunity, 130
GreenFormat, 148
SECTION 12 Commercial Drafting
951
Green Codes, 173
Green Design Considerations, 207
42 Building Codes and Commercial Design, 953
Green Styles, 228
Introduction, 953
An Overview, 233
Exploring Building Codes, 953
The Ultimate Urban Green Home, 248
Determining Design Categories, 955
Environmentally Sound Landscaping Practices, 265
Using the Codes, 971
Designing an Ecosystem, 301
Additional Resources, 973
Windows and Energy Loss, 325
Building Codes and Commercial Design Test, 974
The International Energy Conservation Code, 396
Living Smart, 400
43 Common Commercial Construction
Materials, 975
Introduction, 975
Wood, 975
Concrete Block, 979
Poured Concrete, 983
Steel Construction, 988
Common Connection Methods, 995
Additional Resources, 1005
Common Commercial Construction Materials Test, 1007
44 Commercial Construction Projects, 1009
Introduction, 1009
Office Practice, 1009
Drawing Organization, 1011
Site Drawings, 1013
Architectural Drawings, 1017
Going Green, 404
Energy Conservation, 434
Electricity Generation from Wind Power, 456
Energy Conservation, 465
Solar Hot Water, 473
Indoor Water Use, 481
Improving Indoor Air Quality, 509
Green Roofing, 544
Green Applications of Exterior Elevations, 587
Green Framing, 637
Environmentally Friendly Design and
Construction, 682
Green Foundations, 800
Green Floor Systems, 826
Goals of an Energy-Efficient Fireplace, 922
Green Design Considerations, 1003
Structural Drawings, 1038
CADD Applications
Electrical Drawings, 1050
CADD Applications, 56
Fixture Drawings, 1052
Drafting Archives, 60
Mechanical Drawings, 1054
Plumbing Drawings, 1055
Using CADD for Conceptual Design
and Presentation Sketches, 80
Commercial Construction Projects Test, 1061
Drawing Lines, 92
xii
Contents
CADD Lettering, 97
CADD Applications, 392
The Future Is Here with CADD, 106
CADD Applications, 392
Architectural CADD Symbols, 119
CADD Applications, 394
This Is What the Future Looks Like: Web-Based
Architectural Collaboration, 129
Using CADD to Draw Floor Plans, 399
Using Surveyor’s Units, 289
Drawing Electrical Symbols with CADD, 454
Using CADD to Draw Site Plans, 296
Drawing Plumbing Symbols with CADD, 479
CADD Applications, 311
CADD in the HVAC Industry, 517
CADD Applications, 316
Drawing Roof Plans with CADD, 561
Drawing Floor Plan Walls Using CADD, 317
CADD Elevations and Symbols, 586
U.S. National CAD Standard for Schedules, 330
CADD Applications, 589
Placing Material Symbols with CADD, 340
CADD Applications, 600
Designing and Drawing Stairs with CADD, 345
Options for Creating Cabinet Elevations, 621
CADD Floor Plan Symbols, 354
Drawing Millwork and Cabinet Elevations with CADD, 625
Placing Architectural Dimensions with CADD, 374
Drawing Framing Plans with CADD, 769
CADD Applications, 381
Using CADD to Draw Foundation Plans, 847
CADD Applications, 383
Drawing Sections and Details with CADD, 872
CADD Applications, 384
Drawing Stairs with CADD, 912
CADD Applications, 385
CADD Applications, 385
Drawing Fireplace Sections and Elevations
with CADD, 930
CADD Applications, 386
Using CADD to Make Presentation Drawings, 948
CADD Applications, 387
The Code and Computers, 973
CADD Applications, 387
Commercial Drawings, 1058
CADD Applications, 431
CADD Applications, 388
CADD Applications, 389
CADD Applications, 390
Glossary, 1095
CADD Applications, 390
Index, 1113
Preface
For nearly 25 years, students have relied on Architectural
Drafting and Design for easy-to-read, comprehensive coverage of architectural drafting and design instruction that
complies with and reinforces architectural, engineering,
and construction industry standards and practices.
This sixth edition of Architectural Drafting and Design
is a practical, comprehensive textbook that is easy to use
and understand. The content can be used as presented
by following a logical sequence of learning activities for
residential and light commercial architectural drafting
and design, or the chapters can be rearranged to accommodate alternate formats for traditional or individualized instruction.
AMERICAN DESIGN
DRAFTING ASSOCIATION
(ADDA) APPROVED
PUBLICATION
The content of this text is considered a fundamental
component to the design-drafting profession by the
American Design Drafting Association. This publication
covers topics and related material, as stated in the ADDA
Curriculum Certification Standards and the ADDA
Certified Drafter Examination Review Guide. Although
this publication is not conclusive, with respect to ADDA
standards, it should be considered a key reference tool
in pursuit of a professional design-drafting career.
ABOUT THE
INTERNATIONAL CODE
COUNCIL
The International Code Council (ICC)
is a nonprofit membership association
dedicated to protecting the health,
safety, and welfare of people by creating better buildings and safer communities. The mission of ICC is to
provide the highest quality codes, standards, products,
and services for all concerned with the safety and performance of the building environment. ICC is the publisher
of the family of the International Codes® (I-Codes®), a
single set of comprehensive and coordinated model
codes. This unified approach to building codes enhances
safety, efficiency, and affordability in the construction of
buildings. The Code Council is also dedicated to innovation, sustainability, and energy efficiency. Code Council
subsidiary, ICC Evaluation Service, issues Evaluation
Reports for innovative products and reports of Sustainable Attributes Verification and Evaluation (SAVE).
Headquarters: 500 New Jersey Avenue, NW,
6th Floor, Washington, DC 20001-2070
District Offices: Birmingham, AL; Chicago. IL;
Los Angeles, CA
1-888-422-7233
www.iccsafe.org
APPROACH
Architectural Drafting and Design provides a practical
and realistic approach to solving problems that are
encountered in the architectural design world.
Practical
Architectural Drafting and Design provides a practical
approach to architectural drafting as it relates to current
standard practices. The emphasis on standardization is
an excellent and necessary foundation of drafting training as well as for implementing a common approach
to drafting nationwide. After students become professional drafters, this text will serve as a valuable desk
reference.
Realistic
Chapters contain professional examples, illustrations,
step-by-step layout techniques, drafting problems, and
related tests. The examples demonstrate recommended
drafting presentation with actual architectural drawings
used for reinforcement. The correlated text explains
drafting practices and provides useful information for
knowledge building and skill development. Step-by-step
layout methods provide a logical approach to beginning
and finishing complete sets of working drawings.
xiii
xiv
Practical Approach to Problem Solving
The professional architectural drafter’s responsibility is to
convert architects’, engineers’, and designers’ sketches and
ideas into formal drawings. This textbook explains how
to prepare formal drawings from design sketches by
providing the learner with basic guidelines for drafting
layout and minimum design and code requirements in
a knowledge-building format. One concept is learned
before the next is introduced. The concepts and skills
learned from one chapter to the next allow students to
prepare complete sets of working drawings for residential and light commercial construction projects. Problem
assignments are presented in order of difficulty and in
a manner that provides students with a wide variety of
architectural drafting experiences.
Real-World Architectural Problems
The problems are presented as preliminary designs or
design sketches in a manner that is consistent with
actual architectural office practices. It is not enough for
students to duplicate drawings from given assignments;
they must be able to think through the process of drawing development with a foundation based on how drawing and construction components are put into practice.
The goals and objectives of each problem assignment
are consistent with recommended evaluation criteria
based on the progression of learning activities. The drafting problems and tests recommend that work be done
using drafting skills on actual drafting materials with
either professional manual or computer-aided drafting
equipment. A problem solution or test answer should be
accurate and demonstrate proper drafting practice.
FEATURES OF THE TEXTBOOK
Major features of this textbook that guide you through
the world of architectural design and drafting include
realistic application of the information presented
throughout each chapter, professional illustrations of
each concept to be explored, CADD applications of each
type of working drawing, exploration of the 2009 building codes and standards produced by the International
Code Council, the National Association of Home Builders
(NAHB), and Leadership in Energy and Environmental
Design (LEED).
Applications
Special emphasis has been placed on providing realistic
drafting problems. Problems are presented as design
sketches or preliminary drawings in a manner that is consistent with architectural practices. The problems have
Preface
been supplied by architects and architectural designers.
Each problem solution is based on the step-by-step layout
procedures provided in the chapter discussions.
Problems are given in order of complexity to expose
students to a variety of drafting experiences. Problems
require students to go through the same thought and
decision-making processes that a professional drafter
faces daily, including scale and paper size selection,
view layout, dimension placement, section placement,
and many other activities. Problems can be solved using
manual or computer-aided drafting, as determined by
individual course guidelines. Chapter tests provide
complete coverage of each chapter and can be used for
student evaluation or as review.
Illustrations
Drawings and photos are used liberally throughout this
textbook to strengthen the concepts presented. Fullcolor treatment enhances the clarity. Abundant stepby-step illustrations take students through the detailed
stages of the drafting process for each application. The
step-by-step illustrations are created using computeraided drafting for the highest accuracy and quality.
Computer-Aided Design and Drafting
(CADD)
CADD is presented as a valuable tool that has revolutionized the architectural design and drafting industry.
The complete discussion of CADD introduces the
workstation environment, terminology, drafting techniques, and sample drawings. Although individual
course guidelines may elect to solve architectural drafting problems using either computer-aided or manual
drafting equipment, the concepts remain the same, with
the only difference being the method of presentation.
Construction Techniques
and Building Codes
Construction techniques differ throughout the country.
This text clearly acknowledges the difference in construction methods and introduces the student to the
format used to make a complete set of working drawings for each method of construction. Students may learn
to prepare drawings from each construction method
or, more commonly, for the specific construction
techniques that are used in their locality. The problem
assignments are designed to provide drawings that
involve a variety of construction alternatives.
To provide oversight of the wide range of construction methods and materials used throughout the country,
Preface
the 2009 model codes written by the International
Code Council (ICC) are referenced throughout this
textbook. The major ICC codes addressed in this
textbook include the International Residential Code
(IRC) in Chapter 1 through Chapter 41 and the International Building Code (IBC) in Chapter 42 through
Chapter 45. Although many municipalities have adopted
their own versions of these codes, the use of these
model codes provides a firm background before exploring local variations.
Additional Resources
At the end of most chapters, an Additional Resources
section provides students with information on
additional resources related to chapter topics. This
section lists Web sites for companies or organizations that offer materials, services, and standards
related to the chapter content. The following is an
example of how the Additional Resources are presented in the textbook:
Chapter Tests
Chapter tests are found at the end of each chapter.
Select the Chapter Tests link on the Student CD to access
chapter tests using Microsoft Word. The chapter tests
allow you to review or test your knowledge of the related
chapter content, depending on your course objectives.
Open the related link and answer the questions electronically, unless otherwise directed by your instructor.
xv
NEW TO THE SIXTH EDITION
Architectural Drafting and Design, Sixth Edition, provides
the following improvements over the fifth edition.
Codes and Standards Compliance
Each chapter is based on information provided by the
following major industry leaders:
●
2009 editions of the International Residential Code
and the International Building Code published by the
International Code Council.
● National CAD Standards Version 4.
● MasterFormat and UniFormat published by The
Construction Specifications Institute (CSI) and
Construction Specifications Canada (CSC).
● LEED rating system published by the U.S. Green
Building Council (USGBC).
● Model Green Home Building Guidelines (MGHBG)
developed by the National Association of Home
Builders (NAHB) and the International Code Council
(ICC), which publishes the International Residential
Code (IRC).
Going Green
Protecting the environment is one of the most important
worldwide issues today. A new flagship feature called
Going Green is found throughout this textbook, providing current, practical, and experimental energy-efficient
xvi
architectural design and construction techniques that
result in a significant reduction in energy consumption.
As the building industry grows to meet the demands
of our increasing population, we must take care of
the environment and allow for current and future
development.
As a student, it is very important for you to learn what
is available today and to find ways to improve energy
efficiency in architectural design and construction into
the future in an effort to protect the earth. National and
local programs have been established to meet this need. A
leading program is often referred to as green building. The
U.S. Green Building Council (USGBC) is a key organization developed to promote building design and construction that is environmentally responsible and healthy,
while allowing construction to remain profitable. Modern
advances in building construction are available to designers, builders, and owners who want to “build green” and
make the most of environmental protection in the architectural and construction industries. The following is part
of one of the Going Green features found in this edition:
Preface
by a CD icon in appropriate locations throughout this
textbook. The supplemental reference material provides optional learning opportunities. The supplemental
material ranges from commonly known topics available
for students desiring a review, to advanced information
that is beyond the scope of this textbook for students
interested in further exploration. The supplemental
chapter readings are identified within chapter content
in this manner:
CADD Applications
CADD Applications is a special boxed feature that provides a variety of real-world examples, professional
presentations, software applications, tips, standards,
and procedures used with computer-aided design and
drafting. CADD Applications were first introduced in
the fourth edition but have been revised, improved, and
expanded due to the rapidly changing CADD industry. CADD Applications in the sixth edition range from
one-sentence statements to multipage content. The
following is an example of part of one of the CADD
Applications found in the sixth edition:
Note
Supplemental Chapter Readings
Students are directed to supplemental chapter readings
that are found on the Student CD and are identified
The Note feature is provided throughout this textbook
to provide brief information related to the specific
content where the note is found. The following is an
example of a sixth edition note:
Preface
NOTE: Although both groups have produced “guidelines,”
many municipalities are starting to move beyond the
recommendation stage and are incorporating portions
of these guidelines into their design and building requirements. It is expected that with the 2012 edition of the ICC
codes, the NGBS-ICC 700 will move from guidelines to law.
Verify with the municipality that will govern each specific
building project to determine if specific aspects of a green
guideline are required. The ICC is also planning to develop
a green building code for buildings that are not covered
by the NGBS-ICC 700. This code will most likely be the
International Green Construction Code (IGCC).
THE STUDENT CD
Although not new to the sixth edition, the Student CD
has new and improved content.
A student CD icon found throughout this textbook
guides students to features found on the CD. Refer to
the Prologue for a complete description of each component and how to use the Student CD.
The following features are found on the Student CD:
●
Supplemental Chapter Readings
● Step-by-Step Layout Drawings
● Chapter Tests
● Drawing Checklists
● Drawing Problems
● Drawing Templates
● Architectural Blocks and Symbols
● Related Web Links
● Workbook
● Video Clips of Major Concepts
● Review Questions
ORGANIZING YOUR COURSE
Architectural drafting is the primary emphasis of many
technical drafting curricula; however, many other programs offer only an exploratory course in this field. This
textbook is appropriate for either application, as its content reflects the common elements in any architectural
drafting curriculum.
Prerequisites
An interest in architectural drafting, plus basic arithmetic, written communication, and reading skills are
xvii
the only prerequisites required. Basic drafting skills
and layout techniques are presented as appropriate.
Students with an interest in architectural drafting who
begin using this text will end with the knowledge and
skills required to prepare complete sets of working
drawings for residential and light commercial architectural construction projects.
Fundamental through Advanced
Coverage
This textbook can be used in an architectural drafting
curriculum that covers the basics of residential architecture in a one-, two-, or three-semester sequence. In this
application, students use the chapters directly associated with the preparation of a complete set of working
drawings for a residence, where the emphasis is on the
use of fundamental skills and techniques. The rest of the
textbook can remain as a reference for future study or as
a valuable desk reference.
This textbook can also be used in the comprehensive architectural drafting program where a four- to
six-semester sequence of residential and light commercial architectural drafting and design is required.
In this application, students can expand on the primary objective of preparing a complete set of working
drawings for the design of residential and light commercial projects with the coverage of any one or all
of the following areas: energy-efficient construction
techniques, solar and site orientation design applications, heating and cooling thermal performance calculations, structural load calculations, and presentation
drawings.
Section Length
Chapters are presented in individual learning segments
that begin with elementary concepts and build until
each chapter provides complete coverage of every topic.
Instructors can choose to present lectures in short,
15-minute discussions or divide each chapter into 40- to
50-minute lectures.
Drafting Equipment and Materials
Identification and use of manual and computer-aided
drafting equipment is outlined. Students need an inventory of equipment available for use as listed in the
chapters. Professional drafting materials are explained,
and it is recommended that students prepare problem
solutions using actual drafting materials.
xviii
SUPPLEMENTS
Instructor Resources
Spend Less Time Planning and More Time
Teaching
With Delmar, Cengage Learning’s Instructor Resources
to accompany Architectural Drafting and Design, 6th
Edition, preparing for class and evaluating students has
never been easier!
This invaluable instructor CD-ROM, titled e.resource,
allows you anywhere, anytime access to all of your
resources. (ISBN: 1–4354–8163–1)
Features contained in e.resource include:
●
●
●
Syllabus: Lesson plans created by chapter. You have
the option of using these lesson plans with your own
course information. (http://www.worldclasslearning
.com)
Chapter Hints: Objectives and teaching hints that
provide the basis for a lecture outline that helps you
to present concepts and material. Key points and
concepts can be graphically highlighted for student
retention.
PowerPoint Presentation: Slides for each chapter of
the text provide the basis for a lecture outline that
helps you to present concepts and material. Key
points and concepts can be graphically highlighted
for student retention.
Preface
●
Exam View Computerized Test Bank: More than 800
questions of varying levels of difficulty are provided
in true/false and multiple-choice formats so you can
assess student comprehension.
● Video and Animation Resources: These AVI files graphically depict the execution of key concepts and commands in drafting, design, and AutoCAD and let you
bring multimedia presentations into the classroom.
Solutions Manual
A solutions manual is available with answers to endof-chapter review questions and solutions to end-ofchapter problems. Solutions are also provided for the
Workbook problems. (ISBN: 1–4354–8165–8)
Videos
Two video sets, containing four 20-minute tapes each,
are available. The videos correspond to the topics
addressed in the text:
●
Set #1: ISBN 0–7668–3094–2
● Set #2: ISBN 0–7668–3095–0
Video sets are also available on interactive video
CD-ROM.
●
Set #1: ISBN 0–7668–3116–7
● Set #2: ISBN 0–7668–3117–5
Acknowledgments
Preface
The authors would like to thank and acknowledge the
many professionals who reviewed the sixth edition of
Architectural Drafting and Design. A special acknowledgment is due the instructors who reviewed the chapters
in detail.
Sharon Bagby
Texas State Technical College, Sweetwater, Texas
2009 International Residential Code and the International
Building Code.
Portions of this publication reproduce text from the
2009 International Residential Code, Copyright 2009,
with the permission of the publisher, the International
Conference of Building Officials, under license from the
International Code Council Inc., Falls Church, Virginia.
The 2009 International Residential Code is a copyrighted
work of the International Code Council. Reproduced
with permission. All rights reserved.
Amanda Boyle
Texas State Technical College, Marshall, Texas
Alan Mascord Design Associates, Inc.
(www.mascord.com)
Rebecca R. Brining
Virginia College, Mobile, Alabama
For more than 20 years, a deep-rooted commitment
to architectural excellence has made Alan Mascord a
trusted name among builders, consumers, and competitors. To date, well over 50,000 Mascord homes have
been built across the United States, Canada, and in most
developed countries around the world.
Alan Mascord Design Associates provides more than
600 stock home plans in a wide range of architectural
styles, from single-family homes to multifamily dwellings, including detached garage plans. An active custom
design business serves clients with specific and unique
requirements, and Efficient Living Services provides
builders with tools and resources for building green.
Mascord Efficient Living (ISBN-10 0–9788–1131–3) is a
guide to the philosophies and practicalities of green building for builders and consumers. Presenting more than 50
home plans detailed to meet nationally recognized green
building standards, this book explains the elements to
consider before, during, and after construction.
Special thanks are given to Jon Epley and Gary
Higginbotham for their professional support for this
edition in providing content, photographs, and illustrations for several Going Green features found throughout
this textbook. Mascord Design Associates also provided
several sets of working drawings used for problems in
Chapter 18.
Reviewers
Clark Cory
Purdue University, West Lafayette, Indiana
Tom Felton
Western Technical College, La Crosse, Wisconsin
Andy Jacobs
West-Oak High School, Westminster, South Carolina
David K. Landry
Louisiana Technical College, Lafayette, Louisiana
Edward J. Rother
Cerritos College, Norwalk, California
Contributing Companies
The quality of this textbook is also improved by the support and contributions from architects, designers, engineers, and vendors. The list of contributors is extensive
and acknowledgment is given at each illustration. The
following individuals and companies gave an extraordinary amount of support with technical information and
art for this edition.
International Code Council (ICC)
Special thanks goes to Hamid Naderi, Vice President of
Product Development of the International Code Council
(ICC), for reviewing the content of this text related to
the ICC codes and for allowing us to use text from the
3D.DZYN
Special thanks to Ron Palma, 3D.DZYN, for providing loyal feedback related to professional architectural
xix
xx
Acknowledgments
CADD applications. Palma has more than 20 years of
experience in the architectural industry as a drafter,
designer, lead project designer, and, most recently, as
a CAD manager implementing Architectural Desktop
for a residential design firm. He is an Autodesk
Certified Instructor, trainer, and support technician for
an Autodesk reseller. Palma has professional experience
as an educator at two community colleges and is a U.S.
Army certified instructor. In addition, He taught the
Instructor Trainer’s Course for the U.S. Army and has
taught courses at Autodesk University. Palma is the coauthor of architectural drafting and AutoCAD books.
Res Communis (www.rescommunis.org)
A design collective started by Garrett and Dustin Moon,
Res Communis is dedicated to the creation and dissemination of “good” design for all, not just for those who can
afford it. Their goal is to contribute to the solving of problems, not the concentration and collection of intellectual
property. To that end, every idea and design created is
released to the public to use and refine for the good of
all. Garrett and Dustin Moon provided the content and
illustrations for the Going Green content in Chapter 12.
The Going Green feature titled The Ultimate Urban Green
Home is the flagship of the Going Green features found in
this textbook, demonstrating perfect, sustainable, and selfsufficient design using super-energy-efficient, environmentally safe materials, and clean energy technologies.
Construction Specifications Institute
(www.csinet.org)
Information used in this text is from MasterFormat
and UniFormat and is published by The Construction
Specifications Institute (CSI) and Construction
Specifications Canada (CSC), and is used with permission from CSI, 2008.
The Construction Specifications Institute (CSI)
99 Canal Center Plaza, Suite 300
Alexandria, VA 22314
800-689-2900; 703-684-0300
Bryan Higgins
Architect Bryan Higgins, AIA, LEED AP, from Portland,
Oregon, provided a set of working drawings and
photographs of his design of one of the winning homes
in the Living Smart program, in Portland, Oregon. The
Living Smart program design competition created a
catalog of affordable home plans designed for narrow
lots, called small-footprint houses. His Living Smart
small-footprint design is used in Problem 18–1. Higgins
also provided the content for the Going Green feature in
Chapter 18 of this textbook.
Leann Collins and Laura Numbers
Leann Collins and Laura Numbers contributed a complete set of working drawings and related photographs
for a small-footprint residential architectural design.
This small footprint is one of the winning homes in the
Living Smart program, in Portland, Oregon, and the
design is used in Problem 18–3.
TKP Architects, PC, Golden, Colorado
(www.keating-partnership.com)
Thanks to Erin Elston with TKP Architects for the contribution of residential architectural plans and impressive photographs.
DeSantis Landscapes
Dean DeSantis, CLP, President of DeSantis Landscapes,
provided the content and photographs used in a Going
Green feature found in Chapter 12.
Southwest Windpower
(www.windenergy.com)
Michael French, Graphics Coordinator for Southwest
Windpower, provided the content, photographs, and
illustrations for the Going Green feature in Chapter 19.
Autodesk, Inc. (www.autodesk.com)
Catherine Palmer, Marketing Manager, AEC Initiatives
provided the Going Green feature content in Chapter 7.
As a world leader in design innovation technologies,
Autodesk helps to empower architecture, engineering,
and construction professionals with cost-effective designs
and delivers high-performing, resource-efficient buildings and infrastructure.
Solatube International, Inc.
(www.solatube.com)
Bridget Palitz, Vice President of The McRae Agency,
Public Relations for Solatube International, Inc., provided the content, photographs, and illustrations for a
Going Green feature in Chapter 16.
National Fenestration Rating Council (NFRC)
(www.nfrc.org)
The NFRC provided content and illustrations for a
Going Green feature in Chapter 16.
Engineering Drawing and Design
Approximately 180 illustrations are reproduced from
Engineering Drawing and Design, by David A. Madsen,
David P. Madsen, and J. Lee Turpin from Delmar
Publishers.
Acknowledgments
Step-by-Step Model Home Plan Drawings
The authors greatly appreciate the efforts of David P.
Madsen, Tereasa Jefferis, and Connie Wilmon for their
work with the step-by-step drawings found in layout
chapters. In addition, we would like to thank:
Janice Jefferis for her photo contributions
Ken Smith, Kenneth D. Smith Architects and
Associates, Inc.
Richard Wallace, Southern Forest Products
Association
APA—The Engineered Wood Association
Richard Branham, National Concrete Masonry
Association
Pamela Allsebrook, California Redwood Association
Eric Brown, Eric S. Brown Design Group, Inc.
Kathleen M. Arnelt, Louisiana-Pacific Corporation
Richard R. Chapman and Robert C. Guzikowski,
Simpson Strong-Tie Company, Inc.
Stephen Fuller, Incorporated
Steven Merrill, Mechanical Designer
Havlin Kemp, VLMK Consulting Engineers
Western Wood Products Association
Rajni Pisharody and the staff at Glyph Internaional
for their excellent work on the production of this text.
Julie Searls for her excellent mastery of the English
language and skill as a copy editor.
To the Student
Architectural Drafting and Design is designed for you, the
student. The development and format of the presentation have been tested in conventional and individualized classroom instruction. The information presented
is based on the National CAD Standards, drafting room
practice, and trends in the architectural design industry.
This textbook is the only architectural drafting reference that you need. Use the textbook as a learning tool
while in school, and take it along as a desk reference
when you enter the profession. The amount of written
text is complete but kept to a minimum. Examples and
illustrations are used extensively. Drafting is a graphic
language, and most drafting students learn best by
observation of examples. Here are a few helpful hints
for using this textbook:
1. Read the text. The text content is intentionally
designed for easy reading. Content is given in as few,
easy-to-understand words as possible. You should
xxi
do the reading because the content can help you to
understand the drawings clearly.
2. Look carefully at the examples. The figure examples
are presented in a manner that is consistent with
architectural drafting standards and the U.S. National
CAD Standard. Look at the examples carefully in an
attempt to understand specific applications. If you
are able to understand why something is done a
certain way, it will be easier for you to apply the concepts to the drawing problems in this textbook and to
the similar issues when working as an architectural
drafter. Drafting is a precise technology based on
standards and guidelines. The goal of a drafter is to
prepare drawings that are easy to read and understand. There are times when rules need to be altered
to handle a unique situation. Rely on judgment based
on your knowledge of accepted standards in these
situations. Drafting is often like a puzzle—there is
often more than one way to solve a problem.
3. Use the text as a reference. Few drafters know every-
thing about drafting standards, techniques, and concepts. Always be ready to use this textbook as the
reference if you need to verify how a specific application is handled. Become familiar with the definitions
and use of technical terms. It is difficult to memorize
everything in this text, but architectural drafting
applications should become second nature as you
gain experience.
4. Learn each concept and skill before you continue to
the next. The text is presented in a logical learning
sequence. Each chapter is designed for learning
development, and chapters are sequenced so drafting knowledge grows from one chapter to the next.
Problem assignments are presented in the same
learning sequence as the chapter content and also
reflect progressive levels of difficulty.
5. Practice. Development of good manual and comput-
er-aided drafting skills depend to a large extent on
practice. Some individuals have an inherent talent for
manual drafting, and some people are readily compatible with computers. If you fit into either group,
great! If you have difficulty, then practice is all you
may need. Practice manual drafting skills to help
improve the quality of your drafting presentation,
and practice computer skills to improve your skills
and efficiency with communication and drafting.
6. Use sketches or preliminary drawings. When you are
drawing manually or with a computer, the proper use
of a sketch or preliminary drawing can save a lot of
time in the long run. Prepare a layout sketch or preliminary layout for each problem. This preliminary
xxii
step gives you a chance to organize thoughts about
drawing scale, view selection, dimension and note
placement, and sheet size. After you become an experienced drafter, you may be able to design a sheet
layout in your head, but until then, you should use
sketches.
7. Use professional equipment and materials. For the best
possible learning results and skill development, use
the professional drafting equipment, supplies, and
materials that are recommended.
ABOUT THE AUTHORS
Alan Jefferis
Alan Jefferis is Faculty Emeritus of Drafting Technology
at the Autodesk Premier Training Center at Clackamas
Community College in Oregon City, Oregon. He was an
architectural drafting and CAD instructor at Clackamas
Community College for over 30 years. He also taught
at Mt. Hood Community College in Gresham, Oregon,
for four years. In addition to community college experience, Jefferis had eight years of experience drawing for
architects, engineers, and residential designers prior to
working for 26 years as a professional building designer
as the principal of Residential Designs, a design firm
specializing in custom, energy-efficient homes. He is
also a former member of the American Institute of
Building Designers. In addition to his design work, he
is a coauthor of several standard reference works from
Cengage Delmar Learning including Residential Design
Drafting and Detailing; Print Reading for Architectural
Construction Technology; Commercial Drafting and
Detailing; and AutoCAD® for Architecture.
David A. Madsen
David A. Madsen is the President of Madsen Designs Inc.
(www.madsendesigns.com). Madsen is Faculty Emeritus
of Drafting Technology and the Autodesk Premier
Acknowledgments
Training Center at Clackamas Community College in
Oregon City, Oregon. He was an instructor and department chairperson at Clackamas Community College for
nearly 30 years. In addition to community college experience, Madsen was a drafting technology instructor at
Centennial High School in Gresham, Oregon. He is a
former member of the American Design and Drafting
Association (ADDA) Board of Directors, and was honored by the ADDA with Director Emeritus status at the
annual conference in 2005. He has extensive experience
in mechanical drafting, architectural design and drafting, and building construction. Madsen holds a Master
of Education degree in Vocational Administration and
a Bachelor of Science degree in Industrial Education.
He is the author of Engineering Drawing and Design;
Geometric Dimensioning and Tolerancing; Print Reading
for Engineering and Manufacturing Technology; and
coauthor of Architectural Drafting and Design, and Print
Reading for Architecture and Construction Technology, as
well as many other drafting and CAD titles.
David P. Madsen
David P. Madsen is the Vice President of Madsen Designs
Inc. (www.madsendesigns.com), and operates the Madsen
Designs Inc. consulting service. He has been a professional design drafter since 1996, and has extensive
experience in a variety of drafting, design, and engineering disciplines. Madsen has provided drafting and
computer-aided design and drafting instruction to
secondary and postsecondary learners since 1999, and
has considerable curriculum, and program coordination
and development experience. He holds a Master of
Science degree in Educational Policy, Foundations, and
Administrative Studies with a specialization in Postsecondary, Adult, and Continuing Education; a Bachelor
of Science degree in Technology Education; and an
Associate of Science degree in General Studies and
Drafting Technology. Madsen is also the coauthor of
Engineer Drawing and Design and has authored and
coauthored other drafting and CAD titles.
Prologue
Preface
HOW TO USE THE STUDENT CD
Chapter Tests
Pick one of the following links to open. The
content of each link is described below.
Chapter tests are found at the end of each chapter. Pick
the Chapter Tests link to access chapter tests using
Microsoft Word. The chapter tests allow you to review
or test your knowledge of the related chapter content,
depending on your course objectives. Open the related
link and answer the questions electronically, unless
otherwise directed by your instructor.
●
Supplemental Chapter Readings
●
Step-by-Step Layout Drawings
●
Chapter Tests
●
Drawing Checklists
●
Drawing Problems
●
Drawing Templates
●
Architectural Blocks and Symbols
●
Related Web Links
●
Workbook
●
Video Clips of Major Concepts
●
Review Questions
Supplemental Chapter Readings
Throughout this textbook, a Student CD icon guides
you to chapter-related content provided for additional
reading and research. The Supplemental Chapter
Reading features found on the Student CD include
chapter-related content, basic information, advanced
content that is beyond the scope of the main textbook, and commonly used abbreviations.
Step-by-Step Layout Drawings
Several chapters throughout this textbook use the same
model home to describe step-by-step techniques for
laying out drawings required in a set of residential working drawings. Click the Step-by-Step Drawings link to
view Acrobat Portable Document Format (PDF) files of
many of the textbook figures related to the step-by-step
layout process. Use the files to display the figures on
your computer screen, and to look more closely at the
layout steps and details.
Drawing Checklists
Drawing checklists are provided for the model home
layout chapters throughout this textbook. The checklists allow you to check your work to be sure everything
is included in the drawing that you are completing.
Drawing Problems
The Chapter 18 drawing problems are found on the
Student CD. These problems are identified in the textbook with a Student CD icon. The Chapter 18 drawing
problems can be used for creating the floor plans of the
selected or assigned house that continue throughout
this textbook to create a set of working drawings.
Drawing Templates
Select the Drawing Templates link to access a page containing a link to architectural and civil AutoCAD drawing template (.dwt) files. Use the Drawing Templates
link and the available drawing template files to create
new drawings, as a resource for drawing content, or
for inspiration when developing your own templates.
The architectural drafting templates are set up to allow
you to prepare architectural drawings, whereas the civil
drafting templates include preset civil drawing content
for site plans and other civil drafting projects. Use the
(U.S.) templates to draw using U.S. customary, or feet
and inch, units. Use the (metric) templates to draw
using metric units. Each template includes a variety
xxiii
xxiv
of appropriate drawing settings and content, such as
layers, layouts, and object styles. You can also use a
utility such as DesignCenter, to add content from the
drawing templates to your own drawings and templates.
Consult with your instructor to determine which template drawing and drawing content to use.
Architectural Blocks and Symbols
The Architectural Symbols link provides access to an
AutoCAD drawing (.dwg) file that contains several
common architectural drafting symbols. These symbols are stored in folders named for the drawings in
which they are most typically used. Many of the symbols are in AutoCAD block form and are drawn on
the 0 layer; others are common symbols that should
be made into blocks before inserting into the drawing. Use a utility such as DesignCenter, or copy and
paste, to add the blocks to your own drawings. Use
the blocks as desired or as directed by your instructor.
Additional symbols are available through a variety of
resources. Some software programs, such as AutoCAD,
include and allow you to access many architectural
symbols. Many other symbols are available through
the Internet for free download or purchase. The U.S.
National CAD Standard (NCS) include separate .dwg
files of the symbols presented in the standard.
Related Web Links
Internet research is an excellent way to gain additional knowledge about architectural drafting and
the professional organizations related to architectural
drafting and design. The Related Web Links section
contains a variety of related Web site links for you to
explore as preferred or as directed by your instructor.
The Web site links are provided in alphabetical order
covering the entire textbook content, and chapterby-chapter. Click a link to go automatically to the
designated Web site.
Workbook
Additional problems have been provided to reinforce
the knowledge and skills introduced throughout the
Prologue
textbook. These problems are divided into these Sections
and Chapters:
Section I: Basic Residential Projects
Chapter 1 Basic Architectural Drafting Practices
Chapter 2 Site Plans
Chapter 3 Floor Plan Fundamentals
Chapter 4 Basic Floor Plan Problems
Chapter 5 Floor Plan Dimensions
Chapter 6 Electrical Plans
Chapter 7 Plumbing and HVAC Plans
Chapter 8 Roof Plans
Chapter 9 Elevations
Chapter 10 Cabinet Elevations
Chapter 11 Foundation Plans
Chapter 12 Details
Chapter 13 Sections
Chapter 14 Stair Sections
Chapter 15 Fireplace Sections
Chapter 16 Design Criteria for Structural Loading
Chapter 17 Construction Specifications, Permits,
and Contracts
Chapter 18 Presentation Drawings
Section II: Advanced Residential Projects
Section III: Additional Advanced Residential Projects
Section IV: Advanced Research Projects
Video Clips of Major Concepts
This feature provides a variety of video clips covering
major concepts presented throughout the textbook.
These video clips provide you with an alternate learning
and study option covering a variety of topics.
Review Questions
This feature provides you with review questions that
are in addition to the chapter-by-chapter test questions
provided throughout the textbook. Use the review questions for additional opportunities to test your knowledge and review textbook content.
www.kevinmillerphoto.com
SECTION 1
Introduction to
Architectural
Design and
Drafting
This page intentionally left blank
CHAPTER 1
Professional Architectural
Careers, Office Practices,
and Opportunities
I
N
T
R
O
D
U
C
T
I
O
N
As you begin working with this text, you are opening the door
to many exciting careers. Each career in turn has many different
opportunities within it. Whether your interest lies in theoretical
problem solving, artistic creations, or working with your hands
creating something practical; a course in architectural drafting
and design will help you satisfy that interest. An architectural
drafting class can lead to a career as a drafter, CAD technician,
designer, interior decorator, interior designer, architect, or engineer. Mastering the information and skills presented in this text
will prepare you for jobs as a drafter or CAD technician and serve
as a solid foundation for each of the other listed professions as
well as many others.
DRAFTER
A drafter is the person who creates the drawings and
details for another person’s creations. It is the drafter’s
responsibility to use the proper line and lettering quality
and to properly lay out the required drawings necessary to complete a project. Such a task requires great
attention to detail as the drafter draws the supervisor’s
sketches. Although the terms are used interchangeably,
professionals often use the term drafter to refer to a
person who draws manually using pencils or pens. The
term CAD technician is used to describe a person who
creates the same type of drawings using a computer.
Throughout this book, the term drafter will be used to
describe both those who draw manually and those who
create drawings using a computer.
The Beginning Drafter
Your job as a beginning or junior drafter will generally
consist of making corrections to drawings created by
others. There may not be a lot of mental stimulation
to making changes, but it is a very necessary job. It is
also a good introduction to the procedures and quality
standards within an office.
As your line and lettering quality improve, your
responsibilities will be expanded. If you’re working at
a firm that uses computers, in addition to mastering
basic CAD commands, you’ll need to become familiar
with the U.S. National CAD Standards (NCS). These
are guidelines assembled by the National Institute of
Building Sciences (NIBS) that incorporate the Uniform
Drawing System (UDS) published by the Construction
Specifications Institute (CSI), CAD Layer Guidelines
published by the American Institute of Architects, and
the U.S. Coast Guard. These guidelines are aimed at
bringing uniformity between consulting firms to ensure
quality plans. Future chapters in this text will introduce key concepts from the NCS. You’ll also need to
become proficient using the firm’s computer standards
and any special menus and list-processing language
(LISP) routines needed to work efficiently.
No matter what tools are used to create the drawings,
typically your supervisor will give you a sketch and
expect you to draw the required drawing. Figure 1-1
shows a project manager’s sketch. Figure 1-2 shows
the drawing created by a drafter. As you gain an
3 X 6 PT SILL
SOLID BLOCK
W/ A-35 ANGLE
W16 X 67
5/16
12 X 12 X 3/4"
STEEL TOP PL.
3/8
4
5/16
1/4
T.S. 6 X 6 X 1/4"
6 X 6 X 3/8"
SIDE PLATE
3/4" o TIE RODS &
3/4" TURNBUCKLES
FIGURE 11 A sketch created by the project manager is usually
given to a junior drafter to follow for a first drawing. The drafter
can find information for completing the drawing by examining
similar jobs in the office.
3
4
Architectural Drafting and Design
SOLID BLOCK
W/ A-35 ANGLE
@ EA. JOIST AND
EVERY OTHER
BLOCK TO PL.
W16 X 67
3 X 6 PT SILL W/
1/2" o M.B.
24" O.C. STAGGER
The Experienced Drafter
5/16
12 X 12 X 3/4"
STEEL TOP PL.
3/8
4
5/16
1/4
T.S. 6 X 6 X 1/4"
STEEL COLUMN
TYPICAL
office chores. Don’t get the idea that a drafter does only
the menial chores around an office. But you do need to
be prepared, as you go to your first drafting job, to do
things other than drafting.
6 X 6 X 3/8"
SIDE PLATE
3/4" o TIE RODS &
3/4" TURNBUCKLES
1 FLOOR / GIRDER / PILING
R6010309
500 3/4" = 1'–0"
FIGURE 12 A detail drawn by a drafter using the sketch
shown in Figure 1-1.
understanding of the drawings that you are making and
gain confidence in your ability, the sketches that you are
given generally will become more simplified. Eventually
your supervisor may just refer you to a similar drawing
and expect you to be able to make the necessary adjustments to fit it to the new application.
The decisions involved in making drawings without
sketches require the drafter to have a good understanding of what is being drawn. This understanding does not
come from a textbook alone. To advance as a drafter and
become a leader on the drawing team will require you
to become an effective manager of your time. This will
include the ability to determine what drawings need to
be created, selected from a stock library, and edited; and
to estimate the time needed to complete these assignments and meet deadlines established by the team
captain, the client, the lending institution, or the building department. An even better way to gain an understanding of what you are drafting is to spend time at a
construction site watching projects that you’ve worked
on become reality. Gaining an understanding of what
a craftsperson must do as a result of what you have
drawn will greatly aid you as you assume more responsibility on projects.
Depending on the size of the office where you work,
you may also spend a lot of your time as a beginning
drafter editing stock details, running prints, making
deliveries, obtaining permits, and doing other such
Although your supervisor may prepare the basic design
for a project, experienced drafters are expected to
make decisions about construction design. These decisions might include determining structural sizes and
connection methods for intersecting beams, drawing
renderings, visiting job sites, and supervising beginning
drafters. As you gain experience, you will be assigned
drawings that are more complex. Instead of revising
existing details or drawing site plans, cabinet elevations, or roof plans; an experienced drafter and team
leader may be working on the floor and foundation
plans, elevations, and sections. Your supervisor probably will still make the initial design drawings, but
will pass these drawings on to you as soon as a client
approves the preliminary drawings.
In addition to drafting, you may work with the
many city and state building departments that govern
your work. This will require you to research the codes
that govern the building industry. You will also need
to become familiar with vendors’ catalogs. The most
common is the Sweets Catalog. Sweets, as it is known,
is a series of books that contain product information
on a wide variety of building products. Sweets is also
available on the Internet or on CDs that are updated
quarterly. Information in these catalogs is listed by
manufacturer, trade name, and type of product.
Educational Requirements
In order to get your first drafting job, you will need a
solid education, good computer-aided drafting (CAD)
skills, a good understanding of basic computer skills,
and the ability to sell yourself to an employer. CAD
skills must include a thorough understanding of
drawing and editing commands, as well as the ability
to quickly decide which option is best for the given
situation. This ability will also come with practice.
If you work full-time editing details, you’ll quickly
become proficient at determining the best commands
to use. The education required for a drafter can range
from one or more years in a high school drafting
program to a diploma from a one-year accredited
technical school to a degree from a two-year college program, and all the way to a master’s degree in
architecture.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
Helpful areas of study for an entry-level drafter
include math, writing, and drawing. The math required
ranges from simple addition to calculus. Although the
drafter may spend most of the day adding dimensions
expressed in feet and inches, knowledge of advanced
math will be helpful for solving many building problems. You’ll often be required to use basic math skills
to determine quantities, areas, and volume. Many firms
provide their clients with a list of materials required to
construct the project. Areas will need to be calculated
to determine the size of each room, required areas to
meet basic building code requirements, the loads on a
structural member, or the size of the structure. Writing
skills will also be very helpful. As a drafter, you are often
required to complete the paperwork that accompanies
any set of plans, such as permits, requests for variances,
written specifications, or environmental impact reports.
In addition to standard drafting classes, classes in photography, art, surveying, and construction can be helpful
to the drafter.
Personal Requirements
In addition to a solid education, professionals working in the design field need to function well in group
settings. Because the drafter will generally be working
for several architects or engineers within an office, the
drafter must be able to get along well with others. An
additional skill required for a new technician is to be
reliable. Reliability within an office is measured by the
maintenance of good attendance patterns and the production of drawings as scheduled.
To advance and become a good team leader you will
also need to develop skills that promote a sense of success among your teammates. Although it is against the
law to discriminate on the basis of race, color, religion,
gender, sexual orientation, age, marital status, or disability, moving beyond the law and creating a friendly
and productive work environment is a critical skill for
a team leader.
Workplace Ethics
A key quality required in any of the design professions
that you might enter is to be ethical. Ethics are rules
and principles that define right and wrong conduct.
Although ethics guidelines can be as simple as treating
others as you would like to be treated, many businesses
have a formal code of ethics that employees are required
to sign in order to obtain a job. A code of ethics is a
formal document that states an organization’s values
and the rules and principles that employees are expected
5
to follow. In general, codes of ethics contain these main
elements: be dependable, obey the laws, and be good to
customers. An example of an architectural firm’s standard for ethical business conduct can be seen below:
1. Honesty: to be truthful in all our endeavors, to be
honest and forthright with one another, with our
customers, and with our communities.
2. Integrity: to say what we mean, to deliver what we
promise, and to stand for what is right.
3. Respect: to treat one another with dignity and fairness, appreciating the diversity of our workforce and
the uniqueness of each employee.
4. Trust: to build confidence through teamwork and
open, candid communication.
5. Responsibility: to speak up, without fear of retribution, and report concerns in the workplace, including
violations of published or unpublished works that
are copyrighted.
Copyright Protection
Clients often come to an architectural firm hoping to
use the plan of a competitor as the basis for the design
for their project. It’s important to understand that
architectural drawings are protected by copyright. The
copyright immediately becomes the property of the
person who created the work. Copyright is secured
automatically when the work is created, and the work
is created when it is fixed in a copy for the first time.
Copies are material objects from which the work can
be read or visually perceived either directly or with the
aid of a machine or device. In the world of architecture,
you’ll be most affected by copyright laws as clients
present you with plans from magazines, and ask you
to recreate the design. There is nothing illegal when a
client gives you several stock plans, and expects you
to combine features from these plans into a new plan.
However, it is very illegal to take one stock plan, make
minor changes, and pass it off as your design. That’s
copyright infringement.
NOTE: Professional designers and architects have donated
the plans in this book knowing that they will be copied
and redrawn. It is perfectly legal for you to reproduce
these plans for school projects. It is important to realize
though, it is not OK to reproduce these drawings for resale.
Laws vary for each state, but as a general rule, unless
you’ve changed more than 50% of the plan, or significantly
altered the appearance of the design, you may be found
guilty of copyright infringement. Never take the plan from
another professional, make minor changes, and then call it
your design. It’s lazy, unethical, and illegal.
6
Architectural Drafting and Design
Employment Opportunities
Drafters can find employment in firms of all sizes.
Designers, architects, and engineers all require entrylevel and advanced drafters to help produce their
drawings. Drafters are also employed by suppliers of
architectural equipment. This work might include drawing construction details for a steel fabricator, making
layout drawings for a cabinet shop, or designing ductwork for a heating and air-conditioning installer. Many
manufacturing companies hire drafters with an architectural background to help draw and sometimes sell
a product or draw installation diagrams for instruction
booklets or sales catalogs. Drafters are also employed
by many government agencies. These jobs include
working in planning, utility, or building departments;
survey crews; or other related municipal jobs.
DESIGNER
The meaning of the term designer varies from state to
state. Many states restrict its use by requiring those
calling themselves designers to those who have had
formal training and have passed a competency test. A
designer’s responsibilities are very similar to those of
an experienced drafter and are usually based on both
education and experience. A designer is usually the
coordinator of a team of drafters. The designer may
work under the direct supervision of an architect, an
engineer, or both and supervise the work schedule of
the drafting team.
In addition to working in a traditional architectural
office setting, designers often have their own office
practice in which they design residential, multifamily,
and some types of light commercial buildings. State
laws vary regarding the types and sizes of buildings
a designer may work on without an architect or
engineer’s stamp. For more information about design
careers, contact:
American Institute of Building Design
991 Post Road East
Westport, CT 06880
800-366-2423
Web site: www.aibd.org
INTERIOR DECORATOR
An interior decorator decorates the interiors of buildings, with the aim of making rooms more attractive,
comfortable, and functional. Most interior decorators are hired to decorate homes, but they may also
be hired to decorate interiors of businesses such as
boutiques, restaurants, and offices. They may work
on the entire interior of a building or a single room.
An interior decorator’s work may involve a variety of
elements, including space planning, determination of
color schemes, furniture placement, and the coordination of interior finishes such as paint and wallpaper,
window coverings, and flooring. It may also include
the arrangement of lighting fixtures, art objects, furnishing accessories, and interior plants. Specific job
requirements may include:
●
Meeting with clients to determine the scope of a
project.
● Reviewing and measuring the space to be decorated.
● Preparing proposed room layouts and obtaining
cost estimates.
● Providing samples and colors of materials to be used.
● Arranging and overseeing painting, wallpapering,
and flooring.
● Selecting and purchasing furnishings and other
items.
There are no formal educational requirements to
enter this career. You can start calling yourself an
interior decorator as soon as you start doing interior
decorating.
KITCHEN AND BATH DESIGNER
Some drafters and designers choose to specialize in
the area of residential kitchen and bath design. This
might include design work for a client, working with a
residential contractor, or working with manufacturers
of kitchen and bath equipment. In order to meet the
demand for qualified professionals in this area of design,
the National Kitchen & Bath Association (NKBA) has
created its own training program that offers the foundation for professional career growth through its course
offerings, technical manuals, and multilevel certification
programs. The three professional levels in which the
NKBA certifies its members, and the requirements of
each level are:
●
Associate Kitchen & Bath Designer (AKBD)—One
year of experience related to the kitchen and bath
industry and one year in a related field, 30 hours of
NKBA professional development training, and successful completion of the AKBD exam.
● Certified Kitchen Designer (CKD) or Certified
Bathroom Designer (CBD)—Three years of experience related to the kitchen and bath industry and
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
four years in a related field, 60 hours of NKBA
professional development training, and successful
completion of the AKBD exam.
● Certified Master Kitchen & Bathroom Designer
(CMKBD)—Ten years of experience related to the
kitchen and bath industry, 100 hours of NKBA professional development training, and both CKD and
CBD certification.
For further information about careers in the field of
kitchen and bath design, contact:
National Kitchen & Bath Association
687 Willow Grove Street
Hackettstown, NJ 07840
800-843-6522
Web site: www.nkba.org
INTERIOR DESIGNER
An interior designer works with the structural
designer to optimize and harmonize the interior
design of structures. In addition to health and safety
concerns, interior designers help plan how the space
will be accessed, how a space will be used, the amount
of light that will be required, acoustics, seating, storage, and work areas. An interior designer must consider how the visual, tactile, and auditory senses of
the occupants will be impacted. Visual considerations
include the study and application of color, lighting,
and form to improve how the occupants function in
the space. Consideration must be given to the design
of surfaces, the shape of individual rooms within a
structure, and the texture of finished surfaces and
how furnishing will affect the usage of areas within
a structure. The design of a structure must also be
considered in relation to how noise and echo will be
created and how they can be controlled. An interior
designer must have an aesthetic, practical, and technical appreciation for how people use and respond to
these elements and to how the elements interact with
one another.
Interior designers must also be knowledgeable
about the many types and characteristics of furnishings, accessories, and ornaments used in creating
interiors. Furniture, lighting, carpeting and other floor
coverings, paint and wall coverings, glass, wrought
metal, fixtures, art, and artifacts are some of the many
items and materials designers select. In addition, they
must be familiar with the various styles of design, art,
and architecture and their history. Interior designers
provide a variety of services that include:
7
●
Consulting to help determine project goals and
objectives.
●
Generating ideas for aesthetic possibilities of the
space, and arranging space to suit its intended
function.
●
Creating illustrations and renderings of proposals.
●
Developing documents and specifications related
to interior spaces in compliance with applicable
building codes.
●
Specifying colors and purchasing fixtures, furnishings, products, and other interior materials.
●
Designing and managing fabrication of custom
furnishings and interior details.
●
Monitoring and managing construction and installation of the design.
Although a college degree is currently not a requirement, the trend among employers and in states that
have licensing requirements is to require a degree
from an accredited institution. This can range from
training in a two-year program to earn an associate’s
degree or certificate, to a four- or five-year program
leading to a bachelor’s (BA, BS, BFA) or master’s (MA,
MS, MFA) degree. The option chosen may depend on
the licensing requirements in your state and whether
you have completed a degree in another field.
In the United States, where interior designers are
registered by title, designers may not use the title
“interior designer” or “registered interior designer”
unless they have met the requirements for education,
experience, and examination as set forth in the statutes established by the National Council for Interior
Design Qualification (NCIDQ). Candidates who apply
to take the NCIDQ examination must demonstrate
an acceptable level of professional work experience
and completion of related course work. The minimum
examination requirements include two years of formal
interior design experience and four years of full-time
work experience in the practice of interior design.
Passing the examination is required in twenty jurisdictions in the United States and eight provinces in
Canada that regulate the profession of interior design.
For further information about careers in the field of
interior design, contact:
American Society of Interior Designers (ASID)
202-546-3480
Web site: www.asid.org
International Interior Design Association (IIDA)
Web site: www.iida.org
8
Students can also contact the American Design and
Drafting Association, the U.S. Department of Labor, or
the U.S. Office of Education.
ARCHITECT
An architect is a licensed professional who designs
commercial and residential structures. Architects
perform the tasks of many professionals, including
designer, artist, project manager, and construction
supervisor. Few architects work full-time in residential
design. Although many architects design some homes,
most devote their time to commercial construction
projects such as schools, offices, and hospitals. An
architect is responsible for the design of a structure and
for the way the building relates to the environment.
The architect often serves as a coordinator on a project
to ensure that all aspects of the structure blend together
to form a pleasing relationship. This coordination
includes working with the client, the contractors, and
a multitude of engineering firms that may be involved
with the project. Figure 1-3 shows a home designed by
an architect to blend the needs and wishes of the client
with the site, materials, and financial realities.
Education
High school and two-year college students can prepare
for a degree program by taking classes in fine arts,
math, science, and social science. Many two-year drafting programs offer drafting classes that can be used
FIGURE 13 Architects use their training to blend the needs
and wishes of the client with the site, materials, and financial
realities. Courtesy California Redwood Assoc., Robert Corna architect,
photo by Balthazar Korab.
Architectural Drafting and Design
for credit in four- or five-year architectural programs.
A student planning to transfer to a four-year program
should verify with the new college which classes can be
transferred. Depending on the desired field of practice,
students will eventually need to complete the requirements for a bachelor of architecture, master’s of architecture, or a doctorate of architecture degree.
Fine arts classes such as drawing, sketching, design,
and art along with architectural history will help
the future architect develop an understanding of the
cultural significance of structures and help transform
ideas into reality. Classes that will aid problem-solving
abilities, as well as math and science classes, including
algebra, geometry, trigonometry, and physics, will provide a stable base for the advanced structural classes
that will be required. Sociology, psychology, cultural
anthropology, and classes dealing with human environments will help develop an understanding of the
people who will use the structure. Because architectural students will need to read, write, and think
clearly about abstract concepts, preparation should also
include literature and philosophy courses. In addition
to formal study, students should discuss with local
architects the opportunities and possible disadvantages
that may await them in pursuing the study and practice
of architecture.
Positions in Architectural Firms
Use of the term architect is legally restricted to individuals who have been licensed by the state where they
practice. Once the required degree has been completed,
obtaining a license will require practical experience
working under the supervision of a licensed architect.
A typical path to becoming an architect requires three
years to complete a master’s program, three years as an
intern, and two years to complete the registration exam
process. Some states allow a designer to take the licensing test through practical work experience. Although
standards vary for each state, five to seven years of
experience under the direct supervision of a licensed
architect or engineer is usually required.
Positions in an architectural firm include:
Technical staff—Consulting engineers such as
mechanical, electrical, and structural engineers; landscape architects; interior designers; CAD operators;
and drafters.
Intern—Unlicensed architectural graduates with less
than three years of experience. An intern’s responsibilities typically include developing design and
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
technical solutions under the supervision of an
architect.
Architect I—Licensed architect with three to five
years of experience. An Architect I’s job description typically includes responsibility for a specific
portion of a project within the parameters set by a
supervisor.
Architect II—Licensed architect with six to eight
years of experience. An Architect II’s job description
typically includes responsibility for the daily design
and technical development of a project.
Architect III—Licensed architect with eight to ten
years of experience. An Architect III’s job description
typically includes responsibility for the management
of major projects.
Manager—Licensed architect with more than
10 years of experience. A Manager’s responsibilities
typically include management of several projects,
project teams, and client contacts, as well as project
scheduling and budgeting.
Associate—Senior management architect, but not
an owner in the firm. This person is responsible for
major departments and their functions.
Principal—Owner/partner in an architectural firm.
Areas of Study
The study of architecture is not limited to the design of
buildings. Although the architectural curriculum typically is highly structured for the first two years of study,
students begin to specialize in an area of interest during
the third year of the program.
Students in a bachelor’s program may choose courses
leading to a degree in several different areas of architecture such as urban planning, landscape architecture,
and interior architecture. Urban design is the study of
the relationship among the components within a city.
Interior architects work specifically with the interior of
a structure to ensure that all aspects of the building will
be functional. Landscape architects specialize in relating the exterior of a structure to the environment. For
further information on training or other related topics,
students can contact:
American Institute of Architects (AIA)
1735 New York Avenue NW
Washington, DC 20006
800-242-3837
Web site: www.aia.org
9
American Society of Landscape Architects (ASLA)
636 Eye Street NW
Washington, DC 20001
202-898-2444
Web site: www.asla.org
ENGINEER
The term engineer covers a wide variety of professions.
In general, an engineer is a licensed professional who
applies mathematical and scientific principles to the
design and construction of structures. In the construction fields, structural engineers are the most common,
although many jobs exist for electrical, mechanical, and
civil engineers. Structural engineers typically specialize in the design of structures built of steel or concrete
(see Figure 1-4). Many directly supervise drafters and
designers in the design of multifamily and light commercial structures.
Electrical engineers work with architects and structural engineers and are responsible for the design of
lighting and communication systems. They supervise
the design and installation of specific lighting fixtures,
telephone services, and requirements for computer
networking.
Mechanical engineers are also an instrumental
part of the design team. They are responsible for the
sizing and layout of heating, ventilation, and airconditioning systems (HVAC) and plan how treated
air will be routed throughout the project. They work
with the project architect to determine the number of
FIGURE 14 The architectural team determines the shape
and style of the structure. The structural engineering team is
responsible for determining the size of materials to resist the
loads and stress that a building will face. Courtesy David Jefferis.
10
Architectural Drafting and Design
occupants of the completed building and the heating
and cooling load that will be generated.
Civil engineers are responsible for the design and
supervision of a wide variety of construction projects, such as highways, bridges, sanitation facilities,
and water treatment plants. They are often directly
employed by construction companies to oversee the
construction of large projects and to verify that the
specifications of the design architects and engineers
have been carried out.
As with the requirements for becoming an architect, a license is required to function as an engineer.
Potential engineers can apply for the license after
several years of practical experience, or after obtaining a bachelor’s degree and three years of practical
experience.
Success in any of the engineering fields requires high
proficiency in math and science, and involves completing courses in physics, mechanics, print reading, architecture, mathematics, and material science. As with the
requirements for becoming an architect, an engineer
must have five years of education at an accredited
college or university, followed by successful completion of a state-administered examination. Certification
can also be accomplished by training under a licensed
engineer and then successfully completing the examination. Additional information can be obtained about
engineering by writing to:
New York, NY 10005
212-248-5000
Web site: www.iesna.org
RELATED FIELDS
So far, only opportunities that are similar because
they involve drawing, design, and creativity have been
covered. In addition to these careers, there are many
related careers that require an understanding of drafting principles. These include model maker, illustrator,
specification writer, plan examiner, inspector, and
construction-related trades.
Model Maker
In addition to presentation drawings, many architectural offices use models of a building or project
to help convey design concepts. Models such as the
one shown in Figure 1-5 are often used as a public
display to help gain support for large projects.
Model makers need basic drafting skills to help
interpret the plans required to build the actual project. Model makers may be employed within a large
architectural firm or may work for a company that
only makes models for architects. For more information, contact the Association of Model Makers at
www.modelmakers.org.
American Society of Civil Engineers (ASCE)
1801 Alexander Bell Drive
Reston, VA 20191-4400
800-548-2723
Web site: www.asce.org
American Consulting Engineers Council (ACEC)
1015 15th Street, NW, Suite 802
Washington, DC 20005
202-347-7474
Web site: acec.org
American Society of Heating, Refrigerating, and Air
Conditioning Engineers, Inc. (ASHRAE)
1791 Tullie Circle NE
Atlanta, GA 30329-2305
800-527-4723
Web site: www.ashrae.org
Illuminating Engineering Society of North America
(IESNA)
120 Wall Street, 17th Floor
FIGURE 15 Models such as this one of the KOIN Center in
Portland, Oregon, are often used in public displays to convey
design ideas. Courtesy KOIN Center, Olympia & York Properties
(Oregon) Inc.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
11
the architectural world to assign reference numbers
to architectural materials and products. The numbers
consist of 17 groups, 5 major subgroups, and 50 divisions. These listings can be used for production, distribution, filing, and retrieval of construction documents.
Each major division of the MasterFormat system is
related to a major grouping of the construction process
and will be introduced in Chapter 8.
Plan Examiner
FIGURE 16 Drawings created by an architectural illustrator are
often used for advertising and presentation purposes. Courtesy
Bob Greenspan, Alan Mascord Design Associates, Inc.
Illustrator
Many drafters, designers, and architects have the
basic skills to draw architectural renderings. Very few,
though, have the expertise to make this type of drawing
rapidly. Most illustrators have a background in art. By
combining artistic talent with a basic understanding
of architectural principles, the illustrator can produce
drawings that show a proposed structure realistically.
Figure 1-6 shows a drawing that was prepared by an
architectural illustrator. Section 11 provides an introduction to presentation drawings. For more information, contact the American Society of Architectural
Illustrators (ASAI) at www.asai.org.
Specification Writer
Specifications are written instructions for methods,
materials, and quality of construction. A written
specification for a product may range from a sentence or two describing a price range of a product, to
a lengthy document that specifies how a product is to
be purchased, delivered, stored, installed, maintained,
and recycled at the end of its use. Generally, a writer
will have had classes in technical writing at the twoyear-college level. A specification writer must have a
thorough understanding of the construction process
and the use of the CSI 2004 MasterFormat numbering system, and have a good ability to read plans. The
MasterFormat system is published by the Construction
Specification Institute (CSI) in the United States,
and by Construction Specifications Canada (CSC) in
Canada. The numbering system is used by all areas of
Building departments require that plans be checked
carefully to ensure that the required codes for public
safety have been met. A plan examiner must be licensed
by the state, to certify minimum understanding of the
construction process. In most states, there are different
levels of examiners. An experienced drafter or designer
may be able to qualify as a low-level or residentialplan inspector. Generally, a degree in engineering or
architecture is required to advance to an upper-level
position. Additional information on how to become a
plan examiner can be obtained from the International
Code Council at www.iccsafe.org.
Inspector
The construction that results from the plans must also
be inspected. Depending on the size of the building
department, the plan examiner may also serve as the
building inspector. In large building departments, one
group examines plans and another inspects construction. Being be a construction inspector requires an
exceptionally good understanding of code limitations,
print reading, and construction methods. Each of
these skills has its roots in a beginning drafting class.
Additional information regarding becoming a building
inspector can be obtained from the International Code
Council at www.iccsafe.org.
Jobs in Construction
Many drafters are employed directly by construction
companies. The benefits of this type of position have
already been discussed. These drafters typically not only
do drafting but also work part-time in the field. Some
drafters give up their jobs for one of the high-paying
positions in the construction industry. The ease of
interpreting plans as a result of a background in drafting
is of great benefit to any construction worker.
12
GOING
GREEN
An Introduction to Green Design
Reduce, reuse, recycle! No matter what area of the design
or construction field you enter, an important aspect of
your career will be a building mind-set that revolves around
these three words. Whether it is called earth-friendly, green,
ecological, or sustainable construction, the concept is to build
in a manner that will produce a structure that uses energy
efficiently, that uses materials that have low impact on the
environment, and that contributes to a healthier workplace.
One of the leaders in the development of sustainable
construction is the Leadership in Energy and Environmental
Design Green Building Rating System, referred to as
LEED. LEED is a rating system used to evaluate key areas
of building projects, such as:
•
•
•
•
•
•
Sustainable sites.
Water efficiency.
Indoor environmental quality.
Energy and atmosphere.
Material and resources.
Innovation and the design process.
Other key organizations that are leaders in green
construction include the developed by the National
Association of Home Builders (NAHB), American National
Standards Institute (ANSI), and the International Code
Council (ICC) that publishes the International Residential
Code (IRC). The IRC will be introduced in Chapter 9. These
three industry leaders have combined their resources to
develop the National Green Building Standards (ICC 7002008). The NGBS are currently a group of guiding principles
that can be used throughout the construction process to
ensure an environmentally friendly project. It is expected
that these current guidelines will become mandatory as
part of the ICC code family as the 2012 codes are released.
Major principles addressed by the 2008 guidelines include:
• Site design and development.
• Site design, preparation, and development.
DESIGN BASICS
As you enter the world of design, it’s important to
understand what you can expect to encounter in an
architectural office. Designing a home for a client can
be an exciting but difficult process. Very rarely can
an architect sit down and create a design that meets
the needs of the client perfectly. The time required to
design a home can range from a few days to several
months. It is important for you to understand the
design process and the role that the drafter plays in
it. This requires an understanding of basic design,
•
•
•
•
•
Resource efficiency.
Energy efficiency.
Water efficiency.
Indoor environmental quality.
Operation, maintenance, and building owner
education.
The LEED and NGBS principles will be introduced
throughout the text. As a new employee in a firm, you
may not be making the decisions on how to increase
the sustainability of a residence, but in order to advance
in an office, you must understand key green issues
presented in each of these guidelines.
Section 2 of this text will examine common methods
of designing a residence that is environmentally friendly.
Section 8 will examine common framing methods
found in residential construction. Environmentally
friendly framing is not just a matter of selecting green
materials; once selected, these green products must
be transported and used in a manner that will reduce
the environmental impact of the structure. Creating
an environmentally friendly structure requires the
matching of materials to a specific design and site that
minimizes the effect on that site. Five questions should
be considered that will affect the selection of materials
to make a sustainable structure:
1. Can products be selected that are made from
environmentally friendly materials?
2. Can products be selected because of what they do
not contain?
3. Will the products to be used reduce the environmental
impact during construction?
4. Will the products to be used reduce the environmental
impact of operating the building?
5. Will the products to be used contribute to a safe,
healthy indoor environment?
financial considerations, and common procedures of
design. In the balance of this chapter, the terms architect and designer can be thought of as synonymous.
Typically the designing and much of the drafting will
already be done before a project is given to the junior
drafter. As experience and confidence are gained, the
drafter enters the design process at earlier stages.
Financial Considerations
Both designers and drafters need to be concerned with
costs. Finances influence the drafter’s decisions about
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
framing methods and other structural considerations.
Often the advanced drafter must decide between
methods that require more materials with less labor
and those that require fewer materials but more labor.
The owner may never be aware of these decisions, but
the choices made can make the difference in whether
or not the house is affordable.
The designer makes the major financial decisions
that affect the cost and size of the project. The designer
needs to determine the client’s budget at the beginning
of the design process and work to keep the project
within these limits.
Through past experience and contact with builders, the designer should be able to make an accurate
estimate of the cost of a finished house. This estimate
is often made on a square footage basis in the initial
stages of design. For instance, in some areas a modest
residence can be built for approximately $75 per square
foot. In other areas this same house may cost approximately $150 per square foot. A client wishing to build a
2500 sq ft house could expect to pay between $187,500
and $375,000, depending on where it will be built.
Keep in mind that these are estimates. A square footage price tells very little about the home. In the design
stage, square footage estimates help set parameters for
the design. The estimate is based on typical cost for
previous clients. The price of materials such as lumber,
concrete, and roofing will vary throughout the year
depending on supply and demand. Basic materials will
typically account for approximately 50% of the project
cost. Finished materials are the part of the estimate that
will cause wide variation in the cost. If you have ever
been in a home supply store, you know that a toilet can
be purchased for between $30 and $300. Every item in
the house will have a range of possible prices. The final
cost of the project is determined once the house is completely drawn and a list of materials is prepared. With
a list of materials, contractors are able to make accurate
decisions about cost.
The source of finances can also affect the design
process. Certain lending institutions may require some
drawings that the local building department may not.
Federal Housing Administration (FHA) and Veterans
Administration (VA) loans often require extra forms,
drawings, and specifications that need to be taken into
account in the initial design stages.
The Client
Most houses are not designed for one specific family. In
order to help keep costs down, houses are often built in
subdivisions and designed to appeal to a wide variety
of people. One basic plan may be built with several
13
FIGURE 17 Stock plans are designed to appeal to a wide variety
of buyers. Courtesy Design Basics, Inc. Home Plan Design Service.
different options, thus saving the contractor the cost
of paying for several different complete plans. Sections
4, 6, and 7 will explore alternative designs to the home
presented throughout this text. Some families may
make minor changes to an existing plan. These modified stock plans allow the prospective home buyer a
chance to have a personalized design at a cost far below
that of custom-drawn plans (see Figure 1-7). If finances
allow, or if a stock plan cannot be found to meet their
needs, a family can have a plan custom designed.
The Design Process
The design of a residence can be divided into several
stages. These generally include initial contact, preliminary design studies, room planning, initial working drawings, final design considerations, completion of working
drawings, permit procedures, and job supervision.
Initial Contact
Clients often approach designers to obtain background
information. Design fees, schedules, and the compatibility of personalities are but a few of the basic questions
14
to be answered. This initial contact may take place
by telephone or a personal visit. The questions asked
are important to both the designer and the client. The
client needs to pick a designer who can work within
budget and time limitations. Drawing fees are another
important consideration in choosing a designer. Design
fees vary based on the type of project and the range of
services to be provided. Fees are generally based on
hourly rates, price per square feet of construction, on
a percentage of construction cost, or a combination of
these methods. Square footage prices vary based on the
size of the project and the area of the country, but must
be set to cover design and drafting time, overhead, and
profit margin. New drafters are often shocked to learn
that their office bills clients at a rate that is often three
to four times their hourly rate of pay for drafting time.
It is important to remember that this billing price must
include supervision time, overhead, state and federal
taxes, and hopefully a profit for the office. Design fees
for architectural services of a custom house range from
5% to 15% of the total construction cost. The amount
varies based on the services provided, the workload of
the office, and the local economy. The designer needs to
screen clients to determine if the client’s needs fit within
the office schedule.
Once an agreement has been reached, the preliminary
design work can begin. This selection process usually
begins with the signing of a contract to set guidelines
that identify which services are to be provided and
when payment is expected. This is also the time when
the initial criteria for the project will be determined.
Generally, clients have a basic size and a list of specifics
in mind, a sketch of proposed floor plans, and a file full
of pictures of items that they would like in their house.
During this initial phase of design it is important to
become familiar with the lifestyle of the client as well as
the site where the house will be built.
Preliminary Design Studies
Once a thorough understanding of the client’s lifestyle,
design criteria, and financial limits has been developed, the preliminary studies can begin. These include
research with the building and zoning departments that
govern the site, investigation of the site, and discussions
with any board of review that may be required. Once
this initial research has been done, preliminary design
studies can be started. The preliminary drawings usually
take two stages: bubble drawings and scaled sketches.
Bubble drawings are freehand sketches used to help
determine room locations and relationships. Several
sketches similar to Figure 1-8 are usually created. It is
during this stage of the preliminary design that consideration is given to the site and energy efficiency of
Architectural Drafting and Design
FIGURE 18 Bubble designs are the first drawings in the design
process. These drawings are used to explore room relationships.
the home by planning room orientation to the site, the
surroundings, the movement of the sun, and available
sunlight at the property at various times of the day.
Once a satisfactory layout has been sketched,
these shapes are transformed into scaled sketches.
Figure 1-9 shows a preliminary floor plan. Usually
several sets of sketches are developed to explore different design possibilities. Consideration is given to
building code regulations and room relationships and
sizes. After the design options are explored, the designer
selects a plan to prepare for the client. This could be the
point when a drafter first becomes involved in the design
process. Depending on the schedule of the designer, a
senior drafter might prepare the refined preliminary
drawings, which can be seen in Figure 1-10. These will
include floor plans and an elevation. These drawings
are then presented to the client. Changes and revisions
are made at this time. Once the plans are approved by
the client, the preliminary drawings are ready to be converted to design drawings.
Room Planning
Room usage must be considered throughout the design
process. Many professionals verify standard sizes by
using vendor catalogs and books such as Architectural
Graphic Standards. Chapter 10 will introduce major
design concepts to be considered. Typically the designer
will have talked with the owners about how each
room will be used and what types of furniture will be
included. Occasionally, placement of a family heirloom
will dictate the entire layout. When this is the case, the
owner should specify the size requirements for that particular piece of furniture.
15
S&P
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
14
FIGURE 19 Bubble drawings are converted to scale drawings so that basic sizes can be determined. The preliminary floor
plan contains enough text to convey ideas to the owner, but will require additional annotation to be added for the
construction process.
48" X 48" SKYLIGHT
5
300# COMPOSITION SHINGLES OVER 15# FELT
12
BRICK VENEER
2 X 6 FASCIA
6" HORIZ. CEDAR
FRONT ELEVATION
1/4"
1 X 3 CORN. TRIM
1'–0"
FIGURE 110 Based on preliminary floor plans, the front elevation is drawn to explore design options.
16
Architectural Drafting and Design
When placing furniture outlines to determine the
amount of space in a room, the drafter can use transfer
shapes known as rub-ons, templates, freehand sketching methods, or blocks if working with a CAD program.
Rub-ons provide a fast method of representing furniture
when manual methods are used, but they can also be
expensive. Furniture can be drawn with a template or
sketched. Figure 1-11 shows a preliminary floor plan
drawn with a CADD program with the furniture added
by the use of blocks.
In the final stages of the preliminary process, the
designer will often work with the clients, or bring in the
assistance of interior designers to start planning interior
finishes. With the interior space designed, attention can
now be focused on interior details. This might include
the use of interior elevations, interior perspectives, and
presentation boards. Presentation boards are used to
present samples of cloth or other materials that can be
used for wall finishes and furniture. Each element will
be addressed in future chapters. This is also the time
the design team will start to help the clients make selections about key pieces of furniture, lighting fixtures,
and equipment.
Initial Working Drawings
With the preliminary drawings approved, a drafter can
begin to lay out the working drawings. The procedure
will vary with each office, but generally each of the
14
FIGURE 111 The preliminary floor plan shows the owner’s changes, with furniture added.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
drawings required for the project will be started. These
will include the foundation, site, roof, electrical, cabinet,
and framing plans. At this stage the drafter must rely on
past experience for drawing the size of beams and other
structural members. Beams and other structural material will be located, but exact sizes are not determined
until the entire project has been laid out.
to get a building permit. On a complicated plan, a
wall-framing plan, a roof-framing plan, a grading plan,
and construction details may be required. Some lending institutions may require interior elevations, cabinet
drawings, and finish specifications.
The skills of the drafter will determine his or her
participation in preparing the working drawings. As
an entry-level drafter, you will often be given the job
of making corrections on existing drawings or drawing, for example, site plans or cabinets. As you gain
skill you will be given more drawing responsibility.
With increased ability, you will start to share in the
design responsibilities.
Final Design Considerations
Once the drawings have been laid out, the designer will
generally meet with the client several times again to get
information on flooring, electrical needs, cabinets, and
other finish materials. This conference will result in a
set of marked drawings that the drafter will use to complete the working drawings.
Working Drawings. The drawings that will be provided vary for each residence and within each office.
Figure 1-12 through Figure 1-17 show what are typically considered the architectural drawings. These are
drawings that show finishing materials. Figure 1-18
through Figure 1-20 show the electrical drawings.
Figure 1-21 through Figure 1-24 show what are
Completion of Working Drawings
The complexity of the residence will determine which
drawings are required. Most building departments
require a site plan, a floor plan, a foundation plan, elevations, and one cross section as the minimum drawing
1200 GAL
SEPTIC TANK
10' MIN FROM
FND.
4" CONC FLATWORK
W/ BROOM FINISH
PROPOSED
S.F.R.
730.00'
EAM
6- 120' DRAIN
LINES @10'O.C.
180'-0"+/WELL- 100' MIN.
FROM SEPTIC TANK
36'-0" DIA. MIN.
TURNAROUND
60" MIN. RADIUS
TYPICAL
W
N 30˚ 00;
BRICK PAVERS LAID
IN HERRINGBONE PATTERN
24' WIDE X 22' DEEP MIN.
PARKING
12'-0" MIN
GRAVEL
DRIVE
250'-0"+/-
N 30˚ 00' W
730.00'
STR
/'-0"+
175 MIN. )
0'
( 10
CL
OF
17
580.00'
CL
GRIGGS RD.
LEGAL:
TAX LOT 2800, LOT 5
GORDON GLEN HOMES
3E SECTION 24, T2E
EAGLE CREEK, MO
FIGURE 112 A site plan is used to show how the structure relates to the site. When the site
is relatively flat, grading information is placed on this drawing.
18
Architectural Drafting and Design
SANITARY
MANHOLE
A PROPOSED RESIDENCE FOR:
MICHAEL & TEREASA JACOBS
11130 S.E. DAVID ALAN COURT
CLACKAMAS, OR 97015
7" E
5 '5
1˚1
ACK
S4
ETB
DS
R
A
E Y
SID
10'
'
19'-
.16
220
0"
20' FRONT
YARD SETBACK
15' PUBLIC
SANITARY SEWER
EASEMENT
S
5'
97.3
LINE OF
DECK ABOVE
8'-0" RETAINING
WALL
25'-0"
32'-0"
R=3
24" MAX. DEC.
RETAINING WALL
FACE OF
CURB
DAVI
'
22
52
N
D ALA
7.
.0 0 '
18
4" CONC. DRIVEWAY
OVER GRAVEL FILL
"W
49
L=
3'
COUR
˚3
T
43
24" MAX. DEC.
RETAINING WALL
48" HIGH MAX.
RETAINING
WALL
10' SIDE YARD SETBACK
264.62'
S21˚16' 25" E
NO
RTH
24" AND 48" HIGH RETAINING WALLS
TO BE INTERLOCKING DEC. BLOCK
LEGAL:
LOT 18 OF HIGHPOINTE
IN THE N.E. 1/4 OF SEC. 34, T1S, R2E W.M.
HAPPY VALLEY, CLACKAMAS COUNTY OREGON
FIGURE 113 If grading is extensive, the site plan is separated from the grading plan. By careful use of layers, this site plan was used
as a base for the grading plan in Figure 1-14.
A PROPOSED RESIDENCE FOR:
SANITARY
MANHOLE
165
MICHAEL & TEREASA JACOBS
170
175 E
"
7
5' 5
1˚1
ACK
S4
180
ETB
DS
R
A
E Y
SID
10'
11130 S.E. DAVID ALAN COURT
CLACKAMAS, OR 97015
15' PUBLIC
SANITARY SEWER
EASEMENT
19'-
185 '
190 20.16
2
195
0"
43
'
7.35
32'-0"
165
10' SIDE YARD SETBACK
264.62'
205
200
195
TH
GRADING PLAN
1"
190
10'-0"
NOR
COUR
L=9
2.00'
'
R = 32
ENTRY DECK
F.F. 194.85'
24" MAX. DEC.
GARAGE RETAINING WALL
FIN. FL.
195.00
48" HIGH MAX.
RETAINING
WALL
52
DAV
7.
RB
FACE OF CU
18
N
ID ALA
LINE OF
DECK ABOVE
"W
25'-0"
49
4" CONC. DRIVEWAY
OVER GRAVEL FILL
3'
24" MAX. DEC.
RETAINING WALL
ENTRY FIN. FL
195.00'
8'-0" RETAINING
WALL
LOWER FIN. FL
184.00'
˚3
T
S
200
S21˚16' 25" E
185
180
175
170
LEGAL:
LOT 18 OF HIGHPOINTE
IN THE N.E. 1/4 OF SEC. 34, T1S, R2E W.M.
HAPPY VALLEY, CLACKAMAS COUNTY OREGON
24" AND 48" HIGH RETAINING WALLS
TO BE INTERLOCKING DEC. BLOCK
FIGURE 114 A grading plan is used to define new and existing grades, and the cut and fill banks that will be recreated as the soil is
relocated. On this drawing, existing soil contours are shown with dashed lines and new grade contours are represented with solid lines.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
19
300# COMPOSITION SHINGLES OVER 15# FELT
LINE OF ROOF BEYOND
2x6 FASCIA
1x3 R.S.
CORN. TRIM
HORIZ. CONC.
SIDING W/ 6"
EXPOSURE OVER
1/2" CDX PLYWOOD & TYVEK
4" CONC.
FLATWORK
6x6 POST
4" CONC. FLATWORK
5
REAR ELEVATION
10'-0"
NOTE:
EXTEND CHIMNEY FLUE A MIN.
OF 2'-0" ABOVE ANY POINT ON
ROOF WITHIN 10'-0" HORIZ.
14
48"x48" SKYLIGHT
24" MIN.
12
LINE OF ROOF BEYOND
2x6 FASCIA
BRICK VENEER OVER
1" AIR SPACE & TYVEK
W/METAL TIES @ 24" O.C.
EA. STUD 4x3x3/16" METAL
LINTEL OVER GARAGE DOOR.
SEE OWNER FOR BRICK DESIGN
FIN. FLOOR
1x3 R.S.
CORN. TRIM
LEFT ELEVATION
LINE OF COLUMN BEYOND
LINE OF PLANTER BEYOND
14
48"x48" SKYLIGHT
300# COMPOSITION SHINGLES OVER 15# FELT
5
12
8'-0"
FIN. FLR.-FIN. CEIL.
12'-0"
FIN. FLR. - FIN. CEIL.
9'-0"
FIN. FLR./FIN. CEIL.
2x6 FASCIA
3'-0"
BRICK VENEER OVER 1" AIR
6" HORIZ. CEDAR
SPACE & TYVEK W/METAL TIES
@ 24" O.C. EA. STUD 4x3x3/16" METAL
LINTEL OVER GARAGE DOOR. SEE
OWNER FOR BRICK DESIGN
FRONT ELEVATION
14
5
12
10'-0"
24" MIN.
1x3 CORN. TRIM
NOTE:
EXTEND CHIMNEY FLUE A MIN.
OF 2'-0" ABOVE ANY POINT ON
ROOF WITHIN 10'-0" HORIZ.
HORIZ. CONC. SIDING
W/ 6" EXPOSURE
OVER 1/2" CDX PLYWOOD & TYVEK
RIGHT ELEVATION
14
FIGURE 115 Once the owners have approved the preliminary designs, the exterior elevations can be completed. The
elevations will provide a view of each side of the structure and show and specify all exterior materials to be used.
typically called the structural drawings. Many architectural firms number each page based on the type of
drawing on that page. Pages are represented by:
A—Architectural
S—Structural
M—Mechanical
E—Electrical
P—Plumbing
Figure 1-12 shows the site plan that was required
for the residence in Figure 1-8. Typically the site plan
is completed by a junior drafter from a sketch provided
by the senior drafter or designer. A grading plan is not
required for every residence. Because this home is to be
built on a fairly level site, the elevations are indicated at
each corner of the structure. Figure 1-13 shows a site
plan for a hillside home. Because of the large amount
of soil to be excavated for the lower floor, the grading
20
TYPICAL DOWNSPOUT
A
2x8 RAFT.
@ 24" O.C.
A
A
B
12' PLATE
1. ALL HIPS, RIDGES & VALLEYS TO
BE 2x10 UNLESS NOTED.
2. ALL RAFTERS TO BE 2x8 DFL #2
@ 24" O.C. UNLESS NOTED.
48"x48"
SKYLIGHT
12" - 16'-2"
16" - 14'-0"
24" - 11'-5"
2x10 @
12" - 19'-8"
16" - 17-0"
24" - 13'-11"
8' PLATE
HIP SCHEDULE
A
B
8' PLATE
2x8 @
B
1. USE 1/2" 'CCX' PLY @ ALL EXPOSED
EAVES.
2. ROOF VENTS MUST HAVE AN AREA
EQUAL TO 1/150 OF THE ATTIC AREA.
3. SKYLIGHTS TO BE DOUBLE DOMED
PLASTIC BY VELEX OR EQUAL.
2x8 RAFT.
@ 16" O.C.
2x8 RAFT.
@ 16" O.C.
A
4. ALL ROOF PITCHES ARE 5/12
UNLESS NOTED.
5. 300# COMPOSITION SHINGLES
OVER 15# FELT.
FIGURE 116 The roof plan shows the shape of the roof structure as well as vents and drains.
B
A
2x12
B
2-2x12
C
5 1/8" x 10 1/2" GLULAM
D
2-2x10
E
3 1/8" x 12" GLULAM
F
5 1/8 x 13 1/2 GLULAM
G
3 1/2" x 11 7/8" MICROLLAM
Architectural Drafting and Design
12" - 12'-9"
16" - 11'-1"
24" - 9'-1"
TYP.
2'-6"
8' PLATE
2'-6" TYP.
12' PLATE
MAX. RAFT. SPAN
2x6 @
E
PURLIN SEE
FRAMING PLAN
D
B
B
2x8 RAFT.
@ 16" O.C.
2x10 RAFT.
@ 16" O.C.
12' PLATE
ROOF FRAMING NOTES:
CRICKET
D
2x8 RAFT.
@ 16" O.C.
2x8 RAFT.
@ 24" O.C.
B
PURLIN SEE
FRAMING PLAN
N
CRICKET
2x8 RAFT.
@ 16" O.C.
D
48"x48"
SKYLIGHT
2x8 RAFT.
@ 24" O.C.
B
2x8 RAFT.
@ 24" O.C.
8' PLATE
SEE SECTION
2x8 RAFT.
@ 24" O.C.
PURLIN SEE
FRAMING PLAN
12" ~SCREENED
RIDGE VENTS
B
A
B
2x8 RAFT.
@ 24" O.C.
E
2x8 RAFT.
@ 16" O.C.
CHIMNEY W/
26 ga FLASH/
COUNTER FLASH
2x8 RAFT.
@ 24" O.C.
2x8 RAFT.
@ 16" O.C.
2x8 RAFT.
@ 16" O.C.
A
CRICKET
PURLIN SEE
FRAMING PLAN
PURLIN SEE
FRAMING PLAN
CRICKET
E
2x8 PURLIN
SEE FRAMING PLAN
48"x48"
SKYLITE
8' PLATE
2x8 RAFT.
@ 16" O.C.
D
2x10 RAFT.
@ 12" O.C.
2x8 RAFT.
@ 24" O.C.
9' PLATE
2x8 RAFT.
@ 16" O.C.
12' PLATE
8' PLATE
12' PLATE
8' PLATE
PLATE HEIGHT REMAINING
LEVEL. FLOOR HEIGHT
CHANGES. SEE SECTION
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
21
BUILT-INS
8
13'-6" CEILING
B
L
6
3'-6" X 6'-0" C.T.
SUNKEN TUB
9
S&P
MASONRY FIREPLACE
W/ 18" FLUSH HEARTH
G
D
C
36" HIGH
PLANTER
8" MAX.
STEP
UP 2 RISERS
D
SCREENED
CLOSABLE VENT
WITHIN 24"
BUILT-INS
S&P
4'-0"X4'-0"
SKYLIGHT
36" HIGH
PLANTER
8" MAX.
ARCH
4'-0" X 4'-0"
SKYLIGHT
2'-6" CASE
OPENING
22" X 30" CRAWL
SPACE ACCESS
4'-0"X4'-0"
SKYLIGHT
ARCH
K
36" F.G.
SHW.
SHOWER
FULL WALL
ARCH
N
N
N
F
P
CLS
J
N
N
F
3'-6" X 7'-0"
SHOWER
N
S&P
P
60" F.G.
TUB & S.
2'-6" CASE
OPENING
F
FOLDING COUNTER
W/ SHELVES BELOW
SELF VENT
M
N
10 11
E
ARCH
S&P
A
22"X30" CRAWL
SPACE ACCESS
5/8" TYPE 'X' GYP.
BD. FLOOR AND
CEILING
6
3
4
5
BUILT-INS
1
R
INSULATE W.H. TO R-11
& PLACE ON 18" HIGH
PLATFORM
2
S
14
DESIGN BASED ON 1996 OREGON
ENERGY CODE - PATH I.
13
FIGURE 117A The preliminary floor plan is used to form the base of the finished floor plan. Text to describe all interior materials
must be provided.
DOOR SCHEDULE
SYM.
WINDOW SCHEDULE
A
3'-6" X 8'-0"
B
12'-0" X 8'-0"
C
8'-0" X 6'-8"
D
6'-0" X 6'-8"
TYPE
S.C.,R.P., W/ 24" SIDELIGHT
W/ SQ. TRANSOM ABOVE
SL. GLASS W/ 12'-0" X 3'-0"
SQ. TRANSOM ABOVE
SL. FRENCH DRS. W/ 12"
SQ. TRANSOM ABOVE
SL. GLASS DRS. W/6'-0" x
3'-0" SQ. TRANSOM ABOVE
E
3'-0" X 6'-8"
SELF CLOSING, M.I.
1
F
PR 2'-6" X 6'-8"
HOLLOW CORE
2
G
6'-0" X 6'-8"
SL. MIRROR
1
H
6'-0" X 6'-8"
BIFOLD
1
J
4'-0" X 6'-8"
BIFOLD
1
K
PR 2'-0" X 6'-8"
HOLLOW CORE
1
L
2'-8" X 6'-8"
S.C., M.I.
1
M
2'-8" X 6'-8"
HOLLOW CORE
1
N
2'-6" X 6'-8"
HOLLOW CORE
7
P
2'-4" X 6'-8"
HOLLOW CORE
3
Q
16'-0" X 8'-0"
OVERHEAD, GARAGE
1
9'-0" X 8'-0"
OVERHEAD, GARAGE
1
R
SIZE
QUAN.
DOOR NOTES:
1. FRONT DOOR TO BE RATED AT 0.54 OR LESS; VERIFY
DOOR STYLE WITH OWNER.
2. EXTERIOR DOORS IN HEATED WALLS TO BE U 0.20
OR LESS.
OR LESS.
4. ALL GLASS WITHIN 18" OF DOORS TO BE TEMPERED.
1
SYM.
SIZE
GENERAL NOTES:
TYPE
QUAN.
1. STRUCTURAL DESIGNS ARE BASED ON 2003 I.R.C
AND 1996 OREGON ENERGY CODE PATH 1.
2. ALL PENETRATIONS IN TOP OR BOTTOM PLATES
FOR PLUMBING OR ELECTRICAL RUNS TO BE
SEALED. SEE ELECTRICAL PLANS FOR ADDITIONAL
SPECIFICATIONS.
1
5'-6" X 7-'6"
ARCHED TOP
1
1
2
5'-6" X 1-0"
AWNING
1
1
3
2'-6" X 5'-0"
PICTURE
2
1
4
2'-6" X 1'-0"
AWNING
2
3. PROVIDE 1/2" WATERPROOF GYP. BD. AROUND ALL
TUBS, SHOWERS, AND SPAS.
5
2'-6" X 2'-6"
ARCHED TOP
6
1'-8" X 4'-6"
ARCHED TOP
2
1
4. VENT DRYER AND ALL FANS TO OUTSIDE AIR THRU
DAMPERED VENTS.
7
6'-0" X 4'-6"
HOR. SLIDING
1
8
5'-0" X 4'-0"
HOR. SLIDING
1
9
6'-0" X 4'-0"
HOR. SLIDING
1
10
1'-8" X 4'-6"
CASEMENT
11
3'-6" X 4'-6"
PICTURE
2
1
12
4'-0" X 3'-0"
PICTURE
1
ARCHED TOP
1
13 3'-6" X 4'-6"
WINDOW NOTES:
1. ALL WINDOWS TO BE VINYL FRAME, MILGARD
OR BETTER.
2. ALL WINDOWS TO BE U 0.40 MIN.
3. ALL BEDROOM WINDOWS TO BE WITHIN 44" OF
FIN. FLOOR.
4. GLASS WITHIN 18" OF DOORS TO BE TEMPERED.
5. ALL WINDOW HDRS. FOR 8' & 9' CEIL. HEIGHTS
TO BE SET AT 6'-8", ALL HDRS FOR 12' CEIL. TO
BE SET AT 10'-8", UNLESS OTHERWISE NOTED.
6. VERIFY HEIGHT OF WINDOW #7 WITH TUB HEIGHT.
FIGURE 117B Notes and schedules are typically displayed near the floor plan.
5. INSULATE WATER HEATER TO R-11. PROVIDE 18" HIGH
PLATFORM FOR GAS APPLIANCES.
6. PROVIDE 1/4" COLD WATER LINE TO REFRIGERATOR.
7. BRICK VENEER TO BE PLACED OVER 1" AIR SPACE,
AND TYVEK W/ METAL TIES @ 24" O.C. EA. STUD.
22
SS
4
4
FLUORESCENT LIGHTS
UP IN SOFFIT.
4
WP
(2) FLOOR OUTLETS
VERIFY LOCATION
W/ OWNER
4
4
TV
SS S
33
P
P
TO LIGHTING
IN SOFFITS
GFI
SS
S.D.
S S
3 3
SS
J
S
SSSS
GFI
GFI
GD
S3
S3
SS
TR
J
SD
3
S
S
L
S
3
WP
F
S
S
TV
GFI
F
S
S.D.
SS
TR
3
SSS
WP
P
P
120"
WP
P
S
SS S
3 33
TR
FLUORESCENT
LIGHTS IN
SOFFIT.
WP 72"
SUPPLY 220 CIRCUIT TO A.C.
S
S3
SSSS3
P
S3S3
CH.
S3
S
S
GFI
42"
S3S3S3
SS
S.D.
F
S
S
S.D.
S 3
S3S3S3
F
L
H
SD
SD
SSS
P
GFI
GFI
SD
S3
TR.
S
S
TV
WP
WP
120"
4
S3
WP
4
SS
TV
AIR COND.
S
ALL OUTLETS IN KITCHEN, LAUNDRY,
WP BATHROOM & OUTDOOR TO BE GFI.
CIR
SWITCH TURNS ON
ALL W.P. OUTLETS
MOUNTED UNDER EAVES
D
50 AMP.
ELECTRICAL PLAN
14
D
W.P.
W.P
72"
FIGURE 118A The electrical plan shows the locations for lights, plugs, switches, and other electrical fixtures and specifications. Using the floor plan as
the base drawing, the electrical drawing can be completed by adding the electrical information on new layers.
Architectural Drafting and Design
LIGHTS ON
GATE
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
23
ELECTRICAL LEGEND
ELECTRICAL NOTES:
1. ALL GARAGE AND EXTERIOR PLUGS & LIGHT FIXTURES TO BE ON GFCI CIRCUIT.
2. ALL KITCHEN PLUGS AND LIGHT FIXTURES TO BE ON GFCI CIRCUIT.
3. PROVIDE A SEPARATE CIRCUIT FOR MICROWAVE OVEN.
4. PROVIDE A SEPARATE CIRCUIT FOR PERSONAL COMPUTER. VERIFY LOCATION
WITH OWNER.
5. VERIFY ALL ELECTRICAL LOCATIONS W/ OWNER.
6. EXTERIOR SPOTLIGHTS TO BE ON PHOTOELECTRIC CELL W/ TIMER.
7. ALL RECESSED LIGHTS IN EXT. CEIL. TO BE INSULATION COVER RATED.
8. ELECTRICAL OUTLET PLATE GASKETS SHALL BE INSTALLED ON RECEPTACLE,
SWITCH, AND ANY OTHER BOXES IN EXTERIOR WALL.
9. PROVIDE THERMOSTATICALLY CONTROLLED FAN IN ATTIC W/ MANUAL
OVERRIDE (VERIFY LOCATION W/ OWNER).
CEILING-MOUNTED LIGHT
FIXTURE
CAN CEILING LIGHT FIXTURE
110 CONVENIENCE OUTLET
L
GFI 110 C.O. GROUND FAULT
INTERRUPTER
WP
110 WATERPROOF
WALL-MOUNTED LIGHT
110 HALF HOT
J
JUNCTION BOX
RECESSED LIGHT FIXTURE
P.C
220 OUTLET
10. ALL FANS TO VENT TO OUTSIDE AIR. ALL FAN DUCTS TO HAVE
AUTOMATIC DAMPERS.
11. HOT WATER TANKS TO BE INSULATED TO R-11 MINIMUM.
12. INSULATE ALL HOT WATER LINES TO R-4 MINIMUM. PROVIDE AN ALTERNATE
BID TO INSULATE ALL PIPES FOR NOISE CONTROL.
S
SINGLE POLE SWITCH
S3
THREE-WAY SWITCH
L H
F
LIGHT, HEATER, & FAN
S.D. SMOKE DETECTOR
13. PROVIDE 6 SQ. FT. OF VENT FOR COMBUSTION AIR TO OUTSIDE AIR FOR
FIREPLACE CONNECTED DIRECTLY TO FIREBOX. PROVIDE FULLY CLOSEABLE
AIR INLET.
14. HEATING TO BE ELECTRIC HEAT PUMP. PROVIDE BID FOR SINGLE UNIT NEAR
GARAGE OR FOR A UNIT EACH FLOOR (IN ATTIC).
V
VACUUM
LIGHT ON PULL CHORD
SPOTLIGHTS
48" SURFACE-MOUNTED
FLUORESCENT LIGHT FIXTURE
S
STEREO SPEAKER
P
PHONE OUTLET
TV
CABLE TV OUTLET
15. INSULATE ALL HEATING DUCTS IN UNHEATED AREAS TO R-11. ALL HVAC DUCTS
TO BE SEALED AT JOINTS AND CORNERS.
FIGURE 118B Notes and legends are placed with the electrical plan to explain fixtures.
plan was provided (see Figure 1-14). The junior drafter
may draw the base drawing showing the structure and
site plan and the designer or senior drafter will usually
complete the grading information. Typically the owner
is responsible for hiring a surveyor, who will provide
the topography and site map, although the designer
may coordinate the work between the two offices.
Section 3 will provide insight into how these two
drawings are developed.
Using the preliminary drawing that was presented in
Figure 1-10, the working elevations can be completed.
Depending on the complexity of the structure, they
may be completed by either the junior or the senior
drafter. Figure 1-15 shows the working elevations
for this structure. Section 7 will provide information
needed to complete working elevations, and Section 11
will introduce presentation elevations.
Figure 1-16 and Figure 1-17 show the completed
plan views of this structure. Figure 1-16 shows the
view from flying over the structure. The roof plan is
often completed by the junior drafter using sketches
provided by the senior drafter. Section 6 will provide
information on roof plans. The floor plan, represented
in Figure 1-17A, is usually completed by the senior
drafter. These drawings provide information related
to the room arrangements and interior finishes. Junior
drafters also work on the plan views by making corrections or adding notes, which are typically placed on
a marked-up set of plans provided by the designer or
senior drafter. Section 4 will provide information for
completing floor plans.
Figure 1-18 shows the electrical plan. Depending
on the complexity of the residence, electrical information may be placed directly on the floor plan. A junior
drafter typically completes the electrical drawings
by working from marked-up prints provided by the
designer. Chapter 19 will provide information for completing the electrical plans.
Figure 1-19 through Figure 1-21 represent the framing plans and notes associated with these drawings.
The notes shown with Figure 1-19 are standard notes
that specify the nailing for all framing connections.
Depending on the complexity of the structure, framing
information may be placed on the floor plan. Because
of the information to be shown regarding seismic and
wind problems, separate framing plans have been
provided. Typically these drawings would be completed by the designer and the senior drafters. Notice in
Figure 1-21B that notes have been provided to specify
the minimum code standards used to design the residence. Section 6 and Section 8 will provide information
needed to complete the framing plans.
Figure 1-22 and Figure 1-23 contain the section
views required to show the vertical relationships of
materials specified on the framing plans. Office practice
varies greatly on what drawings will be provided, the
scale to be used, and the detail that will be shown in
the sections. Section 10 will provide information for
drawing sections. Sections are typically drawn by the
designer and the senior drafter and completed by the
junior drafters. Section 10 will provide information for
creating building sections and details.
24
Architectural Drafting and Design
FASTENER SCHEDULE
CAULKING NOTES:
CAULKING REQUIREMENTS BASED ON 1992 OREGON
RESIDENTIAL ENERGY CODE
1. SEAL THE EXTERIOR SHEATHING @ CORNERS, JOINTS,
DOOR AND WINDOW, AND FOUNDATION SILLS W/
SILICONE CAULKING.
2. CAULK THE FOLLOWING OPENINGS W/ EXPANDED FOAM
OR BACKER RODS. POLYURETHANE, ELASTOMERIC
COPOLYMER, SILCONIZED ACRYLIC LAYTEX CAULKS MAY
ALSO BE USED WHERE APPROPRIATE.
ANY SPACE BETWEEN WINDOW AND DOOR FRAMES
BETWEEN ALL EXTERIOR WALL SOLE PLATES AND PLY
SHEATHING
ON TOP OF RIM JOIST PRIOR TO PLYWOOD FLOOR
APPLICATION
WALL SHEATHING TO TOP PLATE
JOINTS BETWEEN WALL AND FOUNDATION
JOINTS BETWEEN WALL AND ROOF
JOINTS BETWEEN WALL PANELS
AROUND OPENINGS FOR DUCTS, PLUMBING, ELECTRICAL,
TELEPHONE
AND GAS LINES IN CEILINGS, WALLS AND FLOORS. ALL
VOIDS AROUND
PIPING RUNNING THROUGH FRAMING OR SHEATHING TO
BE PACKED
ALTERNATE ATTACHMENTS
TABLE NO R 402.3A (1)
NOMINAL
THICKNESS
5/16"
3/8"
15/32"
& 1/2"
19/32"
& 5/8"
23/32"
& 3/4"
1"
DESCRIPTION (1,2)
OF
FASTENERS &
LENGTH
.097-.009 NAIL 1 1/2"
STAPLE 15 GA. 1 3/8"
STAPLE 15 GA. 1 3/8"
.097-.099 NAIL 1 1/2"
STAPLE 15 GA. 1 1/2"
.097-.099 NAIL 1 5/8
.113 NAIL 1 7/8"
STAPLE
T
15 & 16 GA. 1 5/8"
.097-.099 NAIL 1 3/4"
STAPLE 14 GA. 1 3/4"
STAPLE 15 GA. 1 3/4"
.097-.099 NAIL 1 7/8"
STAPLE 14 GA. 2"
.113 NAIL 2 1/4"
STAPLE 15 GA. 2"
.097-.099 NAIL 2 1/8"
SPACING OF
FASTENERS
INTERMEDIATE
EDGES SUPPORTS
6"
6
4
6
3
12"
12
10
12"
6"
6
3"
6
5
3
6
4"
12"
6"
12
10
6
10"
8"
3"
6"
FLOOR UNDERLAYMENT:
PLYWOOD, HARDBOARD, PARTICLEBOARD
|" & 5/16"
3/8"
1/2"
.097-.099 NAIL 1 1/2"
STAPLE 15 &
16 GA. 1 1/4"
.080 NAIL 1 1/4"
STAPLE 18 GA. 3/16
CROWN 7/8"
STAPLE 15 & 16 GA
1 3/8"
.097-.099 NAIL
1 1/2"
.080 NAIL 1 3/8"
.113 NAIL 1 7/8"
STAPLE 15 & 16
GA. 1 1/2"
.097-.099 NAIL
1 3/4"
6"
12"
5"
10"
DESCRIPTION OF
BUILDING MATERIAL
NUMBER & TYPE
OF FASTENERS
(1,2,3,5,)
1. JOIST TO SILL OR GIRDER, TOE
NAIL
2. BRIDGING TO JOIST, TOENAIL EA.
END
3. 1 x 6 (25 X 150) SUBFLOOR OR
LESS TO EACH JOIST, FACE NAIL
5"
10"
6"
12"
5"
6"
1. NAIL IS A GENERAL DESCRIPTION AND MAY BE T-HEAD,
MODIFIED ROUND HEAD, OR ROUND HEAD.
2. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF
7/16" O.D. EXCEPT AS NOTED.
3. NAILS OR STAPLES SHALL BE SPACED AT NOT MORE
THAN 6" O.C. AT ALL SUPPORTS WHERE SPANS ARE 48" OR
GREATER. NAILS OR STAPLES SHALL BE SPACED AT NOT
MORE THAN 10" O.C. AT INTERMEDIATE SUPPORTS FOR
FLOORS.
6d 6
5/8" (16 mm)
8d 6
7
1/2" (13 mm)
No. 16 ga.9
2-8d
25/32" (20 mm)
4. WIDER THAN 1 x 6 (25 x 150)
SUBFLOOR TO EACH JOIST, FACE 3-8d
NAIL
5. 2" (50) SUBFLOOR TO JOIST OR
GIRDER BLIND AND FACE NAIL
6. SOLE PLATE TO JOIST OR
BLOCKING FACE NAIL
SOLE PLATE TO JOIST OR
BLOCKING AT BRACED WALL
PANELS
7. TOP OR SOLE PLATE TO STUD,
END NAIL
No. 11 ga.8
6d 4
No. 16 ga.9
2-16d
16d @ 16" (406mm) O.C.
No. 11 ga.
6d 4
2-8d
29. INTERIOR PANELING
3- 16d PER
16" (406mm) O.C.
1/4" (6.4 mm)
4d 10
2-16d
3/8" (9.5 mm)
4d 11
8. STUD TO SOLE PLATE, TOE NAIL
4-8d, TOENAIL OR
2-16d END NAIL
9. DOUBLE STUDS, FACE NAIL
16d @ 24" (610mm) O.C.
10. DOUBLE TOP PLATE, FACE NAIL
16d @ 16" (406mm) O.C.
DOUBLE TOP PLATE, LAP SPLICE 8-16d
11. BLOCKING BTWN. JOIST OR
RAFTERS TO TOP PLATE, TOENAIL 3- 8d
12. RIM JOIST TO TOP PLATE, TOENAIL 8d @ 6" (152mm) O.C.
13. TOP PLATES, TAPS & INTERSEC2-16d
TIONS, FACE NAIL
14. CONTINUED HEADER, TWO PIECES 16d @ 16" (406mm) O.C.
ALONG EACH EDGE
1. - COMMON OR BOX NAILS MAY BE USED EXCEPT
WHERE OTHERWISE STATED.
2. - NAILS SPACED @ 6" (152 mm) ON CENTER @ EDGES,
12" INTERMEDIATE SUPPORTS EXCEPT 6" (152 mm) AT
ALL SUPPORTS WHERE SPANS ARE 48" 1220 mm OR
MORE. FOR NAILING OF WOOD STRUCTURAL PANEL
AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS,
REFER TO SECTION 2314.3. NAIL FOR WALL SHEATHING
MAY BE COMMON, BOX OR CASING.
3. - COMMON OR DEFORMED SHANK.
15. CEILING JOIST TO PLATE, TOE NAIL 3-8d
4. - COMMON.
16. CONTINUOUS HEADER TO STUD,
TOE NAIL
17. CEILING JOIST, LAPS OVER
PARTITIONS, FACE NAIL
18. CEILING JOIST TO PARALLEL
RAFTERS, FACE NAIL
19. RAFTERS TO PLATE, TOE NAIL
20. 1" (25mm) BRACE TO EA. STUD &
PLATE FACE NAIL
21. 1 x 8 (25 x 203mm) SHEATHING OR
LESS TO EACH BEARING, FACE
NAIL
22. WIDER THAN 1 x 8 (25 X 203mm)
SHEATHING TO EACH BEARING,
FACE NAIL
23. BUILT-UP CORNER STUDS
24. BUILT-UP GIRDER AND BEAMS
4-8d
5. - DEFORMED SHANK.
3-16d
6. - CORROSION-RESISTANT SIDING OR CASING NAILS.
3-16d
3-8d
2-8d
2-8D
3-8d
8. - CORROSION-RESISTANT ROOFING NAILS W/ 7/16" ~
(11 mm) HEAD & 1 1/2" (38 mm) LENGTH FOR 1/2" (13 mm)
SHEATHING AND 1 3/4" (44 mm) LENGTH (FOR 25/32" (20
mm) SHEATHING CONFORMING TO THE REQUIREMENTS
OF SECTION 2325.1.
9. - CORROSION-RESISTANT STAPLES WITH NOMINAL
7/16" (11 mm) CROWN AND 1 1/8" (29 mm) LENGTH FOR
20d @ 32" (813 mm) O.C. 1/2" (13 mm) SHEATHING AND 1 1/2" (38 mm) LENGTH
FOR 25/32" ( 20 mm) SHEATHING CONFORMING TO THE
@ TOP/BOTTOM &
REQUIREMENTS OF SECTION 2325.1.
STAGGER 2-20d @
ENDS & @ EACH SPLICE.
2-16d AT EACH
BEARING
26. WOOD STRUCTURAL PANELS AND 2
PARTICLEBOARD:
SUBFLOOR, ROOF AND WALL SHEATHING
( TO FRAMING) 1" = 25.4mm)
1/2" OR LESS
6d 3
19/32 - 3/4"
8d OR 6d 5
7/8 - 1"
8d 3
1 1/8 - 1 1/4"
10d 4 OR 8d 5
COMBINATION SUBFLOOR—UNDERLAYMENT (TO FRAMING) 1" = 25.4 mm)
3/4" AND LESS
7. - FASTENERS SPACED 3" (76 mm) O.C. AT EXTERIOR
EDGES AND 6" (152 mm) O.C. AT INTERMEDIATE
SUPPORTS.
16d @ 24" (610 mm) O.C.
25. 2" PLANKS
12"
1/2" (13 mm)
28. FIBERBOARD SHEATHING:
3-8d
6"3
""
6"
27. PANEL SIDING (TO FRAMING):
10. - PANEL SUPPORTS @ 16" (406 mm) O.C. 20" (508
mm) IF STRENGTH AXIS IN LONG DIRECTION OF THE
PANEL, UNLESS OTHERWISE MARKED CASING OR
FINISH NAILS SPACED 6" (152 mm) ON PANEL EDGES,
12" (305 mm) AT INTERMEDIATE SUPPORTS.
11. - PANEL SUPPORTS @ 24" (610 mm). CASING OR
FINISH NAILS SPACED 6" (152 mm) ON PANEL EDGES,
12" (305 mm) AT INTERMEDIATE SUPPORTS.
INSULATION NOTES:
INSULATION BASED ON PATH # 1 OF 1992
OREGON RESIDENTIAL ENERGY CODE.
8d 5
7/8" - 1"
8d 5
1 1/8 - 1 1/4"
10d 4 OR 8d 5
FIGURE 119 Many offices use one or more sheets to include all standard framing notes and building specifications.
6x12 HDR.
6x10 HDR.
4x8 HDR.
2x6 C.J. @
16" O.C.
4x6
4x6 HDR.
NOTES:
1. ALL HEADERS TO BE SUPPORTED BY 2x6
TRIMMERS AND KING STUD UNLESS OTHERWISE
NOTED.
2. STRUTS SHALL NOT BE SMALLER THAN 2x4
MEMBERS. THE UNBRACED LENGTH
OF STRUTS SHALL NOT EXCEED 8' AND THE
MINIMUM SLOPE OF THE STRUTS SHALL NOT BE
LESS THAN 45˚ FROM THE HORIZONTAL.
3. HIP, VALLEY AND RIDGE TO BE 2x10 UNLESS NOTED.
4. SEE SHEET 8A FOR SYMBOL DEFINITION.
5. EXTEND INTERIOR BEARING WALLS THROUGH TO RAFT.
USE 2x4 @ 24" O.C. MAX. @ 45˚ MAX.
4x12 STRONGBACK
W/ 2-H5 EA. END.
2x6 C.J @
16" O.C.
HDR.
4x4
2-2x4
MST 27
2x4 BRACE
45˚ MAX.
TYP.
2x6 C.J @
16" O.C.
BEARING WALL
2x6 C.J @
16" O.C.
4x8 HDR.
6x12
HDR.
SEE NOTE #7
4x4
THIS SYMBOL REPRESENTS
THE LOCATIONS OF ALL THE
2x4 ROOF SUPPORTS. BRACES
TO BE WITHIN 45˚ OF VERT.
4x4
HDR.
4x4 HDR. 4x4 HDR.
4x8 HDR.
MST 27 W/ SOLID
BLOCK @ WALL
4x4 U-26 HGR.
TYP.
4x6 HDR.
4x4 W/
PC 44
4x4 HDR.
2x6 C.J
@ 16" O.C.
2x6 C.J @
16" O.C.
2x6 C.J. @
24" O.C.
4x10 HDR.
4x4
HDR.
BEARING
WALL
5 1/8" x 13.5" GLU-LAM
5 1/8" x 13.5" GLU-LAM
4x6 HDR.
2x6 C.J.
@ 16" O.C.
W/HUC410TF
4x10 HDR.
3-2x6
2x6 C.J @
16" O.C.
4x4
HDR.
5.125"x10.5"
GLU-LAM
2x6 C.J.
@ 16" O.C.
4x10 HDR.
FLUSH
2x6 C.J.
@ 16" O.C.
2x6 C.J. @
16" O.C.
MST 27
2x10
VALLEY
6x10
STRONGBACK
4x12 HDR. 4x4 HDR.
2x6 C.J. @
16" O.C.
4x6 HDR.
FLUSH
4x8 HDR.
BEARING
WALL
ABOVE
4x8 HDR.
2x6 C.J. @
16" O.C.
4x4
HDR.
4x6 HDR.
2x6 C.J @
16" O.C.
4x4 PC44
4x6 HDR.
BEARING WALL ABOVE
1x4 LET IN
BRACE TYP.
4x12 HDR.
3-2x4
6x12 STRONGBACK
4x10 HDR.
4x10 HDR.
2x6 C.J. @
16" O.C.
2x6 C.J @
16" O.C.
4x6 HDR.
4x4 HDR.
4x14 HDR.
2-2x4
FLUSH
4x4
2x8 C.J. @
16" O.C.
6x6
CC 5|-6
5 1/8" x 10.5" GLU-LAM
2x6 C.J. @ 16" O.C.
5 1/8" x1 0.5" GLU-LAM
3 1/8" x 13.5" GLU-LAM
4x8 HDR.
4x6 HDR.
4x6 HDR.
4x6 HDR.
MST 28
W/ SOLID
BLOCK
@ WALL
4x14 HDR.
4x6 HDR.
6x12 HDR.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
6x6 W/
PC66 CAP
MST 27 SOLID
BLOCK @ WALL
MST 48 STRAP
FROM BM. TO BM.
MST 27 SOLID
BLOCK @ WALL
ECC 5|-4
4x8 HDR.
25
FIGURE 120 Because of the complicated roof structure, the material used to frame the roof is separated from the material displayed on the roof plan (Figure 1.16).
The roof plan shows the material used to frame the roof. The roof framing plan is used to display the structural materials used to transfer roof loads into the walls.
26
90'-0"
MST 27
4x6 HDR.
1
1'-0"
19'-0"
C
1'-0"
12'-4"
12
4'-4"
3'-8"
5'-4"
32'-4"
3'-2"
2'-8"
11'-8"
8'-8"
A
C
1
2'-0"
B
1
13'-0"
MST 27 SOLID
BLOCK @ WALL
R
PROVIDE 4"x3"x 5/8"
STEEL OVER EA. DOOR
& WINDOW TYPICAL.
5 1/8" x 13.5" GLU-LAM
5 1/8" x 10.5" GLU-LAM
2x6 C.J. @ 16" O.C.
MST 48 STRAP
FROM BM. TO BM.
Q
C
5 1/8" x1 0.5" GLU-LAM
6'-0"
4x8 HDR.
10 11
71'-0"
4x6 HDR.
C
1
8'-4"
MST 27 SOLID
BLOCK @ WALL
A
1
25'-8"
3'-2"
4x4 HDR. 4x4 HDR.
3'-10"
10'-0"
4x4 HDR.
4x8 HDR.
ECC 5 1/4 x 4
13
8'-0"
8'-4"
2x6 C.J @ 16" O.C.
2x6 C.J @ 16" O.C.
6x12
HDR.
9'-10"
15'-0"
3'-10"
C
1
A
1
12'-0"
N
P
9'-10"
+
B
1
17'-0"
90'-0"
FIGURE 121A In addition to showing materials needed to frame the structure, materials needed to resist wind, seismic, and other forces of nature are shown.
Architectural Drafting and Design
A
0
2'-6" 2'-6"
6x6
CC 5 1/4" x 6
2'-7"
2
2'-4"
5'-4"
E
M
5'-0"
4x10 HDR.
4x4
4x8 HDR.
4'-6"
5'-4"
2x6 C.J. @ 24" O.C.
C
1
P
4x4
HDR.
A
0
38'-8"
2-2x4
SEE NOTE #7
6'-6"
6'-6"
B
1
J
2'-6" 2'-10"
7'-2"
4x4
U-26 HGR.
TYP.
N
8'-1"
2x6 C.J @ 16" O.C.
N
2x6 C.J
@ 16" O.C.
4'-0"
3'-10"
6'-0"
8'-4"
4x4 HDR
5'-4"
4x4 HDR.
P
1'-0"
1/4"
N
4x4
HDR.
7'-8"
1'-0"
FRAMING PLAN
N
4x4
HDR.
5'-8"
33'-4"
4x4 W/
PC 44
FLUSH
4x8 HDR.
4x4 HDR.
2x6 C.J @ 16" O.C.
4'-0"
9'-6"
4x4
H
4x6 HDR.
2x6 C.J @ 16" O.C.
2'-10"
4'-6"
5'-6"
7'-6"
6'-10"
7'-3"
5
G
4x12
HDR.
3
9
3 1/8" x 13.5" GLU-LAM
7'-6"
14'-8"
12" WIDE
WALL
7'-0"
4'-0"
1x4 LET IN
BRACE TYP.
8'-10"
4x6
HDR.
4x6 HDR.
4
A
D
FULL
WALL
MST 27
9'-4"
12'-4"
B
1
A
0
4x6 HDR.
8
L
D
4x4 PC44
MST 27
W/ SOLID
BLOCK
@ WALL
4x12
STRONGBACK
2x6 C.J. @ 16" O.C. W/ 2-H5 EA. END.
B
1
4x8 HDR.
2x6 C.J. @ 16" O.C.
6
4'-0"
F
8'-4"
4'-0"
1'-0"
4x6 HDR.
3'-0"
3-2x6
0"
B
1
4'-0"
4x10 HDR.
-1
2x6 C.J. @ 16" O.C.
4'-8"
2x6 C.J. @ 16" O.C.
5'-8"
K
4'-2"
16" WIDE
WALL
2'-4"
2'-10"
8'-6"
6'-2"
5'
A
0
2'-4"
N
7'-6"
10'-10"
4x10 HDR.
FLUSH
4x6 HDR.
2x6 C.J.
@ 16" O.C.
4'-2"
N
5'-6"
16" O.C.
3'-10"
2x6 C.J. @
4'-10"
3'-8"
2'-2"
4x8 HDR.
37'-0"
7'-4"
2'-8"
F
2'-10"
7'-0"
A
A
0
4x6 HDR.
2x6 C.J @ 16" O.C.
4x12 HDR.
3'-0"
6x12 HDR.
3'-2"
7'-2"
4x6 HDR.
4x14 HDR.
FLUSH
7'-2"
16'-0"
B
6'-0"
2x6 C.J. @ 16" O.C.
2x6 C.J. @ 16" O.C.
1'-0"
5'-8"
4x10 HDR.
14'-2"
5'-8"
2x6 C.J @ 16" O.C.
4'-0"
2'-4"
12'-6"
4x4
D
8'-10"
B
A
0
2x8 C.J. @ 16" O.C.
2-2x4
3-2x4
6x12 STRONGBACK
1'-10"
72'-6"
B
1
B
1
2'-2"
8'-4"
A
0
B
1
C
4x8 HDR.
4x14 HDR.
5'-6"
17'-2"
7
4x6 HDR.
MST 28
W/ SOLID
BLOCK
@ WALL
B
4x6 HDR.
6x10 HDR.
B
1
5'-6"
1'-6"
5'-8"
6x6 W/
6x12 HDR. EPC66 CAP
7'-4"
8'-10"
7'-6"
7'-0"
6'-0"
6'-8"
7'-2"
5'-9"
11'-2"
5 1/8"x10.5" GLU-LAM
6'-1"
14'-6"
5 1/8" x 13.5" GLU-LAM
4'-3"
25'-6"
13'-8"
8'-10"
4'-0"
11'-10"
19'-10"
4'-7"
3'-10"
3'-8"
8'-10"
32'-0"
2'-4"
24'-6"
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
27
NOTES:
1. ALL FRAMING LUMBER TO BE DFL. #2 MIN.
2. FRAME ALL EXTERIOR WALLS W/ 2X6 STUDS @ 16" O.C.
ALL EXTERIOR HEADERS TO BE 4X6 DFL. #2 UNLESS NOTED.
3. ALTERNATE: FOR ALL BMS. SMALLER THAN 4X10 USE 2X6
NAILER AT THE BOTTOM OF ALL 4X HEADERS @ EXTERIOR
WALLS. BACK HEADER W/ 2" RIGID INSULATION.
4. ALL SHEAR PANELS TO BE 1/2" PLY NAILED W/ 8 d'S @ 4" O.C. @
EDGE BLOCKING AND 6 d'S @ 8" O.C. @ FIELD UNLESS NOTED.
5. ALL METAL CONNECTORS TO BE BY SIMPSON CO. OR OTHER.
6. ALL ANGLES ON INTERNAL WALLS TO BE 45˚ UNLESS
OTHERWISE SPECIFIED.
7. USE 4X6 POST W/ EPC 5 1/4 TOP CAP TO 4X6 POST & PC 46
BASE CAP UPSIDE/DOWN TO HDR OVER GARAGE/HALL DOOR.
8. 1X4 DIAG. LET IN BRACE @ 45˚ MAX. TYPICAL.
9. BLOCK ALL WALLS OVER 10'-0" HIGH AT MIDHEIGHT.
10. SEE SHEET 8A FOR SYMBOL DEFINITIONS.
SHEAR WALL SCHEDULE
MARK
A
B
C
WALL COVER
EDGE NAIL'G
15/32" C-D EXTR.
8d @ 6" O.C.
PLYWD. (1) SIDE
-U BLOCKED
-UNBLOCKE
15/32" C-D EXTR.
PLYWD. (1) SIDE - 8d @ 6" O.C.
BLOCKED EDGES
15/32" C-D EXTR.
PLYWD. (1) SIDE - 8d @ 4" O.C.
BLOCKED EDGE
FIELD NAIL'G
8d @ 12" O.C.
8d @ 12" O.C.
8d @ 12" O.C.
HOLD DOWN SCHEDULE
MARK
HOLD DOWN
0
NON-REQ'D
1
SIMPSON
PAHD42
CONN. MEMBER
DETAIL
8d @ 6" O.C.
FIGURE 121B Notes specifying minimum building standards are shown near the
framing plan.
Figure 1-24 shows what is typically the final drawing
in a set of residential plans, although the foundation
plan is one of the first drawings used at the construction site. Because of the importance of this drawing,
it is typically completed by the designer or the senior
drafter, although junior drafters may work on corrections or add notes to the drawing. Section 9 will provide
information for creating drawings to represent the foundation and floor system.
As you progress through this text, you will be
exposed to each type of working drawing. It is important to understand that a drafter would rarely draw one
complete drawing and then go on to another drawing.
Because the drawings in a set of plans are so interrelated, often one drawing is started, and then another
drawing is started so that relationships between the two
can be studied before the first drawing is completed. For
instance, floor plans may be laid out, and then a section
may be drawn to work out the relationships between
floors or any headroom problems.
When the plans are completely drawn, they must
be checked. Dimensions must be checked carefully
and cross-referenced from one plan to another. Bearing
points from beams must be followed from the roof
down through the foundation system. Perhaps one of
the hardest jobs for a new drafter is coordinating the
28
Architectural Drafting and Design
2x8 RAFT.
@ 16" O.C.
LINE OF ROOF BEYOND
3.125x12" GLULAM
3.125x12" GLULAM
300# COMP.
SHINGLES OVER
15# FELT
12" R-30 MIN. BLOWN-IN
BATH 2
BED 2
8"MIN,
6x10
GIRDER
6" BATTS.
R-25 MIN.
6x10 GIRDER
2x6 DFPT SILL W/ 1/2" Ø @ 10"
A.B. @ 6'-0" O.C. MAX. -7"
MIN. INTO CONC. ANCHOR
BOLT W/ ~2" WASHER
4x4 POST
6"
GUSSET
8"
12"
4x6 HDR.
BED 3
2x4 @ 16" O.C.
2x4 LEDGER
2x4 STUDS @ 16" O.C.
6" BATTS. R-21 MIN.
2x4 SILL, TYP.
3/8" HARDBOARD
OVERLAY
2x6 MUDSILL
1/2" SHEETROCK
12"
MIN.
C
1
2'-6"
TYP.
BATH 3
8'-0"
1x4 T&G @ ALL
EXPOSED EAVES
W/ 2x4 NAILER &
CONT. VENT
12"MIN,
2-2x4 TOP
PLATES, TYP.
(2) 2x6 TOP PLATE
LAP 48" MIN. TYP.
ALL EXT. WALLS
2x6 FASCIA
W/ GUTTER
BAFFLE
2x6 C.J.
@ 16" O.C.
SOLID BLOCK
2x4 NAILER
W/ U24 HGR.
2x8 RAFT
@ 16" O.C.
A
0
18"
MIN.
SOLID BLOCK OMIT
EA. 3RD FOR
SCREENED VENTS
12
TYP. 5
2x4 BRACE
@ 48" O.C.
45˚ MAX. TYP.
CONC. PIER SEE
FND. PLAN FOR
.006 BLACK
VAPOR BARRIER
SECTION A-A
1'-0"
3/8"
NOTES:
1. SEE FND. PLAN FOR GIRDER AND
PIER SIZES.
2. SEE SHEET 8A FOR SYMBOL DEFINITIONS.
SOLID BLOCK OMIT
EA. 3RD FOR
SCREENED VENTS
45˚ MAX.
5
12
2x8 RAFT.
@ 24" 0.C.
4x4 26 ga.
METAL FLASH
2x4 PLATE
2x4 @16" O.C.
2x4 BRACE @ 48" O.C.
2x6 C.J. @ 16" O.C.
U-26 HGR.
EA. SIDE
2x6 FASCIA
W/ GUTTER
1x4 T&G @ ALL
EXPOSED EAVES
W/ 2x4 NAILER &
CONT. VENT
4" BRICK VENEER
W/ 1" AIR SPACE
W/ METAL TIES @
24" O.C. EA. STUD
3/8"
NOTES:
8"MIN,
9'-0"
2x6 @ 16" O.C.
2-2x4 TOP >
GUSSET
2x4 STUDS
@ 16" O.C.
4x4 POST
2x4 SILL
6"
12"MIN,
2x6 T&G
DECKING
8"
16"
1" TREAD
MATERIAL
SOLID BLOCK
6" TYP.
(7 3/4" MAX.)
12"
MIN.
18"
MIN.
2X6 DFPT SILL W/ 1/2"
@ 10" A.B. @ 6'-0" O.C.
MAX. -7" MIN. INTO CONC.
ANCHOR BOLT W/ 2" WASHER
SECTION B-B
4x10 HDR.
8'-0"
LINE OF WALL
BEYOND
CONC. PIER SEE
FND. PLAN FOR
SIZE
1'-0"
1. SEE SECTION A-A FOR BALANCE OF NOTES.
FIGURE 122 Sections are used to show the vertical relationships of the structural members. A section or detail is used to represent
each major shape within the structure.
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
29
2-2x12 RIDGE
BLOCK
RIDGE VENT
2x8 RAFTER
@ 16" O.C.
2x4 BRACE
48" O.C. @ 45˚
45˚ MAX.
2x6 C.J.
@ 24" O.C.
5 1/8"x13.5"
GLU-LAM
12" MIN.
8'-0"
6"
HGR. 4"x3"x 5/8"
STEEL W/ 4"
LEG TO WALL. TYP.
7'-0"
2x6 DFPT SILL
LINE OF FIN. FLOOR
SECTION C-C
3/8"
16"
B
1
GARAGE
2x6 DF SILL
8"
5
3 1/8"x13.5"
GLU-LAM
U-26 EA. SIDE
5/8" TYPE 'X' GYP. BD.
FOR 1-HR. WALL & CEIL.
A
0
12
2x6 C.J.
@ 16" O.C.
4" CONC. SLAB OVER
4" GRAVEL-SLOPE
1/4" / 12" FOR DRAINAGE.
1'-0"
NOTES:
THICKEN SLAB
TO 8" @ EDGE
6x12 CONT.
FOOTING
1. SEE SECTION A-A FOR BALANCE OF NOTES.
2. SEE SHEET 8A FOR SYMBOL DEFINITIONS.
2x10 RAFTER
@ 12" O.C.
3.125"x12" GLU-LAM HIP
2x8 RAFTER
@ 24" O.C.
2"x12" HIP
12
5
2x8 COLLAR TIE @ 48" O.C.
2x6 NAILER
2x8 RAFTER @ 24" O.C.
2x8 PURLIN
2x4 PURLIN BRACE
@ 48" O.C. @ 45˚ MAX.
FROM VERT.
2x8 C.J.
@ 16" O.C.
SOLID BLK.
4x14 HEADER
2'-0"
2-2x4 TOP
PLATES, TYP.
LINE OF WALL
BEYOND
15'-6"
SOLID BLOCK @ MID
SPAN FOR ALL WALLS
OVER 10'-0" HIGH
2x4 NAILER
13'-6"
9'-0"
2X6 LEDGER
W/ U26 HGR.
PLANTER BEYOND
1" TREAD MATERIAL
2x8 LEDGER
W/ U210 HGR.
4x8
TYP.
4x10
1'-6"
2x12 STRINGER
@ 16" O.C.
2x KICKER
GUSSET
SECTION D-D
3/8"
.006 BLACK
VAPOR BARRIER
1'-0"
4x10
GIRDER & CONC.
PIER. SEE FOUNDATION
PLAN FOR SIZE.
NOTES:
1. SEE SECTION A-A FOR BALANCE OF NOTES.
2. SEE FND. PLAN FOR GIRDER AND PIER SIZE.
FIGURE 123 Each section is referenced to the framing plan with a viewing plane line to show where the structure is “cut” and in
which direction the viewer is looking.
30
90'-0"
1/2"X10 @
48" O.C.
1'-6"
4'-0"
4'-0"
4'-0"
32'-4"
4'-0"
4'-0"
4'-0"
4'-4"
9'-2"
1/2"X10 @
48" O.C.
18'-0"
4'-0"
1'- 2"
5'-4"
B
1
2 X 6 D.F.P.T. SILL W/
1/2"X10" A.B. @ 6'-0" O.C.
7" MIN. INTO CONC. & 12"
MAX. FROM ANY CORNER
W/ 2" WASHERS W/ 2 MIN.
PER PLATE.
18" X 6" SCREENED
CLOSABLE VENTS @
10' O.C. & 3' OF EA.
CORNER. PLACE VENTS
TO AVOID KING STUDS.
8"
BLOCK OUT
FOR DOORS
38'-8"
15'-8"
30"X12" DP.
CONC. PIER
W/ CB66
2'-7"
PROVIDE 1/2" AIR SPACE
@ ENDS & SIDE W/ 55#
FELT & 3" MIN. BEARING
A
0
1'-10"
1'-6"
TYP. @
VENEER
11'-0"
A
1
9'-10"
8'-0"
4'-0"
4'-0"
2'-0"
13'-0"
6'-6"
3 1/2"
C
1
PROVIDE 1/2" AIR SPACE @
ENDS & SIDE W/ 55# FELT
& 3" MIN. BEARING
9'-4"
6'-0"
4'-9"
4'-0"
4'-0"
4'-3"
4x10 GIRDER W/18" x 8"
C
1
4x8 GIRDERS
W/ 15" O.C.
12'-4"
16'-4"
B
1
15"x15"x12"DP.
W/ PB44
4x8 TYP.
C
1
5'-1"
4x8 BLOCK EA. SPAN W/ U46 HGR.
7'-0"
18
R
4'-6"
2'-0" 1'-8" 3'-6"
4'-0"
4'-0"
4'-0"
2'-10"
4'-0"
3'-10"
4x10 GIRDER W/18"¯ x 8" PIERS
1'-4"
4'-0"
3'-2"
12"x6"
TYP.
4" CONC. SLAB OVER 4"
GRAVEL. FILL SLOPE |"
MIN. PER FT. FOR DRAINAGE.
21"x21"x12"DP.
CONC. PIER.
A
1
6'-0"
9'-10"
25'-8"
B
1
17'-0"
1'-0"
15'-0"
U46 HGR. TYP.
4'-0"
A
0
3'-2"
19'-0"
2'-8"
4'-0"
4'-0"
8"
TYP.
90'-0"
FIGURE 124 The foundation plan shows how each of the loads will be supported. The foundation resists not only the loads caused by gravity but also the
loads from seismic forces, winds, and flooding.
Architectural Drafting and Design
1'-0"
8'-0"
OO
FL
TH
IS
4x8 GIRDER ON 4x4
2'-4"
POST (4x6 @ SPLICE)
W/ GUSSET ON 55# FELT
ON 15"¯ x 8" CONC. PIERS. TYP.
1. ASSUMED SOIL BEARING PRESSURE OF 2000 P.S.F.
2. ALL CONC. TO BEAR ON FIRM, NATURAL UNDISTURBED SOIL.
3. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS TO BE:
WALLS NOT EXPOSED TO WEATHER
2500 PSI
WALLS EXPOSED TO WEATHER
3000 PSI
PORCHES,STEPS AND GARAGE SLAB 3500 PSI
4. EXTEND FOOTINGS BELOW FROST LINE,(12" MIN. INTO NATURAL
SOIL FOR 1 STORY AND 2 STORY CONSTRUCTION). FOOTINGS
TO BE 6" THICK FOR 1 STORY, AND 7" THICK FOR 2 STORY
CONSTRUCTION. ALL FOUNDATION WALLS TO BE 8" WIDE
UNLESS STEEL IS PROVIDED WITHIN 2" BUT NOT CLOSER THAN
1" FROM THE FACE OF THE WALL AWAY FROM THE SOIL. STEEL
TO BE 2-#3'8 HORIZONTAL.
5. THE GRADE AWAY FROM THE FOUNDATION WALLS TO FALL
A MIN. OF 6" WITHIN THE FIRST 10 FEET.
6. ALL FRAMING LUMBER TO BE DOUG. FIR LARCH #2.
7. PROVIDE PEST SCREEN IN EACH INTERIOR PLANTER.
8. SEE SHEET 8A FOR SYMBOL SCHEDULE.
12'-0"
LINE OF
SUNKEN
FLOOR
7'-8"
8'-0"
8'-0"
6x10 GIRDER W/ 18" x 8" PIERS @ 48"
U46 HGR. TYP.
19'-10"
1'-0"
5'-4"
30"x15"x12"
CONC. PIER
30"x15"x12"
CONC. PIER
2'-4"
8'-4"
4'-0"
B
1
4"
1'-0"
1/4"
4'-0"
5'-10"
FOUNDATION PLAN
4'-0"
ER
6'-2"
6'-0"
LINE OF
RAISED
FLOOR
4'-0"
17'-6"
18"
CONC.
PIERS
3'-0"
3'-4"
4'-0"
"
5'-4"
4x10 GIRDER
1'-0"
2'-4"
5'-2"
2'-8"
B
1
4'-0"
3'-4"
6x10 GIRDER W/ 18"Ø x 8" PIERS
9'-10"
7'-0"
18"X8"
CONC.
PIER
15"x15"
CONC.
PIER
14'-10"
4'-8"
B
1
3'-0"
1'-0"
72-6"
18"X8"
CONC.
PIER
5'-3"
4x8 GIRDER
8'-0"
18"X8"
CONC.
PIER
21"x21"
CONC.
PIER
2'-0"
37'-0"
8'-0"
18"X8"
CONC.
PIER
A
0
B
1
18" MIN. CRAWL SPACE COVER
W/ 6 MIL BLACK VAPOR
BARRIER THROUGHOUT. LAP
JOINTS 12" MIN. EXTEND UP STEM
WALL & STAPLE TO MUD SILL.
PIER SIZE
15"x15"x12"
6x6 W/
PB66
2'-6"
B
1
15"x15"
CONC.
PIER
24"X8"
CONC.
PIER
4x10 GIRDER W/15"X8" PIERS @ 48" O.C. 3'-10"
4'-0"
4'-0"
15"X8"
CONC.
PIER
8'-0"
8'-4"
2'-10"
18"X8"
CONC.
PIER
4'-0"
7'-6"
B
1
6'-4"x3'-4"x
12" DP. FIREPLACE FTG.
4'-0"
8'-0"
2'-2" 2'-10"
4'-0"
9'-2"
LINE OF
RAISED
fLOOR
1'-10"
5'-6"
4'-0"
4'-0"
B
1
28'-6"
14'-6"
22'-6"
11'-10"
W
3'-10"
LO
8'-10"
71'-0"
37'-0"
24'-6"
Chapter 1: Professional Architectural Careers, Office Practices, and Opportunities
31
drawings. As changes are made throughout the design
process, the drafter must be sure that those changes are
reflected on all affected drawings. When the drafter has
completed checking the plans, the drafting supervisor
will again review the plans before they leave the office.
obtaining a permit varies depending on the local building department and the complexity of the drawings.
Permit reviews generally take several weeks. Once the
review is complete, either a permit is issued or required
changes are made to the plans.
Permit Procedures
Job Supervision
When the plans are complete, the owner will ask several
contractors to estimate the cost of construction. Once a
contractor is selected to build the house, a construction
permit is obtained. Although the drafter is sometimes
responsible for obtaining the permits, this is usually
done by the owner or contractor. The process for
In residential construction, job supervision is rarely
done when working for a designer, but it is quite
often provided when an architect has drawn the
plans. Occasionally, a problem at the job site will
require the designer or drafter to go to the site to help
find a solution.
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to help
you keep current with changes in the building industry.
Address
www.acec.org
www.aceee.org
www.aia.org
www.aibd.org
www.asce.org
www.ashrae.org
www.asla.org
www.aspenational.com
www.aeinstitute.org
www.awa-la.org
www.buildinggreen.com
www.crbt.org
www.corrim.org
Company, Product,
or Service
American Consulting
Engineers Council
American Council for
Energy Efficient Economy
American Institute of
Architects
American Institute of
Building Designers
American Society of Civil
Engineers
American Society of Heating,
Refrigerating, and AirConditioning Engineers
American Society of
Landscape Architects
American Society of
Professional Engineers
Architectural Engineering
Institute
Association for Women in
Architecture
Building Green Inc. (This
site contains a listing of
site-related links based on
LEED standards and CSI
formats.)
Center for Resourceful
Building Technology
Consortium for Research
of Renewable Industrial
Materials
www.thebluebook.com
www.csinet.org
www.eere.energy.gov
www.dreamhomesmag.com
www.eeba.org
Construction Information
Network
Construction Specifications
Institute
DOE Integrated Building for
Energy Efficiency
Dream Homes
Energy and Environmental
Building Association
www.energydesignresources.com
www.energystar.gov
www.afsonl.com
www.greenbuilder.com
www.thegbi.org
www.greenguard.org
www.build.com
www.iesna.org
www.ieee.org
www.nahbrc.org
www.noma.net
www.nsbe.org
www.nspe.org
www.naima.org
Energy Design Resources
Energy Star (appliance
energy standards)
First Source™
Greenbuilder
Green Building Initiative
Green Guard Environmental
Institute
Home Building and Home
Improvement Network
Illuminating Engineering
Society of North America
Institute of Electrical and
Electronics Engineers
National Association of
Home Builders
National Organization of
Minority Architects
National Society of Black
Engineers
National Society of
Professional Engineers
North American Insulation
Manufacturers Association
32
www.residentialarchitect.com
www.raic.org
www.scscertified.com
www.sara-national.org
Architectural Drafting and Design
Residential Architect Online
(bulletin board and buyers’
guide)
Royal Architectural Institute
of Canada
Scientific Certification
Systems
Society of American
Registered Architects
www.oneshpe.org
www.same.org
www.housingzone.com
www.usgbc.org
www.wbdg.org
www.beconstructive.com
Society of Hispanic
Professional Engineers
Society of Military Engineers
Sustainable Buildings
Industry Council
U.S. Green Building Council
Whole Building Design
Guide
Wood Promotion Network
Professional Architectural Careers, Office
Practices, and Opportunities Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
Question 1–8 Why should furniture placement be
considered in the preliminary design process?
1. Letter your name, Chapter 1 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer.
You do not need to write the question. Answers can be
prepared on a word processor if approved by your course
guidelines.
Question 1–10 List five drawings that may be required
for a complete set of house plans in addition to the
five basic drawings.
Question 1–1 List five types of work that a junior
drafter might be expected to perform.
Question 1–9 What would be the minimum drawings
required to get a building permit?
Question 1–11 List and describe the steps of the design
process.
Question 1–12 What are the functions of the drafter in
the design process?
Question 1–2 What three skills are usually required of a
junior drafter for advancement?
Question 1–13 Following the principles of this chapter,
prepare a bubble sketch for a home with the following
specifications:
Question 1–3 What types of drawings should a junior
drafter expect to prepare?
a. 75 × 120' lot with a street on the north side of the lot
Question 1–4 Describe what the junior drafter might be
given to assist in making drawings.
c. South property line 75' long
Question 1–5 List four sources of written information
that a drafter will need to be able to use.
b. A gently sloping hill to the south
d. 40' oak trees along the south property line
e. 3 bedrooms, 2 1/2 baths, living, dining, with sepa-
rate eating area off kitchen
Question 1–6 List and briefly describe different careers
in which drafting would be helpful.
f. Exterior style as per your choice
Question 1–7 What is the purpose of a bubble drawing?
Explain why you designed the house that you did.
CHAPTER 2
Introduction to
Construction Procedures
I
N
T
R
O
D
U
C
T
I
O
N
The architect or designer is often involved with several phases
of preparation before construction begins on a project. The level
of commitment can range from the preparation of plans to the
complete supervision of the entire construction project. Clients
need several items before construction starts, depending on the
complexity or unique requirements of the project. Architects
and designers are often involved with zone changes when
necessary, specification preparation, building permit applications, bonding requirements, the client’s financial statement, the
lender’s approval, and the building contractor’s estimates and
bid procurement.
LOAN APPLICATIONS
Loan applications vary depending on the requirements of the lender. Most applications for construction financing contain similar information. The
construction appraisal requirements proposed by the
Federal Housing Administration (FHA), Veterans
Administration (VA), and U.S. Department of Housing
and Urban Development (HUD) are typical of most
lenders and include:
1. Plot plan (three copies per lot).
2. Prints (three copies per plan). Prints should include
the following:
● Four elevations: front, rear, right side, and left
side.
● Floor plan(s).
● Foundation plan.
● Wall section(s).
● Roof plan.
● Cross sections of exterior walls, stairs, and other
important details.
● Cabinet elevations including a cross section.
● Fireplace detail (manufacturer’s detail if fireplace
is prefabricated).
● Truss detail and engineering (include name and
address of supplier).
●
Heating plan—For forced-air, show size and location of ducts and registers plus cubic feet per
minute (cfm) at each register, and furnace British
thermal units (Btu).
● Location of wall units with watts and cfm at
register.
3. Specifications (one copy per print), which include
information about the following:
● Appliances (make and model numbers).
● Smoke detectors (make and model number and
“Direct Wire”).
● Typical detail for each plant type (if the project is
landscaped).
● Plumbing fixtures (make and model number, size,
and color).
● Carpet (brand, style, and directory number).
● Carpet pad (brand, style, thickness, and directory
number).
● Truss manufacturer (name and address).
● Fireplace (if applicable) manufacturer and model
number.
4. Public Utility District (PUD) or heating contractor’s
heat loss calculation (one per specification sheet).
Room-by-room Btu heat loss values showing the
total Btu heat loss for the dwelling as well as the total
output of the heating system.
5. Proposed sale price.
6. Copy of earnest money agreement, blank or completed for a presale. Earnest money is a good faith
sum of money given to bind a contract, for example
an agreement to purchase real property, or a commitment fee to ensure an advance of funds by a
lender. In a real estate transaction, the money is
applied to the purchase price and can be forfeited
if the purchaser fails to carry out the terms of the
agreement. A presale is an exclusive or private
sale that is made before construction begins. For
a presale, the buyer and the builder must sign the
specification sheet.
33
34
Architectural Drafting and Design
Most lending institution applications are not as comprehensive as that of the FHA, but some can require
additional information. The best practice is to research
the lender to identify the needed information. A wellprepared set of documents and drawings usually stands
a better chance of funding.
INDIVIDUAL APPRAISAL
REQUIREMENTS
An individual appraisal is required when a person or
persons want to obtain financing to purchase or build a
home or other building.
The subdivision can be FHA approved, in which
case, the FHA approval is submitted to the lender. A
subdivision, also called a plat, divides land into pieces,
also known as plots or lots, that are easier to develop
and sell. The original land divided into individual
parcels is a subdivision. A subdivision used for housing is also known as a housing subdivision, housing
development, or community. Generally, a subdivision
that is not FHA approved contains the following information when submitted to a lender:
1. Total number of lots in the subdivision.
2. Evidence of acceptance of streets and utilities by local
authorities for continued maintenance.
1. Location map and a copy of the recorded plat and
covenants.
2. A letter from the builder that includes the following
information:
a. The number of lots in the area owned by the
builder and the number of lots proposed to be
built on.
b. The number of homes presently under construction and the number completed and unsold.
If the builder has not worked with FHA previously,
an equal employment opportunity certificate and
an affirmative fair housing marketing plan must
be submitted for either a master or an individual
appraisal request.
CHANGE ORDERS
Any physical change in the plans or specifications should be submitted to FHA or
the lender. The change order notes whether the
described change is an increase or decrease in value
and by what dollar amount. The change order must
be signed by the lender, the builder, and by the purchaser if the structure is sold. A typical change order
is located with Problem 2–3 on page 42 and on the
Student CD.
3. One copy of the recorded plat and covenants.
Covenants, also called deed restrictions, are legal
agreements setting the conditions and restrictions for the property. Covenants, conditions, and
restrictions (CC&R) is a commonly used short
form in real estate business. CC&Rs are limitations
and rules placed on a group of homes by a builder,
developer, neighborhood, or homeowner association. All condominiums and townhomes, and most
planned unit developments and established neighborhoods have CC&Rs.
MASTER APPRAISAL
REQUIREMENTS
A master appraisal is required when a company wants
to obtain financing to develop a subdivision where
several homes will be constructed.
A minimum of five lots for each plan type is normally
required for a master appraisal. The subdivision should
be FHA or VA approved and contain the following
information:
BUILDING PERMITS
The responsibility of completing the building
permit application can fall to the architect,
designer, or builder. The architect should contact the
local building official to determine the process to be
followed. Generally, the building permit application
is a basic form that identifies the major characteristics
of the structure to be built, the legal description and
location of the property, and information about the
applicant. The application is usually accompanied by
two sets of plans and up to five sets of plot plans. The
fee for a building permit usually depends on the estimated cost of construction. The local building official
determines the amount, which is based on a standard
schedule at a given cost per square foot. The fees are
often divided into two parts: a plan-check fee paid
upon application and a building-permit fee paid when
the permit is received.
Other permits and fees may or may not need to
be paid at this time. In some cases the mechanical,
sewer, plumbing, electrical, and water permits are
Chapter 2: Introduction to Construction Procedures
obtained by the general contractor or subcontractors.
Water and sewer permits can be expensive, depending on the local assessments for these utilities. A
typical building permit application is found with
Problem 2–1 on page 41 and on the Student CD for
this text.
CONTRACTS
Building contracts can be very complex
documents for large commercial construction or short forms for residential projects. The
main concern in the preparation of the contract is
that all parties understand what will specifically be
completed in the project, in what period of time, and
for what cost. The contract becomes an agreement
between the client, general contractor, and architect.
The Student CD includes an example of a typical
building contract.
It is customary to specify the date that the project is
to be completed. On some large projects, completion
dates for the various stages of construction are specified. Usually the contractor receives a percentage of
the contract price for the completion of each stage of
construction. Payments are typically made three or
four times during construction. Another method is
for the contractor to receive partial payment for the
work done each month. Verify the method used with
the lending agency.
The owner is usually responsible for having the
property surveyed. A survey determines the boundaries, area, or elevations of land, structures, and other
features by means of measuring angles and distances.
The architect can be responsible for administering
the contract. As specified on typical building contracts, the contractor is responsible for construction
and for the security of the site during the construction period.
Certain kinds of insurance are required during
construction. The contractor is required to have
liability insurance and a performance bond. The liability insurance protects the contractor against being
sued for accidents occurring on the site. The performance bond guarantees the contractor completes
the work in a professional and timely manner or
the insurance company covers the cost. The owner
is required to have property insurance, including
fire, theft, and vandalism. Workers’ compensation
is another form of insurance that provides income
for contractors’ employees if they are injured at
work. The contractor must be licensed, bonded, and
35
insured under the requirements of the state where
the construction occurs.
The contract describes conditions under which it can
be ended. A contract can be terminated if one party fails
to comply with requirements, if one of the parties is
disabled or dies, and for several other reasons.
The two kinds of contracts in use for most construction are the fixed-sum contract and the cost-plus
contract. Each contract type offers advantages and
disadvantages.
Fixed-sum contracts, sometimes called lump-sum
contracts, are used most often. With a fixed-sum contract, the contractor agrees to complete the project for
a certain amount of money. The greatest advantage of
this kind of contract is that the owner knows the exact
cost in advance. However, the contractor does not
know what hidden problems may be encountered, and
so the contractor’s price is likely to be high enough
to cover unforeseen circumstances, such as excessive
rock in the excavation or sudden increases in the cost
of materials.
A cost-plus contract is one in which the contractor
agrees to complete the work for the actual cost, plus a
percentage for overhead and profit. The advantage of
this type of contract is that the contractor does not have
to allow for unforeseen problems. A cost-plus contract
is also useful when changes are to be made during the
course of construction. The main disadvantage of this
kind of contract is that the owner does not know the
exact cost until the project is completed. To overcome
this disadvantage, the contractor generally reports costs
and is paid after specific phases of construction. The
completion and payment for each phase should be
specified in the contract. Regardless of the payment
schedule, the contractor should report progress and
cost periodically and never wait until the end of the
project. A typical building contract is located on the
Student CD.
COMPLETION NOTICES
The completion notice is a document that
is posted in a noticeable place on or near
the structure. This legal document notifies all parties
involved in the project that work has been substantially
completed. There can be a very small part of work or
cleanup to be done, but the project, for all practical
purposes, is complete. The completion notice must be
recorded in the local jurisdiction. Completion notices
serve several functions. Subcontractors and suppliers
have a certain given period of time to file a claim or
36
lien against the contractor or property owner to obtain
payment for labor or materials that have not been paid.
Lending institutions often hold a percentage of funds
for a given period of time after the completion notice
has been posted. It is important for the contractor to
have this document posted so the balance of payment
can be made. The completion notice is often posted
in conjunction with a final inspection by the local
building official and the client. A series of inspections are conducted at different phases throughout the
course of construction. The final inspection is the last
opportunity to confirm that all work has been completed and the home or structure is ready to occupy.
A checklist containing specific practices that must be
accomplished and the proper methods and materials
used for completion of each practice is evaluated.
These inspections are always conducted by a local
building official, and often by the lender and property owner. Most lenders require that all building
inspection reports be submitted before payment is
given, and some also require a private inspection by
an agent of the lender. A sample completion notice
is located with Problem 2–4 on page 43 and can also
be found on the Student CD.
CONSTRUCTION ESTIMATES
A statement of probable construction cost is a forecast of construction costs prepared by the architect or
designer during the design process to give the client
an approximation of the expected cost to construct
the building. This is an important responsibility of
the architect or designer. Clients generally want to
build a home that they can afford. Determining a
budget in advance and designing within that budget
can save serious trouble. Architects or designers need
to inform the clients if their ideas and desires do not
match the budget.
Construction estimating is an analysis of construction cost based on a detailed examination of
materials and labor for all work to be completed on
the project. The construction estimate or elements of
the estimate are often referred to as a takeoff. A takeoff carefully identifies the construction materials for a
specific aspect of the project, such as a lumber takeoff.
The lumber takeoff includes the cost of every piece
of lumber, sheathing, trusses, engineered joists, and
hardware needed for the project. An electrical takeoff,
for example, includes all wire, outlets, switches, junction boxes, and every other item used for the rough-in
of the electrical part of the project. The finish electrical
fixtures are often found in a separate list of materials.
Architectural Drafting and Design
An accurate cost estimate requires an orderly and
organized system of identifying and pricing every construction item in a phase of construction and for the
entire project.
Construction bids can be part of the construction
estimate process when an architect, designer, or general contractor seeks estimates from subcontractors
covering the materials and cost of their part of the
project. The general contractor is responsible for working directly with the architect, designer, or property
owner to complete the entire project in a quality and
professional manner. Subcontractors complete specific
aspects of the project. Many types of subcontractors,
such as foundation, framing, electrical, plumbing, and
heating, ventilation, and air-conditioning (HVAC),
can be asked to give separate bids to the architect or
general contractor.
Construction bids are often obtained by the architect or a general contractor for the client. The purpose
is to get the best price for the best work. Some projects
require that work be given to the lowest bidder, while
other projects do not necessarily go to the lowest bid.
In some situations, especially in the private sector,
other factors are considered, such as an evaluation of
the builder’s history based on quality, ability to meet
schedules, cooperation with all parties, financial stability, and license, bond, and insurance.
The bid becomes part of the legal documents for
completion of the project. The legal documents usually
include plans, specifications, contracts, and bids. The
architect and client should know clearly what the bid
includes. The following items are part of a total analysis
of costs for residential construction:
1. Plans.
2. Permits, fees, and specifications.
3. Roads and road clearing.
4. Excavation.
5. Water connection (well and pump).
6. Sewer connection (septic).
7. Foundation, waterproofing.
8. Framing, including materials, trusses, and labor.
9. Fireplace, including masonry and labor.
10. Plumbing, both rough and finished.
11. Wiring, both rough and finished.
12. Windows.
13. Roofing, including sheet metal and vents.
14. Insulation.
15. Drywall or plaster.
Chapter 2: Introduction to Construction Procedures
16. Siding.
17. Gutters, downspouts, sheet metal, and rain drains.
37
Refer to the Student CD: COUNTING THE COST, for
more information.
18. Concrete flatwork and gravel.
19. Heating.
CONSTRUCTION INSPECTIONS
20. Garage and exterior doors.
The basics of construction inspections were introduced earlier. When the architect or designer is responsible for the supervision of the construction project,
then it is necessary to work closely with the building
contractor to get the proper inspections at the necessary times. Two types of inspections occur most
frequently. The regularly scheduled code inspections
required during specific phases of construction help
ensure that the construction methods and materials
meet local and national code requirements. The general intent of these inspections is to protect the safety
of the occupants and the public. The second common
type of inspection is lender inspections, which are
conducted by the lender during certain phases of construction. Lender inspections ensure that materials
and methods described in the plans and specifications
are being used. The lender has a valuable interest in
the construction quality. If the materials and methods
are inferior or not of the standard expected, then the
value of the structure may not be what the lender had
considered when a preliminary appraisal was made.
Another reason for inspections, and probably the
reason that the builder likes best, has to do with disbursement. Included as part of the lender inspections,
disbursement inspections are requested at various
times, such as monthly, or they can be related to a specific disbursement schedule, such as four times during
construction. If the disbursement inspection finds the
work to be satisfactory, then funds are released to pay
the builder for that completed work.
When architects or designers supervise the total
construction, then they must work closely with the
contractor to make certain the project is completed in
a timely manner. When a building project remains idle,
the overhead costs, such as construction interest, begin
to add up quickly. A contractor who bids a job high
but builds quickly can save money in the final analysis. Some overhead costs go on daily even when work
has stopped or slowed. The contractor or construction supervisor should also have a good knowledge of
scheduling so subcontractors are available in proper
sequence, and inspections are obtained at the proper
time. If an inspection is requested when the project
is not ready, the building official may charge a fee for
excess time spent. Always try to develop a good rapport with building officials so each encounter goes as
smoothly as possible.
21. Painting and decorating.
22. Trim and finish interior doors, including material
and labor.
23. Underlayment.
24. Carpeting, including the amount of carpet and pad-
ding, and the cost of labor.
25. Vinyl floor covering—amount and cost of labor.
26. Formica.
27. Fixtures and hardware.
28. Cabinets.
29. Appliances.
30. Intercom or stereo system.
31. Vacuum system.
32. Burglar alarm.
33. Weather stripping and venting.
34. Final grading, cleanup, and landscaping.
35. Supervision, overhead, and profit.
36. Subtotal of land costs.
37. Financing costs.
As previously mentioned, the architect or general
contractor is often responsible for the complete cost
estimate and for getting bids. Cost-estimating education is normally a good idea for learning how to
accurately and completely prepare a cost estimate.
A variety of cost-estimating software programs are
available. One way to find these software programs
is to search the Internet with a search subject such
as “construction estimating.” Microsoft Excel is a
convenient and commonly used tool for preparing
cost estimates. This program allows you to set up
your own cost-estimating format that tracks and
automatically calculates subtotals and totals for the
estimate, bid, actual cost, cumulative cost, payee or
subcontractor, check number, and date of payment.
A Microsoft Excel sample cost estimate sheet for a
2366-square-foot new home construction is shown
in Figure 2-1.
Counting the Cost content on the Student
CD includes information and analysis about
the construction cost and general fees for the
construction and financing of a new home.
38
Architectural Drafting and Design
NEW HOME CONST.
2366 SQ FT
Updated 2/26/10
EXPENSE
Bid/Est.
Cumulative
Actual
Cumulative
Payee
Appliances
10,000
10,000
budget
Backfill
1000
11,000
estimate
Bathroom Fixtures
3500
14,500
estimate
Cabinets
25,000
39,500
budget
Carpets
8500
48,000
estimate @ $45 / sq yd
Carpets Labor
4732
52,732
estimate @ $2 / sq yd
Cleanup
1000
53,732
estimate
Concrete Flatwork/Patios
8000
61,732
estimate @ $2.50 / sq ft
Concrete Pumping
875
63,857
estimate
Concrete Stairs
1250
62,982
estimate lin ft @ $10 / lin ft
Countertops
3000
66,857
estimate @ $22 / sq ft
0
66,857
2500
69,357
Ck #
0
Crane Truck & Operator
Decks
Demolition/Tree Removal
estimate
0
69,357
Doors-Exterior
12,700
82,057
2 @325; IWP #645 $12,000
Doors-Interior
18,500
100,557
estimate
Drywall
11,625
112,182
Chapperal
Electrical-Finish
5500
117,682
Lite Rite Electric Inc.
Electrical-Rough
12,000
129,682
Lite Rite Electric Inc.
Electrical-Temporary
750
130,432
Electrical-Underground
4500
134,932
Electricity
0
134,932
Equipment Rental
0
134,932
Excavation
1000
135,932
estimate
Finish Carpentry-Labor
10,000
145,932
estimate
Finish Carpentry-Materials
5000
150,932
estimate
Fireplace Mantels
1575
152,507
D Luchs
Foundation Labor
15,260
167,767
Jet Concrete
0
167,767
w/ labor
24,000
191,767
Corban $2,400. Bailey $24,750
Foundation Materials
Framing Labor
Framing Materials
35,000
226,767
BMC 37K Lumbermans 30K
Furnace & Mechanical
10,000
236,767
Wilfert or Rite Way
Garage Doors
3500
240,267
Edelen
Ga
FIGURE 21 A sample cost-estimate sheet for a 2366-square-foot new home construction, created using Microsoft Excel.
Date
Chapter 2: Introduction to Construction Procedures
39
NEW HOME CONST.
2366 SQ FT
Updated 2/26/10
EXPENSE
Bid/Est.
Cumulative
Actual
Cumulative
Payee
Gutters/Downspouts
1000
243,267
estimate
Hardware-Bath
450
243,717
estimate
Hardware-Cabinets
975
244,692
estimate
Insulation
5200
249,892
Knez
Insurance & Licenses
0
249,892
Labor-Misc.
0
251,892
Landscaping
0
249,892
Light Fixtures
2000
251,892
estimate
Lumber/Materials-Misc.
27,500
279,392
Parr Lumber
Masonry Veneer & Frplc
28,000
307,392
Dave Clooten
0
307,392
Painting
10,000
317,392
estimate
Permits and Plan Ckk Fee
4600
321,992
County $1,200 paid
Plans and Specs
10,000
331,992
Architectural Designer $10,000 paid
Misc. Const. Expense
Plumbing-Finish
2500
344,992
Fixtures estimate
Plumbing-Rough/finish
10,500
342,492
Fowler $6,500; spkr sys $4,000
Pre-Wire Electronics
1700
346,692
Quadrant
Rain Drains
1000
347,692
estimate
Roof
20,000
367,692
Bliss Roofing Grand Manor
Security Systems
1500
369,192
Quadrant
Sewer Lines & Cesspools
6000
375,192
Nussbaumer
Sheet Metal/Ducting
0
375,192
see Wilfert heat
Siding Labor
3500
378,692
estimate
Siding Materials
3500
382,192
estimate
Skylights/Greenhouses
0
382,192
Steel Pipes
0
382,192
Structural Engineer
0
382,192
Supervision
0
382,192
Tile/Stone Floors
10,000
392,192
Tools & Hardware-Misc.
0
392,192
Truck Hauling
0
392,192
Underlayment
0
392,192
Water Main Extension
0
392,192
Water Meter Trench
0
392,192
Weather stripping
1000
393,192
estimate
Windows
31,500
424,692
Pella
0
424,692
Wood Floors
FIGURE 21 Continued
@$10 / sq ft
I-joist systems
Ck #
Date
40
Architectural Drafting and Design
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you find information related to construction supervision procedures and keep current with trends in the
industry.
Address
www.fha.gov
Company, Product,
or Service
Federal Housing
Administration
www.nahb.org
www.sagecre.com
www.hud.gov
www.va.gov
National Association of
Home Builders
Sage Software
U.S. Department of Housing
and Urban Development
U.S. Department of Veterans
Affairs
Introduction to Construction Procedures Test
See CD
for more
information
QUESTIONS
●
Project location address: 3456 Barrington Drive,
your city and state
●
Nearest cross street: Washington Street
●
Subdivision name: Barrington Heights
●
Township: 2S
●
Range: 1E
●
Section: 36
●
Tax lot: 2400
●
Lot size: 15,000 sq ft
●
Building area: 2000 sq ft
●
Basement area: None
●
Garage area: 576 sq ft
●
Stories: 1
●
Bedrooms: 3
●
Water source: Public
●
Sewage disposal: Public
●
Estimated cost of labor and materials: $88,500
●
Plans and specifications made by: You
●
Owner’s name: Your teacher; address and phone may
be fictitious
PROBLEMS
●
DIRECTIONS: All forms must be neatly hand-lettered or typed,
unless otherwise specified by your instructor.
Builder’s name: You, your address, and your phone
number
●
You sign as applicant
●
Homebuilder’s registration number: Your social
security number or another fictitious number
●
Date: Today’s date
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 2 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You
do not need to write out the question. Answers can be
prepared on a word processor if approved by your course
guidelines.
Question 2–1 Define and list the elements of the
following construction-related documents:
a. Loan applications
b. Contracts
c. Building permits
d. Completion notices
e. Bids
f. Change orders
Question 2–2 Outline and briefly discuss the required
building construction inspections.
Problem 2–1 Access and print the building permit
application on the Student CD, or copy the building
permit application on page 41. Complete the
application using this information.
Chapter 2: Introduction to Construction Procedures
Problem 2–2 Access and print the building contract
on the Student CD. Complete the contract using this
information:
●
Date: Today’s date
●
Name yourself as the contractor and your teacher as
the owner. (Give complete first name, middle initial,
and last name where names are required.)
●
ARTICLE I: Construction of approximate
2000-square-foot house to be located at 3456
Barrington Drive, your city and state. Also
known as Lot 8, Block 2, Barrington Heights,
your county and state.
●
Drawing and specifications prepared by you.
●
All said work to be done under the direction
of you.
●
ARTICLE II: Commence work within 10 days and
substantially complete on or before. (Give a date
four months from the date of the contract.)
●
ARTICLE III: $88,500. Payable at the following
times:
41
1. One-third upon completion of the foundation.
2. One-third upon completion of drywall.
3. One-third 30 days after posting the completion
notice.
● ARTICLE X: Insurance $250,000; $500,000; and
$50,000.
● ARTICLE XVIII: Give the owner’s name, address,
and phone number—a fictitious address and phone
number may be used if preferred. Give your name and
address as the contractor.
● ARTICLE XX: This contract amount is valid for a
period of 60 days. If, for reasons out of the contractor’s control, construction has not begun by the
end of this 60-day period, contractor has the right
to rebid and revise the contract.
Problem 2–3 Access and print the change order form
found on the Student CD, or copy the change order form
on page 42. Complete the form using this information:
● Date: Today’s date
● Project name: Your teacher’s name
42
Architectural Drafting and Design
●
Location: 3456 Barrington Drive, your city and
state. Also known as Lot 8, Block 2, Barrington
Heights, your county and state.
● Description of change: Add a 24" × 48" insulated
tempered flat glass skylight in the vaulted ceiling
centered in the entry foyer.
● Additional cost: $850
● Adjusted total project cost: $89,350
● Signatures
Problem 2–4 Access and print the completion notice
found on the Student CD or copy the completion
notice on page 43. Complete the top half of the
form above the double line only. The rest of the
information is for the official notary public and
recording officer. Use this information:
●
Date: Today’s date
●
Owner or mortgagee: Your name
●
P.O. address: Your address
Chapter 2: Introduction to Construction Procedures
The Stevens-Ness form has been reproduced with the permission of Stevens-Ness Law Publishing Co. No further copying or reproduction in any
form is permitted without the express permission of the publisher.
43
CHAPTER 3
Architectural Drafting
Equipment
I
N
T
R
O
D
U
C
T
I
O
N
Manual drafting is the term used to describe traditional pencil
or ink drafting. Manual drafting tools and equipment are available from a number of vendors of professional drafting supplies. For accuracy and durability, always purchase high-quality
equipment. This chapter introduces a variety of manual drafting
tools and their proper use. Additional products are described in
the Supplemental Reference found on the Student CD.
DRAFTING SUPPLIES
Whether equipment is purchased in a kit or by the
individual tool, the following items are the minimum
normally needed for manual drafting:
●
One mechanical lead holder with 4H, 2H, H, and F
grade leads. This pencil and lead assortment allows
for individual flexibility of line and lettering control,
or for use in sketching. The lead holder and leads are
optional if automatic pencils are used.
● One 0.3 mm automatic drafting pencil with 4H, 2H,
and H leads.
● One 0.5 mm automatic drafting pencil with 4H, 2H,
and F leads.
● One 0.7 mm automatic drafting pencil with 2H, H,
and F leads.
● One 0.9 mm automatic drafting pencil with H, F, and
HB leads. Automatic pencils and leads are optional if
lead holders and leads are used.
● Lead sharpener (not needed if the lead holder is
omitted).
● 6" bow compass.
●
Dividers.
Eraser.
● Erasing shield.
● 30°–60° triangle.
● 45° triangle.
● Irregular curve.
● Adjustable triangle (optional).
●
44
●
Scales:
1. Triangular architect’s scale.
2. Triangular civil engineer’s scale.
● Drafting tape.
● Architectural floor plan template for residential plans,
with 1/4" = 1'−0" scale.
● Circle template with small holes.
● Lettering guide.
● Sandpaper sharpening pad.
● Dusting brush.
Not all of the items listed here are used in every
school or workplace. Additional equipment and supplies may be needed depending on the specific application, for example:
●
Technical pen set.
● Drafting ink.
● Lettering template.
● Assorted architectural drafting templates.
DRAFTING FURNITURE
Special tables and chairs are available for
professional drafting use. Refer to the
Student CD: DRAFTING FURNITURE, for more
information.
DRAFTING PENCILS AND LEADS
Manual drafting is generally done using pencils. The
two most commonly used pencils are mechanical
and automatic pencils. Most manual drafters prefer
automatic pencils.
Mechanical Pencils
The term mechanical pencil refers to a pencil that
requires a piece of lead to be manually inserted.
Special sharpeners are available to help maintain a
conical point.
Chapter 3: Architectural Drafting Equipment
45
Automatic Pencils
The term automatic pencil refers to a pencil with
a lead chamber that, at the push of a button or tab,
advances the lead from the chamber to the writing tip.
Automatic pencils are designed to hold leads of one
width that do not need to be sharpened. These pencils
are available for leads 0.3 mm, 0.5 mm, 0.7 mm, and
0.9 mm thick. Many drafters have several automatic
pencils, each with a different grade of lead hardness,
used for a specific application.
Lead Grades
Several different grades, or hardness, of leads are used for
drafting. Your selection depends on the amount of pressure you apply and other technique factors. You should
experiment until you identify the leads that give you the
best quality. Leads commonly used for thick lines and
lettering range from 2H to F. Leads for thin lines range
from 4H to H, depending on individual preference.
Construction lines for layout and guidelines for lettering
are very lightly drawn with a 6H or 4H lead. Figure 3-1
shows the different lead grades. Generally, leads used for
sketching are softer than those used for formal drafting.
Good sketching leads are H, F, or HB grades.
Polyester and Special Leads
Polyester leads, also known as plastic leads, are for
drawing on polyester drafting film, often called by its
trade name, Mylar. Plastic leads come in grades equivalent to F, 2H, 4H, and 5H and are usually labeled with
an S, as in 2S. Some companies make a combination
lead for use on both vellum and polyester film. See
Chapter 4 for information about drafting media, such
as vellum and polyester film.
Colored leads have special uses. Red or yellow lead
is commonly used to make corrections. Red or yellow
lines appear black on a print. Blue lead can be used on
9H 8H 7H 6H 5H 4H
3H 2H H F HB B
2B 3B 4B 5B 6B 7B
HARD
MEDIUM
SOFT
4H AND 6H ARE
COMMONLY USED
FOR CONSTRUCTION
LINES.
H AND 2H ARE
COMMON LEAD
GRADES USED
FOR LINE WORK.
H AND F ARE
FOR LETTERING
AND SKETCHING.
THESE GRADES
ARE FOR ARTWORK.
THEY ARE TOO
SOFT TO KEEP A
SHARP POINT AND
THEY SMUDGE
EASILY.
FIGURE 31 Range of lead grades.
an original drawing for information that is not to show
on a print, such as notes, lines, and outlines of areas to
be corrected. Blue lines do not appear on the print when
the original is run through a diazo machine but do
reproduce in the photocopy process if not very lightly
drawn. Some drafters use light blue lead for layout work
and guidelines. Drawing reproduction is discussed in
Chapter 4, with information about the diazo and photocopy processes.
Basic Pencil Motions
A mechanical pencil must be kept sharp with a slightly
rounded point. A point that is too sharp breaks easily,
but a point that is too dull produces fuzzy lines. Keep
the pencil aligned with the drafting instrument and
tilted at an angle of approximately 45° in the direction
you are drawing. Always pull the pencil. If you are
right-handed, it is recommended that you draw from
left to right for horizontal lines, and from bottom to
top for vertical lines. Left-handed people draw from
right to left and top to bottom. It is very important to
keep lines uniform in width. This is done by keeping
the pencil at uniform sharpness and by rotating the
pencil as you draw. This rotation helps keep the lead
from having flat spots that cause the line to vary in
width and become fuzzy. Even pressure is also needed
to help ensure a uniform line weight. Your lines need
to be crisp and dark. Keep practicing, so you can draw
high-quality lines.
When using an automatic pencil, keep it straight
from side to side and tilted about 40° with the direction
of travel. Try not to tilt the lead under or away from
the straightedge. Automatic pencils do not require
rotation, although some drafters feel that better lines
are made by rotating the pencil. Provide enough pressure to make a line dark and crisp. Figure 3-2 shows
some basic pencil motions.
TECHNICAL PENS
AND ACCESSORIES
Technical pens provide excellent inked lines.
Refer to the Student CD: TECHNICAL PENS AND
ACCESSORIES, for more information.
ERASERS AND ACCESSORIES
The common shapes of erasers are rectangular and
stick. The stick eraser works best in small areas. Select
an eraser that is recommended for the particular material used.
46
Architectural Drafting and Design
India Ink Refill Eraser
The India ink refill eraser is for removing India ink
from vellum or film. It contains a solvent that dissolves
the binding agents in the ink and the vinyl, and then
removes the ink. This eraser does not work well with
pencil lead.
ROTATE PENCIL
AS YOU DRAW
(OPTIONAL FOR
AUTOMATIC
PENCIL).
PENCIL MOVES
FROM BOTTOM
TO TOP.
KEEP AUTOMATIC
PENCIL 90° TO SURFACE AND
MECHANICAL PENCIL 45°
TO SURFACE.
PENCIL MOVES
LEFT TO RIGHT.
FIGURE 32 Basic pencil motions. Note, these pencil movements should be reversed (top to bottom, right to left) for lefthanded people.
Erasers Used for Drafting
White Pencil Eraser
The white pencil eraser is used for removing pencil
marks from paper. It contains a small amount of pumice
but can be used as a general-purpose pencil eraser.
Pumice is an abrasive material.
Pink Pencil Eraser
A pink pencil eraser contains less pumice than the
white pencil eraser. It can be used to erase pencil
marks from most kinds of office paper without doing
any damage to the surface.
Soft-Green or Soft-Pink Pencil Erasers
Soft-green and soft-pink erasers contain no pumice and
are designed for use on even the most delicate types
of paper without damaging the surface. The color difference is maintained only to satisfy long-established
individual preferences.
Kneaded Eraser
Kneaded erasers are soft, stretchable, and nonabrasive.
They can be formed into any size you want. Kneaded
erasers are used for erasing pencil and charcoal.
Kneaded erasers are also used for shading. In addition,
kneaded erasers are handy for removing smudges from
a drawing and for cleaning a drawing surface.
Vinyl Eraser
A vinyl or plastic eraser contains no abrasive material.
This eraser is used on polyester drafting film to erase
plastic lead or ink.
Erasing Tips
In erasing, the idea is to remove an unwanted line or
letter, not the surface of the paper or polyester film.
Erase only hard enough to remove the unwanted feature. However, you must provide enough pressure
to eliminate the feature completely. If the entire item
does not disappear, ghosting results. A ghost is a line
that should have been eliminated but still shows on a
print. Lines that have been drawn so hard as to make a
groove in the drawing sheet can also cause a ghost. To
remove ink from vellum, use a pink or green eraser, or
an electric eraser. Work the area slowly. Do not apply
too much pressure or erase in one spot too long, or you
will go through the paper. On polyester film, use a vinyl
eraser and/or a moist cotton swab. The inked line usually comes off easily, but use caution. If you destroy the
matte surface of either a vellum or film sheet, you will
not be able to redraw over the erased area. Matte is a
surface with some texture and is not glossy.
Electric Erasers
Professional manual drafters use electric erasers, available in cord and cordless models. When working with
an electric eraser, you do not need to use very much
pressure, because the eraser operates at high speed. The
purpose of the electric eraser is to remove unwanted
items quickly. Use caution, because these erasers can
also remove paper quickly! Eraser refills for electric
erasers are available in all types.
Erasing Shields
Erasing shields are thin metal or plastic sheets with
a number of differently shaped slots and holes. They
are used to erase small, unwanted lines or areas. For
example, if you have a corner overrun, place one of
the slots or holes of the erasing shield over the area to
be removed while covering the good area. Now, erase
through the slot or hole to erase the unwanted feature.
Cleaning Agents
Special eraser particles are available in a shaker-top
can or a pad. Both types are used to sprinkle the eraser
particles on a drawing to help reduce smudging and
Chapter 3: Architectural Drafting Equipment
to keep the drawing and your equipment clean. The
particles also help float triangles, straightedges, and
other drafting equipment to reduce line smudging.
Use this material sparingly because too much of it can
cause your lines to become fuzzy. Cleaning powders
are not recommended for use on ink drawings or on
polyester film.
47
HOLD THE
COMPASS HERE
DURING USE
GEAR MESH
CENTER-WHEEL
ADJUSTING
SCREW
Dusting Brushes
Use a dusting brush to remove eraser particles from
your drawing. Doing so helps reduce the possibility
of smudges. Avoid using your hand to brush away
eraser particles, because the hand tends to cause messy
smudges. A clean, dry cloth works better than your hand
for removing eraser particles, but a brush is preferred.
DRAFTING INSTRUMENTS
This chapter began with a general list of required drafting instruments. Find a supplier that provides professional-quality drafting instruments of the type and
characteristics described in the following section.
ONE LEG
REMOVABLE
TO ADD IN
EXTENSION
REMOVABLE
LEAD
REMOVABLE
NEEDLE
POINT
Kinds of Compasses
Compasses are used to draw circles and arcs. A compass
is especially useful for large circles. However, using a
compass can be time consuming. Always use a template,
whenever possible, to make circles or arcs quickly.
There are several basic types of drafting compasses:
●
The drop-bow compass is mostly used for drawing
small circles. The center rod contains the needle
point and remains stationary while the pencil, or pen,
leg revolves around the point.
● The center-wheel bow compass is most commonly
used by professional drafters. This compass operates on the screw-jack principle by turning the large
knurled center wheel, as shown in Figure 3-3.
● The beam compass is a bar with an adjustable needle
and a pencil or pen attachment for swinging large
arcs or circles. Also available is a beam that is adaptable to the bow compass. Such an adapter works
only on bow compasses that have a removable break
point, not on the fixed-point models.
FIGURE 33 Center-wheel bow compass and its parts.
The compass lead should, in most cases, be one grade
softer than the lead you use for straight lines because
less pressure is normally used on a compass than a
pencil. Keep the compass lead sharp. An elliptical point
is commonly used with the bevel side inserted away
from the needle leg. Keep the lead and the point equal
in length. Figure 3-5 shows properly aligned and sharpened points on a compass.
Use a sandpaper block to sharpen the elliptical
point of a compass lead. Be careful to keep the graphite
residue away from your drawing and off your hands.
Compass Use
Keep both the compass needle point and the lead point
sharp. The points are removable for easy replacement.
The better compass needle points have a shoulder,
which helps keep the point from penetrating the paper
more than necessary. Compare the needle points in
Figure 3-4.
COMPASS OR DIVIDER
POINT WITH SHOULDER
COMPASS OR DIVIDER
POINT WITHOUT SHOULDER
FIGURE 34 Common compass points.
48
Architectural Drafting and Design
3/8"
1/4" at about 45°
FIGURE 35 Properly sharpened and aligned elliptical compass lead.
ADJUSTING THE DIVIDER
Remove excess graphite from the point with a tissue or
cloth after sharpening. Sharpen the lead often.
Some drafters prefer to use a conical compass
point. This is the same point used in a mechanical
pencil. If you want to try this point, sharpen a piece
of lead in a mechanical pencil, and then transfer it to
your compass.
If you are drawing a number of circles from the
same center, you will find the compass point causes
an ugly hole in your drawing sheet. Reduce the chance
of making such a hole by placing a couple of pieces of
drafting tape at the center point for protection. There
are also small plastic circles available for this purpose.
Place one of the plastic circles at the center point, and
then pierce the plastic with your compass point.
Dividers
Dividers are used to transfer dimensions or to divide a
distance into a number of equal parts.
Some drafters prefer to use a bow divider because the
center wheel provides the ability to make fine adjustments easily. Also, the setting remains more stable than
with standard friction dividers.
A good divider should not be too loose or too tight.
It should be easily adjustable with one hand. In fact,
you should control dividers with one hand as you lay
out equal increments or transfer dimensions from one
feature to another. Figure 3-6 shows how the dividers
should be handled.
Proportional Dividers
Proportional dividers are used to reduce or enlarge
an object without mathematical calculations or scale
manipulations. The center point of the divider is set
at the correct point for the proportion you want. Then
measure the original size object with one side of the
proportional divider, and the other side automatically
determines the new reduced or enlarged size.
USING THE DIVIDER
FIGURE 36 Using the divider.
Parallel Bar
The parallel bar slides up and down the drafting
board on cables that are attached to pulleys mounted
at the top and bottom corners of the table as shown in
Figure 3-7. The function of the parallel bar is to allow
you to draw horizontal lines. Vertical lines and angles
are made with triangles in conjunction with the parallel bar as demonstrated in Figure 3-8. Angled lines are
made with standard or adjustable triangles.
The parallel bar is commonly found in architectural
drafting offices because architectural drawings are frequently very large. Architects and architectural drafters
often need to draw straight lines that are the full length
of their boards, and the parallel bar is ideal for such
lines. The parallel bar can be used with the board in an
CABLE
CABLE
PULLEYS
TENSION
BRACKET
FIGURE 37 Parallel bar.
BAR
Chapter 3: Architectural Drafting Equipment
49
angles of any degree. A protractor is an instrument used
to measure angles.
Architectural Templates
FIGURE 38 Drawing vertical lines with the parallel bar and
triangle.
inclined position. Triangles and the parallel bar must be
held securely when used in any position, which makes
drafting more comfortable. Professional models have a
brake that can lock the parallel bar in place during use.
Triangles
There are two standard triangles. One has angles of
30°–60°–90° and is known as the 30°–60° triangle.
The other has angles of 45°–45°–90° and is called the
45° triangle.
Triangles can be used as a straightedge to connect
points for drawing lines. Triangles are used individually
or in combination to draw angled lines in 15° increments (see Figure 3-9). Also available are adjustable
triangles with built-in protractors that are used to make
Templates are plastic sheets with standard symbols cut
through them for tracing. There are as many standard
architectural templates as there are architectural symbols to draw. Templates are commonly scaled to match
a specific application, such as floor plan symbols.
One of the most common architectural templates
used is the residential floor plan template shown in
Figure 3-10. This template is typically available at a
scale of 1/4" = 1'−0" (1:50 metric), which matches the
scale usually used for residential floor plans. Features
that are often found on a floor plan template include
circles, door swings, sinks, bathroom fixtures, kitchen
appliances, and electrical symbols. Other floor plan
templates are available for both residential and commercial applications. Additional architectural templates are
introduced in chapters where their specific applications
are discussed.
Always use a template when you can. For instance,
use a circle template rather than a compass when possible. Templates save time, are very accurate, and help
standardize features on drawings. For most applications the template should be used only after the layout
has been created. For example, floor plan symbols are
placed on the drawing after walls, openings, and other
main floor plan features have been established.
When using a template, carefully align the desired
template feature with the layout lines of the drawing.
Hold the template firmly in position while you draw the
feature. For best results, try to keep your pencil or pen
perpendicular to the drawing surface.
Template Use with Technical Pens
45°
30°
60°
15°
75°
90°
FIGURE 39 Angles that can be made with the 30°–60° triangle
and 45º triangle, individually or in combination.
Information on using a template and a technical pen is included on the Student CD.
FIGURE 310 Architectural floor plan symbol template.
Courtesy Berol Corporation.
50
Architectural Drafting and Design
FIGURE 312 Arm drafting machine. Courtesy VEMCO America, Inc.
FIGURE 311 Irregular or French curves. Courtesy of C-Thru® Ruler
Company.
Irregular Curves
Irregular curves are commonly called French curves.
Irregular curves are used to draw arcs having no constant radii. A selection of irregular curves is shown in
Figure 3-11. Also available are ship’s curves, which
become progressively larger and also have no constant
radii. Ship’s curves are used for layout and development
of ships’ hulls. Flexible curves are made of plastic and
have a flexible core. They can be bent and shaped to
draw almost any desired curve.
Irregular curves are used for a variety of applications
in architectural drafting. Some drafters use the curves to
draw floor plan electrical runs or leader lines that connect notes to features on the drawing.
DRAFTING MACHINES
Drafting machines can be used in place of triangles and
parallel bars. Drafting machines have scales attached vertically and horizontally, which are used as straightedges
and for measuring increments on a drawing. The drafting machine maintains a 90º relationship between scales
using a protractor mechanism. The protractor allows the
scales to be set quickly at any angle. There are two types
of drafting machines: arm and track. Although both
types are excellent tools, the track machine has advantages over the arm machine in industry. A major advantage of the track machine is it allows you to work with a
board in the vertical position. A vertical drafting surface
position is generally more comfortable to use than a horizontal table. For school or home use, the arm machine
can be a good economical choice. When you order a
drafting machine, the size specified should relate to the
size of the drafting table. For example, a 37 1/2 × 60"
machine fits the same size table.
Arm Drafting Machine
The arm drafting machine is compact and less expensive than a track machine. The arm machine clamps
to a table and through an elbow-like arrangement of
supports allows you to position the protractor head
and scales anywhere on the board. The arm drafting
machine is shown in Figure 3-12.
Track Drafting Machine
A track drafting machine has a traversing arm that
moves left and right across the table, and a head unit
that moves up and down the traversing arm. There is
a locking device for both the head and the traversing
arm. The shape and placement of the controls of a
track machine vary with the manufacturer, although
most brands have the same operating features and procedures. Figure 3-13 shows the component parts of a
track drafting machine.
As with the arm machines, track drafting machines
have a vernier scale head that allows you to measure
VERTICAL TRACK BRACKET
CLAMP
HORIZONTAL TRACK
VERTICAL BRAKE LEVER
VERTICAL TRACK
HORIZONTAL
BRAKE LEVER
DOUBLE HINGE
VERTICAL SCALE
HORIZONTAL SCALE
SCALE CHUCK
PLATE
SCALE CHUCK ARM
MICRO ADJUSTMENT
ANGLE-SETTING CLAMP
BASE-LINE CLAMP
FOOT ROLLER
FIGURE 313 Track drafting machine and its parts. Courtesy
Mutoh America, Inc.
Chapter 3: Architectural Drafting Equipment
51
angles accurately to 5 minutes of arc (5'). A vernier scale
is an auxiliary scale sliding alongside a main scale to
allow reading of fractional values during measurement.
There are 360 degrees in a circle. One degree equals
60 minutes (1° = 60'), and 1 minute equals 60 seconds
(1' = 60").
DRAFTING MACHINE
CONTROLS AND MACHINE
HEAD OPERATION
that given in the title block. Drawings are scaled so
that the object represented can be illustrated clearly on
standard sheet sizes. It would be difficult, for example,
to draw a full-size house, so a scale is used to reduce the
size of such large objects. Drawing title blocks and sheet
sizes are discussed in Chapter 4.
The drawing scale selected depends on:
●
The drafting machine head contains controls for horizontal, vertical, and angular movement. Refer to the
Student CD: DRAFTING MACHINE CONTROLS AND
MACHINE HEAD OPERATION for more information.
Actual size of the structure.
Amount of detail to be shown.
● Sheet size selected.
● Amount of dimensions and notes required.
● Common standard practice that regulates the scale of
specific drawing types.
SCALES
The following scales and their notation are frequently
used on architectural drawings.
The drafting instruments used for making measurements, establishing dimensions, and drawing features at
reduced size are called scales. Architectural drafting scales
are available in a variety of shapes and calibrations.
Scale Shapes
There are four basic scale shapes, which are shown
in Figure 3-14. The two-bevel scales are also available
with chuck plates for use with standard arm or track
drafting machines. These machine scales have typical
calibrations, and some have no scale reading, for use
as a straightedge alone. Drafting machine scales are
purchased by designating the length needed, such
as 12", 18", or 24", and the scale calibration, such as
metric; engineer’s full scale in tenths and half scale
in twentieths; or architect’s scale 1/4" = 1'−0" and
1/2" = 1'−0". Many other scales are also available.
The triangular scale is commonly used because it
offers many scale options and is easy to handle.
Scale Notation
The scale of a drawing is usually noted in the drawing
title block or below the view that differs in scale from
TWO
BEVEL
FOUR
BEVEL
FIGURE 314 Scale shapes.
OPPOSITE
BEVEL
TRIANGULAR
●
1/8" = 1'−0"
3/8" = 1'−0"
1 1/2" = 1'−0"
3/32" = 1'−0"
1/2" = 1'−0"
3" = 1'−0"
3/16" = 1'−0"
3/4" = 1'−0"
12" = 1'−0"
1/4" = 1'−0"
1" = 1'−0"
Some scales used in civil drafting are noted as
follows:
1" = 10'
1" = 50'
1" = 300'
1" = 20'
1" = 60'
1" = 400'
1" = 30'
1" = 100'
1" = 500'
1" = 40'
1" = 200'
1" = 600'
Metric Scale
According to the American National Standards Institute
(ANSI), the International System of Units (SI) linear unit,
which is commonly used on drawings is the millimeter.
On drawings where all dimensions are in either inches
or millimeters, individual identification of units is not
required. However, the drawing shall contain a note
stating: UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS
ARE IN INCHES (or MILLIMETERS as applicable). Where
some millimeters are shown on an inch-dimensioned
drawing, the millimeter value should be followed by
the symbol mm. Where some inches are shown on a
millimeter-dimensioned drawing, the inch value should
be followed by the abbreviation in.
Metric symbols are as follows:
millimeter = mm
dekameter = dam
centimeter = cm
hectometer = hm
decimeter = dm
kilometer = km
meter = m
52
Architectural Drafting and Design
112 mm
60 mm
1000 mm
25 mm
500 mm
I00 mm
I0 mm
20 mm
I mm
1:25
1:1
0
10
20
30
40
50
60
70
80
90
100 110 120
0
FULL SCALE = 1:1
500
1 m = 1 meter
ONE TWENTY-FIFTH SCALE = 1:25
112 mm
60 mm
800 mm
25 mm
I00 mm
I0 mm
2 mm
2 mm
1:2
0
20
40
60
80
100
120
140
160
1:33 1/3
180
50
0
HALF SCALE = 1:2
1m
ONE THIRTY-THREE AND ONE-THIRD SCALE = 1:33 1/3
280 mm
1800 mm
112 mm
1000 mm
60 mm
I00 mm
I0 mm
5 mm
50 mm
1:5
0
100
200
1:75
300
0
ONE-FIFTH SCALE = 1:5
1m
ONE SEVENTY-FIFTH SCALE = 1:75
METRIC SCALES THAT MATCH ARCHITECT AND CIVIL SCALES
Metric Scales
Inch-to-Feet Architectural Scales
Civil Engineering Scales
1:1
FULL SCALE, 1:1
1:5
Close to 3" = 1'–0"
1:10
Between 1" = 1'–0" and 1 1/2" = 1'–0"
1:20
Between 1/2 " = 1'–0" and 3/4" = 1'–0"
1:50
Close to 1/4 " = 1'–0"
1:100
Close to 1/8" = 1'–0"
1:200
Close to 1/16 " = 1'–0"
1:500
Close to 1" = 40'
1:1000
Close to 1" = 80'
FIGURE 315 Common metric scale calibrations and measurements.
Some metric-to-metric equivalents are provided in
the following:
10 millimeters = 1 centimeter
10 centimeters = 1 decimeter
10 decimeters = 1 meter
10 meters = 1 dekameter
10 dekameters = 1 kilometer
Some metric-to-U.S. customary equivalents are provided in the following:
1 millimeter = 0.03937 inch
1 centimeter = 0.3937 inch
1 meter = 39.37 inches
1 kilometer = 0.6214 mile
Chapter 3: Architectural Drafting Equipment
53
Some U.S. customary-to-metric equivalents are provided in the following:
1/16
1 mile = 1.6093 kilometers = 1609.3 meters
1 yard = 914.4 millimeters = 0.9144 meter
1 foot = 304.8 millimeters = 0.3048 meter
1 inch = 25.4 millimeters = 0.0254 meter
1/32
1/64
16
To convert inches to millimeters, multiply inches
by 25.4.
One advantage of metric scales is any scale is a multiple of 10. Therefore, reductions and enlargements
are easily performed. In most cases, no mathematical
calculations are required when using a metric scale.
Whenever possible, select a direct reading scale. If no
direct reading scale is available, use multiples of other
scales. To avoid the possibility of error, avoid multiplying or dividing metric scales by anything other than
multiples of 10. Some metric scale calibrations are
shown in Figure 3-15.
FIGURE 317 Enlarged view of an architect’s 16 scale.
●
Floor plans for most residential structures are drawn
at 1/4" = 1'−0".
Architect’s Scale
●
Although some applications require a larger or smaller
scale, commercial buildings are often drawn at 1/8" =
1'−0" when they are too large to be drawn at the same
scale as a residence.
●
Exterior elevations are commonly drawn at 1/4" =
1'−0", although some architects prefer to draw the
front, or most important, elevation at 1/4" = 1'−0"
and the rest of the elevations at 1/8" = 1'−0".
●
Construction details and cross sections can be drawn
at larger scales to help clarify specific features. Some
cross sections can be drawn at 1/4" = 1'−0" with
clarity, but complex cross sections require a scale of
3/8" = 1'−0" or 1/2" = 1'−0" to be clear.
●
Construction details can be drawn at any scale
between 1/2" = 1'−0" and 3" = 1'−0", depending
on the amount of information presented.
The triangular architect’s scale contains 11 different
scales. On 10 of the scales, each inch represents a foot
and is subdivided into multiples of 12 parts to represent
inches and fractions of an inch. The 11th scale is the
full scale with a 16 in the margin. The 16 means that
each inch is divided into 16 parts, and each part is equal
to 1/16 inch. Figure 3-16 shows an example of the full
architect’s 16 scale. Figure 3-17 shows the fraction calibrations of the full architect’s 16 scale.
Look at the architect’s scale examples in Figure 3-18.
Notice the form in which scales are expressed on a drawing. The scale is expressed as an equation of the drawing size in inches or fractions of an inch to 1 foot. For
example: 3" = 1'−0", 1/2" = 1'−0", or 1/4" = 1'−0".
The architect’s scale commonly has scales running in
both directions along an edge. When reading a scale
from left to right, be careful not to confuse its calibrations with the scale that reads from right to left.
When selecting scales for preparing a set of architectural drawings, several factors must be considered.
2 17/32
1 3/16
1/2
16
0
1
2
FIGURE 316 Full (1:1), or 12" = 1'−0", architect’s scale.
3
1/8
1/4
1/2
Some parts of a set of drawings are traditionally drawn
at a certain scale, for example:
Civil Engineer’s Scale
The architectural drafter also commonly uses the civil
engineer’s scale to draw site plans, maps, or subdivision
plats or to read existing land documents. Most landrelated plans such as construction site plans are drawn
using the civil engineer’s scale, although some are drawn
with an architect’s scale. Common architect’s scales
used for site plans are 1/8" = 1'−0", 3/32" = 1'−0", and
1/16" = 1'−0". Common civil engineer’s scales used for
site plans are 1" = 10', 1" = 50', and 1" = 100'. The triangular civil engineer’s scale contains six scales, one on
each of its sides. The civil engineer’s scales are calibrated
in multiples of ten. The scale margin specifies the scale
54
Architectural Drafting and Design
2 11/16
1/8
1/16
16
0
1
2
3
11
12
FULL SIZE; 1:1 ; 12"= 1'–0"
1
1
8 1/2
1/4
9
1 1/2
6
3
0
0
3
1/8 SIZE; 1 1/2" = 1'–0"
1/4
1/8
8 1/2
6
1/4 SIZE; 3" = 1'–0"
6
9
3
20
0
1/2
3'–5"
1'–7 1/2"
1
3
9
8
1
4
1/24 SIZE; 1/2" = 1'–0"
1
—
1/2"
2
0
2
9
10
1/12 SIZE; 1" = 1'–0"
1/2
1
5'–4"
3/8
0
2
14
2'–7 1/2"
4
13
12
6
2
26
28
1
3/4
0
1/16 SIZE; 3/4" = 1'–0"
1/32 SIZE; 3/8" = 1'–0"
1
2
18'–4"
1/8 0
46
8
42
4
44
1/8
5'–3"
12
40
16
38
20
36
76
8
80
6
84
88
4
92
0
2
1/4
1/4
1/48 SIZE; 1/4" = 1'–0"
1/96 SIZE; 1/8" = 1'–0"
1
2
11'–4"
23'–0"
3/32 0
62
3/32
0
4
8
12
16
20
24
28
60
58
56
54
52
50
48
1/128 SIZE; 3/32" = 1'–0"
4
12
10
8
8
12
16
20
24
6
4
2
0
1/64 SIZE; 3/16" = 1'–0"
3/16
3/16
FIGURE 318 Architect’s scale combinations.
represented on a specific edge. Keep in mind that any
multiple of 10 is available with this scale.
The 10 scale is used in civil drafting for scales such as
1" = 10', 1" = 100', and 1" = 1000'. Any multiple of 10
can be used (see Figure 3-19). The 20 scale is used for
scales such as 1" = 2', 1" = 20', or 1" = 200'.
The remaining scales on the civil engineer’s scale are
used in a similar manner. The 50 scale is popular in civil
drafting for drawing plats of subdivisions, for example.
Figure 3-20 shows commonly used civil engineer’s
scales, with sample measurements provided.
PROTRACTORS
A protractor can be used when a drafting machine is
not used or when combining triangles does not provide
enough flexibility for drawing angles. Protractors can be
used to measure angles to within 1/2°.
Chapter 3: Architectural Drafting Equipment
55
4450'
1" = 1000'
Division
Ratio
Scales Used with This Division
10
20
1:1
1:2
1" = 1"
1" = 2"
1" = 1'
1" = 2'
1" = 10'
1" = 20'
1" = 100'
1" = 200'
30
1:3
1" = 3"
1" = 3'
1" = 30'
1" = 300'
40
50
1:4
1:5
1" = 4"
1" = 5"
1" = 4'
1" = 5'
1" = 40'
1" = 50'
1" = 400'
1" = 500'
60
1:6
1" = 6"
1" = 6'
1" = 60'
1" = 600'
235'
1" = 100'
17'
1" = 10'
10'
1" = 10'
10
0
1
2
3
4
5
FIGURE 319 Civil engineer’s scale, units of 10.
285'
1" = 100'
570'
1" = 200'
23'
1" = 10'
35'
1" = 20'
1.6'
1" = 1'
1.2
1:1
2'
1" = 2'
.10
1:1
.10
1:2
10
20
0
1
2
3
0
1
2
1"
1"
10 SCALE
20 SCALE
6900'
1" = 3000'
3
4
5
6
6
8
10
12
7400'
1" = 4000'
550'
1" = 300'
660'
1" = 400'
45'
1" = 30'
53'
1" = 40'
3'
1" = 3'
4'
1" = 4'
.10
1:3
.10
1:4
40
30
0
2
4
6
8
10
0
2
4
1"
1"
30 SCALE
40 SCALE
8300'
1" = 5000'
13600'
1" = 6000'
770'
1" = 500'
1130'
1" = 600'
64'
1" = 50'
88'
1" = 60'
5'
1" = 5'
6'
1" = 6'
.10
1:5
.10
1:6
50
60
0
2
4
6
8
10
12
14
0
2
4
1"
1"
50 SCALE
60 SCALE
FIGURE 320 Civil engineer’s scales and sample measurements at different scales.
6
8
10
12
14
16
18
56
Architectural Drafting and Design
CADD APPLICATIONS
As a professional drafter, designer, or architect, you
may continue to see the traditional manual drafting
equipment in some offices. However, drafting has
changed. The concepts and theories are the same, but
the tools are different. Traditional manual drafting
has been converting to computer-aided design and
drafting (CADD). Computer-aided design and drafting
is common in architectural drafting schools and
architectural businesses. The CADD workstation is
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you find information related to drafting supplies
and equipment.
Address
www.alvinco.com
www.vemcocorp.com
different from the traditional manual drafting table
and equipment described throughout this chapter.
Drafting tools have changed. For example, the new
table is flat and holds a computer, monitor, keyboard,
and mouse. A printer and a plotter are usually on
or available to the workstation. Chapter 7 describes
the computer-aided drafting workstation in detail
and explains computer-aided design and drafting
applications. ■
Company, Product,
or Service
Drafting equipment and
tables
Drafting machines
Drafting pencils
www.mayline.com
Drafting tables
For additional Web sites, search for these key words on your
Web browser.
Drafting pencils, supplies,
tables, machines, templates
www.pentel.com
Architectural Drafting Equipment Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
Question 3–5 In a short, complete paragraph, describe
how to properly use a mechanical pencil.
1. Letter your name, Chapter 3 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 3–7 List three characteristics recommended
for technical pen inks. Refer to the Student CD:
Supplemental Reference: TECHNICAL PENS AND
ACCESSORIES.
Question 3–1 Describe a mechanical drafting pencil.
Question 3–2 Describe an automatic drafting pencil.
Question 3–3 List three lead sizes available for
automatic pencils.
Question 3–4 Identify how graphite leads are labeled.
Question 3–6 In a short, complete paragraph, describe
how to properly use an automatic pencil.
Question 3–8 Describe one advantage and one disadvantage of using an electric eraser.
Question 3–9 What type of compass is most commonly
used by professional drafters?
Question 3–10 Why should templates be used whenever
possible?
Chapter 3: Architectural Drafting Equipment
57
Question 3–11 Why should a compass point with a
shoulder be used when possible?
Question 3–30 Name the scale shape that is commonly
used, and why.
Question 3–12 Identify two lead points that are
commonly used in compasses.
Question 3–31 To convert inches to millimeters,
multiply inches by _____.
Question 3–13 What is the advantage of placing drafting
tape or plastic at the center of a circle before using a
compass?
Question 3–32 What is an advantage of using metric
scales?
Question 3–14 A good divider should not be too loose
or too tight. Why?
PROBLEMS
Question 3–15 What are two uses for dividers?
Question 3–16 At what number of degree increments do
most drafting machine heads automatically lock?
Question 3–17 How many minutes are there in 1°? How
many seconds in 1'?
Question 3–18 Explain the uses of and differences
between the soft-green and soft-pink erasers.
Question 3–19 What type of eraser is recommended for
use on polyester drafting film?
Question 3–20 Provide a short, complete paragraph
explaining the proper erasing technique.
Question 3–21 Name at least five features found on a
residential floor plan template.
Question 3–22 What piece of drafting equipment is
used to draw curves that have no constant radii?
Question 3–23 Describe the parallel bar and how it
is used.
Question 3–24 Why is the parallel bar commonly used
for manual drafting in the architectural office?
Question 3–25 In combination, the 30° to 60° triangle
and the 45° triangle may be used to make what range
of angles?
Question 3–26 Show how the following scales are
noted on an architectural drawing: 1/8", 1/4", 1/2",
3/4", 1 1/2", and 3".
Question 3–27 What civil engineer’s scale is commonly
used for subdivision plats?
Question 3–28 What architectural scale is usually used
for drawing residential floor plans?
Question 3–29 List three factors that influence the
selection of a scale for a drawing.
Determine the length of the following lines using an architect’s
scale, a civil engineer’s scale, and a metric scale. The scales to
use when measuring are given above each line. The architect’s
scale is first; the civil engineer’s scale is second; and the metric
scale is third.
Problem 3–1 a. Scale: 1/8" = 1'−0"
b. 1" = 10'−0"
c. 1:1 (metric)
Problem 3–2 a. Scale: 1/4" = 1'−0"
b. 1" = 20'−0"
c. 1:2 (metric)
Problem 3–3 a. Scale: 3/8" = 1'−0"
b. 1" = 30'−0"
c. 1:5 (metric)
Problem 3–4 a. Scale: 1/2" = 1'−0"
b. 1" = 40'−0"
c. 1:10 (metric)
Problem 3–5 a. Scale: 3/4" = 1'−0"
b. 1" = 50'−0"
c. 1:20 (metric)
Problem 3–6 a. Scale: 1" = 1'−0"
b. 1" = 60'−0"
c. 1:50 (metric)
Problem 3–7 a. Scale: 1 1/2" = 1'−0"
b. 1" = 100"
c. 1:75 (metric)
Problem 3–8 a. Scale: 3" = 1'−0"
b. 1" = 200'
c. 1:75 (metric)
CHAPTER 4
Drafting Media and
Reproduction Methods
I
N
T
R
O
D
U
C
T
I
O
N
This chapter covers the types of media used for the drafting and the reproduction of architectural drawings. Manual
drawings are generally prepared on precut drafting sheets
with printed graphic designs for the company logo and
information, borders, and title blocks. Computer-aided
drawings are generally created using a template containing
a border, title block, and graphic designs for the company.
The computer-aided drawings are stored in files and reproduced on media by printing or plotting. This is described
in Chapter 7. Drawing reproductions or copies are made
for use in the construction process so the original manual
drawings are not damaged. Alternative materials and reproduction methods are described as they relate to common
architectural practices.
PAPERS AND FILMS
A variety of paper and plastic media, known as
film, has been used for manual drafting applications.
Computer-aided drawings can be printed on the same
media used for most manual drafting applications, but
are generally printed on materials better suited for
computer printing methods.
Selection of Drafting Media
This discussion relates to the selection of media for
manual drafting applications. The selection of these
media can also apply to CADD, but other factors are
also described for these applications.
Several factors influence the choice and use of
manual drafting media. These include durability,
smoothness, erasability, dimensional stability, transparency, and cost.
●
58
Durability should be considered if the original drawing is expected to have a great deal of use. Originals
can tear or wrinkle, and the images become difficult
to see if the drawings are used often.
●
Smoothness relates to how the medium accepts line
work and lettering. The material should be easy to
draw on, so the image is dark and sharp without
excessive effort on the part of the drafter.
● Erasability is important because errors need to be
corrected and changes are made frequently. When
images are erased, ghosting should be kept to a
minimum. Ghosting is the residue when lines are
not completely removed. These unsightly ghost
images can reproduce in a print. Materials with
good erasability are easy to clean.
● Dimensional stability is the quality of the medium
that maintains size despite the effects of atmospheric conditions such as heat and cold. Some materials are more dimensionally stable than others.
● Transparency is one of the most important characteristics of drawing media. The diazo reproduction
method requires light to pass through the material. Diazo printing is not commonly used today,
and is described on the Student CD. The final
goal of a drawing is good reproduction, so the
more transparent the material is, the better the
reproduction, assuming that the image drawn is of
professional quality. Transparency is not a factor
with photocopying.
● Cost can influence the selection of drafting media.
When the best reproduction, durability, smoothness,
erasability, and dimensional stability are important,
there may be few cost alternatives. If drawings are to
have normal use and reproduction quality, then the
cost of the drafting media can be kept to a minimum.
The following discussion of available materials can
help you evaluate cost differences.
Vellum
Vellum is drafting paper that is specially designed
to accept pencil or ink. Lead on vellum is the most
common combination used for manual drafting.
Chapter 4: Drafting Media and Reproduction Methods
Vellum is the least expensive material and has good
smoothness and transparency. Use vellum originals
with care. Drawings made on vellum that require a
great deal of use could deteriorate. Vellum is not as
durable as other materials. Also, some brands are more
erasable than others. Affected by humidity and other
atmospheric conditions, vellum generally is not as
dimensionally stable as other materials.
Polyester Film
Polyester film, also known by its trade name
Mylar, is a plastic manual drafting material that
is more expensive than vellum but offers excellent durability, erasability, dimensional stability,
and transparency. Drawing on polyester film is
best accomplished using ink or special polyester
leads. Do not use regular graphite leads, because
they smear easily and do not adhere properly to
the surface. Drawing techniques that drafters use
with polyester leads are similar to those used with
graphite leads except that polyester lead is softer
and feels like a crayon.
Film is available with a single- or double-matte
surface. Matte is a surface texture that is not glossy.
Manual drafting is done on the matte surface.
Double-matte film has texture on both sides so
drawing can be done on either side if necessary.
Single-matte film, which is more common, has a
matte surface on one side and a slick surface on the
other side. When using polyester film, be very careful not to damage the matte by erasing. Erase at right
angles to the direction of your lines, and do not use
too much pressure. This helps minimize damage to
the matte surface. Once the matte is removed, the
surface does not accept ink or pencil. Also, be careful not to get moisture on the polyester film surface.
Moisture or grease from your hands can cause ink to
skip across the material.
Normal handling of drawing film is bound to soil
it. Inked lines applied over soiled areas do not adhere
well and in time can chip off or flake. It is always
good practice to keep the film clean. Soiled areas can
be cleaned effectively with special film cleaner.
MANUAL DRAWING REPRODUCTION
The one thing most engineers, architects, designers,
and drafters have in common is that their finished
drawings are made to be reproduced. The goal of
59
every professional is to produce drawings of the
highest quality, providing the best possible prints
when reproduced.
Reproduction is the most important factor in the
selection of media for drafting. The primary combination that achieves the best reproduction is the
blackest, most opaque lines or images on the most
transparent base or material. Each of the materials described makes good prints if the drawing is
created with clean, sharp, and opaque lines and
lettering. Some products have better characteristics
than others for quality reproduction. It is up to the
individual or company to determine the combination that works best for the purpose and budget.
The question of reproduction is especially important
when sepias must be made. Sepias are second- or
third-generation originals. For more information on
sepias, see the Student CD: Supplemental Reference:
DIAZO REPRODUCTION.
Figure 4-1 shows a magnified view of graphite on
vellum, plastic lead on polyester film, and ink on
polyester film. Notice that each combination provides progressively improved reproduction quality.
As you can see from the figure, the best reproduction is achieved with a crisp, opaque image on
transparent material. If your original drawing is not
of good quality, it will not get better on the print.
Even though graphite on vellum is shown as the
lowest quality combination for quality reproduction, this combination is the most commonly used
for manual drafting practice. The use of graphite
on vellum is generally considered the easiest and
fastest combination for use in professional manual
drafting. Quality originals are created using graphite on vellum when professional drafters follow
proper techniques.
GOOD
BETTER
BEST
GRAPHITE
ON VELLUM
PLASTIC LEAD
ON MYLAR
DIRECT INK
DRAFTING
ON MYLAR
FIGURE 41 A magnified comparison of graphite on
vellum, plastic lead on Mylar, and ink on Mylar. Courtesy
Koh-I-Noor, Inc.
60
Architectural Drafting and Design
CADD APPLICATIONS
Drafting Archives
CADD has almost entirely taken over manual drafting in
architecture and industry. Some companies and individuals
hold on to traditional drafting practices. Many have said
that professional manual drafting is an art form made up
of line styles, contrasting line thicknesses, and lettering.
Manual architectural lettering is an art style of its own.
While there are similarities in the style of architectural
lettering, the artistic presentation follows examples
provided in Chapter 6. Preserving this artistic lettering
style is so important that CADD programs have text styles
closely duplicating the best architectural hand lettering.
For a time into the near future, there may be a need
for you to create new manual drawings or revise archive
SHEET SIZES, SHEET FORMAT, TITLE
BLOCKS, AND BORDERS
Every professional drawing has a title block. Standards
have been developed for the information put into the
title block and on the sheet next to the border. A standardized drawing is easier to read and file than drawings
that do not follow a standard format. The term file, as it
relates to manual drafting, is the storage of drawings in
standard file cabinets.
Sheet Sizes
Drafting materials are available in standard sizes, which
are determined by manufacturers’ specifications and
based on national standards. Paper and polyester film
can be purchased in cut sheets or in rolls. Architectural
drafting offices generally use cut sheet sizes, in inches,
of 18 × 24, 24 × 36, 28 × 42, 30 × 42, 30 × 48, or
36 × 48. Roll sizes vary in width from 18" to 48".
Sheet sizes used in architectural drafting are often
different, but can be the same as sheet sizes recommended by the American National Standards Institute
(ANSI) for mechanical drafting done for manufacturing. ANSI sheet sizes, title block format, and content
follow a strict set of standards for use in the industry.
Architectural sheets, title block format, and content
do not generally follow the same strict standards. The
actual application depends on the practice followed
drawings. The term archive defines old drawings that are
no longer in use and are stored for possible future use or
reference. When revising archive drawings, handle the
original very carefully to avoid causing damage. Use
the same medium, such as graphite, used on the original
drawing. Try to carefully match the line and lettering
style used on the original. Reproduce the original as
needed and carefully store the original in its proper
archive location when finished.
Many companies have converted or are continuing
to convert their manual drawings to computer-aided
drawings. ■
Sheet Size
Dimensions (inches)
A
8 1/2 × 11 or 11 × 8 1/2
B
17 × 11
C
22 × 17
D
34 × 22
E
44 × 34
F
40 × 28
TABLE 41 Standard ANSI Inch Drawing Sheet Sizes
in a specific architectural office. Table 4-1 shows the
standard ANSI-recommended inch sheet sizes.
Metric sheet sizes vary from 297 × 210 mm to
1189 × 841 mm. Metric roll sizes range from 297 mm
to 420 mm wide. The International Organization for
Standardization (ISO) has established standard metric
drawing sheet sizes that have been adopted by ANSI.
Standard metric drawing sheet sizes are shown in
Table 4-2.
Sheet Size
Dimensions
(mm)
Dimensions
(inches)
A0
1189 × 841
46.8 × 33.1
A1
841 × 594
33.1 × 23.4
A2
594 × 420
23.4 × 16.5
A3
420 × 297
16.5 × 11.7
A4
297 × 210
11.7 × 8.3
TABLE 42 Standard Metric Drawing Sheet Sizes
Chapter 4: Drafting Media and Reproduction Methods
Zoning
Some companies use a system of numbers along the
top and bottom margins, and letters along the left and
right margins. This system is called zoning. Zoning
allows a drawing to be read like a road map. For
example, the reader can refer to the location of a specific item as D-4, which means the item can be found
on or near the intersection of row D and column 4.
Zoning can be found on some architectural drawings,
although it is more commonly used in mechanical
drafting for manufacturing.
Architectural Drafting Title Blocks
Title blocks and borders are normally preprinted
on drawing paper or polyester film for manual
drafting applications to help reduce drafting time
and cost.
“Drawing borders” are thick lines that go around
the entire sheet. Top, bottom, and right-side border
lines are usually between 3/8" and 1/2" away from
the sheet edge. The left border can be between 3/4"
and 1 1/2" away from the sheet edge. This extrawide left margin allows for binding drawing sheets.
Preprinted architectural drawing title blocks
are generally placed along the right side of the
sheet, although some companies place them across
the bottom of the sheet. Each architectural company uses a slightly different title block design, but
this same general information is found in almost
all blocks:
●
Drawing number. This can be a specific job or file
number for the drawing.
● Company name, address, and phone number.
● Project or client. This is an identification of the project by company or client, project title, or location.
● Drawing name. This is where the title of the drawing is placed. For example, MAIN FLOOR PLAN
or ELEVATIONS. Most companies leave this information off the title block and place it on the face of
the sheet below the drawing.
● Scale. Some company title blocks provide space
for the drafter to fill in the general scale of the
drawing. Any view or detail on the sheet that differs from the general scale must have the scale
identified below the view title, and both are placed
directly below the view.
61
●
Drawing or sheet identification. Each sheet is numbered in relation to the entire set of drawings. For
example, if the complete set of drawings has 8 sheets,
then consecutive sheets are numbered 1 of 8, 2 of
8, 3 of 8, through 8 of 8.
● Date. The date noted is the one on which the
drawing or project is completed.
● Drawn by. The place for the initials or name of
the drafter, designer, or architect who prepared the
drawing.
● Checked by. This is the identification of the individual who approves the drawing for release.
● Architect or designer. Most title blocks provide
for the identification of the individual who designed
the structure.
● Revisions. Many companies provide a revision
column where changes in the drawing are identified and recorded. After a set of drawings is
released for construction, there can be changes.
When this is necessary, there is usually a written
request for a change from the contractor, owner, or
architect. The change is then implemented on the
affected drawings. Where changes are made on the
face of the drawing, a circle with a revision number
accompanies the change. This revision number is
keyed to a place in the drawing title block where
the revision number, the revision date, the initials of
the individual making the change, and an optional
brief description of the revision are located. For
further record of the change, the person making
the change also fills out a form, called a change
order. The change order was discussed in Chapter 2.
The change order contains complete information
about the revision for future reference. The change
process and the method of documenting changes
vary between companies.
Figure 4-2 shows different architectural title
blocks. Notice the similarities and differences between
the title blocks.
HOW TO FOLD PRINTS
Architectural drawings are generally created on large
sheets, and prints are made from the originals. It is
necessary to fold the architectural prints properly
when they must be mailed or filed in a standard file
cabinet. Folding large prints is much like folding a
road map. Folding is done in a pattern of bends that
62
Architectural Drafting and Design
FIGURE 42 Sample architectural title blocks. (A) Courtesy Summagraphics; (B) Courtesy Southland Corporation; (C) Courtesy Structureform.
puts the title block and sheet identification on the
front. Using the proper method to fold prints also
aids in unfolding and refolding prints. Never fold
original drawings. Figure 4-3 shows how large prints
are folded.
DIAZO REPRODUCTION
The diazo reproduction method, also known
as blue-line prints, has historically been one
of the most common methods for reproducing original
manual drawings. Refer to the Student CD: DIAZO
REPRODUCTION, for more information.
PHOTOCOPY REPRODUCTION
A photocopy is a photographic reproduction of printed
or graphic material. Photocopies of architectural drawings are commonly made on large-size engineering
copy machines, also called engineering copiers or
engineering printers. The photocopy engineering-size
printer makes prints up to 36" wide and up to 25' long
from originals up to 36" wide by 25' long. Prints can be
made on bond paper, vellum, polyester film, colored
paper, or other translucent materials. Reproduction
capabilities also include reduction and enlargement
on some models. Bond paper is a strong, durable
paper especially suitable to electronic printing and
use in office machines including copiers and desktop
printers.
Almost any large original can be converted into a
smaller-sized reproducible print for distribution, inclusion in manuals, or more convenient handling. Also,
a random collection of mixed-scale drawings can be
enlarged or reduced and converted to one standard
scale and format. Reproduction clarity is so good that
halftone illustrations, photographs, and solid or fine
line work have excellent resolution and density. The
photocopy process has mostly replaced the diazo reproduction process for copying architectural drawings. A
halftone is the reproduction of continuous-tone artwork, such as a photograph, by converting the image
into dots of various sizes.
MICROFILM
Microfilm is a film containing a reduced image
of a drawing or other printed material for
compact storage and for future access, viewing, and
reproduction. Refer to the Student CD: MICROFILM,
for more information.
Chapter 4: Drafting Media and Reproduction Methods
63
FOLD 5
FOLD 4
FOLD 3
FOLD 2
FOLD 1
FOLD 5
FOLD 1
FOLD 2
FOLD 1
FOLD 2
FOLD 3
FOLD 2
FOLD 1
B-SIZE
C-SIZE
D-SIZE
E-SIZE
FIGURE 43 How to fold B-size, C-size, D-size, and E-size prints.
64
Architectural Drafting and Design
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you find information related to drafting media and
standards.
Address
www.aia.org
Company, Product,
or Service
American Institute
of Architects
www.ansi.org
American National
Standards Institute
www.clearprintpapercompany.com
Drafting paper
Drafting Media and Reproduction Methods Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
Question 4–12 Identify two different locations where
the scale can be located on an architectural drawing.
1. Letter your name, Chapter 4 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 4–14 Briefly describe the revision process and
its steps.
Question 4–13 What are the results of a properly folded
print?
Question 4–15 What is another name for a diazo
print?
Question 4–1 List five factors in the choice and use of
drafting materials.
Question 4–16 Is a diazo print the same as a blueprint?
Explain. Refer to the Student CD: Supplemental
Reference: DIAZO REPRODUCTION.
Question 4–2 Why is transparency so important in
reproducing copies using the diazo process? Refer
to the Student CD: Supplemental Reference: DIAZO
REPRODUCTION.
Question 4–17 Describe the diazo process. Refer to
the Student CD: Supplemental Reference: DIAZO
REPRODUCTION.
Question 4–3 Describe vellum.
Question 4–4 Describe polyester film.
Question 4–5 What is another name for polyester film?
Question 4–6 Define matte, and describe the difference
between single-matte and double-matte.
Question 4–7 Which of the following combinations
yields the best reproduction: graphite on vellum,
plastic lead on polyester film, or ink on polyester film?
Question 4–8 What are the primary elements that give
the best reproduction?
Question 4–9 Identify three standard sheet sizes
commonly used by architectural offices.
Question 4–10 Describe zoning.
Question 4–11 What six elements are normally found in
a standard architectural title block?
Question 4–18 What should a good-quality diazo print
look like? Refer to the Student CD: Supplemental
Reference: DIAZO REPRODUCTION.
Question 4–19 Define sepias and describe their use.
Refer to the Student CD: Supplemental Reference:
DIAZO REPRODUCTION.
Question 4–20 Discuss safety precautions in the
handling of ammonia. Refer to the Student CD:
Supplemental Reference: DIAZO REPRODUCTION.
Question 4–21 Describe the recommended first-aid for
the following accidents: ammonia spilled on the skin,
ammonia in the eyes, and inhaling excess ammonia
vapor. Refer to the Student CD: Supplemental
Reference: DIAZO REPRODUCTION.
Question 4–22 List four advantages of photocopying
over the diazo process. Refer to the Student CD:
Supplemental Reference: DIAZO REPRODUCTION.
Chapter 4: Drafting Media and Reproduction Methods
65
Question 4–23 Give at least two reasons for using
microfilm. Refer to the Student CD: Supplemental
Reference: MICROFILM.
Question 4–25 Why is CADD rapidly replacing the need
for microfilm? Refer to the Student CD: Supplemental
Reference: MICROFILM.
Question 4–24 What is the big advantage of microfilm?
Refer to the Student CD: Supplemental Reference:
MICROFILM.
Question 4–26 Given the architectural title block
shown in the illustration for this question, identify
elements a through h.
h.
g.
f.
e.
d.
c.
b.
BLKID
SODERSTROM ARCHITECTS, P.C.
ARCHITECTURE PLANNING SPECIALIZED STUDIES
1200NW FRONT SUITE 410 PORTLAND, OR 97209 (503) 228-5617
a.
CHAPTER 5
Sketching Applications
I
N
T
R
O
D
U
C
T
I
O
N
Sketching, or freehand drawing, is drawing without the aid
of drafting equipment. Sketching is convenient because only
paper, pencil, and an eraser are needed. There are a number
of advantages to freehand sketching. Sketching is fast, visual
communication. The ability to make an accurate sketch quickly
can often be an asset when communicating with people at
work or at home. Especially for technical concepts, a sketch
can be the best form of communication. Most drafters prepare
a preliminary sketch to help organize thoughts and minimize
errors on the final drawing. The computer-aided drafter usually
prepares a sketch on graph paper to help establish the coordinates for drawing objects or just to organize the drawing before
beginning. Some architects, designers, and drafters use sketches
to help record the stages of progress until a final design is ready
for formal drawings.
SKETCHING TOOLS AND MATERIALS
The pencil used for sketching should have a soft lead.
A common No. 2 pencil works fine for most people.
A mechanical pencil with a soft lead such as H, F, or
HB is good. An automatic 0.7-mm or 0.9-mm pencil
with F or HB lead is also good, and commonly used
because of its availability and ease of use. Soft pencil
leads allow for maximum control and variation of
line weight. The pencil lead should not be sharp.
A slightly rounded pencil point is best because it
is easy to control and does not break easily. The
lead point is not a factor when using an automatic
pencil. Different thicknesses of line, if needed, can be
drawn by changing the amount of pressure applied
to the pencil. Paper quality is not critical, either. A
good sketching paper is newsprint, although almost
any kind of paper works. Use commonly available
paper such as standard copy machine bond paper
or notebook paper. Paper with a surface that is not
too smooth is best. Many preliminary architectural
designs have been created on a napkin at a lunch
table. Sketching paper should not be taped down
to the table. The best sketches are made when you
are able to move the paper to the most comfortable
drawing position. Some people make horizontal lines
66
better than vertical lines. If this is your situation,
move the paper so vertical lines become horizontal.
Such movement of the paper may not always be possible, so it does not hurt to keep practicing all forms
of lines for the best results.
SKETCHING STRAIGHT LINES
Lines should be sketched lightly in short, connected
segments, as shown in Figure 5-1. If you sketch one
long stroke in one continuous movement, your arm
tends to make the line curved rather than straight. If
you make a dark line, you may have to erase it if you
make an error. If you draw a light line, there is often
no need to erase an error because it does not show up
very much when the final lines are darkened to your
satisfaction.
Use the following procedure to sketch a horizontal
straight line with the dot-to-dot method:
STEP 1 Mark the starting and ending positions or dots,
as in Figure 5-2. The letters A and B are only for
instruction. All you need are the points.
STEP 2 Without actually touching the paper with the
pencil point, make a few trial motions between
the marked points to adjust your eye and hand to
the anticipated line.
SHORT 2"–3" STROKES
MAKE STROKES
FROM LEFT TO
RIGHT AND
BOTTOM TO TOP
IF RIGHT-HANDED
DOT-TO-DOT
FIGURE 51 Sketching short line segments.
A
FIGURE 52 Step 1: Dot-to-dot.
B
Chapter 5: Sketching Applications
67
A
B
FOR A Ø 6" CIRCLE
FIGURE 53 Step 3: Short, light strokes.
3" R
1
A
A
B
B
FIGURE 54 Step 4: Darken to finish the line.
1/2"–1" WIDE
STEP 3 Sketch very light lines between the points by
moving the pencil in short, light strokes, 2" to
3" long. With each stroke, attempt to correct the
most obvious defects of the preceding stroke so
the finished light lines are relatively straight (see
Figure 5-3).
STEP 4 Darken the finished line with a dark, distinct,
uniform line directly on top of the light line. Usually
the darkness can be obtained by pressing on the
pencil (see Figure 5-4).
FIGURE 56 Step 1: Making a trammel.
2
CENTER
A
B
FIGURE 57 Step 2: Marking the radius with a trammel.
SKETCHING CIRCULAR LINES
The parts of a circle are shown in Figure 5-5. Three
sketching techniques are used in making a circle: trammel, hand compass, and nail and string.
Sketching Circles Using the Trammel
Method
A trammel is an instrument used for making circles. In
this example, the instrument is a strip of paper. Use the
following steps to sketch a 6" diameter circle using the
trammel method:
STEP 1 To sketch a 6" diameter circle, tear or cut a
strip of paper approximately 1" wide and longer
than the radius of 3". On the strip of paper, mark an
approximate 3" radius with tick marks, such as A and
B in Figure 5-6.
STEP 2 Sketch a straight line representing the diameter at the place where the circle is to be located.
On the sketched line, locate with a dot the center
of the circle. Use the marks on the trammel to
mark the other end of the radius line, as shown in
Figure 5-7. Place the trammel next to the sketched
line, being sure point B on the trammel is aligned
with the center of the circle.
STEP 3 Pivot the trammel at point B, making tick marks
at point A as you rotate the trammel, as shown in
Figure 5-8, until you have a complete circle, as
shown in Figure 5-9.
STEP 4 Lightly sketch the circumference over the tick
marks to complete the circle, as shown in Figure 5-9.
RA
CENTER
D
R IUS
X
Y
DIAMETER
Ø
C
B
Z
3
A
CIRCUMFERENCE
FIGURE 55 Parts of a circle.
FIGURE 58 Step 3: Sketching the circle with a trammel.
68
Architectural Drafting and Design
4
5
FIGURE 59 Steps 4 and 5: Completing and darkening the circle.
STEP 5 Darken the circle, as shown in Figure 5-9. You
can darken the circle directly over the tick marks if
your sketching skills are good, or if you are in a hurry.
Sketching Circles Using
the Hand-Compass Method
The hand-compass method is a quick and fairly accurate
way to sketch circles, although it takes some practice.
Use the following steps to sketch a 6" diameter circle
using the hand-compass method:
STEP 1 Be sure your paper is free to rotate completely
around 360°. Remove anything from the table that
might stop such a rotation.
STEP 2 To use your hand and a pencil as a compass, place the pencil in your hand between your
thumb and the upper part of your index finger so
your index finger becomes the compass point and
the pencil becomes the compass lead. The other
end of the pencil rests in your palm, as shown in
Figure 5-10.
FIGURE 511 Steps 4 and 5: Sketching a circle with the handcompass method.
STEP 3 Determine the approximate radius by adjust-
ing the distance between your index finger and
the pencil point. Now, with the radius established,
place your index finger on the paper at the proposed center of the circle.
STEP 4 Using the established radius, keep your hand
and pencil point in one place while you rotate the
paper with your other hand. Try to keep the radius
steady as you rotate the paper (see Figure 5-11).
STEP 5 You can perform Step 4 very lightly and then go
back and darken the circle or, if you have had a lot
of practice, you may be able to draw a dark circle as
you go (see Figure 5-11).
Sketching Circles Using
the Nail-and-String Method
A method used to sketch large circles is to tie a pencil
and a nail together with a string. The distance between
the pencil and nail is the radius of the circle. When a
large circle is to be sketched, use this method because
the other methods do not work as well. This method
is used with a nail driven at the center and a string
connected to a pencil, for drawing large circles at a
construction site.
MEASUREMENT LINES
AND PROPORTIONS
FIGURE 510 Step 2: Holding the pencil for the hand-compass
method.
In sketching an object, all the lines that make up the
object are related to each other by size and direction. In order for a sketch to communicate accurately and completely, it should be proportional to
the object. The actual size of the sketch depends on
the paper size and the desired size of the sketch. The
sketch should be large enough to be clear, but the
Chapter 5: Sketching Applications
69
LINE 1
TABLE
LINE 2
FIGURE 512 Measurement lines.
proportions of the features are more important than
the size of the sketch.
Look at the lines in Figure 5-12. How long is line 1?
How long is line 2? Answer these questions without
measuring either line; instead, relate each line to the
other. For example, line 1 can be described as half as
long as line 2, or line 2 described as twice as long as
line 1. Now you know how long each line is relative to
the other. This relationship is called proportion. You
do not know how long either line is in terms of a measured scale, but no scale is used for sketching, so this
is not a concern. Whatever line you decide to sketch
first determines the scale of the drawing, regardless of
the actual length of the line. This first line sketched
is called the measurement line. You relate all the other
lines in your sketch to the first line. This is one of the
secrets in making a sketch resemble the object being
sketched.
The second thing you must know about the relationship of the two lines in the example is their direction
and position relative to each other. Do they touch each
other? Are they parallel, perpendicular, or at some other
angle to each other? When you look at a line, ask yourself the following questions (for this example use the
two lines given in Figure 5-13):
1. How long is the second line?
Answer: Line 2 is about three times as long as line 1.
2. In what direction and position is the second line relative to the first line?
Answer: Line 2 touches the lower end of line 1 with
about a 90° angle between the lines.
Carrying this concept a step further, a third line can
relate to the first line or the second line, and additional
lines can continue to relate in the same manner. Again,
the first line drawn is the measurement line, which sets
the scale for the entire sketch.
This idea of relationship can also apply to spaces.
In Figure 5-14, the location of a table in a room can be
FIGURE 514 Spatial proportions.
determined by spatial proportions. A typical verbal location for the table in this floor plan might be as follows:
“The table is located about one-half the table width
from the top of the floor plan or about two table widths
from the bottom, and about one table width from the
right side or about three table widths from the left side
of the floor plan.”
Using Your Pencil to Establish
Measurements on a Sketch
Your pencil can be a useful tool for establishing measurements on a sketch. When you are sketching an object
that you can hold, use your pencil as a ruler. Place the
pencil next to the feature to be sketched and determine
the length by aligning the pencil tip at one end of the
feature and marking the other end on the pencil with
your thumb. The other end can also be identified by a
specific contour or mark on the pencil. Then transfer the
measurement to your sketch. The two distances are the
same. Even though sketches do not require this accuracy, this is a quick way to establish measurement lines.
A similar technique can be used to sketch a distant
object. For example, to sketch a house across the
street, hold your pencil at arm’s length and align the
pencil with a feature of the house, such as the house
width. With the pencil point at one end of the house,
place your thumb on the pencil, marking the other
end of the house. Transfer this measurement to
your sketch in the same orientation taken from the
house. Repeat this technique for all of the house features until the sketch is complete. If you keep your
pencil at arm’s length and your arm straight, each
measurement has the same accuracy and proper
proportions.
Block Technique for Sketching
MEASUREMENT
LINE
FIGURE 513 Study the relationship between the two lines.
Any illustration of an object can be surrounded overall
with a rectangle or any other geometric shapes as shown
in Figure 5-15. Before starting a sketch, visualize the
object inside a rectangle. Then use the measurement-line
70
Architectural Drafting and Design
FIGURE 517 Step 2: Block technique. Cut out the sections and
lightly sketch the shapes.
lines you learned previously. An elevation is an exterior
view of a structure, which is the house in this case. To
use the measurement-line and block techniques, follow
these steps:
FIGURE 515 Block technique.
technique with the rectangle, or block, to help determine the shape and proportions of your sketch.
Sketching Procedures Using
the Measurement-Line and Block
Techniques
You can sketch any object, such as an elevation, as you
look at an actual house or a floor plan and think about
how the features of the house relate to the measurement
STEP 1 When you start to sketch an object, try to
visualize the object surrounded with an overall
rectangle. Sketch this rectangle first with very
light lines. Sketch the rectangle in the proper proportion with the measurement-line technique, as
shown in Figure 5-16.
STEP 2 Cut sections out or away using proper proportions as measured by eye or using your pencil to
establish measurements. Use light lines, as shown in
Figure 5-17.
WIDTH
HEIGHT
WIDTH
THIS IS THE ELEVATION TO BE SKETCHED.
FIGURE 516 Step 1: Sketch the block.
THIS RECTANGLE IS IMPORTANT, ESTABLISHED
AS OVERALL WIDTH AND HEIGHT OF VIEW.
USE CONSTRUCTION LINES.
Chapter 5: Sketching Applications
71
FIGURE 521 Step 2: Evenly
spaced grid sketched over
the swimming pool.
FIGURE 522 Steps 3 and 4:
Proportioned box with a
regular grid.
FIGURE 523 Step 5: Sketching
the shape using a regular grid.
FIGURE 524 Step 6: Darkening
the object completely.
FIGURE 518 Step 3: Darken the view.
STEP 3 Complete the sketch by darkening the out-
lines desired for the finished sketch as shown in
Figure 5-18.
Sketching Irregular Shapes
By using a frame of reference or an extension of the
block method, irregular shapes can be sketched easily to
their correct proportions. Follow these steps to sketch
the free-form swimming pool shown in Figure 5-19:
STEP 1 Enclose the object in a lightly constructed box
(see Figure 5-20).
STEP 2 Sketch several evenly spaced horizontal
and vertical lines, forming a grid, as shown in
Figure 5-21. If you are sketching an object already
drawn, draw your reference lines on top of the
object lines to establish a frame of reference.
Make a photocopy, and sketch on the photocopy
if the original cannot be used. If you are sketching an object directly, you have to visualize these
reference lines on the object you sketch.
STEP 3 On your sketch, correctly locate a proportioned
box similar to the one established on the original
drawing or object, as shown in Figure 5-22.
STEP 4 Use the drawn box as a frame of reference, and
include the grid lines in correct proportion as shown
in Figure 5-22.
STEP 5 Using the grid, sketch small, irregular arcs and
lines that match the lines of the original object, as in
Figure 5-23.
STEP 6 Darken the outline for a complete proportioned
sketch, as shown in Figure 5-24.
INTRODUCTION TO MULTIVIEW
SKETCHES
FIGURE 519 Free-form
swimming pool.
FIGURE 520 Step 1:
Imaginary box.
A multiview, or multiview projection, is also known
as orthographic projection. Multiview projection
is the views of an object as projected upon two
or more picture planes in orthographic projection.
Orthographic projection is any projection of the
features of an object onto an imaginary plane called
a plane of projection, where the projection of the
object’s features is made by lines of sight that are
perpendicular to the plane of projection. These terms
72
Architectural Drafting and Design
TOP
TOP
FRONT
FRONT
RIGHT SIDE
RIGHT
SIDE
FIGURE 526 Pictorial view.
FIGURE 525 Multiviews.
are traditionally used in drafting, but they are more
commonly used in mechanical drafting for manufacturing. In architectural drafting such drawings are
referred to as elevation views. Elevation views are
two-dimensional views of an object, such as a house,
that are established by a line of sight perpendicular to
the surface of the object. When you make multiview
sketches, follow a methodical order. Learning to make
these sketches can help you later as you begin to prepare elevation drawings.
45°
Multiview Alignment
To keep your drawing in a standard form, sketch the
front view in the lower left portion of the paper, the
top view directly above the front view, and the rightside view to the right of the front view as shown in
Figure 5-25. The views needed may differ depending
on the object.
FIGURE 527 Step 1: Block out views and establish a 45° line.
Multiview Sketching Technique
The following describes how to sketch three basic views
of a house:
STEP 1 Sketch and align the proportional rectangles for
the front, top, and right side of the house given in
Figure 5-26. Sketch a 45° line to help transfer width
dimensions. The 45° line is established by projecting the width from the proposed top view location
across and the width from the proposed right-side
view location up until the lines intersect, as shown
in Figure 5-27.
STEP 2 Complete the shapes within the blocks, as shown
in Figure 5-28.
FIGURE 528 Step 2: Block out shapes.
STEP 3 Darken the lines of the object, as in Figure 5-29.
Remember to keep the views aligned for ease of
sketching and understanding by others.
Chapter 5: Sketching Applications
73
STEP 1 Sketch a horizontal reference line. You can con-
sider this as the ground-level line.
STEP 2 Sketch a vertical line perpendicular to the
ground line somewhere near its center. This vertical
line is used to measure height.
STEP 3 Sketch two 30° angular lines, each starting at
the intersection of the first two lines, as shown in
Figure 5-30.
Making an Isometric Sketch
The steps in making an isometric sketch from a multiview drawing or from a real object are as follows:
STEP 1 Select an appropriate view of the object to use as
FIGURE 529 Step 3: Darken all lines.
ISOMETRIC SKETCHES
Isometric sketches provide a three-dimensional (3D)
pictorial representation of an object, such as the shape
of a building. Isometric sketches are easy to draw and
provide a fairly realistic 3D view of an object. An isometric sketch tends to represent objects as they appear
to the eye. Such a sketch can help you visualize an
object because three sides of the object are shown in a
single three-dimensional view.
Establishing Isometric Axes
Me
asu
3rd
re
len
LIN
E
gth
of
ob
jec
ta
lon
30° APPROXIMATELY
gt
his
lin
e
2nd LINE
Measure height of object along this line
To establish isometric axes, you need four beginning
lines: a horizontal reference line, two 30° angular
lines, and one vertical line. Draw these lines as very
light construction lines as shown in Figure 5-30. Use
the following steps to establish the isometric axes:
a front view, or study the front view of the multiview
drawing.
STEP 2 Determine the best position in which to show
the object.
STEP 3 Begin your sketch by setting up the isometric
axes as previously described (see Figure 5-30).
STEP 4 Using the measurement-line technique, sketch
a rectangular box to the correct proportion, which
surrounds the object to be sketched. Use the object
shown in Figure 5-31 as an example. Imagine that
the rectangular box represents a glass box that
surrounds the object to be sketched inside. Begin
to sketch the box by marking off the width at any
convenient length. This is the width measurement
line shown in Figure 5-32. Next, estimate and mark
the length and height relative to the measurement
line (see Figure 5-33). Sketch the three-dimensional
box by using lines parallel to the original axis lines
(see Figure 5-33). The box must be sketched correctly; otherwise the rest of your sketch will be out
of proportion. All lines drawn in the same direction
must be parallel.
ne
s li
ct
pth
r
asu
Me
e
ed
of
je
ob
hi
gt
n
alo
4th
E
LIN
30° APPROXIMATELY
1st LINE — GROUND LINE
FIGURE 530 Isometric axes.
FIGURE 531 Given structure.
Architectural Drafting and Design
Ab
ou
t1
1/4
as
lon
ga
sw
idt
h
About 1 1/2 as long as width
74
h
dt
Wi
FIGURE 532 Step 4: Lay out length, width, and height.
FIGURE 534 Step 5: Sketch the features of the structure.
NONISOMETRIC LINES
FIGURE 533 Step 4: Sketch the three-dimensional box.
ISOMETRIC LINES
STEP 5 Lightly sketch the features that define the details
of the object. When you estimate distances on the
rectangular box, you will find that the features of the
object are easier to sketch in correct proportion than
they would be if you tried to draw them without the
box (see Figure 5-34).
STEP 6 Darken all the outlines to finish the sketch, as
shown in Figure 5-35.
Sketching Nonisometric Lines
Isometric lines are lines on or parallel to one of the three
original isometric axes. All other lines are nonisometric
lines. Isometric lines can be measured in true length.
Nonisometric lines appear either longer or shorter than
their actual length (see Figure 5-35).
You can measure and draw nonisometric lines by
connecting their endpoints. Find the endpoints of the
nonisometric lines by measuring along isometric lines.
FIGURE 535 Step 6: Darken the structure.
To locate where nonisometric lines should be placed,
you have to relate to an isometric line.
Sketching Isometric Circles and Arcs
Circles and arcs appear as ellipses in isometric views.
To sketch isometric circles and arcs correctly, you need
to know the relationship between circles and the faces,
or planes, of an isometric cube. Depending on which
isometric plane the circle appears, isometric circles look
like one of the ellipses shown in Figure 5-36. The angle
at which the isometric circle slants is determined by the
surface on which the circle is to be sketched.
Using the Four-Center Method to Sketch
Isometric Circles
The four-center method of sketching an isometric circle
is fairly easy, but care must be taken to form the ellipse
Chapter 5: Sketching Applications
75
1
2
22
LEFT PLANE
HORIZONTAL PLANE
RIGHT PLANE
1
1
FIGURE 536 Isometric circles.
arcs properly so the ellipse does not look distorted. Use
the following steps to sketch isometric circles using the
four-center method:
STEP 1 Sketch an isometric cube or box similar to
Figure 5-37.
STEP 2 On each surface of the box sketch line segments
connecting the 120° corners to the centers of the
opposite sides as shown in Figure 5-38.
STEP 3 With points 1 and 2 as the centers, sketch
arcs beginning and ending at the centers of the
opposite sides on each isometric surface (see
Figure 5-39).
STEP 4 On each isometric surface, with points 3 and
4 as the centers, complete the isometric circles by
sketching arcs that meet the arcs sketched in Step 3
(see Figure 5-40).
Sketching Isometric Arcs
Sketching isometric arcs is similar to sketching isometric circles. First, block out the overall shape of the
object. Next, establish the centers of the arcs. Finally,
sketch the arc shapes. Remember that isometric arcs,
just like isometric circles, must lie in the proper plane
and have the correct shape.
120°
CORNER
6 PLACES
2
1
FIGURE 539 Step 3: Sketch arcs from points 1 and 2.
HORIZONTAL
(TOP) PLANE
3
3
LEFT
PLANE
3
4
4
RIGHT
PLANE
FIGURE 540 Step 4: Sketch arcs from points 3 and 4.
ORTHOGRAPHIC PROJECTION
Orthographic projection is any projection of features
of an object onto an imaginary plane called a plane of
projection. The projection of the features of the object
is made by lines of sight that are perpendicular to the
plane of projection. When a surface of the object is
parallel to the plane of projection, the surface appears
in its true size and shape on that plane. In Figure 5-41,
the plane of projection is parallel to the surface of the
object. The line of sight from the object is perpendicular
to the plane of projection. Notice also that the object
appears three-dimensional, which means the object has
width, depth, and height. The view on the plane of projection is two-dimensional, which means the view has
only width and height. In situations where the plane of
projection is not parallel to the surface of the object, the
resulting orthographic view is foreshortened, or shorter
than the true length, as shown in Figure 5-42.
3
MULTIVIEW PROJECTION
FIGURE 537 Step 1: Isometric
cube.
FIGURE 538 Step 2: Fourcenter construction of an
isometric ellipse.
As a review, multiview projection establishes two or
more views of an object as projected on two or more
planes by using orthographic projection techniques.
76
Architectural Drafting and Design
OBJECT
5
2
PLANE OF PROJECTION
3
2
1
6
1
1
5
3
4
4
2
2
3
6
1
5
LINES OF SIGHT
PROJECTORS
PERPENDICULAR
TO PLANE OF
PROJECTION
1
3
LINES OF SIGHT
PROJECTORS
PERPENDICULAR
TO PLANE OF
PROJECTION
4
5
4
PLANE OF PROJECTION
ORTHOGRAPHIC VIEW
ORTHOGRAPHIC VIEW
FORESHORTENED
ORTHOGRAPHIC VIEW
OF SURFACE 1, 2, 3, 4
2
TRUE SHAPE OF THE
ORTHOGRAPHIC VIEW
1
PLANE OF PROJECTION
3
1
5
2
6
4
3
5
4
TRUE SHAPE ORTHOGRAPHIC
VIEW OF SURFACE 2, 3, 5, 6
PLANE OF PROJECTION
FIGURE 542 Projection of a foreshortened orthographic surface.
FIGURE 541 Orthographic projection to form orthographic view.
The result of multiview projection is a multiview drawing. Multiview drawings represent the shape of an
object using two or more views. The six possible views
include: the front, top, right side, left side, bottom,
and rear. All six views are seldom used. Consideration
should be given to the choice and number of views so,
when possible, the surfaces of the object are shown in
their true size and shape. If you can hold an object in
your hands, you can visualize the views by turning the
object until you are looking directly at a side. Continue
turning the object, stopping to look at each view as your
line of sight becomes perpendicular to the object surface. Figure 5-43 is a graphic representation of a person
holding and rotating an object in this manner. As the
object is rotated to each position, the person stops to
look directly at the object surface. What the person sees
at each of these positions is related to the specific multiview seen in proper positions within a set of multiviews
in Figure 5-43. Some people can visualize multiviews
better than others. If you have difficulty visualizing
views, pick up any object and try to sketch what you see
as you rotate the object looking at each side. Holding
an object and rotating to see the sides works well if you
can pick up and hold the object. To see the views of
your home, for example, go outside and stand so you
can see the front of the house with your line of sight as
perpendicular as possible to the front. This is the front
view. You can do the same thing by walking around
your home and stopping to look at each side in the same
manner. Take a sketch pad and sketch what you see at
each location, just like you do when holding an object.
Elevations as Multiviews
It is often easier to visualize a three-dimensional drawing
of a structure than it is to visualize a two-dimensional
drawing of the same structure. In architectural drafting, however, it is common to prepare construction
drawings showing two-dimensional exterior views of a
structure that provide representations of exterior materials or interior views of features such as kitchen and
bath cabinets. These drawings are called elevations. The
method used to draw elevations is multiview projection.
Chapter 5: Sketching Applications
77
TOP VIEW
REAR VIEW
LEFT-SIDE VIEW
FRONT VIEW
RIGHT-SIDE VIEW
BOTTOM VIEW
FIGURE 543 A graphic representation of a person holding and rotating an object. As the
object is rotated to each position, the person stops to look directly at the object surface. What
the person sees at each of these positions is related to the specific multiview seen in proper
positions shown.
A more detailed discussion of elevation drawing is
found in Chapter 24 and Chapter 25. Figure 5-44
shows an object represented by a three-dimensional
drawing, called a pictorial drawing, and three twodimensional views. This is the same object that the
TOP OR
PLAN VIEW
TOP (PLAN VIEW)
FRONT
SIDE
FRONT VIEW
SIDE VIEW
FIGURE 544 Comparison of a pictorial and a multiview
presentation.
person is holding in Figure 5-43. Look at the object
represented in Figure 5-43 and compare it to the pictorial and multiview drawing shown in Figure 5-44.
Using the Glass Box Viewing Method
If you place the object in Figure 5-44 in a glass box
so the sides of the glass box are parallel to the major
surfaces of the object, you can project the surfaces of
the object onto the sides of the glass box and create
the multiviews shown in Figure 5-45. Imagine the
sides of the glass box are the planes of projection
previously described. Look at Figure 5-45 again to
see if you can visualize this idea. If you look at all
sides of the glass box, you see the six views: front,
top, right side, left side, bottom, and rear. Now,
unfold the glass box as if the corners were hinged
about the front view as demonstrated in Figure 5-46.
These hinge lines are commonly called fold lines.
78
Architectural Drafting and Design
TOP
TOP
REAR
LEFT
RIGHT
FRONT
BOTTOM
FIGURE 547 Glass box unfolded.
FRONT
SIDE
FIGURE 545 Glass box.
Completely unfold the glass box onto a flat surface, and you have the six views of an object represented in a multiview. Figure 5-47 shows the glass
box unfolded. Notice also that the views are labeled:
TOP
front, top, right, left, bottom, and rear. Views are
always found in this arrangement when using multiview projection. Now, analyze Figure 5-48 in detail
so you see the features that are common among the
views. Knowing how to identify the features of an
object that are common among views can aid you
later in the visualization of elevations.
Notice again how the views are aligned in
Figure 5-48. The top view is directly above and the
bottom view is directly below the front view. The left
side is directly to the left and the right side is directly
to the right of the front view. This alignment allows
the drafter to project features from one view to the
next to help establish each view.
Now, look closely at the relationship of the front,
top, and right-side views. A similar relationship
exists using the left-side view. Figure 5-49 shows
a 45° projection line established by projecting the
fold or reference line (hinge) between the front and
side view up, and the fold line between the front
and top view over. All of the features established
on the top view can be projected to the 45° line
and then down onto the side view. This is possible
because the depth dimension is the same in both
the top and the side views. The reverse is also true.
WIDTH
FRONT
TOP
SIDE
HEIGHT
REAR
LEFT
FRONT
RIGHT
DEPTH
BOTTOM
FIGURE 546 Unfolding the glass box at hinge lines, also
called fold lines.
FIGURE 548 View alignment.
Chapter 5: Sketching Applications
79
FOLD LINE
45°
Y
X
FOLD LINE
FOLD LINE
FOLD LINE
X
Y
FIGURE 549 Establishing a 45° projection line.
FIGURE 551 Using dividers to transfer view projections.
Features from the side view can be projected to the
45° line and then over to the top view.
The transfer of features in Figure 5-49 using the
45° line can also be accomplished by using a compass
with one leg at the intersection of the horizontal and
vertical fold lines. The compass establishes the relationship between the top and side views, as shown in
Figure 5-50.
Another method for transferring the size of features from one view to the next is the use of dividers to transfer distances from the fold line at the top
view to the fold line at the side view. The relationship
between the fold lines and the two views is shown in
Figure 5-51.
The front view is usually most important because it
is the one from which the other views are established.
There is always one common dimension between adjacent views. For example, the width is common between
the front and top views and the height is common
between the front and side views. This knowledge
allows you to relate information from one view to
another. Take one more look at the relationship of the
six views, as shown in Figure 5-52.
RADIUS
FOLD LINE
TOP
REAR
LEFT
FRONT
RIGHT
BOTTOM
FIGURE 552 Multiview orientation.
Proper View Selection
There are six primary views that you can use to describe
a structure completely. In architectural drafting, the
front, left-side, right-side, and rear views are used as
elevations to describe the exterior appearance of a
structure completely. Elevation drawings are discussed
in more detail in Chapter 24 and Chapter 25. The top
view is called the roof plan view. This view shows the
roof of the structure and provides construction information and dimensions. Roof plans are discussed in detail
in Chapter 22 and Chapter 23. The bottom view is not
used in architectural drafting.
PROJECTION OF FEATURES
FROM AN INCLINED PLANE
FOLD LINE
FIGURE 550 Projection with a compass.
When you use multiview projection, features of
objects that are parallel to projection planes appear
true size and shape, but features that are not parallel
to projection planes are foreshortened, and are not in
true size and shape.
80
Architectural Drafting and Design
ROUND WINDOW
LINE OF INTERSECTION
ROUND WINDOW
FORESHORTENED
SKYLIGHT
TRUE WIDTH
ROOF
PROJECTION LINES
FIGURE 553 Rectangular features on an inclined plane.
FIGURE 554 Round window is a circle when the line of sight
is perpendicular.
FORESHORTENED DIAMETER
MINOR DIAMETER
Rectangular Features on an Inclined
Plane
When a rectangular feature such as a skylight projects out of a sloped roof, the intersection of the
skylight with the roof appears as a line when the
roof also appears as a line. This intersection can
then be projected onto adjacent views, as shown in
Figure 5-53.
SKYLIGHT DIAMETER
MAJOR DIAMETER
TOP
(ROOF PLAN)
Circles on an Inclined Plane
When the line of sight in a view is perpendicular
to a circle, such as a round window, the window
appears round, as shown in Figure 5-54. When a
circle is projected onto an inclined surface, such as
a round skylight projected onto a sloped roof, the
view of the inclined circle is elliptical, as shown in
Figure 5-55.
FORESHORTENED
DIAMETER
MINOR DIAMETER
SKYLIGHT DIAMETER
MAJOR DIAMETER
ROUND
SKYLIGHT
FRONT
SIDE
FIGURE 555 Circle projected onto an inclined surface appears
as an ellipse.
CADD APPLICATIONS
Using CADD for Conceptual Design and Presentation Sketches
Google SketchUp is a CADD program that can be used
to create, share, and present three-dimensional models
with an easy-to-use interface. Interface, also called user
interface, is the term describing the tools and techniques
used to provide and receive information to and from a
computer application. Google SketchUp is often used in
the conceptual design phase of a project and to create
presentation drawings that look hand-sketched, as
shown in Figure 5-56.
Tools such as Line, Arc, Rectangle, and Circle are
used to sketch two-dimensional (2D) closed boundaries,
known as faces. Then, tools such as the Push/Pull,
Follow-Me, and Move are used to “pull” faces and edges
into three-dimensional (3D) objects (see Figure 5-57).
CADD graphic and image files can be imported into
Google SketchUp, and then traced over with sketch
tools to create quick 3D models for design studies (see
Figure 5-58).
Chapter 5: Sketching Applications
CADD APPLICATIONS
FIGURE 556 Google SketchUp can be used in the conceptual design phase to sketch new ideas and designs.
Courtesy Ron Palma, 3D-DZYN.
FIGURE 557 In Google SketchUp, use sketch lines to create faces, then push/pull the faces into 3D geometry.
Courtesy Ron Palma, 3D-DZYN.
81
82
Architectural Drafting and Design
CADD APPLICATIONS
FIGURE 558 Google SketchUp lines are traced over an
imported image to create a 3D model. Courtesy Ron Palma, 3D-DZYN.
“hand-sketched” styles, and shadows to create
presentation drawings as shown in Figure 5-59.
Custom appearances can be used to create a sampling
of different presentation styles.
When Google SketchUp is combined with Google
Earth, a location from Google Earth can be found and
imported into Google SketchUp. A new design idea
is sketched relative to the Google Earth location. The
Google SketchUp file is then imported back into Google
Earth to create a 3D presentation file of the design within
Google Earth as shown in Figure 5-60.
Google SketchUp is available for download from the
Google Web site and comes in two formats. Google
SketchUp is a free download and allows you to create 3D
models very quickly. Google SketchUp Pro is a premium
version and includes all of the tools from the free
version plus advanced settings for commercial use and
interaction with other CADD programs. ■
In addition to sketching and modeling tools,
Google SketchUp can be used to add finish materials,
FIGURE 559a Apply different materials and sketch styles to 3D model geometry to create unique presentation drawings.
Courtesy Ron Palma, 3D-DZYN.
Chapter 5: Sketching Applications
CADD APPLICATIONS
FIGURE 559 b Continued
FIGURE 560 Use Google Earth to import a site into Google SketchUp, design the 3D model, then send the model back to Google
SketchUp for design review. Courtesy Ron Palma, 3D-DZYN.
83
84
Architectural Drafting and Design
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to help
you find information related to sketching applications.
Address
www.sketchup.google.com
www.drawsketch.about.com
Company, Product,
or Service
Google Sketch Up
Sketching lessons and
tutorials
Sketching Applications Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
Question 5–13 When is a surface foreshortened in an
orthographic view?
1. Letter your name, Chapter 5 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer.
You do not need to write the question. Answers can be
prepared on a word processor if approved by your course
guidelines.
Question 5–15 Give at least two reasons why the multiviews of an object are aligned in a specific format.
Question 5–1 Define sketching.
Question 5–2 How are sketches useful in CADD?
Question 5–3 Describe the proper sketching tools.
Question 5–4 Should paper for sketching be taped to
the drafting board or table? Why or why not?
Question 5–5 What kind of problem can occur if a long,
straight line is drawn without moving the hand?
Question 5–6 What type of paper should be used for
sketching?
Question 5–7 Briefly describe a method that can be used
to sketch irregular shapes.
Question 5–14 How many principal multiviews of an
object are possible?
Question 5–16 In architectural drafting, what are the
exterior front, right-side, left-side, and rear views
also called?
Question 5–17 If a round window appears as a line in
the front view and the line of sight is perpendicular
to the window in the side view, what shape is the
window in the side view?
Question 5–18 If a round skylight is positioned on a
5/12 roof slope and appears as a line in the front view,
what shape is the skylight in the side view?
Question 5–19 Briefly describe the trammel method for
sketching a circle.
Question 5–20 Why must the paper be free to rotate
when you are using the hand-compass method for
sketching a circle?
Question 5–8 Define isometric sketch.
Question 5–21 What is the distance from the center of a
circle to the circumference called?
Question 5–9 What is the difference between an
isometric line and a nonisometric line?
Question 5–22 Name the distance that goes all the way
across a circle and passes through the center.
Question 5–10 What do proportions have to do with
sketching techniques?
Question 5–11 Define orthographic projection.
Question 5–23 Describe an easy way to sketch a 15"
circle on paper and a 6'–6" circle at a construction
site.
Question 5–12 What is the relationship between the
orthographic plane of projection and the projection
lines from the object or structure?
Question 5–24 In a short but complete paragraph,
discuss the importance and use of measurement lines
and proportions in sketching objects.
Chapter 5: Sketching Applications
Question 5–25 Briefly describe how the block technique
works for making sketches of objects.
85
elements large enough to fill most of an 8 1/2 × 11"
sheet of paper.
Question 5–26 Name two basic applications for
multiviews in architectural drafting.
Question 5–27 In multiview projection, what is the top
view commonly called?
PATIO
Question 5–28 Name the four views that are commonly
used as elevations to describe the exterior appearance
of a structure.
Question 5–29 Why should a soft lead and
slightly rounded pencil point be used when
sketching?
SWIMMING
POOL
Question 5–30 Briefly describe how you would use
your pencil to establish measurements if you were
sketching a house across the street.
PROBLEMS
DIRECTIONS: On 8 1/2" × 11" bond paper or newsprint, use
proper sketching materials and techniques to solve the following sketching problems. Use very lightly sketched construction
lines for all layout work. Darken the lines of the object, but do
not erase the layout lines.
Additional problems are available on the Student CD.
Problem 5–1 Sketch the front view of your home or
any local single-family residence using the block
technique. Use the measurement-line method to
approximate proper proportions.
SPA
Problem 5–8 Given the top and side views shown in the
sketch for this problem, redraw these views and draw
the missing front view, filling most of an 8 1/2 × 11"
sheet of paper.
Problem 5–2 Use the box method to sketch a circle
with a diameter of approximately 4". Sketch the
same circle using the trammel and hand-compass
methods.
Problem 5–3 Find an object with an irregular shape,
such as a French (irregular) curve, and sketch
a two-dimensional view using the grid method.
Sketch the object to correct proportions without
measuring.
Problem 5–4 Use the same structure you used for
Problem 5–1, or a different structure, to prepare an
isometric sketch.
Problem 5–5 Use the same structure you used for
Problem 5–1 to sketch a front view and right-side view.
Problem 5–6 Use a scale of 1/4" = 1'–0" to draw a 38°
acute angle with one side horizontal and both sides
8'–6" long.
Problem 5–7 Given the sketch for this problem of
a swimming pool, spa, and patio, resketch these
START VIEW HERE
86
Architectural Drafting and Design
Problem 5–9 Given the pictorial sketch for this
problem, draw the front, top, and right-side views,
filling most of an 8 1/2 × 11" sheet of paper.
FRO
NT
Problem 5–10 Given the three views of the house shown
in the sketches for this problem, sketch an isometric
view, filling most of an 8 1/2 × 11" sheet of paper.
CHAPTER 6
Architectural Lines
and Lettering
I
N
T
R
O
D
U
C
T
I
O
N
Drafting is a universal graphic language that uses lines, symbols, dimensions, and notes to describe a structure to be built.
Lines and lettering on a drawing must be of a quality that reproduces clearly. Properly drawn lines are dark, crisp, sharp, and of
a uniform thickness. There should be no variation in darkness,
only a variation in thickness, known as line contrast. Certain
lines are drawn thick to stand out clearly from other information on the drawing. Other lines are drawn thin. Thin lines are
not necessarily less important than thick lines, but they can be
subordinate for identification purposes. Recommended line
thicknesses are much more defined in mechanical drafting for
manufacturing than in architectural drafting. Architectural drafting line standards have traditionally been more flexible, and the
creativity of the individual drafter or company can influence line
and lettering applications. This is not to say that drafters can
do anything that they desire when preparing an architectural
drawing. This chapter presents some general guidelines, styles,
and techniques that are recommended for architectural drafting.
Practices using CADD are covered in Chapter 7 and applied to
specific content in later chapters.
TYPES OF LINES
Lines are the primary method of displaying images
on architectural drawings. The lines must accurately
and clearly represent the drawing content. There are
a variety of line types found on drawings. Each type
of line conveys a meaning in the way it is represented
and its placement on the drawing. There are basically
two widths of lines commonly found on architectural
drawings, thick and thin. The purpose of different line
widths is to make certain that lines stand out more than
others. Thicker lines are meant to be more dominant
than other lines. They may not be any more important,
but they are the first lines that are intended to be seen
by the viewer. For example, when you look at a floor
plan, the wall lines and related features should be the
main focus at first glance. Other lines, such as dimension lines, are equally important, but their appearance
is subordinate to the lines used to create the plan. Even
though national standards recommend two different
line thicknesses for use on drawings, some companies
use three line thicknesses to represent different lines
on a drawing. Confirm the actual practice used by your
school or company. This discussion introduces you to
each of the lines commonly used in architectural drafting. Figure 6-1 shows each type of architectural line
and its desired width.
Construction Lines and Guidelines
Construction lines are used for laying out a drawing.
They are drawn very lightly so they do not reproduce
and so they are not mistaken for any other lines on
the drawing. Manually drawn construction lines are
drawn with very little pressure using a pencil with 4H
to 6H lead, and if drawn properly do not need to be
erased. Use construction lines for all preliminary work.
Construction lines are drawn on a separate layer when
CADD is used. This layer can be turned on or off as
needed. CADD layers are discussed in Chapter 7.
Guidelines are similar to construction lines in that
they should be drawn lightly enough so they do not
reproduce. Guidelines are drawn to guide your manual
lettering. For example, if lettering on a drawing is 1/8"
(3 mm) high, then the lightly drawn guidelines are
placed 1/8" (3 mm) apart. Guidelines are not used
with CADD.
Some manual drafters prefer to use a light-blue lead
rather than a graphite lead for all construction lines
and guidelines. Light-blue lead does not reproduce in a
diazo printer and is usually cleaner than graphite. Blueline can reproduce in a photocopy machine unless it is
drawn very lightly.
Object Lines
In architectural drafting the outline lines—or object
lines, as they are commonly called—are a specific thickness so they stand out from other lines, as they form
the outline of views. Object lines are used to define the
outline and characteristic features of architectural plan
components, but the method of presentation can differ
87
88
Architectural Drafting and Design
THICK
VISIBLE OBJECT LINES
THICK LINE APPROXIMATE WIDTH: 0.025" (0.6 mm)
FLOOR PLAN WALL OUTLINES, ELEVATION OUTLINE/ACCENT,
SECTION ACCENT, FOUNDATION OUTLINES AND BEAMS
THIN
THIN LINE
THIN LINE APPROXIMATE WIDTH: 0.012" (0.3 mm)
FLOOR PLAN SYMBOLS, ELEVATION FEATURES,
SECTION FEATURES
THIN
HIDDEN LINE
THIN LINE APPROXIMATE WIDTH: 0.012" (0.3 mm)
THIN
CENTER LINE
EXTENSION LINE
LEADER
DOT
DIMENSION LINE
DIMENSION LINE,
EXTENSION LINE,
AND LEADER LINE
THIN
20'0"
SLASH
ARROWHEAD
THICK
CUTTING-PLANE LINE
OR
VIEWING-PLANE LINE
THICK
THICK
THICK
SHORT BREAKS
BREAK LINE
THIN
LONG BREAKS
THICK
CHAIN LINE
THICK LINE APPROXIMATE WIDTH: 0.025" (0.6 mm)
PROPERTY LINES
DIMENSION LINE
VISIBLE OBJECT LINE
GARB. DISP.
GFI
GFI
DW
HIDDEN LINE
HOOD W/ LIGHT
& FAN. VENT TO
OUTSIDE AIR
12'-0"
LEADER
LINE
REFR
48"X72" LIGHT SOFFIT W/
5-48" PERIOD FIXTURES
S3
DBL
OVEN
HIDDEN LINE
BREAK
LINE
BRM
S S
3
EXTENSION LINE
CUTTING-PLANE LINE
THIN LINE
FIGURE 61 Recommended architectural line styles and weights, with an example as used in a partial floor plan.
Chapter 6: Architectural Lines and Lettering
89
slightly from one office to another. The following techniques are alternatives for object line presentation:
● A popular technique is to enhance certain drawing features so they stand out clearly from outer
items on the drawing. For example, the outline of
floor plan walls and partitions, or beams in a cross
section, can be drawn thicker than other lines so
that they are more apparent than the other lines on
the drawing. When drawn manually, these thicker
lines can be drawn with a mechanical pencil or
0.7-mm or 0.9-mm automatic pencil using a 2H,
H, or F lead (see Figure 6-2A). This technique can
also use light shading to highlight the walls of a
floor plan. Dark shading can be used, but it hides
the thicker outline lines.
● Another technique is for all lines of the drawing to
be the same thickness. This method does not differentiate one type of line from another, except that
construction lines are always very lightly drawn.
The idea of this technique is to make all lines
medium-thick to save drafting time. The drafter
uses a lead that works best, although a mechanical
pencil or 0.5-mm automatic pencil with 2H or H
lead is popular (see Figure 6-2B). This technique
can use dark shading to highlight features such as
walls in floor plans, as shown in Figure 6-2C. The
objective with any manual drafting line work is to
get all lines dark and crisp. If the lines are fuzzy,
they do not reproduce well.
●
Some object lines may not be drawn as thick as
others. This idea can be confusing at first. When
you are creating an architectural drawing, you need
to think about what features you want to be most
visual. On a floor plan, for example, the outlines of
the walls might be drawn thick to stand out clearly
from other features. However, the outlines of cabinets, doors, and other objects might be drawn thin
even though they are objects and their outlines might
be considered object lines. The partial floor plan in
Figure 6-1 shows this variation between object lines.
Although this practice is common, the confusion
can be compounded for the beginner because some
variations can exist between offices. The best thing
for you to do is spend as much time as you can looking at sets of architectural drawings with the goal
of observing how lines are displayed. Also, quickly
become familiar with the methods preferred by your
instructor and the company where you work.
10'–0"
10'–0"
5'–0"
5'–0"
5'–0"
5'–0"
ALL LINES SAME
THICKNESS
THICK WALL OUTLINES
B
10'–0"
5'–0"
5'–0"
THICK LINES
FOR BEAMS
AND FOOTINGS
DARK SHADING
A
THICK LINES FOR
FOUNDATION WALL
C
FIGURE 62 (A) Thick outlines. (B) All lines the same thickness. (C) Accent with shading.
90
Architectural Drafting and Design
Dashed Lines
In mechanical drafting dashed lines are called hidden
lines; the terms are interchangeable in architectural
drafting. Dashed lines are used to show drawing features that are not visible in the view or plan. In architectural drafting, dashed lines can also be considered
hidden lines because they are used to show drawing
features that are not visible in the view or plan. These
dashed features are important but subordinate to the
main emphasis of the drawing.
Dashed lines vary slightly from one office to the next.
These lines are thin and generally drawn about 1/8" to
3/8" (3 to 10 mm) in length with a space of 1/16" to
1/8" (1.5 to 3 mm) between dashes. The dashes should
be kept uniform in length on the drawing, for example,
all 1/4" (6 mm) should have equal spaces. Dashed lines
are thin, and the spacing between dashes should not be
measured, but should be approximately the same. Draw
dashed lines manually by estimating the dash length
and spacing. It takes practice to manually draw dashed
lines. Recommended leads for manual drafting are a
0.5-mm automatic pencil with 2H or H lead, or a sharp
mechanical pencil with 4H, 2H, or H lead. Examples
of dashed-line representations include beams shown
in Figure 6-3, headers shown in Figure 6-4, and upper
kitchen cabinets, dishwasher, and electrical circuit runs
as shown in Figure 6-5. These concepts are discussed
again throughout this textbook as used with specific
applications.
Extension and Dimension Lines
Extension lines show the extent of a dimension.
Dimension lines show the length of the dimension and
terminate at the related extension lines with slashes,
4 X 12
BEAM
DASHED LINE BEAM
FIGURE 63 Dashed line beam representation.
4 X 14
HDR.
DASHED LINE HEADER
FIGURE 64 Dashed line header representation.
DASHED LINE
DISHWASHER
DASHED LINE
UPPER CABINETS
DASHED LINE ELECTRICAL
CIRCUIT RUN
FIGURE 65 Dashed lines for upper kitchen cabinets, dishwasher, and electrical circuit runs.
arrowheads, or dots. The dimension numeral in feet
and inches, or millimeters, is generally placed above and
near the center of the dimension line. Extension lines
generally start a short distance, such as 1/16" (1.5 mm)
away from the feature being dimensioned and typically
run 1/8" (3 mm) beyond the last dimension line. When
you are dimensioning to a feature such as the center of
a window, the center line becomes an extension line.
Figure 6-6 shows several extension and dimension
lines. Further discussion and examples are provided
in later chapters. Extension and dimension lines are
generally thin, dark, crisp lines that can be drawn with
a sharp mechanical pencil or 0.5-mm automatic pencil
using 4H, 2H, or H lead, depending on the amount of
pressure you use.
Leader Lines
Leader lines are also thin, dark, crisp lines. These
lines are used to connect notes to related features
Chapter 6: Architectural Lines and Lettering
91
DIMENSION LINE
10'-0"
EXTENSION
LINE
5'-0"
5'-0"
1/8
45°
CENTER-LINE
EXTENSION
LINE
FREEHAND SLASH
ALL IN THE SAME
DIRECTION
10'-0"
5'-0"
1/8"
A THICK SLASH
IS COMMON ON
MANY MANUAL
AND CADD
DRAWINGS
SOME COMPANIES
USE A DOT TO
END DIMENSION
LINES
TO 3/16"
5'-0"
1/16
FREEHAND
ARROWHEAD
CADD ARROWHEADS MAY BE FILLED
OR UNFILLED
FIGURE 66 Extension and dimension lines.
on a drawing. Leader lines can be drawn freehand or
with an irregular curve. Do them freehand if you can
do a good job, but use an irregular curve if they are
not smooth. Confirm the preferred practice with your
school or company standards. The leader should start
from the vertical center at the beginning or end of a
note and be terminated with an arrowhead at the feature. Some companies prefer that leaders be straight
lines beginning with a short shoulder and angling to
the feature. Figure 6-7 shows several examples.
2 X 6 PT
SILL
1/2"o X 10" A.B.
@ 6'–0" O.C.
8" X 16"
CONC. FTG.
8" THICK
FND. WALL
ALL
FIGURE 67 Sample leader lines. The style for leaders should
be the same throughout the drawing.
Break Lines
Break lines are used, for example, to remove a portion of an object, to show a partial view, or to shorten
a long object. Break lines are also used to terminate
features on a drawing when the extent of the feature has been clearly defined. Two types of break
lines can be used in architectural drafting: the long
break line and the short break line. The long break
line is normally associated with architectural drafting, and uses a break symbol that is generally drawn
freehand. Figure 6-8A shows several examples. The
short break line can be found on some architectural
drawings. This line, as shown in Figure 6-8A, is an
irregular line drawn freehand and is used for a short
area. The short break line is less commonly used in
architectural drafting than the long break line. Breaks
in cylindrical objects such as steel bars and pipes are
shown in Figure 6-8B.
LINE TECHNIQUES
For more information and instructions covering manual drafting techniques for drawing
lines with pencil on vellum, polyester lead on polyester
film, and inking on vellum and polyester film, refer to
the Student CD: LINE TECHNIQUES.
92
Architectural Drafting and Design
LONG BREAK LINE
1/3 R
R
LONG BREAK LINE
ALTERNATE SYMMETRICAL
ABOUT CENTER
1/2 R
SHORT BREAK LINE
NOT AS COMMON
A
R
B
FIGURE 68 (A) Solid break lines. (B) Cylindrical break lines.
CADD APPLICATIONS
Drawing Lines
INTRODUCTION
POINT ENTRY METHODS
The process of specifying points to create and edit
objects, such as locating line endpoints, is known as
SINK
2'–0"
W
WASHER
DRYER
R
8'–0"
6"
BACKK
SPLASH
ADJ. SHELVES
L
3'–0"
Drawing line segments is one of the simplest forms of
CADD. To draw a line, first access the proper line tool or
command. Typically, a line is drawn by specifying a start
point and an endpoint. Both points are often known as
endpoints. The line appears between the selected points.
Usually the LINE command remains active, allowing you
to create multiple connected single line segments. When
finished, exit the LINE command or restart the command
to draw other disconnected lines.
Drawing lines using a LINE command represents
the fundamental approach to creating computer-aided
drawings, because a drawing is a grouping of lines
and shapes. Figure 6-9, for example, shows an interior
elevation drawing. If you look closely, you can see how
the drawing consists of lines and different line types. As
you learn more about CADD and specific CADD systems,
you will become more familiar with the commands and
options that allow you to create and modify complex
objects without using individual line segments.
5'–3"
4
1'–10"
UTILITY ELEVATION
A
FIGURE 69 An example of a utility room interior elevation.
The drawing consists of lines assigned specific line types,
created using LINE and OBJECT commands.
point entry. A common traditional method of point entry
relies on the Cartesian coordinate system, also referred
to as rectangular coordinates. This system is based on
Chapter 6: Architectural Lines and Lettering
93
CADD APPLICATIONS
establishing points at a given distance from the x, y, and z
axes. For two-dimensional drafting applications, objects
are drawn on the x,y plane and use horizontal x and vertical
y coordinates. Three-dimensional drawings make use of
the z axis and require x, y, and z coordinate entry. The
intersection of the axes is called the origin. This is where
x = 0, y = 0, and z = 0, or the 0,0,0 coordinate is located.
Absolute coordinate entry uses the exact coordinates
from the origin to locate points. Figure 6-10 shows
the two-dimensional Cartesian coordinate system. In
this example, two lines have been drawn by entering the
absolute coordinate 2,1 followed by 2,4 and finally 4,4.
The z axis usually requires no consideration when
preparing two-dimensional drawings. The actual entry
technique varies depending on the CADD system and
work environment settings. For example, typing 2,1 or
#2,1 may be necessary to enter an absolute coordinate
two units right and one unit up from the origin.
Figure 6-10 shows how the Cartesian coordinate
system is divided into quadrants. Positive and negative
values specify coordinates from the origin in each quadrant.
Generally, the origin is in the lower left corner of the
drawing area to allow for drawing in the upper right
quadrant, using positive x,y coordinates. The drawing
area is often infinite in size, though drawing limits, or
the specified drawing area, can be set to create a virtual
drawing area according to sheet size and drawing scale.
Depending on the CADD program, many point entry
methods exist for placing objects, such as the endpoints
of lines. Absolute coordinate entry, as well as relative, and
polar coordinate entry are common. Relative coordinate
entry is used when points are located at a specified
– ,y
–x
distance on the x and y axis from the previous point.
For example, when using relative coordinate entry, and
the first point is located at 2,2 from the origin, the next
point is 2 units directly above the first point by entering
@0,2. In this example, the @ symbol indicates from the
previous point. Polar coordinate entry is used when
points are located from the previous point at a specified
distance and angle. For example, when using polar coordinate entry, and the first point is located at 2,2 from the
origin, the next point is 2 units directly above the first point
by entering @2<90. In this example, the @ symbol indicates
from the previous point and the < symbol establishes the
polar relationship. The relative and polar coordinate entry
symbols used here are for AutoCAD applications. Other
CADD systems use similar or different entry methods.
The most basic point entry technique is to pick points
using the cursor, which can appear as a crosshair, arrow,
wand, or point. Often, coordinates appear on-screen as
you move the cursor to various positions. This is known
as the coordinate display, and it constantly identifies
where the cursor is located relative to the origin or to the
previous point, as desired.
Picking a point using the screen cursor can be an
accurate method of point entry when specific tools or
options are used to aid precise point selection. AutoCAD
Snap Mode, Ortho Mode, and Polar Tracking are examples
of options that help position the cursor at designated
increments, and specified coordinates and angles. Other
AutoCAD functions, such as Object Snaps and Object
Snap Tracking, allow you to pick or reference points
on existing objects. Some tools allow you to enter the
length of the line and angle at which the line is drawn,
significantly reducing the need to consider and identify
exact coordinates. Figure 6-11 shows how a combination
of drawing aids can be used to draw a 4" long line to the
midpoint and perpendicular to an existing line.
x,y
2,4
4,4
START P
POINT AT
THE MID
DPOINT
ENTER AN ALTERNATIVE
ANGLE
2,1
ENDPOINT PERPENDICULAR
TO AND 4" FROM
THE MIDPOINT
ORIGIN 0,0
– ,–y
–x
–
x,–y
–
FIGURE 610 Using absolute coordinates and the Cartesian
coordinate system to locate line endpoints.
LENGTH AND DIRECTION
OF CURRENT LINE
ENTER THE LENGTH
OF THE LINE
FIGURE 611 An example of using drawing aids to precisely
size and locate a line.
94
Architectural Drafting and Design
CADD APPLICATIONS
ASSIGNING LINE FORMAT
In most situations, unique line formats are used when
preparing computer-aided drawings. Many systems,
such as AutoCAD layers, allow you to define the name,
color, line type, line weight (thickness), and display
characteristics for each line type and object. For
example, a line format used to draw a door on a floor
plan using visible object lines might be named Doors or
A-DOOR, use a blue color, use a solid (continuous) line
type, and have a thickness of .014" (0.35 mm). A line
format used to draw an upper cabinet on a floor plan
that uses hidden lines might be named Upper Cabinets,
A-CSWK-UPPR, or A-FLOR-CSWK-UPPR, use a red color,
use a dashed or hidden line type, and have a thickness
of .014" (0.35 mm).
Example
Figure 6-12 shows a variety of single line segments
drawn using CADD. The ability to use systems, such as
layers, is a major advantage to CADD. The line used to
represent underground natural gas lines in Figure 6-12
highlights the advantage. This complex line, complete
with text and a specific line weight, would be very time
consuming and less accurate if drawn manually.
Different line configurations can be set before or
after lines are drawn, though it is good practice to set
the line format before you begin drafting. All lines
drawn after you choose a specific format use that
format’s characteristics. You must select a different line
format each time you draw a different type of object.
Still, you can modify the properties of an existing line
using a variety of editing tools. ■
Purpose
Name
Line Type
Dimensions
A-ANNO-DIMS
Continuous 0.3 mm
Line Weight
Borders and title blocks
A-ANNO-TTBL
Continuous 0.7 mm
Doors
A-DOOR
Continuous 0.5 mm
Underground natural gas lines
A-NGAS-UNDR
GAS_LINE
0.5 mm
Property lines
A-PROP
PHANTOM
0.7 mm
Upper cabinets
A-FLOR-WDWK-DASH
DASHED
0.5 mm
FIGURE 612 Examples of common computer-aided drafting line formats.
LETTERING
Information on drawings that cannot be represented
graphically by lines can be presented by lettered
dimensions, notes, and titles. It is extremely important
that these lettered items be exact, reliable, and entirely
legible in order for the user to have confidence in them
and never have any uncertainty as to their meaning.
Poor lettering can ruin an otherwise good drawing.
The following is basic terminology commonly associated with lettering:
●
Composition refers to the spacing, layout, and
appearance of the lettering.
● Justify means to align the text. Several lines of text
that are left-justified are aligned along the left side,
for example.
● Lettering is the term used to describe the traditional
handmade letters and numbers on a drawing.
●
Text is the term for lettering that is done using
CADD. The term annotation is commonly used
in architectural CADD applications to refer to any
text, notes, dimensions, and text symbols on a
drawing.
●
A font is a complete assortment of any one size and
style of lettering or text.
●
Text style is a set of text characters, such as font,
height, width, and angle.
Lettering and text used on mechanical drafting
for manufacturing follow very strict guidelines recommended by the American Society of Mechanical
Engineers (ASME). Architectural lettering and text
requirements follow less strict principles, but have
developed as an artistic style that is commonly
used by architects, architectural designers, and
drafters.
Chapter 6: Architectural Lines and Lettering
95
A E F H I K L M
N T VW X Y Z &
BCDG J O
PQR S U
123456 78
3
1
– 3/4 –
9 0 1/2 2
4
FIGURE 613 Vertical straight element letters, curved element letters, numerals, and fractions.
Single-Stroke Lettering
The standard lettering that has been used for generations by drafters is called vertical single-stroke letters.
The term single stroke comes from the fact that each
letter is created by single straight or curved line elements that make it easy to draw and clear to read.
There are uppercase and lowercase letters, although
the industry has traditionally used uppercase lettering.
Figure 6-13 shows the recommended strokes used to
form architectural letters and numbers.
Architectural lettering styles can vary, but there
are similarities. Figure 6-14 shows typical architectural lettering. As a beginning drafter, you should
be conservative in the style you use to create architectural letters. Too much flair causes unnatural
lettering. One important point regarding lettering
technique is to make letters consistent. Do not
make a letter one way one time and another way the
next time. Also, keep letters vertical and always use
guidelines. Entry-level drafters should pay particular
attention to match the style used at the architectural firm where they are employed. A professional
FIGURE 614 Examples of architectural lettering.
96
FIGURE 615 Slanted letters (uppercase) and numerals.
drafter should be able to letter rapidly with clarity
and neatness.
Slanted Lettering
Most architectural drafting is done using vertical uppercase lettering and text, but some companies prefer
slanted lettering. These letters slant to the right with
an angle of 68° from horizontal. Structural drafting is
one field where slanted lettering is commonly found.
Uppercase slanted lettering is generally used for water
feature names in mapping, such as streams, rivers, lakes,
and oceans. Figure 6-15 shows typical slanted uppercase letters and numerals.
Lettering Height
Minimum lettering height should be 1/8" (3 mm).
Some companies use 5/32" (4 mm). All dimension
numerals, notes, and other lettered information should
be the same height except for titles, drawing numbers,
and other captions. Titles and subtitles, for example,
can be 3/16" or 1/4" (4 or 6 mm) high. The height of
numbers in fractions should be the same height as the
other lettering associated with the fraction. The fraction bar can be placed horizontally at mid height of
the whole numbers, or it can be placed diagonally. It is
common for the fraction bar to be placed horizontally
when used with dimension values and notes, but titles
often use diagonal fraction bars. The exact practice
depends on the preference of the architectural office.
Some offices allow fraction numbers to be smaller than
the other lettering, but for best readability, this is not
preferred. Verify the specific requirements with your
instructor or employer.
Lettering Legibility
Lettering should be dark, crisp, and sharp so it provides
excellent reproduction quality. The composition of letters in words and the space between words in sentences
should be such that the individual letters are uniformly
spaced, with approximately equal background areas.
Architectural Drafting and Design
To achieve uniform spacing usually requires that letters
such as I, N, or S be spaced slightly farther apart than
L, A, or W. A minimum recommended space between
letters is approximately 1/16" (1.5 mm). The space
between words in a note or title should be about the
same as the height of the letters.
Notes should be lettered horizontally on a sheet. In
some cases where space or format requires, notes can
be lettered vertically so they read from the right side of
the sheet. You should confirm if this is acceptable with
your instructor or drafting manager. When lettering
notes, sentences, or dimensions requiring more than
one line, the vertical space between the lines should be
a minimum of one-half the height of the letters. The
maximum recommended space between lines of lettering is equal to the height of the letters. Some companies
prefer to use the minimum space to conserve space,
while other companies prefer the maximum space for
added clarity. Some companies choose to exceed the
maximum space between lines by using twice the height
of letters between separate notes.
Rules for Lettering and Text Numeral
Applications
The following outlines basic rules for placing inch and
metric unit values on drawings in dimensions, notes,
and specifications:
●
Foot units are followed by the foot symbol ('), and
inch units are followed by the inch symbol (").
●
Inches and fractions are used for values less than
12 inches, as in 6". Numerals are given in feet and
inches for values equal to or over 12". A dash separates the feet and inch values, for example 8'–6".
●
Metric values in architectural drafting are generally
in millimeters; the abbreviation “mm” is not used
when all the values are in metric.
●
When metric values are used on a predominantly
foot and inch drawing, the millimeter abbreviation
symbol (mm) follows the metric value.
●
Metric unit names are lowercase, except those resulting from proper names, for example, millimeter,
meter, kilogram, Kelvin, Newton, and Pascal.
●
Use vertical text for unit abbreviations. Use lowercase text, such as mm (millimeter), m (meter), and kg
(kilogram), unless the unit name is derived from
a proper name, as in K (Kelvin), N (Newton), or
Pa (Pascal).
●
Leave a space between a numeral and an abbreviation, for example, 55 kg, 24 m, 455 Hz.
Chapter 6: Architectural Lines and Lettering
●
Do not leave a space between a unit abbreviation and
its prefix, for example, use kg, not k g.
● Do not use plural unit symbols, for example, use
5 kg, not 5 kgs.
● Use the plural of spelled-out metric measurements,
for example, 125 meters. Use either names or symbols
for units; do not mix them. Symbols are preferred on
drawings.
● Millimeters (mm) are assumed on architectural
drawings unless something else is specified.
97
HINTS FOR PROFESSIONAL
LETTERING
Refer to the Student CD: HINTS FOR
PROFESSIONAL LETTERING, for more information
on creating professional manual lettering, including
making lettering guidelines, and lettering guideline
templates. There is also a discussion covering the use
of mechanical lettering equipment, lettering machines,
and transfer lettering.
CADD APPLICATION
CADD Lettering
The term annotation is commonly used in architectural
CADD applications to refer to any text, notes, dimensions,
and text symbols on a drawing. Adding annotation to a
drawing is one of the most efficient and effective tasks
associated with CADD. CADD eliminates the usually
tedious task of freehand lettering. The process of placing
text varies depending on the CADD system, the tools and
commands used to generate the text, and the purpose
of the text. Typically, adding text involves defining
and selecting a text style, picking the text location, and
typing characters using the keyboard. Some commands
and options automatically add text to symbols and other
drawing content. For example, dimensions used to describe
the size and location of features automatically include text
of dimension values when placed. Another example is a
floor plan refrigerator symbol that when inserted, includes
the text REFR as the abbreviation for refrigerator.
TEXT STYLES
Most CADD programs contain standard, or default,
text styles. Default refers to any value maintained by
the computer for a command or function that has
variable settings. For example, the default text height
might be 1/8" (3 mm), but can be changed. Though the
default text style can be used to add text, a new
or modified style can be more appropriate.
CADD systems have multiple text options allowing
you to create text styles based on the nature of the
drawing and specified drafting standards. Font, height,
width, and slant angle are a few of the characteristics
applied to text. Figure 6-16 shows examples of CADD
text styles assigned specific fonts. Most CADD programs
include, or allow you to add, text fonts that resemble
quality freehand architectural lettering. AutoCAD, for
example, includes the CityBlueprint, CountryBlueprint,
and Stylus BT fonts. These architectural fonts allow
computer-aided drawings to have the artistic flair often
desired in architectural drafting. The examples shown
in Figure 6-16C and Figure 6-16D use an architectural
text style with fonts that closely duplicate the artistry of
freehand architectural lettering.
Many architects and architectural drafters have
adopted a less artistic style with a more computergenerated appearance. The U.S. National CAD Standard
recommends using uppercase text that is proportional
and nonstylized. The standard suggests a SanSerif or
similar font (see Figure 6-16E). A basic uniform font such
as RomanS is another alternative (see Figure 6-16F).
These fonts are very clear and easy to read, and can
eliminate misunderstanding, which occasionally results
from the use of a more architectural appearing font.
DRAWING SCALE FACTOR
Depending on the CADD program, objects should be
drawn full size, or full scale. This is a benefit to using
CADD because you can draw according to the actual
size of objects, without considering the scale factor.
However, scale factor becomes an issue when adding
text and other annotations. To help understand the
concept of drawing scale, look at the kitchen floor plan
shown in Figure 6-17. All objects, such as the walls,
cabinets, and appliances are drawn full scale. This means
that the sink, for example, is actually drawn 2' long.
However, text that is drawn at full scale, 1/8" high for
example, is extremely small compared to the other fullscale objects (see Figure 6-17A). As a result, you must
adjust the text height according to the drawing scale, as
shown in Figure 6-17B.
Some CADD programs require you to increase the
size of, or scale, text according to the drawing scale. For
example, in order for text on a final drawing, plotted at
a scale of 1/4" = 1'−0", to be 1/8" high, you must use a
text height of 6". Six inches at this scale is actually 1/8".
The scale factor establishes the relationship between
98
Architectural Drafting and Design
CADD APPLICATIONS
Arial font
A
Times font
B
CountryBlueprint
font
C
Stylus BT font
D
SanSerif font
E
RomanS font
F
FIGURE 616 (A) Arial font. (B) Times font. Architectural text styles with fonts that closely duplicate the artistry of freehand architectural lettering can be seen in (C) CountryBlueprint and (D) StylusBT. (E ) The U.S. National CAD Standard recommends using uppercase,
proportional, nonstylized text, such as the SanSerif shown here. (F ) A basic uniform font such as RomanS is another alternative.
Chapter 6: Architectural Lines and Lettering
99
CADD APPLICATIONS
9'–5"
12'–7"
REFR
A
9'–11'5"
B
FIGURE 617 An example of a kitchen floor plan drawn to scale. (A) If text is drawn full scale, the text is too small compared to
the large objects. (B) The text must be scaled in order to appear and be plotted correctly.
the drawing scale and the desired text height. An
architectural drawing to be plotted at a 1/4" = 1'−0"
scale has a scale factor of 48, calculated as follows:
1/4" = 1'−0" (1/4" = 0.25")
0.25" = 12"
12/0.25 = 48
Other CADD programs automate the process of scaling
text, and certain other objects, reducing the need for you
to calculate the scale factor. AutoCAD Annotative Object
tools, for example, allow you to select an annotation scale,
which is the same as the drawing scale. Then, when you
create text that uses an annotative text style, the text
height adjusts according to the appropriate drawing
scale text height. For example, in order for text on a final
drawing, plotted at a scale of 1/4" = 1'−0", to be 1/8" high,
you set an annotation scale of 1/4" = 1'−0". Then you draw
the text using a text height of 1/8", ignoring the drawing
scale. The 1/8" high text is scaled to 6" automatically,
because of the preset 1/4" = 1'−0" annotation scale.
Changing the annotation scale automatically updates the
height of text according to the new scale.
ADDING TEXT TO A DRAWING
In some ways, the practice of adding text to an architectural
drawing has not changed from manual drafting to CADD.
You still must decide how the text should look, and where
the text is to be located. The actual process of adding
text is, however, quite different from freehand lettering.
Depending on the CADD program, tools and commands
are available to place a basic single line of text, paragraphs
with extensive formatting, and objects that include text.
Figure 6-18 shows an example of a single word
created using a basic text command. To add this text to
a drawing, once you access the command, you typically
use point entry to specify the location for the text. Text
is justified to control where the text occurs from the
selected start point. Justified means to align the text.
Several lines of text that are left-justified are aligned
along the left side, for example.
100
Architectural Drafting and Design
CADD APPLICATIONS
TOP CENTER
MIDDLE CENTER
TOP RIGHT
TOP LEFT
MIDDLE RIGHT
MIDDLE LEFT
LEFT
RIGHT
BOTTOM LEFT
BOTTOM CENTER
CENTER
BOTTOM RIGHT
FIGURE 618 Some common justification options used to locate and position text.
be familiar. These types of commands are especially
useful in architectural drafting where an entire sheet can
consist of notes and specifications. Other commands
allow you to place text with objects such as the window
schedule, shown in Figure 6-19B, created using a table
command. Another example is the dimension shown in
Figure 6-19C, created using a dimension command. In
this example, lines, symbols, the dimension value, offsets,
and all other dimension properties are drawn using a
single dimension command. ■
5'–5"
Common justification options are shown in Figure 6-18.
Justification is critical for accurately placing text. For
example, use middle-center justification to place text in
the center of a circle. You also have the option of rotating
or further adjusting the text before it is actually created.
Figure 6-19 shows examples of other text objects
created using specific CADD commands. Some text
commands, such as the command used to create the
list of notes shown in Figure 6-19A, function much like
word processing programs with which you may already
A
B
C
FIGURE 619 (A) A list of notes created using a word processing command. (B) A window schedule created using a table command.
(C) A dimension placed using a specialized dimension command.
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to help
you find information related to drafting standards.
Address
www.aia.org
www.ansi.org
Company, Product,
or Service
American Institute of
Architects
American National
Standards Institute
Chapter 6: Architectural Lines and Lettering
101
Architectural Lines and Lettering Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
Question 6–17 What are the minimum recommended
lettering heights?
1. Letter your name, Chapter 6 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 6–19 What is the recommended space
between words in a note?
Question 6–1 Is there any recommended variation in
line darkness, or are all properly drawn lines the same
darkness?
Question 6–2 What are construction lines used for, and
how should they be drawn?
Question 6–3 Discuss line uniformity and line contrast.
Question 6–4 Define guidelines.
Question 6–5 What is the recommended thickness of
outlines?
Question 6–6 Identify two items that dashed lines
represent on a drawing.
Question 6–7 Describe a situation in which an
extension line is also the center line of a feature.
Question 6–8 Extension lines are thin lines that are
used for what purpose?
Question 6–9 Where should extension lines begin
relative to the object and end relative to the last
dimension line?
Question 6–18 How should letters within words be
spaced?
Question 6–20 What is the recommended horizontal
space between horizontal lines of lettering?
Question 6–21 When should guidelines be used for
lettering on a drawing?
Question 6–22 Why are guidelines necessary for
freehand lettering?
Question 6–23 Describe the recommended leads and
points used in mechanical and automatic pencils for
freehand lettering.
Question 6–24 Identify a method to help avoid smudging
a drawing when lettering. Refer to the Student CD:
LINE TECHNIQUES.
Question 6–25 For lettering fractions, what is the
recommended relationship of the fraction division
line to the whole numbers on the same line?
Question 6–26 List two manual methods that can be
used to make guidelines rapidly. Refer to the Student
CD: HINTS FOR PROFESSIONAL LETTERING.
Question 6–10 Describe leaders.
Question 6–27 Why should the mechanical lettering
template be placed along a straightedge when lettering?
Refer to the Student CD: HINTS FOR PROFESSIONAL
LETTERING.
Question 6–11 Describe and show an example of
three methods used to terminate dimension lines at
extension lines.
Question 6–28 Identify an advantage of using lettering
guides. Refer to the Student CD: HINTS FOR
PROFESSIONAL LETTERING.
Question 6–12 How does architectural line work differ
from mechanical drafting line work?
Question 6–29 Describe a use of lettering
machines. Refer to the Student CD: HINTS FOR
PROFESSIONAL LETTERING.
Question 6–13 What is the advantage of drawing certain
outlines thicker than other lines?
Question 6–14 If all lines on a drawing are the
same thickness, how can walls and partitions, for
example, be represented so they stand out clearly
on a floor plan?
Question 6–15 Describe the proper technique to use
for drawing lines with a technical pen. Refer to the
Student CD: LINE TECHNIQUES.
Question 6–16 Describe proper architectural lettering.
Question 6–30 List four uses of transfer materials. Refer
to the Student CD: HINTS FOR PROFESSIONAL
LETTERING.
Question 6–31 The Cartesian coordinate system is also
called what?
Question 6–32 What is the basis of the Cartesian
coordinate system?
Question 6–33 Where is the origin found in the
Cartesian coordinate system?
102
Question 6–34 How are points in the absolute
coordinate system located relative to the origin?
Question 6–35 How is an absolute coordinate
specified that is 4 units on the x axis and 3 units
on the y axis?
Question 6–36 Describe how relative coordinate points
are located.
Question 6–37 If the first point is located at 2,2, then
how do you specify the next point, using relative
coordinates, if it is to be 2 units directly above the
first point?
Question 6–38 Describe how polar coordinate points
are located.
Question 6–39 If the first point is located at 2,2, how do
you specify the next point, using polar coordinates, if
it is to be 2 units directly above the first point?
Question 6–40 Explain how a CADD system might have
commands and options that allow you to pick points
accurately with the cursor.
Question 6–41 What is the function of the coordinate
display on a CADD system?
Question 6–42 Define font.
Question 6–43 Define annotation.
Question 6–44 What does the term default mean when
applied to CADD?
Architectural Drafting and Design
second drawing, make all lines the same thickness. Each
drawing represents a line thickness technique discussed
in this chapter.
5. Use guidelines for all lettering. Using architectural lettering, letter the title FLOOR PLAN; center it below the
drawing in 1/4"-high letters. In 1/8"-high letters and
centered below the title, letter the following: SCALE:
1/4" = 1'–0". Letter your name and all other notes and
dimensions using 1/8" high architectural lettering.
6. Lightly lay out the drawing using construction lines. When
you are satisfied with the layout, darken all lines.
7. For the lettering exercise, use 1/8" guidelines with 1/8"
space between the lines.
8. Leave a 3/4" minimum margin around the lettering exercise
sheet.
9. Make a diazo print or photocopy of your original drawings or lettering exercise sheet as specified by your
instructor.
10. Submit your copies and originals for evaluation and
grading, unless otherwise specified by your instructor.
11. Problems can be completed manually or with CADD, or
both, depending on your specific course objectives and
instructions. Confirm this with your instructor.
Problem 6–1 Lines and lettering. Given the following
information, draw the garage floor plan:
1. Overall dimensions are 24'−0" × 24'−0".
Dimensions are measured to the outside of walls.
2. Make all walls 4" thick.
Question 6–45 Explain the function of a template
drawing.
3. Center a 16'−0" wide garage door in the front
Question 6–46 What is another name for a template?
4. Using dashed lines, draw a 4 × 12 header over the
Question 6–47 Discuss the purpose of drawing scale
factors related to text height.
garage door and label it 4 × 12 HEADER with a
leader from the note and pointing to the header.
Question 6–48 What drawing scale factor should
be used if you want text 1/8" (3 mm) high on a
drawing with a 1/4" = 1'−0" scale? Show your
calculations.
5. Label the garage floor 4" CONC OVER 4" GRAVEL
Question 6–49 Give at least three advantages of doing
lettering with a CADD system.
Question 6–50 Explain how it might be possible to have
CADD text that looks like high-quality architectural
freehand lettering.
PROBLEMS
DIRECTIONS:
1. Read all instructions carefully before you begin.
2. Use an 8 1/2" × 11" vellum or bond paper drawing sheet for
each drawing or lettering exercise.
3. Use the architect’s scale of 1/4" = 1'–0" for each drawing.
4. Draw the floor plan described in Problem 6–1 twice. On
the first drawing, use thick lines for the walls and thin
lines for extension, dimension, and symbol lines. On the
wall.
FILL. Use a leader.
Problem 6–2 Lettering practice. Using uppercase
architectural lettering with proper guidelines, letter
the following statement as instructed:
YOUR NAME
MOST ARCHITECTURAL DRAWINGS THAT ARE NOT MADE WITH
CADD EQUIPMENT ARE LETTERED USING VERTICAL FREEHAND
LETTERING. THE QUALITY OF THE FREEHAND LETTERING GREATLY
AFFECTS THE APPEARANCE OF THE ENTIRE DRAWING. MANY
ARCHITECTURAL DRAFTERS LETTER WITH PENCIL ON VELLUM
OR POLYESTER LEAD ON POLYESTER FILM. LETTERING IS
COMMONLY DONE WITH A SOFT, SLIGHTLY ROUNDED LEAD
IN A MECHANICAL PENCIL OR A 0.5MILLIMETER LEAD IN AN
AUTOMATIC PENCIL. LETTERS ARE MADE BETWEEN VERY LIGHTLY
DRAWN GUIDELINES. GUIDELINES ARE PARALLEL AND SPACED
AT A DISTANCE EQUAL TO THE HEIGHT OF THE LETTERS.
GUIDELINES ARE REQUIRED TO HELP KEEP ALL LETTERS THE
SAME UNIFORM HEIGHT. THE SPACE BETWEEN LINES OF
LETTERING MAY BE BETWEEN HALF TO EQUAL THE HEIGHT
OF THE LETTERS. ALWAYS USE GUIDELINES WHEN LETTERING
FREEHAND. LEARN TO RELAX SO THAT THE STROKES FOR EACH
Chapter 6: Architectural Lines and Lettering
103
Problem 6–3 Given the partial floor plan shown for this
problem, identify the line types labeled A through K.
LETTER FLOW SMOOTHLY. WHEN YOUR HAND BECOMES TIRED,
REST FOR A WHILE BEFORE BEGINNING AGAIN.
54'-0"
34'-0"
15'-6"
8'-0"
11'-9"
3'-0"
11'-0"
7'-6"
B
C
3'-9"
A
REFR
STA
ACK
PLUMBING ST
D
RANGE W/
MICRO OVER
OVER
F
E
7'-8"
R&S
4x8
I
4x8
)2
(2
8
1'-3"
X
(2) 2 X 10
R&S
4
4'-2"
3'
-8
"
R
6X8
14
UPPER FLR OVER
OVER
2'-4"
3'-4"
X
6"
J
6'-2"
10
1'-2"1'-8" 1'-10" 1'-10"
3'-6"
UP
CONC. FILLED
HARD POST
5'-4"
H
3'-8"
1'-10"
9'-6"
G
K
CHAPTER 7
Computer-Aided
Design and Drafting
in Architecture
I
N
T
R
O
D
U
C
T
I
O
N
In Chapter 3 you learned about the traditional manual drafting
workstation with conveniences such as an adjustable drafting
table and a drafting machine or parallel bar. Also available to
enhance your speed and accuracy are automatic pencils, electric erasers, and templates of all kinds. As a professional drafter,
designer, or architect, you may continue to see the traditional
equipment in some offices. However, drafting is changing.
The concepts and theories are the same, but the tools are
different. Traditional manual drafting is rapidly converting to
computer-aided design and drafting (CADD). CADD is now
available in most drafting and architectural schools and is commonly used in architectural firms. Both acronyms CADD and
CAD are commonly used to identify the use of computers in
the drafting industry. CADD, as previously mentioned, refers
to computer-aided design and drafting. CAD is the acronym
for computer-aided design, but is often used as a reference to
computer-aided drafting.
Even as the computer waits for input, architectural
designers continue to make sketches. The traditional
method of making bubble drawings to determine a preliminary room arrangement continues to be a common
practice. Designers still create sketches in an effort to
establish design ideas. The computer can help in the
design process, but individual creativity happens before
the computer is turned on.
The CADD system can perform a number of design
functions in a manner that often exceeds expectations.
Plan components, such as room arrangements, can be
stored in a design file; this allows the designer to call
on a series of these components and rearrange them
in a new design. Another aid to design is that a given
plan can be quickly reduced or enlarged in size, with all
components remaining in proportion. One particular
room can be changed while the rest of the design stays
the same. The design capability of drawing layers allows
the architect to prepare a preliminary layout on one
layer while changing and rearranging components on
another layer. Layers allow for details of a design or different drafting information to be separated. Layers are
generally of different colors and have their own names.
104
Layers can be kept together, or individual layers can be
turned on or off as needed.
Creativity is enhanced with CADD, and the repetitive aspects of design are handled more effectively. For
example, in the design of an apartment or condominium
complex, an initial unit can be designed, and then any
number of the same units can be attached to one another
as desired, very quickly. Alternative designs, such as
a reverse plan, can also be made. Some units can be
expanded or reduced in size, or alternatives for bedrooms and baths can be implemented quickly.
Architecture in education and business today uses a
vast variety of design and drafting applications from the
traditional manual drafting discussed in Chapter 3, to
the most modern form of CADD explained in the next
section. Most educational institutions and architectural
firms have evolved to CADD. CADD is here to stay and
will eventually be a part of every architectural school’s
curriculum and every office’s operational practices. The
next section gives you a look at the future of architecture.
Innovative minds are always looking for better ways to
be creative. What makes this the future is that eventually
all schools and companies will be using CADD and those
who want to use the full power and potential of CADD
will be involved in applications of this type.
ARCHITECTURAL CADD
SOFTWARE PRODUCTS
The following provides general information about a
variety of CADD software manufacturer products.
Much of the information is taken from the related Web
sites. The information provided is intended as an introduction only. For more information, refer to the list of
Web sites at the end of this chapter. This discussion is
not intended to promote or endorse any of the products
represented. Other CADD software products are available. Do an Internet search using keywords such as
computer-aided drafting, computer-aided design, computer-aided design and drafting, CADD, architectural
CADD, and CADD software to find additional products
or more information about the products listed here.
Chapter 7: Computer-Aided Design and Drafting in Architecture
Autodesk, Inc.
Autodesk’s core product is AutoCAD. AutoCAD is a
two-dimensional (2D) and three-dimensional (3D)
drafting and design software product. AutoCAD LT
software is a 2D drafting product. Autodesk products
are available for industries such as building, infrastructure, manufacturing, media and entertainment, and
wireless data. Autodesk has a variety of CADD software
programs created for specific disciplines such as architectural, civil, electrical, and mechanical. The following
provides a sample of the architectural, engineering, and
construction products: AutoCAD Civil 3D software is
used for civil engineering applications using a dynamic
engineering model. AutoCAD Architecture provides
the efficiency of real-world building objects, design,
and documentation productivity for architects and
architectural designers. AutoCAD Revit Architecture
Suite software combined with AutoCAD or AutoCAD
Architecture software gives the competitive advantage
of building information modeling (BIM). Autodesk
Revit platform for BIM is a complete architectural
design and documentation solution supporting all
phases of design and all the architectural drawings and
schedules required for a building project.
105
SolidBuilder software package was created by contractors for contractors. Features include true 3D modeling,
framing, complex roof generation, and working drawings. DetailPro makes detailing and drafting easy with
a complete library of over 200 predrawn details. Each
detail can also be customized and saved. DetailPro saves
drafting time when used with SolidBuilder. BidBuilder
estimating software is used to produce professional estimates, proposals, and bids for all types of construction
projects, with an Excel-like interface that contains the
power of a database. Digital Takeoff is on-screen takeoff
software for contractors, builders, and remodelers. A
takeoff is the quantity estimates and areas and footages
taken from a drawing.
Google
Google SketchUp is available for download from the
Google Web site and comes in two formats. Google
SketchUp is a free download and allows you to create 3D
models very quickly. Google SketchUp Pro is a premium
version and includes all of the tools from the free version
plus advanced settings for commercial use and interaction
with other CADD programs. Refer to the CADD applications feature at the end of Chapter 5 for more information.
Bentley Systems, Inc.
Graphisoft
Bentley Systems provides a wide range of software products for building areas such as plant, civil and geospatial,
architecture, engineering, construction, and operations.
MicroStation is Bentley’s key product for the design,
construction, and operation applications. MicroStation
PowerDraft is a professional CADD application used for
production 2D/3D drafting and detailing. PowerDraft
is used to create, edit, and manipulate drawings and
models, and is completely integrated with all Bentley
solutions. ProjectWise is an engineering project team
collaboration system that is used to help teams improve
quality, reduce rework, and meet project deadlines.
Generative Design and Building Performance products
are Bentley’s integrated multidisciplinary BIM software for architects, engineers, energy assessors, and
other professionals to design, analyze, construct, and
manage buildings of all types.
Graphisoft is the manufacturer of the ArchiCAD Design/
Building Series, which is a set of tools for builders and
residential designers. Graphisoft packages are based on
open standards, allowing you to create data without
recreation. A Graphisoft product called Virtual Building
manages the full information cycle of buildings from
concept through occupancy. The program contains
information about building materials and characteristics. Virtual Building is a 3D digital database that tracks
all elements that make up a building, allowing the
designer to use items such as surface area and volume,
thermal properties, room descriptions, costs, product
information, and window, door, and finish schedules.
Digital Canal Corporation
Digital Canal provides home design software, with
Building Blocks technology. This software allows you to
create house and floor plan designs, and at any point in
the process, you can take your Building Blocks design
into SolidBuilder to utilize its powerful features. The
SoftPlan Systems, Inc.
SoftPlan Architectural Design software is a residential
and light commercial CADD software package. SoftPlan
allows you to create floor plans, cross sections, elevations, framing plans, detail drawings, and site plans.
Drawings are assembled with features such as walls,
windows, doors, and beams. SoftView takes the drawing
created in SoftPlan and generates a 3D rendering of the
model. You can also create photorealistic interior and
exterior 3D renderings from any view.
106
Architectural Drafting and Design
CADD APPLICATIONS
The Future Is Here with CADD
CADD software programs offer a wide variety of applications
that make the design and drafting process efficient. Software
is the program or instructions that run the computer. One
example is a concept referred to as the Virtual Building.
With regard to computer usage, the term virtual refers to
something that appears to have the properties of a real or
actual object or experience. The Virtual Building stores your
work in a single building file where the information remains
integrated, up-to-date, and easy to manage. Working from
the Virtual Building file, you can create and modify buildings
in 2D and 3D views and easily create sections, elevations,
details, and other working drawings. Because the Virtual
Building is integrated, changes are automatically updated
in all views, saving time and reducing errors along the way.
Architects and designers can share their work directly
across a local network or the intranet and Internet. An
intranet links computers within a company or organization;
the Internet is a worldwide network of communication
between computers.
The Virtual Building allows coordination among the
activities and elements of a project as shown in Figure 7-1:
• Complete plans, sections, and elevations.
• Architectural and structural details.
• Window, door, and finish schedules with elevation
and plan symbols.
• Component lists with quality calculations for
estimating and building management.
• Photorealistic renderings for presentation and marketing.
• Virtual reality (VR) to show clients or to display on a
Web site. Virtual reality refers to a world that appears to
be a real or actual world, having many of the properties
of a real world. The VR world often appears and feels
so real that it almost is real. This is where the computer
is used to simulate environments, including the inside
and outside of buildings; sound; and touch.
• Walk-through or fly-through animation. Walk-through
can be described as a camera in a computer program
that is set up like a person walking through a building,
around a building, or through a landscape. Fly-through
is similar, but the camera is like a helicopter flying
over the area. Fly-through is generally not used to
describe a tour through a building. Walk-through or
FIGURE 71 The Virtual Building covers every facet of the architectural process of communication and collaboration. ArchiCAD Images. Courtesy Graphisoft.
Chapter 7: Computer-Aided Design and Drafting in Architecture
107
CADD APPLICATIONS
fly-through has the effect of a computer-generated
movie in which the computer images represent the
real architecture; or it is like a VR presentation in
which the computer images turn or move as you
turn your head in the desired direction. Realistic
renderings, animations, and VR are excellent tools for
PRODUCTIVITY WITH CADD
Users agree that CADD increases drafting productivity
over traditional manual drafting methods. Estimates
range from two times to ten times productivity increase
over manual drafting. In reality, any increase in productivity depends on the task, the system, and how quickly
employees learn to use CADD. Productivity is also
directly related to the amount of time a company has
had CADD in use, and to employee acceptance experience with the technology. Most companies can expect
more productivity after the users become comfortable
with the capabilities of the equipment and software.
For many duties, CADD does multiply productivity
several times. This is especially true of repetitious and
time-consuming tasks, which CADD performs much
faster and more accurately than manual techniques. A
great advantage of CADD is that it increases the time
available to designers and drafters for creativity by
reducing the time they spend on the actual preparation of drawings. A big increase in productivity over
manual drafting is when drawings are revised. CADD
makes the drawing revision process quick and easy.
Some of the business tasks related to architectural
design and drafting, such as analyzing construction
costs, writing specifications, computing, taking materials inventories, scheduling time, and storing information, are also done better and faster on a computer.
With some CADD systems, a designer can look at
several design alternatives at one time. The drafter
draws in layers; one layer can be the plan perimeter,
the next layer fixtures, the next electrical, and the
next dimensions and notes. Each layer appears in a
different color for easy comparison.
THE CADD WORKSTATION
This content provides information covering
the CADD hardware, ergonomics and ergonomic workstations, and positive work habits. Refer
showing a client how a building will look inside and
out. At this stage, design ideas can be created and
changes made easily.
• Sun studies for any location, date, and time.
• Reference drawings for sharing within the company
and for sharing with consultants in other companies. ■
to the Student CD: The CADD Workstation for more
information on CADD hardware and the CADD work
environment.
USING CADD TEMPLATES
A CADD template is a pattern of a standard or commonly used feature or features that is created once
and then used on following drawings. A collection of
symbols in a symbol library could be called a template.
If you create a base drawing that contains standard components, values, settings, borders, and title blocks, it is
referred to as a template drawing. Most schools and
companies use template drawings. Template drawings
save time and help produce consistency in the drawing process.
Template Drawing Contents
Template drawings should be stored in a common location that is accessible to everyone who needs them. This
is often on a network computer. If you maintain your
own templates, be sure they are stored in at least two
different locations for safekeeping. Template drawings
can and should be updated and added to periodically.
When updating a template, it is important that you
replace all old copies with the updated versions. Keep on
file a variety of template drawings that contain settings
for different drawing disciplines, drawing applications,
and scales. Template drawings can contain, but are not
limited to, the following items:
●
Border and title block with standard title block text
information completed if desired.
● Several named text styles with heights to match different scale drawings.
● Named dimension styles with values and settings for
specific drawing scales.
● Named layers containing colors, line types, and line
weights.
108
Architectural Drafting and Design
●
Display settings for point styles, line styles, and line
weights.
● User profiles containing display screen menu layouts,
colors, fonts, and configuration.
● Drafting settings, such as object snaps, grid, snap,
units, and limits.
● Section patterns (hatch) and scales.
● Plot styles and settings.
architectural and civil drafting templates are based on
appropriate architectural and civil drafting standards,
including standards specified in the U.S. National
CAD Standard.
Template drawings on the Student CD include the
following:
Template File
Application
ARCHITECTURALUS.dwt
Architectural draw- Architectural C size
ings dimensioned Architectural D size
in feet and inches.
ARCHITECTURALMETRIC.dwt
Architectural draw- Architectural A2 size
ings dimensioned Architectural A1 size
in metric units.
CIVIL-US.dwt
Civil drawings
dimensioned in
decimal inches.
Civil C size
CIVIL-METRIC.dwt Civil drawings
dimensioned in
metric units.
Civil A2 size
Using Template Drawings
Template drawings help you create new drawings by
referencing a base drawing that contains many of the
standard items required for multiple drawing projects.
Using template drawings is an easy process, and if a
standard procedure is followed, creates a productive
drawing session and ensures consistency in your drawings. Template drawings function and are used differently, depending on the CADD program. Many
programs provide convenient tools for referencing
stored drawing templates. This automates the traditional method of opening a template file and then saving
a copy of the template file using the name of the new
drawing. For example, AutoCAD software makes use of
drawing template (.dwt) files. Other CADD programs
have different but similar applications. Once you create
a .dwt file containing standard drawing settings and
objects, save the file in an easily accessible location and
create backup copies. When you are ready to prepare
a new drawing (.dwg) file, use the NEW command to
reference an existing .dwg file. A new drawing file
appears, with all the template file settings and contents.
Use the SAVE command immediately to save the drawing in the appropriate project file location and with
the desired name. The new drawing name is normally
related to the drawing type or project. Confirm this
with your school or company standards. You are now
ready to begin work on the new drawing project. As you
work, you may discover additional items that should
be included in your template drawings. When using
AutoCAD, for example, use the OPEN command to open
a .dwt file. Then add content to the file as needed. Once
you resave the file, the modified template is ready to use.
This leads to greater productivity in future work.
TEMPLATES DRAWINGS
ON THE STUDENT CD
The TEMPLATE DRAWING section of the
Student CD contains several predefined templates that
you can use to create drawings in accordance with
correct architectural and civil drafting standards. The
Layout Sheet Sizes
Civil D size
Civil A1 size
U.S. NATIONAL CAD STANDARD
In 1997, a group of agencies including the CADD/GIS
Technology Center (CGTC), the American Institute
of Architects (AIA), the Construction Specifications
Institute (CSI), the U.S. Coast Guard, the Sheet Metal
and Air Conditioning Contractors National Association
(SMACNA), and the National Institute of Building
Sciences (NIBS) came together to develop a single CADD
standard for the United States, now referred to as the
U.S. National CAD Standard (NCS). The NIBS Facility
Information Council (FIC) facilitated the development
of the NCS, and continues to support its advancement.
The development groups have agreed to maintain, revise,
and support the continued publication of the standard in
cooperation with the NIBS NCS Project Committee. This
cooperative agreement is unique in the architectural
design, construction, and computer industries.
The NCS is made up of three documents previously
published by member organizations of the FIC and a
report from the NIBS NCS Project Committee. The
NCS Project Committee report describes how the documents are related, resolves discrepancies between the
documents, and ensures the integration of previously
independent parts of the document. The previously
independent documents include:
●
The American Institute of Architects (AIA) CAD
Layer Guidelines.
● The Construction Specifications Institute (CSI)
Uniform Drawing System, Modules 1–8. Refer to
Chapter 8 of this textbook.
● The CSI Plotting Guidelines.
Chapter 7: Computer-Aided Design and Drafting in Architecture
109
Standards are very important in drafting. The purpose of the standard is to allow consistent and streamlined communication among owners, architects and
designers, and construction teams. Use of the standard
can result in reduced costs for developing and maintaining office standards and greater efficiency in the
transfer of building design information from design
to construction. The standard is not intended to be
applied with any specific CAD software program, but
AutoCAD and MicroStation were selected as the primary applications because of their popularity.
UNIFORM DRAWING SYSTEM
The Construction Specifications Institute (CSI) created the Uniform Drawing System (UDS) modules
consisting of standards, guidelines, and other tools for
organizing and presenting architectural information
that is used for the planning, design, construction,
and operation of facilities. The UDS was adopted by
the U.S. National CAD Standard. The UDS modules
are based on flexibility, consistency, and the linking of modules. UDS provides a framework for the
creation of a facility model that is represented using
drawings. The facility model is all information created that relates to a specific facility. Drawings store
and catalog information that is distributed through
the project cycle. A facility is a physical structure or
group of structures, including site construction, serving
one or more purposes. A project is a set of related
activities taking place at a facility and can include
planning, design and construction documents, consulting, purchasing, construction, and post-construction activities. The need for information contained
within drawings is different for each phase of a facility
or project cycle. Information in one cycle is normally
the basis for developing new information for the next
cycle. It is important for the drawings to be accurate
and organized in a way that makes them easy to find
and reuse. The project cycle is graphically presented
in Figure 7-2.
The basic content found in each UDS module is
as follows:
●
The Drawing Set Organization module covers
drawing units, file naming, and sheet identification. Drawing set organization establishes standard
discipline designators for each discipline, such as
A for Architectural, and establishes the order of
presentation of these disciplines within a drawing
set. CADD systems use real-world units for drafting with feet and inches, feet and tenths of feet,
and meters and millimeters as appropriate for the
Occupancy & Use of
Completed Project
5. Post-
1. Planning &
Construction
Activities
Predesign
Activities
Facility Management Documents
Operations & Maintenance Documents
Project Planning Documents
Marketing Materials
Planning & Programming Documents
Building and Site Assessment
Project
Identification
& Acquisition
4. Construction
Activities
2. Design
Modifications
Submittal Documents
Record Documents
Activities
Construction
3. Procurement
Activities
Addenda
Agency Approvals
Bidding/Negotiation/Purchasing
FIGURE 72 The project life cycle.
Sketches, Diagrams, & Schematics
Working Drawings
Perspectives and Renderings
Project
Development
110
specific drawing. File naming and sheet identification standards are described in detail later.
●
The Sheet Organization module establishes standards
for sheet sizes in the metric, or International System
of Units (SI), and the inch measurement systems. A
graphic layout divides the sheet into the drawing area,
the title block area, and note area. There is also a grid
system for organizing drawing information on a sheet.
The title block format includes content placement
locations, but allows flexibility for company design.
●
The Schedules module provides standard formats for
schedules used in construction documents, and has
an organizational system for identifying and filing
schedules. UDS schedules are described in detail in
Chapter 16, and specific discipline schedules, such
as electrical and plumbing, are described in their
related chapters.
●
The Drafting Conventions module addresses standard practices used on drawings, such as drawing
orientation, layout, symbols, material indications,
line types, dimensions, drawing scale, diagrams,
notation, and cross-referencing.
●
The Terms and Abbreviations module provides standard terms and abbreviations used in construction
documents and specifications. It provides consistent
spelling and terminology, standardizes abbreviations,
and notes common usage.
●
The Symbols module addresses commonly used
standard symbols, classifications, graphic representation, and organization in creating, understanding,
and fulfilling the intent of construction documents.
Standard symbols ensure clear and concise communication on drawings.
●
●
Architectural Drafting and Design
and the various drawing features on their own
layers as shown in Figure 7-3. A building model
is an electronic representation of a building, with
elements graphically representing the building
drawn with real-world size in their real-world units.
Real-world size and real-world units refer to true
size and full actual units. The sheet files bring the
model files together to create the composite drawing, and include the border and title block (see
Figure 7-3). CADD layers are covered in detail later
in this chapter.
Model File Names
Model file names are established in a standard format
based on the project code, the discipline designator,
the model file type, and the user definable code. The
project code is optional and is determined by the
designer or architect. The project code can have up
to 20 characters that are placed before the discipline
designator. The discipline designator has two characters, with the second character being a hyphen (-).
The first character of the discipline designator is one
of the following:
Discipline
Designator
General
G
Hazardous materials
H
Survey/Mapping
V
Geotechnical
B
Civil
C
The Notations module provides guidelines for note
classification, format, components, and location,
and includes the use of notes, terminology, and
linking drawing notes to specifications.
Landscape
L
Structural
S
Architectural
A
Interiors
I
The Code Conventions module identifies types of
general regulatory information that should appear
on drawings, locates code-related information in a set
of drawings, and provides standard graphic conventions. This module can be a tool to speed up code
review by designers and plan review authorities.
Equipment
Q
Fire protection
F
Plumbing
P
MODEL AND SHEET FILE-NAMING
STANDARDS
The model files contain the individual elements
that make up the final drawing of the building
model, such as the walls, doors, windows, dimensions,
Process
D
Mechanical
M
Electrical
E
Telecommunications
T
Resources
R
Other disciplines
X
Contractor/Shop drawings
Z
Operations
O
2
3
4
5
6
REVISION NUMBER:
7
E
E
DATE:
INITIALS
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Architectural
AutoCAD
12
6
12
6
D
D
C
C
Chapter 7: Computer-Aided Design and Drafting in Architecture
1
FRONT ELEVATION
B
1'-0"
1'-0"
21'-9"
17'-3"
10'-0"
4'-0"
1'-6"
1'-6"
9'-0"
21'-0"
4'-0"
1'-0"
B
1'-0"
9'-0"
17'-0"
4'-0"
10'-0"
21'-9"
17'-3"
10'-0"
2'-0"
1X8 TRIM
BOARD
1X6 TRIM
BOARD
12
6
CEDAR SHAKE
ROOF
12
6
1X8 TRIM
BOARD
TOP PLATE
TOP PLATE
1X6 HORIZ.
LAP SIDING
FLOOR LINE
COPYRIGHT ”
5'-9"
7'-0"
9'-1"
HEADER LINE
7'-0"
9'-1"
HEADER LINE
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER
SCALED DIMENSIONS. CONTACTOR SHALL ASSUME RESPONSIBILITY FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB. 3D-DZYN MUST BE NOTIFIED AND
CONSENT TO ANY VARIATION FROM DIMENSIONS SET FORTH HEREIN. ALL
IDEAS, DESIGNS, AND PLANS SET FORTH IN THESE DOCUMENTS ARE THE
ORIGINAL WORK-PRODUCT AND PROPERTY OF, AND OWNED BY 3D-DZYN.
THESE DOCUMENTS ARE FOR A SPECIFIED PROJECT OF THE PURCHASOR, ANY
REUSE OR REPRODUCTION OF SAID DOCUMENTS BY OTHER THAN 3D-DZYN IS
STRICTLY PROHIBITED BY LAW WITHOUT THE WRITTEN PERMISSION OF 3DDZYN.
1X4 CORNER
BOARDS
2003
1X8 TRIM
BOARD
FLOOR LINE
HOUSE EXERCISE
A
REAR ELEVATION
LEFT-SIDE ELEVATION
-
A
RIGHT-SIDE ELEVATION
FLOOR PLANS
PROJECT NUMBER:
ISSUED:
DRAWN BY:
CHECKED BY:
FILENAME:
RP2003-004
30APR03
RMP
RMP
A-FP01.DWG
A2.01
1
2
3
4
5
6
7
FIGURE 73 The sheet file brings the model files together to create the composite drawing, and includes the border and title block.
111
112
Architectural Drafting and Design
The model file type characterizes the type of drawing.
The following are model file types:
Code
Description
FP
Floor plan
SP
Site plan
DP
Demolition plan
QP
Equipment plan
XP
Existing plan
EL
Elevation
SC
Section
DT
Detail
SH
Schedule
3D
Isometric or 3D
DG
Diagram
The last four characters are user-definable such as
F1 for floor one. If all four characters are not used,
the remaining spaces are filled with Xs, for example
F1XX.
An example complete model file name is PR2010AFPF1XX.dwg, where:
●
PR2010 is the project code.
● A- is the discipline designator.
● FP is the model file type.
● F1XX is the user-definable code.
● .dwg is the AutoCAD drawing file extension.
MicroStation files use .dgn. Design Web format
files use .dwf. Drawing exchange files use .dxf.
Detail File Names
Detail files are a specific type of model file that
can include plans, elevations, sections, and details.
Detail files are placed on a sheet using sheet grid
coordinates (see Figure 7-5 on page 115). Sheet
grid coordinates are similar to zoning, described in
Chapter 4. The coordinates are a system of numbers
along the top and bottom margins and letters along
the left and right margins, allowing a drawing to
read like a road map. Detail file names are related to
the sheet file where they are located. The identification of details includes the drawing area coordinate
system, the sheet identification format, and a twopart reference bubble.
A reference bubble is a symbol placed below
the detail or section drawing used to designate the
origin of details and sections. The first five characters of a detail file name are identical to the identification of the sheet file where the detail is found.
This coordinates the detail file to the specific sheet.
The sixth character is the hyphen. The seventh and
eighth characters are used for the detail identification number.
A-201-B3.dwg is an example of a file name, where:
●
A-201 is the page where the detail is found.
●
B3 are the sheet grid coordinates where the detail
is found. This detail is located at the intersection of
coordinates B across and 3 up or down.
●
.dwg is the drawing file extension.
●
B3/A-201 is the two-part reference bubble for this
example detail.
Refer to the following sheet identification discussion
to learn how the detail file names relates to the sheet.
Library and Text File Names
Library files contain information for more than one
project, such as a commonly used detail, schedule,
text, database, symbol, border, and title block files.
Library file naming should be grouped by building
systems, assemblies, or usage for easy search reference. CSI MasterFormat and UniFormat numbers are
used for organizing library files. Refer to Chapter 8
for a detailed discussion on the CSI system. The
library file naming format includes three user-defined
characters after the MasterFormat or UniFormat
numbers, which are followed by a dot and the file
extension, such as .dgn, .dwg, or .dxf. An example is
040519XXX.dwg where:
●
040519 is the MasterFormat numbering system for
masonry anchorage and reinforcing.
●
XXX is a user identification.
●
.dwg is the file extension.
Similar to library files, text files are notes that can
be used on multiple projects, such as commonly used
general notes, discipline-specific notes, sheet-specific
notes, and standard symbol legends. An example text
file name is E-001-D.txt where:
●
E is the equipment category.
●
001 is the page where the note is found.
●
D is services.
●
.txt is the file extension that indicates this is a
text file.
Chapter 7: Computer-Aided Design and Drafting in Architecture
the sheet sequence number. For example, in the sheet
reference number A-124:
Sheet File Names
The purpose of a sheet file is to prepare information for
sheet setup. The format of the sheet file name should be
uniform with the sheet identification format.
SHEET IDENTIFICATION
Designator
General
0
Plans
1
Elevations
2
Sections
3
Large-scale views
4
Details
5
Schedules and diagrams
7
User-defined
3D
●
A- represents the architectural discipline.
● 124 indicates that 12 is the total number of sheets
and 4 is the specific sheet, such as sheet 4 of 12.
FILE MANAGEMENT
Sheet names are similar to file names, with the first one
or two characters being the discipline designator. A
level-one discipline designator uses one character. The
list of discipline designators is in the Model File Names
section earlier in this chapter. Level-two designators use
two characters for specific applications, such as AD for
“Architectural Demolition.” The discipline designator is
followed by a sheet-type designator, which is one of the
following numbers:
Sheet Type
113
Computer operating systems provide a tool that
allows you to create folders that are like the traditional
file folders found in the office file cabinet. The operating system is a master program that controls a computer’s basic functions and allows other programs to
access the computer’s resources such as the disk drive,
printer, keyboard, and screen. Folders, also known as
directories, on your computer allow you to store and
organize computer files. Without folders, your hard
drive can have thousands of separately named files
that would make it difficult or impossible to control.
Drawing and other construction document files are
saved in project folders and subfolders and are identified by name or number. A subfolder is a folder placed
inside another folder and contains files related to the
folder in which it resides.
Organizing Drawings and Construction
Documents
7 and 8
9
The sheet-type designator is followed by a twocharacter sheet sequence number, for example, 02-12.
Three more characters can be added for user-definable
content.
A sample sheet name is PR2004AD102XXX.dwg,
where:
●
PR2004 is the project code.
●
AD is the level-two discipline designator, Architectural Demolition.
●
1 is the sheet type.
●
02XXX is the sheet sequence number and userdefinable characters.
●
.dwg is the AutoCAD file extension (.dgn for a
MicroStation file).
The sheet identifier is located in the title block and in
any reference to the sheet on a drawing. Coordinating
between the sheet name and the sheet identifier are
the discipline designator, sheet-type designator, and
Drawing and construction document files must be
organized, so you or anyone else in the office can easily
find a drawing or document when needed. When
organizing files, create a project folder that contains
subfolders for each of the projects. The subfolders can
be named for the project, client, or job number. The
files in each project subfolder can include drawing
files, word processing documents, and spreadsheets
as needed. This helps keep the entire project together,
making it easier to manage. Figure 7-4 shows a file
structure for organizing drawing files.
SHEET ORGANIZATION
The NCS Sheet Organization module provides standards for consistent sheet format and a location system
for drawings on a sheet; it also establishes guidelines
for sheet management, note placement, and title block
content. Sheet organization standards are important,
because they improve communication among industry
professionals, improve drawing quality control, make
data management easier, and establish consistent sheet
organization appearance.
114
Architectural Drafting and Design
●
Project identification block: Project name and
location.
● Sheet identification block: The sheet identifier.
Root
Folder
C:
Projects
Sheet Sizes
.dwg files
Duplex
Movie
Theater
.dwg files
.dwg files
RP99-01
.dwg files
RP99-02
.dwg files
RP99-03
.dwg files
RP99-04
Recommended ANSI and ISO sheet sizes were discussed
in Chapter 4. The ANSI standard sheet sizes are generally used for inch drawings and the ISO sheet sizes are
used for metric drawings. Although the NCS does not
recommend specific sheet sizes, U.S. government agencies often require ANSI sheet sizes.
Sheet Layout
Sheets are divided into three main areas: drawing area,
title block area, and production data area. The drawing
area and title block area are required, but the production
data area is optional. The drawing and title block areas
are surrounded by border lines to outline and separate
the areas. Sheet margins are the spaces between the edge
of the sheet and the sheet area. The sheet margins vary
depending on plotter capabilities, sheet size, and sheet
area dimensions. The following are the recommended
minimum sheet margins:
●
.dwg files
RP00-01
.dwg files
RP00-02
FIGURE 74 A file structure for organizing drawing files.
Sheet Sizes, Borders, and Title Blocks
Sheet sizes, borders, and title blocks were discussed
and shown in Chapter 4. The standard recommends that title blocks be placed vertically along
the right side of the sheet and contain the following
compartments:
●
Designer identification block: The logo or name of
the agency or company.
● Issue block: Revision area or addenda.
● Management block: Information about the designer,
checker, and drafter.
Top and bottom margin: 3/4 inch (20 mm).
● Left margin: 1 1/2 inch (40 mm).
● Right margin: 3/4 inch (20 mm).
The Drawing Area Coordinate System
The drawing area coordinate system was introduced
in Chapter 4 with the discussion about zoning, and
again earlier in this chapter. Sheet grid coordinates are
like zoning, which is a system of numbers along the
top and bottom margins, and letters along the left and
right margins, allowing a drawing to read like a road
map. A goal of drawing layout is to organize drawing
areas in columns and rows. Columns are identified
with numerical characters starting with 1 and increasing to the right. Rows are identified with alphabetical
characters beginning at the bottom starting with A and
increasing toward the top of the sheet. Each drawing
module is identified by a letter and a number, such
as A1. Each drawing module is identified based on
the lower left corner location as shown in Figure 7-5.
Notice in Figure 7-5 that the drawing block labeled
A1 actually occupies several portions of the coordinate
system, but is identified by its location in the lower left
corner of the grid. A drawing can have one or more
drawing area modules.
Chapter 7: Computer-Aided Design and Drafting in Architecture
FIGURE 75 The drawing area coordinate system. Columns are identified with numerical characters starting with 1
and increasing to the right. Rows are identified with alphabetical characters beginning at the bottom starting with
A and increasing toward the top of the sheet. Each drawing module is identified by a letter and a number based on
the lower left corner location, such as A1. The note block is located in the far right column of the drawing area.
115
116
The Note Block
The note block is the module or modules within the
drawing area where keynotes, general notes, and key
plans are located. The note block is reserved for sheets
that have notes. The note block is located in the far right
column of the drawing area. A key plan block, when
used, should always be located in the lowest module of
the note block (see Figure 7-5).
SCHEDULES
A schedule is a grouping of related features or applications. Schedules format information in rows and columns to clearly provide design information. Schedules
can be developed as computer-generated databases or
spreadsheets, and can then be incorporated into drawings or specifications. Schedules can also have text and
symbols or diagrams as needed. The NCS recommends
schedules with uniform location, format, and information content for consistency and ease of use. Chapter 16
provides detailed information about the use of schedules
and shows the recommended NCS schedule format
options. Additional schedule information is provided
where schedules apply to specific content, such as electrical and plumbing.
DRAFTING CONVENTIONS
The following content provides specific information
about drafting conventions not covered in detail in
other chapters. The information provided throughout
this textbook relates to the NCS drafting conventions
where appropriate.
Drafting conventions provide a standard format for
graphic and text content on drawings. The NCS drafting
conventions include guidelines for consistent placement
of drawings, consistent orientation of dimensions related
to drawings, line representations, and drawing scales.
The NCS considers floor plans as the basis of drawing
documentation. Elevations, sections, and details are
developed from floor plans. Drawing standards provide
uniform guidelines for developing a set of construction
drawings of consistent quality and by avoiding duplicate
information. Drafting standards cover the drawing grid,
north arrow, recommended scales, line types, material
representation, and notes. Information covering these
standards is provided throughout this text as related to
specific applications. The orientation of the main floor
plan establishes the orientation of all other floors. Floor
plan orientation, the north symbol, and layout practices
are described in detail in Chapter 18.
Architectural Drafting and Design
Drawing Scales
The NCS defines scale as the ratio of measuring units
expressing a proportional relationship between a
drawing and the full-size item it represents. CADD
drawings are created at full scale and plotted at the
selected scale.
Proper scale selection determines the readability of
the drawing. The selected scale should be large enough
to allow the drawing to display its graphic, dimensional, and textual content clearly, without crowding.
For example, the detail of a windowsill can be drawn at
a 3" = 1'−0" (1:5 metric) scale to clearly identify the
features and dimensions. Scale selection is the responsibility of the designer or drafter. The example windowsill detail can be drawn using a smaller scale, if the
drawing content is still easy to read and the features are
clear. Some drawings have a specifically recommended
scale, such as floor plans that are typically drawn using
a 1/4" = 1'−0" (1:50 metric) scale.
Scale can be expressed numerically and graphically.
All drawings or views should indicate the numeric
scale, such as 1/4" = 1'−0" (1:50 metric). All drawings that may be reduced or enlarged should include
numeric and graphic scales, because the scale of the
reduced or enlarged drawing is no longer accurate. A
graphic scale is like a small ruler that represents the
numeric scale. The divisions on the graphic scale represent increments of measure that can be easily applied
to the drawing. The numeric and graphic scale, when
used, is generally placed below the drawing title as
shown in Figure 7-6.
Drawing scales were introduced in Chapter 3, and
they will be discussed in other chapters as related
to specific content. Recommended drawing scales
are also discussed in chapters where they relate to
the application, and may differ from the usual standard. The following combines the standard recommended scales for a variety of drawing types in inches
and metric:
MAIN FLOOR PLAN
SCALE: 1/4" = 1'–0"
NUMERIC SCALE
0
1
2
GRAPHIC SCALE
FIGURE 76 A drawing title with the numeric and graphic
scales provided.
5
Chapter 7: Computer-Aided Design and Drafting in Architecture
Drawing Type
Inch Scale
Metric Scale
Site plans
1" = 20"
1:200
1" = 30"
1:400
1" = 40"
1:500
1" = 50"
1:600
1" = 60"
1:700
1" = 100"
1:1000
1" = 200"
1:2000
1" = 400"
1:5000
1" = 500"
1:6000
1" = 1000"
1:10000
1" = 2000"
1:20000
1/4" = 1'−0"
1:50
1/8" = 1'−0"
1:100
1/4" = 1'−0"
1:50
1/8" = 1'−0"
1:100
1/4" = 1'−0"
1:50
1/8" = 1'−0"
1:100
1/4" = 1'−0"
1:50
1/8" = 1'−0"
1:100
1/4" = 1'−0"
1:50
1/8" = 1'−0"
1:100
1/2" = 1'−0"
1:25
3/4" = 1'−0"
1:15
1" = 1'−0"
1:10
1 1/2" = 1'−0"
1:8
1" = 1'−0"
1:10
1 1/2" = 1'−0"
1:8
3" = 1'−0"
1:5
Floor plans
Roof plans
Exterior elevations
Interior elevations
Full sections
Wall sections
Stair details
Details
117
Thus, the terms line thickness and line weight are used
interchangeably in CADD. A large variety of line
weights are possible, and the standard recommends
the following:
Line
Thickness Inches Millimeters Use
Extra fine
Thin
0.005
0.13
Fine detail.
0.007
0.18
Material patterns, section lines, hatch patterns.
0.010
0.25
Text: 3/32" to 3/8" (2.5 to
10 mm).
Dimensioning features,
phantom lines, hidden
lines, center lines, long
break lines, schedule
grid lines, background
objects.
Medium
0.014
0.35
Object lines, property
lines, text for notes and
in schedules, terminator
marks, door and window
elevations, schedule grid
accent lines.
Wide
0.020
0.50
Line Weights
Using a variety of line weights, or thicknesses, helps
improve drawing clarity. Certain features can be drawn
with thicker lines in an effort to make them stand out.
Text: 7/32" to 3/8" (6 to
10 mm).
Major object lines at
elevation edges, cutting-plane lines, short
break lines, title text,
border lines.
Extra wide
0.028
0.70
Text: 1/2" to 1" (13 to
25 mm).
Minor title underlines,
schedule outlines, large
titles, special emphasis
object lines, elevation
and section grade lines,
sheet borders, schedule
borders.
2× wide
0.040
1.00
Major title underlines,
separating portions of
a drawing.
3× wide
0.055
1.40
Border lines, cover sheet
lines, artwork.
4× wide
0.079
2.00
Border lines, cover sheet
lines.
CADD GRAPHICS
Architectural drafting is a graphic language made up
of features such as lines, symbols, and text. The NCS
standard provides recommendations for these drawing elements.
Text: 5/32" to 3/8" (4 to
10 mm).
Companies can use the range of NCS-recommended
line weights to provide accent to their drawings as
desired, or select a few of the line weights that correlate
best to their desired applications. This textbook recommends the following line weights, which are provided in
the architectural templates found on the Student CD:
118
Architectural Drafting and Design
Line
Thickness Inches Millimeters Use
Thin
0.010
0.25
Dimensioning features,
phantom lines, hidden
lines, center lines, long
break lines, schedule
grid lines, background
objects.
Medium
0.014
0.35
Object lines, text for
dimension values,
notes and in schedules,
terminator marks, door
and window elevations,
schedule grid accent
lines.
Wide
0.020
0.50
Major object lines at
elevation edges, cuttingplane lines, short break
lines, title text, minor
title underlines, border
lines.
Extra wide
0.028
0.70
Major title underlines,
schedule outlines, large
titles, special emphasis
object lines, elevation
and section grade lines,
property lines, sheet
borders, schedule
borders.
Line Types
Chapter 6 and throughout this textbook as related to
specific applications.
Dimensioning
Floor plan dimensioning is discussed in detail in
Chapter 17. The dimensioning standards and practices for other applications are covered in the chapters
where they correlate to the related content. Both feet
and inches and metric units are covered and related
to the standard.
Terms and Abbreviations
The NCS provides a complete listing of terms and
abbreviations used in architectural design and drafting,
and in the construction industry. The proper terms and
abbreviations are provided throughout this text where
they apply to specific content. Abbreviations should be
used to save time and drawing space.
Notes on Drawings
Drawing notes are introduced and covered in
Chapter 17, and notes for other applications are
covered in the chapters where they correlate to the
related content. The types of notes recommended by
the standard are:
A variety of line types are included in the standard. The
commonly used line types are introduced and shown
in Chapter 6, with examples of their applications.
Additional line type examples are provided throughout this textbook as related to specific applications.
●
Text Styles and Fonts
Architectural CADD Symbols
Text and text fonts are introduced and discussed in
Chapter 6. The NCS recommends using uppercase text
that is proportional and nonstylized. The standard suggests a SanSerif or similar font. Basic uniform fonts such
as RomanS or Arial are alternative font styles. These
fonts are very clear and easy to read, and can eliminate
the possible misunderstanding of drawing content.
CADD programs have a variety of fonts that comply
with NCS recommendations. Although not recommended by the NCS, CADD programs have fonts that
closely duplicate the artistic architectural style preferred
by some companies. Refer to Chapter 6 for more information. Recommended text heights are also covered in
CADD symbols are discussed and shown where they
apply to specific content throughout this textbook.
The standard provides a complete range of recommended symbols for all disciplines. The following is
a list of the classification of symbols by type:
General notes.
● General discipline notes.
● General sheet notes.
● Keynotes.
●
Reference symbols.
● Line symbols.
● Identity symbols.
● Object symbols.
● Material symbols.
● Text symbols.
Chapter 7: Computer-Aided Design and Drafting in Architecture
119
CADD APPLICATION
Architectural CADD Symbols
INTRODUCTION
Many companies have a manager who is responsible for
setting up the architectural CADD system and standards. This
person and the staff often create custom architectural CADD
menus and symbol libraries. The systems generally include
a custom screen and cursor, and pull-down, icon, and tablet
menus. Every time a new symbol or drawing detail is made, it
can be saved for future use. In this way, it is never necessary
to draw anything more than once with CADD. For example,
if a designer or drafter draws a structural detail, as shown in
Figure 7-7, this detail is saved for future use. A copy of the
symbol or detail is kept in a symbols manual, and information
about it is recorded for future reference.
Although every company saves symbols for future use,
many companies purchase their own core architectural
programs from a software developer. These are complete
architectural CADD programs that are ready to use out
of the box. These software programs provide commands
for the design and layout of walls, symbols, stairs, roofs,
structural grids, and plot plan symbols. Specific CADD
demonstrations are provided in the CADD Applications
features throughout this textbook.
AutoCAD, for example, has a powerful drawing
information manager called DesignCenter that allows
you to effectively reuse and share drawing content.
Drawing content is the variety of information in
the drawing, such as layers, layouts, line types, text
styles, and symbols. For example, you may want to
add the same common details, sections, architectural
symbols, and drawing layouts to numerous drawings.
DesignCenter lets you conveniently access drawing
24" CEDAR SHAKES
1Ø" EXPOSED
1 X 2 TRIM OVER 2 X 8
VERGE BOARD
RAFTERS
1'- Ø"
1/2" A-C EXT.
T PLLYW'D
SOFFIT
TYP
P. WALL
FRAMING
TYPICAL RAKE DETAIL
SCALE = 3/4" = 1'- Ø"
FIGURE 77 Drawing a structural detail on CADD and saving it
for future use. Courtesy Piercy & Barclay Designers, Inc., CPBD.
content and drag and drop it from one drawing to
another. Drag and drop is accomplished by picking an
item by positioning your cursor over it, pressing down
on the pick button, and holding it down. Then, still
holding down the pick button, drag the item to the
desired location. Finally, release the pick button to add
the information to the new area.
A number of sample drawing files are installed with
AutoCAD, and are available in the AutoCAD sample folders.
The Sample and DesignCenter folders contain numerous
different files, each with its own drawing content, such as
architectural symbol blocks. The content in each sample
file can be accessed in DesignCenter and dragged and
dropped into your drawing. Additionally, other symbol
libraries can be accessed through the DesignCenter Online
Web page using the DesignCenter’s DC Online tab. The
DesignCenter Online Web page allows you to download
drafting symbols from manufacturers and catalogs online,
which gives you access to a large number of architectural
symbols. Online refers to communicating with other
computers or with devices such as printers or file servers
through your modem or network.
In addition to DesignCenter, AutoCAD allows you to
insert frequently used drawing content from custom
storage spaces called tool palettes. Tool palettes are tabbed
areas in the Tool Palettes window used to store symbols
and hatch patterns for insertion into your drawings. You
can create a number of tool palettes with customized
settings. For example, you can store symbols with a variety
of different scale settings and object properties. Symbols
can easily be added to a tool palette from DesignCenter.
Most advanced software programs allow drawings
to be created as 2D or 3D and switched back and forth
at any time. These packages also let you render and animate 3D models. These 2D and 3D characteristics are
presented in CADD Applications features throughout
this textbook. Architectural software programs typically
have standard layer systems based on the American
Institute of Architects (AIA) format, which is described
later in this chapter.
DRAWING ARCHITECTURAL SYMBOLS
Symbols are drawn by selecting the desired symbol
from a menu. For example, if an exterior door is to be
drawn on a floor plan, the door symbol is selected from a
menu, the door symbol is dragged onto the screen with
the crosshairs, the door location is picked at the desired
insertion point with the crosshairs, and the desired
120
Architectural Drafting and Design
CADD APPLICATION
rotation is specified. Each symbol has an established
insertion point, as shown in Figure 7-8. Figure 7-9
shows an architectural floor plan, with text and its many
lines and symbols, drawn using CADD. Additional CADD
symbols are provided throughout this text where they
apply to specific content. The U.S. National CAD Standard
provides a full range of CADD-recommended symbols.
CREATING YOUR OWN CADD SYMBOLS
You can create your own CADD symbols if a customized
architectural menu is not available. The symbols that you
can make are called blocks, wblocks, or dynamic blocks
in AutoCAD. You can design an entire group of symbols
for inserting into architectural drawings. As you create
these symbols, prepare a symbols library or catalog,
where each symbol is represented for reference. The
symbol catalog should include the symbol name, the
insertion point, and other important information about
the symbol. Blocks are symbols that can be used within
a single drawing. Symbols that can be used in multiple
drawings are wblocks. Dynamic blocks are symbols to
which parameters and actions are assigned. A parameter
is a value that defines custom properties, such as
positions, distances, and angles for objects. An action
is a definition that controls how the parameters of a
dynamic block act. ■
DOOR
WINDOW
TUB
WATER
CLOSET
LAVATORY
SHOWER
DOUBLE
SINK
SPA
THIS SYMBOL
DISPLAYS THE
INSERTION POINT
FIGURE 78 Insertion points for several architectural symbols.
Using layers increases productivity in several ways:
DRAWING ON CADD LAYERS
Drawings are made in layers, each perfectly aligned with
the others. Each layer contains its own independent
information. Layers can be reproduced individually, in
combination, or together as one composite drawing.
Figure 7-10 shows how layers are used to share information among drawings.
●
Each layer can be assigned a different color, line type,
and line weight to correspond to line standards and
to help improve clarity.
●
Changes can be made to a layer easily, affecting all
objects drawn on the layer.
Chapter 7: Computer-Aided Design and Drafting in Architecture
121
CADD APPLICATIONS
FIGURE 79 Architectural floor plan with lines, symbols, and text, drawn using CADD. Courtesy Piercy & Barclay Designers, Inc., CPBD.
●
Selected layers can be turned off or frozen to decrease
the amount of information displayed on the screen or
to speed screen regeneration.
● Each layer can be plotted, or printed, in a different
color, line type, or line weight, or set not to plot at all.
●
Specific information can be grouped on separate layers.
For example, a floor plan can be drawn using specific
floor plan layers, the electrical plan on electrical layers,
and the plumbing plan on plumbing layers.
●
Several plot sheets can be created from the same
drawing file by controlling layer visibility to separate or combine drawing information. For example,
a floor plan and electrical plan can be reproduced
together and sent to an electrical contractor for a
122
Architectural Drafting and Design
Floor Plan
Drawing
Consolidated
CADD File
Reflected Clg.
Plan Drawing
Three word phrase
Labels
Labels L
to be is
used used
Label
Three word phrase
Labels L
to be is
used used
Label
Drawing Plans
Drawing Plans
12"
No measure lft. to rt. 7 ft.
48"
24"
Company name
Address of the local arch. office
No measure to rt. 7 ft.
12"
A–Z
No measure to rt. 5 ft.
Reflected Clg. Plan
Walls
Walls
Walls
Doors
Doors
Labels L
to be is
used used
Label
Three word phrase
Labels
Label
Labels L
to be is
used used
Drawing Plans
No measure to rt. 7 ft.
Label
Label
Drawing Plans
No measure lft. to rt. 7 ft.
48"
24"
Company name
Address of the local arch. office
12"
A–Z
Floor Plan Notes, Dimensions
24"
Company name
Address of the local arch. office
No measure lft. to rt. 7 ft.
48"
No measure to rt. 7 ft.
A–Z
Floor Plan Notes, Dimensions
Three word phrase
Three word phrase
Labels L
to be is
used used
Labels L
to be is
used used
Drawing Plans
12"
No reason to measure this part
24"
A–Z
Ceiling Grid
Three word phrase
Labels
Someones name
No measure lft. to rt. 5 ft.
48"
Floor Plan
Ceiling Grid
12"
No reason to measure this part
24"
Someones name
Drawing Plans
No measure lft. to rt. 5 ft.
48"
No measure to rt. 5 ft.
12"
A–Z
Clg. Plan Notes, Dimensions
No reason to measure this part
24"
Someones name
No measure lft. to rt. 5 ft.
48"
No measure to rt. 5 ft.
A–Z
Clg. Plan Notes, Dimensions
FIGURE 710 An example of using layers to share information.
bid. The floor plan and plumbing plan can be reproduced together and sent to a plumbing contractor.
CADD Layer Names
AIA recommends the use of layer names that contain
two to four parts. Refer to the AIA Standard, CAD Layer
Guidelines, or the U.S. National CAD Standard for complete information.
The layer name format is organized as a series of
ordered groupings. This organization allows you to
select from a variety of options for naming layers
according to the desired level of detailed information
you want to provide. Layer names consist of separate
groups of information, each separated by dashes (–).
The AIA CAD Layer Guidelines and the NCS provide
detailed lists of abbreviations, and codes for use in layer
names. Layer abbreviations and codes are designed to
be easily recognized and remembered as the intended
application. Because the NCS allows you to select from
a variety of format options for creating layer names,
it is recommended that you select the desired options
for a project, and then apply it consistently for all layer
names on that project.
The NCS-recommended layering system has a discipline designator, a major group, a minor group, and a
status field of information in the layer names.
The Discipline Designator
The discipline designator is a two-character field
identified by two letters followed by a hyphen. The
first letter is called the level-one discipline designator,
and the second letter is an optional modifier called
the level-two discipline designator. There are many
Chapter 7: Computer-Aided Design and Drafting in Architecture
discipline designator code combinations identified in
the standards. These are the common level-one discipline designator code letters:
123
There are many level-two discipline designators identified in Appendix A of the AIA CAD Layer Guidelines
and the NCS. Each level-one discipline designator has a
variety of level-two options. The following are the leveltwo options for the A (architectural) discipline:
Discipline
Description
A
Architectural
B
Geotechnical
C
Civil
D
Process
E
Electrical
F
Fire protection
G
General
H
Hazardous materials
I
Interiors
L
Landscape
M
Mechanical
O
Operations
The Major and Minor Groups
P
Plumbing
Q
Equipment
R
Resource
S
Structural
T
Telecommunications
V
Survey and mapping
X
Other disciplines
Z
Contractor and shop drawings
The major group is a four-character field that identifies
a major building system such as doors, windows, walls,
ceilings, furniture, or equipment. In the recommended
format, the major group is followed by a hyphen, and
then the minor group is used.
An optional four-character minor group field is used
to further define the major groups. A minor group
can be added to the layer name for further definition. Layers might have minor groups such as NOTE,
SYMB for symbols, DIMS for dimensions, or TITLB for
title block information. An example is AWALL-FULL,
which refers to Architectural (A), Wall, Full-height
(FULL). A second minor group can be used for further
layer description. An example using a second minor
group is, A-WALL-FULL TEXT, where the features
mean Architectural (A), Wall, Full-height (FULL), Text.
Minor group code abbreviations are logically grouped
in the standard with specific major groups. However,
any minor group can be used with any major group,
but the definition of the minor group must remain
unchanged. This provides you with flexibility, because
any reasonable combination of the major and minor
groups is permitted.
The use of discipline designators can depend on the
office where the drawings are created. For example, if
an architectural office creates all of the drawings for
a complete set of working drawings, then the A discipline designator can be used to indicate the origin of
all drawings as architectural. A more likely example is
where the architectural office creates the base drawings, such as the floor plan designs, and then sends
the base drawings to consultants who create the discipline-specific drawings such as electrical, plumbing,
and mechanical. The consulting offices then use the
discipline designators that relate to their drawing disciplines, such as E for electrical, P for plumbing, and
M for mechanical. This practice can also be used in
the architectural office that creates all the drawings for
the complete set of working drawings. In this case the
office correlates each layer name with the discipline
that the layer identifies, such as E for electrical, P for
plumbing, and M for mechanical. The layer names
identified throughout this textbook are coordinated
by discipline as in the last two examples.
Designator
Description
AD
Architectural Demolition
AE
Architectural Elements
AF
Architectural Finishes
AG
Architectural Graphics
AI
Architectural Interiors
AJ
User-Defined
AK
User-Defined
AS
Architectural Site
The Status Field
The status field is an optional single-character field
that identifies the information on the layer according
to the status of the work or the construction phase
of the project. These status entries are for special
project requirements that relate to new and existing
construction in remodeling projects. The following
are the status field codes:
124
Architectural Drafting and Design
Code
Description
Discipline Designator
D
Existing to demolish
E
Existing to remain
F
Future work
M
Items to be moved
N
New work
T
Temporary work
X
Not in contract
1–9
Phase numbers
Major Group
A
A
-
W
A
L
L
Discipline Designator – Level 1
Discipline Designator – Level 2
Major Group
B
A
D
-
W
A
L
L
FIGURE 711 Examples of the U.S. National CAD Standard
layer name format. (A) The required discipline designator and
major group fields. (B) The required level-one discipline designator and major group fields, with the optional level-two discipline designator.
Combining the Layer Name Elements
Figure 7-11 shows examples of the U.S. National CAD
Standard layer name format with the discipline designator and major group. Figure 7-12 shows examples
of the U.S. National CAD Standard layer name format
from discipline designator to status code.
The recommended NCS layer names are too
numerous to display in this textbook. However, each
chapter provides recommended NCS layer names
that relate to the layers used in the chapter content.
architect often creates the building design and has
others design the electrical, plumbing, and mechanical systems. The mechanical system encompasses
heating, ventilating, and air conditioning. To make
this system work effectively, the architect prepares a
base drawing, which represents the floor plan and its
bearing walls and partitions as shown in Figure 7-13.
The file is sent to the interior design department
or consultant to create the layers containing the
nonbearing facility layout, which can include the
room layout with fixtures and appliances as shown
in Figure 7-14. The CADD drawing files then go to
the plumbing, electrical, and mechanical contractors
Using CADD Layers
A big advantage of CADD is the ability to send drawing files on disk or through the Internet or an intranet
to different subcontractors involved in a project. This
is important in commercial applications because the
Discipline Designator
Major Group
Minor Group
A
A
-
W
A
L
L
-
F
U
L
L
Discipline Designator
Major Group
B
A
-
W
A
L
L
-
Minor Group
F
U
Discipline Designator – Level 2
Major Group
C
A
-
W
A
L
L
-
F
L
L
-
Second Minor Group
T
E
Minor Group
U
L
L
-
X
T
Second Minor Group
Status Code
T
E
X
T
-
N
FIGURE 712 Examples of the U.S. National CAD Standard layer name format. (A) The discipline
designator, major group, and minor group fields. (B) The discipline designator, major group,
minor group, and second minor group fields. (C) The discipline designator, major group, minor
group, second minor group, and the status code.
Chapter 7: Computer-Aided Design and Drafting in Architecture
125
FIGURE 713 Base layer sheet for exterior and support structure is unchanged through the project. Courtesy Structureform.
for design of their related construction drawings.
Figure 7-15 shows the plumbing layer for the building
used in this example. A composite drawing of all layers
is shown in Figure 7-16. Each layer is set up in its own
color and is displayed in color on the computer screen.
CADD PLOTTING GUIDELINES
A drawing created in CADD exists in two forms: soft
copy and hard copy. Soft copy is the computer software
version of the drawing that you see on the computer
screen, or the actual data file. Hard copy, as introduced
earlier, is a physical drawing produced on paper or
some other medium by a printer or plotter.
Scale Factors
A scale factor is a numeric value that is used in the
proper scaling of text, and dimension objects, such as
dimension text and arrowheads or slashes, and the size
of the model limits. When drawing in CADD, the objects
FIGURE 714 Interior design of nonbearing partitions may be changed as desired using layers. Courtesy Structureform.
126
Architectural Drafting and Design
co
3/4"␾
10 GAL ELEC W.H.
co
1/2"
co
1/2"
1/2"
2"␾
1/2"␾
3"␾
1/2"
co
2"vent 1/2"␾
2"␾
1/2"␾
1/2"␾
1/2"␾
w
w
s
w
s
s
s
1/2"␾
1/2"␾
w
co
2"␾
w
3"␾
1"␾
2"␾
co
1/2"
3/4"␾
1/4"
1/2"␾
10 GAL ELEC W.H.
s
3"␾
3/4"␾
co
1/4"␾
2"␾
1/2"
1/2"␾
co
1/2"␾
1/2"
= EXIST. 4"␾ C.I. SEWER LINE
s
w
= NEW C.I. SEWER LINE
= EXIST. 1"␾ WATER LINE
w
= NEW WATER LINE
= NEW 10 GALLON
ELECTRIC WATER HEATER
OVER RESTROOM ON
PLATFORM. WATER HEATER
TO BE AMERICAN APPLIANCE
4 GSM 10 OR EQUAL AS LISTED
IN THE DIRECTORY OF
CERTIFIED WATER HEATERS
BY THE CALIFORNIA ENERGY
COMMISSION (NOTE: PROVIDE
3/4" + COPPER P+T VALVE
DISCHARGE LINE TO OUTSIDE
FOR EACH WATER HEATER).
FIGURE 715 Plumbing layer. Courtesy Structureform.
co
3/4"f
w
10 GAL ELEC W.H.
co
2"vent 1/2"f
1/2"
co
2"f
1/2"f
3"f
1/2"
co
1/2"f
2"f
1/2"f
1/2"f
s
w
w
s
s
1/2"f
w
co
s
1/2"f
3"f
3/4"f
3"f
1"f
2"f
co
1/2"
3/4"f
10 GAL ELEC W.H.
1/2"f
co
1/2"f
1/2"
w
co
w
1/4"
s
2"f
1/4"f
2"f
1/2"
1/2"f
= EXIST. 4"f C.I. SEWER LINE
w
= NEW C.I. SEWER LINE
= EXIST. 1"f WATER LINE
= NEW WATER LINE
1/2"
1/2"
s
FIGURE 716 Composite of base layer, interior design layer, and overlays. Courtesy Structureform.
= NEW 10 GALLON
ELECTRIC WATER HEATER
OVER RESTROOM ON
PLATFORM. WATER HEATER
TO BE AMERICAN APPLIANCE
4 GSM 10 OR EQUAL AS LISTED
IN THE DIRECTORY OF
CERTIFIED WATER HEATERS
BY THE CALIFORNIA ENERGY
COMMISSION (NOTE: PROVIDE
3/4" + COPPER P+T VALVE
DISCHARGE LINE TO OUTSIDE
FOR EACH WATER HEATER).
Chapter 7: Computer-Aided Design and Drafting in Architecture
are always full scale. For example, a 50'−0" × 30'−0"
(15,240 × 9,144 mm) building is drawn 50' × 30'.
After the building is drawn, the notes and other text
are added. If you use standard text height, then the text
needs to be plotted 1/8" (3 mm) high on the drawing. If
1/8" text is placed on the 50' × 30' building, the text on
the computer screen and on the plot is too small to read.
This is where the scale factor becomes important.
The scale factor of a drawing is something that you
need to plan in advance and is part of your CADD
template. As discussed earlier, a template is a file
containing standard settings such as layer names,
dimension and text styles, and line types applied to
the drawing. To make the text readable on the plotted
paper, the desired plotted text height of 1/8" is multiplied by the scale factor, to determine the height of
the text when in the drawing. The scale factor is also
used to scale dimension features.
To determine the scale factor, first decide on the drawing scale for the plotted drawing. The scale factor is then
determined by dividing the plotted units into the drawing
units. The following formula demonstrates this concept:
Plotted Units = Drawing Units
Plotted Units Drawing Units = Scale Factor
An architectural drawing to be plotted at 1/4" = 1'−0"
has a scale factor calculated like this:
1/4" = 1'−0"
.25" = 12"
12/.25" = 48"
The scale factor is 48.
Once the scale factor has been determined, calculate
the actual text height to be used in the CADD program.
If the desired text height is 1/8", multiply the plotted
text height by the scale factor. So, for the 1/4" = 1'−0"
scale drawing, the text height is:
1/8" × 48" = 6"
1/8" high text on the 1/4" = 1'−0" scale plotted
drawing is drawn at 6" high
Model and Sheet Layout
Earlier in the standards discussion, you learned that
CADD files are created as models and sheets. AutoCAD,
for example, refers to the place where drawing objects
are created as model space, and sheet space is called
layout space. Layout space is an area used to lay out
the sheet of paper to be plotted. Everything you draw
in CADD is drawn full scale in model space. When
you enter layout (sheet) space, a real-size sheet of paper
127
is placed over the top of the model space drawing.
Border lines, title blocks, and notes are also found on
the real-size paper layout space. The model space drawings and the layout space sheet are put together for
plotting. In Figure 7-17, the drawing in model space
is combined with the layout space sheet. When setting
up the drawing to be plotted, multiple models can be
arranged on the layout space sheet. For example, a
foundation sheet can have the foundation plan at one
scale and separate details at another scale as shown in
Figure 7-18.
Getting Ready to Plot
When the layout is prepared as desired, the sheet
can be set up for plotting. During this process you
can select plotter settings, pen settings, and paper
size. Each layout can have a unique sheet setup. For
example, you can create two layouts for a floor plan.
One layout can be assigned a 36 × 24" sheet size and
another can be assigned an 8 1/2 × 11" sheet size. This
allows you to maximize the plotting possibilities with
the same drawing. Your CADD program has a sheet or
page setup dialog box or menu where plotter configurations can be selected. Plotters are displayed on the list
of devices if you use the Microsoft Windows operating
system where printers and plotters are configured.
After the plotter is selected, you can specify the
desired pen settings. To do this, a plot style table
can be assigned to the layout. A plot style table is a
pen configuration that allows you to have complete
control over how your drawing appears when plotted.
Two common plot style tables are the color table and
the style table. Color tables assign different pen values
to the colors in the CADD program. For example, if
the color red is assigned a heavyweight pen that plots
with a black color, then any objects with a red color
are plotted with heavy black lines. Style tables are
names with pen settings that can be assigned to layers
or objects. For example, a style table can include a
named style called Walls, which has been assigned
a heavy black line. The Walls pen style can then be
assigned to the Wall layer in the drawing. Anything
that is drawn on the Wall layer then plots with a
heavy black line. After the desired plot style table is set
up, you are ready to send the drawing to the plotter.
Standard applications of line weights and colors were
discussed earlier in this chapter. Line weights are also
covered in Chapter 6 and throughout this book where
they apply to specific drawing features. Additionally,
the NCS provides information and settings for black,
white, and gray plotting, line weight plotting, and
color plotting. There are likely more settings required
for your specific CADD program, such as AutoCAD
128
Architectural Drafting and Design
MODEL SPACE DRAWING
SCALED IN LAYOUT
SPACE VIEWPORT
VIEWPORT CUT
INTO PAPER
DRAWING IN
MODEL SPACE
(FULL SCALE)
REAL-SIZE PAPER
IN LAYOUT SPACE
FIGURE 717 The drawing in model space being combined with the layout space sheet.
FIGURE 718 A foundation sheet with the foundation plan at one scale and separate details at another scale ready to be plotted.
Chapter 7: Computer-Aided Design and Drafting in Architecture
or MicroStation. Carefully review the users’ guide,
Help files, or an in-depth textbook correlated to your
CADD software for detailed information.
Plotting to a File
It is also possible to plot your drawing to an electronic
file. This is often done to allow your drawing to be
published to the Internet and viewed through a Web
browser. The file type for this application is DWF,
which stands for drawing Web format. One advantage
of plotting files to a DWF format is that the drawings
129
can be shared by another person who does not physically have the CADD program to view the drawings.
For others to view your CADD drawings in this
manner, they need a DWF Viewer program. This is a
free viewer available from the Autodesk Web site. No
major programs, such as Microsoft Word, can open a
DWF file. Other advantages are that drawings cannot
be edited, and this provides a great means for archiving
projects, because the actual drawing files do not have to
be opened and viewed from the CADD program. The
DWF files are also considerably smaller in size and can
be easily sent through e-mail.
CADD APPLICATIONS
This Is What the Future Looks Like: Web-Based Architectural Collaboration
Architecture is beginning to see the development of
technologies that allow teamwork over the World Wide
Web (WWW). This technology has major implications
for the evolution of the practice. Architecture is a
cooperative process involving multiple disciplines such
as structural, mechanical, and electrical engineering;
interior design; and facility management. One of the
most time-consuming and risky aspects of the practice
is document management. Hundreds of drawings and
documents can be issued during the design process.
All of these documents can be in various states of
completion. The coordination of this information is a
big task. Web-based coordination uses the power of
advanced database management systems together
with the Internet to simplify and streamline document
management and team communications. These products
allow architects, designers, drafters, product suppliers,
building contractors, and owners to communicate and
coordinate throughout the entire project regardless of
where each team member is located.
This changing technology also has applications for
the way design projects are produced. Web-based
coordination allows for the increased use of outsourcing.
Outsourcing means sending parts of a project out
to subcontractors for completion. Outsourcing to
multiple resources requires consistency in procedure
and similarity in tools. This interactive teamwork of the
future requires clear measurement of progress. The
collaboration tools now being developed give architects
a higher level of communication and control over the
production process. E-mail allows tracking throughout
the project. The outsourcing model of the future is
based on defined tasks rather than hours worked. These
separate tasks are based on interrelated logical steps
rather than drawing sheets. Drawings move forward on
the basis of their relationship to other drawings and the
available information. The development of drawings
and documents is treated as stepped tasks or slices of
time. Outsource personnel are independent contractors
responsible for managing their own time rather than
punching a clock. These professional subcontractors
are found all over the world, and they are connected
through the Web. Through this huge network of
potential workers, it is possible to find professionals
who produce high-quality drawings economically and
on schedule.
Web-based collaboration also affects the relationship
of the architect and the client. Because the work product
is visible on the Internet, the owner can view progress
at any time. Progress on the documents is obvious,
and the owner can involve more people in reviewing
the work. This model of practice improves the owner’s
involvement in the process and increases the sense of
overall teamwork. ■
130
GOING
GREEN
Sustainable Design Opportunity
INTRODUCTION
According to the U.S. Green Building Council (http://
www.documents.dgs.ca.gov/dgs/pio/facts/LA%20
workshop/climate.pdf), buildings alone account for a
sizable amount of global greenhouse gas emissions,
representing 39% of CO2 emissions in the United States.
This is primarily due to energy use, as buildings consume
76% of all power plant–generated electricity, according
to the U.S. Energy Information Administration (http://
www.architecture2030.org/current_situation/building_
sector.html). Increasingly, voluntary goals, such as the
AIA 2030 Challenge to achieve carbon-neutral buildings
by 2030, are becoming regulatory requirements like the
U.S. federal law that requires a 55% fossil fuel reduction
by 2010 and carbon neutrality by 2030 for all new federal
buildings. Improving building energy performance by
employing sustainable design principles presents an
enormous opportunity for innovative Architectural,
Engineering, and Construction (AEC) practices. Building
professionals can dramatically reduce the negative
environmental impact of new and renovated buildings.
SUSTAINABLE DESIGN IN PRACTICE
The world is changing, the economy is changing,
and architectural practice is changing. Designing and
delivering more sustainable projects can be complex.
It requires close coordination across different project
stages, from design through construction and operation.
Many firms are looking for the best way to integrate
building information modeling (BIM) technology with
sustainable design and analysis tools.
BIM is an integrated workflow built on coordinated,
reliable information about a project from design
through construction and into operations. With BIM, the
information required for sustainable design analysis,
code compliance, and certification becomes available as
a by-product of the standard design process, making the
sustainable design process inherently more efficient and
cost effective.
ANALYSIS FOR SUSTAINABLE DESIGN
Everything in the built environment is sustained by
energy, water, and materials. Design decisions made
early in the process can deliver significant results when
it comes to the efficient use of these vital resources.
Analysis tools for sustainable design enable significant
impact on the efficient use of energy, water, and
materials in a building design. These tools:
• Empower users to be experts quickly.
• Consider the whole building system.
• Deliver powerful analysis from immense stores
of data.
• Interpret results in a meaningful way.
• Enable iteration for improvement.
Sustainable Energy Use
Buildings consume energy throughout their life cycle—
from the energy used to create the building materials,
to the heating, cooling, lighting, and ventilation systems
used during building operation, and the equipment used
by the occupants for movement, such as elevators; and
various processes, such as business equipment. From
a sustainable building perspective, once a project is
complete it should remain in use for a very long time.
Think centuries. Given this time frame, the operational
energy of most buildings will be many times greater than
that required for the initial construction or renovations.
Therefore, to achieve sustainable energy use, a building’s
total operating energy must first be minimized and
then rely on renewable forms of energy to meet its total
operating requirements.
Sustainable Water Use
Similar to energy, a building’s initial construction
and renovations use a much smaller portion of water
compared to its operational use over its life. The water
uses in the building include requirements for occupant
potable and nonpotable needs, heat, ventilation, airconditioning (HVAC) systems, and other processes. To
achieve sustainable water use in a building, its use must
first be minimized, then seek reclaimed and renewable
sources. The primary renewable source for water is
rainwater catchment, either natural as in surface water
or groundwater or human collected using cisterns.
Sustainable Material Use
The construction of a building or other structure
requires a significant amount of raw and manufactured
materials, such as wood, metal, plastics and minerals
for the structure and finishes, wiring, duct work, and
other system components, including fittings, finishes,
equipment, various adhesives, gypsum board, glass, concrete, and masonry products. The vast majority of the
materials used are nonrenewable, so from the start,
the project design should have a very long life in mind.
The next step is to select materials that are appropriate
for the development and benefit its energy and water
use minimization goals. If reliable data are available,
identify sources for materials that have low manufacture,
supply, and transportation energy and emissions requirements, and minimum toxic by-products.
Architects and engineers can use digital design
information to analyze and understand how their
projects perform before they are built. Developing
and evaluating multiple alternatives at the same time
GOING
GREEN
131
Sustainable Design Opportunity (Continued)
allows easy comparison and informs better sustainable
design decisions. BIM is core to Autodesk’s sustainable
design approach for building performance analysis and
simulation.
For example, with Autodesk Green Building Studio Web
service, architects and designers can easily perform wholebuilding energy, water, and carbon-emission analysis, and
evaluate the energy profiles and carbon footprints of various
building designs. Autodesk Ecotect software measures how
the environment will affect building performance. The 3D
conceptual analysis tools within Ecotect allow architects and
engineers to simulate and analyze, in the conceptual and
design phases, how factors such as solar, shading, lighting,
and airflow will affect how a building design will operate
and perform. Figure 7-19 shows shading analysis at
work, and Figure 7-20 shows the result of airflow analysis.
For most building projects, decisions made in the
first few weeks of the design end up having the greatest
impact on a building’s performance. The location of the
building on the site, its basic form and orientation, its
internal layout and external materials selection, its exterior
openings—all of these factors are set very early in the
design process. As soon as the layout of a building’s
walls, windows, roofs, floors, and interior partitions
(elements that define a building’s thermal zones) are
established, a model is ready for whole-building analyses.
A computable Autodesk Revit design model is a great fit
for the analyses needed.
ANALYZING A BUILDING DESIGN
The Autodesk Green Building Studio Web service delivers
the ability to exchange and use information between
building designs and advanced energy analysis software
programs such as DOE-2, allowing analyses of a building
model to be performed by architects, from within their
own design environment, directly over the Internet.
DOE-2 is an energy modeling program that provides
different approaches for defining the building geometry.
This streamlines the entire analysis process and allows
architects to get immediate feedback on their design
alternatives—making green design more efficient and
cost effective.
FIGURE 719 An example of shading analysis at work. Courtesy Autodesk, Inc.
132
GOING
GREEN
Sustainable Design Opportunity (Continued)
FIGURE 720 The result of airflow analysis. Courtesy Autodesk, Inc.
Based on the building’s size, type, and location, which
drive electricity and water usage costs, the Green Building
Studio Web service determines the appropriate material,
construction, system, and equipment defaults by using
regional building standards and codes to make intelligent
assumptions. Using simple drop-down menus, shown
in Figure 7-21, architects can quickly change any of
these settings to define specific aspects of their design:
a different building orientation, a lower U-value window
glazing, or a 4-pipe fan coil HVAC system, for example.
The Web service uses precise hourly weather data, as
well as historical rain data, that are accurate to within
9 miles of any given building site. It also uses emission
data for every electric power plant in the United States
and includes the broad range of variables needed to
assess carbon neutrality.
The software determines a building’s carbon
emissions and the architect views the output in a Web
browser, including the estimated energy and cost
summaries as well as the building’s carbon-neutral
potential. Architects can then explore design alternatives
by updating the settings used by the Web service and
rerunning the analysis, and/or revising the building
model itself in Revit and then rerunning the analysis.
The output also:
•
•
•
•
•
Summarizes water usage and costs.
Summarizes electricity and fuel costs.
Calculates an Energy Star score.
Estimates photovoltaic and wind energy potential.
Calculates points toward Leadership in Energy and
Environmental Design (LEED) daylighting credit.
• Estimates natural ventilation potential.
The Autodesk Green Building Studio report is very
easy to understand, giving architects the actionable
information they need to make greener design decisions.
Autodesk Ecotect software, built specifically by
architects that focuses on the building design process,
is an analysis tool that allows designers to simulate a
wide array of environmental factors—such as shadows,
shading, solar, lighting, thermal, ventilation, and
acoustics—with a highly visual and interactive display
GOING
GREEN
133
Sustainable Design Opportunity (Continued)
FIGURE 721 Using the Green Building Studio drop-down menus, architects can quickly change any of these
settings to define specific aspects of their design: a different building orientation, a lower U-value window
glazing, or a 4-pipe fan coil HVAC system. Courtesy Autodesk, Inc.
that presents analytical results directly within the
context of the building model. This visual feedback
allows the software to communicate complex concepts
and extensive datasets, and helps designers engage
with comprehensive performance issues early in the
schematic phase when designs can be changed easily.
Revit-based design models can be imported directly
into Autodesk Ecotect for analysis throughout the design
process. At the start of the design process, early-stage
massing models can be used in combination with the site
analysis functionality to determine the optimal location,
shape, and orientation of a building design based on
fundamental environmental factors such as daylight,
overshadowing, solar access, and visual impact.
As the conceptual design evolves, whole-building
energy solutions, such as Green Building Studio, can be
used to benchmark its energy use and recommend areas
of potential savings. Once these fundamental design
parameters have been established, Ecotect can be used
again to rearrange rooms and zones, to size and shape
individual openings, to design custom shading devices
or to choose specific materials based on environmental
factors such as daylight availability, glare protection,
outside views, and acoustic comfort.
Autodesk Ecotect provides the ability to act on
feedback to the designer in the form of visual and
interactive displays, which are more than just charts and
graphs. The analysis results are presented directly within
the context of the model display: shadow animations
resulting from shadow casting analysis, surface mapped
information such as incident solar radiation, and
spatial volume-related renderings such as daylight or
thermal comfort distribution in a room. Surface mapped
information is data, such as lighting levels, shading, or
shadowing, mapped over building surfaces.
Incident solar radiation is the amount of energy
falling on a flat surface. It is not affected in any way by
the surface properties of materials or by any internal
refractive effects; it is concerned only with the radiation
actually striking the surface. Spatial volume-related
renderings are 3D visualizations that help to identify the
spatial relationships between different zones. Figure 7-22
shows incident solar radiation analysis at work.
This type of visual feedback lets designers more easily
understand and interact with analysis data, often in real
time. For instance, a designer can rotate a view of solar
radiation looking for variations over each surface, or
watch an animated sequence of solar rays to see how
sunlight interacts with a specially designed light-shelf at
different times of the year, as shown in Figure 7-23.
During conceptual design, Autodesk Ecotect can be
used for a variety of early analyses. For example, the
designer can perform overshadowing, solar access, and
wind-flow analyses to repeat on a form and orientation
that maximizes building performance without infringing
on the rights-to-light of neighboring structures.
As the design progresses and the elements that define
a building’s thermal zones are established (the layout of
the walls, windows, roofs, floors, and interior partitions),
the model can be used for room-based calculations such
as average daylight factors, reverberation times, and
portions of the floor area with direct views outside.
134
GOING
GREEN
Sustainable Design Opportunity (Continued)
FIGURE 722 Incident solar radiation analysis at work. Courtesy Autodesk, Inc.
FIGURE 723 An animated sequence of solar rays to see how sunlight interacts with a specially designed
light-shelf at different times of the year. Courtesy Autodesk, Inc.
135
GOING
GREEN
Sustainable Design Opportunity (Continued)
SUMMARY
The consistent, computable data that come from
a BIM workflow, combined with the breadth of
performance analysis and meaningful feedback
of Autodesk Green Building Studio and Autodesk
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you find information related to computer-aided
design and drafting and keep current with trends in the
industry.
Address
www.aia.org
www.autodesk.com
www.bentley.com
www.digitalcanal.com
www.graphisoft.com
www.sketchup.com
Ecotect, provide a complete approach that architects
can use to simulate and analyze designs. This
feedback, especially during early conceptual design,
is critical for architects to optimize the performance
of their building designs.
Company, Product,
or Service
American Institute of
Architects
Architectural software
Architectural software
Architectural software
Architectural software
Architectural software
www.softplan.com
www.csinet.org
www.nahb.org
Architectural software
Construction Specifications
Institute
National Association of
Home Builders
www.buildingsmartalliance.org/ncs
National Institute of
Building Sciences Initiative
https://cadbim.usace.army.mil Order a CD of the A/E/C
CADD Standard from the
CADD/GIS Technology
Center
www.nationalcadstandard.org U.S. National CAD Standard
ordering information
Computer-Aided Design and Drafting
in Architecture Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 7 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 7–4 Describe how drawing layers can be
prepared on a computer graphics system.
Question 7–5 Describe three ways architectural design
functions are improved with a CADD system.
Question 7–6 Describe three potential disadvantages
of CADD.
Question 7–7 What does WWW stand for?
Question 7–8 Define outsourcing.
Question 7–1 What does the abbreviation CADD mean?
Question 7–9 Define virtual reality.
Question 7–2 Identify three factors that influence an
increase in productivity with CADD.
Question 7–10 Explain the difference between an
intranet and the Internet.
Question 7–3 Identify five tasks, not related to drafting,
that can be performed by a computer.
Question 7–11 Discuss the similarities and difference
between walk-through and fly-through.
136
Architectural Drafting and Design
Question 7–12 What is a scale factor?
r. Windows
Question 7–13 Give a sample U.S. National CAD
Standard file name and label its parts.
s. Attribute
Question 7–14 Give a sample U.S. National CAD
Standard sheet name and label its parts.
u. Optical mouse
Question 7–15 Define template.
Question 7–16 Calculate the scale factor for an
architectural drawing to be plotted at 1/4" = 1'−0", and
determine the height of 1/8" plotted text at this scale.
Question 7–17 Define model space and layout space.
t. Font
v. Facsimile
w. Resolution
x. Text
y. Layers
z. Backup
Question 7–18 Give a sample U.S. National CAD
Standard layer name, providing the maximum number
of fields, and label its parts.
Question CD7–5 Name the most common type
of injury that can develop at a poorly designed
workstation.
Question 7–19 Define drawing content.
Question CD7–6 Identify at least three factors related
to positive work habits that can contribute to a
healthy environment.
Question 7–20 Define sheet grid coordinate.
OPTIONAL QUESTIONS
Question CD7–7 Explain the difference between a
cursor and cross hairs.
Refer to the student CD: The CADD Workstation to answer the
following questions:
Question CD7–8 Briefly discuss each of the following
data storage devices:
Question CD7–1 Define microcomputer in general terms.
Question CD7–2 Define ergonomics.
Question CD7–3 Describe the following components of
a computer-aided drafting workstation:
a. Disk
b. Hard drive
c. Optical disk
d. High-capacity disk drive
a. Computer
b. Monitor
PROBLEMS
c. Digitizer
d. Plotter
Question CD7–4 Define the following CADD terms:
a. Hardware
b. Software
c. Program
d. Commands
e. Soft copy
f. Default value
DIRECTIONS: Write a report of approximately 250 words on
one or more of the following topics. Use illustrations to accompany your report or reports.
Problem 7–1 Productivity.
Problem 7–2 Ergonomics.
Problem 7–3 CADD workstation.
Problem 7–4 Customizing your own architectural
symbols.
g. Disk drive
Problem 7–5 Architectural program by a software
developer.
h. Storage
Problem 7–6 CADD layers.
i. Floppy disk
Problem 7–7 Digitizing existing drawings.
j. Menu
Problem 7–8 Scanning existing drawings.
k. Hard copy
Problem 7–9 Virtual building.
l. File
Problem 7–10 Virtual reality.
m. Network
Problem 7–11 Repetitive strain injury.
n. PC
Problem 7–12 Ergonomic workstation.
o. Puck
Problem 7–13 Positive work habits.
p. Mouse
Problem 7–14 Data storage devices.
q. Stylus
Problem 7–15 Computer networks.
Chapter 7: Computer-Aided Design and Drafting in Architecture
Problem 7–16 Mobile computers.
Problem 7–17 Design coordination.
Problem 7–18 Web-based architectural collaboration.
Problem 7–19 The U.S. National CAD Standard.
137
Problem 7–22 U.S. National CAD Standard: Drawing set
organization.
Problem 7–23 U.S. National CAD Standard: Sheet
organization.
Problem 7–20 Plotting a drawing.
Problem 7–24 U.S. National CAD Standard: Drafting
conventions.
Problem 7–21 U.S. National CAD Standard: AIA CAD
Layer naming guidelines.
Problem 7–25 U.S. National CAD Standard: Symbols.
This page intentionally left blank
www.kevinmillerphoto.com
SECTION 2
Residential
Design
This page intentionally left blank
CHAPTER 8
Construction
Specifications
I
N
T
R
O
D
U
C
T
I
O
N
Building plans, including all of the elements that make up a
complete set of residential or commercial drawings, contain
general and specific information about construction. It is often
very difficult to provide all of the required information on a set
of plans. Schedules, as discussed in detail in Chapter 16, provide
specific information about items and applications such as doors,
windows, appliances, fixtures, hardware, finishes, and structural
components. Information that cannot be provided clearly or
completely on the drawing or in schedules is provided in construction specifications. Specifications are an integral part of any
set of plans. Specifications are part of the construction and
contract documents consisting of written technical descriptions
of materials, equipment, construction systems, standards, and
work quality.
Construction specifications often follow the guidelines
of the individual architect or engineering firm where
the architectural design and drawings are created.
Specifications can be as basic as a description of materials created for a construction loan, or can be as indepth as MasterFormat, a detailed specifications format
published by the Construction Specifications Institute
(CSI) and Construction Specifications Canada (CSC).
RESIDENTIAL DESCRIPTION
OF MATERIALS
Most lenders have a format for providing
residential construction specifications. The Federal
Housing Administration (FHA) and the Federal Home
Loan Mortgage Corporation (FHLMC) have a specification format titled Description of Materials. This specifications form is used widely, as is or with revisions, by
most residential construction lenders. The same form is
used by the Farm Home Administration (FmHA) and
by the Veterans Administration (VA).
A completed FHA Description of Materials form for a
typical structure is found on the Student CD and shown
in Figure 8-1. The sample completed form is for the
model home used in the step-by-step instructions found
throughout this textbook. A blank FHA Description of
Materials form is also found on the Student CD. You can
also access this form online by doing an Internet search
using the words FHA Description of Materials. The plans,
construction specifications, and building contract
together become the legal documents for the construction project. These documents should be prepared very
carefully in cooperation with the architect, client, and
contractor. Any variation from these documents should
be approved by all three parties. When brand names are
used, a clause specifying “or equivalent” can be added.
This means that another brand that is equivalent in
value and quality to the one specified can be substituted
with the client or construction supervisor’s approval.
GENERAL CONSTRUCTION
SPECIFICATIONS
Specifications are written documents that describe
in detail the requirements for products, materials,
and workmanship upon which the construction project is based. A specification is an exact statement
describing the characteristics of a particular aspect
of the project. Specifications communicate information
about required products to be used in construction,
as a basis for competitive construction bidding, and
to measure compliance with contracts. Proprietary
product specifications, method specifications, and endresult specifications are types of performance specifications commonly used in the construction industry.
Proprietary product specifications provide specific
product names and models for desired applications.
When this type of specification is used, a named
product can be followed by “or equivalent,” which
allows for equal alternatives and helps promote competition in providing the product. Proprietary product
specifications can limit competition, increase cost,
and decrease flexibility. Method specifications outline
material selection and the construction operation process to be followed in providing construction materials
and practices. Method specifications provide the final
desired structure, such as the concrete thickness and
strength, or the lumber dimensions, spacing, species,
141
142
Architectural Drafting and Design
FIGURE 81 Completed FHA Description of Materials form for the model home used throughout this textbook.
Chapter 8: Construction Specifications
FIGURE 81 Continued
143
144
Architectural Drafting and Design
FIGURE 81 Continued
Chapter 8: Construction Specifications
FIGURE 81 Continued
145
146
Architectural Drafting and Design
and grade. Method specifications allow for more flexibility, but the owner is responsible for the performance.
End-result specifications describe the final characteristics of the products and methods used in construction,
and the contractor can use a desired method for meeting the requirements. End-result specifications often
provide minimum and maximum as a range of acceptable completion. For example, slab gravel under concrete might be specified between 4" and 8" thick with
specific compaction given. End-result specifications
can use statistical methods to estimate overall material
quality based on a limited number of random samples.
End-result specifications place construction quality on
the contractor, by defining the desired final product.
This gives the contractor freedom in achieving that
final product, which can lead to innovation, efficiency,
and lower costs.
SPECIFICATIONS FOR
RESIDENTIAL DESIGN
Minimum construction specifications, as established by local building officials, vary from one location
to the next, and their contents are dependent on specific
local requirements, climate, codes used, and the extent
of coverage. You should verify the requirements for a
construction project in your location, because they can
be different from those given in this discussion. Refer
to Chapter 9 for specific information related to national
building codes. For more information about the general
classifications of construction specifications, see the
Student CD, TYPICAL MINIMUM CONSTRUCTION
SPECIFICATIONS FOR RESIDENTIAL DESIGN.
SPECIFICATIONS FOR COMMERCIAL
CONSTRUCTION
Specifications for commercial construction projects are
often more complex and comprehensive than the documents for residential construction. Commercial project
specifications can provide very detailed instructions
for each phase of construction. Specifications can establish time schedules for the completion of the project.
Also, in certain situations, the specifications include
inspections in conjunction with or in addition to those
required by a local jurisdiction. Construction specifications often follow the guidelines of the individual
architect or engineering firm, although a common
format has been established. Published by CSI and
CSC, the common format is called MasterFormat:
Master List of Numbers and Titles for the Construction Industry. The information used in this textbook
is from MasterFormat and UniFormat and is published by CSI and CSC; it is used with permission
from CSI, 2008. For more information on organizations involved with construction specifications,
please contact:
Construction Specifications Institute (CSI)
99 Canal Center Plaza, Suite 300
Alexandria, VA 22314
800-689-2900; 703-684-0300
Web site: www.csinet.org
Construction Specifications Canada (CSC)
Web site: www.csc-dcc.ca
The MasterFormat: Master List of Numbers and Titles
for the Construction Industry is a master list of numbers
and subject titles for organizing information about
construction work results, requirements, products, and
activities into a standard sequence. Construction projects use many different delivery methods, products,
and installation methods. Successful completion of
projects requires effective communication among the
people involved. Information retrieval is nearly impossible without a standard filing system familiar to each
user. Using MasterFormat numbers and titles facilitates
standard filing and retrieval schemes throughout the
construction industry. MasterFormat numbers and
titles are suitable for use in project manuals, for organizing cost data, for referencing keynotes on drawings,
for filing product information and other technical data,
for identifying drawing objects, and for presenting construction market data. Each MasterFormat number and
title defines a “section,” arranged in “levels” depending on the depth of coverage. The broadest collections
of related construction products and activities are
level-one titles, otherwise known as “divisions.” Each
division in the MasterFormat 2004 Edition: Numbers
and Titles is made up of level-two, level-three, and
occasionally level-four numbers and titles assigned by
MasterFormat, each of which defines a gradually more
detailed area of work results to be specified. Work
results are traditional construction practices that typically result from an application of skills to construction
products or resources.
The MasterFormat 2004 Edition numbers are established using a six-digit system. The following is an
example showing how the list of numbers and titles
is used:
Division 04 Masonry
The first two numbers, 04 in this example, represent the division and are also called level one. The
complete list of divisions is given in the next section
of this textbook.
Chapter 8: Construction Specifications
147
SPECIFICATIONS GROUP
04 05 19.26
Division / Level one—Masonry
Level two—Common Work Results for Masonry
Level three—Masonry Anchorage and Reinforcing
Level four—Masonry Reinforcing Bars
GENERAL REQUIREMENTS SUBGROUP
Division 01 General Requirements
FACILITY CONSTRUCTION SUBGROUP
Division 02 Existing Conditions
FIGURE 82 Construction Specifications Institute (CSI)
MasterFormat titles and numbering system.
Division 03 Concrete
Division 04 Masonry
Division 05 Metals
04 05 Common Work Results for Masonry
The second pair of numbers, 05 in this example, is
referred to as level two. In this case, Common Work
Results for Masonry is a subcategory of Masonry.
04 05 19 Masonry Anchorage and Reinforcing
The third pair of numbers, 19 in this example, is
called level three. In this case, Masonry Anchorage
and Reinforcing is a subcategory of Common Work
Results for Masonry.
04 05 19.26 Masonry Reinforcing Bars
Occasionally, level-four numbers are provided, such
as .26 in this example. When level-four numbers
are used, they follow level-three numbers and are
separated from level-three numbers with a dot. Levelfour numbers are used when the amount of detail
requires an additional level of classification. In this
case, Masonry Reinforcing Bars is a subcategory of
Masonry Anchorage and Reinforcing.
An example of the six-digit numbering system with
levels one through four is shown in Figure 8-2.
Division 06 Wood, Plastics, and Composites
Division 07 Thermal and Moisture Protection
Division 08 Openings
Division 09 Finishes
Division 10 Specialties
Division 11 Equipment
Division 12 Furnishings
Division 13 Special Construction
Division 14 Conveying Equipment
Divisions 15 through 19 Reserved
FACILITY SERVICES SUBGROUP
Division 20 Reserved
Division 21 Fire Suppression
Division 22 Plumbing
Division 23 Heating, Ventilating, and AirConditioning (HVAC)
Division 24 Reserved
Division 25 Integrated Automation
MasterFormat Division Numbers
and Titles
The MasterFormat has two main groups: (1) Procurement and Contracting Requirements, and (2) Specifications. Procurement and Contracting Requirements
are referred to as series zero because they begin with a
00 level-one numbering system prefix. These documents are not specifications. They establish relationships, processes, and responsibilities for projects. The
Specifications group contains the construction specifications subgroups and their related divisions. Some
divisions are identified as reserved for future additions
or specific user applications. The following is an outline of the divisions found in the two groups:
PROCUREMENT AND CONTRACTING REQUIREMENTS GROUP
Division 00 Procurement and Contracting
Requirements
Division 26 Electrical
Division 27 Communications
Division 28 Electronic Safety and Security
Division 29 Reserved
SITE AND INFRASTRUCTURE SUBGROUP
Division 30 Reserved
Division 31 Earthwork
Division 32 Exterior Improvements
Division 33 Utilities
Division 34 Transportation
Division 35 Waterway and Marine Construction
Divisions 36 through 39 Reserved
PROCESS EQUIPMENT SUBGROUP
Division 40 Process Integration
Division 41 Material Processing and Handling
Equipment
148
GOING
GREEN
GreenFormat
The Construction Specifications Institute has established
GreenFormat: The Construction Product Sustainability
Information Reporting Guide. GreenFormat is a new CSI
format allowing manufacturers to accurately report the
sustainability measuring properties of their products,
and providing designers, contractors, and building
operators with basic information to help meet “green”
requirements. When using GreenFormat, construction
product manufacturers complete an online GreenFormat
reporting questionnaire that collects the sustainable
information about their product. Data from the
questionnaires are displayed in a standardized style
designed to ease sustainable design decision making.
Access to the GreenFormat report and the resulting data
is provided through http://www.greenformat.com.
Those using the Web site can print reports on specific
products based on their questions within the database.
Sustainable information reported in GreenFormat is
grouped into categories, each containing individual topics
and questions about product sustainability. The categories
are organized with topics more likely to be important
to design decisions first. This flexible structure can adapt
to anticipated changes in the industry. As sustainability
issues evolve, new topics and questions are added in the
appropriate category, and existing topics and questions
that become obsolete or change are dropped if necessary.
The structure can be applied to all construction products
and product categories. Refer to www.greenformat.com
to see the categories and their contents and to view
additional information about GreenFormat.
Division 42 Process Heating, Cooling, and Drying
Equipment
Division 43 Process Gas and Liquid Handling,
Purification, and Storage Equipment
Division 44 Pollution Control Equipment
Division 45 Industry-Specific Manufacturing
Equipment
Divisions 46 and 47 Reserved
Division 48 Electrical Power Generation
Division 49 Reserved
commissioning, operation, and decommissioning.
The purpose of UniFormat is to achieve consistency
in economic evaluation of projects; enhance reporting of design program information; and promote
consistency in filing information for facility management, drawing details, and construction market data.
UniFormat classifies information into nine level-one
categories, which can be used to arrange brief project
descriptions and preliminary cost information. The
first level-one category is Project Description, which
includes information about the project, through cost
estimating and funding. The last eight level-one categories are referred to as Construction Systems and
Assemblies, which include construction applications
and practices, such as foundation, roofing, exteriors,
electrical, and plumbing. Each of the Construction
Systems and Assembly categories is identified with a
letter and title as follows:
The UniFormat Uniform
Classification System
UniFormat is a uniform classification system for organizing preliminary construction information into a
standard order or sequence on the basis of functional
elements. Functional elements, also referred to as
systems or assemblies, are common major components in buildings that perform a known function
regardless of the design specification, construction
method, or materials used. The use of UniFormat can
provide consistent comparable data across an entire
building life cycle. Building life cycle refers to the
observation and examination of a building over the
course of its entire life. The life cycle of a building
considers everything about the building from design,
A—Substructure
B—Shell
C—Interiors
D—Services
E—Equipment and Finishings
F—Special Construction and Demolition
G—Building Site Work
Z—General
Chapter 8: Construction Specifications
UniFormat has a numbering system that divides
each level-one category into level-two, level-three,
level-four, and level-five titles with set alphanumeric
labels. The following is an example showing the first
three levels of the UniFormat alphanumeric system for
a specific category:
Level 1: D Services
Level 2: D20 Plumbing
Level 3: D2010 Plumbing Fixtures
CONSTRUCTION DOCUMENTS
Documents is a general term that refers to all drawings and written information related to a project.
Construction documents are drawings and written
specifications prepared and assembled by architects
and engineers for communicating the design of the
project and administering the construction contract.
The two major groups of construction documents
are bidding requirements and contract documents.
Bidding requirements are used to attract bidders
and explain the procedures to be used for submitting
bids. Bidding requirements are the construction documents issued to bidders for the purpose of providing
construction bids. Contract documents are the legal
requirements that become part of the construction
contract. The construction drawings and specifications
are found within the contract documents.
Construction Drawings
As you learn concepts and develop skills covered
throughout this textbook, you will be creating construction drawings. Drawings show lines and text
for the purpose of providing information about the
project. These drawings are a principal part of the
set of construction documents. The individual drawings needed depend on the specific requirements of
the construction project. The drawings for a small
residential addition might fit on one or two pages,
while the drawings for a commercial building might
be on a hundred or more pages. Drawings vary in how
much information they show, depending on the use,
the project phase, and the desired representation. In
addition to plan views, elevations, sections and details,
drawings can have schedules that have a detailed list
of components, items, or parts to be furnished in the
project. You will create all of these drawings and features as you progress through this textbook.
149
Coordinating Drawings
and Specifications
A complete set of construction documents contains
drawings and specifications. These combined drawings and specifications are often referred to as plans.
One person or a unified team of people should coordinate drawings and specifications. The elements used
in the drawings and specifications, such as symbols,
abbreviations, and terminology, should be standardized to prevent confusion. After the construction
documents are prepared in a professional manner, the
construction coordination must be conducted with
effective communication.
The drawings should locate and identify materials and should include the assembly of components,
dimensions, details, and diagrams. The drawings have
notes, but notes should be used only to identify, not to
describe, a material or part. Overly detailed notes can
obscure the drawing. Detailed written information
should be placed in the specifications. Symbols used
in the set of drawings should be represented as an
approved standard and should be shown and labeled
in a legend for reference purposes. Drawings do not
need to be cross-referenced to the specifications.
Drawings and specifications are combined to become
the complete set of construction documents, which
means that you do not have to provide notes that
refer to the specifications when identifying an item
on the drawings. The specifications are used to define
the specific quality and type of material, equipment,
and installation. The drawings provide quantity,
capacity, location, and general written information in
the form of notes, whereas the specifications clearly
define items such as minimum requirements, physical properties, chemical composition, and installation
procedures. Schedules are used on drawings to help
simplify communication by providing certain items
in a table format. The schedules can be placed on the
drawings or in the specifications. The information
found in schedules or on the drawings should not
repeat the information found in the specifications.
The drawings, schedules, and specifications must be
carefully coordinated so the information is consistent. The MasterFormat divisions and sublevels can
be used as a checklist to ensure that every required
specification is included. MasterFormat is an effective
system for indexing specifications for large projects,
and can be used for light commercial or residential
construction.
150
Architectural Drafting and Design
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource
to help you find information related to construction
specification procedures and keep current with trends
in the industry.
These Web site links are also provided on the Student
CD where you can select a link and go automatically to
the specified Web site.
Address
www.csc-dcc.ca
www.csinet.org
www.greenformat.com
www.nahb.org
www.hud.gov
GreenFormat report and the
resulting data
National Association of
Home Builders
U.S. Department of Housing
and Urban Development
Company, Product,
or Service
Construction Specifications
Canada
Construction Specifications
Institute
See CD
for more
information
Construction Specifications Test
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 8 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 8–1 Give a general definition of construction
specifications.
Question 8–2 Identify the basic differences between
residential and commercial specifications.
Question 8–3 List four factors that influence the specific
requirements of minimum residential construction
specifications established by local building officials.
Question 8–4 Refer to the Student CD: Supplemental
Reference, TYPICAL MINIMUM CONSTRUCTION
SPECIFICATIONS FOR RESIDENTIAL DESIGN. Using
general terms, list the typical minimum construction
requirements for the following categories:
f. Roof
g. Chimney and fireplace
h. Thermal insulation and heating
i. Fire warning system
A partial example would be as follows:
4. d. Framing
1. lumber grades
2. beams bearing area
Question 8–5 Briefly describe the format established
by the Construction Specifications Institute (CSI) for
construction specifications.
Question 8–6 Define work results.
Question 8–7 Define functional elements.
Question 8–8 Define systems or assemblies.
Question 8–9 Define building life cycle.
Question 8–10 Define construction documents.
Question 8–11 Define bidding requirements.
Question 8–12 Define contract documents.
a. Room dimensions
b. Light and ventilation
c. Foundation
d. Framing
e. Stairways
PROBLEMS
Problem 8–1 Obtain a blank copy of the FHA
Description of Materials form from your instructor,
from the Student CD, or by doing an Internet search
Chapter 8: Construction Specifications
using the words FHA Description of Materials. Make
a copy or print of the Description of Materials form
and keep it in a notebook or folder for reference.
Alternately, if you access the Description of Materials
form from the Internet, you can save a copy in a
file with the same name on your computer. As you
progress through this textbook, problems are assigned
that allow you to complete a set of residential working
drawings. Access and complete the Description of
Materials form as you complete each drawing in the set
of architectural plans for the residence you select or are
assigned as a continuing problem. If you create more
than one set of plans, fill out a separate Description of
Materials form for each set of working drawings.
Problem 8–2 Use a word processor to write an
approximately 150-word report covering the difference
151
between proprietary product specifications, method
specifications, and end-result specifications.
Problem 8–3 Use a word processor to write an
approximately 500-word report covering the
Construction Specifications Institute and Construction
Specifications Canada MasterFormat: Master List
of Numbers and Titles for the Construction Industry.
Include detailed information about the purpose and
function of this specifications format. Explain and
show an example of the numbering system. List the
MasterFormat division numbers and titles.
Problem 8–4 Use a word processor to write an
approximately 250-word report covering construction
documents, construction drawings, and coordinating
drawings and specifications.
CHAPTER 9
Guidelines and Required
Codes That Affect
Building Design
I
N
T
R
O
D
U
C
T
I
O
N
Architects and designers must deal with a multitude of
guidelines and required codes that will affect home design.
Guidelines have traditionally come from home-owner
associations, but many designers and builders are now
attempting to follow green building guidelines established
by the Leadership in Energy and Environmental Design
(LEED) and the National Green Building Standard (NGBS)
published by the National Association of Home Builders
(NAHB) and the International Code Council (ICC). For most
municipalities, these guidelines are just that, but some areas
have adopted these guidelines into law. Building codes are
required laws that are intended to protect the public by
establishing minimum standards of safety. Although landowners often assume that they can build whatever they
want because they own the property, building codes are
intended to protect everyone, including the neighbors,
visitors and potential future owners. Consider the stories
you have seen in the national news media about structures
that have been damaged by high winds, raging floodwaters,
hurricanes, tornadoes, mudslides, earthquakes, and fire.
Although they do not make the national news, hundreds
of other structures become uninhabitable because of
inadequate foundation design, failed members from poor
design, mold, rot, or termite infestation. Building codes are
designed to protect consumers by providing minimum
guidelines for construction and inspection of a structure
to prevent fire, structural collapse, and general deterioration. Many other aspects of building construction, such as
electrical wiring, heating equipment, and sanitary facilities,
represent a potential hazard to occupants if not designed
and constructed or installed properly. Building codes are
enforced as a safeguard against these risks.
the home in Figure 9-1 are designed to meet certain
objectives such as protecting the health of the occupants; using energy, water, and other resources more
efficiently; and reducing the overall impact to the
environment. The biggest leaders in residential green
building are LEED and the NGBS-ICC 700.
NOTE: Although both groups have produced “guidelines,”
many municipalities are starting to move beyond the
recommendation stage and are incorporating portions
of these guidelines into their design and building requirements. It is expected that with the 2012 edition of the ICC
codes, the NGBS-ICC 700 will move from guidelines to law.
Verify with the municipality that will govern each specific
building project to determine if specific aspects of a green
guideline are required. The ICC is also planning to develop
a green building code for buildings that are not covered
by the NGBS-ICC 700. This code will most likely be the
International Green Construction Code (IGCC).
GREEN BUILDING GUIDELINES
Green building is the incorporation of environmental
considerations and resources into every step of the
construction process. A green or environmentally
friendly building is a structure that is designed, built,
operated, renovated, and recycled in an ecological and
resource-efficient manner. Green buildings similar to
152
FIGURE 91 An environmentally friendly home is designed to
blend with its environment; protect the health of the occupants;
use energy, water, and other resources efficiently; and reduce
the overall impact to the environment. This sunroom provides a
comfortable living area while serving as a passive solar collector.
Courtesy BOWA Builders, Inc. Greg Hadley, photographer.
Chapter 9: Guidelines and Required Codes That Affect Building Design
LEED Green Building Guidelines
The LEED Green Building Rating System is a leader
in environmentally friendly design and construction.
Incorporating the MasterFormat numbering system
introduced in Chapter 1 and discussed in detail in
Chapter 8, the guidelines are designed to help improve
the quality of buildings and to minimize their impact
on the environment. The rating system, developed by
the U.S. Green Building Council (USGBC), is intended
to blend the structure with the environment, reduce
operating costs, and aid in marketing the structure
for resale. LEED certification requires that the project meet the fundamentals, and score a minimum
number of points in a LEED rating system. LEED
certification acknowledges four levels of certification, including:
153
7. Landscape and exterior design to reduce heat
islands—see divisions 6, 7, 10, and 32.
8. Light pollution reduction—see divisions 1 and 26.
Water Efficiency
Three credits are available related to the use, and reduction of the use of water in the structure and at the building site. Chapter 20 of this text will explore the use of
water in a residence. LEED credits for water efficiency
include:
●
Water-efficient landscaping—see divisions 7, 22, 32,
33, and 44.
● Innovative wastewater technologies—see divisions
22, 32, 33, and 34.
● Water use reduction—see divisions 11, 22, and 23.
1. Certified: 26–32 points.
Indoor Environmental Quality
2. Silver: 33–38 points.
Eight credits are available related to the interior air
quality of the structure. Chapter 12 and Chapter 21 will
address these areas of home design. LEED credits for
indoor environmental quality include:
3. Gold: 39–51 points.
4. Platinum: 52 points or more.
Key areas of the construction process and their corresponding Construction Specifications Institute (CSI)
MasterFormat 2004 division number (see Chapter 8
for a listing of CSI divisions) are covered by the LEED
rating system. These areas include sustainable sites,
water efficiency, indoor environmental quality, energy
and atmosphere, material and resources, and innovation
and the design process.
Sustainable Sites
This area of the credits is applied to efficient design
and construction as it relates to the construction site.
Although the standard is intended for residential
design, many credits in this area are best applied to
multifamily design. Section 3 of this text will further
explore environmental considerations of site design.
Eight credits are available related to sustainable sites,
including:
1. Site selection—see CSI division 32.
2. Urban redevelopment—no CSI divisions are cur-
rently available for this area.
3. Brownfield redevelopment—no CSI divisions are
currently available for this area.
4. Alternative transportation—see division 12.
5. Reduced site disturbance—see divisions 31 and 32.
6. Stormwater management—see divisions 7, 10, 22,
31, 32, and 33.
1. Carbon dioxide monitoring—see divisions 1, 23,
and 28.
2. Increase ventilation effectiveness—see divisions 9,
11, 12, and 23.
3. Construction interior air quality management plan—
see divisions 1, 2, 3, 6, 7, 8, 12, 23, and 28.
4. Low-emitting materials—see divisions 1, 2, 3, 6, 7, 8,
9, 12, and 23.
5. Indoor chemical and pollutant source control—see
divisions 4, 7, 10, 12, 14, 22, and 23.
6. Controllability of systems—see divisions 8, 23,
and 26.
7. Thermal comforts—see divisions 8, 23, and 28.
8. Daylight and views—see divisions 7, 8, 10, 12,
and 26.
Energy and Atmosphere
Six credits are available related to the use of energy to
control the atmosphere within a residence. Chapter 12
and Chapter 21 will address this area of home design.
LEED credits for energy and atmosphere include:
1. Optimize energy performance—see divisions 1, 3, 4,
5, 6, 7, 8, 9, 10, 11, 12, 13, 22, 23, 26, 28, 33, 35, 42,
and 44.
2. Renewable energy—see divisions 1, 7, 8, 22, 23,
and 26.
154
3. Additional commissioning—see divisions 1, 23,
and 26.
4. Elimination of hydro chlorofluorocarbons (HCFCs)
and halons—see divisions 13, 22, 23, and 26.
5. Measurement and verification—see divisions 1, 23,
26, and 27.
6. Green power—no CSI divisions are currently available for this area.
Material and Resources
Seven credits are available that are related to the materials and products used to build and sustain a structure.
Sections 6, 7, 8, and 9 will address these areas of home
design. LEED credits include:
1. Building reuse—see divisions 3 and 9.
2. Construction waste management—see divisions 2, 9,
and 26.
3. Resource reuse—see divisions 1, 4, 6, 7, 8, 9, 12,
and 32.
4. Recycle content—see divisions 1, 3, 4, 5, 6, 7, 8, 9,
10, 11, 12, 23, 32, 33, 34, and 35.
5. Local and regional materials—no CSI divisions are
currently specified for this area.
6. Rapidly renewable materials—see divisions 1, 3, 4, 6,
7, 8, 9, 10, 12, 14, 23, 31, and 32.
7. Certified wood—see divisions 1, 3, 6, 7, 8, 9, 10,
and 12.
Innovation and the Design Process
Two credits are available that are related to the design
phase of a residence. Section 1 addresses these areas of
home design. LEED credits for innovation and design
include:
Architectural Drafting and Design
lot design, preparation, and development; resource
efficiency; energy efficiency; water efficiency; indoor
environmental quality; operation, maintenance, and
building owner education.
Site Design and Development
This area of the guidelines describes considerations for
resource efficient site design and development practices
that can improve the energy efficiency of a structure.
Section 3 of this textbook will further explore environmental considerations of site design.
Lot Design, Preparation, and Development
This area of the standards describes considerations for
lot selection, lot design, lot construction, and innovative
practices that can be incorporated in the design of the
driveway and parking areas, and heat island mitigation.
Section 3 of this textbook will further explore environmental considerations of lot design.
Resource Efficiency
Creating resource efficiency includes the consideration
of materials to build and furnish the home to maximize
the function and optimize the use of natural resources.
Areas covered include: quality of construction materials
and waste, enhanced durability and reduced maintenance, reduced and salvaged materials, recycled-content
building materials, recycled construction waste, renewable materials, resource-efficient materials, indigenous
materials, life-cycle analysis, and innovative practices.
Sections 6, 7, 8, and 9 of this text will further address the
use of energy-efficient materials like those in Figure 9-2
for residential projects.
1. Innovation in design—no CSI divisions are currently
specified for this area.
2. About LEED—no CSI divisions are currently specified for this area.
National Green Building
Standards-ICC 700
In collaboration with the NAHB, the ICC has developed the National Green Building Standard ICC 700.
The guidelines allow the designer to use a wholehouse systems approach throughout the design
process to increase the home’s performance and efficiency. Seven key sections are included in the NGBSICC 700 guidelines: Site design and development;
FIGURE 92 The use of energy-efficient materials such as insulated concrete forms, structurally insulated panels (SIPs), and
engineered products can increase the energy efficiency of a
home. Courtesy PolySteel Insulating Concrete Forms.
Chapter 9: Guidelines and Required Codes That Affect Building Design
Energy Efficiency
This area of the standard describes considerations for
helping the residents of the home reduce their dependence on fossil-fuel energy sources. Attention is not only
given to the operation of the home, but credits are also
earned throughout the construction of the home, and
for the materials that are used to construct the home.
Major elements of the standard include minimum energy
efficiency requirements, performance path, prescriptive
path, additional practices, and innovative practices.
Sections 5, 6, 7, 8, and 9 of this text book will further
address the use of energy-efficient materials.
Water Efficiency
This portion of the standard is aimed at reducing water
consumption both inside and outside the home as well
as the incorporation of innovative practices. The plumbing products and appliances that are specified can help
reduce water use inside the home. The selection of
native and drought-resistant landscaping, the collection
of rainwater for irrigation, as well as the reuse of gray
water from the house can reduce or eliminate water
use outside the home. Chapter 20 of this textbook will
explore the use of water in a residence.
Indoor Environmental Quality
According to NAHB research, the indoor air quality of
a home is often the number one green consideration
of home buyers. Inside air quality is affected by the
mechanical equipment used to heat and cool the home
and by the materials that are used to construct and
furnish the home. The NGBS-ICC 700 awards points
for the categories of pollutant source control, pollutant control, moisture management, and innovative
practices. Chapter 12 and Chapter 21 of this text will
address these areas of home design.
Operation, Maintenance, and Building
Owner Education
Designing or building an energy-efficient home is futile
if you can not convince the home owner to invest in the
home, or to maintain key features of the home once it
is constructed. This credit is earned by providing the
building owners with the operation and maintenance
manuals as well as the construction, operation, and
maintenance manuals to properly operate their home.
Levels of Certification
Similar to the LEED system that allows credits to
be accumulated based on the areas of the guidelines that are used, the NGBS-ICC 700 provides for
four levels of performance to be achieved, based on
155
how the green building categories are incorporated
into the plan. The basic level of achievement is the
Bronze level. A Bronze designation indicates that the
home features items that demonstrate that the design
pays attention to a project’s environmental impact.
The Silver, Gold, and Emerald levels of certification
include additional criteria that place increasingly
greater emphasis on green practices.
NATIONAL BUILDING CODES
The regulation of buildings can be traced through
recorded history for more than 4000 years. In early
America, George Washington and Thomas Jefferson
encouraged building regulations as minimum standards
for health and safety. Building codes are now used
throughout most of the United States to regulate issues
related to fire, structural ability, health, security, and
energy conservation. Architects, engineers, interior
designers, and contractors also rely on building codes
to help regulate the use of new materials and technology. Model code organizations oversee accredited laboratories and testing facilities in order to develop safe,
cost-effective, timely construction methods. In addition
to the testing facilities of each major code, several major
material suppliers have their own testing facilities. A list
of Web sites for several major testing labs, quality assurance, and inspection agencies is available at the end of
the chapter in the Additional Resources section.
Although most areas of the country understand the
benefits of regulating construction, each city, county,
or state has the authority to adopt building codes in
accordance with their state laws. While some areas do
not have adopted codes, most areas do. This system
of codes is based on the government system of the
United States where regulation at the state and local
level is considered very important. Accordingly, many
jurisdictions that adopt building codes, adopt them
with local amendments. As a result, even though
the majority of the United States uses the same base
model building code, the users should be aware of
local variations because of the local amendments to
the base code.
National Code Options
Most states have adopted the building codes published
by the International Code Council (ICC), but a small
number of jurisdictions might still be using one of the
legacy codes of the ICC. The current editions of the ICC
codes are the 2009 editions of which the IRC could possibly incorporate 30% more energy efficiency in its 2012
156
edition which is slated for publication in late 2011. The
ICC legacy codes consist of:
●
Building Officials and Code Administrators
International, Inc. The 1999 BOCA National Building
Code was the last edition published.
● Southern Building Code Congress International, Inc.
The 1999 SBC (Standard Building Code) was the last
edition published.
● International Conference of Building Officials. The
1997 UBC (Uniform Building Code) was the last edition published.
It is important to remember that each municipality
and state has the right to adopt all, or a portion, of the
indicated code. Although all of the legacy code organizations of BOCA, ICBO and SBCCI have merged to
form the ICC and one code, the IRC and other family of
its codes, the legacy codes, NBC, SBC and UBC, are still
available and could be used by some municipalities.
International Code Family
In 1972, in order to serve designers better, BOCA,
SBCCI, and ICBO joined forces to form the Council of
American Building Officials (CABO) to create a national
residential code. While some jurisdictions adopted
this code, most decided to continue their prior codes
of NBC, SBC and UBC and not adopt the CABO One
and Two Family Dwelling Code. In 1994, in another
attempt to create a national code, the International
Code Council (ICC) was formed. The goal of the ICC
is to develop a single set of comprehensive, coordinated
national codes that would eliminate disparities among
the previous three major legacy codes. The ICC has
published the 2009 editions of the International Building
Code (IBC) and the International Residential Code (IRC).
These codes are referred to as the model codes. The IBC
in general covers all buildings except detached single
family, two-family and townhouses three stories or
less in height. The IRC covers detached single family,
two-family and townhouses three stories or less in
height to ensure quality residential construction. Each
of these codes has combined certain features, best or
most consistent requirements, of the BOCA, NBC, SBC,
and the UBC into one base code. Most municipalities
are now using these codes, or their amended version of
this code, to govern residential construction. The ICC
also published the International Energy Conservation
Code with portions that apply to both residential and
commercial construction. Verify the building code that
governs your area with your local building department
prior to starting construction drawings.
Architectural Drafting and Design
NOTE: Information in this text is based on the 2009
International Residential Code (IRC) for One- and TwoFamily Dwellings published by the ICC. Listings of metric
sizes in this chapter are shown as soft metric conversions
in order to be consistent with the IRC listings. Visit the
International Code Council Web site to verify the release of
the codes that govern your area. You will need to verify with
your local building department to determine if the new edition has been adopted.
In addition to these national codes, the Department
of Housing and Urban Development (HUD), the Federal
Housing Authority (FHA), and the Americans with
Disabilities Act (ADA) each publish guidelines for
minimum property standards for accessibility for the
disabled some provisions of which might apply to certain residential construction.
Choosing the Right Code
The architect and engineer are responsible for checking with the local jurisdictions and determining which
code will be used during the design process and for
ensuring that the structure complies with all required
codes. Although the drafter is not expected to make
decisions regarding the codes as they affect the design,
drafters are expected to know the content of the codes
and how they affect construction.
Each of the major codes is divided into similar sections that specify regulations covering these areas:
●
Fire and Life Safety
Structural
● Mechanical
● Electrical
● Plumbing
●
The Fire and Life Safety and Structural codes have
the largest effect on the design and construction of a
residence. The effect of the codes on residential construction will be discussed throughout this textbook.
Chapter 42 examines the effects of the IBC on commercial construction.
BASIC DESIGN CRITERIA
FOR BUILDING PLANNING
Building codes influence both the design and construction methods. The influence of codes on construction
methods will be discussed later in this chapter and
throughout Sections 4, 6, 7, 8, 9, and 10 of this textbook.
Drafters and designers need to be familiar with several
areas in order to meet minimum design standards,
Chapter 9: Guidelines and Required Codes That Affect Building Design
including basic design criteria. Areas of the code such
as climatic and geographical design criteria will affect
the materials used to resist forces such as wind, snow,
and earthquakes. These forces and how they affect a
residence will be discussed in Chapter 29. Keep in mind
that the following discussion is only an introduction
to building codes. As a professional drafter or designer
you will need to become familiar with, and constantly
use, the building code that governs your area. It’s also
important as you start to explore building codes that
you understand the common markings that are used by
the ICC to identify items in the text including:
●
Black text represents information that has remained
the same from the previous edition of the code.
● Black text with a bold vertical line in the margin
beside the text represents information that is new or
has been revised from the last edition to the current
edition.
● A bold black arrow placed in the margin between
lines of text, or between paragraphs, represents
where information has been removed from the current code.
Another key element to remember as you start to
explore building codes is that this textbook is based on
the International Residential Code. Many municipalities
will take a base code such as the 2009 IRC, amend it
to meet specific local issues, and then publish the state
version of the code in the following year. Although the
ICC is making efforts to include more options in the
base codes, read the title of your code carefully to verify
you’re working with the correct code.
Habitable and Nonhabitable Space
The space within a home or dwelling unit is subdivided into habitable and nonhabitable space. A room
is considered habitable space when it is used for sleeping, living, cooking, or dining purposes. Nonhabitable
spaces include closets, pantries, bath or toilet rooms,
hallways, utility rooms, storage spaces, garages, darkrooms, and other similar spaces.
Location on the Property
For building code purposes, the exterior walls of
residential building cannot be located within 5' (1524
mm) of the property lines unless special provisions
are met. Keep in mind that zoning regulations may
further restrict the location of the structure to the
property lines. Typically, an exterior wall that is built
within 5' (1524 mm) of the property line must be
157
made from materials that will resist a fire for 1-hour
wall tested in accordance with American Society for
Testing and Materials (ASTM) E119 or UL 263. This
is known as a 1-hour fire rating. Although only 1/2"
(12.7 mm) gypsum board is required on each side
of the wall in certain wall assemblies, using 5/8" (16
mm) type X gypsum board on each side of the wall
is a common method of achieving a 1-hour wall.
Many municipalities require any walls built into the
minimum side yard to be of 1-hour construction.
Openings such as doors or windows are not allowed
in a wall with a fire separation distance less than 36"
(914 mm). Projections such as a roof or chimney
cannot project more than 24" (610 mm) from the
line used to determine the fire separation distance.
The one exception to this rule is that detached
garages located within 24" (610 mm) of the property
line may have a 4" (102 mm) eave projection.
Egress and Accessibility Requirements
for a Residence
The major subjects to be considered for egress are the
path of egress, egress doors, stairs and emergency escape.
Accessibility for the disabled is not required for buildings constructed under the IRC unless there are four or
more dwelling units in a single structure, in which case
chapter 11 of the International Building Code (IBC) for
R-3 Occupancies must be complied with.
Means of Egress
Residential projects are required to provide a continuous and unobstructed path of vertical and horizontal
egress travel from all portions of the dwelling to the
exterior of the dwelling at the required egress door
without requiring travel through a garage.
Egress Doors. Each dwelling unit, as a residence is
referred to in the codes, must have a minimum of one
door that is at least 32" (813 mm) wide measured
between the face of the door when open 90° (1.57 rad)
and the stop. The minimum clear height of the door
opening must be 78" (1981 mm) from the top of the
threshold to the bottom of the stop. The designer can
determine all other door sizes based on personal preferences or the client’s needs.
NOTE: The IRC may only require the main entry door to be
32" (813 mm) wide, but common practice is to provide a 36"
(900 mm) or larger door to provide an inviting entrance.
Remember building codes dictate minimum sizes, not desirable or practical sizes. Chapter 16 provides guidelines for
determining door sizes throughout a residence.
158
Architectural Drafting and Design
A floor or landing must be provided on each side
of an exterior door. The IRC requires the landing to
be a maximum distance of 1 1/2" (38 mm) from the
top of door threshold for required egress doors. The
landing for an exterior door can be within 7 3/4" (196
mm) from the top of the door threshold provided that
the door does not swing over the landing. The minimum landing width must be equal to or greater than
the width of the door at the landing, and the landing
length must be a minimum of 36" (914 mm) measured
in the direction of travel. The landing is required on
each side of the required egress door. Interior landings
are to be level. Exterior landings may have a maximum
slope of 1/4" / 12" (2% slope). This often becomes a
design problem when trying to place a door near a
stairway. Figure 9-3 shows some common door and
landing problems and their solutions.
DOOR MAY NOT
SWING OVER
STAIR
DN
DN
DN
DN
Emergency Egress Openings. The term egress is used
in the IRC to specify areas of access or exits. It is used
in reference to doors, windows, and hallways. Windows
are a major consideration in designing exits. Emergency
egress is required in basements, habitable attics, and
every sleeping room. For basements that contain more
than one sleeping room, emergency egress and rescue
openings are required to be in each sleeping room.
Escape may be made through a door or window that
opens directly into a public street, alley, yard, or exit
court. The emergency escape must be operable from
the inside without the use of any keys or tools. The sill
of all emergency escape bedroom windows must be
within 44" (1118 mm) of the floor. Windows used for
emergency egress must have a minimum net clear area
of 5.7 sq ft (0.530 m2). Grade floor opening size can be
reduced to 5.0 sq ft (0.465 m2). The net clear opening
area must have a minimum width of 20" (508 mm)
and a minimum height of 24" (610 mm). All net clear
openings must be obtainable during normal operation
of the window. This opening gives occupants in each
sleeping area a method of escape in case of a fire (see
Figure 9-4).
Emergency escape windows with a finished sill height
below the surrounding ground elevation must have
a window well that allows the window to be fully
opened. The window well is required to have a clear
opening of 9 sq ft (0.9 m2) with a minimum horizontal projection and width of 36" (914 mm) when the
window is fully open. If the window well has a depth
of more than 44" (1118 mm), the well must have an
approved permanently fixed ladder or stair that can be
accessed when the window is fully opened. The ladder
or stair cannot encroach more than 6" (152 mm) into
the required well dimensions and must have rungs
that have a minimum inside width of 12" (305 mm).
THIS LANDING MUST
BE AS LONG AS
THE STAIR IS WIDE
STEPS AT A DOORWAY
MUST BE WITHIN 7 3/4"
OF FLOOR
FIGURE 93 Placement of doors near stairs. Landings by doors
in group R-3 occupancies must be within 1 1/2" (38 mm) of the
door threshold. When the door does not swing over the landing, the landing can be a maximum of 7 3/4" (197 mm) below
the threshold.
The rungs must be a minimum of 3" (76 mm) from
the wall and must be spaced at a maximum distance of
18" (457 mm) on center (O.C.) vertically for the full
height of the window well.
Emergency escape windows are allowed to be
installed under decks provided the emergency escape
window can be fully opened and provides a path not
less than 36" (914 mm) in height to a yard or court.
Halls
Hallways must be a minimum of 36" (914 mm) wide.
This is very rarely a design consideration because hallways are often laid out to be 42" (1067 mm) wide or
Chapter 9: Guidelines and Required Codes That Affect Building Design
159
20
"
O CLE MIN
PE A
.
R
NI
NG
RUN 10" (254 mm)
RISE 7 3/4" (196 mm)
RUN 11" (279 mm)
RISE 7 3/4" (196 mm)
RUN 10 1/2" (265 mm)
RISE 7 1/2" (191 mm)
24" (610 mm)
CLEAR
OPENING
SILL HEIGHT
44" (1118 mm) MAX.
6'-8" (2030 mm) TYPICAL
AREA OF ESCAPE MUST
EQUAL 5.7 SQ FT (0.53 mm3)
CLEAR OPENING MIN.
20" MIN.
(508 mm)
CLEAR MIN.
WHEN OPEN.
FINISHED FLOOR
FIGURE 94 Minimum emergency escape window opening
sizes. A means of escape is required for all sleeping units including those located in a basement or habitable attic.
wider at the main and service entries to create an open
feeling and to enhance accessibility from room to room.
Stairs
Stairs often can dictate the layout of an entire structure. Because of their importance in the design process, stairs must be considered early in the design
stage. For a complete description of stair construction
see Chapter 39. Minimum code requirements for stairs
can be seen in Figure 9-5. Following the minimum
standards would result in stairs that are extremely
steep, very narrow, and have very little room for foot
INTERNATIONAL RESIDENTIAL CODE
MINIMUM STAIR GUIDELINES
Width (minimum)
*36"
*914 mm
Rise (maximum)
7 3/4"
196 mm
Tread (minimum)
10"
254 mm
*Minimum clear width above the permitted handrail and below the
required headroom height. Below the handrail, 31.5" (787 mm) minimum width with handrail on one side, 27" (698 mm) minimum width
with handrail on each side.
FIGURE 95 Basic design values for stairs.
FIGURE 96 Stair layouts comparing minimum run and maximum rise based on common practice.
placement. Good design practice would provide stairs
with a width of 36" to 42" (914 to 1067 mm) for ease
of movement. A common tread depth is 10" to 10 1/2"
(254 to 267 mm) with a rise of about 7 1/2" (191 mm).
Figure 9-6 shows the difference between the minimum
stair layout and some common alternatives. Within
any flight of stairs, the largest step run cannot exceed
the smallest step by 3/8" (9.5 mm). The difference
between the largest and smallest rise cannot exceed
3/8" (9.5 mm). Headroom over stairs must also be
considered as the residence is being designed. Stairs
are required to have 6'–8" (2032 mm) minimum headroom. Headroom of 6'–6" (1981 mm) is allowed for
spiral stairs. This headroom can have a great effect on
wall placement on the upper floor over the stairwell.
Figure 9–7 shows some alternatives in wall placement
around stairs.
Winding stairs may be used if a minimum width of
10" (254 mm) is provided at a point not more than
12" (305 mm) from the side of the treads. The narrowest portion of a winding stairway may not be less
than 6" (152 mm) wide at any point.
When a spiral stair is the only stair serving an upper
floor area, it can be difficult to move furniture from one
floor to another. Spiral stair treads must provide a clear
walking width of 26" (660 mm) measured from the
outer edge of the support column to the inner edge of
the handrail. A tread depth of 7 1/2" (190 mm) must be
provided within 12" (305 mm) of the narrowest part of
the tread. The rise for a spiral stair must be sufficient to
provide 6'−6" (1981 mm) headroom, but no riser may
exceed 9 1/2" (241 mm), and all risers must be equal.
Circular stairways must have a minimum tread run of
11" (279 mm) measured at a point not more than 12"
(305 mm) from the narrow edge. At no point can the
run be less than 6" (152 mm).
160
Architectural Drafting and Design
LINE OF STAIRS BELOW
FLOOR MAY NOT EXTEND
INTO THE AREA REQUIRED
FOR MINIMUM HEADROOM
6'-8" MIN
(2032 mm)
DN 14 R
6'-8" MIN
(2032 mm)
DN 14 R
FIGURE 97 Wall and floor placement over stairs.
Handrails and Guardrails. All stairways with four or
more risers are required to have at least one smooth
handrail that extends the entire length of the stair. The
rail must be placed on the open side of the stairs and
must be 34" to 38" (864 to 965 mm) above the front
edge of the stair. The height is allowed to exceed the
maximum height as the handrail transitions into the
guardrail. The following types of handrails are allowed
by the IRC:
Type I–Circular. Handrails with a circular cross
section must have a minimum outside diameter of
1 1/4" (32 mm) and not exceeding 2" (51 mm).
Type I—Noncircular. The rail must have a minimum
perimeter dimension of 4" (102 mm) and not exceeding 6 1/4" (160 mm) with a maximum cross section
of 2 1/4" (57 mm).
Type II. Rails with a perimeter greater than 6 1/4"
(160 mm) must have a graspable finger recess area
on both sides of the profile.
Handrails are required to be 1 1/2" (38 mm) from the
wall but may not extend into the required stair width by
more than 4 1/2" (114 mm).
A guardrail must be provided at changes in floor or
ground elevation that exceed 30" (762 mm). Guardrails
are required to be 36" (914 mm) high except on the
open side of the stairs the railing can be reduced to
34" (864 mm) when measured vertically from a line
extending from the leading edges of the treads. Railings
must be constructed so that a 4" (102 mm) diameter
sphere cannot pass through any opening in the rail. The
triangular opening formed by the bottom of the rail and
the stairs must be constructed so that a 6" (152 mm)
sphere cannot pass through the opening. Horizontal
rails or other ornamental designs that form a ladder
effect cannot be used.
Room Dimensions
Room dimension requirements affect the size and ceiling height of rooms. Every dwelling unit is required to
have at least one room with a minimum of 120 sq ft
(11.2 m2) of total floor area. Other habitable rooms
except kitchens are required to have a minimum of
70 sq ft (6.5 m2) and shall not be less than 7' (2134 mm)
in any horizontal direction. These code requirements
rarely affect home design. One major code requirement
affecting room size governs the space allowed for a
toilet, which is typically referred to as a water closet. A
space 30" (762 mm) wide must be provided for water
closets. A distance of 21" (533 mm) is required in front
of a toilet to any obstruction. A minimum clearance of
21" (533 mm) is also required in front of a bathroom
sink to any obstruction, and a minimum distance
HEADROOM
7'-0" MIN (2134 mm)
5'-0"
(1520 mm)
Chapter 9: Guidelines and Required Codes That Affect Building Design
FLOOR SPACE WITH LESS THAN 5'-0" (1524 mm)
OF CEILING HEIGHT CANNOT BE COUNTED AS
USABLE FLOOR SPACE
FIGURE 98 Minimum ceiling heights for habitable rooms.
of 24" (610 mm) is required in front of a shower. These
sizes can often affect the layout of a small bathroom,
but are rarely a problem in a custom home. Chapter 16
will provide additional information related to the
layout of the bathroom plumbing fixtures.
Ceiling Heights
Habitable rooms, hallways, corridors, bathrooms, toilet
rooms, laundry rooms, and basements must have a
minimum ceiling height of 7'−0" (2134 mm). The bathroom ceiling can be reduced over a counter or plumbing
fixture to 6'−8" (2032 mm). This lowered ceiling can
often be used for lighting or for heating ducts. Beams
that are spaced at a maximum distance of 48" (1219
mm) O.C. are allowed to extend 6" (152 mm) below
the required ceiling height. A shower or tub equipped
with a shower head must also have a minimum ceiling
height of 6'−8" (2032 mm) above a minimum area
of 30" × 30" (762 × 762 mm) at the shower head. In
rooms that have a sloping ceiling, the minimum ceiling
must be maintained in at least half of the room. The
balance of the room height may slope to 5' (1524 mm)
minimum. Any part of a room that has a sloping ceiling
less than 5' (1524 mm) high, or 7'−0" (2134 mm) for
furred ceilings, may not be included as habitable square
footage (see Figure 9-8). Portions of basements that do
not contain habitable space, hallways, bathrooms, toilet
rooms, and laundry rooms shall have a minimum ceiling height of 6'−8" (2032 mm). Beams, ducts, or other
obstructions may project to within 6'−4" (1931 mm) of
the finished floor.
Light, Ventilation, Heating, and
Sanitation Requirements
The light and ventilation requirements of building codes
have a major effect on window size and placement. The
heating and sanitation requirements are so minimal that
161
they rarely affect the design process. The codes covering light and ventilation have a broad impact on the
design of the house. Many preliminary designs often
show entire walls of glass to take advantage of beautiful
surroundings. At the other extreme, some houses have
very little glass and thus no view but very little heat loss.
Building codes affect both types of designs.
Providing Natural Light
The IRC requires that all habitable rooms must have
natural light provided by windows. Kitchens are habitable rooms but are not required to meet the light and
ventilation requirements. Windows for other habitable
rooms are required to open directly into a street, public
alley, or yard on the same building site. Windows may
open into an enclosed structure such as a porch as long
as the area is at least 65% open. Required glazed openings may face into the area under a balcony, bay, deck,
or floor cantilever provided a clear vertical space at least
36" (914 mm) in height is provided. Required glazing is
also permitted to open into a sunroom or covered patio
that abuts a street, yard, or court if more than 40% of the
exterior sunroom walls are open, or enclosed only by
insect screening and the ceiling height of the sunroom is
not less than 7'–0" (2134 mm). Required areas for light
and ventilation may be provided by skylights.
All habitable rooms must have a glazing area equal to
8% of the room’s floor area, and that one-half of the area
used to provide light also be openable to provide ventilation. A bedroom that is 9' × 10' (2743 × 3048 mm) is
required to have a window with a glass area of 7.2 sq ft
(0.66 m2) to meet minimum standards. Another limit to
the amount of glass area would be in locations that are
subject to strong winds or earthquakes. These restrictions will be explored later in this chapter as climatic
and geographic design criteria are discussed.
Alternative Methods of Providing Light
and Ventilation
Two alternatives to the light and ventilation requirements are allowed in all habitable rooms. Mechanical
ventilation and lighting equipment can be used in
place of openable windows in habitable rooms except
bedrooms. Glazing can be eliminated except when
required for emergency egress when artificial light
capable of producing 6 footcandles (6.46 lux) over
the area of the room at a height of 30" (762 mm)
above the floor is provided.
Ventilation can be eliminated when an approved
mechanical ventilation system capable of producing
0.35 air changes per hour is provided for the room.
Ventilation is also waived if a whole-house mechanical ventilation system capable of producing 15 cfm
162
(7.08 L /s) per occupant is provided. Occupancy is
based on two per the first bedroom and one for each
additional bedroom.
The second method of providing lighting and ventilation allows floor areas of two adjoining rooms to be
considered as one if 50% of the area of the common
wall is open and unobstructed. This opening must also
be equal to 10% of the floor area of the interior room or
25 sq ft (2.3 m2), whichever is greater. Openings required
for light and ventilation may be allowed to open into a
thermally isolated sunroom or covered patio. To use this
ventilation option, the openable area between the adjoining rooms must be equal to 10% of the floor area of the
interior room, but cannot be less than 20 sq ft (2 m2).
Although considered nonhabitable, bathrooms and
laundry rooms must be provided with an openable
window. The window must be a minimum of 3 sq ft
(0.3 m2), of which one-half must open. A fan that
provides 50 cfm (24 L/s) for intermittent ventilation
or 10 cfm (10 L/s) for continuous ventilation can be
used instead of a window. These fans must be vented
to outside air. If mechanical ventilation is to be used,
careful consideration must be given to the type and
placement of the intake and exhaust vents. Exterior
vents are required to be protected from local weather
conditions. They must also be covered with corrosionresistant grills, louvers, or screens that have a 1/4"
(6.4 mm) minimum and a 1/2" (12.7 mm) maximum
opening. Intake openings must be located a minimum
of 10' (3048 mm) from hazardous or noxious contaminants, and from any plumbing vents, chimneys,
alleys, parking lots, or loading docks. The minimum
distance can be reduced if the intake vent is placed a 2'
(610 mm) minimum below the contaminant source.
Heating
The heating requirements for a residence are very
minimal. IRC requires a heating unit to be installed in
any residence built in an area where the winter design
temperature is below 60°F (16°C). So unless you’re
building in Hawaii, plan for a heating unit capable of
producing and maintaining a room temperature of
68°F, or 20°C at a point 3' (914 mm) above the floor
and 2' (610 mm) from exterior walls for all habitable
rooms. Portable space heaters can no longer be used to
meet compliance with the current codes. Chapter 21
provides information on sizing heating units.
Sanitation
Code requirements for sanitation rarely affect the
design of a structure. Each residence is required to have
a toilet, a sink, and a tub or shower. A sink is required
to be provided in the kitchen. All plumbing fixtures
Architectural Drafting and Design
must be connected to an approved water supply, and
kitchen sinks, lavatories bathtubs, showers, bidets,
laundry sinks, and washing machines are required to
have hot and cold water. All plumbing fixtures must be
connected to a sanitary sewer or an approved private
sewage disposal system. The room containing the toilet
must be separated from the food preparation area by a
tight-fitting door. Chapter 16 provides further information regarding the layout of each fixture, and Chapter
20 provides information regarding plumbing plans.
Safety Equipment
Major considerations of required safety equipment
include automatic fire sprinkler systems, smoke detectors, and carbon monoxide alarms.
Automatic Fire Sprinkler Systems
Based on the acceptance of the 2009 IRC, automatic
fire sprinkler systems that meet Section P2904 of the
International Plumbing Code (IPC) are required for
all new townhouse construction. A sprinkler system is
not required to additions or alterations made to existing townhomes. As part of the 2009 IRC, effective
January 1, 2011 automatic residential fire sprinklers
must be installed in all new one- and two-family
dwellings. The fire sprinkler systems must be installed
to meet Section P2904 of the IPC or National Fire
Protection Association (NFPA) 13D.
Smoke Detectors
Smoke detectors and alarms provide an opportunity
for safe exit through early detection of fire and smoke.
A smoke alarm that meets the requirements of UL 217
must be installed per NFPA72 in each sleeping room, as
well as at a point centrally located in a corridor that provides access to the bedrooms. For a one-level residence,
a smoke detector must be located:
●
At the start of every hall that serves a bedroom.
● In each sleeping room.
For multilevel homes, a smoke alarm is required on
every floor, including the basement. The smoke alarm
should be located over the stair leading to the upper
level. In split-level homes, the smoke alarm is required
only on the upper level if the lower level is less than one
full story below the upper level. If a door separates the
levels of a split-level home, a smoke alarm is required
on each level. A smoke alarm is required on the lower
level if a sleeping unit is located on that level. Smoke
alarms should not be placed in or near kitchens or
fireplaces because a small amount of smoke can set off
a false alarm.
Chapter 9: Guidelines and Required Codes That Affect Building Design
Smoke alarms must be located within 12" (305 mm)
of the ceiling or mounted on the ceiling. Alarms must
receive their primary power from the building wiring
when the power is served from a commercial source.
When the primary power is interrupted, the alarm
system must be connected to electrical wiring with a
battery-powered backup system. Smoke alarms must
be interconnected so that if one alarm is activated, all
will sound.
Carbon Monoxide Alarms. A carbon monoxide alarm
is required in all new residential construction that contains fuel-fired appliances or has an attached garage.
Alarms that meet UL 2034 must be placed outside of
each separate sleeping area in the immediate vicinity of
the bedrooms in dwelling units. Units must be installed
in accordance with the manufacturer’s instructions.
163
site of the governing building department. Building
codes specify how a building can be constructed to
resist the forces from wind pressure, seismic activity,
freezing, decay, and insects. Each of these areas will
be discussed in detail in later chapters.
NOTE: Because of wide variation in the weather patterns
and the seismic risk across the country, most municipalities
have made alterations to the national code to address local
considerations. A key role of the designer is to verify local
requirements, and ensure that the project exceeds those
standards. In exploring the following variables, the first
two can be taken directly from a table in the code or provided by the building department. The balance of factors
will require information provided by the local jurisdiction.
Ground Snow Load
CLIMATIC AND GEOGRAPHIC
DESIGN CRITERIA
The major influence of the IRC on a structure has to
do with structural components. Chapters covering
foundations, wall construction, wall coverings, floors,
roof-ceiling construction, roof coverings, and chimney
and fireplace construction are provided to specify minimum construction standards. To use the information
in the codes as it relates to each area of construction
requires some basic climatic and geographic information about the area where the structure will be constructed. Key elements that must be known to design
a safe structure include:
●
Air freezing index.
●
Flood hazard.
●
Ground snow load.
●
Mean annual temperature.
●
Ice barrier underlayment.
●
Seismic design category.
●
Susceptibility to damage by frost line depth.
●
Susceptibility to damage by termites.
●
Susceptibility to damage by weathering.
●
Wind design—speed.
●
Wind design—topographic effects.
● Winter design—temperature.
Values for each category will consist of a YES or
NO, or a design value. Information for many of these
categories can be obtained from a table in the IRC.
Other factors need to be determined from the Web
The ground snow load factor will affect the sizes of
structural members. The amount of snow that can be
expected will also be important in planning access to
the structure when the maximum amount of snow is
on the ground. The ground snow load factor can be
determined using maps provided by the IRC. Figure 9-9
shows the ground snow loads for the western portion
of the United States. Zones of the map are designated
by the maximum ground elevation of the zone, and the
snow load to be used in the design for that area. For
instance, in the southeastern corner of California, the
maximum elevation is 1000', and the snow load is zero.
In the southwestern corner of California, the maximum
elevation ranges from 1800', to 2000' and the snow load
ranges from zero to five. In the northeastern corner of
Washington, the snow load is listed as CS. This designation indicates that a site-specific case study must be
preformed. The local building department will generally
be able to provide the snow loads that should be used
to determine the size of building materials as well as the
ground snow that should be planned for as access to the
structure is planned. Buildings designed in areas with a
snow load of 70 pounds per square foot (3.35 kPa) or
less can be constructed using the provisions of the IRC.
In areas that exceed this, the value must be determined
using accepted engineering practice.
Winter Design Temperature
The outdoor design temperature can be determined
from Appendix D of the IPC or from the Web sites of
the local jurisdiction. The winter design temperature
will be important as the heating loads of the home are
considered in Chapter 21.
164
Architectural Drafting and Design
FIGURE 99 Maps similar to Figure R301.2.(5) can be used to determine the snow loads to be used in the selection of
structural members. Courtesy 2009 International Residential Code, Copyright 2009, Washington D.C. International Code Council. Reproduced
with permission. All rights reserved. www.iccsafe.org.
Chapter 9: Guidelines and Required Codes That Affect Building Design
Flood Hazard
It’s not just homes that are built on a riverbank,
oceanfront property, or the banks of a lake that must
be designed to withstand floodwaters. The risk of
flood damage will vary for each region based on several
factors. The amount of rain is a major consideration in
flood risk, but certainly not the most important factor.
Areas of the country such as the Pacific Northwest or the
Gulf states that receive large amounts of rain typically
have drainage systems prepared to handle the runoff.
Areas of the country that are arid often have poor facilities for coping with excess runoff. Designers should
verify with local municipalities which specific areas of
their jurisdiction are prone to flooding, and design the
foundation accordingly. The building department can
provide a date that the area was placed into the National
Flood Insurance Program, and the date for the adoption of the code or ordinance of management of flood
hazard area. This information will help in determining
the design flood elevation height of the floor. Chapter 33
will explore precautions that can be taken based on the
risk of flooding.
Mean Annual Temperature
Based on the mean annual temperature from the
National Climate Data Center, the governing jurisdiction will determine the mean annual temperature.
This information will be used for planning the heating
system as well as calculating the insulation requirements for the building envelope.
Ice Barrier Underlayment
The governing jurisdiction will determine the value
of the ice barrier underlayment based on local history
of damage from the effects of ice damming. For areas
that are required to receive an ice barrier, a barrier
must be provided that meets the requirements of
Section R905.2.7.1 of the IRC. These guidelines will
be covered in Chapter 22 of this textbook as roof construction is explored.
Seismic Design Category
The governing jurisdiction will determine the seismic
design category value based on one of seven categories,
including A, B, C, D0, D1, D2, and E. The IRC specifically addresses construction methods that can be used
in categories C, D0, D1, and D2. Categories A and B
require no special provision, and category E requires
165
construction per the IBC or design by an engineer.
Construction in categories C through D2 requires designing for increasing seismic risk as the risk category progresses. The effects of the seismic category will affect the
construction of roof, wall, floor and foundation assemblies, and will be addressed in Chapter 22, Chapter 27,
Chapter 28, and Chapter 33.
Susceptibility to Damage by Frost
Line Depth
The frost line depth will affect the design and construction of the foundation and will be explored in
Chapter 33. Depending on the frost line depth, the
governing jurisdiction will determine the required
minimum depth of footings below the finish grade.
Susceptibility to Damage by Termites
The governing jurisdiction will determine the need for
protection from termite damage based on the history
of subterranean termite damage. In areas where there
is potential for damage, one of the alternatives from
Section R318 must be provided for controlling damage.
Each method will be presented in Chapter 33 as foundation construction is explored.
Susceptibility to Damage
by Weathering
The general risk of damage due to weathering can be
determined from using the map shown in Figure 9-10.
In areas of the country that have a wide variance in
weather conditions, the governing jurisdiction will
determine the need for weathering protection to the
foundation based on local conditions. Possible weathering zones include negligible, moderate, or severe. As
the risk of weathering increases, a higher strength of
concrete or grade of masonry will be required to reduce
the chance of damage. Concrete weathering will be
explored in Chapter 33.
Wind Design
The effects of wind on a structure will need to be considered in terms of the wind speed and the how the
topography affects the wind.
Speed
The general risk of wind damage can be determined
using a map similar to Figure 9-11 that shows basic
wind speeds. The wind speed values are 3-second gust
speeds listed in miles per hour. Although this map will
166
Architectural Drafting and Design
FIGURE 910 Maps similar to Figure R301.2(3) can be used to determine the risk of damage to the foundation from weathering. Based on the risk, precautions will need to
be taken as the foundation is designed. Courtesy 2009 International Residential Code, Copyright 2009, Washington D.C. International Code Council. Reproduced with permission. All rights reserved.
www.iccsafe.org.
Chapter 9: Guidelines and Required Codes That Affect Building Design
167
FIGURE 911 Several maps are provided in the IRC to represent wind speeds in various portions of the country. Figure R301.2.(4)
can be used to determine the anticipated wind speed in the southern portion of the United States. Speeds are listed as 3-second
gust speeds in miles per hour, assumed at 33' above the ground for exposure C. Based on the speed, precautions will need to be
taken as the roof, wall, and foundation assemblies are designed. Chapter 22, Chapter 28, and Chapter 33 will address these assemblies.
Courtesy 2009 International Residential Code, Copyright 2009, Washington D.C. International Code Council. Reproduced with permission. All rights reserved.
www.iccsafe.org.
168
Architectural Drafting and Design
FIGURE 912 When a structure is built on the upper half of a hill, the assumed wind speed must be increased. Courtesy 2009 International
Residential Code, Copyright 2009, Washington D.C. International Code Council. Reproduced with permission. All rights reserved. www.iccsafe.org.
provide general design guidelines, the governing jurisdiction will determine the actual wind speed based on
local ground conditions referred to as exposures. The
IRC defines four basic exposures including:
●
Exposure A—Large city centers where at least
50% of the buildings have a height in excess of 70'
(21336 mm).
● Exposure B—Urban and suburban areas, wooded
areas, or other terrain with numerous closely spaced
obstructions having the size of a single-family
dwelling or larger.
● Exposure C—Open terrain with scattered obstructions including surface undulations or other irregularities, having heights generally less than 30' (9144
mm), extending more than 1500' (457 m) from the
building site in any quadrant.
● Exposure D—Flat, unobstructed areas exposed to
wind flowing over open water (excluding shorelines
in hurricane-prone regions) for a distance of at least
1 mile (1.61 km).
Once the speed and exposure zones are known, the
structure can be designed to resist the lateral stress
resulting from the wind. Methods of protecting the
structure from wind-borne debris must also be considered. Chapter 32 and Chapter 33 will explore ways
to resist wind loads and protect the structure.
Topographic Effects
The governing jurisdiction will determine the risk
of wind damage based on local historical data documenting structural damage caused by topographic
wind speed-up effects at isolated hills, ridges, and
escarpments that are abrupt changes from the general topography of the area. If a structure is located
in the top half of one of the designated areas, the
basic wind speed must be adjusted upward based on
the values in Figure 9-12.
Chapter 9: Guidelines and Required Codes That Affect Building Design
169
FIGURE 913 The International Energy Conservation Code divides the United States into three major regions and eight climate
zones. These zones are further divided by the expected humidity to be encountered in each zone. Once the climate zone of the
building site is determined, the required insulation and fenestration efficiency can be determined. Courtesy 2009 International
Energy Conservation Code, Copyright 2009, Washington, D.C., International Code Council. Reproduced with permission. All rights reserved.
www.iccsafe.org.
INTERNATIONAL ENERGY
CONSERVATION CODE
Determining the Required
Building Envelope
The 2009 International Energy Conservation Code
(IECC) is published by the International Code Council
and is updated every three years to conform with the
other international codes. The purpose of the IECC is
to regulate the design and construction of the exterior
envelope and selection of heating, ventilation, and airconditioning (HVAC), water heating, electrical distribution and illuminating systems, and equipment required
for effective use of energy in buildings. The exterior
envelope is made up of the elements of a building that
enclose conditioned (heated and cooled) spaces through
which thermal energy transfers to or from the exterior.
This chapter will address the basic IECC requirements
for the building envelope. These requirements can also
be found in Chapter 11 of the IRC. Section 5 of this text
will address methods for improving the environment
inside the building envelope.
The exterior envelope of a residence comprises the
exterior walls, the ceiling, the openings in the walls
and ceiling, and the floor. The IECC refers to the
openings in the envelope as fenestration. How the
envelope is constructed will depend on the climate
zone where the home is to be located. The IECC
divides the United States into three major regions and
eight climate zones that can be seen in Figure 9-13.
The climate zones are based on the wet-bulb temperature of the area. The wet-bulb temperature is a measurement of the environment that reflects the physical
properties of the surrounding air. The measurement
is based on the use of a thermometer that has its bulb
wrapped in cloth that draws moisture from the surrounding air. These zones are further divided by the
expected humidity to be encountered in each zone
170
Architectural Drafting and Design
FIGURE 914 Table 402.1.1 of the IECC defines the minimum insulation and fenestration requirements. Courtesy 2009
International Energy Conservation Code, Copyright 2009, Washington, D.C., International Code Council. Reproduced with permission.
All rights reserved. www.iccsafe.org.
and include A—moist; B—dry; and C—marine. Zones
that do not have a moisture designation are areas
where moisture is deemed irrelevant.
Although this map provides guidelines for the
designer, it’s also important to consult Table 301.1
of the IECC (a very lengthy list of zones by state and
county) or to contact the governing building department to verify specific climate requirements.
General Requirements for Building
the Envelope
The IRC governs the actual construction of the walls,
floor, and ceiling assemblies that will form the building envelope. The IECC and Chapter 11 of the IRC
govern the insulation and fenestration to be used in
completing the envelope. General requirements for
these two areas of construction are specified in IECC
Table 402.1.1 shown in Figure 9-14.
A comparison of envelope components for a home
built in Houston, Texas, in a warm, humid area in
climate zone 2A; Walla Walla, Washington, in a marine
zone 5A; and Grand Forks, North Dakota, in a moist
zone 7 can be seen below.
Envelope
Component
Walla
Houston Walla
Grand
Forks
Fenestration U-factor
0.65
0.35
0.35
Skylight U-factor
0.75
0.60
0.60
Glazed fenestration
0.30
NR
NR
Ceiling R-value
30
38
49
Wood-framed wall R-value 13
20 or 13 +5 21
Mass wall R-value
13/17
4/6
19/21
Floor R-value
13
30
38
Basement wall R-value
0
10/13
15/19
Slab R-value and depth
0
10, 2'
10, 4'
Crawl space wall R-value
0
10/13
10/13
The IECC allows the envelope to be described in
U-factor in lieu of using R-values. U-values can be
determined in the IECC and will not be addressed
in this chapter.
Chapter 9: Guidelines and Required Codes That Affect Building Design
IN UNFINISHED ATTIC SPACES,
INSULATE BETWEEN THE FLOOR JOISTS.
171
INSULATE BETWEEN
CEILING JOISTS.
INSULATE BETWEEN STUDS
AND THE RAFTERS.
INSULATE WALLS BETWEEN LIVING SPACES
AND UNHEATED GARAGES OR STORAGE AREAS.
INSULATE BETWEEN
VAULTED RAFTERS.
EXTEND INSULATION INTO JOIST
SPACE TO REDUCE AIRFLOWS.
INSULATE BETWEEN THE
STUDS OF “KNEE” WALLS.
INSULATE EXTERIOR WALLS
ABOVE GROUND AREA.
INSULATE BETWEEN JOISTS
ADJACENT TO UNHEATED SPACE.
INSULATE ANY PORTION OF
THE FLOOR IN A ROOM THAT
IS CANTILEVERED BEYOND THE
EXTERIOR WALL BELOW.
INSULATE ALL EXTERIOR
WALLS.
EXTEND INSULATION INTO JOIST
SPACE TO REDUCE AIRFLOWS.
CAULK AND SEAL AROUND
ALL WINDOWS AND DOORS.
INSULATE FOUNDATION
WALLS OF CRAWL SPACES
AND PERIMETER PLATES.
INSULATE FOUNDATION WALLS
ABOVE GROUND AREA.
INSULATE FOUNDATION WALLS
IN HEATED BASEMENTS INSIDE
OR RIGID INSULATION OUTSIDE.
INSULATE SLAB FLOORS BUILT
DIRECTLY ON THE GROUND.
GROUND.
INSULATE FOUNDATION WALLS
IN HEATED BASEMENTS.
GROUND.
FIGURE 915 Locations where insulation is required to be installed.
Insulation
Insulation is material used to restrict the flow
of heat, cold, or sound, in the building envelope
keeping the home warmer in winter and cooler in
summer. It saves energy costs, and when properly
installed it helps maintain a uniform temperature
throughout the house. Various types of insulation
are available and will be discussed in Chapter 12.
Figure 9-15 shows the locations where insulation is
required.
Insulation reduces the amount of heat lost through
walls, ceilings, and floors during the winter and
helps keep heat from entering the residence during
the summer. The ability of materials to slow heat
transfer is called thermal resistance. The R-value of
a material is a measure of thermal resistance to heat
flow. The higher the R-value assigned to a material, the greater the insulating ability. Insulation is
critical in helping reduce heat loss, but it must be
combined with proper caulking and construction
methods.
How much insulation a home should have depends
on local and national codes, climate, energy costs,
budget, and personal preference. The IRC and IECC
give minimum required insulation levels and the
U.S. Department of Energy (DOE) provides recommended insulation levels, by zip codes, for walls,
ceilings, floors, and foundations. Recommended
R-values in the ceiling range from R-30 to R-60
depending on the type of heating to be provided
and the climate zone of the home. Vaulted ceilings
can vary from R-22 to R-60. R-13 to R-30 insulation
is recommended for use in floors, although homes
built in some warm climates do not require floor
insulation. Wall insulation levels vary from R-13 to
R-21 depending on the climate. Always confirm the
minimum insulation required by the codes governing your area. In general, better energy efficiency can
be gained by using more insulation.
Fenestration
The listing for glazed fenestration in Figure 9-14
shows the letters SHGC in the column heading and
footnotes. These letters are to represent the phrase
solar heat gain coefficient. SHGC is a ratio of the
solar heat gain entering the space inside the envelope through the fenestration to the incident solar
radiation. Solar heat gain includes solar heat that is
transmitted through the fenestration and energy that
is absorbed radiation.
172
The prescriptive method of installing insulation
according to IECC Section 402.1.1 allows some some
listed ceiling values to be reduced. Ceilings requiring
insulation values of R-38 can be reduced to R-30 if
the uncompressed height of the insulation extends
over the top plate of the exterior walls. If the same
conditions are met, R-49 insulation can be replaced
by R-38 insulation.
Ceilings with No Attic Storage
When insulation values greater than R-30 are
required by Section 402.1.1 of the IECC, the value of
insulation can be reduced to R-30 if the roof/ceiling
assembly does not allow for the the required insulation height. This reduction in insulation R-value is
limited to 500 sq ft (46 m2) or 20% of the total insulated ceiling area, whichever is less.
Mass Walls
The listing for mass walls in IECC Table 402.1.1
refers to concrete block, poured concrete, insulated
concrete form (ICF), masonry cavity, brick, adobe,
earth block, rammed earth, and solid timber logs.
Masonry veneer is excluded from this category. The
requirements for mass walls apply if at least 50% of
the required insulation R-value is part of the wall or
on the exterior side of the wall. Walls that do not
meet this requirement can be insulated to meet the
standards for wood frame walls.
●
The insulation must extend from the floor to the line
of the finish grade. From the grade, the insulation
must extend an additional 24" (610 mm) vertically
along the wall, or along the grade in the crawl space.
When placed horizontally along the soil in the crawl
space, the insulation must be laid over a continuous
vapor retarder. Other requirements for placing the
vapor retarder will be covered in Chapter 28 and
Chapter 33.
Basement Walls
The walls of basements that are part of the building
envelope must be insulated from the top of the wall
to the basement floor. Basement walls that surround
unconditioned air do not need to be insulated if the
floor supported by the wall is insulated. If the floor is
uninsulated, the basement wall must be insulated to
the same standards as walls surrounding rooms with
conditioned air.
Slab-on-Grade Floors
The edge of concrete slabs that are at, or within 12"
(305 mm) of the grade must be insulated. The insulation can be placed on the inside or outside face of the
concrete wall. Insulation extending away from the
slab must be protected by a minimum of 10" (254
mm) of soil similar to the footing in Figure 9-16A
and Figure 9-16B.
C
SILL
SEAL
FLASHING
PROTECTION
BOARD
RIGID
INSULATION
C
12" MIN.
Ceilings with Attic Storage
The insulation must be permanently attached to the
stem wall.
12" MAX.
The IECC/IRC provides specifi criteria to supplement
the general information provided in Figure 9-14.
The specific requirements are divided by ceilings
with attics, ceilings without attics, walls, floors, and
fenestration.
●
10"
Specific Requirements for Building
the Envelope
Architectural Drafting and Design
FOUNDATION
PERIMETER
B
Floor/Crawl Space Walls
Typical floor insulation methods place the insulation so that it will be in permanent contact with the
underside of the floor decking. The IECC allows the
floor to be uninsulated, and the walls of the crawl
space to be insulated. To use this insulation method,
the crawl space can not be vented to outside air,
and the insulation is required to meet the following
placement guidelines:
4" SCREENED AND
WASHED GRAVEL OR
CRUSHED STONE
A
INSULATION DETAIL
HORIZONTAL
INSULATION PLAN
FIGURE 916A Insulation placement for frost-protected footings. Courtesy 2009 International Residential Code, Copyright 2009,
Washington, D.C., International Code Council. Reproduced with permission. All rights reserved. www.iccsafe.org.
173
GOING
GREEN
Green Codes
Building codes address how the environment affects a
structure. Stresses resulting from gravity, wind, snow,
water, and seismic activity have always been a major
concern of the model codes. The National Green
Building Standard ICC 700 now addresses how the
building affects the environment. The ICC and the NAHB
have jointly developed the National Green Building
Standard that provides a common national benchmark
for designers. Although primarily aimed at residential
construction, the standard does apply to multifamily
construction. The standard requires designers and
builders to address:
• Energy conservation.
• Indoor and outdoor air quality.
In addition to the Green Building Standard, the ICC
and the U.S. Green Building Council (USGBC) have
signed a Memorandum of Understanding between the
two organizations in order to further green building
practices. Because green code development is such a
fluid area, it is imperative that you constantly monitor
the Web sites of the ICC, USGBC, and NAHB for the most
current information on green building and developing
codes. Another great source of green building information can be found at the joint Cengage-ICC portal
titled The Green Destination: Essential Information for
Green Building. The address for each site is listed at the
end of this chapter.
• Land conservation.
• Water conservation.
• Material resource conservation.
MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
HORIZONTAL INSULATION
R
R-VALU
Ec,e
HORIZONTAL INSULATION DIMENSIONS
PER FIGURE R403.3(1) (INCHES)
AIR FREEZING INDEX
(°F-DAYS)b
VERTICAL INSULATI
A ON
R-VALUE c,d
ALONG WALLS
AT CORNERS
A
B
C
1500 or less
4.5
NR
NR
NR
NR
NR
2000
5.6
NR
NR
NR
NR
NR
2500
6.7
1 .7
4.9
12
24
40
3000
7.8
6 .5
8.6
12
24
40
3500
9.0
8 .0
11.2
24
30
60
4000
10.1
10.5
13.1
24
36
60
For SI: 1 inch ⫽ 25.4 mm,°C ⫽ [( °F)-32]/1.8.
a. Insulation requirements are for protection against frost damage in heated buildings. Greater values may be required to meet energy conservation standards. Interpolation between values is permissible.
b. See Figure R403.3(2) for Air Freezing Index values.
c. Insulation materials shall provide the stated minimum R-values under long-term exposure to moist, below-ground conditions in freezing climates. The
following R-values shall be used to determine insulation thicknesses required for this application: Type II expanded polystyrene—2.4R per inch; Type
IV extruded polystyrene—4.5R per inch; Type VI extruded polystyrene—4.5R per inch; Type IX expanded polystyrene—3.2R per inch; Type X extruded polystyrene—4.5R per inch. NR indicates that insulation is not required.
d. Vertical insulation shall be expanded polystyrene insulation or extruded polystyrene insulation.
e. Horizontal insulation shall be extruded polystyrene insulation.
FIGURE 916B Minimum insulation requirements for a concrete slab. Courtesy 2009 International Residential Code, Copyright 2009,
Washington, D.C., International Code Council. Reproduced with permission. All rights reserved. www.iccsafe.org.
174
Architectural Drafting and Design
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you keep current with changes in floor plan related
materials.
Major Building Code Organizations
Company, Product,
Address
or Service
www.afanda.org
www.thegreendestination.com
www.steel.org
www.iccsafe.org
Cengage/ICC -essential
information for green
building.
The International Code
Council (ICC)—The 2009
IRC is their current code;
the 2012 codes are coming
in the spring of 2012.
United States and Federal Agencies Related
to Construction
Address
www.access-board.gov
www.ada.gov
www.eren.doe.gov
www.epa.gov
www.nara.gov/fedreg
www.nist.gov
www.osha.gov
Company, Product,
or Service
The Access Board—U.S.
Architectural and
Transportation Barriers
Compliance Board
Americans with
Disabilities Act
DOE—Department of
Energy’s Energy Efficiency
and Renewable Energy
Network
EPA—U.S. Environmental
Protection Agency
Federal Register—
Government Printing Office
NIST—National Institute
of Standards and
Technology
OSHA—Occupational
Safety & Health
Administration
The following sites are listed in the IBC and IRC for
their reference standards that the codes are based on.
See the IRC for additional references.
Address
www.aamanet.org
www.aci-int.org
Company, Product,
or Service
American Architectural
Manufacturers Association
American Concrete Institute
www.aisc.org
www.aitc-glulam.org
www.ansi.org
www.asce.org
www.asme.org
www.astm.org
www.aws.org
www.awpa.org
www.apawood.org
www.pwgsc.gc.ca.cgsb
www.cedarbureau.org
www.gypsum.org
www.iso.org
www.masonrysociety.org
www.naamm.org
www.nahb.org
www.ncma.org
www.nfpa.org
www.post-tensioning.org
www.pci.org
www.spri.org
www.steeljoist.org
www.seinstitute.org
www.tpinst.org
American Forest & Paper
Association
American Institute of Steel
Construction
American Institute of
Timber Construction
American Iron and Steel
Institute
American National
Standards Institute
American Society of Civil
Engineers
American Society of
Mechanical Engineers
American Society of Testing
Materials—International
American Welding Society
American Wood-Preservers
Association
APA—Engineered Wood
Association
Canadian General Standards
Board
Cedar Shake and Shingle
Bureau
Gypsum Association
International Standards
Organization
The Masonry Society
National Association
of Architectural Metal
Manufacturers
National Association of
Home Builders
National Concrete Masonry
Association
National Fire Protection
Association
Post-Tensioning Institute
Precast Prestressed Concrete
Institute
Single-Ply Roofing Institute
Steel Joist Institute
Structural Engineers
Institute
Truss Plate Institute
Chapter 9: Guidelines and Required Codes That Affect Building Design
www.ul.com
www.usgbc.org
www.wdma.com
Underwriters Laboratories
U.S. Green Building Council
Window and Door
Manufacturers Association
www.wirereinforcementinstitute.org
175
www.approvals.org
www.asfconline.org
www.mbinet.org
Wire Reinforcement, Inc.
Construction-related organizations that ensure the
quality of materials include:
Address
www.csa.ca
Company, Product,
or Service
Canadian Standards
Association
www.nibs.org
www.nmhc.org
www.wwpa.org
International Approval
Services, Inc.
International Association of
Fire Chiefs (IAFC)
Modular Building Institute
(MBI)
National Institute
of Building Sciences
(NIBS)
National Multi-Housing
Council (NMHC)
Western Wood Products
Association
Conservation and Environmental
Design and Construction Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper or complete the electronic chapter test on
the Student CD.
Question 9–9 Are bathrooms in a single-family
residence required to be handicapped accessible?
1. Letter your name, Chapter 9 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer.
You do not need to write out the question. Answers may
be prepared on a word processor if course guidelines
allow it.
3. Answers should be based on the code that governs your
area, unless otherwise noted.
Question 9–11 What are the minimum size requirements
of spiral stairs?
Question 9–12 For a bedroom that is 10' × 12', what
area is required to provide the minimum ventilation
requirements?
Question 9–1 What is the minimum required size for an
entry door?
Question 9–14 For a sloping ceiling, what is the lowest
height allowed for usable floor area?
Question 9–2 List the five major building codes used
throughout the United States that govern residential
construction, starting with the code that governs
your area.
Question 9–15 What is the minimum size opening for
an emergency egress?
Question 9–3 All habitable rooms must have what
percent of floor area in glass for natural light?
Question 9–17 Visit the Web site of the building
department that governs residential construction in your
area. Determine the following current design criteria:
Question 9–4 What is the required width for hallways?
Question 9–5 What is the minimum width for residential
stairs?
Question 9–6 What is the minimum ceiling height for a
kitchen?
Question 9–7 What is the maximum height that
bedroom windowsills can be above the finish floor?
Question 9–8 Toilets must have a space how many
inches wide?
Question 9–10 List three sanitation requirements for a
residence.
Question 9–13 List the minimum square footage
required for habitable rooms.
Question 9–16 What is the minimum required size for
an exterior door?
a. Roof live loads
b. Wind pressure
c. Risk of weathering
d. Frost line depth
e. Snow loads
f. Seismic design category
g. Risk of termites
176
Question 9–18 Determine the climate zone of the area
where your school is located.
Question 9–19 What wind and seismic factors will
influence window placement in the initial home
design?
Question 9–20 How does the IECC define fenestration?
Question 9–21 What components comprise the exterior
envelope of a home?
Question 9–22 List the required R-value for the building
components of the envelope for your climate zone.
Architectural Drafting and Design
Question 9–23 Visit the Web site of the agency
that regulates your state’s building code. List
and describe any code changes currently under
consideration.
Question 9–24 Visit the Web site of one of the testing
labs and obtain information related to a class drawing
project.
Question 9–25 Visit the Web site of one of the regulatory
agencies that influence construction in your area and
describe your findings.
CHAPTER 10
Room Relationships
and Sizes
I
N
T
R
O
D
U
C
T
I
O
N
Architecture probably has more amateur experts than any other
field. Wide exposure to houses causes many people to feel that
they can design their own house. Wide media exposure to
home design programs on Home and Garden Television (HGTV)
and the availability of home improvement retail stores such as
Lowe’s and Home Depot that offer in-store seminars and product demonstrations, have produced educated consumers with
an increased sensitivity to design. Because they know what they
like, many people attempt to draw their own plans, only to have
them rejected by building departments. Designing can be done
by almost anyone. Designing a home to meet a variety of family
needs takes more knowledge.
THE FLOOR PLAN
As a home is designed for a family, the floor plan is usually the first drawing that is started. The floor plan must
be designed to harmonize with the site and the inhabitants. Planning for the site is introduced in Chapter 13
through Chapter 15. The balance of this chapter will
introduce both the design process and basic requirements for a home.
Clients typically provide the designer with many
pictures collected from years of planning, which can
be very helpful in planning for the family’s needs and
lifestyle. Many architectural firms have a written questionnaire to provide insight into how the structure will
be used. Important design considerations include the
following factors:
●
The number of inhabitants.
● The ages and gender of children.
● Future plans to add onto the dwelling.
● A list of general family activities to be done in the
home.
● Entertainment habits.
● Desired number of bedrooms and bathrooms.
● Kitchen appliances desired.
● Planned length of stay in the residence.
●
Live-in guests or requirements for people with
disabilities.
● The budget for the home.
● The style of the home.
● Neighborhood covenants, conditions, and restrictions (CC&R).
It is helpful to have clients write out a specific list of
requirements including minimum number of rooms,
minimum size of each room, and a listing of how
each room is to be furnished. The written list is an
excellent way to have the clients agree on the design
criteria before the design team spends hours pursuing
unwanted features. Providing minimum room sizes is
also much more helpful than allowing a client to request
“three big bedrooms.” An understanding of how the
room is to be furnished will also help the designer be
sure that the owner has realistic expectations for the size
of the room. It is also helpful to have clients provide a
“wish list” of items for their residence. These items can
be eliminated if the budget is exceeded, but it may be
possible to provide them.
Once this information has been provided, the design
process described in Chapter 1 can be started. The
bubble drawings and preliminary sketches will need to
integrate the living, sleeping, and service areas, as well
as movement among these areas. Consideration must
also be given to the style of the home. Single-level and
multilevel homes pose different design challenges.
This chapter will explore the challenges of placing
the living, sleeping, and service areas in various styles
of homes.
LIVING AREA
The living area consists of the living, dining, family,
den, and nook areas. These are the rooms or areas of
a house where family and friends will spend most of
their leisure time. The rooms of the living area should
be clustered together near the entry to allow easy access
for guests.
177
178
Architectural Drafting and Design
Entries
Entries serve as a transition point between areas of
the home. A well-planned home will have at least two
points of entry—the main entry, to draw guests into the
home, and a service entry that is used by the family for
access between the garage, yards, and service areas.
Main Entry
The main entry, as in Figure 10-1, provides an outside focal point to draw guests to the front door and
serves as a hub for traffic to the living areas. A raised
entry is a common method of accenting the front
door. Figure 10-2 shows an example of a simple but
inviting entry that clearly draws guests to the home. Both
examples clearly define access to the front door. The
entry should be kept proportional to the entire structure
and should be made of compatible materials. The size
of the entry will be influenced by the number of entry
doors and their size. Single entry doors are generally 3'
(900 mm) wide. Larger homes may have doors that are
42" (1050 mm) or 48" (1200 mm) wide. Double doors
are typically 5' (1500 mm) or 6' (1800 mm) wide, and
one or both panels can be operable. Single and double
doors are usually 6'–8" (2000 mm) high but are also
available in 8' (2400 mm) and custom heights.
NOTE: Review Chapter 9 for code requirements for egress
doors located on the egress path.
A second major consideration in planning the entry
is providing protection from the weather. Depending on
your area of the country, this might include direct sunlight (in arid climates), rain, snow, and wind. A wellplanned entry will provide a covered access into the
FIGURE 101 The main entry should provide a focal point
from the outside of the home to draw guests to the front door.
Courtesy Janice Jefferis.
FIGURE 102 A simple but inviting entry can clearly draw guests
to the home. Courtesy Paul Helus.
home as well as a windbreak. The windbreak can often
be achieved by recessing the entry area similar to the
home in Figure 10-3. The depth of the recess should be
kept proportional to the width and height of the entry.
FIGURE 103 This recessed, covered entry provides protection
from the weather and blends well with the balance of the home.
Once inside the foyer, guests should have direct access to other
living areas of the home, and have close access to a coat closet.
Courtesy Mike Jefferis.
Chapter 10: Room Relationships and Sizes
179
GREAT RM.
REFR.
DN. 3
RISERS
MAST. SUITE
LINEN
SKYLIGHT
STUDY
KITCHEN
several people at a time. The size will be based on the
client’s needs and personal preferences, as well as the
size and cost of the home. In a small home, a foyer
48" (1200 mm) wide may be tolerable, although 6' ×
6' (1800 × 1800 mm) is still considered small. In
a larger home, a room 8' to 12' (2400 to 3600 mm)
wide would be more appropriate. The height of the
foyer should be considered as the size is determined.
A small foyer with a tall ceiling will create a feeling
of being in an elevator shaft. Remember, the goal of
the foyer is to create a warm, inviting feeling and
to enhance traffic flow throughout the home (see
Figure 10-4).
Service Entry
FOYER
DINING RM.
COVERED
PORCH
BRICK
COLUMN
The service entry similar to Figure 10-5 links the garage,
kitchen, utility room, bathrooms, and patios or decks.
In many homes, although guests typically use the main
entry, the family’s main access is through the service
entry. Depending on the size and location of the home,
the service entry may serve as a mudroom. The service
entry will be discussed later in this chapter as utility
rooms are explored.
36" HIGH
PLANTER
FIGURE 104 The foyer should create a warm, inviting feeling
and enhance traffic flow throughout the house. Courtesy Tereasa
Stark Designs.
Foyer
The foyer is typically the first access to the residence
for guests. In cold climates, many homes have an
enclosure that leads to the foyer, to prevent heat loss.
The ideal entry will open to a foyer rather than directly
into one of the living areas. The foyer serves as a place
for welcoming guests or saying final good-byes. The
foyer also provides access to the living areas, the sleeping area, and the service areas of the house. This might
include a hall leading to the sleeping area and a stair
way leading to an upper or lower floor. A closet should
be provided near the front door for storage of outdoor
coats and sweaters, space for guests’ coats, as well as
room for seasonal clothing. Provide access to the closet
that will not be blocked by opening the front door.
The area must provide ample room to open the entry
door completely and allow it to swing out of the way of
people entering the home.
The foyer should be proportional to the rest of the
home, but it should also be of sufficient size to hold
FIGURE 105 The service entry is used to link the service areas
to the exterior. Courtesy David Jefferis.
180
Living Room
The purpose of the living room will vary, depending on
the size of the home and the preferences of the home
owner. Points to consider in planning the living room
include how the room will be used, how many people
will use it, how often it will be used, and the type and
size of furniture that will be placed in it. Some families
use the living room as a place for quiet conversation
and depend on other living areas for noisier activities.
In homes designed to appeal to a wide variety of interests, the formal living room has given way to a large
multipurpose room.
If both a living room and a family room are provided, the living room is typically used to entertain
guests or for quiet conversations. Figure 10-6 shows
a formal living room. If the home has no family room,
the living room will also need to provide room for
recreation, hobbies, and relaxation.
The size of the living room should be determined
by the number of people who will use it, the furniture
intended for it (see Figure 10-7A), and the budget for
the entire construction project. Rectangular rooms are
typically easier to plan for furniture arrangements. The
closer a room is to being square, the harder furniture
placement becomes. The minimum width needed for
common activities is 12' to 14' (3600 to 4200 mm).
A room 13' × 18' (3900 × 5400 mm) works well for
most furniture arrangements and allows for moving
furniture easily. Figure 10-7B lists common sizes of
living room furniture.
Architectural Drafting and Design
Within the room, an area approximately 9'
(2700 mm) in diameter should be provided for the
primary seating area. This area is often arranged to take
advantage of a view or centered on a fireplace. In smaller
homes, the living room can be made to seem larger if it
is attached to other living areas as in Figure 10-8A.
In larger residences similar to Figure 10-8B, the living
room is often set apart from other living areas to give it
a more formal effect.
The living room is usually placed near the entry
so that guests may enter it without having to pass
through the rest of the house. The living room
should also be placed so that the rest of the home
can be accessed without having to pass through it.
Many designers place the living room one or more
steps below the level of the balance of the home, as
in Figure 10-9, to enhance a feeling of separation
and to discourage through traffic. The location of
the room should also take energy efficiency into
consideration. If the room is used primarily in the
evening, it should be placed on the west side of the
residence so it will have natural light at that time. In
cooler climates, a southwestern orientation will provide the most hours of sunlight; in warmer climates
a northwestern orientation will help the room take
advantage of evening light while offering some protection from the low summer sun. The overhang of
roofs, wall projections, type and amount of glazing,
and landscaping can all be used to control the effects
on the structure. Figure 10-10 shows a casual living
room that is open to both the rest of the home and
to the yard.
Family Room
FIGURE 106 A formal living room provides an area for quiet
conversation away from the noise of other living areas. In
larger homes, the living room is often set apart from the rest
of the living areas to create a formal area. Courtesy Piercy & Barclay
Designers, Inc., CPBD.
The family room is probably the most used area of
a house. A multipurpose area, it is used for such
activities as watching television, informal entertaining, sorting laundry, playing pool, or eating. With
such a wide variety of possible uses, planning the
family room can be quite difficult. The room needs
to be separated from the living room but still
be close enough to have easy access from the
living, dining, and kitchen areas for entertaining.
Figure 10-11 shows a possible layout of living areas
providing close but separate rooms. The family room
needs to be near the kitchen because it is often used
as an eating area. Placing the family room adjacent
to the kitchen combines the two most used rooms
into one area called a country kitchen. It is also
common to have the family room near the service
areas of the residence.
Chapter 10: Room Relationships and Sizes
181
LIVING / FAMILY ROOM
SOFA
DESK & CHAIR
COMPUTER
WORKSTATION
END TABLE
OVAL
END TABLE
LOVE SEAT
ENTERTAINMENT
CENTER COMPONENTS
TELEVISION
END TABLE
COFFEE
TABLE
RECLINER
GRANDFATHER
CLOCK
END TABLE
CORNER
TABLE W/ LAMP
SHELF UNIT
HALL TREE
STEREO CABINET
STUFFED CHAIR
OTTOMAN
FLOOR LAMP
SECRETARY
POOL TABLE
PING-PONG TABLE
FOOSBALL TABLE
GRAND PIANO
PIANO
DINING ROOM
DINING ROOM TABLES
SERVING CART
CHINA HUTCH
BUFFET
CURIO
DINING CHAIR
BEDROOM
DRESSER
BUREAU
CRIB
BUNK
TWIN
DOUBLE
FIGURE 107A Furniture typically found in living areas.
QUEEN
KING
NIGHTSTAND
182
Architectural Drafting and Design
COMMON FURNITURE SIZES (INCHES)
LIVING ROOM AND FAMILY ROOM
Sofas
34 ⫻ 78
End
34 ⫻ 90
34 ⫻ 96
Tables
34 ⫻ 102
18 ⫻ 18
Armchairs 18 ⫻ 21
18 ⫻ 24
18 ⫻ 30
18 ⫻ 24
22 ⫻ 24
18 ⫻ 36
28 ⫻ 32
24 ⫻ 24
32 ⫻ 34
Sectional
26 ⫻ 30
26 ⫻ 26
Pieces
26 ⫻ 53
26 ⫻ 62
24 hex
26 hex
Recliners
to 66
24 ⫻ 56
Piano
Love
Seats
32 ⫻ 50
Coffee
30 ⫻ 66
Tables
30 ⫻ 29
18 ⫻ 36
20 ⫻ 52
Grand
20 ⫻ 60
Piano
58 ⫻ 75
FIGURE 108A If the living room is open to other living areas, a
casual feeling is created. Courtesy Aaron Jefferis.
the family room, the room should be large enough
to allow for the heat from the stove. Often in an
enclosed room where air does not circulate well, the
area around a stove or fireplace is too warm to sit
near comfortably.
20 ⫻ 75
DINING ROOM
Oval Tables
54 ⫻ 76
Hutch
18 ⫻ 36 ⫻ 72
Round Tables
30
Chairs
18 ⫻ 18
18 ⫻ 20
32
36
42
48
Rectangular
Tables
Tea Cart
16 ⫻ 24
18 ⫻ 33
30 ⫻ 34
36 ⫻ 44 to 108
42 ⫻ 48 to 108
BEDROOM
Dressers
18 ⫻ 30 to 82
Desks
24 ⫻ 30
24 ⫻ 35
Beds:
Crib
30 ⫻ 54
Bunk
30 ⫻ 75
Twin
39 ⫻ 75
24 ⫻ 42
32 ⫻ 42
Double
54 ⫻ 75
32 ⫻ 48
32 ⫻ 60
Queen
60 ⫻ 80
King
76 ⫻ 84
Nightstands
12 ⫻ 15
15 ⫻ 15 to 21
FIGURE 107B Common furniture sizes.
Sizes can vary greatly depending on the design
criteria for the residence. When the family room
is designed for a specific family, its size can be
planned to meet their needs. When the room is
being designed for a house where the owners are
unknown, it must be of sufficient size to meet a
variety of needs. An area of about 13' × 16' (3900 ×
4800 mm) should be the minimum. This is a small
room but would provide sufficient area for most
activities. If a wood-burning stove or fireplace is in
FIGURE 108B In addition to being open, this area creates an
elegant room in which to entertain. Courtesy Eric S. Brown Design
Group, Inc. Photo by Oscar Thomson.
Chapter 10: Room Relationships and Sizes
183
Dining Room
FIGURE 109 Many designers place the living room one or
more steps below the level of the rest of the home to enhance
a feeling of separation and to discourage through traffic.
Courtesy Sara Jefferis.
For most families, space should be provided for
an entertainment center storing the television, the
stereo system, and related equipment. Figure 10-12
shows a pleasing arrangement of a fireplace, a television, and entertainment units.
Dining areas, depending on the size and atmosphere
of the residence, can be treated in several ways. The
dining area is often part of, or adjoining, the living
area, as in Figure 10-13. For a more formal eating
environment, the dining area will be near but separate
from the living room area. See Figure 10-14A and
Figure 10-14B. The two areas are usually adjoining
so that guests may go easily from one to the other
without passing through other areas of the house. The
dining room should also be near the kitchen for easy
serving of meals but without providing a direct view
into the work areas of the kitchen. Because of the need
to be by the living room and kitchen, the dining room
is often placed between these two areas or in a corner
between the two rooms, as in Figure 10-15.
A casual dining room can be as small as 9' × 11'
(2700 × 3300 mm) if it is open to another area. This
size would allow for a table seating four to six people
and a small storage hutch. A formal dining room should
be about 11' × 14' (3300 × 4200 mm). This allows
room for a hutch or china cabinet as well as the table
and chairs. Allow for a minimum of 32" (800 mm) from
the table edge to any wall or furniture for placement of
chairs and a minimal passage area. A space of approximately 42" (1050 mm) will allow room for walking
around a chair when it is occupied.
Nook
When space and finances will allow, a nook or breakfast
area is often included in the design. This is where the
family will eat most meals and snacks (Figure 10-16).
The dining room then becomes an area for formal eating
only. Both the dining room and the nook need to be
near the kitchen. If possible, the nook should also be
near the family room.
Where space is at a premium, these areas are often
placed together in one room called a grand or great
room (Figure 10-17). In larger homes a patio or deck
may be enclosed to provide a solarium (Figure 10-18).
Den/Study/Office
FIGURE 1010 A casual living room that draws the outside
in. Living areas of this residence are close to each other for
easy entertaining, but separated for noise control. Courtesy
Eric S. Brown Design Group, Inc. Photo by Lawrence Taylor.
Although the name may vary, many families plan for a
room for quiet reading and study, as in Figure 10-19.
This room is typically located off the entry and near the
living room. The den often serves as a buffer between
the living and sleeping areas of a residence. In many
tract houses, the den is used as a spare bedroom or
guest room.
184
Architectural Drafting and Design
PATIO
NOOK
9/0 X 11/0
LIVING AREA
SH
EL
VE
S
WALK IN CLOSET
LINEN
LAUNDRY
11/3 X 6/2
FURN
D
SHOWER
PANTRY
BO
O
K
W.H.
M. BATH
LIVING
13/4 X 17/4
WOOD
STOVE
W
MASTER BEDRM
18/0 X 16/8
KITCHEN
10/0 X 12/0
FAM. RM.
15/0 X 17/4
WOOD
STORAGE
SPA TUB
COFFERED
CLG.
LIVING AREAS
TUB/SHR
BATH
LIN.
STORAGE
CLO.
DINE
11/6 X14/0
ENTRY
BEDRM 2
10/8 X 12/2
BEDRM 3
11/6 X 12/2
WINDOW SEATS
W/ STORAGE
3 CAR GARAGE
43/0 X 27/0
PLANTER
FIGURE 1011 Living areas of this residence are close to each other for entertaining, but separated for noise control. Courtesy Wally
Griener, SunRidge Designs, CPBD.
FIGURE 1012 A pleasing arrangement of fireplace, television,
and display and storage units should be part of every family
room. Courtesy Jordan Jefferis.
FIGURE 1013 The dining area can be combined with other
living areas to create a spacious environment. Courtesy Piercy &
Barclay Designers, Inc., CPBD.
Chapter 10: Room Relationships and Sizes
185
DN. 3
RISERS
GREAT RM.
KITCHEN
PANTRY
ENTRY
DINING RM.
11'-10" x 15'-3"
CURIO CAB.
BUILT-IN
CHINA
HUTCH
9'-0" CEIL
GARAGE
12'-0" HIGH
CEILING
FIGURE 1014A Separating the dining room from the other
living areas creates a more formal eating area. Courtesy Tereasa
Stark Designs.
If the room is to be a true office within the home,
the entrance should be directly off the entry. An entry
separate from the residence is ideal. Entry to the office
can be provided from a covered porch but should be
distinctive enough so that clients will know where to
enter. The size of the office depends on the equipment
to be used and the number of clients to be accommodated. It should have room for a desk, computer work
space, storage areas for books and files, and a separate
area for phones, fax, and photocopying machines.
Home Theaters
Although not included in most tract homes, personal
theaters or media rooms are becoming popular in
many custom homes. What used to be unfinished
space, or a bonus room above a garage, can be made
into a home theater. Home theaters are customdesigned rooms created, as the name implies, for
high-quality viewing of movies. The home designer
will work closely with media consultants to meet the
needs of the family and to help plan the locations of
sound equipment. Figure 10-20 shows four common
room layouts for home theaters with surround sound.
FIGURE 1014B Although open to other rooms, a formal
atmosphere is created by enclosing the dining area with columns and arches. Courtesy Eric S. Brown Design Group, Inc. Photo by
Lawrence Taylor.
Points to consider will be the size and type of the
television, the number of viewers, and the type of
seating. A wall-mounted digital or plasma television
will require far less room than a projection television
or even a big-screen television. While most home theaters are designed for eight to twelve people similar
to Figure 10-21, larger capacity rooms are occasionally found. Sofas, recliners, and easy chairs make for
casual, comfortable seating. Theater-type seating is
also available. For larger seating groups, an inclined
or stepped floor should be part of the design. No
matter how small the room, space should be provided
for snack preparation. Items that may be included are
a popcorn machine, a counter with a microwave, and
a small refrigerator or wet bar.
SLEEPING AREA
The age, gender, and number of children will determine how many bedrooms will be required. Preteens
can share a bedroom if space is limited. Teens of the
same gender have even been known to survive sharing
186
Architectural Drafting and Design
LIVING AREA
LIVING RM.
PATIO
MASTER BEDRM
14/0 X 16/0
14/8 X 13/0
DINING RM.
12/0 X 14/6
SPA
M. BATH TUB
PANTRY
WALK IN
CLOSET
KITCHEN
11/0 X 12/6
TU
D
BATH
B/
SH
R
LINEN
SHOWER
BEDRM 2
11/0 X 11/0
FIGURE 1017 A grand or great room is a combination of a
living, dining, and family room. Courtesy Marvin Windows and Doors.
W
FUR W.H.
ENTRY
DEN/BEDRM
2 CAR GARAGE
13/6 X 11/4
20/0 X 22/0
FIGURE 1015 Combining the dining and living areas provides
ample space for entertaining. Courtesy Wally Griener, SunRidge
Designs, CPBD.
a room together, although this situation often results
in distinctive markings of territory during tense times.
The ideal situation is to provide a separate bedroom for
each child. Each room should have space for sleeping,
relaxation, study, storage, and dressing.
FIGURE 1016 A nook is a casual area for family dining. Courtesy
Megan Jefferis
FIGURE 1018 A sunroom or solarium can provide added
square footage at a relatively low construction cost. Courtesy
American PolySteel.
FIGURE 1019 Many homes provide a room that can be used
as an office, study, or guest bedroom. Courtesy Eric S. Brown Design
Group, Inc. Photo by Lawrence Taylor.
Chapter 10: Room Relationships and Sizes
187
CENTER
DIPOLAR
LISTENING
AREA
FRONT
MONOPOLAR REAR
SUBWOOFER
LARGE LISTENING AREA
FIGURE 1021 Many custom homes include a personal theater
as part of the design. Courtesy BOWA Builders, Inc. Greg Hadley,
photographer.
LISTENING
AREA
L-SHAPED ROOM
LISTENING
AREA
ELONGATED ROOM
LISTENING
AREA
SMALL LISTENING AREA
FIGURE 1020 Four common room layouts for a home theater.
Bedrooms
The sleeping area consists of the bedrooms. These
rooms should be placed away from the noise of the
living and service areas and out of the normal traffic
patterns. The number of bedrooms will vary depending
on the size of the family and the ages of the children.
Even in a family with no children, a minimum of two
rooms should be provided. A second bedroom can be
used as an office, craft room, or guest room and greatly
increases the value of the home for resale. Most homes
have a minimum of three bedrooms; and four bedrooms
and a den are a common option for many subdivision
homes. Many custom homes plan for a space about the
size of a bedroom to be used as a multipurpose room.
An exercise or equipment room, a game room, and a
darkroom are common types of multipurpose rooms
located near the bedrooms.
The arrangement of bedrooms will vary greatly
depending on the needs of the family. Common arrangements include placing all the bedrooms together, or
placing the master bedroom separate from the bedrooms for children. It is also common in custom homes
to plan a bedroom–living unit for long-term care of a
live-in relative.
Bedrooms are generally located with access from a
hallway for privacy from living areas and to be near
bathrooms, as in Figure 10-22. Care must be taken
to keep the bathroom plumbing away from bedroom
walls. One way to accomplish this is to place a closet
between the bedroom and the bath. If plumbing must
be placed in a bedroom wall, use insulation to help
control noise.
Bedrooms function best on the southeast side of the
house. This location will bring morning sunlight to
the rooms. When a two-level layout is used, bedrooms
are often placed on the upper level, away from the
living areas. Not only does this arrangement provide a
quiet sleeping area, but bedrooms can often be heated
by the natural convection of heat rising from the
living area. Another option is placing the bedrooms
188
Architectural Drafting and Design
SEW / BED 4
11'-0" X 12'-6"
BED 3
13'-2" X 11'-0"
FOLD-DN.
IRON'G BD.
TUB. & S.
NOOK
11'-0" X 13'-4"
DESK
COVERED
PATIO
LINEN
BED 2
16'-5" X 11'-0"
SHOWER
FIGURE 1022 Bedrooms should be located with access from a
hallway, for privacy from the living areas, and be near bathrooms.
Courtesy Tereasa Stark Designs.
in a daylight basement. An advantage of a bedroom in
a daylight basement is the cool sleeping environment
that the basement provides. Care must be taken in
basement bedrooms to provide direct emergency exits
to the outside.
Sizes of bedrooms vary greatly depending on the size
of the home, the age of the occupants, and the furniture
to be placed in a bedroom. The International Residential
Code (IRC) requires a minimum of 70 sq ft (6.5 m2).
Homes financed by Federal Housing Authority (FHA)
loans are required to provide a minimum of 100 sq ft
(9.3 m2). Spare or children’s bedrooms are often as small
as 9' × 10' (2700 × 3000 mm). This might be adequate
for a sleeping area, but not if the room is also to be used as
a study or play area. Each bedroom should have enough
space for a single bed, a small bedside table, and a dresser.
Clients often specify enough space for a twin or double
bed. Plan for a minimum of 24" (600 mm) on each side
of a bed, where space to walk is required. A space of
approximately 36" (900 mm) should be provided
between dressers and any obstruction to allow for opening of drawers or doors. This requires a space of about
12' × 14' (3600 × 4200 mm) plus closet areas. Minimum
closet space will be covered in the next section.
FIGURE 1023 A well-designed master suite provides spacious
room for a queen- or king-sized bed, a fireplace, a sitting area, direct
access to the wardrobe and bathing areas, and access to a private
deck or balcony. Courtesy Zachary Jefferis.
area, and bathing area. A well-designed master suite, as
in Figure 10-23, provides spacious room for a queen- or
king-sized bed, plus room for a fireplace, sitting area,
direct access to the wardrobe and bathing areas, and
access to a private deck or balcony.
The master bedroom should be at least 12' × 14'
(3600 × 4200 mm) plus closet areas. An area of 13' × 16'
(3900 × 4800 mm) will make a spacious bedroom
suite, although additional room is required for a sitting or reading area (Figure 10-24). A window seat
Master Suites
More than just a room for sleeping, the master bedroom in many custom homes is a retreat from the day’s
troubles. The master suite serves as a bedroom, sitting
FIGURE 1024 A master suite often includes a sitting area for
quiet reading or conversation. Courtesy Marvin Windows and Doors.
Chapter 10: Room Relationships and Sizes
can often be used to provide sitting room without
greatly increasing the square footage of the room.
Try to arrange bedrooms so that at least two walls can
be used for bed placement. This is especially important in the master bedroom to allow for periodic
furniture movement.
Window planning is very important in a bedroom.
Although morning sun is desirable, space should be
planned so that sunlight will not shine directly on
the bed. Especially important in planning windows
for a bedroom is to allow for emergency egress from
the bedroom. Review Chapter 9 for a summary of
emergency egress requirements for bedrooms. For
upper-level bedrooms, try to provide a roof, porch, or
balcony as an escape route from a window for young
children. A flexible escape ladder can be used for
older children.
Closets
Building codes do not require bedroom closets. FHA
recommends a length of 48" (1200 mm) of closet
space for males and 72" (1800 mm) for females. Six
feet (1800 mm) should be considered the practical
minimum for resale if a traditional shelf-and-pole
storage system is to be used for storage. Space can be
reduced if closet organizers are used. Minimum closet
depth is typically considered to be 24" (600 mm). A
depth of 30" (750 mm) is adequate to keep clothing
from becoming wrinkled. If a closet must be small, a
double-pole system can be used to double the storage
space or a premanufactured closet organizer can be
used to provide storage. Closets can often be used as a
noise buffer between rooms or located in what would
be considered wasted space in areas with sloping ceilings. Space must also be provided near the bedrooms
for linen storage. A space 2' (610 mm) wide and 18"
(457 mm) deep would be minimal.
189
FIGURE 1025 An area containing shelves, baskets, and
drawers increases storage without increasing square footage.
Courtesy Matthew Jefferis.
equipment and fold-down ironing boards are provided
in the closet similar to Figure 10-26. Figure 10-27
shows a well-planned wardrobe area for a master suite.
Many clients request space for a freestanding armoire
to provide additional storage.
Walk-In Closets
Master bedrooms, as well as the other bedrooms of
a custom home, often will have a walk-in closet. It
should be a minimum of 6' × 6' (1800 × 1800 mm)
to provide adequate space for clothes storage. A closet
of 6' × 8' (1800 × 2400 mm) provides much better
access to all clothes. Providing multiple rods for
hanging pants, shirts, skirts, and blouses can increase
storage. A single pole should be provided for hanging
dresses and seasonal coats. An area containing shelves,
baskets, and drawers, as in Figure 10-25, is also
desirable if space permits. In large closets, a seating
area should be provided, and in some cases, laundry
FIGURE 1026 In large closets of a custom home, laundry equipment and fold-down ironing boards are provided in the master
bedroom closet. Courtesy Tom Worcester.
190
Architectural Drafting and Design
36" HIGH COUNTER
W/ DRAWERS BELOW
S& P
S & DBL. P
3 SHELVES W/
GLASS DOORS
OVER COUNTER
LINEN
FULL
MIRROR
SEAT
SHOE
SHELVES
BUILT-IN IRON
S & DBL.P
LINEN
KNEE
SPACE
BED. 1
21'–6" X 17'–0"
FIGURE 1027 A well-planned wardrobe provides ample storage space for hanging and folded clothes and easy access to
the bedrooms and bathrooms.
SERVICE AREAS
The bathrooms, kitchen, utility rooms, and the garage
are each considered part of the service area. Notice
that three of the four areas have plumbing. Because
of the plumbing and the services that each provides,
an attempt should be made to keep the service areas
together. Another consideration in placing the service
area is noise. Each of these four areas tends to have
noises that will interrupt activities of the living and
sleeping areas.
Bathrooms
FIGURE 1028A A bathroom suite typically includes the features
of a full bath with a separate shower. Courtesy Janet Helus.
Although many adults prefer only a shower, families with younger children often require a tub unit.
A bathroom suite typically includes the features of a
full bath with a separate tub and shower similar to
Figure 10-28A. The tub is often an enlarged tub or
spa similar to Figure 10-28B. If the tub is to be raised,
skid-proof steps should be provided. If windows are
To provide privacy, bathrooms are often reached by
a short hallway, apart from living areas. A house with
only one bathroom to serve the living area and the kid’s
bedrooms must have it located for easy access from both
the living and sleeping areas. Access to the bathroom
should not require having to pass through the living or
sleeping areas.
Types of Bathrooms
Options for bathrooms include half-bath, three-quarter
bath, full bath, and bathroom suite. A half-bath has
a lavatory and a water closet (a toilet). A half-bath is
usually provided near the living area to serve guests.
A three-quarter bath combines a shower with a toilet
and a lavatory. Three-quarter baths are often used near
bedrooms for older children. A full bath has a lavatory, a
toilet, and a tub or a combination tub-and-shower unit.
FIGURE 1028B A bathroom suite typically includes a spa or a
large soaking tub separate from the shower. Courtesy Lee Gleason.
Chapter 10: Room Relationships and Sizes
191
LINE OF LOWER FLOOR
U.L. APP'D METAL CHIMNEY
6' X 4' CER. TILE
SPA AND SURROUND
MAKE-UP
COUNTER
COVERED
DECK
SEAT
S&P
OPEN
SHELVES
GLASS
BLOCK
BED. 2
OPEN SHELVES
LIN
WARDROBE
W/ CLOSET
ORGANIZER
LIN
3
GU 6" H
AR IGH
DR
AIL
FIGURE 1029 Master bath suite.
placed around a tub or spa, the glass is required to
be tempered. Glass blocks are a common alternative
to tempered glass. The wardrobe, dressing area, and
a sitting area are also usually part of, or adjoining,
the bathroom suite. Figure 10-29 shows a plan view
for a master suite. Many custom homes feature a
full bath with an adjoining exercise room, sauna, or
steam room.
Bathroom Locations
The style of the house affects the number and locations of bathrooms. A single-story residence may have
one bathroom for the master bedroom and a second to
serve the living areas and the other bedrooms. A twostory house typically has two full bathrooms upstairs,
with a minimum of a half-bath downstairs. Multilevel
homes should have a bath on each level containing
bedrooms or a half-bath on each level with any type
of living area.
When a residence has two or more baths, they
are often placed back-to-back or above each other
to reduce plumbing costs. A full bath is typically
provided near the master bedroom, with a separate
bathroom to serve the balance of the bedrooms. If
space and budget allow, a bathroom for each bedroom is desirable. For families with young children,
a tub is usually a must. Many bathrooms that are
designed to be shared place the sinks in one room,
and the toilet and tub in an adjoining room similar
to Figure 10-30A and Figure 10-30B. For homes
designed to appeal to a wide variety of families,
a combination of a tub and shower is often used.
Homes designed for outside activities often have a
three-quarter bath near the utility room or combine
the laundry facilities with a bathroom to create what
is often called a mudroom.
SEAT
10'–6" X 10'–4"
OPEN STORAGE
IN ATTIC SPACE
BED.1
48" X 60"
C.T. SHW.
W/ SEAT
& 2 HDS.
S&P
BED. 3
10'–6" X 10'–0"
AR
CH
SEAT
60" F.G.
TUB & S.
DN. 14 R.
34" HIGH RAIL
36" HIGH
RAIL
LINEN
S&P
22 X 30 MIN.
ATTIC ACCESS
FIGURE 1030A Many bedrooms share a bathroom. When the
lavatories are separated from the bathing area, two people can
use the room at once.
Kitchen
A kitchen is used through most of a family’s waking
hours. It not only serves for meal preparation but
often includes areas for eating, working, and laundry
(see Figure 10-31). It needs to be located close to the
dining areas so that serving meals does not require
extra steps. The kitchen should also be near the family
room. This will allow those preparing meals to be part
of family activities. When possible, avoid placing the
kitchen in the southwest corner of the home. This
location will receive the greatest amount of natural
sunlight, which could easily cause the kitchen to overheat. Because the kitchen creates its own heat, try to
place it in a cooler area of the house unless venting
and shading precautions are taken. One advantage of a
FIGURE 1030B By placing the lavatory in each bedroom, a
room containing the toilet and shower can be placed between
two adjoining bedrooms.
192
Architectural Drafting and Design
Kitchen Work Areas
The space within the kitchen also demands great
consideration. Perhaps the greatest challenge facing
the designer is to create a workable layout in a small
kitchen. The National Kitchen & Bath Association
(NKBA) considers any kitchen with less than 150 sq ft
(13.9 m2) as a small kitchen and a kitchen with greater
than 150 sq ft (13.9 m2) as a large kitchen. Layout
within the kitchen includes the relationship of the
appliances to the work areas. The main work areas of
a kitchen are those for storage, preparation, and cleaning. Each can be seen in the plan in Figure 10-33.
FIGURE 1031 The kitchen is used for meal preparation and is
often a place for eating and a social hub at family gatherings and
parties. Courtesy Eric S. Brown Design Group, Inc. Photo by Lawrence Taylor.
western placement is the natural sunlight available in
the late evening.
In a house for a family with young children, a
kitchen with a view of indoor and outdoor play areas is
a valuable asset. This will allow for the supervision of
playtimes and control of traffic in and out of the house.
The kitchen is often closely related to the utility area.
Because these are the two major workstations in the
home, a kitchen close to the utility room can save valuable time and energy as daily chores are done. It is also
helpful to place the kitchen near the garage or carport. A
location similar to the layout in Figure 10-32 will allow
groceries to be unloaded easily.
VAULTED
CLG.
PATIO
NOOK
11/0 X 8/7
KITCHEN
DINING RM.
CARPET HARD
FAMILY RM.
WOOD
16/6 X 15/2
REC. ROOM
19/6 X 16/2
12/6 X 16/2
ARCH
ENTERTAINMENT
CENTER
DESK
FREEZER W.H.
FURN
ALLISON
EASY SWING
LINE OF
FLOOR
ABOVE
ENTRY
UTIL.
3 CAR GARAGE
31/0 X 25/9
PANTRY
W
UP16 RI SE RS
STORAGE
COFFERED
CLG.
34'' HIGH
HANDRAIL
VAULTED CLNG
LIVING RM.
14/6 X 17/6
D
FIGURE 1032 For efficient living, the kitchen must be near the
dining, living, family, and utility areas and the service entry. If traffic must flow through the kitchen, it should not pass through the
work triangle. Courtesy Wally Griener, SunRidge Designs, CPBD.
Storage Areas. The storage areas consist of the refrigerator, the freezer, and cabinet space for food and
utensils. Most families prefer to have a refrigerator in
the kitchen, with a separate freezer in the mudroom,
laundry, or garage. Storage for cans and dried foods is
typically in base cabinets 24" (600 mm) wide or in a
pantry unit, similar to Figure 10-34A and Figure 10-34B.
Upper units 12" (30 mm) deep are also typically used
for dishes and nonperishable foods. A minimum counter surface 18" (450 mm) wide should be provided
next to the refrigerator to facilitate access to it (see
Figure 10-35). This area can also be useful for preparing snacks if the width is increased to approximately
36" (900 mm). As the size is increased, this counter can
also be used to store appliances, such as mixers and
blenders in an appliance garage similar to the one
shown in Figure 10-36. This is a useful area for a breadboard and a drawer for silverware storage. Additional
drawer space could be used for mixing bowls, baking
pans, and other cooking utensils. Enclosed cabinet
space should also be provided for storage of cookbooks, writing supplies, and telephone books, similar
to Figure 10-37. The NKBA recommends that the main
storage area include at least five of the following items
located 15" to 48" (375 to 1200 mm) above the finished
floor. The items useful for storage include lowered wall
cabinets (see Figure 10-34B), raised base cabinets, tall
cabinets (see the center of Figure 10-37), appliance
garage (see Figure 10-36), bins (see Figure 10-38A),
racks, swing-out pantry closets, interior vertical dividers, specialized drawers, and pullout shelves.
Preparation Areas. The main components of the
preparation areas are the sink, cooking units, and a
clear counter work space. Clear counter work space
should be placed near the storage areas, sink, and cooking areas with a minimum of one counter that provides
approximately 48" (1200 mm) of work space. This
length should be increased to 72" (1800 mm) if two
or more people will be involved in preparing a meal.
Chapter 10: Room Relationships and Sizes
193
TRASH COMP.
APPL. GARAGE
SINK & G.D. W/
GARBAGE DISP.
DOWNDRAFT STOVE
OPEN SHELVES
BUILT-IN MICRO.
DISHWASHER
36" HUTCH
APPLIANCE GARAGE
REFR.
EXISTING
WALL TO BE
REMOVED
OPEN SHELVES
FREESTANDING
ANTIQUE REFR.
LINE OF 9'
CEILING
OPEN SHVS
TILE FLOOR
S&P
DRY
BRM.
BOOK
WASH
'0' CLEARANCE KIT
WOOD COOK STOVE
36 X 18 X 14"
HIGH SEAT W/
WOOD BOX
FIGURE 1033 A well-planned kitchen will provide preparation areas, storage areas, and
cleaning areas separated by adequate counter space. These areas are generally not specified
on the floor plan except to denote specific appliances required for each area. Related information is specified on the interior elevations (Chapter 26). Figure 10-34 through Figure 10-39
show features of this kitchen.
FIGURE 1034A A pantry should be located in or near the
kitchen to provide storage for dry and canned goods. This
walk-in closet, located between the kitchen and garage, uses
shelves, bins, and pullout drawers for long-term storage.
Courtesy Janice Jefferis.
FIGURE 1034B Storage cabinet located in the kitchen. The
cabinet has pullout shelves and drawers for storage of foods for
daily use. Because the cabinet is located just to the left of the
baking center, the lower drawers provide convenient storage
for large pans and other baking utensils. Courtesy Norm Holtzer.
194
FIGURE 1035 The refrigerator is used for the short-term cold
storage of food. A counter 18” (457 mm) wide should be provided next to the refrigerator. Courtesy Janice Jefferis.
FIGURE 1036 An appliance garage can be placed between the
countertop and the upper cabinet to store small appliances that
are used on a regular basis. Courtesy Janice Jefferis.
FIGURE 1037 Cookbooks can be stored and antique kitchen tins
can be displayed in this storage cabinet. Courtesy Leonard Conklin.
Architectural Drafting and Design
FIGURE 1038A The cooking center of this home includes a
downdraft stove, a microwave, and preparation areas on each
side of the stove. Storage includes open upper cabinets for
spices, hanging storage for common utensils, and enclosed
upper cabinets for cooking supplies. The counter provides
space for storage of baking supplies. Lower cabinets feature
breadboards on each side of the stove, and drawers and doors
for storage. The drawers on the right side of the stove have
false fronts for the display of dry food items such as lentils,
beans, and corn. Courtesy Janice Jefferis.
The preparation center can be placed between the
primary sink and the cooking unit, between the refrigerator and the primary sink, near a secondary sink, or
in an island. Each work area should have a counter at
least 18" (450 mm) wide. Specific requirements will
be introduced as each appliance is discussed. Large
kitchens often have a small vegetable sink in the
preparation area and a larger sink for cleaning utensils. A minimum size for a vegetable sink is 16" × 16"
(400 × 400 mm).
The cooking appliances are usually a stove that
includes both an oven and surface heating units or
separate appliances for baking and cooking and a microwave oven. Custom kitchens similar to Figure 10-38B
often include warming drawers for maintaining foods
at the desired temperature during meal preparation or
for warming bread. The microwave oven can be part
of a built-in oven, mounted below the upper cabinets,
placed on the counter, or placed below the counter. A
minimum counter space of 18" (450 mm) should be
placed on each side of a stove or oven unit to prevent
burns and provide temporary storage while cooking.
Figure 10-38A shows a cooking center; Figure 10-38B
shows a cooking center using a double oven.
Cleaning Center. The cleaning center typically
includes the sink, garbage disposal, and dishwasher,
as in the arrangement shown in Figure 10-39. The
sink and the surrounding cabinets and counter space
Chapter 10: Room Relationships and Sizes
195
FIGURE 1039 The kitchen sink is the hub of the cleaning center.
Located near windows providing a view of the outside entertainment areas, the sink is flanked by a trash compactor on the left and
a dishwasher on the right. Storage for dishes is provided above
the dishwasher. The drawers provide storage for eating utensils
and other basic kitchen supplies. Courtesy Janice Jefferis.
FIGURE 1038B A double oven is a popular choice for the main
cooking unit. It can include two standard ovens, a standard oven
and a convection oven, or a microwave over either a standard or
convection oven. A microwave and a warming drawer complete
this cooking center. Courtesy Barbara Conklin.
are the most heavily used work area of the kitchen, so
this area should be centrally located.
Most clients prefer a double sink rather than a
single sink. A typical double sink is 32" × 21" (800 ×
525 mm), but 36" (900 mm) and 42" (1050 mm)
wide units are also available. Double sinks are also
available, at 90 degrees to each other for use in a
corner. If the sink is connected to a public sewer, a
garbage disposal can be installed to one side of the
sink to eliminate wet garbage. A garbage disposal
should not be used on sinks connected to septic
tanks. The NKBA recommends that if a kitchen
contains only one sink, the sink should be located
across from the cooking surface, preparation center,
or the refrigerator, or between these items. It also
recommends that a clear floor space of 30" × 48"
(750 × 1200 mm) be provided in front of the sink
and the dishwasher. A minimum area 36" (900 mm)
wide should be provided on one side of the sink for
stacking dirty dishes, and about 24" to 30" (600 to
750 mm) on the other side for clean dishes. The
dishwasher can be placed on either side of the sink,
depending on the client’s wishes. The dishwasher
should be placed within 36" (900 mm) of the edge
of the sink. A minimum of 21" (525 mm) of clear
floor space should be allowed between the edge of the
dishwasher and cabinets or appliances that are placed
at right angles to the dishwasher to allow loading and
unloading. An upper cabinet should be provided near
the dishwasher to store dishes.
The Work Triangle
The mere fact that a kitchen is big and has all the
latest appliances does not make it efficient. Designing
a functional kitchen requires careful consideration of
the relationship between the work areas. This relationship, referred to as the work triangle, is a key aspect of
kitchen ergonomics. The work triangle is formed by
drawing lines from the centers of the storage, preparation, and cleaning areas similar the kitchen drawing
in Figure 10-33. This triangle outlines the main traffic
area required to prepare a meal. Food will be taken
from the refrigerator, cleaned at the sink, and cooked
at the microwave or stove, and then leftovers will be
returned to the refrigerator. Using this work pattern
and considering the work triangle, good design places
the work centers at approximately equally spaced points
of the triangle connected by counters. General rules for
efficient kitchen design include:
●
Always place work space between each workstation
of the triangle.
● No side of the work triangle should be less than 4'
(1200 mm) or greater than 7' (2100 mm).
196
●
●
Architectural Drafting and Design
The sum of the sides of the work triangle should
be at least 15' (4500 mm) but not more than 22'
(6600 mm).
Avoid kitchen arrangements that cause traffic to flow
through the work triangle.
Keep in mind that these are only guidelines—a
large kitchen consists of more than just three appliances or workstations. The triangle may need to be
modified to accommodate doors or to preserve a
view. Appliances such as convection ovens, grills,
microwave ovens, multiple sinks, and even multiple
refrigerators will all affect the arrangement of work
areas and appliances.
In addition to traffic within the kitchen, the relationship of the kitchen to other rooms also needs
to be considered. If care is not taken in the design
process, the kitchen can become a hallway. The
kitchen needs to be in a central location, but traffic must flow around the kitchen, not through it.
Figure 10-40 shows the traffic pattern in three different kitchens.
DW
REFR
PAN
REFR
PAN
STRAIGHT (ONE-WALL)
DW
FOOD BAR
PENINSULA
REFR
DW
DW
FOOD BAR
DESK
BRM
REFR
DESK
PAN
ISLAND
PAN
CORRIDOR
PAN
REFR
DW
REFR
DW
L-SHAPED
U-SHAPED
FAMILY
REFR
REFR
DW
DW
PAN
FIGURE 1041 The sum of the three sides of the work triangle
must be between 15" to 22" (4500 to 6600 mm) for an efficient
work pattern.
Common Counter Arrangements
PAN
FAMILY
A. NO THROUGH TRAFFIC
DINING
B.THROUGH TRAFFIC WITH
MINOR INTERRUPTIONS
FAMILY
REFR
DESK
DW
PAN
DINING
C.THROUGH TRAFFIC WITH
MAJOR INTERRUPTIONS
FIGURE 1040 Traffic flow should never disrupt the working area
of a kitchen; plan A accomplishes this. Plan B allows traffic through
the kitchen, but it will not disrupt work. Plan C shows traffic that will
be very disruptive.
Designers typically use one of six common counter
arrangements to define the work triangle: straight (one
wall), corridor, L-shape, U-shape, peninsula, and island
(see Figure 10-41). Each arrangement presents its own
design challenges.
Straight. The straight-line or one-wall kitchen layout
is ideal when appliances must be placed in a very small
space. This type of layout is often used in a small apartment, a mother-in-law unit, or a recreation room that
is on a different floor from the main kitchen. Although
this arrangement requires few steps to move between
appliances, it also provides a very limited amount of
cabinet space and work areas. This arrangement can be
improved, however, by using a movable cart or cutting
block to expand the work triangle.
Corridor or Galley. The corridor or galley arrangement
places all of the cabinets on two parallel walls. This
arrangement is a great improvement over a straight-line
kitchen because it allows convenient storage, provides
ample counter space in a small area, and minimizes
Chapter 10: Room Relationships and Sizes
197
walking distance in the triangle. The distance between the
cabinet faces should be a minimum of 48" (1200 mm).
A width of 54" to 64" (1350 to 1600 mm) will allow
two or more cooks to use the kitchen simultaneously.
A galley kitchen is usually placed between two living
areas. This arrangement is appropriate for a small
home but should not be used in larger homes because
of the possibility of poor traffic flow. Unless an alternative route is provided, the galley kitchen will become a
thoroughfare for room-to-room traffic.
L-Shape. An L-shaped cabinet arrangement is suitable for both small and large kitchens, but it loses
efficiency as the size of the kitchen increases. Cabinets
are placed on two adjacent walls with two workstations placed along one wall and the third workstation
placed on the remaining wall. The L-shape enables
efficient travel between workstations that are located
close to the right angle, but the arrangement loses its
effectiveness as the legs of the L become longer. This
type of cabinet arrangement eliminates traffic through
the work area and is well suited to kitchens that are
adjacent to great rooms.
U-Shape. The U-shaped cabinet arrangement provides an efficient layout with easy access between
workstations. It also eliminates through traffic unless
a door is placed in one of the walls. Many designers
consider the U-shape ideal for a large kitchen, but it
can result in hard-to-reach storage areas in the corners. The U arrangement may also seem confining in
a small kitchen. A minimum space of 60" (1500 mm)
should be used between cabinet faces. As the distance
increases, an island or peninsula can be added to
improve the cabinet arrangement.
Peninsula. A peninsula arrangement provides ample
cabinet and work space by adding one additional leg to
an L-shaped or U-shaped kitchen. The peninsula can be
used as work space, as the location for a work center, as
a food bar, or as a combination of these features.
Island. An island similar to Figure 10-42 can be added
to any of the other five cabinet arrangements. The island
can be used to provide added counter space or work
space. A range or cooktop, or a small sink, is often
placed in the island. A minimum of 42" (1050 mm)
should be provided between the island and other
counters to allow for traffic flow around the island. If
the island contains an appliance such as a range, 48"
(1200 mm) should be the minimum distance provided
between counters, to allow for traffic flow when the
oven door is open.
FIGURE 1042 An island can be used to increase work areas. This
island also includes a lowered food bar. Courtesy Tereasa Jefferis.
Counter and Cabinet Sizes
The standard kitchen counter is 36" (900 mm) high.
The NKBA recommends that at least two different
counter heights be provided in the kitchen with one
work area ranging from 28" to 36" (700 to 900 mm)
and a second area ranging from 36" to 45" (914 to
1143 mm) above the finish floor. For custom homes,
the height may be adjusted to meet the physical needs
of the owners, but it is important to remember that
radical changes from the norm may greatly limit
resale value. Common cabinet dimensions are listed
in Table 10-1.
If a food bar is provided in a peninsula or island,
consideration must be given to the height and width of
the eating counter. Common heights include 30", 36",
and 42" (750, 900, and 1050 mm). Widths range from
12" to 18" (300 to 450 mm). For a 30" (750 mm) high
counter, allow a space 30" wide × 18" deep (750 ×
450 mm) for each person seated at the counter. When
the food bar is level with the main countertop, allow at
least a 15" (375 mm) deep clear space for the counter.
When the food bar is above the main counter height,
allow at least a 12" (300 mm) deep clear space for the
food bar. Figure 10-43 shows an example of each type
198
Architectural Drafting and Design
Overhead Cabinets
Base Cabinets
Standard
depth
12" (300 mm)
24" (600 mm)
Maximum
depth
18" (450 mm)
36” (900 mm)
Height
30" to 33" (750 to 825 mm)
when placed above
countertop
36" (900 mm)
floor to
countertop
12" to 18" (300 to 450 mm)
when placed above an
appliance
Width
9" to 48" (225 to 1200 mm) 9" to 48" (225 to
Stock cabinets are available 1200 mm) Stock
in 3" (75 mm) increments
cabinets are available in 3" (75 mm)
increments
Location
15" (375 mm) above
countertop
24" (600 mm) above sink
30" (750 mm) above range
TABLE 101 Cabinet Dimensions
of food bar located in a peninsula. If a counter 30"
(750 mm) high is provided, chairs can be used with it.
The other heights will require stools for seating. When
the food bar is the same height as the other counters, the
counter area will seem much larger than when two
different heights are used. A width of 12" (300 mm)
will provide sufficient space for eating. If the food bar is
higher than the other kitchen cabinets, it can be used as
a visual shield to hide clutter in the kitchen.
be placed to promote easy movement between work
areas. The sink should be near the cooking units and the
refrigerator to facilitate the preparation of fresh foods.
Provide a minimum of 48" (1200 mm) between counters to accommodate someone working at the sink and
another person walking behind him or her. Try to avoid
placing the sink and dishwasher on different counters,
even if they would be just around the corner from each
other. Such a layout often leads to accidents from water
dripping onto the floor.
Refrigerator. Typically a space 36" (900 mm) wide is
provided for the refrigerator similar to Figure 10-35.
If a built-in or refrigerator similar to the unit in
Figure 10-44 is used, a space ranging from 36" to 48"
(900 to 1200 mm) wide × 24" to 28" (600 to 700 mm)
deep × 84" (2100 mm) high should be allowed. To
ease unloading of groceries, the refrigerator should be
placed near the service entry. The refrigerator should
be placed at the end of a counter, so that it will not
divide the counter into small work spaces. If it must
be placed near a cabinet corner, allow a minimum of
15" (375 mm) in the corner for access to the back of
Arrangement of Appliances
Many home owners prefer the sink to be located in
front of a window, but a location with a view into other
living areas is also popular. Placement of the sink at a
window allows for supervision of outdoor activities and
provides a source of light at this workstation. Because of
its placement at a window, the sink is often located first
as the kitchen is being planned. The sink should also
42" HIGH FOOD BAR
36" HIGH FOOD BAR
30" HIGH FOOD BAR
FIGURE 1043 Common arrangements of food bars.
FIGURE 1044 If a home is to include a built-in refrigerator,
the designer will need to verify the exact size of the unit to be
used. Courtesy Dick Schmitke.
Chapter 10: Room Relationships and Sizes
199
used. Cooktops are available in widths of 30", 36", 42",
and 48" (750, 900, 1050, and 1200 mm). Oven units
are typically 27", 30", or 33" (675, 750, or 825 mm)
wide. The bottom of the oven is typically 30" (750 mm)
above the floor. Avoid placing a stove next to a refrigerator, a trash compactor, or a storage area for produce
or breads.
FIGURE 1045 Many homes use a range combining all of the
cooking needs in one central location. Courtesy Sam Griggs.
Microwave. A microwave unit may be placed above
the oven unit, but the height of each unit above the
floor should be considered in regard to the height of
the clients. A microwave mounted with the bottom of
the appliance between 30" to 48"(750 to 1200 mm)
above the floor and near the daily eating area often
proves to be very practical. Provide a counter 15"
(375 mm) wide beside the microwave for placing hot
dishes coming out of the unit.
the counter. A minimum of 15" (375 mm) of counter
space should be provided on the latch side of a singledoor refrigerator, and on both sides of a side-by-side
unit. If space cannot be provided adjacent to the
refrigerator, provide a counter within 48" (1200 mm)
across from the refrigerator. The location must also be
convenient for access to the sink for food preparation
and to the cooking areas for food storage. The refrigerator should be placed within 60" to 72" (1500 to
1800 mm) of both the sink and the cooking center. If
possible, it should be placed so that the door will not
block traffic through the work triangle. Avoid placing
the refrigerator beside an oven.
Breadboard. In addition to the major kitchen appliances, care must be given to other details such as
breadboards, counter work spaces, and specialized
storage areas. The breadboard should be placed near
the sink and the stove but not in a corner. Ideally, a
minimum of 15" (375 mm) of counter space can be
placed between appliances to allow for food preparation. Specialized storage often needs to be considered
to meet clients’ needs. These needs will be covered as
cabinets are explained in Chapter 26.
Range. The cooking units should be located near the
daily eating area. The range, similar to Figure 10-45,
should be placed so that the person using it will not
be standing in the path of traffic flowing through the
kitchen. This will reduce the chance of hot utensils
being knocked from the cooking elements. Ranges
should be placed so that there is approximately 18"
(450 mm) of counter space between the unit and the
end of the counter to prevent burns to people passing
by. If a food bar is provided behind and at the same
height as the cooking surface, provide a minimum
space of 9" (225 mm) behind the cooking surface.
Stoves should not be placed within 18" (450 mm) of an
interior cabinet corner. This precaution will allow the
oven door to be open and still allow access to the interior cabinet. A walkway 48" (1200 mm) wide should
be provided to allow someone to walk behind a person
working at the stove.
For most kitchens a cabinet or an under-cabinet rack
similar to Figure 10-46A is adequate for wine storage.
In custom homes, a special room may be requested for
storing wine. Although this is referred to as a wine
cellar, it could be as simple as a small, insulated closet
near the kitchen or family room, a small storage area
located under a stairwell, or an environmentally controlled room specifically designed for the storage of
fine wines. The location and size will vary based on
the budget, the number of bottles to be stored, and
the availability of a basement. A temperature of 55°F,
a relative humidity of 60% to 65%, and low exposure
to ultraviolet light exposure are ideal for long-term
wine storage. The cool temperature slows the aging
process, while the high humidity prevents moisture
inside the wine bottle from moving into the cork and
eventually evaporating into the air. Placing the wine
storage area in a naturally cool location such as a basement may eliminate the need for a cooling unit. While
some basements in northern climates may naturally
provide these conditions, the basements of most
Cooktop. A cooktop and oven should be within three
or four steps of each other if separate units are to be
Wine Cellar
200
FIGURE 1046A An under-counter wine storage area is
common in many kitchens. Courtesy Judy Schmitke.
homes are too warm and dry to passively provide the
ideal conditions for wine storage. Most storage units
require the use of a wine cellar cooling unit. Wine cellars installed above ground will require active conditioning to achieve the ideal wine cellar environment.
Figure 10-46B shows a small wine cellar.
Utility Room
The room that is called a utility room or mudroom
should be planned to include space for washing,
drying, folding, mending, ironing, and storing clothes.
Additional space is often used for long-term storage of dry and canned food, as well as for a freezer.
Figure 10-47 shows a small utility room. In a wellplanned clothing center, a means of hanging wet clothing should be provided in addition to the standard
clothes dryer. A counter for folding and storing clean
clothes as well as a closet for hanging clothes as they
come out of the dryer should also be included. A built-in
ironing board should be provided as well. Figure 10-48
shows common items found in a utility room.
Utility rooms are often placed near either the bedrooms or the kitchen area. There are advantages to
Architectural Drafting and Design
FIGURE 1046B A wine cellar can be located in an insulated
room near the kitchen or family room, or in a cool area of the
basement. Courtesy Karen Griggs.
both locations. Placing the utility room near the bath
and sleeping areas puts the washer and dryer near
the primary source of laundry. Care must be taken to
insulate the sleeping area from the noise of the washer
and dryer.
Placing the utilities near the kitchen allows for a
much better traffic flow between the two major work
areas of the home. A utility room near the kitchen can
often provide space for additional kitchen storage. In
smaller homes, the laundry facilities may be enclosed
in a closet near the kitchen. In warm climates, laundry
equipment may be placed in the garage or carport. In
homes with a basement, laundry facilities are often
placed near the water heater source. Many home owners
find that laundry rooms in a basement are too separated
from the living areas. If bedrooms are on the upper floor,
a laundry chute to the utility room can be a nice convenience. The utility room often has a door leading to the
exterior. This allows the utility room to function as a
mudroom. Entry can be made from the outside directly
into the mudroom, where dirty clothes can be removed.
This allows for cleanup near the service entry and helps
keep the rest of the house clean. Figure 10-49A shows
Chapter 10: Room Relationships and Sizes
201
DINING
DW
KIT
REFR
5 SHELVES
UTIL
WASH
DRY
GARAGE
LT
FIGURE 1049A The utility room may serve as a service entry
where dirty clothes can be removed as the home is entered.
FIGURE 1047 A small utility room near the kitchen can be used
for additional kitchen storage as well as for washing, drying, and
folding clothes. Courtesy Cary Gleason.
this type of utility layout. Another common use for a
utility room is to provide an area for sewing and ironing
similar to Figure 10-49B.
Bonus Room
budget allows. Many plans show this space as unfinished attic space, but plan for future conversion to
living area as the need arises. The unused attic can be
turned into living space similar to that in Figure 10-50
if access can be provided. A hallway connected to other
upper-level living areas typically provides access. The
use of bonus rooms is determined by the home owner.
GARAGE
5/8" TYPE 'X' GYP. BD.
WALL & CEIL.
W.H.
DRY
L.S.
30" HIGH
COUNTER W/
KNEE SPACE
UTILITY
WASH
BRM
IR
Homes with a high-pitched roof often have space above
the main living area or above the garage that can be
converted from attic space into extra living space if the
S.P.
F.A.U
O
N
BD
LT
W
D
DW
G.D.
SEWING
CENTER
FIGURE 1048 Common utility room appliances.
FOLD-DN
IRON BD.
KITCHEN
3 SHELVES
REFR
SK
5 SHELVES
.
DBL
T.C. OVEN
PAN
FIGURE 1049B This utility room provides a service entry,
spacious layout for laundry chores, a sewing center, and plenty
of storage.
202
FIGURE 1050 What might have been unused attic space can
often be turned into living space as a bonus room. Courtesy Leta
Allmain.
Common uses for the area include a family room,
additional sleeping areas, or a home office. When a
bonus room is used for one of these purposes, windows must be provided to meet code requirements for
light, ventilation, and emergency egress. Dormers are
usually provided to meet building code requirements.
Verify code requirements for each of these requirements as well as minimum wall heights in Chapter 9.
See Chapter 22 for a discussion of dormers.
Architectural Drafting and Design
bike to an in-house weight room or gymnasium. If an
exercise room will be provided, space for the equipment should be provided, as well as hallways and
doors that are wide enough to provide access. The
room should be near a bathroom, or it may have its
own bath in larger custom homes. Features such as a
steam room, sauna, and massage room are also located
close to the exercise room. Figure 10-51 shows a full
health center created for a custom home. An interior
lap pool such as the pool shown in Figure 10-52 is
common for many custom homes. When included,
consideration must be given to venting the hot, moist
air displaced by the pool. Consideration must also be
given to the additional structural needs associated with
the exercise equipment.
Garage or Carport
Believe it or not, some people actually park their car
in the garage. For those who do not, the garage often
becomes a storage area, a second family room, or a
place for the water heater and furnace. The minimum
space for a single car is 11' × 20' (3300 × 6000 mm).
Exercise Center
An exercise center or health center can range from a
spare bedroom that will be used to store an exercise
FIGURE 1051 A full weight room is often provided in many
custom homes. This room includes access to a bathroom through
the left door, and a sauna located to the right. Courtesy BOWA
Builders, Inc. Photo by Jim Tetro.
FIGURE 1052 A lap pool is sometimes included in exclusive
custom homes. Designing a ventilation or dehumidification
system is critical in the planning stages. Courtesy Dean Benfit.
Chapter 10: Room Relationships and Sizes
The minimum practical space for two cars should be
21' × 21' (6300 × 6300 mm). These sizes provide
enough room to open doors and to walk around the car.
Additional space should also be included for a workbench. A garage 22' × 24' (6600 × 7200 mm) provides
for parking, storage, and room to walk around. Many
custom homes include enclosed parking for three cars.
Consideration is often given for parking a boat, truck,
camper, or recreational vehicle.
Space should be planned in the garage or in a separate storage location for the lawn mower and other
yard equipment. Additional space must be provided
if a post is located near the center of the garage to
support an upper floor. It will also be helpful if a
required post can be located off center from front to
back so that it will not interfere with the opening of
car doors.
The garage location is often dictated by the site.
Although access and size are important, the garage
should be designed to blend with the residence. Many
home owners prefer that the garage doors not be seen
from the street as the home is being approached.
Clients usually have a preference for either one large
single door or smaller doors for each parking space.
A single door 8' wide × 7' high (2400 × 2100 mm)
is common. A door 9' (2700 mm) wide is the smallest
that should be used for a truck with wide-side mirrors,
or for most boat trailers.
A double door is typically 16' (4800 mm) wide.
Aside from the owner’s preference, posts required to
support upper floors may influence the type of door
to be used. Typically, the space between doors will be
based on the amount of space needed inside the garage
to allow car doors to open without hitting anything.
When multiple single doors are to be used, consideration should be given to lateral bracing for the front
of the garage. Although a good engineer can make
any structure stand up, keeping the space between
doors to a minimum and increasing the size of the
walls at each outer edge of the garage can minimize
the cost of keeping the front wall rigid. Chapter 32
will explore lateral bracing in more detail. As a general guideline, do not let structural considerations
dictate the initial design. A 32" (800 mm) wide door
should be installed to provide access from the garage
to the yard.
In areas where cars do not need to be protected
from the weather, a carport can be an inexpensive
alternative to a garage. Provide lockable storage
space on one side of the carport if possible. This
can usually be provided between the supports at the
exterior end.
203
TRAFFIC PATTERNS
A well-designed home must consider the relationship
of the rooms to each other, the flow from the interior to
the exterior, and the rooms’ relationship to the site and
orientation of the sun.
Interior Traffic
A key aspect of any design is the traffic flow between
areas of the residence. Traffic flow is the route that
people follow as they move from one area to another.
Often this means hallways, but areas of a room are also
used to aid circulation. Rooms should be of sufficient
size to allow circulation through the room without
disturbing the use of the room. By careful arrangements
of doors, traffic can flow around furniture rather than
through conversation or work areas.
Interior Hallways
Codes that cover the width of hallways were covered
in Chapter 9. Good design practice will provide a
width of 36" to 48" (900 to 1200 mm) for circulation
pathways. A space of 48" (1200 mm) is appropriate
for pathways that are used frequently, such as those
that connect main living areas. Pathways used less
frequently can be smaller. In addition to hallways,
the entries of a residence are important in controlling
traffic flow.
Traffic between Floor Levels
In addition to considering traffic flow between rooms, it
is important to determine how the levels of a home will
relate to each other. The ideal location for stairs is off a
central hallway. Many floor plans locate the stairs in or
near the main entry similar to Figure 10-53 to provide
an attractive focal point in the entry, as well as convenient access to upper areas. Stairs should be located for
convenient flow from each floor level and should not
require access through another room. The location will
also be influenced by how often the stairs will be used.
Stairs serving mechanical equipment in a basement will
be used less frequently than stairs connecting the family
room to other living areas.
Traffic Flow between Interior
and Exterior Areas
Just as important as how the major interior areas relate
to each other is the traffic flow between each of these
areas and exterior areas. A well-planned home will
expand the inside living areas to outside areas such
204
Architectural Drafting and Design
FIGURE 1054 A sunroom is a multipurpose room that can
be used as a reading room, a breakfast room, or a music
room, or as extra space for entertaining while providing
transition between interior and exterior spaces. Courtesy Marvin
Windows and Doors.
FIGURE 1053 Many floor plan designs locate the stairs in or
near the main entry to serve as a focal point in the foyer. Courtesy
Dick Carroll.
as courtyards, patios, decks, balconies, and porches.
Sunrooms and solariums are interior areas that combine
interior and exterior features. Exterior structures that
enhance outdoor living include gazebos and arbors.
Each should be planned so that it blends with the overall design of the home.
A sunroom or solarium is a common way to bring
the outside into the interior living areas. A sunroom
is a multipurpose room, similar to the one shown in
Figure 10-54 that can be used as a reading room, a breakfast room, a music room, or as extra space for entertaining while providing transition between the interior and
exterior spaces. A solarium is typically associated with
passive solar heating, but the room also provides an
excellent location for casual living and may include a lap
pool, a spa, or an area for indoor gardening. Each of these
uses will require that ventilation, sun orientation, and
views are carefully planned. Chapter 12 will introduce
materials to help in planning a sunroom or solarium.
Figure 10-55 shows a solarium used to provide added
room for entertainment and to enclose a spa.
Most of the terms describing exterior areas are strictly
defined and regulated by building codes, but the use of
FIGURE 1055 A solarium can provide an excellent location for
casual living and may include a lap pool, spa, or an area for indoor
gardening. Courtesy Sunbilt Solar Products.
Chapter 10: Room Relationships and Sizes
FIGURE 1056 A patio designed to provide an elegant extension of the living areas to the outside. Courtesy Eric S. Brown Design
Group, Inc. Photo by Lawrence Taylor.
205
Balconies and decks are elevated floors. The IRC
defines a deck as an exterior floor supported on at least
two opposing sides by adjoining structures, posts, or
piers. Figure 10-57 shows a covered deck supported by
columns on the upper floor of a home. A balcony is an
above-ground deck that projects from a wall or building
with no additional supports.
Although a porch is not defined by the building code,
a common perception is that it is an enclosed patio or
deck, as in Figure 10-58. In some areas of the country,
the term enclosed would refer to walls, windows, doors,
and a roofed area. In warmer areas of the country,
enclosed may include only a roof or awning-type covering to protect the area from sunlight, insects, or other
natural elements. The usefulness of an outdoor area
these terms by the general public will vary slightly. The
IRC defines a court as an exterior space that is at grade
level, is enclosed on three or more sides by walls or
a building, and is open and unobstructed to the sky.
The courtyard provides an excellent screen, allowing
privacy for outdoor living in the front yard and a secure
play area for young children. Courtyards can be used
as an extension of the living, dining, and family rooms
by providing a patio or deck and landscaped areas. A
patio is a ground-level exterior entertaining area made
of concrete, stone, brick, or treated wood. The patio in
Figure 10-56 is designed to provide an elegant extension of the living areas to the outside. It provides good
access to the interior, ample areas of sunny and shaded
seating, and room for pool activities.
FIGURE 1057 What many would consider the balcony or
veranda of this historic southern home is considered a deck by
building codes. The IRC defines a deck as an exterior floor that
is supported on at least two opposing sides by adjoining structures, posts, or piers. Courtesy Eric S. Brown Design Group, Inc. Photo by
Oscar Thomson.
FIGURE 1058 An enclosed porch can provide outdoor living
protected from insects and weather. Courtesy California Redwood
Association. Waters, Cluts, and O’Brian Architect; photo by Saari Forai.
206
may be greatly increased if it is enclosed by screens,
plastic, or glass panels. Gazebos and arbors are freestanding structures that provide protection from the
elements. Common uses include protected outdoor
eating areas, covered pools, or spas.
Most families will require one or more outdoor
entertaining areas. To determine which areas are to be
included in a home, designers must consider needs,
function, location, orientation, climate, and size. Key
questions to be considered with the client include:
●
When will the area be used?
● Who will use it?
● What activities are planned for the area?
● Will traffic flow through the area?
Areas that may need to be provided include a play
area for children; seating for dining, quiet activities, or lounging in the sun; and space for outdoor
games such as Ping-Pong, shuffleboard, and tennis.
Common to most outdoor entertainment areas of
custom homes is an outdoor kitchen similar to
Figure 10-59. A patio or deck that will be used for
outdoor eating will have different size requirements
if a pool or spa is to be included. A deck will seem
smaller than a patio of the same size because of the
addition of a rail. Any deck, patio, or balcony is
required to have a guardrail when the finished floor
height is 30" (750 mm) or more above the finish grade
or floor below. A balcony as small as 36" (900 mm)
wide can be used to place a lawn chair in a sunny
spot for one person. A minimum balcony width of
48" (1200 mm) should be provided for two or more
FIGURE 1059 Covered patios and creative landscaping can be
used to beautify outdoor living areas. Courtesy Eric S. Brown Design
Group, Inc. Photo by Oscar Thomson.
Architectural Drafting and Design
small chairs, to allow access. The minimum space for
patios and decks that will include a seating and traffic area is 10' × 14' (3000 × 4200 mm).
Once the function is determined, the location
of the deck or patio must be considered. A patio
or deck located near main living areas will need
to incorporate traffic flow in addition to the space
required for its own functions. Exterior areas located
near a bedroom or bathroom suite should have some
type of screen or landscaping to provide privacy.
Figure 10-60 shows how landscaping can be incorporated into the design to provide a sense of privacy
and beauty.
A designer must consider the orientation of the
outdoor area and the local climate. A balcony or deck
may be placed on the west side of a home in a northern region to take advantage of the sun. In a southern
region, designing for shade will be of great importance.
Just as important as the movement of the sun will be
prevailing wind directions and the view. Chapter 13
will discuss methods of designing homes to enhance
the relationship of the home to terrain, view, sun, wind,
and sound.
FIGURE 1060 Landscaping can be an effective way to enhance
outdoor living. Courtesy Sherry Benfit.
207
GOING
GREEN
Green Design Considerations
You may not have thought about it as you read this
chapter, but the design concepts presented throughout
this chapter are based on green construction and
energy efficient design. Green design is much more than
specifying appliances that are certified efficient by the
Energy Star program. A key element of green design is
the process of designing a home so that it blends with
its environment aesthetically, flows with the terrain
with minimal impact on the natural resources, and takes
advantage of prevailing winds to heat and cool the
home. Good planning involves designing each room of
the house so that it functions well with adjoining rooms.
Good environmental planning requires not only that
the home meets the design criteria of the family, but it
must also make efficient use of the movement of the sun
throughout the day and the entire year. By arranging
the required living, sleeping, and service areas of a home
based on the site and its orientation to the sun, the
efficiency of the home’s heating and cooling systems can
ADDITIONAL RESOURCES
• Placing the kitchen near the utility room to minimize
the steps required between two major work areas.
• Placing the laundry utilities near where the majority
of laundry will be created to greatly reduce travel
distances.
• Placing a kitchen window to allow for supervision of
the play area of small children.
• Designing the location of appliances so that heat
produced by the appliance can be an asset to the
living area and not be detrimental to items in
surrounding storage areas.
See CD for more information
One of the best ways to improve your ability to
design pleasing homes is to look at successful designs.
Excellent sources for review include magazines, television, and the Internet. To increase your reading options,
use your favorite search engine and research major
listings such as architectural magazines, interior design
magazines, and home magazines. Magazines used by
designers include:
Architect’s Journal
Architectural Design
Architectural Digest
Better Homes and Gardens
Building Design &
Construction
Country Home
Country Living
Design Architecture
be enhanced, and the energy used to maintain the inside
environment can be greatly reduced.
The layout of features within the home also contributes
to the efficiency of the occupants of the home. A welldesigned floor plan will minimize travel distances from
major areas of the home to enhance efficient living. Small
things such as:
Design Times
DesignLine (AIBD)
Home
Home Design
House Beautiful
In Style
Kitchen & Bath Design
News
Metropolitan Home
If you have access to cable or satellite television, channels such as HGTV and TLC provide an excellent
selection of programs that explore architectural design,
interior design, and construction. New programs are
aired each season, so be sure to check program listings
or the Web sites for your favorite station for available
programs. Current popular programs include:
24 Hour Design
Awesome Interiors
Before & After
Classic Casual Living
Curb Appeal
Decorating Cents
Decorating with Style
Designed to Sell
Designers’ Challenge
Devine Design
Dream House
House Hunters
Interiors by Design
Kitchen Designs
Pure Design
Room by Room
This Old House Classics
This Small Space
What You Get for the
Money
World’s Most Extreme
Homes
Information about each program can be obtained by contacting http://www.hgtv.com, http://www.tlc.discovery.
com, or by using a search engine to search the Internet.
Other Web sites that promote interior design include:
Address
www.aibd.org
Company, Product,
or Service
American Institute of
Building Design
208
www.arcadiandesign.net
www.aham.org
www.decoratorsecrets.com
www.about.com
www.iida.com
www.kcma.org
www.maplefloor.org
www.marble-institute.com
www.nspi.org
Architectural Drafting and Design
Arcadian Residential Design
Association of Home
Appliance Manufacturers
Decorator Secrets
Home-planning guide on the
Internet
International Interior Design
Association
Kitchen Cabinet
Manufacturers Association
Maple Flooring Manufacturers Association, Inc.
Marble Institute of America
National Spa and Pool
Institute
www.glasswebsite.com/nsa
www.wineracksamerica.com
National Sunroom
Association
Wine Cellar Design
The best way to improve your skills is to visit open
homes. Walking through a wide variety of homes and
construction sites will help you visualize the materials you will be drawing. As you walk through homes,
it may be helpful to take measurements of each room
and develop a list of sizes that you find pleasing or
confining.
Photographing homes and their decor is an additional method to help you remember fine details of
interior design. Photos of each area of a home can be
a valuable aid in your future as you help clients define
their taste.
Room Relationships and Sizes Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 10 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You
do not need to write out the question. Answers may be prepared on a word processor if course guidelines allow it.
3. Answers should be based on the code that governs your
area, unless otherwise noted.
Question 10–1 What are the three main areas of a home?
Question 10–2 How much closet area should be provided
for each bedroom?
Question 10–3 What rooms should the kitchen be near?
Why?
Question 10–4 What are the functions of a utility room?
Question 10–5 Give the standard size of a two-car garage.
Question 10–6 List five functions of a family room.
Question 10–7 What are the advantages of placing
bedrooms on an upper floor?
Question 10–8 What are the advantages of placing
bedrooms on a lower floor?
Question 10–9 List four design criteria to consider in
planning a dining room.
Question 10–10 What are the service areas of the home?
Question 10–11 List and describe two types of entries.
Question 10–12 Using the Internet, research five sources
of information about the design of a home theater.
Question 10–13 Describe the use of a foyer in a home.
Question 10–14 Describe the difference between a formal
and a casual living room.
Question 10–15 What should be considered when
determining living room placement?
Question 10–16 You are designing a home for a family
with no children. The clients insist on having only
one bedroom. How would you counsel them?
Question 10–17 Visit several open homes in your area
and take pictures or obtain floor plans of a minimum
of five different master bedroom suites.
Question 10–18 Visit several different home supply
stores or use the Internet to obtain information on
several different closet storage options.
Question 10–19 Redesign Figure 10-32 to allow access
from the entry to the dining room without passing
through the living room or kitchen.
Question 10–20 Use the Internet to visit builder
organizations such as the National Association of
Home Builders. Research current issues affecting
home building in your region.
CHAPTER 11
Exterior Design Factors
I
N
T
R
O
D
U
C
T
I
O
N
The design of a house does not stop once the room arrangements have been determined. The exterior of the residence
must also be considered. Often a client has a certain style in
mind that will dictate the layout of the floor plan. In this chapter, ideas will be presented to help you better understand the
design process. To design a residence properly, consideration
must be given to the site, the style and shape of the floor plan,
exterior styles, and the energy efficiency of the design. Site considerations will be explored in Chapter 13 and energy-efficient
design will be explored in Chapter 12.
determine what may or may not be built. Although
once found only in the most exclusive neighborhoods,
review boards are now common in undeveloped subdivisions, recreational areas, and retirement areas.
These boards often set standards for minimum square
footage, height limitations, and the type and color of
siding and roofing materials. A potential home owner
or designer is usually required to submit preliminary
designs to the review board showing floor plans and
exterior elevations.
Access
SITE CONSIDERATIONS
Several site factors affect the design of a house. Among
the most important are the neighborhood and access
to the lot. For a complete description of each item,
see Section 3.
Site access can have a major effect on the design of the
house. The narrower the lot, the more access will affect
the location of the entry and the garage. Figure 11-1
shows typical access and garage locations for a narrow
lot with access from one side. Usually only a straight
driveway is used on interior lots because of space
restrictions.
Neighborhood
In the initial planning of a residence, the neighborhood must be considered. It is extremely poor
judgment to design a $500,000 residence in a neighborhood of $150,000 houses. This is not to say that
the occupants will be unable to coexist with their
neighbors, but the house will have poor resale value
because of the lower value of the houses in the rest
of the neighborhood. The style of the houses in the
neighborhood should also be considered. Not all
houses should look alike, but some unity of design
can help preserve high values for all the properties in
the neighborhood.
Review Boards
To help keep the values of the neighborhood uniform,
many areas have architectural control committees.
These are review boards made up of residents who
FIGURE 111 Access to an inner lot is limited by the street and
garage location.
209
210
Architectural Drafting and Design
When a plan is being developed for a corner lot,
there is much more flexibility in garage and house
placement. To enhance livability, some municipalities are moving away from the layouts shown
in Figure 11-1. Traditional layout has produced what
is referred to as a snout house, meaning a home that
is dominated by a view of the garage. In a design
where the home is dominated by the garage, the
main entrance to the home is often secondary to the
entrance for cars, and the driveway often dominates
the front yard. In an attempt to eliminate barriers
between homes and enhance visibility, building covenants may call for:
●
At least one main entrance to the house that meets
one of the following requirements:
FIGURE 113 A pleasing relationship between the residence
and the garage.
❍ The main entrance can be no further than 6'–0"
(1800 mm) behind the longest wall of the house
that faces the street.
❍ The main entry must face the street, or be at an
angle of up to 45°.
●
At least 15% of the area of the street-facing facade of
the home must be windows.
●
The length of the garage wall facing the street may
not be greater than 50% of the length of the entire
facade of the home.
●
A garage wall that faces a street may be no closer to
the street property line than the longest street-facing
wall of the home (see Figure 11-2).
SMALL REAR YARD
NO PRIVACY
Figure 11-3 shows an example of a pleasing relationship between the garage and the balance of the home.
Another popular way to make a neighborhood more
livable is to remove the garage altogether from the front
of the site. Many planned areas have moved the garage
to the rear of the site so that no driveway or parking
is provided on the entry or front side of the home.
Automobile access is provided to the rear of the lot by
an alley.
When a residence is being planned for a rural site,
weather and terrain can affect access. Studying weather
patterns at the site will help reveal areas of the lot that
may be inaccessible during parts of the year because of
poor water drainage or drifted snow. The shape of the
land will determine where the access to the house can
be placed. Figure 11-4 shows a garage carefully blended
into a home on a large site.
ENLARGED
REAR YARD
IMPROVED
PRIVACY
POOR
VISIBILITY
IMPROVED
VISIBILITY
FIGURE 112 By limiting the distance that the garage can project from the balance of the home, visibility is improved, which
promotes a friendlier neighborhood atmosphere.
FIGURE 114 On larger sites, the entrance to the garage can
often be moved away from the main entry. Courtesy David Jefferis.
Chapter 11: Exterior Design Factors
211
FIGURE 116 Horizontal lines can be used to accent the
length, or hide the height, of a structure. Courtesy Western Red
Cedar Lumber Association.
FIGURE 115 Curved lines are used to provide smooth
transitions and accent a structure. Courtesy California Redwood
Association.
ELEMENTS OF DESIGN
The elements of design are the tools the designer uses
to create a structure that will be both functional and
pleasing to the eye. These tools are line, form, color,
and texture.
Horizontal surfaces often create a sense of relaxation
and peacefulness. Vertical lines create an illusion of
height; they lead the eye upward and tend to provide
a sense of strength and stability. Vertical lines are
often used in columns, windows, trim, and siding
patterns similar to the home in Figure 11-7. Diagonal
lines can often be used to create a sense of transition.
Diagonal lines are typically used in rooflines and
siding patterns.
Form
Lines are used to produce forms or shapes. Rectangles,
squares, circles, ovals, and ellipses are the most
common shapes found in structures. These shapes
are typically three-dimensional, and the proportions
between them are important to design. For the best
results, the form of a structure should be dictated
by its function. Forms are typically used to accent
Line
Line provides a sense of direction or movement in the
design of a structure and helps relate it to the site and
the natural surroundings. Lines may be curved, horizontal, vertical, or diagonal and can accent or disguise
features of a structure. Curved lines in a design tend to
provide a soft, graceful feeling. Curves are often used
in decorative arches, curved walls, and round windows and doorways. Figure 11-5 shows how curved
surfaces can be used to accent a structure.
Horizontal lines are typically seen in long roof or
floor shapes, window layout, siding trim, balconies,
and siding patterns. Horizontal features in a structure can be used to minimize the height and maximize the width of a home, as seen in Figure 11-6.
FIGURE 117 Vertical lines can be used to accent the height of
a structure. Courtesy Louisiana-Pacific Corporation.
212
Architectural Drafting and Design
FIGURE 118 Forms such as rectangles, circles, and ovals are
used to provide interest. Courtesy Louisiana-Pacific Corporation.
specific features of a structure. Figure 11-8 shows
how form can be used to break up the length of a
residence. Form is also used to create a sense of security. For example, large columns provide a greater
sense of stability than thinner columns.
Color
Color is an integral part of interior design and decorating and helps distinguish exterior materials and accent
shapes. A pleasing blend of colors creates a dramatic
difference in the final appearance of any structure.
Color is described by the terms hue, value, and intensity.
Hue represents what you typically think of as the
color. Colors are categorized as primary, secondary, or
tertiary on a color wheel similar to Figure 11-9. Primary
colors—red, yellow, and blue—cannot be created from
any other color. All other colors are made by mixing,
darkening, or lightening primary colors. Secondary
colors—orange, green, and violet—are made from an
equal combination of two primary colors. Mixing a
primary color with a secondary color will produce a
tertiary or intermediate color—for example, red-orange,
yellow-orange, yellow-green, blue-green, blue-violet,
and red-violet. Mixing each of the primary colors in
equal amounts will produce black.
Mixing black with a color will darken the color,
producing a shade of the original color. White has no
color pigment and gray is a mixture of black and white.
Adding white to a color lightens the original color,
producing a tint. Value is the darkening or lightening
of a hue.
Intensity is the brightness or strength of a specific
color. A color is brightened as its purity is increased by
removing neutralizing factors. Sports cars often have
high-intensity colors. A color is softened by adding the
color that is directly opposite it on the color wheel.
Low-intensity colors such as mint green are used to
create a calming effect.
Colors are also classified as warm or cool. Colors
seen in warm objects, such as the reds and oranges of
burning coals, are warm colors. Warm colors tend to
make objects appear larger or closer than they really are.
Blues, greens, and violet are cool colors. These colors
often make objects appear farther away. Most designers
use neutral colors for the major portions of a home and
rely on the trim and roofing for accent colors. Color
can be added through landscaping and interior design
features.
Texture
WA
RM
TERTIARY
RED-VIOLET
PRIMARY
RED
TERTIARY
RED-ORANGE
SECONDARY
VIOLET
SECONDARY
ORANGE
TERTIARY
BLUE-VIOLET
TERTIARY
YELLOW-ORANGE
PRIMARY
BLUE
PRIMARY
YELLOW
TERTIARY
BLUE-GREEN
CO
SECONDARY
GREEN
TERTIARY
YELLOW-GREEN
OL
FIGURE 119 The color wheel shows primary, secondary, and
tertiary colors. These categories are then divided into warm and
cool colors.
Texture, which refers to the roughness or smoothness
of an object, is an important factor in selecting materials
to complete a structure. Rough surfaces tend to create a
feeling of strength and security—examples include concrete masonry and rough-sawn wood. Rough surfaces
also give an illusion of reduced height. Resawn wood,
plastic, glass, and most metals have a very smooth
surface and create a sense of luxury. A smooth surface
tends to give an illusion of increased height; also, it
reflects more light and makes colors seem brighter.
PRINCIPLES OF DESIGN
Line, form, color, and texture are the tools of design.
The principles of design affect how these tools are used
to create an aesthetically pleasing structure. The basic
principles to be considered are rhythm, balance, proportion, and unity.
Chapter 11: Exterior Design Factors
FIGURE 1110 Repetitive features lead the eye from form to
form. Courtesy Monier.
213
FIGURE 1111 Formal balance places features evenly along an
imaginary center line. Courtesy Aaron Jefferis.
Rhythm
Most people can usually recognize rhythm in music.
The beat of a drum is a repetitive element that sets the
foot tapping. In design, a repetitive element provides
rhythm and leads the eye through the design from one
place to another in an orderly fashion. Rhythm can also
be created by a gradual change in materials, shape, and
color. Gradation in materials could be from rough to
smooth, gradation in shape from large to small, and
gradation in color from dark to light. Rhythm can also
be created with a pattern that appears to radiate outward
from a central point. A consistent pattern of shapes,
sizes, or material can create a house that is pleasing to
the eye as well as provide a sense of ease for the inhabitants and convey a sense of equilibrium. Figure 11-10
shows elements of rhythm in a structure.
FIGURE 1112 Informal balance is achieved by moving the
center line away from the mathematical center of a structure
and altering the sizes and shapes of objects on each side of
the center line.
Balance
Balance is the relationship between the various areas of
the structure and an imaginary center line. Balance may
be formal or informal. Formal balance is symmetrical;
one side of the structure matches the opposite side
in size. The residence in Figure 11-11 is an example
of formal balance. Its two sides are similar in mass.
Informal balance is asymmetrical; in this case, balance
can be achieved by placing shapes of different sizes in
various positions around the imaginary center line. This
type of balance can be seen in Figure 11-12.
Proportion
Proportion is related to both size and balance. It can be
thought of in terms of size, as in Figure 11-13, where
one exterior area is compared with another. Many
FIGURE 1113 Shapes that are related by size and shape
create a pleasing flow from form to form. Courtesy Saundra Powell.
214
current design standards are based on the designs of
the ancient Greeks. Rectangles using the proportions
2:3, 3:5, and 5:8 are generally considered very pleasing. Proportion can also be thought of in terms of
how a residence relates to its environment.
Proportions must also be considered inside the
house. A house with a large living and family area
needs to have the rest of the structure in proportion.
In large rooms the height must also be considered.
A 24' × 34' (7200 × 10 200 mm) family room is too
large to have flat ceiling 8' high. This standard-height
ceiling would be out of proportion to the room size.
A ceiling 10' high, or a vaulted ceiling, would be
much more in keeping with the size of the room.
Unity
Unity relates to rhythm, balance, and proportion.
Unity ties a structure together with a common design
or decorating pattern. Similar features that relate
to each other can give a sense of well-being. Avoid
adding features to a building that appear to just be
there or tacked on (see Figure 11-14).
As an architectural drafter, you should be looking
for these basic elements in residences that you see.
Walk through houses at every opportunity to see
how other designers have used these design basics.
Many magazines are available that feature interior and
exterior home designs. Study the photos for pleasing
relationships and develop a scrapbook of styles and
layouts that are pleasing to you. This will provide valuable resource material as you advance in your drafting
career and become a designer or architect.
Architectural Drafting and Design
FIGURE 1115 A single-level residence is popular because
it allows stair-free access to each area. Courtesy Pamela Russom,
American PolySteel.
FLOOR PLAN STYLES
Many clients come to a designer with specific ideas
about the kind and number of levels they want in a
house. Some clients want a home with only one level
so that no stairs will be required. For other clients, the
levels in the house are best determined by the topography of the lot. Common floor plan layouts are singlelevel, split-level, daylight basement, two-story, dormer,
and multilevel.
Single-Level
The single-level house (Figure 11-15) has become one
of the most common styles. It is a standard of many
builders because it provides stair-free access to all
rooms, which makes it attractive to people with limited
mobility. It is also preferred by many home owners
because it is easy to maintain and can be used with a
variety of exterior styles.
Split-Level
FIGURE 1114 Unity is a blend of varied shapes and sizes
to create a pleasing appearance. Courtesy California Redwood
Association. Waters, Cluts, and O’Brian Architects; photo by
Saari Forai.
The split-level plan (Figure 11-16) is an attempt to
combine the features of a one- and a two-story residence. This style is best suited to sloping sites, which
allow one area of the house to be two stories and
another area to be one story. Many clients like the
reduced number of steps from one level to another
that is found in the split-level design. The cost of construction is usually greater for a split-level plan than
for a single-level structure of the same size because
of the increased foundation cost that the sloping lot
will require.
Chapter 11: Exterior Design Factors
FIGURE 1116 Homes with split floor levels are ideal for gently
sloping sites. Courtesy LeRoy Cook.
Split-level plans may be split from side to side or
front to back. In side-to-side split-levels, the front
entrance and the main living areas are typically located
on one level, with the sleeping area located over the
garage and service areas. In front-to-rear splits, the
front of the residence is typically level with the street,
with the rear portion stepping to match the contour of
the building site.
Daylight Basement
The style of house called daylight basement could be
either a one-story house over a basement or garage, or
two complete living levels. This style of house is well
suited for a sloping lot. From the high side of the lot,
the house will appear to be a one-level structure. From
the low side of the lot, both levels of the structure can
be seen (see Figure 11-17).
FIGURE 1117 A home with a daylight basement allows living
areas on the lower level to have access to the exterior on one or
more sides of the home, while looking like a one-level home on
the opposite side. Courtesy Janice Jefferis.
215
FIGURE 1118 Two-level homes provide the maximum square
footage of living area using the minimum amount of the lot.
Two-Story
A two-story house (Figure 11-18) provides many
options for families that do not mind stairs. Living and
sleeping areas can be easily separated, and a minimum of
land will be used for the building site. On a sloping lot,
depending on the access, the living area can be on either
the upper or lower level. The most popular feature of a
two-level layout is that it provides the maximum building area at a lower cost per square foot than other styles
of houses. This saving results because less material is
used on the foundation, exterior walls, and roof.
Dormer
The dormer style allows an upper level that is usually
about half of the square footage of the lower floor.
This use of dormers is best suited to an exterior style
that incorporates a steep roof similar to Figure 11-19.
These small dormers, often called doghouse dormers,
FIGURE 1119 Dormer-style home. Courtesy Matthew Jefferis.
216
FIGURE 1120 Multilevel homes provide endless possibilities
for floor-level arrangements on sloping sites.
allow space for windows into the living space in the
attic. Another common type of dormer is a full dormer
that allows a room with full headroom to be added to
the edge of the attic space. The dormer level is formed
in what would have been the attic area. The dormer
has many of the same economic features as a two-story
home. Chapter 22 will explore other types of dormers
as roof construction is explored.
Multilevel
With a multilevel layout, the possibilities for floor levels
are endless. Site topography as much as the owners’
living habits will dictate this style. Figure 11-20 shows a
multilevel layout. The cost for this type of home exceeds
all other styles because of the problems of excavation,
foundation construction, and roof intersections.
EXTERIOR STYLES
Exterior style is often based on past styles of houses.
New homes usually do not try to replicate the exact
layout of past styles of homes, but they typically do try
to copy the exterior style and charm associated with a
specific historic style. The balance of this chapter will
examine home styles that were common to the original
settlers. Styles will be explored based on the time period
of their popularity and the area of the world where the
style originated.
Colonial
The early colonists lived in log cabins. Many companies now sell plans and precut kits for assembling
log houses. Many of the colonial houses were similar
Architectural Drafting and Design
FIGURE 1121 Dating back to historical New England, colonial
homes are very symmetrical, with windows equally spaced on
both sides of the main entry. Courtesy Michael Jefferis.
in style to the houses that had been left behind in
Europe. Construction methods and materials were
varied because of the weather and building materials available.
Many colonial home styles date back to historical
New England. A colonial home can be described as a
home where the second-floor living area is the same
size as the first-floor living area. More specifically, it
was symmetrically designed with a center door with
windows equally spaced on both sides and a gable
roof with the ridge that runs parallel to the front
side of the home. Bedrooms were usually on the
second floor. Newer versions of the colonial style
often have a covered front porch, attached garage,
and a family room situated behind the garage. The
second-floor living area frequently extends over the
garage. Figure 11-21 shows an example of a home
built using the colonial style.
Colonial influence can still be seen in houses that
are built to resemble the Georgian, saltbox, garrison,
Cape Cod, Federal, Greek revival, and southern colonial
styles of houses. House styles from the colonial period
also include influences of the English, Dutch, French,
and Spanish. Other popular styles include farmhouse,
ranch, Victorian, and contemporary.
Georgian
The Georgian style is an example of a basic style that
was modified throughout the colonies in response to
available materials and weather. The style was named
for the kings of England who were in power when it
flourished in the eighteenth and nineteenth centuries.
The Georgian style followed the classical principles
of design used by ancient Romans. This English style
Chapter 11: Exterior Design Factors
217
FIGURE 1123 Georgian-style homes have formal balance,
with the entry on the center line. Courtesy Jordan Jefferis.
Saltbox
FIGURE 1122 Dentil molding is a tooth-like trim that is often
placed along the eaves of homes trying to replicate traditional
styling. A Palladian window, a large window that is divided into
three parts, is also a common feature of Georgian- and Federalstyle homes.
came to America by way of British pattern books and
from the masons, carpenters, and joiners who emigrated
from England. The style became a favorite of well-to-do
colonists who wanted their homes to convey a sense of
dignity and prestige.
Georgian house plans were rectangular in shape,
usually two or three stories in height, and usually had
symmetrical floor plans. The roofs had a medium roof
pitch with small overhangs. Square tooth-like trim
called dentil molding, shown in Figure 11-22, was
often placed along the eaves. Chimneys were placed in
the sidewalls, and a central hall was typically flanked
by one or two rooms. The principles of form and symmetry were most evident in Georgian style in the front
elevation. The front entry was centered on the wall,
and equally spaced double-hung windows with 9 or
12 windowpanes were usually placed on each side of
the door. A transom window was usually placed above
the door. The front entry was usually covered with a
columned porch supported by pilasters or columns,
and the doorway was trimmed with carved wood
detailing. Windows and doors were usually surrounded by decorative framework.
Georgian homes almost always featured a row of
five windows on the front facade just below the eave
on the second story. In the South, much of the facade
was built of brick. In northern states, wood siding
was the major covering. Other common exterior
materials used were stucco and stone. An example of
a home built following the Georgian style can be seen
in Figure 11-23.
One of the most common modifications of the Georgian
style is the saltbox. The saltbox maintained the symmetry of the Georgian style but omitted much of the
detailing. This housing style received its name because
its steep roof resembled colonial-era salt containers. A
saltbox was typically a two-story structure at the front
but tapered to one story at the rear. In Colonial times,
the lower rear portion was often used as a partially
enclosed shed, which was oriented north as a windbreak. These square or rectangular homes typically had
a large central chimney and large, double-hung windows that had shutters to provide protection from
winter winds. Exterior walls were covered with clapboard or shingles. Figure 11-24 shows a home that
incorporates features of saltbox styling.
Garrison
The garrison style combined saltbox and Georgian
style with the construction methods of log buildings.
Originally modeled after the lookout structures of early
FIGURE 1124 A saltbox residence has a two-level front and
a one-level rear.
218
Architectural Drafting and Design
FIGURE 1125 A garrison-style home has an upper level that
extends over the lower level. Courtesy Matthew Jefferis.
FIGURE 1126 A Cape Cod home features the formal balance
of other styles but adds dormers and shutters. Courtesy GeorgiaPacific Wood Products LLC.
forts, the upper level of a garrison-style home extended
past the lower level. Originally, heavy timbers were
used to support the overhang and were usually carved.
Garrison-style homes were typically sided in unpainted
clapboard or wood shingles, had steep gabled roofs, and
small diamond-paned windows. Figure 11-25 shows
the garrison-style features that have been incorporated
into a modern residence.
mid-twentieth century, the small, uncomplicated
Cape Cod shape became popular in suburban developments. A twentieth-century Cape Cod is square or
rectangular with one or one-and-a-half stories and
steeply pitched, gabled roofs. The siding is usually
clapboard or brick and dormers and window shutters are also typical of the style.
Federal
Cape Cod
Cape Cod style consisted of a one-level boxed
structure with a steep gabled roof that allowed
an upper-floor level to be formed throughout the
center of the house. This style of home was developed in New England during the seventeenth and
eighteenth centuries. Early Cape Cod homes were
shingle-sided, one-story cottages with two basic
rooms. The plan included a great room that was
used for daily living, and a second room that was
used as a bedroom. The central chimney had connecting fireplaces to warm each room. Over time,
a kitchen was added to the back of the house with
small bedrooms at the rear corners.
The steep roof originally associated with the style
allowed an upper-floor level to be formed throughout the center of the house. As the style advanced,
dormers were placed on the front side of the roof to
make the upper floor habitable. The upper floor was
expanded to include bedrooms that were covered
with either a shed-type dormer that covered the entire
front width, or with small dormers to allow window
placement. Windows on the lower floor were placed
symmetrically around the door and had shutters on
the lower level. An example of Cape Cod styling can
be seen in Figure 11-26.
An offshoot of the Cape Cod style is Cape Ann,
which has many of the same features as a Cape Cod
house but is covered by a gambrel roof. During the
The Federal style was popular in America between
1780–1840. Federal homes combined Georgian
architecture with classical Roman and Greek styles
to form a very dignified style. While Georgian homes
were square and angular, a Federal-style building
was more likely to have curved lines and decorative
flourishes such as swags, garlands, and elliptical
windows. Federal homes were built of wood or brick
with low-sloped roofs with dentil moldings below
the eaves. A common alternative to the dentil molding was a flat roof surrounded with a balustrade. A
balustrade is a row of repetitive, small posts called
balusters that support the upper railing similar to
Figure 11-27.
FIGURE 1127 A balustrade is often placed around a deck
sitting atop the roof of many Federal-style homes.
Chapter 11: Exterior Design Factors
219
FIGURE 1128 Common pediment styles found on traditional homes.
Other key features of the home style included a
high, covered entry porch or portico supported on
Greek-style columns centered over the front door. A
semicircular fanlight window was often placed above
the front door, surrounded with arched trim, and
narrow side windows usually flanked the front door.
Projected pediments similar to those in Figure 11-28
were another common feature of the main door.
Other windows on the front elevation were arranged
symmetrically around a center doorway, capped
with a projected pediment, and trimmed with shutters. A Palladian window was often used in the
center of the second story. A Palladian window
is a large window that is divided into three parts
similar to Figure 11-22. The center section is larger
than the two side sections, and is usually arched.
Circular and elliptical windows were often used to
add variety. Figure 11-29 shows an example of a
Federal-style residence.
Greek Revival
The Greek revival style became the chief residential
motif of wealthy landowners in the United States
from 1830 through the 1850s. Homes of this style
were built using classic proportions and decorations
of classical Greek architecture to copy features of the
FIGURE 1129 Federal style combines features of Georgian
and classical Roman and Greek architecture. Courtesy Megan Jefferis.
Parthenon. These homes were large, rectangular, and
very box-like with bold, simple lines. The exterior
was usually covered with clapboard siding or brick.
Roofs were usually low-sloped gables or hips with
small overhangs with cornices featuring wide trim
band comprising frieze and architrave. A two-story
portico with a low-sloped gable roof supported on
Greek columns was centered on the front of the
residence. The front door was usually topped with
a transom window, or capped by a prominent cornice similar to those in Figure 11-28 and flanked by
narrow sidelights. Figure 11-30 shows an example of
Greek revival architecture.
Southern Colonial
Several home styles emerged from the South as builders sought refuge from the heat, humidity, and weather
of the area. One of the most popular southern styles
was the Antebellum, which is Latin for “before war.”
The term refers to the elegant plantation homes built
in the American South in the 30 years or so preceding
the Civil War. Antebellum homes used features found
in the Greek revival or Federal style such as grand,
symmetrical facades with evenly spaced windows, and
FIGURE 1130 Greek revival features classic Greek proportions and ornamentation. Courtesy William E. Poole, William E. Poole
Designs, Inc.
220
FIGURE 1131 Southern colonial or plantation-style homes
reflect classic symmetry. They typically have a large covered
porch to provide protection from the sun.
boxy layouts with center entrances in the front and
rear, balconies, and Greek columns or pillars. Roofs
were usually low-sloped gables or hips, with small overhangs with cornices featuring a wide trim band with
frieze. Figure 11-31 shows an example of a southern
colonial home.
English
English-style houses are fashioned after houses that
were built in England prior to the early 1800s. Two
styles that are often copied based on their English roots
are the Tudor and English cottage.
English Tudor
The traditional Tudor home was made of masonry
or stucco and modeled after English manor homes,
but was also influenced by Dutch and Gothic styling.
There are several different styles of Tudor homes,
but the Elizabethan variation is most often copied
in twenty-first century architecture. The traditional
Tudor home featured an asymmetrical layout and
walls that were two or more stories in height. Exterior
walls were constructed of stone or brick set in intricate patterns, or heavy timber and plaster. The halftimbered exterior used exposed wood timbers to form
the structural framework and the spaces in between
were filled with brick or stucco. The roofs were typically made up of one or more steeply pitched gables.
Parapeted gable end walls that extended above the roof
and massive chimneys topped with decorative chimney pots were also common. Doors tops were often
rounded and windows were usually multipaned casement windows with diamond-shaped glass rather
than the more traditional rectangle. Half-timbered bay
Architectural Drafting and Design
FIGURE 1132 English Tudor combines half-timber with brick,
stone, and plaster. Courtesy Janice Jefferis.
window projections and projecting oriel windows
were other common window features. Figure 11-32
shows common features of English Tudor styling.
English Cottage
A subtype of the Tudor revival style is the Cotswold
Cottage. With a sloping roof and a massive chimney at
the front, the cottage-style home served as a model for
many storybook homes. Cottage homes were patterned
after the rustic cottages constructed in southwestern
England since medieval times and often featured steep,
half-hipped, thatched roofs. The exterior might have
featured half-timbering, stone, brick, and shingle or
stucco siding. Other common features included an
uneven gable roof; asymmetrical shape; a prominent
chimney made of brick or stone; small dormer windows; and casement windows of leaded glass.
Dutch
As early as the seventeenth century, Dutch settlers in
New York, New Jersey, and Pennsylvania were building brick and stone homes with roofs that reflected
their Flemish culture. The Dutch colonial style had
many of the features of homes already described.
The major difference was a broad two-level roof with
flared eaves that were slightly rounded into barn-like
gambrel shapes. The lower roof level was usually very
steep and served as the walls for the second floor of
the structure. The upper area of the roof was the more
traditional gable roof. Early homes were a single room,
but as the style developed, additions were made to
each end, creating a distinctive linear floor plan. End
walls were originally constructed of stone, and the
chimney was usually located on one or both ends of
Chapter 11: Exterior Design Factors
FIGURE 1133 Dutch colonial homes often feature a gambrel
roof. Courtesy Laine M. Jones Designs.
the home. Double-hung sash windows with outward
swinging wood casements, dormers with shed-like
overhangs, and a central Dutch double doorway were
also common. The double door, which was divided
horizontally, was once used to keep livestock out of
the home while allowing light and air to filter through
the open top. An example of Dutch colonial style can
be seen in Figure 11-33.
French Colonial Homes
Colonial French influence can be seen in several
common home styles found throughout the United
States. These styles include French Provincial, French
Normandy, French plantation, French mansard, and
Second Empire. Second Empire homes will be explored
later in this chapter as Victorian homes are examined.
221
FIGURE 1134 French Provincial homes featured two-level
brick or stucco structures with steep, hipped roofs and a square
balcony and porch balustrades. Second-story windows usually
had arched tops that often extended through the cornice to
rise above the eaves.
French Normandy
French Normandy homes are patterned after the homes
in Normandy and the Loire Valley of France. Many of
the original French homes had farm silos that were
attached to the home. American colonial designers used
the shape and style of the traditional French farmhouse
and created a turret with living space where the silo
would traditionally be. These homes had many of the
features of a Tudor style such as decorative half timbering with stone, stucco, or brick used between the
timbers. French Normandy homes were distinguished
from Tudor homes by a round stone tower topped by
a cone-shaped roof. The tower was usually placed near
the center, to serve as the entrance to the home. French
Normandy and French Provincial details are often combined to create a style simply called French Country or
French Rural. Figure 11-35 shows a home with French
Normandy features.
French Provincial
French Provincial colonial homes had their origins in
the style of the rural manor homes, or chateaus, built
by French nobles during the mid-1600s. Homes patterned in this style are recognized by their balance and
symmetry, which were used to create a stately, formal
home. The homes were two-level brick or stucco
structures with detailing in copper or slate. They generally had steep, hipped roofs and a square balcony
and porch balustrades. Windows and chimneys were
usually balanced on each side of the entrance. Other
defining features included rectangular doors set in
arched openings, and double French windows with
shutters. Second-story windows usually had an arched
top that extended through the cornice to rise above
the eaves. Figure 11-34 shows a home with French
Provincial features.
FIGURE 1135 French Normandy had a round stone tower
topped by a cone-shaped roof. The tower was usually placed near
the center of the home to serve as the entrance to the home.
222
Architectural Drafting and Design
FIGURE 1137 French colonial homes often hide the upper
floor behind a mansard roof. Courtesy David Jefferis.
FIGURE 1136 The French Normandy style evolved into the
French plantation style in many southern states, incorporating
two full floors and a wraparound porch covered with a hip roof.
Courtesy William E. Poole, William E. Poole Designs, Inc.
French Plantation
In the southern states, the French Normandy style
evolved into the French plantation style. This home
style incorporated two full floors and a wraparound
porch covered with a hip roof. The porch was an
important passageway because traditional French
Colonial homes did not have interior halls. A third
floor was a common component, with dormers added
for light and ventilation. Figure 11-36 shows a French
plantation home. This style was modified around New
Orleans into what is now known as the Louisiana
French style. The balcony sizes are diminished, but the
supporting columns and rails have become fancier.
these homes particularly suited for warmer climates.
Some Spanish colonial homes featured a Montereystyle, second-story porch. Arches and tiled roofs
were two of the most common features of Spanish- or
mission-style architecture. Timbers were often used
to frame a flat or very low-pitched roof. Windows
with grills or spindles and balconies supported on
square pillars with wrought-iron railings were also
common features. Round or quatrefoil windows were
often used for accent. A quatrefoil window is a round
window composed of four equal lobes that resemble
a four-leafed clover. Figure 11-38 shows an example
of Spanish-style architecture.
Italianate and Italian Villas
Two common Italian home styles that are still popular
in American architecture include the Italianate and the
Italian villas.
Italianate
French Mansard
French mansard styling used a hipped or mansard roof
to hide the upper floor area. A mansard roof is an angled
wall and will be discussed in Section 6. Originally found
in the northern states, these homes were usually a rectangle with a smaller wing on each side. The mansard
roof was used to hide the upper floor, but hip roofs were
also used. Figure 11-37 shows an example of French
mansard styling.
Italianate-style homes were a popular housing style
in the United States during the period of 1840–1885.
Spanish
In Florida, California, and the southwestern United
States, settlers drew upon Hispanic and Moorish building traditions. Spanish colonial buildings were constructed of adobe or plaster and were usually one
story. Deeply shaded porches and dark interiors made
FIGURE 1138 Spanish-style homes typically were constructed
of adobe or plaster and featured low-sloping tile roofs, arches,
and window grills. Courtesy Megan Jefferis.
Chapter 11: Exterior Design Factors
FIGURE 1139 Italianate-style homes were typically large
symmetrical rectangular structures covered with a low-pitched
roof with wide eaves. Tall, narrow, windows placed in pairs
below Roman arches were also common.
223
FIGURE 1140 Homes designed to copy the Italian villa style
typically include a rambling, asymmetrical floor layout, and
low-pitched tile roofs with large overhangs. Villa homes usually
have exteriors covered with stucco, and arched windows and
doors crowned with heavy trim.
and doors crowned with heavy trim. Figure 11-40
shows an example of an Italian villa.
This style was common throughout most of the
country because the wide variety of materials associated with the style made it adaptable to varied
budgets. Key features of this symmetrical style were
the large rectangular wood-framed structure that
emphasized vertical proportions and elaborate decorations. Structures usually ranged in height from two
to four stories and were covered with a low-pitched
roof with wide eaves featuring decorative brackets,
large cornices, and a square cupola. A single-story
arcade porch was centered on the front to cover heavily molded double entry doors. The porch was often
topped with balustraded balconies and flanked with
side bay windows. The front entry door was usually
double rectangular or arched entry doors with elaborate surrounds. Tall, narrow, double-paned windows
with hood moldings were often used with windows,
although Roman or segmented arches above windows and doors were also common. Windows were
usually placed in pairs. Figure 11-39 shows a home
using Italianate features.
Italian Villa
The Italian villa style remains popular in the United
States and is a style often used for many large custom
homes. The style became popular in America during
the nineteenth century and is recognized by its rambling, asymmetrical floor layout, low-pitched tile
roofs, and a tower. Large overhangs, supported on
decorative brackets under the eaves were also typical of
villa-style homes. Exteriors were usually covered
with stucco. Villa homes usually had arched windows
Victorian
Italianate-style homes gave way to the Victorian styles
in the late 1800s. Victorian-style homes are still being
copied in many parts of the country. These styles featured irregularly shaped floor plans and very ornate
detailing throughout the residence. Victorian houses
often borrowed elements from many other styles of
architecture, including partial mansard roofs, arched
windows, and towers. Exterior materials included a
combination of wood and brick. Wrought iron was
often used. Victorian-style homes can be divided into
Gothic, Second Empire, Folk, and Queen Anne.
Gothic Victorian
In the 1800s, fashionable houses in England began
to resemble medieval Gothic cathedrals, convents,
and storybook castles. The style moved to America
in the period from 1840–1880. The exterior walls of
these homes were typically constructed from stone or
brick with an asymmetrical floor plan. Exterior walls
were often topped to resemble a battlement of a castle
or fort, and used to surround steeply pitched roofs.
Several types of windows could be found in Gothic
architecture including pointed windows with decorative leaded glass, oriel, and quatrefoil-shaped windows.
An oriel window projects from the wall and forms
a small turret that does not extend to the ground.
Brackets or corbels usually supported the curved
walls that held the windows. Figure 11-41 shows an
example of a Gothic Victorian home.
224
Architectural Drafting and Design
FIGURE 1141 Homes from the Gothic Victorian style often
had walls that were topped to resemble a battlement of a
castle or fort, and used to surround steeply pitched roofs.
Victorian houses often borrowed elements from many other
styles of architecture, including very ornate detailing, wrought
iron fretwork, arched windows, and towers.
Second Empire
Second Empire homes were inspired by the architecture in Paris during the reign of Napoleon III, and
reached the height of their popularity in the United
States between 1855–1885. This Victorian style shown
in Figure 11-42 is easily recognizable because of its
high mansard roofs that cover the upper floors. The
roofs were often covered with patterned slate shingles. Although these homes are often seen in horror
movies, they were thought to be very elegant when
they were constructed. Walls were often covered with
ornate wood trim or intricate brick patterns. Wrought
iron crestings were also common above the upper
cornice. Other common features of this style of home
included dormer windows that projected from the
roof, classical pediments above each opening, and tall
double-hung windows on the first floor. Decorative
brackets were used for support beneath protrusions
such as eaves, window bays, and balconies.
Folk Victorian
Folk Victorian homes developed for less affluent
consumers during the period from 1870–1910.
These homes were much simpler than the traditional
Victorian homes but featured trim work made possible by mass production. Homes were traditionally
square or symmetrical with porches with spindle
work that wrapped the home. They are similar to
FIGURE 1142 Second Empire Victorian homes often included
high mansard roofs finished with patterned slate shingles,
which were used to cover the upper floors. Other common
features of this style included wrought iron crestings above the
upper cornice, dormer windows that projected from the roof,
classical pediments above each opening, and tall double-hung
windows on the first floor.
Queen Anne homes of the same time period but do
not have towers, bay windows, or elaborate moldings of that style.
Queen Anne
This style of home was popular during the period of
1880–1910 as the machine age was sweeping America.
As a result of mass production in factories, precut
architectural components were available for shipping across the country. The style was named after
the eighteenth-century English queen, and was characterized by elaborate bric-a-brac, a complicated roofline, and expansive porches that wrapped around
the front and side of the house. These homes usually had a round tower, turret, or a large round bay
window. Elaborate moldings and trim called gingerbread were also key features of the Queen Anne style.
Figure 11-43 shows an example of a Queen Anne
Victorian-style home.
Chapter 11: Exterior Design Factors
225
the classical architecture of ancient Greece and Rome,
which contain some but not all of the main features. Art
Deco structures are a style of architecture originating in
the 1920s that featured geometric, streamlined shapes
and the use of materials such as aluminum, stainless
steel, lacquer, and in-laid wood.
Farmhouse
FIGURE 1143 Queen Anne Victorian-style homes were characterized by a round tower, elaborate moldings, and gingerbread trim, a complicated roofline, and expansive porches that
wrap around the front and side of the house.
The farmhouse style made use of two-story construction
and was usually surrounded by a covered, wraparound
porch. The roof ridge ran parallel to the front surface.
A steep roof with dormers usually covered the home
with a shallow pitch at the porch. The exterior material
was usually clapboard siding. Trim and detail work,
common in many other styles of architecture, were
rarely found in farmhouse style. Figure 11-44 shows an
example of this style.
American Foursquare
Prairie
The American Foursquare home style was originally
popular during the period of 1895–1930. This style is
recognizable because of the simplicity of the design.
The style featured a simple box shape that was two
stories tall with an attic and a full basement. Each floor
generally had four rooms. The first floor contained an
entry foyer, living room, dining room, and kitchen.
The second floor was made up of three bedrooms and
a bathroom.
Walls were usually made of wood, but brick, stone,
and stucco siding with clapboards, cedar shingles, or
a combination of these materials was common. The
homes were usually covered with a low-sloped hip roof.
Large overhangs supported with cornice-line brackets or other details drawn from craftsman and Italian
Renaissance styles were a common feature. Others
features sometimes associated with a Foursquare home
were a large central dormer, and a front porch that covered the majority of the front facade of the home.
Surface features and limited decoration help this
style to adapt to a wide range of architectural styles.
A Foursquare house with white clapboard siding and
black shutters is usually identified as a Colonial Revival.
The style took on Queen Anne styling by adding bay
windows and decorative brackets. The style was later
altered again by adding stucco siding and a porch with
stone columns to resemble a craftsman bungalow.
Depending on the details that are added, the traditional Foursquare home may resemble Spanish Eclectic,
French Provincial, Tudor Neoclassical, or Art Deco.
Neoclassical is used to describe buildings inspired by
Prairie-style houses, popular in the Midwest between
1900–1920, are recognizable for their low horizontal
lines, one-story projections, low-pitched hipped roofs,
and large overhanging eaves that were designed to
help the home blend into the landscape. Roofs were
typically tile or shingles depending on the area of the
country where the home was built. Made popular by
Frank Lloyd Wright, the floor plan of a prairie home
usually consisted of open interior spaces divided by
FIGURE 1144 Farmhouse style is used to describe a simple
single-level structure with a steep roof. Dormers were usually
used to provide light to an upper loft. The roof ridge was parallel to the front of the home and a roof with a shallow pitch was
used to cover a front porch. Trim and detail work, common
in many other styles of architecture, were rarely found in the
farmhouse style. Courtesy Cardinal Homes.
226
FIGURE 1145 Prairie-style houses are recognizable for their
low horizontal lines, one-story projections, low-pitched hipped
roofs, and large overhanging eaves that were designed to help
the home blend into the landscape.
leaded or stained glass panels or built-in furniture
with natural finishes that were intended to blur the
distinction between indoors and outside. Rooms were
arranged in square, L-shaped, T-shaped, or Y-shaped
floor plans. Exterior walls varied between stuccoed
masonry, or wood-frame construction covered with
brick and beveled horizontal siding. Windows were
typically arranged in rows of small casement windows
framed in horizontal bands that accent the horizontal
lines. This style of home can now be found throughout the country (see Figure 11-45).
Bungalow
The bungalow style originated in India and became a
popular American style between 1900–1920. Originally
patterned after one-story, thatch-roofed houses in the
province of Bengal, the style was converted to a oneand-a-half story home in America. The Amercian
bungalow featured open, balanced but asymmetrical
floor plans. Roofs were usually steep enough to hide
the upper floor, or used low-sloping gables with front
and rear dormers. Large extended eaves with decorative, bracketed supports were also typical. A large
veranda covered by an extension of the main roof was
a common feature on the front of the homes. Common
exterior materials included shingles, lap siding or
board, and batten siding. Windows were typically casement or double-hung with small-paned glass, trimmed
with wide simple casings. The front door typically was
glass-paned with double sidelights.
Bungalow homes typically made extensive use of
built-in furniture, shelves, seating, and wood trim
throughout the house. The dining rooms, bedrooms,
kitchens, and bathrooms were arranged around a
central living room on the main floor. Additional
bedrooms were placed upstairs in the center of the
Architectural Drafting and Design
FIGURE 1146 The bungalow style featured simple box-like
structures with steep roofs that were used to hide an upper floor.
Low sloping gables with front and rear dormers were a common
alternative. A large veranda covered by an extension of the main
roof was a common feature on the front of these homes.
gable roof. Figure 11-46 shows a home built with
bungalow features.
Craftsman
In the early twentieth century, the craftsman-style
home became popular in America. Floor plans usually
consisted of asymmetrical, free-flowing, two-story layouts. The upper level often cantilevered over the lower
level. Lower levels were usually made of stone or brick,
and upper levels were covered in shingles, stucco,
stone, or brick. Windows were typically double-hung
with grids in the upper half and were asymmetrically
placed, or casement windows were placed in series.
Window trim was usually plain, wide-board casings.
Rectangular cantilevered bays with multiple windows
were also common.
FIGURE 1147 Craftsman-style homes featured asymmetrical,
free-flowing two-story layouts with an upper level that often cantilevered over the lower level. Roofs were steep gables supported
by decorative brackets, with multiple perpendicular gables.
Chapter 11: Exterior Design Factors
227
Homes featured a large wraparound porch that was
elevated several feet above the surrounding grade.
Porch roofs were often supported by masonry or
large decorative wood columns with wood-framed
walls covered with shingles used as a railing between
the columns. Open large-scale balusters were also a
common alternative for porch railings. Tapered wood
columns were also a common means of supporting the
porch roof. The porch was typically covered at the front
under a low-sloped roof that extended from the main
gable. Roofs were steep gables supported by decorative
brackets, with multiple perpendicular gables. A large
dormer on the front and back of the gable was typical
of the craftsman style.
Ranch
The ranch style of construction originated in the
Southwest where it became the dominant style from
the mid-1930s to the present. This style is defined by
a one-story, rambling layout, which was made possible because of the mild climate and plentiful land
on which such houses were built. The roof was lowpitched, with a large overhang to block the summer
sun. The major exterior material was usually stucco or
adobe. Common features of the ranch style were long,
horizontal, single-level construction covered with a
low-sloped roof with large overhangs. The floor plan
was usually arranged in an asymmetrical shape using
a rectangle, L-shaped, or U-shaped design. No matter
the shape, the floor plans usually featured simple,
open spaces with very few interior walls. Figure 11-48
shows a modern adaptation of the ranch style.
Contemporary Homes
FIGURE 1149 Contemporary homes are built to meet a wide
variety of needs. Courtesy Janice Jefferis.
rarely would the traditional floor plan of one of those
houses be desired. Quite often the floor plans of older
houses produced small rooms with poor traffic flow. A
designer must take the best characteristics of a particular style of house and work them into a plan that best
suits the needs of the owner.
Contemporary, or modern, does not denote any
special style of house. Some houses are now being
designed to meet a wide variety of needs, and others
reflect the lifestyle of the owner. Figure 11-49 through
Figure 11-53 show examples of the wide variety of
contemporary houses. Some houses, such as the home
in Figure 11-49, are now being designed to meet a
wide variety of needs. Other homes like the home in
Figure 11-50 are custom-designed to reflect the lifestyle of the owner. No matter the style that is favored,
several recent trends in new-home construction are
helping buyers realize their dreams. The most popular
It is important to remember that a client may like the
exterior look of one of the traditional styles, but very
FIGURE 1148 Ranch-style homes feature a one-level elongated
floor plan covered by a low-sloping roof. Courtesy Piercy & Barclay
Designers, Inc., CPBD.
FIGURE 1150 Many contemporary homes use clean lines
with little or no trim to provide an attractive structure. Design by
Jack Smuckler, A.I.A.; photo by Jerry Swanson. Courtesy California Redwood
Association.
228
GOING
GREEN
Green Styles
The selection of the floor plan style will have a major
impact on the efficiency of a home, and will affect
the home style. The selection of one home style over
another can be a major consideration in designing a
home that is energy efficient. The choice of floor plan
style should be influenced by the site topography and
the living style of the owners. Credits are given by
both Leadership in Energy and Environmental Design
(LEED) and the National Green Building Standards
(NGBS) for designing for infill sites. These sites are often
difficult to build on due to steep grades. Selecting a
suitable floor plan style can greatly reduce the cost of
the construction, eliminate extensive grading, reduce
water runoff, and help to blend the home to the
existing topography.
The floor plan type will also affect the home style to
be used. Although a single-level home can be created
with Victorian features, the style is more suited for
multilevel homes. As you’ve learned in earlier chapters,
multilevel homes can take advantage of the natural
convection to circulate heat from the lower floors to
rooms in the upper floors. Placing dormers above the
upper living areas allows heated air to be exhausted from
the building envelope, providing natural ventilation for
summer cooling. Incorporating home styles that feature
large overhangs on the south and west walls to protect
fenestration from direct sunlight will also affect the style
of the home to be selected. Home styles that incorporate
covered porches, porticos, or decks to provide protection
from the south and west summer sun are green design
features that increase the livability of the home.
The blending of the exterior and interior of the
home can often incorporate green ideas to make
homes more energy efficient. Future chapters will
introduce methods of incorporating green design
in the orientation of the home. The homes in
Figure 11-51 are designed as zero-lot-line homes
to provide all the benefits of home ownership
without the problem of land maintenance. By sharing
a common wall, this style of building eliminates
materials by decreasing the lumber and siding materials
needed to frame the sidewalls for each unit. The use
of zero-lot-line construction also maximizes the use
of available land. The home in Figure 11-52 uses a
passive solar greenhouse on the right, and a sunroom
on the left side to increase the heating efficiency of an
otherwise traditional home. The home in Figure 11-53
is ideally suited to very cold climates by incorporating
FIGURE 1151 Many homes are now being constructed that
have a common property line. Courtesy Western Red Cedar Lumber
Association.
FIGURE 1152 Although this elegant residence reflects no
particular style, it has pleasing proportions, symmetry, and
balance. Courtesy BOWA Builders, Inc. Greg Hadley, photographer.
GOING
GREEN
229
Green Styles (Continued)
a sunroom with its large use of glass for solar gain,
with its subterranean design. Using concrete walls
provides a storage medium for the sunlight collected
through the fenestration, and the bermed earth
provides protection for the walls and ceiling from
harsh winter weather. The green roof also provides
an effective means of reducing water runoff typically
associated with a standard roof. Each of these design
concepts will be explored in future chapters.
FIGURE 1153 Subterranean construction is energy efficient in
severe climates. Courtesy Weather Shield Mfg., Inc.
floor plans offer flexibility, adaptability, and plenty of
room to grow. A new home can usually incorporate
features of any architectural style because decorative details don’t dictate the size and placement of
the rooms. As you explore the design possibilities
throughout this text, give consideration to the following trends that are popular in early twenty-firstcentury homes:
●
Open, informal spaces—Because of high building costs and family lifestyles, most home buyers
prefer an informal “great room” rather than formal
rooms for entertaining. Combining the family room
with the dining area gives the home a greater sense of
spaciousness. A half wall or a work counter defines
the kitchen area while allowing unobstructed views.
● Fewer hallways—Homes with fewer hallways have
an open, airy feeling. Instead of long, dark corridors,
rooms flow together with doors leading directly to
a living area or other shared space. The home may
appear larger because less square footage is spent on
passageways.
● Bonus rooms—A spare room near the kitchen, over
the garage, or in another area apart from the bedrooms provides extra value when a home is not
designed for a specific buyer. These bonus rooms
give buyers extra space that can serve many functions
such as a play area, a multimedia home theater, an
art studio, a workshop, an exercise room, a high-tech
home office, or a quiet sanctuary.
● Spacious laundry room—No longer relegated to the
garage or basement, a cleaning center should be
bright, spacious, and conveniently located. Common
locations include near the kitchen or bedrooms. The
area should provide space for the basic appliances
of a utility room in addition to space for storage of
sewing or craft supplies. Some designers use this
area as a multipurpose room with ample cabinets,
play space for children, and room for crafts and
other hobbies.
● Ample storage space—Walk-in closets, linen closets,
dressing rooms, pantries, and easy-to-reach kitchen
cabinets add enormous appeal to any home.
● Accessibility—Many buyers are seeking homes that
can comfortably accommodate family members or
guests with mobility problems or visual impairments. Fewer stairs, wider doors and hallways, and
larger bathrooms make a home easier to navigate.
One-story homes are increasingly popular with baby
boomers. Two-story homes with the master bedroom
suite on the main level and additional sleeping areas
upstairs are also very popular.
● Spacious garages—SUVs, snowmobiles, jet skis and
other recreational vehicles make spacious garages
a must for many families. Two-car garages are
230
Architectural Drafting and Design
considered the minimum, but many buyers opt for
an even wider three-car garage.
● Sliding partitions—Movable partitions, sliding
doors, pocket doors, or other types of movable
partitions allow flexibility in living arrangements.
With partitions, a great room can be transformed
ADDITIONAL RESOURCES
See CD for more information
One of the best ways to improve your ability to design
pleasing homes is to view successful designs. Excellent
sources for review include magazines, television, and
the Internet. To increase your reading options, use
your favorite search engine and research major listings such as architectural magazines, interior design
magazines, and home magazines. Magazines used by
designers include:
Architectural Digest
Architectural Record
Engineering News Record
Environmental Design
and Construction
Old House Journal
Residential Architect
Traditional Home
Information about each program can be obtained by
accessing www.hgtv.com, www.tlc.discovery.com, or
by using a search engine to search the Internet. Other
Web sites that promote interior design include:
Address
www.greatbuildings.com
www.homeportfolio.com
www.about.com
www.iida.org
If you have access to cable or satellite television, HGTV
and DIY provide an excellent selection of programs that
explore interior design and construction. New programs
are aired each season, so be sure to check program listings or the Web sites of your favorite stations for available
programs. Current popular programs include:
Before and After
Curb Appeal
Dream Drives
into a more intimate living area and a secluded
dining room.
● Outdoor living—The yard and garden become a part
of the floor plan when sliding glass doors lead to
decks, patios, and porches. Upscale features include
outdoor fireplaces, grills, and wet bars.
www.excelhomes.com
Company, Product,
or Service
Documents thousands of
structures and offers many
related links
Features a home design
directory
Home-planning guides on
the Internet
International Interior Design
Association
Links to design-related Web
sites
Dream House
Extreme Homes
Homes Across America
Exterior Design Factors Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet of notebook paper, as follows:
1. Letter your name, Chapter 11 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You
do not need to write out the question. Answers may be prepared on a word processor if course guidelines allow it.
Question 11–1 Explain how the neighborhood can
influence the type of house that will be built.
Question 11–2 Describe how lines can be used in the
design of a structure.
Question 11–3 Sketch a simple two-bedroom house in
two of the following shapes: L, T, U, or V.
Question 11–4 List four functions of a review board.
Chapter 11: Exterior Design Factors
Question 11–5 Describe four floor plan styles, and explain
the benefits of each.
Question 11–6 What factors make a two-story house
more economical to build than a single-story house
of similar size?
Question 11–7 What house shape is the most
economical to build?
Question 11–8 Photograph or sketch examples of the
following historical styles found in your community:
a. Dutch colonial
b. Garrison
c. Saltbox
d. Victorian
Question 11–9 What forms are most typically seen in
residential design?
231
Question 11–16 Sketch a Dutch colonial house.
Question 11–17 Sketch or photograph a house in your
community built with a traditional influence, and
explain which styles this house has copied.
Question 11–18 What are some of the drawbacks of a
traditional style?
Question 11–19 What are the common proportions of
classical Greek design?
Question 11–20 What style of residence has two full
floors with a wraparound porch covered with a hip
roof?
Question 11–21 Define the following terms and list the
styles with which they are associated:
a. Portico
b. Quatrefoil window
Question 11–10 List and define the three terms used to
describe color.
c. Baluster
Question 11–11 Identify the primary and secondary colors.
e. Palladian window
Question 11–12 List the major features of the following
styles:
a. Ranch
b. Tudor
c. Cape Cod
d. Spanish
Question 11–13 How is a tint created?
Question 11–14 Photograph or sketch three contemporary
houses that have no apparent historical style.
Question 11–15 What period of architecture influenced
the Georgian style?
d. Corbel
Question 11–22 List differences between the Georgian
and Federal styles.
Question 11–23 Explain key features of a Foursquarestyle home.
Question 11–24 Explain key features of a prairie-style
home.
Question 11–25 Use the Internet and research a home
style that is popular in your area. Explain key features
of the style you selected, and explain why that style
is suited to your area.
CHAPTER 12
Conservation and
Environmental Design
and Construction
I
N
T
R
O
D
U
C
T
I
O
N
Conservation design uses different technologies to improve
construction methods and provide alternative energy
sources. Architects, architectural designers, building contractors, and home buyers today are concerned about quality
of life on the earth and in the home. Improving energy efficiency is a good way to reduce oil dependency and address
environmental concerns. Throughout North America, private, local, state, and national agencies sponsor projects that
provide incentives and education for architects, designers,
and builders in an effort to create buildings that are good for
the earth today and into the future. The terms environmentally friendly and environmentally sound refer to designing
and constructing buildings with renewable materials such as
wood from certified forests, earthen materials, and recycled
products. These buildings are healthier because nontoxic
and low-toxicity materials are used. Energy from renewable
resources, such as geothermal, solar, photovoltaic, or wind
energy is also taken into consideration in protecting the
environment and reducing the carbon footprint. A carbon
footprint, as defined by Wikipedia, is “a measure of the impact
human activities have on the environment in terms of the
amount of greenhouse gases produced, measured in units
of carbon dioxide.” The carbon footprint measurement is
meant to be useful for individuals, nations, and organizations
to conceptualize their personal or organizational impact in
contributing to global warming. A theoretical tool to reduce
the impact of carbon footprints, carbon offsets, are the
lessening of carbon emissions through the development of
alternative projects such as solar or wind energy, or reforestation. Greenhouse gases are the gases that absorb global
radiation and contribute to the greenhouse effect. The
main greenhouse gases are water vapor, methane, carbon
dioxide, and ozone. The greenhouse effect is atmospheric
heating caused by solar radiation being readily transmitted inward through the earth’s atmosphere but long-wave
radiation less readily transmitted outward, due to absorption
by certain gases in the atmosphere.
Reducing emissions from all greenhouse gas sources can
help produce a carbon neutral result through energy
efficiency, renewable energy purchases, and carbon offset
232
purchases. Here are five ways you can reduce your carbon
footprint:
1. Build an efficient home with materials that reduce or
eliminate carbon dioxide emissions; consider renewable energy to heat and cool your home.
2. Install energy- and water-efficient appliances and
mechanical systems in your home.
3. Purchase items that have a low carbon footprint from
responsible manufacturers.
4. Carpool, use mass transit, or plan your trips to
reduce driving.
5. Participate in programs that aim to offset carbon
dioxide emissions. Many companies offer programs
to offset your carbon dioxide emissions, which often
include donations to renewable energy or tree planting programs.
(Source: Mascord Efficient Living, Building a More Sustainable Lifestyle.)
ENERGY-EFFICIENT DESIGN
For decades, energy-conscious individuals have been
experimenting with energy-efficient design and construction. Their goal has been to reduce home heating and
cooling costs. In recent years, as a result of rising energy
costs, several formal studies have been done around the
country, sponsored by various private and governmental
agencies that are committed to conservation. The experimental programs have included the following goals:
●
Conserve natural resources.
● Save the environment.
● Preserve the earth’s ozone layer.
● Create a better and healthier living environment.
● Meet consumers’ demand for more economical living.
● Evaluate realistic material and construction alternatives that can be used to alter building codes in
the future.
Today’s home buyers are concerned about energyefficient design. They expect energy-efficient design
GOING
GREEN
233
An Overview
A special feature called Going Green is found
throughout this textbook, providing current practical
and experimental energy-efficient architectural design
and construction techniques resulting in a significant
reduction in energy consumption. As the building
industry grows to meet the demands of our increasing
population, there is a strong need to take care of
the environment and allow for current and future
development. As a student, it is very important for you to
learn what is available today and to find ways to improve
energy efficiency in architectural design and construction
in the future in an effort to protect the earth. National
and local programs have been established to meet this
need. A leading program is often referred to as green
building. The U.S. Green Building Council (USGBC) is a
key organization developed to promote building design
and construction that is environmentally responsible and
healthy, while allowing construction to remain profitable.
Modern advances in building construction are available
to designers, builders, and owners who want to “build
green” and make the most of environmental protection
in the architectural and construction industries.
and construction to be a part of the total home package. In many cases, green design and construction can
be achieved without a great deal of additional cost.
Consumers look for design and construction that uses
high-quality insulation, air infiltration barriers, proper
caulking, energy-rated windows, and other quality
materials. Consumers also look for energy-efficient
appliances and cost-saving improvements such as solar
heat. These design and construction practices increase
comfort while reducing energy costs.
Home builders around the country have realized
the advantages of energy-efficient design and construction for consumers and themselves. An energy-efficient
home is easier to sell than a home built without energyefficient design and construction.
In several controlled situations where energyefficient construction techniques were implemented
to determine if there would be a significant reduction
in energy consumption, the results clearly showed a
savings. A number of techniques can be used that do
not cost much more than standard construction; however, at the other extreme, some energy-conserving
design and construction methods are complex and
labor- and material-intensive. The following describes
a variety of energy conservation architectural design
and construction programs and practices.
buildings are buildings capable of maintaining their
desired function into the future. LEED represents every
part of the construction industry.
As taken from the USGBC Web site, LEED was created to:
THE LEED PROGRAM
The U.S. Green Building Council (USGBC) members
came together to create a standard for green building,
called the Leadership in Energy and Environmental
Design (LEED) Green Building Rating System. This
rating system is a national standard for developing
high-performance, sustainable buildings. Sustainable
●
Define “green building” by establishing a common
standard of measurement.
●
Promote integrated, whole-building design practices.
●
Recognize environmental leadership in the building
industry.
●
Stimulate green competition.
●
Raise consumer awareness of green building benefits.
● Transform the building market.
LEED has a commercial building certification
program that started in 2000 that recognizes commercial construction projects demonstrating the
highest sustainability performance standards. LEED
certification requires that the project meet the fundamentals, and score a minimum number of points in a
LEED rating system. In the LEED program, various
levels of certification are applied to new buildings
and rehabilitated structures. The objective is for
the building to earn enough points to qualify for
Platinum, Gold, or Silver levels of certification. The
LEED rating system and its relationship to national
building codes is discussed in Chapter 9.
The LEED for Homes Program
The LEED for Homes program started in 2007 for
residential architecture. Contents of this discussion are
taken in part from the LEED for Homes and the Green
234
Home Guide Web sites. LEED for Homes is a rating
system that promotes the design and construction of
high-performance green homes. A green home uses
less energy, water, and other natural resources; creates less waste; and is healthier and more comfortable
for the occupants. Benefits of a LEED home include
lower energy and water bills; reduced greenhouse gas
emissions; and less exposure to mold, mildew, and
other indoor toxins. LEED certification allows buyers
to identify homes that have been third-party inspected,
performance-tested, and certified as truly green homes
that perform better than standard homes. Home builders using LEED are able to differentiate their homes as
among the best energy-efficient homes on the market.
The LEED for Homes ratings set a minimum level of
performance in the following eight categories:
1. Innovation and design. This category encourages
project planning and design to improve the coordination and integration of the various elements
in a green home. Credits are earned for innovative
designs, exemplary performance, or regional bestpractices that can be shown to produce proven environmental and human health benefits. Innovation
and design includes involving key representation
from building design, energy engineering, performance testing, sustainable design, civil engineering,
landscape architecture, habitat restoration, land-use
planning, and a LEED representative in the preliminary and final design.
2. Location and linkages. The placement of homes in
socially and environmentally responsible ways in
relation to the larger community provides credits
toward LEED certification. The term linkages means
that the specific home site is environmentally linked
to the community. Location and linkages address
how builders select site locations that promote
environmentally responsible land-use patterns and
neighborhoods. Location and linkages credits reward
builders for selecting home sites that have more
sustainable land-use patterns and offer advantages
over conventional developments. Land is used more
efficiently, reducing the acreage needed for new
housing. Division of farmland, forest, and other natural areas is minimized. Well-sited developments need
fewer roads, water, and sewer lines. These developments promote a range of sustainable transportation
options, including walking, cycling, and mass transit.
3. Sustainable sites. This category awards projects for
minimizing site impacts allowing natural elements
to have a significant environmental impact. Proper
placement of the home on the site can have major
long-term effects on local and regional ecosystems,
Architectural Drafting and Design
and reduce demand for water, chemicals, and pesticides for site management. Good design decisions
can result in attractive, easy-to-maintain landscaping
that protects native plant and animal species and contributes to the health of local and regional habitats.
Erosion, chemical, and pesticide run off from rainfall
are minimized, and rain can be used for potable water
and to recharge aquifers. Potable water is water of a
quality that is suitable for drinking. An aquifer is an
underground bed or layer of earth, gravel, or porous
stone that yields water. Sustainable sites offer enrichment with trees and plants that provide shade, aesthetic value, habitat for native species, and a way to
absorb carbon and enrich the soil.
4. Water efficiency. LEED for Homes credits are given
for the conservation and reuse of inside and outside
water. The use of water-conserving plumbing fixtures and fittings can easily reduce water usage by
over 30% in new homes.
5. Energy and atmosphere. Credits are available for
homes built with energy-efficient construction methods and materials, and for homes that reduce CO2
emissions as a result of improving their environmental performance. According to the Green Home
Guide Web site, the average certified LEED home
uses 30% to 40% less electricity and saves more than
100 metric tons of CO2 emissions over its lifetime.
Modest investments in energy-saving and other
climate-friendly technologies can yield homes and
communities that are healthier, more comfortable,
more durable, energy efficient, and environmentally
responsible places to live.
6. Material and resources. LEED for Homes credits
are given for the use of material-efficient framing
methods, environmentally preferable low-emission
products, and recyclable waste management practices. Reclaimed materials can be substituted for
new materials, saving costs and reducing the use of
natural resources. Recycled-content materials reuse
waste products that would otherwise be deposited in
landfills. LEED for Homes promotes the use of local
materials, which supports the local economy and
reduces the harmful impact of long-distance transport. Use of third-party-certified wood promotes
good stewardship of forests and related ecosystems.
Use of low-emitting materials improves the indoor
air quality in the home and reduces demand for
materials with added volatile, toxic compounds.
Additionally, the builder can separate construction
debris into multiple bins or disposal areas allowing
easier shipment to recycling facilities or pickup by
a waste management company.
Chapter 12: Conservation and Environmental Design and Construction
7. Indoor environmental quality. This LEED for
Homes category can provide a large number of
LEED for Homes credits. This category encourages builders to prevent air pollution and improve
air quality and comfort in the homes they build.
Source removal is the most practical way to ensure
that harmful chemical compounds are not brought
into the home. Evaluating the properties of adhesives, paints, carpets, composite wood products,
and furniture, and selecting materials with low
levels of potentially irritating gas emissions can
reduce occupant exposure. Scheduling deliveries
and sequencing construction activities can reduce
exposure of materials to moisture and absorption
of contaminants. Source control plans focus on
capturing pollutants that are known to exist in a
home. For example, filtering the air supply removes
particulates that would otherwise be continuously
recirculated through the home. Protection of airhandling systems during construction and cleaning
prior to occupancy reduces future problems. Indoor
air quality also contributes to occupant comfort.
The proper installation of automatic sensors and
controls to maintain proper temperature, humidity
and ventilation in occupied spaces helps maintain
the best possible air quality. The use of outdoor air
ventilation, indoor contaminant control, air filtering,
and radon protection are described in Chapter 21 of
this textbook.
8. Awareness and education. Credits are given for the
education of the home owner or tenant, and the building manager. This category promotes broad awareness among home buyers and tenants that LEED
homes are built differently and need to be operated
and maintained in a manner that saves energy, water,
and other resources through the lifetime of the home.
The long-term benefits of LEED measures might not
be achieved without proper training.
LEED for Homes certification ensures that a home is
designed and constructed with the highest quality of
environmental and human protection possible in the
industry. This is because LEED for Homes credits
are given only if the design and construction meet
rigid inspection and third-party testing of the various components that go into building a home. Other
energy-conscious design and construction programs
offer significant improvement in the environmental
and sustainable quality of construction materials and
practices, but they may not have the quality inspection control and testing found in LEED-certified
homes. Additional resources are identified at the end
of this chapter.
235
NATIONAL ASSOCIATION OF HOME
BUILDERS MODEL GREEN HOME
BUILDING
The National Association of Home Builders (NAHB)
started a voluntary program, in 2005, called the Model
Green Home Building Guidelines. This program and
its effect on national building codes are described in
Chapter 9. The following information was taken in
part from the NAHB’s Model Green Home Building
Guidelines Web site. Sustainable, environmentally
friendly, and recycled building products, and the education of builders have increased the residential construction industry’s acceptance of green building. NAHB
members currently build more than 80% of the homes
in this country, and are incorporating green practices
into the development, design, and construction of new
homes. NAHB’s voluntary Model Green Home Building
Guidelines are designed as a tool kit for builders who
want to use green building practices, and for local home
builder associations that want to start their own green
building programs. The NAHB Model Green Home
Building Guidelines include the following categories:
●
Lot preparation and design. Careful site planning
can reduce the impact on natural features such as vegetation and soil, and improve long-term performance
of a home on the site.
●
Resource efficiency. Advanced framing techniques
and home designs can effectively optimize the use of
building materials. Careful material selection can help
reduce the amount of time and money needed for
home maintenance. Also, waste management practices
are used to recycle construction waste materials.
●
Energy efficiency. This category helps the builder
create a better building envelope and incorporate more
energy-efficient mechanical systems, appliances, and
lighting into a home. The results are long-term energy
savings and increased comfort for the home owner.
●
Water efficiency and conservation. The availability
of an adequate water supply is a national concern.
Use of indoor and outdoor water conservation
guidelines reduces water consumption and utility
costs.
●
Occupancy comfort and indoor environmental
quality. Effective management of moisture, ventilation, and other issues can create a more comfortable
and healthier indoor living environment.
●
Operation, maintenance, and education. The features of this category show a builder how to educate
home owners on the features of their new green
home. It is important for home buyers to learn how
236
to operate and maintain the green home in a manner
that saves energy, water, and other resources throughout the lifetime of the home.
The NAHB Model Green Home Building Guidelines
help organize the green design and construction process
and help the builder incorporate more green building features into homes. For more information about the NAHB
Model Green Home Building Guidelines, consult the
additional resources at the end of this chapter or contact:
National Association of Home Builders
1201 15th Street, NW
Washington, DC 20005
Web site: http://www.nahbrc.org/greenguidelines
The National Green Building Standard™
The following is taken in part from the National Association of Homebuilders Research Center (NAHBRC)
Web site. In a continuing effort to advance the use of
environmentally responsible technologies in residential
construction, NAHB, the International Code Council
(ICC), and the NAHB Research Center worked together
to develop an American National Standards Institute
(ANSI) standard for green home building construction
practices. Completed on January 29, 2009, the National
Green Building Standard is for all residential construction work including single-family homes, apartments
and condos, land development, and remodeling and
renovation. It is a voluntary green home building standard that can be adopted by local green home building
programs or local building departments as a conformance guide. The standard is publicized as a joint publication between the NAHB and the ICC.
The new standard builds upon the NAHB Model
Green Home Building Guidelines developed by the
NAHB Research Center with participation from a stakeholder group of over 64 organizations representing
various vested interests in residential construction in
the United States.
ENERGY STAR
Energy Star is a joint program of the U.S. Environmental
Protection Agency (EPA) and the U.S. Department of
Energy (DOE) created to help save money and protect
the environment through energy-efficient products and
practices, and through superior product energy efficiency. Energy Star–qualified homes must meet strict
guidelines for energy efficiency set by the EPA. These
homes are at least 15% more energy efficient than homes
built to the 2004 International Residential Code (IRC),
and include additional energy-saving features that typically make them 20% to 30% more efficient than standard
Architectural Drafting and Design
homes. Energy Star homes are independently verified
to meet the requirements. Energy savings are based on
heating, cooling, and hot water energy use and are typically achieved through a combination of:
●
Building envelope upgrades.
● High-performance windows.
● Controlled air infiltration.
● Upgraded heating and air-conditioning systems.
● Tight duct systems.
● Upgraded water heating equipment.
These features contribute to improved home quality, home owner comfort, lower energy demand, and
reduced air pollution. Energy Star also encourages the
use of energy-efficient lighting, appliances, and features
designed to improve indoor air quality.
Verification of a home’s energy efficiency by a third
party is an essential step in getting the Energy Star
label and certificate. Verification is generally dependent
on the construction method used to build the home.
Homes constructed on-site are typically verified using
one of two methods:
1. Home Energy Ratings Systems (HERS) ratings.
2. Builder Option Packages (BOPs).
A HERS rating is an evaluation of the energy efficiency of a home, compared to a computer-simulated
reference house of identical size and shape. The home
being evaluated must meet minimum requirements
of the Model Energy Code (MEC). The HERS rating
results in a score between 0 and 100, with the reference
house assigned a score of 80. The Energy Star–qualified
new home is required to be significantly more energy
efficient than the reference house, by achieving a HERS
score of at least 86.
A BOP is the other manner through which a home
can be qualified as an Energy Star–qualified new home.
A BOP represents a set of construction specifications
for a specific climate zone, based on performance
levels for the thermal envelope, insulation, windows,
orientation, heating, ventilating, and air-conditioning
(HVAC) system, and water heating efficiency for the
climate zone.
THE ENVIROHOME INITIATIVE,
CANADIAN HOME BUILDERS’
ASSOCIATION
The following is taken in part from the EnviroHome
Web site. The EnviroHome Initiative was established
in 1994 by the Canadian Home Builders’ Association
Chapter 12: Conservation and Environmental Design and Construction
(CHBA) and TD Canada Trust to recognize and support
innovative new home builders who are specially trained
and licensed, and committed to offering consumers
homes that are “better for you, better for your community, and better for the environment.” TD Canada
Trust is a full-service bank that provides home loans.
Canadian Home Builders’ Association EnviroHome
projects showcase the best in new home-building
technology and products. EnviroHome builders are
the best, highly innovative, skilled professionals who
know how to construct exceptional homes that meet
the needs of today’s consumers for healthy affordable
homes. EnviroHomes are exceptionally comfortable,
healthy to live in, more energy efficient, and better for
the environment than homes not designed and built to
EnviroHome standards.
Each year the EnviroHome designation is given
to a select number of new home projects across
Canada. To qualify, each home must be certified
to the R-2000 Standard and include additional air
quality and environmental features beyond what
the R-2000 program requires. R-2000 is a specific
Canadian home building technology that has earned
a worldwide reputation for quality, comfort, and
environmental responsibility. Every R-2000 certification involves special measures in three main
areas of construction: energy performance, indoor
air quality, and use of environmentally preferred
materials. R-2000 homes incorporate a range of
cost-effective, energy-efficient building practices
and technologies, regardless of design or size.
R-2000 homes are independently certified to meet a
high level of energy efficiency, beyond what building codes require. With an R-2000 certificate, home
owners can have confidence in the performance of
their home. Builders choose to be part of the R-2000
program because they want access to the best home
building technology available so they can offer their
customers a better home.
ENERGY-EFFICIENT
CONSTRUCTION PRACTICES
The Energy-Efficient Construction Practices
content on the Student CD includes information and
examples about how to decrease dependency on the
heating and cooling system, through the use of framing
techniques such as caulking, vapor retarders, radiant
barriers, and insulation. A discussion about the types of
insulation is included as well. Refer to the Student CD:
ENERGY-EFFICIENT CONSTRUCTION PRACTICES,
for more information.
237
SOLAR ENERGY DESIGN
Sunlight becomes solar energy when it is transferred
to a medium that has the capacity or ability to provide
useful heat. This useful solar energy can be regulated in
order to heat water or the inside of a building, or create
power to run electrical utilities. Most areas of the earth
receive about 60% direct sunlight each year, and in very
clear areas, up to 80% of the annual sunlight is available for use as solar energy. When the sun’s rays reach
the earth, the air and the features on the earth become
heated. Certain dense materials such as concrete can
absorb more heat than less dense materials such as
wood. During the day the dense materials absorb and
store solar energy. Then at night, with the source of
energy gone, the stored energy is released in the form
of heat. Some substances, such as glass, absorb thermal
radiation while transmitting light. This concept, in part,
is what makes solar heating possible. Solar radiation
enters a structure through a glass panel and warms the
surfaces of the interior areas. The glass keeps the heat
inside by absorbing the radiation.
Two basic residential and commercial uses for solar
energy are heating spaces and hot water. Other uses are
industrial and include drying materials such as lumber,
masonry, or crops. Solar energy has also been used for
nearly a century with desalinization plants to provide
fresh water from either mineral or saltwater.
Solar space heating systems are passive, active, or
a combination of the two. Passive solar systems, also
called architectural solar systems, use no mechanical
devices to retain, store, or radiate solar heat. Active solar
systems, also called mechanical solar systems, do use
mechanical devices to absorb, store, and use solar heat.
The potential reduction of fossil fuel energy consumption can make solar heat an economical alternative. A number of factors contribute to the effective
use of solar energy. Among them are energy-efficient
construction techniques and full insulation of a building
to reduce heat loss and air infiltration.
An auxiliary heating system is often used as a backup
or supplemental system in conjunction with solar heat.
The amount of heat needed from the auxiliary system
depends on the effectiveness of the solar system. Both the
primary and the supplemental systems should be professionally engineered for optimum efficiency and comfort.
A southern exposure, when available, provides the
best site orientation for solar construction. A perfect
solar site allows the structure to have an unobstructed
southern exposure. This topic is described further in
Chapter 13.
Room placement is another factor to consider for
taking advantage of solar heat. Living areas, such as the
238
living and family rooms, should be on the south side
of the house, while inactive rooms, such as bedrooms,
laundry room, and bathrooms, should be located on
the north side, if a cooler environment is desirable.
If possible, the garage should be placed on the north,
northeast, or northwest side of the home. A garage can
act as an effective barrier, insulating the living areas from
cold exterior elements. The inactive rooms, including
the bedrooms, bathrooms, laundry room, pantry, and
garage, shelter the living area from the northern exposure. Masonry walls also allow the house to be built
into a slope on its northern side, or berms to be used as
shelter from the elements.
The Air-Lock Entry
Another energy-efficient element of design is an air-lock
entry, known as a vestibule. This is an entry that provides a hall or chamber between an exterior and interior
door to the building. The vestibule should be designed
so the interior and exterior doors are not open at the
same time. The distance between the doors should be at
least 7 feet (2100 mm), to force the occupants to close
one door before they reach the other door. The main
idea behind an air-lock entry is to provide a chamber that is always closed to the living area by a door.
When the exterior door is opened, the air lock loses
heat, but the heat loss is confined to the small space
of the vestibule and the warm air of the living area is
exposed to minimum heat loss.
Architectural Drafting and Design
drapes to allow sunlight to enter and heat the rooms.
In the early evening, before the heat begins to radiate
out of the house, the occupant should close the shutters
or draperies to keep the heat within.
Codes and Solar Rights
Building permits are generally required for the installation of active solar systems or the construction of passive
solar systems. Some installations also require plumbing
and electrical permits. Verify the exact requirements for
solar installations with local building officials. During
the initial planning process, always check the local
zoning ordinances to determine the feasibility of the
installation. For example, many areas restrict dwelling
height. If the planned solar system encroaches on this
zoning rule, then a different approach or a variance to
the restriction should be considered.
The individual’s access to sunlight is not always guaranteed. A solar home can be built in an area that has
excellent solar orientation, and then a few years later, a
tall structure may be built across the street that blocks
the sun. A neighbor’s trees can grow tall and reduce
sunlight. Determine the possibility of such a problem
before construction begins. Some local zoning ordinances, laws, or even deed restrictions can protect the
individual’s right to light. In the past, laws generally provided the right to receive light from above the property
but not from across neighboring land. This situation is
changing in many areas of the country.
Living with Solar Energy Systems
Solar energy and energy-efficient construction require
a commitment to conserving energy. Each individual must evaluate cost against potential savings and
become aware of the responsibility of living with
energy conservation.
Solar systems can be designed that provide some heat
from the sun and require little or no involvement from
the occupant to assist with the process. Such a minimal
energy-saving design is worth the effort in many cases.
Active solar space heating systems are available that can
provide a substantial amount of needed heat energy.
These systems are automatic and also do not generally
require involvement from the home owner, although the
home owner should be aware of operation procedures
and maintenance schedules. Alternately, some passive
solar heating systems require much participation by
the occupants. For example, a mechanical shade must
be used by the home owner to block the summer sun
rays from entering southern-exposure windows. During
the winter months, when the sun is heating the living
area, the heat should be retained as long as possible. In
the morning the home owner needs to open shutters or
Roof Overhang
The sun’s angle changes from season to season. The
sun is lower on the horizon in the winter and higher in
the summer. An overhang can shield a major glass area
from the heat of the summer sun and also allow the
lower winter sun to help warm the home. Figure 12-1
shows an example of how a properly designed overhang
can aid in the effective use of the sun’s heat.
SUMMER SUN
OVERHANG
WINTER SUN
FIGURE 121 Effective overhang.
Chapter 12: Conservation and Environmental Design and Construction
An overhang that provides nearly 100% shading at
noon on the longest day of the year can be calculated
with a formula that divides the window height by a
factor determined in relationship to latitude:
Overhang =
239
SUMMER
WINTER
Windowsill height
F
North Latitude
F
North Latitude
F
28°
8.4
44°
2.4
32°
5.2
48°
2.0
36°
3.8
52°
1.7
40°
3.0
56°
1.4
A DROP SHADE
Example: Calculate the recommended southern overhang for a location at 36° latitude and provide for a windowsill height of 6'–8". Latitude is the angular distance
between an imaginary line around the earth parallel to
the equator and including the equator.
B SLIDING SHADE
6'–8" (Window height)
Overhang (OH)=
3.8 (F at 36° latitude)
=
6.6
=1.8 ≈ 1'–10"
3.8
The recommended overhang is greater for a more
northerly latitude.
Overhang protection can be constructed in ways
other than a continuation of the roof structure; there
is a great deal of flexibility in architectural design. An
awning, porch cover, or trellis can be built to serve the
same function as an overhang. Alternative methods of
shading from summer heat and exposing window areas
to winter sun can be achieved with mechanical devices.
These movable devices require the occupant to be aware
of the need for shade or heat at different times of the
year. Figure 12-2 shows some shading options.
C AWNING SHADE
FIGURE 122 Optional shading devices.
used individually and together, including south-facing
glass, thermal storage walls, roof ponds, solariums, and
envelope construction.
PASSIVE SOLAR SYSTEMS
In passive solar architecture, the structure is designed
so the sun directly warms the interior. A passive solar
system allows sunlight to enter the structure and be
absorbed into a structural mass. The stored heat
then warms the living space. Shutters or curtains are
used to control the amount of sunlight entering the
home, and vents help control temperature. In passive solar construction, the structure is the system.
The amount of material needed to store heat depends
on the amount of sunlight, the desired temperature
within the structure, and the ability of the material
to store heat. Materials such as water, steel, concrete,
and masonry have good heat capacity; wood does not.
Several passive solar architectural methods have been
South-Facing Glass
Direct solar gain is a direct gain in heat created by the
sun. This direct gain is readily created in a structure
through south-facing windows. Large window areas
facing south can provide up to 60% of a building’s heating needs when the windows are insulated at night with
tight-fitting shutters or insulated curtains. When the
window insulation is not used at night, the heat gain
during the day is quickly lost. The sun’s energy must
heat a dense material in order to be retained. Floors and
walls are often covered with or made of materials other
than traditional wood and plasterboard. Floors constructed of or covered with tile, brick, or concrete, and
special walls made of concrete or masonry or containing
240
Architectural Drafting and Design
FIGURE 123 South-facing glass provides direct gain. Courtesy
Residential Designs.
water tubes, can provide heat storage for direct solar
gain applications. Figure 12-3 shows a typical application of direct-gain south-facing glass.
Clerestory windows can be used to provide light
and direct solar gain to a second-floor living area and
increase the total solar heating capacity of a house.
Clerestory windows are a row of windows set along the
upper part of a wall. These clerestory windows can also
be used to help ventilate a structure during the summer
months, when the need for cooling is greater than the
need for heating (see Figure 12-4).
Skylights can be used effectively for direct solar gain.
A skylight is a window in a roof used to admit sunlight.
When skylights are placed on a south-sloping roof, they
provide needed direct gain during the winter. In the
summer, skylights can cause the area to overheat unless
additional care is taken to provide for ventilation or a
shade cover. Some manufacturers have skylights that
open and can provide sufficient ventilation. Figure 12-5
shows an application of operable skylights.
CLERESTORY
WINDOWS
NORTH
SIDE
COOL
AIR
FIGURE 124 Clerestory circulation.
FIGURE 125 Operable skylights can provide sufficient
ventilation. Courtesy VELUX America, Inc.
Thermal Storage Walls
Thermal storage walls are constructed of any good
heat-absorbing material such as concrete, masonry, or
water-filled cylinders. The storage wall can be built
inside and next to a large southern-exposed window or
group of windows. The wall receives and stores energy
during the day and releases the heat slowly at night.
The Trombe wall, designed by a French scientist,
Dr. Felix Trombe, is a commonly used thermal storage wall. The Trombe wall is a massive dark-painted
masonry or concrete wall situated a few inches inside
and next to south-facing glass. The sun heats the air
between the wall and the glass. The heated air rises and
enters the room through vents at the top of the wall. At
the same time, cool air from the floor level of adjacent
rooms is pulled in through vents at the bottom of the
wall. The vents in the Trombe wall must be closable to
avoid losing the warm air from within the structure
through the windows at night. The heat absorbed in the
wall during the day radiates back into the room during
the night hours. The Trombe wall also acts to cool the
structure during the summer. This happens when warm
air rises between the wall and glass and is vented to the
outside. The air currents thus created, work to pull cooler
air from an open north-side window or vent. Figure 12-6
shows an example of a thermal storage wall.
Chapter 12: Conservation and Environmental Design and Construction
241
OPEN VENT TOP AND BOTTOM
WATER-FILLED STRUCTURE
SOUTH
SIDE
STORAGE WALL
MECHANICAL
INSULATION
BLANKET
LIVING SPACE
WINTER DAY USE OF STORAGE WALL
CLOSED VENTS
TOP AND BOTTOM
RADIANT
HEAT
SOME HEAT LOSS
WINTER NIGHT USE OF STORAGE WALL
WARM AIR OUT
VENT OR CLERESTORY
COOLER
AIR
FROM
NORTH
SIDE
WARM AIR
VENTED OUT
SUMMER ACTIVITY OF STORAGE WALL
FIGURE 126 Thermal storage wall.
Some passive solar structures use water as the storage
mass: large vertical water-filled tubes or drums painted
dark to absorb heat are installed as the Trombe wall.
The water functions as a medium to store heat during
the day and release heat at night.
Roof Ponds
Roof ponds are used occasionally in residential architecture, although they are more common in commercial construction. A roof pond is usually constructed
of containers filled with antifreeze and water on a flat
roof. The water is heated during the winter days, and
then at night the structure is covered with insulation,
which allows the absorbed heat to radiate into the living
space. This process functions in reverse during the
summer. The water-filled units are covered with insulation during the day and uncovered at night to allow
any stored heat to escape. To assist the radiation of heat
at night, the structure should be constructed of a good
thermal-conducting material such as steel. Figure 12-7
shows an example of the roof-pond system.
GARAGE,
CARPORT,
AWNING,
COVERED AREA.
FIGURE 127 Roof-pond system.
Green Roof
A green roof is also known as a rooftop garden. These
roofs are planted over existing roof structures to help
reduce building temperatures, filter pollution, and lessen
water runoff. A green roof reduces the urban heat island
effect and potentially tempers heating and cooling loads
in the building. The urban heat island effect means that
city areas are warmer than suburbs or rural areas due
to less vegetation, more land coverage, and other infrastructure. The green roof also slows stormwater runoff
removing the load on the city’s wastewater system.
Solariums
A solarium, sometimes called a sunroom or solar greenhouse, is designed to be built on the south side of a
house next to the living area. Solariums are a nice part
of the living area when designed into a home. Solariums
allow plants to grow well all year.
The theory behind the solarium is that a great
amount of solar energy is absorbed and transmitted
to the rest of the building. A thermal mass can also be
used in conjunction with the solarium. Heat from the
solarium can be circulated throughout the entire house
by natural convection or through a forced-air system.
The circulation of hot air during the winter and cool air
during the summer in the solar greenhouse functions
similar to a Trombe wall.
The solarium can overheat during long, hot summer
days. This potential problem can be reduced by mechanical ventilators or a mechanical humidifier. Exterior
shading devices, which are covers that can be rolled
down over the greenhouse glass area, are often advantageous. The use of landscaping with southern deciduous trees, as discussed in Chapter 13, is a possible
242
Architectural Drafting and Design
VENT OPEN TOP
AND BOTTOM
VENT CLOSED
SOUTH
SIDE
SOLAR
GREENHOUSE
CIRCULATING
WARM AIR
PLANTS
STORAGE MASS
WINTER ACTIVITY
VENT
OPEN
VENT
CLOSED
COOLER
NORTH
AIR
WARM AIR
SUMMER ACTIVITY
FIGURE 128 Solarium construction.
alternative. Figure 12-8 shows how a solarium operates
to provide solar heat and circulate summer cooling.
ENVELOPE DESIGN
The Envelope Design content on the Student
CD includes information and illustrations
about the function and construction of a home using
the envelope design concept. Refer to the Student CD,
ENVELOPE DESIGN, for more information.
local codes should be checked. Active solar systems are
commonly adapted to existing homes or businesses that
normally use a forced-air heating system.
Solar Collectors
As the name implies, solar collectors catch sunlight and
convert this light to heat. Well-designed solar collectors
are nearly 100% efficient.
The number of solar collectors needed to provide
heat for a given structure depends on the size of the
structure and the volume of heat needed. These are
the same kinds of determinations made when sizing
a conventional heating system. Collectors are commonly placed in rows on a roof or on the ground next
to the structure, as shown in Figure 12-9. Architects
and designers are integrating the solar panels into the
total design in an effort to make them less obvious.
The best placement requires an unobstructed southern
exposure. The angle of the solar collectors should be
in proper relationship to the angle of the sun during
winter months, when the demand for heat is greatest.
Verify the collector angle that is best suited for a specific
location. Some collectors are designed to be positioned
at 60° from horizontal so the winter sun hits at about
90° to the collector. Although this is the ideal situation,
a slight change from this angle of up to 15° may not
alter the efficiency very much. Other collectors are
designed to obtain solar heat by direct and reflected
sunlight. Reflecting, or focusing, lenses help concentrate the light on the collector surface. Figure 12-10
shows an example of solar collector tilt.
ACTIVE SOLAR SYSTEMS
Active solar systems are part of a group of green power
systems. Green power, as defined on the Environmental
Protection Agency Web site, is “electricity that is generated from resources such as solar, wind, geothermal,
biomass, and low-impact hydro facilities.”
Active solar systems for space heating use collectors
to gather heat from the sun, which is transferred to a
fluid. Fans, pumps, valves, and thermostats move the
heated fluid from the collectors to an area of heat storage. The heat collected and stored is then distributed to
the structure. Heat in the system is transported to the
living space by insulated ducts, which are similar to the
ducts in a conventional forced-air heating system. An
active solar heating system generally requires a backup
heating system that is capable of handling the entire
heating needs of the building. Some backup systems are
forced-air systems that use the same ducts as the solar
system. The backup system can be heated by electricity, natural gas, or oil. Some people rely on wood- or
coal-burning appliances for supplemental heat, but
Photovoltaic Modules
Photovoltaic technology has been developed and refined.
Photovoltaic modules are now powering thousands of
installations worldwide. Solar photovoltaic systems are
now producing millions of watts of electricity to supply
power for remote cabins, homes, railroad signals, water
pumps, telecommunications stations, and utilities. Uses
for this technology are continuing to expand, and new
installations are being constructed.
Photovoltaic cells turn light into electricity. The
word photovoltaic is derived from the Greek photo,
“light,” and voltaic, “to produce electricity by chemical
action.” Photons strike the surface of a silicon wafer,
which is a semiconductor diode, to stimulate the release
of mobile electric charges that can be guided into a circuit to become a useful electric current.
Photovoltaic modules produce direct current (DC)
electricity. This type of power is useful for many applications and for charging storage batteries. When alternating current (AC) is required, DC can be changed to AC
Chapter 12: Conservation and Environmental Design and Construction
243
FIGURE 129 Typical applications of solar hot water collectors. Courtesy Lennox Industries, Inc.
by an inverter. Some photovoltaic systems are designed
to use the energy produced immediately, as is often the
case in water-pumping installations. If the energy produced by solar electric systems is not used immediately,
or if an energy reserve is required for use when sunlight
is not available, the energy must be stored. The most
common storage devices are batteries.
Although both DC and AC systems can stand alone,
AC systems can also be connected to a utility grid.
During times of peak power usage, the system can draw
on the grid for extra electricity if needed. At other times,
such a system can return extra power to the grid. In
most areas of the country the utility (grid) is required to
purchase excess power from private sources.
Precise site selection is vitally important. The
solar modules should be situated where they receive
maximum exposure to direct sunlight for the longest
period of time every day. Other considerations are
distance from the load (appliance); shade from trees
or buildings, which changes with the seasons; and
accessibility.
The future looks bright for solar technologies. The
costs and efficiencies of high-technology systems are
improving. As home owners watch their heating and
cooling costs rise and become more concerned about
shortages of oil and gas, solar heating becomes an attractive alternative. In preparing a preliminary design, solar
alternatives should be considered. A qualified solar engineer should evaluate the site and recommend solar
design alternatives. Additional assistance is usually available from the state or national Department of Energy.
Storage
60°
SOUTHERN
SOLAR
COLLECTOR
WINTER
SUN
COLLECTOR
80°
REFLECTOR
10°
FIGURE 1210 Solar collector tilt.
During periods of sunlight, active solar collectors transfer heat energy to a storage area and then to the living
space. After the demand for heat is met, the storage
facilities allow the heat to be contained for use when
solar activity is reduced, such as at night or during
cloud cover.
The kind of storage facilities used depends on the
type of collector system used. There are water, rock,
and chemical storage systems. Water storage is excellent because water has a high capacity for storing heat.
Water in a storage tank is used to absorb heat from a
collector. When the demand for heat exceeds the collector’s output, the hot water from the storage tank
is pumped into a radiator, or through a water-to-air
heat exchanger for dispersal to the forced-air system.
Domestic hot water can be provided by a water-to-water
heat exchanger in the storage tank.
Rock storage is often used when the collectors contain air rather than water. Heated air flows over a rock
244
storage bed. The rock absorbs some heat from the air
while the balance is distributed to the living space.
When the solar gain is minimal, cooler air passes over
the rock storage, where it absorbs heat and is distributed by fans to the living space. Domestic hot water
may also be provided by an air-to-water heat exchanger
situated in the rock storage or in the hot air duct leading from the collector.
Chemicals used in collectors and in storage facilities absorb large amounts of heat at low temperatures.
Many of these systems claim to absorb heat on cloudy
days or even when the collectors are snow covered.
Chemicals with very low freezing temperatures can
actually absorb heat during winter months, when the
outside temperature is low.
Solar Architectural Concrete Products
Solar collectors can be built into a patio, driveway,
tennis court, pool deck, or tile roof.
Solar architectural concrete products make the most
versatile solar collector on the market. These products
can be used as a driveway, sidewalk, patio, pool deck,
or roofing material, or as the side surface of a building wall or fence. The finished surface can resemble
cobblestone, brick, or roof tiles. Pigments are added
to the specially formulated material, giving it a lasting
color that is pleasing to the eye. These solar products
are completely different from all other solar collectors
in that they add to the aesthetic value of the property.
They are manufactured from a specially formulated
mixture that is strong, dense, very conductive, and
waterproof. Solar architectural cement products absorb
and collect heat from the sun and outside air and
transfer the heat into water, glycol, or another heattransferring fluid passing through embedded tubes.
Architectural Drafting and Design
FIGURE 1211 Groundwater system. Courtesy Solar Oriented
Environmental Systems, Inc.
tubing around a heat exchanger. Direct exchange represents only a small number of geothermal systems and
the Air Conditioning and Refrigeration Institute does
not recognize these.
A geothermal system operates by pumping groundwater from a supply well and then circulating it through
a heat exchanger, where either heat or cold is transferred
by a refrigerant. The water, which has undergone only
a temperature change, is then returned through a discharge well back to the strata, as shown in Figure 12-11.
Lakes, rivers, ponds, streams, and swimming pools may
be alternate sources of water. Rather than pumping the
water up to the heat exchanger, a geothermal exchanger
can be inserted into a lake, river, or other natural body
of water to extract heat, as shown in Figure 12-12.
To cool, the geothermal heat pump extracts heat from
within the structure and transfers it to the fluid, where
the heat dissipates into the ground as it circulates.
Another alternative is to insert a geothermal Freon
exchanger directly into a well, where the natural
GEOTHERMAL SYSTEMS
Geothermal heating and cooling equipment is designed
to use the constant, moderate temperature of the
ground to provide space heating and cooling, or domestic hot water, by placing heat exchangers in the ground,
or in wells, lakes, rivers, or streams. The basic types of
geothermal systems are water- and refrigerant-based.
The water-based system has closed-loop and open-loop
options. The closed-loop system has water or waterantifreeze fluid pumped through polyethylene tubes.
The open-loop system has water pumped from a well or
reservoir through a heat exchanger, and is then discharged into a drainage ditch, a field tile, a reservoir, or
another well. The refrigerant-based system is also known
as direct exchange where refrigerant flows in copper
FIGURE 1212 Geothermal Freon exchanger in a lake. Courtesy
Solar Oriented Environmental Systems, Inc.
Chapter 12: Conservation and Environmental Design and Construction
245
FIGURE 1213 Geothermal Freon exchanger in a well. Courtesy
Solar Oriented Environmental Systems, Inc.
FIGURE 1215 Ground-loop system. Courtesy Solar Oriented
Environmental Systems, Inc.
convection of the groundwater temperature, assisted
by the normal flow of underground water in the
strata, is used to transfer the hot or cold temperature
that is required. Sometimes the thermal transfer must
be assisted by forcing the Freon to circulate through
tubes within the well by a low-horsepower pump (see
Figure 12-13).
A geothermal system may assist a solar system that
uses water as a heat storage and transfer medium.
After the water heated by solar collectors has given up
enough heat to reduce its temperature to below 100°F,
this water becomes the source for operating the geothermal system (see Figure 12-14).
When an adequate supply of water is unavailable, the
ground, which always maintains a constant temperature
below the frost line, can be used to extract either heat or
cold. The thermal extraction is done through the use of
a closed-loop system consisting of polyethylene tubing
filled with a glycol solution and circulated through
the geothermal system. One such system is shown in
Figure 12-15. Another method is to use a vertical dryhole well, which is sealed to allow it to function as a
closed-loop system, as shown in Figure 12-16.
The geothermal system is mechanically similar to
a conventional heat pump, except that it uses available water to cool the refrigerant or to extract heat, as
opposed to using 90°F air for cooling or 20°F to 40°F
air for heating. The conventional heat pump is described
in Chapter 21. The difference between air source and
ground or water sources is that air temperature can
change much more than ground or water temperatures.
This gives the ground or water source heat pump more
capacity and makes it more efficient. Water can store
great amounts of geothermal energy because of its high
specific heat, which is the amount of energy required to
raise the temperature of any substance 1°F. The specific
heat of air is only 0.018, so it can absorb and release
only 1/50 of the energy that water can. To produce a
given amount of heat, 50 times more air volume than
water is required to pass through the unit.
FIGURE 1214 Solar-assisted system. Courtesy Solar Oriented
Environmental Systems, Inc.
FIGURE 1216 Vertical-dry system. Courtesy Solar Oriented
Environmental Systems, Inc.
246
Architectural Drafting and Design
WIND ENERGY
BIOPOWER
Wind energy is a form of solar energy. Winds are
caused by the uneven heating of the atmosphere by
the sun, the irregularities of the earth’s surface, and the
earth’s rotation. Wind turbines capture energy from
the wind. A wind turbine is turned by the wind passing
over propellers that power an electric generator, creating a supply of electricity. Large-scale applications use
several technologically advanced turbines grouped
together in what is referred to as a wind farm. This
wind power plant generates electricity that is fed into
a local utility for distribution to customers. Small-scale
wind turbines are also available for home or business
use. The wind speed in an area determines the effectiveness of possible power generation by wind. Good
wind areas have an annual minimum average wind
speed of 13 miles per hour. Contact your state or the
U.S. Department of Energy to determine if your area is
a good location for wind power.
The advantage of wind energy is that the source is
a free, renewable, clean resource. However, you must
have a good location where wind is available, the
initial cost is a factor to consider, there is some noise
from the turbines, and mortality of birds flying into
the turbines is a concern. The initial cost is balanced
out over time when compared with the cost of fuels
used for other systems. It is possible that wind power
could produce over 10% of the energy needs of the
United States by 2050.
The following was taken in part from the Web site of
the USA Biomass Corporation. Biomass means natural
material, such as trees, plants, agricultural waste, and
other organic material. Organic material is any material
that originated as a living organism. In this context, biomass refers to plant matter grown to generate electricity
or produce biofuel, but it also includes plant or animal
matter used for production of fibers, chemicals, or heat.
Biomass can also include biodegradable wastes that can
be burned as fuel. Biomass excludes organic material
that has been transformed by geological processes into
coal or petroleum, because they contain carbon that has
been “out” of the carbon cycle for a very long time. Coal
and petroleum combustion increases the carbon dioxide
content in the atmosphere.
Biomass energy, also referred to as biopower, uses
biomass to generate electricity in a way that is cleaner
and more efficient than most other electricity generation techniques. Biomass-generating facilities typically
use natural biofuels to produce steam, which drives a
turbine that turns a generator to produce electricity.
In addition to providing clean energy, biopower protects the environment by preventing scrap lumber, agricultural cuttings, forest debris, and other organic waste
from being open-burned or dumped in landfills.
The benefits of biopower include:
HYDROELECTRIC POWER
Hydroelectric generators convert the energy from
falling water into electricity. Hydroelectric power is
a renewable resource, which supplies about 15% of
the electricity needs in the United States and about
60% in Canada. Although hydroelectric resources are
abundant, there is environmental concern about dams
blocking the natural river flow.
Hydroelectric power for residential and business
use is dependent on a good source of flowing water.
The two key factors are flow rate and the vertical
distance that water falls, which is referred to as head.
The site should be evaluated and tested by a hydrology engineer to determine its feasibility. Local codes
and environmental regulations must be considered
before planning a hydroelectric project. Power produced from hydroelectric sources is clean, and this
makes it an excellent consideration when compared
with power plants fired by fossil fuels. However, other
environmental impacts, such as fish passage, must be
considered.
●
Biopower is twice as effective at reducing greenhouse gases as other forms of renewable energy,
helping reduce America’s dependence on fossil fuel–
generating facilities.
● Biopower is carbon neutral, releasing no new carbons
into the atmosphere, helping to reduce the greenhouse gases that contribute to climate change.
● Biopower reduces carbon dioxide emissions by over
15 tons annually, while diverting over 25 million tons
of organic materials that would otherwise decompose,
be open-burned, or accumulate in the forest as overgrowth material.
● Biopower improves the health of American forests
and reduces fire-fighting costs by clearing millions of
tons of forest waste annually, which otherwise would
be fuel for deadly forest fires.
HEALTHY ARCHITECTURAL DESIGN
AND CONSTRUCTION
Constructing a healthy building involves issues related
to construction techniques, construction materials, as
well as heating, ventilating, and air-conditioning design.
Many of the proper construction methods have been
Chapter 12: Conservation and Environmental Design and Construction
247
discussed throughout this chapter. Techniques that
result in energy-efficient construction are important
because the goal is to design and build an airtight structure. The methods used to reduce outside air infiltration range from the selection and proper installation of
insulation and caulking products to the installation of
continuous vapor retarders.
The risks involved in building an airtight structure
involve air quality; these risks range from stale air to a
buildup of harmful contaminants. These issues can be
addressed with a well-designed and properly installed
heat recovery and ventilation system. Sources of pollutants and methods used to deal with these problems
are discussed in Chapter 21, with complete coverage
of HVAC systems. The selection of building materials
and products is also an important consideration. Avoid
manufactured wood products such as fiberboard, particleboard, and plywood unless they are manufactured
using environmentally safe processes and adhesives.
Use water-based caulking, paint, and finishes. Keep
carpeting to a minimum, or eliminate it completely
for very sensitive clients. An alternative to synthetic
carpeting is natural fiber products such as wool and
cotton. Combustion appliances that use gas fuel, such
as furnaces, ranges, water heaters, and clothes dryers,
must be properly ventilated, and combustion must be
complete. An electric or heat pump furnace; electric
water heater, range, and dryer; or sealed combustion
appliances should be considered. Avoid treated wood
products in the construction of the building envelope,
although they may be considered for outside use, as
in decks. In regions where treated wood is commonly
used for termite and rot control, steel-frame construction is a consideration. Steel-frame construction has
been commonly used in commercial structures and is
becoming a serious consideration for residential design
and construction.
The following is a checklist of features and products that can be considered for designing a healthy
structure:
●
●
Design and build with high-quality environmentally
friendly insulation, caulking, and vapor barriers.
●
Use airtight well-insulated wood- or metal-frame
windows.
●
Use unbleached plasterboard and plaster rather than
chemically produced sheetrock and materials.
●
Install a properly designed heat recovery ventilation
system, also called an air-to-air heat exchanger. See
Chapter 21 for more information.
●
Install a high-performance particle air filtration
system. See Chapter 21 for more information.
The following is taken in part from the National
Brownfield Association (NBA) Web site. The National
Brownfield Association is a nonprofit, member-based
organization consisting of NBA U.S.A. and NBA Canada.
The NBA is the only nonprofit organization dedicated
to promoting sustainable development and encouraging green building on brownfield sites. Brownfields, as
defined by the U.S. Environmental Protection Agency,
are “real property, the expansion, redevelopment, or
reuse of which may be complicated by the presence
or potential presence of a hazardous substance, pollutant, or contaminant.” Brownfield sites can be found
Use low-toxicity ceramic tiles and hardwood floors
or natural fiber carpets rather than synthetic carpets.
● Use wood sheathing and decking such as tongueand-groove rather than plywood and particleboard.
Low-formaldehyde products can be considered.
● Consider low-toxicity foam insulation or other nonchemical insulation products.
● Use water-base, solvent-free, low-toxicity paints and
finishes.
● Construct a tightly sealed foundation to help keep
out radon gas and moisture. Radon gas is discussed
in Chapter 21.
● Use a heat pump such as a geothermal unit that
produces no indoor pollutants. Heat pumps are
described in Chapter 21.
● Install gas appliances and fireplaces that use only
outdoor air and exhaust to the outside without any
downdraft.
● Use ultraviolet (UV) lights mounted inside the duct
work, so when the furnace fan circulates air from
the house, the air passes across the UV light rays
which neutralize up to 98% of microorganisms.
Additional information about UV lights is provided
in Chapter 21.
● Install an electrical system that is designed to reduce
stray voltage. Some people are sensitive to power
surges.
● Use a sealed and well-balanced metal duct system.
Avoid fiberglass insulation ducts. Metal ducts can be
insulated on the outside.
● Install a central vacuum system that vents particles
out of the house into a filtered container in the garage.
● Install a garage ventilation system.
● Use ceramic roofing.
Sustainable Development and Green
Building on Brownfield Sites
248
GOING
GREEN
The Ultimate Urban Green Home
This ultimate urban green home, designed by res
communis, is an almost perfect sustainable and
self-sufficient design using super, energy-efficient,
environmentally safe materials and clean energy
technologies. The owners named this home the
Commons, because the ideas used to design and build
the home need to be shared and common. A goal of
this home is to be a national model of the greenest
self-sufficient design and construction available. The
Commons is part of the Living Building Challenge.
The Living Building Challenge is an initiative program
developed by the Cascadia Region Green Building
Council, which is the Northwest chapter of the U.S.
Green Building Council. The purpose of the Living
Building Challenge is to force architectural design and
construction beyond the scope outlined in the highest
LEED for Homes standard. The homes built in this
program are tested for performance and must meet
specific outcomes to be qualified. The green features
found in the Commons are described below.
NET-ZERO ENERGY
The home, with the help of a photovoltaic (PV) solar
array is classified as net-zero energy, which means that
the home generates as much or more energy than the
occupants consume through the course of a year. To
accomplish this, the house is grid inter-tied, which means
that when the solar array is producing more energy than
is needed, the energy is fed into the power grid and
when the solar array is not producing enough, the home
pulls power back from the grid.
SUPER INSULATED
The building envelope can be the most important
consideration when designing a sustainable structure,
because the heating and cooling of a building are
the largest energy loads. The walls for the Commons
are made using a double-steel stud construction
technique with an overall thickness of 12", and
insulated with AirKrete cementitious foam insulation,
blown-in cellulose, and clad in fiber-cement paneling.
Cementitious foam insulation is an effective air barrier,
nontoxic, not a petroleum product, and not susceptible to
moisture damage. Blown-in cellulose is a waste product,
nontoxic, and low in cost. Fiber-cement cladding is a
highly durable and nontoxic material that acts as a skin
for the building envelope.
life of the building, which is an important aspect of
sustainability.
PASSIVE SOLAR DESIGN
The Commons is oriented with its longest and tallest
face towards the south and the southern walls are
largely glass in order to gain as much warmth from the
winter sun as possible. The floors within the sunspace
and greenhouse are earthen, which have high thermal
mass for storing solar energy. Passive solar systems are
discussed further in this chapter.
NET-ZERO WATER AND RAINWATER
CATCHMENT
Net-zero water means that a home collects or generates
as much or more water than the occupants consume
through the course of a year. All water used in the
Commons, including potable water, is gathered from
rainwater falling on the roof and stored in a cistern. This
system removes the dependence on municipal water
systems and increases awareness of usage, because the
occupants can consume only the amount of water that
has been supplied naturally. A cistern is a receptacle
for holding water or other liquid, especially a tank for
catching and storing rainwater. This is also referred to
as a rainwater catchment system. Rainwater catchment
systems are described further in Chapter 20.
GREEN ROOF
Incorporated in the roof design is a green roof, which
reduces the urban heat island effect and potentially
tempers heating and cooling loads in the building.
Also known as a rooftop garden, a green roof is
planted over an existing roof structure to help reduce
building temperatures, filter pollution, and lessen
stormwater runoff, thereby lessening the load on the
city wastewater system. The urban heat island effect
means that city areas are warmer than suburbs or rural
areas due to less vegetation, more land coverage, and
other infrastructure.
SOLAR HOT WATER
In addition to photovoltaic panels for electricity, the
Commons has solar hot water panels to offset the water
heating loads and provide warm water to radiant wall
heaters. Solar hot water systems are described in Chapter 20.
CLEAR SPAN STRUCTURE
COMPOSTING TOILETS AND GRAY
WATER RECLAMATION
The Commons is constructed so all interior walls are
non-load-bearing, allowing for easier reconfiguration
of the space in the future, which can extend the useful
The Commons has waterless composting toilets, which
lower overall water requirements for the house. By using
a composting system, the home can be disconnected
GOING
GREEN
249
The Ultimate Urban Green Home (Continued)
from the municipal sewer system. Gray water processing
has just recently been approved in the state of Oregon,
for use in flushing toilets and irrigation. Designers are
working with city and state officials to process and treat
the gray water back to potable standards on-site. A goal
of the Commons is to become an example project by
putting the gray water through constructed wetlands in
the greenhouse, onto the green roof, and then allowing
it to be filtered back into the cistern for potable water.
Confirm the possibility of gray water reclamation with
regulations in your area. If the designers are unable to
obtain the proper permits to process gray water on-site,
the home will be built with rough plumbing in order to
implement a gray water reuse system when permits are
available. Gray water is wastewater from clothes washing
machines, showers, bathtubs, hand washing, lavatories,
and sinks. By removing toilets from the municipal sewer
system, the home reduces the load on the system. Rough
plumbing is the plumbing system found beyond the
location where sinks, showers, tubs, toilets, and related
fixtures connect. Composting toilets also allow for the
compost waste product to be used as fertilizer for the
ornamental landscaping and soil remediation around
the house. Composting toilets are described further in
Chapter 20.
EARTHEN FLOORS
Earthen floors are a green building technology that
combines the mixture of sand, clay soil, and fibers that
are poured in place and sealed with linseed oils and
waxes to make durable washable surfaces. The finished
surface is more comfortable to walk on than concrete
or tile, and can be easily repaired in case of damage.
The earthen floor system allows sunlight to enter the
FIGURE 1217 A rendering of the Commons with numbers
identifying sustainable features described in the text. Courtesy res
communis, www.rescommunis.org.
structure and be absorbed. The stored heat helps warm
the living space.
The features of the Commons are shown in Figure 12-17
with the exterior rendering, and Figure 12-18 providing
the upper-level and lower-level floor plans. The numbers
identified on the exterior rendering and floor plans are
outlined in the following:
1. Green Roof—The green roof reduces the urban heat
island effect, tempers heating and cooling loads, and
slows stormwater runoff.
2. Rainwater Catchment—All water used is gathered from
rainwater falling on the roof and stored in a cistern.
3. Translucent Movable Roof—This portion of the roof
is transparent to allow light to filter through, but
FIGURE 1218 (A) The main floor and (B) the second floor of the Commons with numbers identifying sustainable features described
in the text. Courtesy res communis, www.rescommunis.org.
250
GOING
GREEN
The Ultimate Urban Green Home (Continued)
keeps the courtyard below mostly dry and allows for
its use during rainy weather.
4. Movable Walls—Large glass roll-up doors on the
greenhouse and sunspace blur the boundary
between indoors and out.
5. Exterior Walls—The walls for the Commons are
made using 12"-thick double steel stud construction,
insulated with AirKrete and clad in fiber-cement
paneling.
6. Energy Source—All power used in the home is
provided by a roof-mounted solar array. The home
is net-zero energy.
7. Subterranean Shop and Garden—A subterranean
shop allows the occupants to maintain a backyard
space for a garden and fruit trees. Being underground,
sound created from tools and activities are deadened,
reducing noise pollution.
8. Appliances—The custom refrigerator is superinsulated with a new vacuum insulation allowing
R-50 in 2 inches. A washing machine that spins most
of the water out, in conjunction with a clothesline,
eliminates the need for a clothes drier. A built-in
central vacuum cleaner results in cleaner air,
exhausting dust and particulates to the exterior.
9. Composting Toilet—Waterless composting toilets
lower overall water requirements for the house. A
custom bidet is installed on the toilet to prevent the
need for toilet paper.
10. Sunspace and Greenhouse—The sunspace and
greenhouse capture solar heat and store it in the
thermal mass of the earthen floors. The sunspace
also acts as a flex space with its roll-up glass doors
allowing it to bridge the gap between the kitchen
and the outdoors in milder times of the year.
The indoor greenhouse allows the occupants to
supplement their diet with fresh, home grown
foods. The plants condition the air by removing
pollutants that enter the house from outside and
from off-gassing electronics. Plants have also been
shown to increase the productivity and happiness
of occupants. In addition to offering a place to grow
plants, the greenhouse also has a large quantity of
glass to capture solar heat gain from the sun, which
can be drawn into the living spaces.
11. Interior Walls—Many components within the house,
including the interior walls, are constructed from
reused materials such as wood and glass from the
previous building on the site.
12. Floors (Office)—High-traffic areas and circulation
paths, such as those in the office, are made of an
earth-based “concrete” because of its durability.
Areas where the occupants spend more time
standing are clad in reused wood to be warmer and
more comfortable underfoot.
13. Dual Density—The house is designed with two
master bedrooms in order to increase density and
accommodate two families. This increased density
fosters community and mutual aid, and allows the
sharing of resources, which lowers the overall impact
of all involved.
14. Courtyard—The courtyard provides a transition
between the home and backyard and is a buffer
between the two master bedrooms.
Additional features found in the Commons are
discussed below.
Windows
The windows in the structure are oriented to the sun
and have a low U-value, but in some cases, the U-value
is traded for a higher solar heat gain coefficient (SHGC)
allowing for a greater harvest of the sun’s energy.
Daylighting was also a priority in design; all living
spaces have at least two walls with windows in order
to balance the light.
Energy Recovery Ventilator
An energy recovery ventilator (ERV) allows for an airtight
house, and provides energy efficiency because the stale
outgoing air is passed through a heat exchanger, where
the outgoing air exchanges its conditioned state (hot
or cold) with the incoming fresh air, conserving energy.
ERVs also allow for humidity levels to be monitored and
controlled.
Wings
Wings hide the conduit for the photovoltaic system, solar
hot water tubes, and rainwater conveyance.
Airlock
The two successive doors at the main entrance function
as an airlock.
Flex Space
This space has a multitude of capacities, ranging from an
entertainment space, an art space, or a guest bedroom.
Earthen Floors
Earthen floors have been specified for all rooms, with the
exception of the kitchen and bedrooms. Earthen floors
have little to no embodied energy, are made from local
materials, and are pleasant and warm underfoot.
Chapter 12: Conservation and Environmental Design and Construction
in every state. Common examples are abandoned gas
stations and dry cleaners, railroad properties, factories,
and closed military bases. Brownfields can also include
ADDITIONAL RESOURCES
www.airkrete.com
www.ase.org
www.ases.org
www.usabiomass.org
www.certainteed.com
www.pdxlivingbuilding
www.dap.com
www.earthadvantage.com
www.energystar.gov
www.envirohome.chba.ca
www.epa.gov
www.epa.gov/greenpower
www.epa.gov/iaq
properties that are under-utilized for various socioeconomic reasons, such as abandonment, obsolescence, tax
delinquency, and blight.
See CD for more information
The following Web sites can be used as a resource to
help you keep current with changes in environmental
design and construction.
Address
251
Company, Product,
or Service
AirKrete—Manufacturer of
cementitious foam insulation
Alliance to Save Energy
American Solar Energy
Society
Biopower
CertainTeed (insulation)
The Commons—One of
the nation’s first living
buildings
Dap caulking
Earth Advantage program
Energy Star
EnviroHome Initiative,
Canadian Home Builders’
Association
Environmental Protection
Agency
EPA—Green Power
Partnership
EPA—Indoor air quality
www.usgbc.org/leed
www.usgbc.org/leed/homes
www.davelennox.com
Leadership in Energy and
Environmental Design
(LEED) Green Building
Rating System
The LEED for Homes
program
Lennox Industries, Inc.
www.nahbrc.org/greenguidelines
NAHB Green Building
Guidelines
www.brownfieldassociation.org
www.nahbrc.org/gbstandard
www.osisealants.com
www.rescommunis.org
www.seia.org
www.doe.gov
National Brownfield
Association
National Green Building
Standard
OSI Sealants, Inc.
res communis design
Solar Energy Industries
Association
U.S. Department of Energy
www.windpoweringamerica.gov
www.epa.gov
www.usgbc.org
Conservation and Environmental
Design and Construction Test
U.S. Department of Energy,
Wind and Hydropower
Technology Program, and
wind resource maps
U.S. Environmental
Protection Agency (EPA)
U.S. Green Building Council
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 12 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 12–1 List three reasons why energy-efficient
construction techniques are becoming important.
Question 12–2 Describe at least one factor that may be
a disadvantage of energy-efficient construction.
Question 12–3 What is the primary goal of energyefficient design and construction?
Question 12–4 Identify at least one goal of conservation
design.
252
Question 12–5 Why is it possible to use energy-efficient
design in any architectural style?
Question 12–6 Why is it possible to implement some
energy-efficient design in every new home?
Question 12–7 List two site factors that contribute to
energy-efficient design.
Question 12–8 List two room layout factors that
contribute to energy-efficient design.
Question 12–9 List two window placement factors that
contribute to energy-efficient design.
Question 12–10 What are the two basic residential and
commercial uses for solar heat?
Question 12–11 Describe passive and active solar
heating.
Question 12–12 List and describe three factors that
influence a good solar design.
Question 12–13 Discuss the concept of right to light.
Question 12–14 Define each of the following
solar systems and make a sketch to show how it
functions:
a. South-facing glass
b. Clerestory windows
c. Thermal storage wall
d. Roof pond
e. Solarium
Question 12–15 Define solar collector.
Architectural Drafting and Design
STUDENT CD QUESTIONS
The following questions are based on the Student CD–related
content found in this chapter. These questions are optional
depending on your course objectives.
Question CD 12–1 List two factors that influence
a reduction in air infiltration into a structure.
Refer to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES.
Question CD 12–2 Identify at least two goals of an
energy-efficient construction system. Refer to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–3 List three general materials for
energy-efficient construction. Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–4 What is caulking? Where is it
typically used? Refer to the Student CD: ENERGYEFFICIENT CONSTRUCTION PRACTICES.
Question CD 12–5 What is the recommended thickness
for a vapor barrier in a crawl space? Refer to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–6 Refer to the Student CD: ENERGYEFFICIENT CONSTRUCTION PRACTICES. List the
typical R-value for the following uses based on the
DOE recommendations:
Question 12–16 What are solar architectural concrete
products, and how do they function?
a. Flat ceilings
Question 12–17 Describe three applications of
geothermal heating and cooling systems.
c. Walls
Question 12–18 Describe the function of photovoltaic
cells.
Question 12–19 What is the recommended overhang for
36° north latitude?
Question 12–20 What is the recommended overhang for
48° north latitude?
Question 12–21 Define direct solar gain.
Question 12–22 Give two advantages of wind power
generation.
Question 12–23 List at least 10 features and/or
products that can be considered for designing a
healthy home.
Question 12–24 What are sustainable buildings?
Question 12–25 Describe the green building concept.
Question 12–26 Define brownfields.
Question 12–27 Define green power.
Question 12–28 Briefly describe the Energy Star
program.
b. Floors
Question CD 12–7 Describe and show sketches
demonstrating the envelope design. Refer to the
Student CD: ENVELOPE DESIGN.
Question CD 12–8 What are radiant barriers, and
what is their function? Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–9 Describe the function of insulation.
Refer to this chapter, to Chapter 9, and to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–10 List at least four items that
influence how much insulation a home should
have. Refer to this chapter, to Chapter 9, and to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–11 What does R-value measure? Refer
to this chapter, to Chapter 9, and to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Chapter 12: Conservation and Environmental Design and Construction
253
Question CD 12–12 The ability of material to slow
heat transfer is called what? Refer to this chapter,
to Chapter 9, and to the Student CD: ENERGYEFFICIENT CONSTRUCTION PRACTICES.
Question CD 12–26 What is the class of a window
that has a U-value of 0.40? Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–13 What does the “R” in R-value
mean? Refer to this chapter, to Chapter 9, and to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–27 Identify a foam-in-place insulation
material that gives high R-values and airtight seals and
provides low toxicity. Refer to this chapter, to Chapter
9, and to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES.
Question CD 12–14 Briefly describe loose-fill
insulation. Refer to the Student CD: ENERGYEFFICIENT CONSTRUCTION PRACTICES.
Question CD 12–15 Give at least one advantage
of loose-fill insulation. Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–28 Refer to this chapter, to Chapter
9, and to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES. Give the insulation
code for the following building components based on
sample energy code requirements:
a. Walls
Question CD 12–16 Provide a brief description of
batts and blanket insulation. Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
b. Flat ceilings
Question CD 12–17 Why is careful installation of
batts and blanket insulation important? Refer to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
e. Basement walls
Question CD 12–18 Give at least three advantages of
rigid insulation. Refer to the Student CD: ENERGYEFFICIENT CONSTRUCTION PRACTICES.
Question CD 12–19 Identify at least three places where
rigid insulation is commonly used. Refer to the
Student CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Question CD 12–20 Give at least two advantages of
foam-in-place insulation. Refer to the Student CD:
ENERGY-EFFICIENT CONSTRUCTION PRACTICES.
c. Vaulted ceilings
d. Under floor
f. Slab floor edge
g. Forced-air ducts
h. Windows
i. Front entry door
j. Other exterior doors
k. Skylights
PROBLEMS
Write a report of 250 or fewer words on one or more of the
following topics:
Question CD 12–21 Name the only insulation that
can be used in closed cavities. Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Problem 12–1 U.S. Green Building Council (USGBC)
Question CD 12–22 What is the R-value range per
inch of thickness for fiberglass batts and blanket
insulation? Refer to this chapter, to Chapter 9,
and to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES.
Problem 12–4 Energy Star
Question CD 12–23 Describe insulated windows.
Refer to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES.
Problem 12–7 Energy-efficient construction, insulated
windows
Question CD 12–24 What is the advantage of using
argon gas in insulated windows? Refer to the Student
CD: ENERGY-EFFICIENT CONSTRUCTION
PRACTICES.
Problem 12–9 Thermal storage walls
Question CD 12–25 What is low-e glass and what does
it do? Refer to the Student CD: ENERGY-EFFICIENT
CONSTRUCTION PRACTICES.
Problem 12–2 Leadership in Energy and Environmental
Design (LEED)
Problem 12–3 Green Building Rating System
Problem 12–5 Energy-efficient construction, caulking,
vapor retarders, radiant barriers
Problem 12–6 Energy-efficient construction, insulation
Problem 12–8 Solar energy design
Problem 12–10 Envelope design (Refer to the Student
CD: ENVELOPE DESIGN.)
Problem 12–11 Active solar systems
Problem 12–12 Geothermal systems
Problem 12–13 Wind energy, including local projects
254
Architectural Drafting and Design
Problem 12–14 Healthy design and construction
Problem 12–23 Roof ponds
Problem 12–15 Brownfields
Problem 12–24 Green roof
Problem 12–16 Green power
Problem 12–25 Solarium
Problem 12–17 The Commons
Problem 12–26 Solar collectors and storage
Problem 12–18 NAHB Green Building Guidelines
Problem 12–27 Solar architectural concrete products
Problem 12–19 Indoor air quality
Problem 12–28 Photovoltaic modules
Problem 12–20 The LEED for Homes program
Problem 12–29 Hydroelectric power
Problem 12–21 National Green Building Standard
Problem 12–30 Evaluate and describe your own principles
surrounding the energy-efficient design and construction
applications discovered in this chapter.
Problem 12–22 EnviroHome Initiative, Canadian Home
Builders’ Association
www.kevinmillerphoto.com
SECTION 3
Site Planning
This page intentionally left blank
CHAPTER 13
Site Orientation
I
N
T
R
O
D
U
C
T
I
O
N
Site orientation is the placement of a structure on the property
with certain environmental and physical factors taken into consideration. Site orientation is one of the preliminary factors that
an architect or designer takes into consideration when beginning the design process. The specific needs of the occupants,
such as individual habits, perceptions, and aesthetic values, are
important and need to be considered. When designing the
home or business, the designer or architect has the responsibility of combining the values of the owner with other factors that
influence the location of the structure. In some cases site orientation is predetermined. For example, in a residential subdivision
where all lots are 50' × 100' (1524 × 3048 m), the street frontage
often dictates the front of the house. The property line setback
requirements do not allow much flexibility. Setback is the minimum distance required between the structure and the property
line. In such a case, site planning has a minimal influence on the
design. This chapter presents factors that can influence site orientation, such as terrain, view, sunlight, wind, and sound.
TERRAIN ORIENTATION
The terrain is the characteristic of the land on which the
proposed structure shall be placed. Terrain affects the
type of structure to be built. A level construction site is
a natural location for a single-level or two-story home.
Some landscape techniques on a level site can allow for
alternatives.
For example, the excavation material plus extra topsoil could be used to construct an earth berm, which is
a mound or built-up area. The advantage of the berm
is to help reduce the apparent height of a second story
or to add earth insulation to part of the structure (see
Figure 13-1). Construction on any site requires that a
slope be graded away from the house. This is to help
ensure that normal rainwater drains away.
Sloped sites are a natural location for multilevel or
daylight basement homes. A single-level home is a poor
choice on a sloped site because of the extra construction
cost for excavation or building up the foundation (see
Figure 13-2). Some builders have taken advantage of very
steep construction sites by designing homes on stilts. This
requires careful geological and structural engineering to
ensure safe construction. Figure 13-3 shows how terrain
can influence housing types. Subterranean construction
has gained popularity, and provides some economical
advantages in energy consumption. The terrain of the
site is an important factor to consider in the implementation of subterranean designs (see Figure 13-4).
VIEW ORIENTATION
In many situations, future home owners purchase a
building site before they begin the home design. In a
large number of these cases, the people are buying a
view. The view may be of mountains, city lights, a lake,
a river, the ocean, or even a golf course. These view
sites are usually more expensive than comparable sites
without a view. The architect’s obligation to the client in
this situation is to provide a home design that optimizes
the view. Actually, it is best to provide an environment
that allows the occupants to feel as though they are part
of the view. Figure 13-5 shows a dramatic example of a
view as part of the total environment.
GRADE
ONE-LEVEL HOUSE, LEVEL SITE
MAIN FLOOR
GRADE
BASEMENT FLOOR
LANDSCAPE BERM, LEVEL SITE
FIGURE 131 Level site.
257
258
Architectural Drafting and Design
MAIN FLOOR
ORIGINAL GRADE
SECOND FLOOR
LOWER FLOOR
GRADE
EXCAVATION
MULTILEVEL, SLOPED SITE
EXCESS EXCAVATION
FOUNDATION AND FRAMING
MAIN FLOOR
GRADE
BASEMENT FLOOR
WASTED
SPACE
EXCESS FOUNDATION
AND FRAMING
DAYLIGHT BASEMENT, SLOPED SITE
ONE-LEVEL HOUSE, SLOPED SITE
FIGURE 132 Sloped sites.
TWO STORY
ONE LEVEL
TWO LEVEL
APPROPRIATE ON FLAT
SITE WHERE SPACE IS
LIMITED.
ON SLAB OR CRAWL
SPACE SUITS FLAT SITE.
FULL-STORY DROP IN SITE.
MULTILEVEL
TRI-LEVEL
BI-LEVEL
APPROPRIATE FOR
SLOPING SITE.
SUITABLE FOR SLOPED
SITE.
SUITABLE FOR FLAT SITE.
ECONOMIC USE OF
FOUNDATION WALL.
FIGURE 133 Terrain determines housing types.
Chapter 13: Site Orientation
GRADE
259
WINTER PATH
GLASS WALL,
NATURAL LIGHT,
AND VENTILATION
SUMMER PATH
SPRING AND
AUTUMN PATH
SOLAR
ORIENTATION
SW SET
WINTER
S
SUNSET
W
UNDERGROUND
STRUCTURE
SUBTERRANEAN, SLOPED SITE
FIGURE 134 Subterranean construction site.
NW SET
SUMMER
SE RISE
WINTER
E
SUNRISE
NE RISE
SUMMER
N
FIGURE 136 Southern exposure.
When a site has southern exposure that allows solar
orientation, a little basic astronomy can contribute to
proper placement of the structure. Figure 13-6 shows
how a southern orientation relative to the sun’s path
provides the maximum solar exposure.
Establishing South
FIGURE 135 View orientation. Courtesy Pella Windows and Doors.
View orientation can conflict with the advantages of
other orientation factors such as solar or wind orientation. When a client pays a substantial amount to purchase a view site, such a trade-off may be necessary.
When the view dictates that a large glass surface face
a wind-exposed non-solar orientation, some energysaving alternatives should be considered, such as
providing as much solar-related glass as possible. Use
small window surfaces in other areas to help minimize
heat loss. Use triple-glazed windows in the exposed
view surface as well as in the rest of the structure if
economically possible. Insulate and seal to stop air
leakage.
SOLAR ORIENTATION
The sun is an important factor in home orientation.
Sites with a solar orientation allow for excellent exposure to the sun. There should not be obstacles such
as tall buildings, evergreen trees, or hills that have the
potential to block the sun. Generally, a site located on a
south slope has these characteristics.
A perfect solar site allows the structure to have unobstructed southern exposure. When a site has this
potential, true south should be determined. This determination should be established in the preliminary planning stages. Other factors that contribute to orientation,
such as view, can also be taken into consideration at this
time. If view orientation requires a structure be turned
slightly away from the south, it is possible that the solar
potential will not be significantly reduced.
True south is determined by a line from the North
Pole to the South Pole. When a compass is used to
establish north–south, the compass points to magnetic north. Magnetic north is not the same as true
north. True north is the same as geographic north,
which is the North Pole. The difference between true
north and magnetic north is known as the magnetic
declination. Figure 13-7 shows the compass relationship between true north–south and magnetic
north. Magnetic declination differs between locations.
Figure 13-8 shows a map with lines that represent
the magnetic declination at different locations throughout the United States.
A magnetic declination of 18° east, which occurs in
northern California, means that the compass needle
points 18° to the east of true north, or 18° to the west of
260
Architectural Drafting and Design
TRUE
NORTH
MAGNETIC
NORTH
shows how the east–west street orientation can provide
the maximum solar potential. If the client loves trees
but also wants solar orientation, consider a site where
the home could be situated so southern exposure can be
achieved with coniferous trees to the north and deciduous trees on the south side. The coniferous trees can
effectively block wind without interfering with the solar
orientation. The deciduous trees provide shade from
the hot summer sun. In the winter, when these trees
have lost their leaves, the winter sun exposure is not
substantially reduced. Figure 13-10 shows a potential
solar site with trees.
WIND ORIENTATION
MAGNETIC
DECLINATION
TRUE
SOUTH
FIGURE 137 Magnetic declination.
true south. In this location, as you face toward magnetic
south, true south is 18° to the left.
Solar Site–Planning Tools
Instruments are available that calculate solar access
and demonstrate shading patterns for any given site
throughout the year. Solar access refers to the availability of direct sunlight to a structure or construction site.
Some instruments provide accurate readings for
the entire year at any time of day, in clear or cloudy
weather.
Solar Site Location
A solar site in a rural or suburban location where there
may be plenty of space to take advantage of a southern
solar exposure allows the designer a great deal of flexibility. Some other factors, however, can be considered
when selecting an urban solar site. Select a site where
zoning restrictions have maximum height requirements. This prevents future neighborhood development from blocking the sun from an otherwise good
solar orientation. Avoid a site where large coniferous
trees hinder the full potential of the sun exposure. Sites
that have streets running east–west and lots 50' × 100'
(1524 × 3048 m) provide fairly limited orientation
potential. Adjacent homes can easily block the sun
unless southern exposure is possible. Figure 13-9
The term prevailing winds refers to the direction from
which the wind most frequently blows in a given area
of the country. For example, if the prevailing winds
are said to be southwesterly, that means the winds in
the area generally flow from the southwest. There are
some locations that may have southwesterly prevailing winds, but during certain times of the year, severe
winds can blow from the northeast. The factors that
influence these particular conditions can be mountains,
large bodies of water, valleys, canyons, or river basins.
The prevailing winds in the United States are from west
to east, although some areas have wind patterns that
differ from this because of geological and environmental
factors.
Wind conditions should be taken into consideration
in the orientation of a home or business. In many cases,
different aspects of site orientation may present a conflict. For example, the best solar orientation may be in
conflict with the best wind orientation. The best view
may be out over the ocean, but the winter winds may
also come from that direction.
One of the factors used to evaluate orientation can
outweigh another. Personal judgment may be the final
ruling factor. A good combination can be achieved if
careful planning is used to take all of the environmental
factors into consideration.
Site Location
Wind conditions that influence site location can be
found in almanacs, in the local library, and on the
Internet. Look for subjects such as climate, microclimate, prevailing winds, and wind conditions.
Evaluate the direction of the prevailing winds in an
area by calling the local weather bureau, by discussing it
with local residents, or by searching the Internet. Select
an area where winter winds are at a minimum or where
there is protection from these winds. Within a 25-mile
Chapter 13: Site Orientation
FIGURE 138 U.S. magnetic declination grid map. Courtesy National Geophysical Data
Center (NGDC).
261
262
Architectural Drafting and Design
GOOD VIEW
UNPROTECTED FROM WINDS
N
PROTECTED
WINDS
PROTECTION BEHIND A HILL
EAST–WEST STREET
PROTECTED
WINDS
PROTECTION BEHIND A FOREST
FIGURE 139 East–west street orientation.
FIGURE 1311 Locations protected from wind.
(40-km) radius of a given area, wind can be more of a
problem in certain locations than it is in others. A hill,
mountain, or forest can protect the building site from
general wind conditions. Figure 13-11 shows some
examples of site locations that may be protected from
prevailing winds.
It can be very difficult to avoid all the negative
effects of winds in a given location. When a site has
been selected and wind continues to be a concern,
construction or landscaping techniques can contribute
to a satisfactory environment. A subterranean structure
may totally reduce the effects of wind. Underground
or partial underground homes, when placed with the
below-grade portion against the wind, can create substantial wind control, as seen in Figure 13-12.
When subterranean housing is not an option, some
other techniques can be used. Building the structure
partly into the ground with a basement or using berming can be a successful alternative. Proper foundation
drainage is a factor to consider when these methods
are used. Figure 13-13 shows how wind protection can
be achieved with proper use of the earth. Landscaping
can also make an effective break between the cold
winter wind and the home site. Coniferous trees or
EXPOSED
SURFACE
NORTH
SOUTH
CONIFEROUS TREES
N
NORTH STREET
FIGURE 1312 Subterranean wind protection.
WIND
PROTECTED
PROTECTED
DECIDUOUS TREES
DAYLIGHT
BASEMENT
SPLIT ENTRY
EAST STREET
BERM
PROTECTED
BASEMENT
FIGURE 1310 Solar orientation with trees.
PROTECTED
BERMED FOUNDATION
FIGURE 1313 Wind protection using earth.
Chapter 13: Site Orientation
263
EVERGREEN HEDGE
COLD
WIND
WINDS
TWO STAGGERED ROWS
OF CONIFEROUS TREES
PROTECTED
SOUTH OR VIEW
FACING SIDE
2ND FL
BERM
1ST
FLOOR
DRIVE
FIGURE 1315 Roof slope with wind protection.
STREET
FIGURE 1314 Wind protection with landscaping.
other evergreen landscaping materials can provide an
excellent windbreak. These trees should be planted in
staggered rows. Two rows are a suggested minimum,
but three rows are better. Some hedge plants can be
put in one row to provide wind protection. Figure
13-14 shows how landscaping can protect a structure
from cold wind.
Room and construction design can also influence
wind protection. Place rooms that do not require a
great deal of glass for view or solar use on the north
side or the side toward severe winter winds. A garage,
even though unheated, is an insulator and can provide
an excellent break between cold winter winds and the
living areas of the home. Bedrooms with fairly small
windows can be placed to provide a barrier between
the wind and the rest of the home. A common method
of exterior construction design that helps deflect wind
is a long, sloping roof. A flat, two-story surface causes
a great deal of wind resistance. A better alternative is
achieved when a long, sloping roof is used to reduce
wind resistance, resulting in more energy-efficient
construction. Figure 13-15 shows how roof construction can effectively deflect prevailing winds.
Summer Cooling Winds
Summer winds may be mild and contribute to a more
comfortable living environment. Comfort can be
achieved through design for natural ventilation and
through landscape design. Effective natural ventilation can be achieved when a structure has openings
in opposite walls that allow for cross ventilation. In a
two- or multiple-story structure, the openings can be
effectively tied into the stairwells to provide for continuous ventilation. Figure 13-16 shows an example
of how good natural ventilation can be achieved. A
vacuum causes ventilation from the sheltered side of
the house, which forces air to suck through the house,
rather than wind pressure from the windward side of
the structure.
Landscaping can also help provide summer cooling.
The discussion of wind protection showed how coniferous trees can protect against cold winter winds. These
evergreen trees can also be used in conjunction with
deciduous trees to help funnel summer winds into the
home site and help provide natural summer cooling.
Fences or other buildings can also help create a wind
funnel. Deciduous trees serve a triple purpose. In the
summer they provide needed shade and act as a filter to
cool heated wind. In the winter they lose their leaves,
thus allowing the sun’s rays to help warm the house.
Figure 13-17 shows how an effective landscape plan can
be used to provide a total environment.
SUMMER
WIND
PATIO DOOR
WINDOW
ONE STORY
SUMMER
WIND
WINDOWS
WINDOW
PATIO DOOR
TWO STORY
FIGURE 1316 Natural ventilation.
264
Architectural Drafting and Design
HARSH WINTER
NORTHEASTERLY WIND
TWO ROWS
STAGGERED CONIFERS
EVERGREEN
HEDGE
STREET
DRIVE
ENTRY
DECIDUOUS TREES
EVERGREEN
HEDGE
A few landscaping designs can contribute to a quieter
living environment. Berms, trees, hedges, and fences
can all be helpful. Some landscape materials deflect
sounds, while others absorb sounds. The density of
the sound barrier has an influence on sound reduction,
although even a single hedge can help reduce a sound
problem. A mixture of materials can most effectively
reduce sound. Keep in mind that deciduous trees and
plants help reduce noise problems during the summer,
but they are poor sound insulation in the winter (see
Figure 13-18).
Trees can provide sound insulation. The greater the
width of the plantings for sound insulation, the better
the control. Trees planted in staggered rows provide
the best design. Figure 13-19 shows the plan view of
a site with sound barrier plants. Notice that the garage
is placed between the living areas of the home and
MILD SUMMER
SOUTHWESTERLY WIND
STREET
HEDGE
DRIVE
FIGURE 1317 Landscaping for wind control.
SOUND ORIENTATION
If your construction site is located in the country near
the great outdoors, sound orientation may not be a
concern. The sounds that you have are singing birds,
croaking frogs, chirping crickets, and possibly only a
few road noises. It is very difficult to eliminate road
sounds from many other locations. A site within a mile
of a major freeway can be plagued by excessive droning
road noise. A building site that is level with or slightly
below a road can have less noise than a site that is above
and overlooking the sound source.
DECIDUOUS OR
CONIFEROUS
TREES
TALL
EVERGREEN
HEDGE
FENCE
FIGURE 1318 Landscaping for sound insulation.
TWO ROWS
STAGGERED
EVERGREENS
BUSHES
PROPERTY LINE
GARAGE REDUCES SOUND
FIGURE 1319 Sound reduction: home and landscape plan.
TALL FIRS
SHORT
CEDARS
EVERGREEN
BUSHES
BERM
GOING
GREEN
265
Environmentally Sound Landscaping Practices
This Going Green feature introduces some landscaping
methods that can be used to reduce your ecological
footprint.
LANDSCAPE WITH LESS LAWN
When designing landscaping for a new home or if you
currently have a lawn, consider the following options:
• Reduce the size of your existing lawn or eliminate
it entirely depending on the needs of your family.
Smaller lawns generate less pollution by requiring less
water, fertilizer, and mowing.
• Choose organic fertilizers and quality composts to
help your lawn grow and build the soil.
• Use a manual push-mower for small lawns or try an
electric mower for larger areas.
• For areas of new lawn or when replacing an existing
one, choose grass mixes such as fescues or eco-mixes
that require less water than traditional ryegrass.
Figure 13-20 shows the before and after of a
landscaping project using environmentally sound
practices.
USING NATIVE AND DROUGHT-TOLERANT
PLANTS
Consider alternatives to landscaping plants that
demand regular and frequent watering, such as the
following options:
• Plant drought-tolerant plants in place of ornamental
plants that demand regular water throughout dry
summers. Drought-tolerant plants need watering
Before
the first year or two to get their roots established but
after that, their water consumption is reduced for an
accumulative savings.
• Use plants native to your region; they can easily adapt
to hot, dry summers. Some native plants even prefer
little water.
• Plant drought-tolerant shade trees in areas where
they shade roofs and streets from the hot sun to
reduce reflected heat and make these spaces more
comfortable.
• You can consult your local nursery, online sources, or
a landscape architect or designer to determine the
best native plants for your location.
PERMEABLE SURFACES AND ON-SITE
STORMWATER MANAGEMENT
Avoid concrete driveways, walkways or other
hardscape surfaces that do not allow rainwater to
run through them. Instead, consider the following
alternatives:
• Remove unnecessary hardscape; keep only what you
really need.
• If you are replacing old hardscaping or planning
new areas of hardscaping, try a new material such as
Drain Pave pavers, turf stones, permeable concrete or
asphalt, even gravel.
• Another way to ease the burden on city stormwater
drain systems is to divert downspouts to a “dry creek”
bed, bio-swale or pond area that fills and slowly
releases the water back into the soil during rainy
periods.
After
FIGURE 1320 Landscaping methods used to reduce your ecological footprint include less grass, native plants, permeable surfaces,
on-site stormwater management, and quality-zoned watering systems. Courtesy of DeSantis Landscapes. www.desantislandscapes.com.
266
GOING
GREEN
Environmentally Sound Landscaping Practices (Continued)
INSTALL A QUALITY IRRIGATION SYSTEM
Consider the following options when designing an
irrigation system for your landscaping:
• A properly installed irrigation system has separate
zones for lawn and shrub beds that should be further
broken down into those areas that have shade or full
sun exposure.
• Equipping your system with a rain sensor helps to
conserve water by automatically shutting off the
system when there is measurable rainfall.
• An irrigation system delivers your plants a consistent
supply of water, which helps establish and grow
healthy, strong plants.
the street to help reduce sound problems substantially.
Construction methods and materials can also reduce
sound transmission into the building. For example,
heavy construction materials such as masonry are effective. Some insulation products, discussed in Chapter
8 and Chapter 9, reduce sound transmission. Tripleglazed high-quality windows can also help reduce outside sound.
A number of factors influence site orientation. Solar
orientation may be important to one builder, but another
ADDITIONAL RESOURCES
• Use drip irrigation instead of spray heads where
appropriate.
• Water in the early mornings when evaporation rates
are low.
• Most established shrub plantings need to be
watered only two to three times per week in the
summer.
• Using a quality compost mulch on all shrub and tree
beds helps save water.
• Have an audit done with a Certified Irrigation Auditor
to learn the efficiency of your irrigation system.
home owner may consider view orientation as the main
priority. A perfect construction site has elements and
design features of each orientation. When a perfect site
is not available, the challenge for the designer or architect is to orient the structure to take the best advantage
of each potential design feature. As you have seen, it
is possible to achieve some elements of good orientation with excavation and landscaping techniques.
Always take advantage of natural conditions whenever
possible.
See CD for more information
The following Web sites can be used as a resource to
help you learn more about site orientation.
These Web site links are also provided on the Student
CD where you can select a link and go automatically to
the specified Web site.
Address
Company, Product,
or Service
www.desantislandscapes.com DeSantis Landscapes
www.australhomes.com/orientation
Principles of good home
orientation
www.hgtvpro.com
www.austinenergy.com
www.missourifamalies.gov
www.ehow.com
Search best practices for solar
site orientation
Search home orientation
Search housing
Search how to understand
your site’s solar orientation
Chapter 13: Site Orientation
267
See CD
for more
information
Site Orientation Test
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 13 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 13–13 List at least five advantages of
considering site orientation in the planning of a
home.
Question 13–14 Identify the type of homes that are
natural for a level site.
Question 13–15 Sloped sites are a natural for what type
of homes?
Question 13–1 Define site orientation.
Question 13–16 Why does construction on any
site require that a slope be graded away from the
structure?
Question 13–2 Describe in short, complete statements
five factors that influence site orientation.
Question 13–17 Give the compass orientation where the
sun rises and sets in the winter.
Question 13–3 Define magnetic declination.
Question 13–18 Give at least two examples of
construction methods and materials that can help
reduce sound transmission into a building.
Question 13–4 What is the magnetic declination of the
area where you live?
Question 13–5 Name and describe two types of
obstacles that can block the sun in an otherwise
good solar site.
Question 13–6 Describe how trees can be an asset in
solar orientation.
Question 13–7 What are prevailing winds?
Question 13–8 Name two features that can protect a
structure from wind.
Question 13–19 Define terrain.
Question 13–20 Why might view orientation be more
important than other orientation considerations?
PROBLEMS
Use a word processor to write a report of 250 or fewer
words on one or more of the following topics:
Question 13–9 Show in a sketch how landscaping can
be used for winter wind protection and summer
cooling.
Problem 13–1 Terrain orientation
Question 13–10 Show in a sketch how landscaping can
be an effective sound control.
Problem 13–4 Solar site–planning tools
Question 13–11 List at least two factors that must be
considered in subterranean construction.
Problem 13–6 Wind orientation
Question 13–12 List at least two disadvantages of a
two-story house on a narrow, treeless lot.
Problem 13–2 View orientation
Problem 13–3 Solar orientation
Problem 13–5 Solar site location
Problem 13–7 Summer cooling winds
Problem 13–8 Sound orientation
CHAPTER 14
Legal Descriptions and
Site Plan Requirements
R
O
D
U
C
T
I
O
N
Metes are measurements, and bounds are boundaries.
Metes and bounds are used to identify the perimeters of
any property. This is referred to as the metes and bounds
system. The metes are measured in feet, yards, rods (rd),
or surveyor’s chains (ch). There are 3' (914 mm) in
1 yard, 5.5 yards or 16.5' (5029 mm) in 1 rod, and 66'
(20 117 mm) in 1 surveyor’s chain. The boundaries can
be a street, fence, or river. Boundaries are also established as bearings, which are directions with reference
to 1 quadrant of the compass. There are 360° in a circle
or compass, and each quadrant has 90°. Degrees are
divided into minutes and seconds. There are 60 minutes
(60') in 1° and 60 seconds (60") in 1 minute. Bearings
are measured clockwise or counterclockwise from north
or south. For example, a reading of 45° from north to
west is labeled N 45° W (see Figure 14-1). If a bearing
reading requires great accuracy, fractions of a degree can
268
ºW
METES AND BOUNDS SYSTEM
45
This section deals with site plan characteristics and
requirements. A site is an area of land generally one
plot or construction lot in size. The term site is synonymous with plot and lot. A plat is a map of part of
a city or township showing some specific area, such
as a subdivision made up of several individual lots.
There are usually many sites or plots in a plat. Some
dictionary definitions, however, do not differentiate
between plot and plat.
There are three basic types of legal descriptions:
metes and bounds, rectangular survey system, and lot
and block.
N
N
Virtually every piece of property in the United States is described
for legal purposes. These descriptions are referred to as legal
descriptions. Every legal description is unique and cannot be
confused with any other property. Legal descriptions of properties are filed in local jurisdictions, generally county or parish
courthouses. Legal descriptions are public records and can be
reviewed at any time.
45º
60º
N6
0º
E
W
E
S 75
ºE
75º
30º
ºW
T
30
N
S
I
S
FIGURE 141 Bearings.
be used as needed. For example, S 30°20'10" E reads
from south 30 degrees 20 minutes 10 seconds to east.
The metes and bounds land survey begins with a
monument, known as the point of beginning (POB).
This point is a fixed location and in times past has been
a pile of rocks, a large tree, or an iron rod driven into
the ground. Figure 14-2 shows an example of a site plan
laid out using metes and bounds, along with the legal
description for the plot.
RECTANGULAR SURVEY SYSTEM
The states in an area of the United States starting
with the western boundary of Ohio to the Pacific
Ocean, and including some southeastern states and
Alaska, are described as public land states. Within
this area the U.S. Bureau of Land Management devised
a system for describing land known as the rectangular survey system.
Parallels of latitude and meridians of longitude were
used to establish areas known as great land surveys.
Chapter 14: Legal Descriptions and Site Plan Requirements
269
Townships
S
2'
44
S
°
56
N
'W
45
10
'
40
26
N
ING
SPR
°0
'W
WA
5' E
3° 1
S2
5'
114
TER
POB
.
RD
'E
N
°
48
30
77
8'
8.
The great land surveys are broken down into smaller
surveys known as townships and sections. The baselines and meridians are divided into blocks called
townships. Each township measures 6 miles square.
The townships are numbered by tiers running north–
south. The tier numbering system is established either
north or south of a principal baseline. For example, the
fourth tier south of the baseline is labeled Township
Number 4 South, abbreviated T. 4 S. Townships are
also numbered according to vertical meridians, known
as ranges. Ranges are established either east or west
of a principal meridian. The third range east of the
principal meridian is called Range Number 3 East,
abbreviated R. 3 E. Now combine T. 4 S. and R. 3 E. to
locate a township or a piece of land 6 miles by 6 miles
or a total of 36 square miles. Figure 14-4 shows the
township just described.
Sections
BEGINNING AT A POINT 1200’ NORTH 40˚ 0' WEST FROM THE
SOUTHEAST CORNER OF THE ASA STONE DONATION LAND
CLAIM NO. 49, THENCE NORTH 40˚ 0' WEST 1026’ TO A PIPE,
THENCE SOUTH 56˚ 45' WEST 442' TO CENTER OF ROAD, THENCE
SOUTH 23˚ 15' EAST 1145', THENCE NORTH 48˚ 30' EAST 778.8' TO
POINT-OF-BEGINNING.
FIGURE 142 Metes and bounds plot plan and legal description for the plot.
Lines of latitude, also called parallels, are imaginary parallel lines running east and west. Lines of
longitude, also called meridians, are imaginary lines
running north and south. The point of beginning
of each great land survey is where two basic reference lines cross. The lines of latitude, or parallels,
are termed the baselines, and the lines of longitude,
or meridians, are called principal meridians. There
are 31 sets of these lines in the continental United
States, with 5 in Alaska. At the beginning, the principal meridians were numbered, and the numbering system ended with the sixth principal meridian
passing through Nebraska, Kansas, and Oklahoma.
The remaining principal meridians were given local
names. The meridian through one of the last great
land surveys near the West Coast is named the
Willamette Meridian because of its location in the
Willamette Valley of Oregon. The principal meridians
and baselines of the great land surveys are shown in
Figure 14-3.
To further define the land within a township that is
6 miles square, the area is divided into units 1 mile
square, called sections. Sections in a township are
numbered from 1 to 36. Section 1 always begins in
the upper-right corner, and consecutive numbers
are arranged as shown in Figure 14-5. The legal
descriptions of land can be carried one stage further.
For example, Section 10 in the given township is
described as Sec. 10, T. 4 S., R. 3 E. This is an area of
land 1 mile square. Sections are divided into acres.
One acre equals 43,560 sq ft, and one section of land
contains 640 acres.
In addition to dividing sections into acres, sections
are divided into quarters, as shown in Figure 14-6.
The northeast one-quarter of Section 10 is a 160-acre
piece of land described as NE 1/4, Sec. 10, T. 4 S., R. 3 E.
When this section is keyed to a specific meridian, it
can be only one specific 160-acre area. The section can
be broken down further by dividing each quarter into
quarters, as shown in Figure 14-7. If the SW 1/4 of the
NE 1/4 of Section 10 were the desired property, then
you have 40 acres known as SW 1/4, NE 1/4, Sec. 10,
T. 4 S., R. 3 E. The complete rectangular system legal
description of a 2.5-acre piece of land in Section 10
reads: SW 1/4, SE 1/4, SE 1/4, SE 1/4 Sec. 10, T. 4 N.,
R. 8 W. of the San Bernardino Meridian, in the County
of Los Angeles, State of California (see Figure 14-8).
The rectangular survey system can be used to describe
very small properties by continuing to divide a section of
270
Architectural Drafting and Design
FIGURE 143 Principal meridians and baselines of the great land survey. Courtesy U.S. Bureau of Land Management.
Chapter 14: Legal Descriptions and Site Plan Requirements
N
N
NUMBERS
NUMBERS
RANGE
271
E
W
1 MILE SQUARE
TOWNSHIP
BASELINE
NW 1/4
NE 1/4
W
E
SW 1/4
SE 1/4
T. 4 S.
S
FIGURE 146 Section quarters.
S
PRINCIPAL MERIDIAN
R. 3 E.
T. 4 S., R. 3 E.
FIGURE 144 This graph shows a 36-square-mile township,
which results from combining Township Number 4 South (abbreviated T. 4 S.) and Range Number 3 East (abbreviated R. 3 E.).
a township. Often the township section’s legal description can be used to describe the location of the point
of beginning of a metes and bounds legal description,
especially when the surveyed land is an irregular site or
plot within the rectangular survey system.
LOT AND BLOCK SYSTEM
subdivided into individual building sites, the subdivision is established as a legal plat and recorded as such
in the local county records. The subdivision is given
a name and broken into blocks of lots. A subdivision
can have several blocks, each divided into a series of
lots. Each lot may be 50' × 100' (15240 × 30480 mm,
15.24 × 30.48 m), for example, depending on the
zoning requirements of the specific area. Figure 14-9
shows an example of a typical lot and block system.
A typical lot and block legal description might read:
LOT 14, BLOCK 12, LINCOLN PARK NO. 3, CITY
OF SALEM, STATE. This lot is the shaded area in
Figure 14-9.
The lot and block legal description system can result
from either the metes and bounds or the rectangular system. Generally, when a portion of land is
N
NW 1/4
NE 1/4
NE 1/4
NE 1/4
SW 1/4
NE 1/4
SE 1/4
NE 1/4
NW 1/4
N
1 MILE
SQUARE
W
6
5
4
3
2
1
7
8
9
10
11
12
18
17
16
15
14
13
6 MILES SQUARE
W
E
E
T. 4 S.
19
20
21
22
23
24
30
29
28
27
26
25
31
32
33
34
35
36
SW 1/4
SE 1/4
S
R. 3 E.
S
FIGURE 145 One township comprises 36 sections. Section
numbers 1 through 36 are always arranged as shown here.
FIGURE 147 Dividing a quarter section.
272
Architectural Drafting and Design
N
NW 1/4 NW 1/4
40 ACRES
SW 1/4 NW 1/4
40 ACRES
NE 1/4 NW 1/4
40 ACRES
N 1/2 NE 1/4
80 ACRES
W 1/2
SW 1/4
NE 1/4
20 AC
SE 1/4 NW 1/4
40 ACRES
E 1/2
SW 1/4
NE 1/4
20 AC
N 1/2 SE 1/4 NE 1/4
20 ACRES
S 1/2 SE 1/4 NE 1/4
20 ACRES
W
E
N 1/2 N 1/2 SE 1/4
40 ACRES
N 1/2 S 1/2 NE 1/4 SE 1/4
10 ACRES
S 1/2 S 1/2 NE 1/4 SE 1/4
10 ACRES
S 1/2 NW 1/4 SE 1/4
20 ACRES
SW 1/4
160 ACRES
SW 1/4 SE 1/4
40 ACRES
S
NW 1/4
SE 1/4
SE 1/4
10 AC
NE 1/4
SE 1/4
SE 1/4
10 AC
N 1/2 SE 1/4 SE 1/4
5 ACRES
SW 1/4
SE 1/4
SE 1/4
10 AC
SE 1/4 SE 1/4 SE 1/4 SE 1/4
2.5 ACRES
SW 1/4 SE 1/4 SE 1/4 SE 1/4
2.5 ACRES
FIGURE 148 Sample divisions of a section.
SITE PLAN REQUIREMENTS
A site plan, also known as a plot or lot plan, is a map
of a piece of land that can be used for any number of
purposes. Site plans can show a proposed construction
site for a specific property. Sites can show topography
with contour lines, or the numerical value of land elevations can be given at certain locations. Site plans are also
used to show how a construction site will be excavated
and are then known as grading plans. Site plans can be
drawn to serve any number of required functions, and
all have similar characteristics, which include showing
the following:
●
A legal description of the property based on a survey.
Property line bearings and directions.
● North arrow.
● Roads and easements.
● Utilities.
● Elevations.
● Map scale.
●
As stated earlier, plats are maps that are used to show
an area of a town or township. They show several or
many lots and can be used by a developer to show a
proposed subdivision of land.
TOPOGRAPHY
Topography is a physical description of land surface
showing its variation in elevation, known as relief, and
locating other features. Surface relief can be shown with
graphic symbols that use shading methods to accent the
character of land, or the differences in elevations can
be shown with contour lines. Site plans that require
surface relief identification generally use contour lines.
Contour lines connect points of equal elevation and
help show the general lay of the land.
A good way to visualize the meaning of contour lines
is to look at a lake or ocean shoreline. When the water is
high during the winter or at high tide, a high-water line
establishes a contour at that level. As the water recedes
during the summer or at low tide, a new lower-level
1200
1100
2
3
4
1900
12
2100
3300
2800
P
NIA
VA
YL
10
S
N
EN
1
11200
9 11300
3
9100
4
O
OP
D LO
10700
9000
5
9300
9200
I
11400
9400
1
2
I
8900 5
I
11100
7
11500
I
8
LWO
RN DR
ELKHO
SE
9500
4
N
1" = 100'
21–MAR–84
SE
CK 8
NO
SE
1
7200
1
7300
2
BUR
I
CT
6
I
12200
1
6
7000
1
23
8700
11600
I
2
N
BA
11700
5
21 3
12100
12300
4
7
19
7100
7500
4
7400
3
8600
22
6
7700
16
2
H DR
4800
12000
5000
4900
11800
11900
6900
2
7800
NDOA
2
5200
OO
5 7600
8
3
OP
D LO
A
SHEN
4
5100
LW
BUR
6800
790014
12
10
9
8500
5300
5
4
20
I
4700
1
5400
6700
8100
8400
14
6100
8200
11
8300
6600
6400
8000
5700
I
6
12
5900
4
6500
6200
13
6000
5800
I
2
11
10
5500
7
3
9
5600
8
2
6300
1
I
3
4600
1
3
2
2600
4500
E
NU
AVE
2300 4
2500
5
3
I
2400
4
600
9
6
I
4400
20 2700
14
500 10
7
2200
5
5
8
I
47TH CT
14
2000
100
700
8
I
46TH PLACE
1600
13
3400
4300
11
9
1800
I
19
10
1700
I I
6
7
I
4200
15
3200
2900
11
400
800
I
7
18
13
6
CE
PLA
4100
11
12
1500
200
12
CT
TH
16
3100
3000
8
300
13
46TH
17
4000
900
WAY SE
BABCOCK
9
1000
5
SEE MAP 7 2W 3280
1300
1
48
3900
1400
I
13
I
3500
12
I
3600
11
I
3700
10
273
II
3800
47TH AVE
Chapter 14: Legal Descriptions and Site Plan Requirements
9600
18 3
FIGURE 149 Part of a lot and block subdivision. Courtesy GLADS Program.
elevations, street elevation at a driveway, and the
elevation of the finished floor levels of the structure.
Additionally, in some applications, slope can be identified and labeled with an arrow showing the direction of the slope.
0
10
0
10
SLOPE
DOWN
GENTLE SLOPE
90
90
line is established. This new line represents another
contour. The high-water line goes all around the
lake at one level, and the low-water line goes all
around the lake at another level. These two lines
represent contours, or lines of equal elevation. The
vertical distance between contour lines is known
as contour interval. When the contour lines are
far apart, the contour interval shows relatively flat
or gently sloping land. When the contour lines are
close together, the contour interval shows land that is
much steeper. Contour lines are broken periodically,
and the numerical value of the contour elevation above
sea level is inserted. Figure 14-10 shows sample contour lines. Figure 14-11 shows a graphic example of
land relief in pictorial form and contour lines of the
same area.
Figure 14-12 shows a site with contour lines. Site
plans do not always require contour lines showing
topography. Verify the requirements with the local
building codes. In most instances the only contourrelated information required is property corner
SLOPE
DOWN
STEEP SLOPE
FIGURE 1410 Contour lines showing both gentle and steep
slopes.
274
Architectural Drafting and Design
be found at a local building office or building permit
department. Some agencies, for example, require that
the site plan be drawn on paper of a specific size, such
as 8 1/2 × 14". Typical site plan items include the
following:
PICTORIAL
26
260
0
275
20
20
0
0
20
0
10
CONTOUR LINES
FIGURE 1411 Land relief pictorial and contour lines. Courtesy
U.S. Department of the Interior, Geological Survey.
●
Site plan scale.
●
Legal description of the property.
●
Property line bearings and dimensions.
●
North arrow.
●
Existing and proposed roads.
●
Driveways, patios, walks, and parking areas.
●
Existing and proposed structures.
●
Public or private water supply.
●
Public or private sewage disposal.
●
Location of utilities.
●
Rain and footing drains, and storm sewers or
drainage.
●
Topography, including contour lines or land elevations at lot corners, street center line, driveways, and
floor elevations.
DRAWING SITE PLANS
Site plan requirements vary by jurisdiction, such as city,
county, or state. Some site plan elements are similar
throughout the country. Guidelines for site plans can
ELEVATIONS AT CORNERS
R=25.00' L=39.27'
N 88°6'14" W
66.90'
EL. 100'
S
105
EL. 118'
5
134.92'
N 88°6'14" W
95'
N 1°29'48" E
34
°
11 09'
2. 22
93 " W
'
INDEX
CONTOUR LINE
110
11
EL. 100'
INTERMEDIATE
CONTOUR LINE
EL. 111.2'
CONTOUR INTERVAL
FIGURE 1412 Site plan with contour lines.
Chapter 14: Legal Descriptions and Site Plan Requirements
275
219'
EL. 100.1'
98'
SLOPE
EL. 100.0'
SLO
225'
DRAIN FIELD
REPLACEMENT AREA
225'
25'
TEST PIT
N
I
'M
120
'
1000 GAL
SEPTIC TANK
30'
0
10
20'
WELL
EL. 103.4'
RAIN DRAIN
N
9TH STREET
PE
PROPOSED
3 BDR. HOUSE
EL.105.4'
WELL ON
ADJACENT LOT
60'
219'
DRIVEWAY
EL. 104.1'
LINDEN LANE
PLAN
SCALE 1" = 60'
FIGURE 1413 Recommended typical site plan layout.
●
Setbacks—the minimum distance from the property
lines to the front, rear, and sides of the structure.
●
Specific items on adjacent properties (may be
required).
●
Existing and proposed trees (may be required).
Figure 14-13 shows a site plan layout that is
used as an example at a local building department.
Figure 14-14 shows a basic site plan for a proposed
residential addition.
The method of sewage disposal is generally an
important item shown on a site plan drawing. There
are a number of alternative methods of sewage disposal, including public sewers and private systems.
Chapter 20 gives more details of sewage disposal
methods. The site plan representation of a public sewer
connection is shown in Figure 14-15. A private septic
sewage disposal system is shown on a site plan in
Figure 14-16.
GRADING PLAN FEATURES
Grading plans are construction drawings that generally show existing and proposed topography. The
outline of the structure can be shown with elevations at each building corner and the elevation given
for each floor level. Figure 14-17 shows a detailed
grading plan for a residential construction site.
Notice that the legend identifies symbols for existing
and finished contour lines. This example grading
276
Architectural Drafting and Design
60'–0"
N.E. 112th
8'–0" 11'–0"
122.50'
PROPOSED ADDITION
32'
54'–0"⫾
20'–0"
PROPOSED DECK
EXIST. SEPTIC TANK
66'–0"
15'–0"
EXIST.
GARAGE
123.34'
PLOT
1"
PLAN
20'–0"
LEGAL:
LOT #3
BLOCK F1
VIEW RIDGE
MULTNOMAH COUNTY
FIGURE 1414 Sample site plan showing existing home and proposed addition.
STRUCTURE
CL
S
MH
10'
S
S
1000 GAL.
SEPTIC TANK
STRUCTURE
STREET
5' MIN.
CL
STREET
FIGURE 1415 Plot plan showing a public sewer connection.
10'
125' MAX
FIGURE 1416 Plot plan showing a private septic sewage system.
Chapter 14: Legal Descriptions and Site Plan Requirements
277
A
PROJECT SITE
S. TWAIN DRIVE
96.55'
.
70.0
MU
TH
ST
70.0
75.0
BEAVE
BIS
N
75.0
RCREE
80.0
VICINITY MAP
98.69'
LEGEND
80.0
125.07'
EXISTING CONTOUR LINES
90.0
TW 98.0
BW 87.0
90.0
90.0
85.0
LOWER FLOOR 90.5
MAIN FLOOR 99.5
TW 100.0
BW 99.0
99.0
FINISH CONTOUR LINES
100
FINISH ELEVATION
100
FINISHED SLOPE (11/2:1 MAX)
90.0
99.0
RETAINING WALL
TOP OF WALL/BASE OF WALL
GARAGE 93.0
99.0
100
DRAINAGE SWALE (1% MIN.)
TW 100
BW 97
PROPERTY LINE
99.0
95.0
100
LEGAL DESCRIPTION
LOT 85, BLOCK 4, ANTHRACITE ESTATES,
100.0 LAWRENCE COUNTY, PENNSYLVANIA
100.0
104.52'
EXISTING SIDEWALK
EXISTING CURB
20'
A
10'
NEW CASTLE 4 MILES
D
NO SCALE
89
85.0
95.0
K ROA
16'
19'
CL S. TWAIN DRIVE
N
SCALE: 1" = 30'-0"
FIGURE 1417 Grading plan.
plan provides retaining walls and graded slopes to
accommodate a fairly level construction site from the
front of the structure to the extent of the rear yard.
The finished slope represents an embankment that
establishes the relationship of the proposed contour
to the existing contour. This example grading plan
also shows a proposed irrigation and landscaping
layout. A retaining wall is a concrete or masonry wall
supported at the top and bottom, designed to resist
soil loads.
Grading plan requirements can differ from one
location to the next. Some grading plans show a cross
section through the site at specified intervals or locations to evaluate the contour more fully. This cross
section is called a profile. A profile through the grading plan in Figure 14-17 is shown in Figure 14-18.
Drawing a grading plan and profile is explained in
Chapter 15.
SITE ANALYSIS PLAN
In areas or conditions where zoning and building permit applications require a design review, a site analysis
plan may be required. The site analysis provides the
basis for the proper design relationship of the proposed
development to the site and to adjacent properties.
The degree of detail of the site analysis is generally
appropriate to the scale of the proposed project. A site
analysis plan, shown in Figure 14-19, typically includes
the following:
●
A vicinity map showing the location of the property in relationship to adjacent properties, roads,
and utilities.
●
Site features, such as existing structures and plants
on the property and adjacent property.
●
Scale.
278
Architectural Drafting and Design
110
110
105
105
100
100
95
95
90
90
85
85
80
80
75
75
70
70
65
65
A
70.0
75.0
98.69'
99.0
99.0
96.55'
89
99.0
99.0
104.52'
EXISTING SIDEWALK
S. TWAIN DRIVE
A
80.0
85.0
100.0
TW 98.0
BW 87.0
90.0
10'
TW 100.0
BW 99.0
95.0
20'
A
CUTTINGPLANE
LINE
EXISTING SIDEWALK
110
105
100
95
90
85
80
75
70
65
MAIN FLOOR ELEVATION 99.5
LOWER FLOOR ELEVATION 90.5
FOUNDATION
110
105
100
95
90
85
80
75
70
65
B
FIGURE 1418 Constructing a profile from the grading plan in Figure 14-17. (A) Establish a horizontal grid with a
range of elevations found in the grading plan. (B) Project where each elevation crosses the cutting-plane line perpendicular to the corresponding elevation at the horizontal grid.
Chapter 14: Legal Descriptions and Site Plan Requirements
279
PREVAILING S.W.
WINDS
S.W./S./S.E.
SOLAR GAIN
ORIENTATION
EXISTING
WHITE OAKS
EXISTING LOMBARDY POPLARS
CROSS SECTION
SMALL ACTIVE
NEIGHBORHOOD
GROCERY STORE
POORLY MAINTAINED
COMMERCIAL BUILDINGS
PROVIDE ADEQUATE SCREENING
QUALITY M.F.
APARTMENT UNITS
TO NORTH OF SITE
PROVIDE CROSSWALK
RETAIN/SAVE ALL
EXISTING LARGE
WHITE OAKS SHOWN
SINGLE-FAMILY RESIDENCES
IN POOR SHAPE
GR
OU
ND
SL
OP
ES
BUS STOP – 2 MILES
TO DOWNTOWN
EXISTING GAS STATION (NEW)
OLD VICTORIAN
NEEDS REHAB.
STREET LIGHT
STOP SIGNS
WELL MARKED
PEDESTRIAN CROSS WALKS
S.W. WINDS
WI
SU
GENTLE SLOPING SITE
STEEP SLOPE ONLY IMMEDIATELY
ADJACENT TO TRORIAT CORRIDOR
NTER
M MER
EXISTING SEWAGE CAPACITY
ADEQUATE FOR NEW DEVELOPMENT
SITE ANALYSIS DIAGRAM
SCALE 1" = 60'-0"
LEGEND:
BUFFER STRIPS NEEDED
WATERLINE IN ROAD
SEWER LINES
TRANSIT ROUTE
BUS STOP
EXISTING TREES TO REMAIN
STOP SIGNS
PROPOSED SITE PROJECT POINTS OF ENTRY
EXISTING CONTOURS
FIGURE 1419 Site analysis plan. Courtesy Planning Department, Clackamas County, Oregon.
280
Architectural Drafting and Design
●
North arrow.
●
Property boundaries.
●
Slope shown by contour lines or cross sections, or
both.
●
Number identification of parcels, such as Parcel 1,
Parcel 2.
● Location of well or proposed well, or name of water
district.
● Type of sewage disposal (septic tank or public sanitary sewers). Name of sewer district.
● Zoning designation.
● Size of parcel(s) in square feet or acres.
● Slope of ground (arrows pointing downslope).
● Setbacks of all existing buildings, septic tanks, and
drainfields from new property lines.
● All utility and drainage easements.
● Any natural drainage channels. Indicate direction
of flow and whether drainage is seasonal or yearround.
● Map scale.
● Date.
● Building permit application number, if any.
●
Plan legend.
Traffic patterns.
● Solar site information if solar application is
intended.
● Pedestrian patterns.
●
SUBDIVISION PLANS
Local requirements for subdivisions should be confirmed because procedures vary, depending on local
guidelines and zoning rules.
Some areas have guidelines for minor subdivisions
with few sites that differ from major subdivisions with
many sites. The plat required for a minor subdivision
can include the following:
●
Legal description.
● Name, address, and telephone number of applicant.
● Parcel layout with dimensions.
● North arrow.
● All existing roads and road widths.
Figure 14-20 shows a typical subdivision of land
with three proposed parcels. The local planning agency
determines the measurements for a minor or major
subdivision.
A major subdivision can require more detailed plats
than a minor subdivision. Some of the items that can
SAMPLE
JOHN DOE
940 WARNER MILNE RD
OREGON CITY, OREGON 97045
655-8491
DATE:
ZONING:
ACREAGE:
SEWAGE:
WATER:
DECEMBER 3, 1999
RA-1
728 ACRES
SEPTIC TANK
PRIVATE WELL
203.87'
215'
202'
391'
LEGAL:
T 3 S, R 4 E, SEC. 24
TAX LOT 1000
T/L 200 T/L 300
T/L 400
471'
OWNER:
2.5 Ac.
2.78 Ac.
2.0 Ac.
Parcel I
Parcel II
670'
555'
Parcel III
EXISTING
HOUSE
'
217
SCALE: 1"=100'
EL
.
100'
E
SLOP
S.E
'
232
WELL
SITE
.2
IS
WE
RO
AD
60'
SOIL TEST HOLES
. NO
D
O. R
C
FIGURE 1420 Subdivision with three proposed lots. Courtesy Planning Department, Clackamas County, Oregon.
Chapter 14: Legal Descriptions and Site Plan Requirements
be included on the plat or in a separate document are
the following:
●
Name, address, and telephone number of the property owner, applicant, and engineer or surveyor.
● Source of water.
● Method of sewage disposal.
● Existing zoning.
● Proposed utilities.
● Calculations justifying the proposed density.
● Name of the major partitions or subdivision.
● Date the drawing was made.
● Legal description.
● North arrow.
● Vicinity sketch showing location of the subdivision.
● Identification of each lot or parcel and block by
number.
● Gross acreage of property being subdivided or
partitioned.
● Dimensions and acreage of each lot or parcel.
● Streets abutting the plat, including name, direction of
drainage, and approximate grade.
● Streets proposed, including names, approximate
grades, and radius of curves.
● Legal access to subdivision or partition other than
public road.
● Contour lines at 2' interval for slopes of 10% or less,
5' interval if slopes exceed 10%.
● Drainage channels, including width, depth, and
direction of flow.
● Location of existing and proposed easements.
● Location of all existing structures, driveways, and
pedestrian walkways.
● All areas to be offered for public dedication.
●
281
recreational areas, open spaces, schools, libraries,
churches, or convenient shopping facilities. Developers involved in these projects must pay particular
attention to the impact on local existing developments.
Generally, the plats for planned unit developments
must include all of the same information shown on a
subdivision plat, and also include these features:
●
Detailed vicinity map, as shown in Figure 14-22. A
vicinity map shows the development or construction
site in relation to the local area.
● Land use summary.
● Symbol legend.
● Special spaces such as recreational and open spaces
or other unique characteristics.
Figure 14-23 shows a typical planned unit development plan. These plans, like any proposed site plan,
may require changes before the final drawings are
approved for development.
There are several specific applications for a site
plan. The applied purpose of each is different,
although the characteristics of each type of site plan
are similar. Local districts have guidelines for the type
of plan required. Be sure to evaluate local guidelines
before preparing a site plan for a specific purpose.
To get a plot plan accepted, prepare it in strict accordance with the requirements.
A variety of plot plan–related templates and CADD
programs are available that can help make the preparation of these plans easier.
METRICS IN SITE PLANNING
The recommended metric values used in the design and
drafting of site plans based on surveying, excavating,
paving, and concrete construction are as follows:
Contiguous property under the same ownership, if any.
●
Boundaries of restricted areas, if any.
● Significant vegetative areas such as major wooded
areas or specimen trees.
Figure 14-21 shows an example of a small major
subdivision plat.
Surveying
Excavating
Paving
PLANNED UNIT DEVELOPMENT
A creative and flexible approach to land development
is a planned unit development. Planned unit developments may include such uses as residential areas,
Concrete
Quantity
Unity and Symbol
Length
meter (m) and kilometer (km)
Area
square meter (m2), hectare (ha),
and square kilometer (km2)
Plane angle
degree (°), minute ('), second ("),
and percent (%)
Length
millimeter (mm) and meter (m)
Volume
cubic meter (m3)
Length
millimeter (mm) and meter (m)
Volume
cubic meter (m3)
Length
millimeter (mm) and meter (m)
Area
square meter (m2)
Volume
cubic meter (m3)
282
Architectural Drafting and Design
EWING AVENUE
15'
15'
10.00'
1/2 IRON ROD END
IN CONC.
1
100.00'
319.92'
SANDY ESTATES
CITY OF HOUSTON, COUNTY OF HARRIS
STATE OF TEXAS
FIGURE 1421 Small, major subdivision plat.
PACIFIC OCEAN
BEACH
ENTRANCE
EASTWOOD
COVE
N
HWY 101
CARMEL 15 MILES
VICINITY MAP
STREET
CL
R=10.00'
L=13.70'
=89°
S 1°29' 48" W
2
GATLIN
R=25.00'
L=30.77'
=71°
61.19'
90.00'
134.92'
N 88°06' 14" W
FIGURE 1422 Vicinity map.
8
79.28'
R=50.00'
L=22.78'
=28°
30'
65.07'
75.74'
N 88°30'12" W
106.53'
N 1°29' 48" E
R=25.00'
L=7.17'
=16°
20'
25' 25'
N 1°53'46" E
7
MIBRADA LOOP
95.00'
34
°0
11 9' 2
2
2.
93 " W
'
10'
R=10.00' L=15.17' =89°
N 88°30'12" W
171.90'
66.90'
S
75.00'
129.32'
50.00'
R=25.00'
L=32.10'
=75°
3
25.00'
R =50
.00
25.00'
80.00'
N 1°30'31" E
118.54'
117.99'
'
40.09'
L =1
32°
=1
N 1°29'48" E
N 88°30'12" W
8'
L=48.39'
=55°
L=68.92'
=79°
.7
75.00'
S 33°02'56" E
96.07'
53.58'
110.53'
N 88°30'12" W
4
6
N 1°53'46" E
5
10'
73.00'
16
309.98'
111.44'
130.86'
85.70'
CL
15'
10.00'
15'
20'
30'
BEACH
100'
ENTRANCE
GATEHOUSE
PHONE
UNOBSTRUCTED
OCEAN VIEW
25
UNOBSTRUCTED
OCEAN VIEW
RECREATIONAL
SPACE
OPEN SPACE
50
TYPICAL SECTION
OPEN SPACE
75
OPEN
SPACE
100
OPEN SPACE
LAND USE SUMMARY
125
ZONE
R1
GROSS AREA
763
NET AREA
705
119
ROADS PACKING
STRUCTURES (44 UNITS)
44
RECREATIONAL 4 OPEN SPACES 350
INTERFACING
1.92
DENSITY
12.24
150
150
OPEN SPACE
OPEN SPACE
Chapter 14: Legal Descriptions and Site Plan Requirements
PACIFIC OCEAN
ACRES
ACRES
ACRES
ACRES
ACRES
ACRES
UNITS/ACRE
100
OPEN SPACE
75
LEGEND
50
25
PROPERTY BOUNDARY
CONTOURS
NEW FOOT PATHS
PROPOSED ROADS
0
50
100
200
EASTWOOD
COVE
EXISTING TREES
ONE FOURPLEX
283
FIGURE 1423 Planned unit development plan.
DEVELOPMENT PLAN
284
ADDITIONAL RESOURCES
Architectural Drafting and Design
See CD for more information
The following Web sites can be used as a resource to
help you find more information about legal descriptions
and site plans.
These Web site links are also provided on the Student
CD where you can select a link and go automatically to
the specified Web site.
Address
www.blm.gov
www.usgs.gov
Company, Product,
or Service
U.S. Bureau of Land
Management
U.S. Geological Survey
Legal Descriptions and Site Plan
Requirements Test
See CD
for more
information
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 14 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 14–1 Define site.
Question 14–2 What is the difference between the terms
site, plot, and lot?
Question 14–3 Name the three basic types of legal
descriptions.
Question 14–4 How many total degrees are in a compass?
corner of Section 16, Township Number 6 North,
Range Number 4 West.
Question 14–18 List at least six items that are required
on a site plan.
Question 14–19 Define topography.
Question 14–20 Define contour lines.
Question 14–21 What is the purpose of a grading plan?
Question 14–22 Under what conditions is a site analysis
plan normally required?
Question 14–23 What are setbacks?
Question 14–24 Name the two main categories of
sewage disposal systems.
Question 14–25 Identify the type of legal description
that is used for most major subdivisions.
Question 14–5 How many minutes are in 1 degree?
Question 14–6 How many seconds are in 1 minute?
Question 14–7 Define bearing.
Question 14–8 Give the bearing of a property line
positioned 60° from north toward west.
Question 14–9 Give the bearing of a property line
positioned 20° from south toward east.
Question 14–10 Define baselines.
Question 14–11 Define principal meridians.
Question 14–12 Give the dimensions of a township.
Question 14–13 How many acres are in a section?
Question 14–14 How many square feet are in 1 acre?
Question 14–15 How are sections in a township
numbered?
PROBLEMS
Use a word processor to write a report of 250 or fewer
words on one or more of the following topics:
Problem 14–1 Metes and bounds legal description
Problem 14–2 Lot and block legal description
Problem 14–3 Rectangular survey system for legal
description
Problem 14–4 Public land states
Problem 14–5 Site plan requirements
Problem 14–6 Topography
Problem 14–7 Grading plan requirements
Problem 14–8 Site analysis plan
Question 14–16 How many acres are in a quarter section?
Problem 14–9 Subdivision plans
Question 14–17 Give the partial legal description of 2.5
acres of land in the farthest corner of the northwest
Problem 14–10 Planned unit development
Problem 14–11 Metrics in site planning
CHAPTER 15
Site Plan Layout
T
I
O
zoning department. Figure 15-1 is a plat from a surveyor’s
map that can be used as a guide to prepare the site plan.
The scale of the surveyor’s plat may vary, although in
this case the scale is 1" = 200' (1:1000 metric). The site
plan to be drawn can have a scale ranging from 1" = 10'
(1:50 metric) to 1" = 200' (1:2000 metric). The factors
that influence site plan scale include the following:
N
Site plans can be drawn on media ranging in size from
8 1/2" × 11" up to 34" × 44" depending on the purpose of the
plan and the guidelines of the local government agency or
lending institution requiring the plan. Many local jurisdictions
recommend that site plans be drawn on an 8 1/2" × 14" sheet.
●
Sheet size.
● Plot size.
● Amount of information required.
● Amount of detail required.
Before you begin the site plan layout, you need some
important information. This information can often
be found in the legal documents for the property, the
surveyor’s map, the local assessor’s office, or the local
10.00'
75.00'
1/2 IRON ROD END
IN CONC.
75.74'
129.32'
N 1°53'46" E
N 1°53'46" E
25.00'
50.00'
10'
7
R=50.00'
L=22.78'
=28°
8
R=25.00'
L=30.77'
=71°
61.19'
MIBRADA LOOP
66.90'
R=25.00'
L=7.17'
=16°
2
134.92'
N 88°06' 14" W
20'
N 88°30'12" W
106.53'
R=10.00' L=15.17' =89°
N 88°30'12" W
171.90'
30'
90.00'
N 1°29' 48" E
R =50
.00
40.09'
L =1
95.00'
3
34
°0
11 9' 2
2
2.
93 " W
'
R=25.00'
L=32.10'
=75°
S
118.54'
117.99'
25.00'
80.00'
N 1°30'31" E
N 88°30'12" W
'
32°
=1
N 1°29'48" E
8'
L=48.39'
=55°
L=68.92'
=79°
.7
75.00'
S 33°02'56" E
96.07'
53.58'
110.53'
111.44'
N 88°30'12" W
4
6
16
309.98'
5
10'
73.00'
65.07'
130.86'
STREET
C
GATLIN
U
R=10.00'
L=13.70'
=89°
1
100.00'
319.92'
CL
D
S 1°29' 48" W
O
79.28'
R
25' 25'
T
85.70'
N
10.00'
I
20'
30'
FIGURE 151 Plat from a surveyor’s map.
285
286
Architectural Drafting and Design
Additional information that should be determined
before the site plan can be completed usually includes
the following:
minimum of 18' (5.5 m) wide at the garage opening
but can taper to 10' wide at the street entrance. Any
reduction of driveway width should be centered on
the garage door. A turning apron is preferred when
space permits. This allows the driver to back into the
parking apron and then drive forward into the street,
which is safer than backing into the street.
● The minimum turning radius for a driveway should
be 15' (4.5 m). The turning radius for small cars can
be less, but more should be considered for trucks. A
turning radius of 20' (6 m) is preferred if space permits. Figure 15-2 shows a variety of driveway layouts
for you to use as examples. The dimensions are given
as commonly recommended minimums for small to
standard-sized cars. Additional room should be provided if available.
● Provide adequate room for the installation of and
future access to water, sewer, and electrical utilities.
● Do not build over established easements. An easement is the right-of-way for access to property and
for the purpose of construction and maintenance of
utilities.
● Follow basic grading rules, which include not grading on adjacent property. Do not slope the site so as
to cause water drainage onto adjacent property. Slope
the site away from the house. Adequate drainage of at
least 10' away from the house is recommended.
●
Legal description.
● North direction.
● All existing roads, utilities, water, sewage disposal,
drainage, and slope of land.
● Zoning information, including front, rear, and side
yard setbacks.
● Size of proposed structures.
● Elevations at property corners, driveway at street, or
contour elevations.
SITE DESIGN CONSIDERATIONS
Several issues that can affect the quality of the construction project and adjacent properties should be
considered during site design. Some of these factors are
outlined as follows:
●
Provide a minimum driveway slope of 1/4" per foot.
The maximum slope depends on surface conditions
and local requirements.
● Provide a minimum lawn slope of 1/4" per foot if
possible.
● Single-car driveways should be a minimum of 10'
(3 m) wide, and double-car driveways should be a
10' MIN
18' MIN
18' MIN
10' MIN
10' MIN
R12'
MINIMUM
ONE CAR
MINIMUM ONE
CAR WITH PARKING
MINIMUM
TWO CAR
R10'
17'
10' MIN
12'
R15'
R 20'
10'
18'
24'
24'
10' MIN
R 12'
10' TO12' MIN
TURNOUT APRON
PREFERRED
SIDE GARAGE
FIGURE 152 Typical driveway layout options.
U-SHAPED DRIVEWAY
Chapter 15: Site Plan Layout
287
●
Identify all trees that are to remain on the site after
construction.
● Establish retaining walls where needed to minimize the
slope, control erosion, and level portions of the site.
RURAL RESIDENTIAL FIRE DEPARTMENT
ACCESS AND SITE PLANNING
Special considerations need to be made when designing
driveways and turnarounds in rural areas. In urban and
suburban areas, fire truck access is normally designed
into the subdivision plan and each residence is fairly
easy to access for firefighting purposes. Rural locations
pose special problems for firefighting because they are
often larger pieces of property that frequently have long
gravel driveways where access can be limited. Check
the regulations for your location. The guidelines governing the site design can differ from one location to
the next, but the following are common standards:
●
Road clearances: A 15' (4500 mm) minimum width
all-weather surface driveway must be provided, with
an additional 5' (1500 mm) width clear of vegetation. The driveway must also be clear of vegetation
to a height of 13'−6" (4000 mm). All-weather means
gravel or paved surface. Figure 15-3 shows several
basic driveway design options.
● Road load capacities: The driveway must be engineered for a 12,500 lb (5680 kg) wheel load and
50,000 lb (22720 kg) gross vehicle load.
20'
20
'
90'
R2
5'
'
45
5'
R2
20'
20'
HAMMERHEAD
TURNAROUND
Y TURNAROUND
R4
45'
5'
20'
5'
R2
R2
5'
65'
CORNER
20'
ALTERNATE
HAMMERHEAD
TURNAROUND
0'
Ø9
5'
R2
20'
CUL-DE-SAC
TURNAROUND
FIGURE 153 Driveway turnaround options for rural residential fire department access.
288
Architectural Drafting and Design
●
LAYING OUT PROPERTY LINES
In Chapter 14, you were introduced to the methods for
describing properties. Look at Figure 15-1 and notice that
the property lines of each lot and the boundaries of the
plat are labeled with distances and bearings. An example
N
W
112.93'
34˚9'22"
A
FIGURE 154 (A) Drawing a property line. (B) Labeling a property line with the distance and bearing.
is the west property line of Lot 2, which is 112.93' for the
length and S 34°09'22" W for the bearing. This property
line is set up to be drawn as shown in Figure 15-4A.
After the property lines are drawn, they are labeled with
the distance and bearing, as shown in Figure 15-4B.
Many plats have property lines that curve, such as the
lines around the cul-de-sac in Figure 15-1. For example,
the largest curve is labeled R = 50.00' L = 140.09'. R is
the radius of the curve, and L is the length of the curve.
There are three sublengths in this curve: L = 48.39' is
for Lot 4, L = 68.92' is for Lot 6, and L = 22.78' is for
Lot 8. Figure 15-5A shows the setup for drawing this
curve using the radius and arc lengths. Plats also typically show a delta angle for curves, which is represented
by the symbol ∆. The delta angle is the included angle
of the curve. The included angle is the angle formed
between the center and the endpoints of the arc, as
shown in Figure 15-5B. Figure 15-5C shows the final
labeling of the curve.
=162˚
=79˚
L=68.92'
L=22.78'
=55˚
R=50.00'
L=68.92'
=79˚
CENTER
'
00
0.
L =14 0 .09'
=28˚
B
L=22.78'
=28˚
=
16
2
L=
4
=58.3
9
R = 5˚ '
5
A
B
S
L=140.09'
L=48.39'
34
11 ˚09
2. '22
93 "W
'
E
S
Grade: A 10% average minimum road grade is preferred,
but up to 15% for 200' (60000 mm) is acceptable.
● Dead ends: Provide a turnaround if the driveway is
longer than 150' (945000 mm).
● Turnouts: Provide a 20' (6000 mm) wide by 40'
long passage space at the midpoint of every 400'
(122000 mm) length.
● Bridges and culverts: These features must be designed
to support a minimum of 50,000 lb.
● Fire safety zone: Provide a firebreak at least 30'
(9000 mm) around all structures. A firebreak requires
ground cover no more than 24" (600 mm) in height
and all dead vegetation removed. Steep terrain around
the structure can require a greater firebreak.
● Property identification: The property address shall be
posted on a fire department–approved sign where the
driveway meets the main road.
● Firefighting water supply: On-site water supplies, such
as a swimming pool, pond, or water storage tank,
must be accessible within 15'. A fire sprinkler system
designed and installed in the home can be substituted
for a water supply. Additional information about fire
sprinkler systems is provided in Chapter 20.
● Roof coverings in wildfire zones: Wildfire zones are
heavily wooded areas. The use of wood roofing material or other combustible materials is restricted in
these areas.
C
FIGURE 155 Drawing and labeling curved property lines. (A) The setup for drawing the curve. (B) The included angle, the
angle formed between the endpoints and the arc, is 162°. (C) Final labeling of the curve.
Chapter 15: Site Plan Layout
289
CADD APPLICATIONS
Using Surveyor’s Units
Generally, the plat or legal description provides metes
and bounds coordinates for property line boundaries. For
example, the south property line for Lot 2, in Figure 15-1,
has the coordinates given with the bearing and distance of
N 88°06'14" W and 134.92'. CADD systems used for either
general or architectural applications have a surveyor’s
units setting. When the CADD system is set to draw lines
based on surveyor’s units, the south property line of Lot 2
is drawn with this computer prompt: @134.92' < N 88d06'
14" W. Notice that the degree symbol (°) is replaced with
the lowercase letter d when entering a bearing at the
computer prompt.
Most CADD programs have options for drawing arcs that
allow you to create the curves in Figure 15-5. The commands
typically allow you to draw arcs with a combination of radius,
arc length, and included angle. This provides you with the
flexibility needed to use the R, L, and ∆ information provided
on the plat or in the surveyor’s notes. ■
STEPS IN SITE PLAN LAYOUT
STEP 3 Lay out the proposed structure using construc-
Follow these steps to draw a site plan.
STEP 1 Select the paper size. In this case the size is
8 1/2" × 11". Evaluate the plot to be drawn. Lot 2
of Sandy Estates, shown in Figure 15-1, is used for
this example. Determine the scale to use by considering how the longest dimension (134.92') fits on
the sheet. Always try to leave at least a 1/2" margin
around the sheet. CADD scale applications are used
as described in Chapter 7.
STEP 2 Use the given plat as an example to lay out
the proposed site plan. If a plat is not available,
then the site plan can be laid out from the legal
description by establishing the boundaries using
the bearings and dimensions in feet. Lay out the
entire site plan using construction lines. If errors
are made, the construction lines are very easy to
erase, or use CADD layers so construction lines
can be frozen when finished with the drawing (see
Figure 15-6).
tion lines. The proposed structure in this example
is 60' long and 36' wide. The house can be drawn
on the site plan with or without showing the roof. A
common practice is to draw only the outline of the
floor plan. In some cases, the roof overhang is considered in the setback. In these situations, the house
outline is drawn as a dashed line under the roof and
dimensions are given for the house and the overhang.
The front setback is 25', and the east side is 15'. Lay
out all roads, driveways, walks, and utilities. Be sure
the structure is inside or on the minimum setback
requirements. Setbacks are imaginary boundaries
beyond which the structure may not be placed.
Think of setbacks as property line offsets established
by local regulations. Minimum setbacks can be confirmed with local zoning regulations. The minimum
setbacks for this property are 25' front, 10' sides, and
35' back from the property lines to the house (see
Figure 15-7).
SI
DE
SIDE SETBACK
SE
TB
AC
K
FRONT SETBACK
REAR SETBACK
FIGURE 156 Step 2: Lay out the plot plan property lines.
FIGURE 157 Step 3: Lay out the structures, roads, driveways,
walks, and utilities. Be sure the structure is on or within the
minimum required setbacks.
290
Architectural Drafting and Design
MIBRADA LOOP
W
R=25.00' L=7.71'
all property lines, structures,
roads, driveways, walks, and utilities, as shown in
Figure 15-8. Some drafters use a thick line or shading for the structure. Draw each feature on the
appropriate CADD layer.
STEP 5 Add dimensions and contour lines (if any) or
elevations. The property line dimensions are generally placed on the inside of the line in decimal feet,
and the bearing is placed on the outside of the line.
The dimensions locating and giving the size of the
structure are commonly in feet and inches or in decimal feet. Try to keep the amount of extension and
dimension lines to a minimum on the site plan. One
way to do this is to dimension directly to the house
and place size dimensions inside the house outline.
Add all labels, including the road name, property
dimensions and bearings (if used), utility names,
walks, and driveways, as shown in Figure 15-9.
MIBRADA LOOP
W
R=25.00' L=7.71'
18' DRIVE
EL 100'
PROPOSED
3 BEDROOM HOME
EL. MAIN FL. 101.5'
5'
95.00'
60'-0"
134.92'
EL 102'
N 88˚06'14" W
N 1˚29'48" W
36'-0"
34
˚0
9'2
11
2"
2.
W
93
'
E
S
66.90'
S
CURB
W
S
36" WALK
25'-0"
EL 100'
21'
25'
CL
EL 101.2'
FIGURE 159 Step 5: Add dimensions and elevations; then
label all roads, driveways, walks, and utilities.
W
S
EL 100'
PROPOSED
3 BEDROOM HOME
EL. MAIN FL. 101.5'
60'-0"
FIGURE 158 Step 4: Darken boundary lines, structures, roads,
driveways, walks, and utilities.
STEP 4 Complete
66.90'
EL 102'
PLOT PLAN
S
CURB
134.92'
N 88˚06'14" W
SCALE 1"=20'
LEGAL:
LOT 2 SANDY ESTATES
CITY OF HOUSTON,
COUNTY OF HARRIS,
STATE OF TEXAS
5'
95.00'
N 1˚29'48" E
36'-0"
34
˚0
11 9'22
2.
93 " W
'
E
S
36" WALK
18' DRIVE
25'-0"
EL 100'
21'
25'
CL
EL 101.2'
N
FIGURE 1510 Step 6: Complete the plot plan. Add title, scale,
north arrow, legal description, and other necessary information,
such as the owner’s name if required.
STEP 6 Complete the site plan by adding the north
arrow, the legal description, title, scale, client’s name,
and other title block information. Figure 15-10 shows
the complete site plan.
SITE PLAN DRAWING
CHECKLIST
Check off the items in the following list as
you work on the basic site plan, to be sure that you
have included all of the necessary details. Site plans for
special applications may require additional information.
Refer to this chapter for features found in special plans
such as a grading plan, subdivision plan, site analysis
plan, planned unit development, and commercial plan.
❑ Site plan title and scale.
❑ Property legal description.
❑ Property line dimensions and bearings.
❑ North arrow.
❑ Existing and proposed roads with the elevation at the
center of roads.
❑ Driveways, patios, decks, walks, and parking areas.
❑ Existing and proposed structures with floor-level
elevations.
❑ Public or private water supplies.
❑ Public or private sewage disposal.
Chapter 15: Site Plan Layout
❑ Location of utilities.
❑ Rain and footing drains and storm sewer or drainage.
❑ Topography, including contour lines or elevations
at property corners, street center line, driveways, and
floor elevations.
❑ Front, side, and rear setbacks dimensioned and in
compliance with zoning.
❑ Specific items on adjacent properties, if required,
such as existing structures, water supply, sewage
disposal, trees, or water features.
❑ Existing and proposed trees (may be required).
291
A
B
C
D
E
0+00
0+20
0+40
0+60
0+80
DRAWING CONTOUR LINES
Contour lines represent intervals of equal elevation,
as explained in Chapter 14. The following discussion
shows you how to lay out contour lines on a construction site. Surveyors use various methods to establish
elevations at points on the ground. This information
is recorded in field notes. You then use the field notes
to plot the contour lines. This discussion explains the
grid survey method. Another common technique is the
control point survey, which establishes elevations that
are recorded on a map. You then lay out the elevations
for the contour lines based on the given elevation
points. The radial survey is also a common method,
used for locating property corners, structures, natural
features, and elevation points. This system establishes
control points using a process called radiation in which
measurements are taken from a survey instrument
located at a base known as a transit station. From the
transit station, a series of angular and distance measurements are established to specific points on the
ground. You then establish the property lines, land
features, and contours based on these points.
Using the Grid Survey to Draw
Contour Lines
A grid survey divides the site into a pattern similar to
a checkerboard. Stakes are driven into the ground at
each grid intersection. The surveyor then establishes
an elevation at each stake and records this information
in field notes. The spacing of the stakes depends on the
land area and the topography. The stakes are placed in a
grid 10', 20', 50', or 100' apart, for example. The example in Figure 15-11 shows a grid with lines spaced 20'
apart. The vertical lines are labeled with letters, and the
horizontal lines are labeled with numbers called stations.
The station numbers are in two parts: for example,
0 + 20. The first number is hundreds of feet. Zero represents 0 hundreds, or 0'. The first number is followed
F
1+00
FIGURE 1511 Draw a grid at a desired scale. Label the vertical
lines with letters and the horizontal lines with station numbers,
as shown in this example.
by a plus (+) sign. This means that you add the first
number to the second number to get the actual distance
to this station. The second number is in tens of feet. For
example, 0' + 20' = 20', or 1' + 20' = 120'. The intersection of vertical line B and station 0 + 40 is identified
as station B–0 + 40. The field notes record the elevation
at each station, as shown in Table 15-1. For example,
the elevation at A-0 + 80 is 105'.
Station
Elevation
Station
Elevation
A-0 + 00
101'
D-0 + 00
95'
A-0 + 20
104'
D-0 + 20
97'
A-0 + 40
108'
D-0 + 40
99'
A-0 + 60
112'
D-0 + 60
105'
A-0 + 80
105'
D-0 + 80
100'
A-1 + 00
102'
D-1 + 00
94'
B-0 + 00
100'
E-0 + 00
94'
B-0 + 20
102'
E-0 + 20
96'
B-0 + 40
105'
E-0 + 40
98'
B-0 + 60
110'
E-0 + 60
100'
B-0 + 80
104'
E-0 + 80
95'
B-1 + 00
100'
E-1 + 00
92'
C-0 + 00
98'
F-0 + 00
92'
C-0 + 20
100'
F-0 + 20
93'
C-0 + 40
102'
F-0 + 40
95'
C-0 + 60
108'
F-0 + 60
98'
C-0 + 80
102'
F-0 + 80
90'
C-1 + 00
95'
F-1 + 00
85'
TABLE 151 Grid Survey Field Notes
292
Architectural Drafting and Design
B
C
D
100
98
95
94
104
102
100
97
108
105
102
112
110
105
102
E
A
F
B
C
D
92
0+00
101
100
98
95
94
96
93
0+20
104
102
100
97
99
98
95
0+40
108
105
102
108
105
100
98
0+60
112
110
104
102
100
95
90
0+80
105
100
95
94
92
85
1+00
102
FIGURE 1512 Use the field notes in Table 15–1 to label the
elevation at each grid intersection.
Steps in Drawing Contour Lines
Contour lines are drawn from grid survey field notes
using the following steps:
STEP 1 Draw
a grid at a desired scale similar to
Figure 15-11. Use construction lines if you are
drafting manually, or establish a GRID or CONSTRUCTION layer if you are using CADD. Label
the vertical and horizontal grid lines.
STEP 2 Use the field notes to label the elevation at each
grid intersection. The elevations, labeled on the grid
in Figure 15-12, are based on the field notes found in
Table 15-1.
STEP 3 Determine the desired contour interval and connect the points on the grid that represent contour
lines at this interval. The contour interval for the
grid in Figure 15-12 is 2'. This means that you will
establish contour lines every 2', such as at 92', 94',
96', and 98'.
STEP 4 Establish the contour lines at the desired contour interval by picking points on the grid that
represent the desired elevations. If a grid intersection elevation is 100', then this is the exact point
for the 100' elevation on the contour line. If the
elevation at one grid intersection is 98' and the
next is 102', then you estimate the location of 100'
between the two points. This establishes another
100' elevation point.
STEP 5 When you have identified the points for all of
the 100' elevations, then connect the points to create
E
F
92
0+00
96
93
0+20
99
98
95
0+40
108
105
100
98
0+60
104
102
100
95
90
0+80
100
95
94
92
85
1+00
FIGURE 1513 Connect the points at the elevations for each
contour interval.
the contour line (see Figure 15-13). Do this for the
elevation at each contour interval.
STEP 6 Darken the contour lines. The intermediate
lines are thin. The index contour lines are broken
and labeled with the elevation and are generally
drawn thicker than intermediate lines, as shown in
Figure 15-14.
98
106
98
90
A
101
FIGURE 1514 Darken the contour lines. The intermediate
lines are thin, and the index contour lines are thick. The index
contour lines are broken and labeled with the elevation of the
contour line.
Chapter 15: Site Plan Layout
293
DRAWING PROFILES
PROFILE
LINE
As described earlier, a profile is a vertical section of
the surface of the ground, and/or of underlying earth
that is taken along any desired fixed line. The profile
of a construction site is usually through the building
excavation location, but more than one profile can be
drawn as needed. The profile for road construction
is normally placed along the center line. Profiles are
drawn from the contour lines at the section location.
The contour map and its related profile are commonly referred to as the plan and profile. Profiles
can be used to show road grades and site excavation,
among other things. Projecting directly from the
desired cut location on the contour map following
these steps creates the profile:
98
90
˚
106
98
90
location of the desired profile (see Figure 15-15).
STEP 2 Set up the profile vertical scale. The horizontal
scale is the same as the map, because you are projecting directly from the map. The vertical scale can be
the same, or it can be exaggerated. Exaggerated scales
are used to give a clearer representation of the contour
when needed. Establish a vertical scale increment that
is above the maximum elevation and one that is below
the minimum elevation. Figure 15-16 shows how the
vertical scale is set up. Notice that the profile is projected 90° from the profile line on the map.
STEP 3 Project a line from the location where every contour line crosses the profile line on the contour map
(see Figure 15-17).
SCALE: 1" = 20'
110
STEP 1 Draw a straight line on the contour map at the
105
100
95
90
SCALE: 1" = 100'
FIGURE 1516 Project the profile 90° from the start of the profile line. Set up the vertical scale. Label the vertical scale and the
elevation of each contour along the vertical scale. Draw a horizontal line at each contour interval. Label the horizontal scale.
PROFILE
LINE
PROFILE
LINE
98
90
˚
106
98
98
90
SCALE: 1" = 20'
110
106
105
100
98
90
95
90
SCALE: 1" = 100'
FIGURE 1515 Draw a straight line on the contour map at the
location of the desired profile.
FIGURE 1517 Project a line 90° from the location where every
contour line crosses the profile line.
294
Architectural Drafting and Design
EXCAVATION AT
100' ELEVATION
PROFILE
LINE
98
98
90
˚
106
106
98
90
SCALE: 1" = 20'
90
98
110
105
100
FIGURE 1519 Site plan location for the desired level excavation at 100'.
95
90
SCALE: 1" = 100'
FIGURE 1518 Draw the profile by connecting the points
where every two vertical and horizontal lines of the same elevation intersect.
STEP 4 Draw the profile by connecting the points where
every two vertical and horizontal lines of the same
elevation intersect, as shown in Figure 15-18.
DRAWING GRADING PLANS
If you have a specific location on a site where a level
excavation must take place for the proposed construction, you can lay out a grading plan. The grading plan
shows the elevation of the site after excavation. This
plan shows where areas need to be cut and filled. This
is referred to as cut and fill. Cut and fill is the excavation process involving the removal of earth, which is
the cut, and moving earth to another location, which
is the fill. Figure 15-19 shows the site plan location for
the desired level excavation. The following steps can
be used to draw the grading plan for a level construction site:
One unit of rise to one unit of run is specified as 1:1
(see Figure 15-20). The actual angle of repose for
cuts and fills is normally determined by approved
soil engineering or engineering geology reports. The
slope of cut surfaces can be no steeper than is safe
for the intended use and cannot exceed 1 unit
vertical in 2 units horizontal (1:2). Alternative
designs may be allowed if soil engineering and/or
engineering geology reports state that the site has
been investigated and give an opinion that a cut at a
steeper slope is stable and does not create a hazard
ORIGINAL
PROFILE
1
LEVEL
EXCAVATION
1
CUT
CUT
1
1
STEP 1 Determine the angle of repose, which is the
slopes of cut and fill from the excavation site measured in feet of horizontal run to feet of vertical rise.
FILL
ANGLE OF REPOSE
FIGURE 1520 Angle of repose.
Chapter 15: Site Plan Layout
295
EXCAVATION AT
100' ELEVATION
EXCAVATION AT
100' ELEVATION
94
94
96
96
98
104
98
94
94
106
96
106
98
102
98
102
98
96
104
98
106
106
102
104
FIGURE 1522 To establish the cut and fill, mark where the
elevations of the parallel lines around the excavation match the
corresponding elevations of the contour lines.
STEP 4 Connect the points established in Step 3, as
shown in Figure 15-23. The cut and fill areas can be
shaded or left unshaded.
EXCAVATION AT
100' ELEVATION
94
96
98
FILL
FILL
98
98
94
96
CUT
CUT
106
102
104
106
98
90
to property. Fill slopes cannot be constructed on
natural slopes steeper than 1 unit vertical in 2 units
horizontal (1:2). In order to provide a bond with
the new fill, the ground surface must be prepared to
receive fill by removing vegetation, previous unstable
fill material, topsoil, and other unsuitable materials.
Other requirements include soil engineering where
stability, steeper slopes, and heights are issues. Soil
engineering can require benching the fill into sound
material and specific drainage and construction
methods. A bench is a fairly level step excavated into
the earth material on which fill is placed. Any grading
plan with a cut and fill design must be properly engineered. A civil engineer is responsible for the proper
design and construction.
STEP 2 Draw parallel lines around the excavation site,
with each line representing the elevation at the cut
and fill. If the angle of repose is 1:1 and the contour
interval is 2', then these parallel lines are 2' from the
level excavation site. This is determined by multiplying rise times contour interval (1 × 2 = 2 in this
example). Look at Figure 15-21.
STEP 3 The elevation of the excavation is 100'. Elevations
above this are considered cuts, and elevations below
this are fills. To establish the cut and fills, mark
where the elevations of the parallel lines around the
excavation match the corresponding elevations of the
contour lines, as shown in Figure 15-22.
98
104
FIGURE 1521 Draw parallel lines around the excavation site,
with each line representing the elevation at the cut and fill.
106
102
98
106
106
90
104
90
102
FIGURE 1523 Complete the cut and fill drawing by connecting the points. The cut and fill areas can be labeled, and they
can be shaded or left unshaded.
296
Architectural Drafting and Design
CADD APPLICATIONS
Using CADD to Draw Site Plans
INTRODUCTION
There are CADD software programs specifically
designed for drawing site plans. Also available are
complete CADD mapping packages that allow you to
draw topographic maps, terrain models, grading plans,
and land profiles. It all depends on the nature of your
business and how much power you need in the CADD
mapping program. One of the benefits of CADD over
manual drafting is accuracy. For example, you can draw
a property boundary line by giving the length and
bearing. The computer automatically draws the line,
and labels the length and bearing. Continue by entering
information from the surveyor’s notes to draw the entire
property boundary in just a few minutes. Such features
increase the speed and accuracy of drawing site plans.
A residential site plan, drawn using CADD mapping
software, is shown in Figure 15-24.
The needs of the commercial site plan are a little
different from the residential requirements. The
commercial CADD site plan package uses the same
features as the residential application and, additionally,
has the ability to design street and parking lot layouts.
The commercial CADD drafter uses features from symbol
libraries, including utility symbols; street, curb, and gutter
designs; landscaping; parking lot layouts; titles; and
scales. A commercial site plan is shown in Figure 15-25.
47'
3Ø'
35'
21'
33.25'
3Ø'-6"⫾
12Ø'
73.ØØ'
9Ø.ØØ
85.ØØ'
99.ØØ'
45'-Ø"⫾
96.Ø3'
ELEVA
VATION:
UPPER RIDGE
CORNER
NORTHWEST
R
SOUTHWEST CORNER
NORTHEAST
R
CORNER
SOUTHEAST CORNER
A
AVERA
GE HEIGHT
85.ØØ'
LINE OF DECK
1Ø7.ØØ"⫾
102.ØØ⫾
73.ØØ'
LINE OF
DECK
9'-Ø"
6'-6"
TO RESIDENCE
MIN.
13'-Ø"
'
LINE OF RESIDENCE
LINE OF UPPER FLOOR
6'-6"
9Ø.ØØ'
LINE OF 2Ø'-Ø"
FRONT SETBACK
2Ø'-Ø"
MIN.
21'-Ø"
MIN.
99.ØØ'
LINE OF
FOOT BRIDGE
LINE OF
P
PARKING
BRIDGE
PROPERTY
R LINE
CL
S. W. MICHAEL AARON
PLOT
1"
FIGURE 1524 A CADD-drawn site plan.
COURT
PLAN
1Ø'-Ø"
Chapter 15: Site Plan Layout
297
CADD APPLICATIONS
334
336
SCALE: 1" = 40'
S.E. 122nd AVE.
PAD A
PHASE 2
FF 336.0
334
PAD C
PHASE 2
FF 334.0
RD
.
332
332
YS
ID
E
330
32
8
FF 327.17
32
8
32
332
6
32
8
BUILDING A
RETAIL
FF 330.17
330
334
332
338
336
334
330
PAD B
PHASE 2
FF 335.0
340
342
S.
E.
SU
NN
FF
333.17
32
6
330
BUILDING B
GROCERY
FF=325.5
BUILDING E
DRUGSTORE
FF 330.0
BU
32
4
IL
R DI
FF ETA NG
32 IL D
6.6
7
BUILDING C
RETAIL
FF 325.5
324
322
320
FIGURE 1525 A CADD-drawn commercial site plan. Courtesy Soderstrom Architects.
6
32
298
Architectural Drafting and Design
CADD APPLICATIONS
FIGURE 1526 A topographic site plan to be used for developing a terrain model. ArchiCAD images courtesy of Graphisoft, planned
by architects Csaba Szakál and Geörgy Péchy.
DEVELOPING A CADD TERRAIN MODEL
CADD programs are available that allow you to include
site work, landscaping, roads, driveways, retaining
walls, and construction excavation as part of the
project. A terrain model can be created from survey
data or from a topographic site plan. A terrain model
is a three-dimensional (3D) model of the earth surface
or terrain, and is also referred to as a digital terrain
model (DTM). A digital terrain model of a topographic
surface uses information on height, slope, aspect,
breaks in slope, and other topographic features.
Figure 15-26 shows an example of a topographic
site plan to be used for developing a terrain model.
The CADD program recognizes the contour lines or
survey data and creates a 3D model in wireframe
or as a 3D-terrain model, as shown in Figure 15-27.
The terrain model can be viewed from any angle
to help you fully visualize the contours of the site.
Additionally, the terrain model can be used for any of
the following design applications:
• Define borders and property lines.
• Find the elevation at any point, contour line, surface
object, or feature and modify the elevation to
determine how this affects the model.
• Modify the terrain model by editing the contour
shapes.
• Define and display building excavation sites, roads,
and other features.
• Show and calculate cut and fill requirements.
• Display the model in plan or 3D view.
FIGURE 1527 The CADD program recognizes the contour
lines from the site plan in Figure 15-26 and creates (A) a 3D
wireframe model or (B) a 3D-terrain model. ArchiCAD images courtesy Graphisoft, planned by architects Csaba Szakál and Geörgy Péchy.
When the site is designed as desired, the 3D
rendering of the house can be placed on the site, as
shown in Figure 15-28. This is an excellent way to
demonstrate how a client’s home will look when it
is finished.
CADD LAYERS FOR SITE PLAN DRAWINGS
The American Institute of Architects (AIA) CADD Layer
Guidelines establish the Civil (C) category of layers,
which uses a level-one C discipline designator. This
designation is used to group civil content or drawings
prepared by a civil engineering contractor, such as the
objects on a site plan. For example, the C-ESMT layer is
used to draw easement lines. Level-two designations
are also available, and can be used to further classify
specific civil drawing content. The designation CU
(Civil Utilities) is used when it is necessary to place
utility objects, such as sewer lines, in a specific category.
An S (Site) level-two designation is also available and
can be used with the Civil designator (CS) or a noncivil discipline. For example, the AS (Architectural Site)
designation is used to distinguish site content drawn
by the architect or architectural designer. Figure 15-29
lists several common civil drafting layers for site plan
applications.
Chapter 15: Site Plan Layout
299
CADD APPLICATIONS
FIGURE 1528 When the site is designed as desired, a 3D rendering of the
house can be placed on the site. ArchiCAD images courtesy Graphisoft, planned by
architects Csaba Szakál and Geörgy Péchy.
Additional layers are used to categorize drawing
content related to, or sometimes shown on, site plans.
The Survey/Mapping category uses a level-one V
discipline designator to group content associated with
surveying, such as the survey of a site, or drawings
created by the surveyor. For example, the V-CTRL-BMRK
draws a benchmark control point located during a
survey. Survey and mapping layers often use the same
major and minor groups as civil layers, because much of
the information used to prepare a civil drawing comes
from a survey.
Example
The Landscape category uses a level-one L
designation to contain objects associated with a
site landscape, or drawings prepared by a landscape
architect or designer. For example, trees are drawn on
the L-PLNT-TREE layer, an irrigation system is drawn
using an L-IRRG layer, and walkways are drawn on
an L-WALK layer. Landscape plans generally show
the suitable plants for the site, and specify the plants
by their proper Latin names and sometimes their
common names. The architect or designer often
sends the site plan computer drawing file to the
Purpose
Name
Line Type
Line Weight
Dimensions
C-ANNO-DIMS
Continuous
0.25 mm
Borders and title blocks
C-ANNO-TTLB
Continuous
0.70 mm
Buildings and primary structures
C-BLDG
Continuous
0.50 mm
Drain fields
C-DFLD
DASHED
0.35 mm
Driveways
C-DRIV
Continuous
0.35 mm
Easements
C-ESMT
Continuous
0.35 mm
Fences
C-FENC
FENCELINE2
0.35 mm
Underground natural gas lines
C-NGAS-UGND
GAS_LINE
0.35 mm
Power line poles
C-POWR-POLE
Continuous
0.35 mm
Property lines
C-PROP
PHANTOM
0.50 mm
Roads
C-ROAD
Continuous
0.35 mm
Underground sanitary sewer lines
C-SSWR-UGND
DASHED
0.35 mm
Index contour lines
C-TOPO-MAJR
Continuous
0.50 mm
FIGURE 1529 Examples of common CAD site plan line formats. Based on the U.S. National CAD Standard recommended line weights
and AIA CAD Layer guidelines.
300
Architectural Drafting and Design
CADD APPLICATIONS
landscape architect or designer where the file is used
to specify the size, type, and location of the plants.
Details for maintaining the plants, such as a water
sprinkler system and other care requirements, are
also provided on the landscape plan. Figure 15-30
shows a CADD landscape plan without detailed
plant information given on the drawing. In this case,
the plant information is given in a set of written
specifications. ■
curb line
LOT AREA
88321 sf.
property line
retaining wall
N
SITE PLAN
1 1" = 5Ø'-Ø"
LANDSCAPE
FIGURE 1530 A landscape plan showing the location of all trees and plantings. Plant types can be included on the landscape plan
or in separate documents. Courtesy Soderstrom Architects.
GOING
GREEN
301
Designing an Ecosystem
The content for this Going Green feature is taken in part
from Mascord Efficient Living, Building a Sustainable Lifestyle.
ECOSYSTEM
The ecosystem is important to our lifestyles and it is
fragile. An ecosystem is an ecological community that
functions as a unit with its environment. Site disturbance
from construction practices unbalance the local system in
ways that may not be apparent at first glance. Minor site
changes can have a large impact locally and regionally.
Clearing landscape for construction can cause
problems with the management of stormwater, dust,
and erosion. The site can become unstable, and
landslides can occur if the ground becomes saturated
and cannot deal with stormwater. In addition, local
stormwater systems can be flooded with runoff
containing dust, debris, and silt.
Plants imported for landscaping can be invasive
and may not blend with local conditions, causing the
home owner unnecessary maintenance costs. Plant
species introduced into areas where they are not native
can negatively impact local species. A strong invasive
species can eradicate a more delicate native species, and
possibly remove a food source for local wildlife.
Care is needed when working with the site to
prevent unnecessary disturbance of local systems,
and to reduce costs associated with clearing and
re-landscaping areas. Mature plants are well established,
and need less attention than freshly planted seedlings.
A well-designed, climate-appropriate landscape offers
substantial environmental and economical benefits.
Trees and other vegetation control erosion, protect water
supplies, provide food and habitat for wildlife, and clean
the air. Planting trees, shrubs, bushes and hedges can
also be an effective way to provide shade and reduce
your heating and cooling costs. Parallel to understanding
how your landscape works as an ecosystem, approach
your landscape with its unique visual appeal in mind.
The sights, textures, and scents of your home’s landscape
might prove to be the most beautiful and inspiring of all
your home’s efficient features.
and let more heat in during the winter. Alternately, the
properties of dense evergreen trees or shrubs can provide
continuous shade and serve to disperse winds. Shading
and evapotranspiration from trees reduce surrounding
air temperatures by as much as 9°F. Because cool air
settles near the ground, air temperatures directly under
trees can be as much as 25°F cooler than air temperatures
above. Evapotranspiration is the process by which a plant
actively moves and releases water vapor.
Xeriscaping
Xeriscaping is a term for low-water-use landscaping,
whereas designs using native plants are called
naturescaping. Xeriscape gardens have typically been
implemented in areas of the country where there is a hotdry climate. However, busy home owners everywhere are
finding the ease of a low-maintenance garden appealing.
Xeriscaping and naturescaping reduce the need for
watering, weeding, fertilizing, and spreading chemicals.
Xeriscape design does not need to consist of cactus-like
plants, rocks, and bark dust. Good design concentrates on
locating plants where the species can thrive naturally and
using defined areas of irrigation for water conservation
rather than eliminating water use altogether. Mixing
drought-tolerant plants with well-chosen areas of irrigated
plants can produce a beautifully colored and varied garden,
with low-maintenance and low-water requirement. For
example, instead of a large lawn expanse with a highvolume sprinkler system, use a smaller lawn, bordered with
drought-tolerant plants. Add a side flower bed planted
with well-chosen species using an appropriately sized
irrigation system. This provides a much more interesting
landscape with a colorful array of flowers while using a lot
less water—with less maintenance. Figure 15-31 shows
an example of xeriscaping and naturescaping.
Shading
Properly using landscape shade requires you to
understand the size, shape, and location of the moving
shadow that your landscaping elements cast throughout
the year, and as they mature. Landscaping elements can
be used to block sun from windows and shade your walls
and walkways from hot summer rays, providing a method
to reduce the cooling needs of your home. Trees can be
selected with appropriate sizes, densities, and shapes
for almost any shading application. Deciduous trees, for
example, can be planted to block solar heat in the summer
FIGURE 1531 An example of xeriscaping and naturescaping.
Courtesy of Alan Mascord Design Associates, Inc.
302
GOING
GREEN
Designing an Ecosystem (Continued)
Naturescaping
Insects
The use of native plants in your landscape can
balance the ecosystem of the garden, because native
plants have evolved over time to be tolerant of their
surroundings. Native plants can provide correct
nutrients to balance the soil, provide food for local
wildlife, prevent the intrusive behavior of weeds, and
also prevent erosion. However, you do not need to
limit yourself to native plants when designing a
landscape. Irises, roses, lavender, lamb’s ears, Oriental
poppy, Dusty Miller, and tulips are all examples of
plants that should survive in a low-maintenance garden
without overpowering native species. The greatest
pleasure of having a xeriscaped and naturescaped
garden is being able to enjoy the landscape without
spending too much time mowing, pruning, weeding,
and fertilizing.
Insects can be beneficial and are often an essential
part of a garden ecosystem. Most plants can survive
losing more than 25% of their leaf surface. If the soil
is healthy, many plants outgrow the pests or diseases
that afflict them, and there may be a delay between
the initial damage caused by pests and the arrival of
beneficial insects that can control them. To determine
if an insect is a pest or a beneficial addition to your
landscape ecosystem, refer to gardening books or
take a sample to a nursery/garden center that has a
knowledgeable staff.
Hydrozoning
Hydrozoning involves arranging flowers and plants into
areas that need similar amounts of water and nutrients.
Watering requirements are more easily managed if plants
can be placed in defined areas of foliage with similar
needs. Keeping thirsty plants away from your house also
prevents you from needing to soak the foundation wall
when watering.
Irrigation
When designing an automatic irrigation system, make
sure to use smart, programmable sprinkler systems with
moisture sensors that allow you to measure the amount
of water your garden needs at any given time. Typically,
these systems also allow you to control irrigation from
a central shut-off valve. Include a reliable rain sensor
so you do not water when raining. Combine this
system with a rain and wastewater collection system to
maximize efficiency. Choose landscaping elements that
are appropriate to the local climate and require minimal
additional water. The varying root systems of grass,
trees, and flowers all have different water requirements.
Group plants according to the amount of water they
need, and design the irrigation system to accommodate
the specific plants.
Pesticides
Pesticides and fertilizers used on landscaping end
up in the water system. Since many pesticides are
highly toxic to fish and other aquatic life, even a small
amount can be harmful and continues into the food
chain. If you determine that a pest or disease problem
requires intervention, make sure to use the safest
method possible. There are many ways to control pests
without using pesticides. For example, set up covers for
vegetables, put out traps for slugs, and remove aphids,
with water jets, while watering your plants.
Healthy Soil
Healthy soil is the foundation for thriving plants and a
healthy lawn. Healthy plants naturally resist diseases
and pests, and require less care. Adding organic
material to the soil improves drainage and provides
food to the microscopic creatures that provide plant
nutrients. Add 2 to 3 inches of compost or aged manure
every year by turning it into the soil and reuse it as
mulch around plants.
Yard Space
In addition to visual appeals, your yard and garden can
also serve a functional purpose by designating a section
of your yard space for planting herbs, spices, fruits, and
vegetables that pay back over time by reducing the
amount of produce you need to buy. You can keep it
simple by starting out with a few simple herbs. Your
garden will mature quickly and become sustainable.
Chapter 15: Site Plan Layout
303
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you find information related to site plan layout.
These Web site links are also provided on the Student
CD where you can select a link and go automatically to
the specified Web site.
Address
www.autodesk.com
Company, Product, or
Service
AutoCAD Civil 3D, Land
Desktop, Survey, Utility
Design
www.softplan.com
www.eaglepoint.com
www.graphisoft.com
www.bentley.com
www.carlsonsw.com
Building and rendering
applications
Civil design solutions
Design building series,
virtual building
MicroStation, Geopak
Solutions for surveying, civil
engineering, building, and
mining applications
See CD
for more
information
Site Plan Layout Test
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 15 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 15–9 Is it true or false that one of the
advantages of CADD over manual drafting is
accuracy?
Question 15–10 Identify at least one difference between
residential and commercial site plans.
Question 15–11 Define contour lines.
Question 15–12 Describe the control point survey.
Question 15–13 Describe the radial survey.
Question 15–1 What influences the size of the drawing
sheet recommended for site plans?
Question 15–14 What is the transit station?
Question 15–2 What four factors influence scale
selection in drawing a site plan?
Question 15–16 What is the distance to station point
0 + 40?
Question 15–3 List five elements of information that
should be determined before starting a site plan
drawing.
Question 15–17 What is the distance to station point
1 + 60?
Question 15–4 Why are construction lines helpful in
site plan layout?
Question 15–5 Information used to prepare a site plan
may come from one or more of several available
sources. List four possible sources.
Question 15–6 List at least six types of information
that should be determined before the site plan can be
completed.
Question 15–15 Explain how a grid survey is set up.
Question 15–18 Explain the difference between index
and intermediate contour lines.
Question 15–19 Define profile.
Question 15–20 Why is the vertical profile scale
exaggerated?
Question 15–21 In addition to the elevation of the
excavation site, what does the grading plan show?
Question 15–22 Define angle of repose.
Question 15–7 Define setbacks.
Question 15–23 What are field notes?
Question 15–8 If you are using a CADD system to
draw a site plan, what would be a typical prompt in
drawing a 154.92' property line with a N 88°06'14" W
bearing?
Question 15–24 Why is the horizontal scale of the
profile the same as the map scale?
Question 15–25 In a grid survey, what is used to label
the vertical lines?
304
Architectural Drafting and Design
PROBLEMS
DIRECTIONS:
1. Use an 8 1/2" × 14" drawing sheet unless otherwise specified
by your instructor.
2. Select an appropriate scale.
3. Minimum front setback is 25'–0".
4. Minimum rear-yard setback is 25'–0".
5. Minimum side-yard setback is 7'–0".
6. Select, or have your instructor assign, one or more of the plot
plan sketches or drawings that follow.
334 . 43'
EL 108'
Problems 15–1 through 15–7 Begin the selected site
plan problem(s) by drawing the given information.
The site plan will then be completed after you have
selected a residential design project(s) in Chapter 18.
Two evaluations are recommended:
●
Site plan without structures, drives, and utilities.
●
Complete site plan after selection and placement of
structures, drives, and utilities. Structures selected in
Chapter 18.
EL 86'
50° 00' 20" E
A
B
AREA ACCEPTABLE
FOR SEPTIC SYSTEM
AREA UNACCEPTABLE
FOR SEPTIC SYSTEM
E
333.44'
SOUTH BROOKS LN.
R = 10'
E
147 . 8'
N
EL 104'
E
54.8'
167 . 8'
A
15'
PROVIDE WATER WELL
100' MINIMUM TO
SEPTIC SYSTEM
652 . 46'
N 89° 26' 35" W
652 . 65'
N 89° 31' 45" W
B
UTILITY
ALLEY
15'
EL 100'
54.8'
MANCHESTER DRIVE
S
TAX LOT 2300, LOT 12 CLARKES ESTATES
SECTION 17, T. 4 S., R. 3E., SALT LAKE
MERIDIAN, TOOELE COUNTY, UTAH
R = 10'
S
LOT 17, BLOCK 3, PLAT OF
GARTHWICK, YOUR CITY,
COUNTY, STATE
PROBLEM 15-1
PROBLEM 15-2
E
N 0° 48' 30" W
EL 91'
E
EL 90'
UR
138 . 83'
EL 84'
S
G
W
N 0° 48' 40" W
JASAN ROAD
EL 86'
S
E
2'
'4
4.5
11
15
S 86' 00' 10
"E
202.98'
S 68' 40' 44" W
N 89' 49' 16" W
209.15'
30'
G
W
LOT 15
BLOCK 3
BARRINGTON HEIGHTS
YOUR CITY, COUNTY
STATE
LOT 7, BLOCK 2, KYLEE ESTATES
SECTION 12, T. 12 N., R. 14 E., LOUISIANA
MERIDIAN, RAPIDES PARISH, LOUISIANA
PROBLEM 15-3
'
S 12
W
P.O.B.
25
9"
OL
L
1'
1"
KN
NORTH
'4
7'
45
.3
ER
°
1
N2
40
14
C
L RIV
S
CO
N
EL 88'
' 59'
17" W
79.4
3'
T
' 19" E
N 84° 44
'
313 . 30
S 85°
219 .
6
4'
12' 3
7" E
138 . 87'
PROBLEM 15-4
Chapter 15: Site Plan Layout
305
P.O.B.
S 86' 37' 50" E
S
487.19'
W
4'
11
1.1
7'
S2
45
24
N 44' 54' 36" W
30'
'
'
29.05
2
.1
W
N 12' 59' 17" E
76'
P.O.B.
LOT 25
BLOCK 4
BARRINGTON HEIGHTS
YOUR CITY, COUNTY
STATE
PROBLEM 15-5
PROBLEM 15-6
N 31° 59' 23" E 159.17'
PROBLEM 15-7
153.62'
E
Ø'
N 34° 42' 27" E
VIEW DRIV
R 197Ø.Ø
PROPERTY LINE
NORTH
HARBOR
" L 87.58'
LOT 23 OF TRACT # 366Ø
BLOCK # 144
HARBOR VIEW ESTATES
YOUR CITY, COUNTY, STATE
d 2° 32' 5Ø
d 2° 23' 24" L 8Ø.ØØ'
R 1917.87'
PROPERTY LINE
SETTING SUN DRIVE
EAST
190.63'
W
7'25"
S73'1
LOT 29
BLOCK 1
ASHDOWN WOOD
YOUR CITY, COUNTY
STATE
0'
0.
16
21
'
8"
.46
0' 0
324
3' 5
NORTH
42
N2
'3
0"
'
N
'
05
E
DRIV
ON
GT
IN
RR
70'
BA
R=1
'
.25
135
"W
ST. JAMES PLACE
RADIUS LENGTH: 75.31'
NORTH
44
'5
4'
51
36
.1
"E
2'
CL
N5
5' 3
7' 0
10
7"
0'
W
RT
C OU
ALLEN
DAVID
'
RB
7.35
=9
Ø' L
27.Ø
R=3
73'-Ø'
ID
K
784.62'
1"
PLOT
3Ø'-Ø"
LEGAL:
LOT 18 OF HIGHPOINTE
IN THE N.E. 1/4 OF SEC. 34, T15, R2E W.M.
HAPPY VALLEY, CLACKAMAS, COUNTY OREGON
15' PUBLIC
SANITARY SEWER
EASEMENT
SANITARY MANHOLE
PLAN
S 71° 16' 25" E
LINE OF DECK ABOVE
57"
43' 3Ø"
BAC
SET
15'
1Ø' SIDE-YARD SETBACK
24" MAX DEC.
RETAINING WALL
ENTRY DECK
F.F. 194.88'
UPPER FIN FL.
175' ØØ"
LOWER FIN FL.
184' ØØ"
5'-Ø' RETAINING
WALL
ENTRY FIN FL.
135' ØØ"
S
1Ø'
RD
E-YA
6'
0.1
22
48" HIGH MAX
RETAINING
WALL
GARAGE FIN FL.
138' ØØ"
48" HIGH MAX
RETAINING
WALL
4" CONC DRIVEWAY
OVER GRAVEL
FILL
24" MAX DEC.
RETAINING
WALL
CRAWL
SPACE
24" AND 48" HIGH RETAINING WALLS
TO BE RAILROAD TIE OR DEC. STONE
VERIFY WITH OWNER
CU
FACE OF
7'
1°
S4
7.5
18
43.47'
"W
2Ø' FRONT-YARD
SETBACK
32'-Ø'
NOR
TH
' 49
PROBLEM 15-8
33
Ø"
3°
10'-
S4
63.15'
306
Architectural Drafting and Design
Problem 15–8 Draw the complete site plan shown.
195
200
195
K
S 21° 16' 25" E
185
1"
1Ø'-Ø"
GRADING PLAN
264.67'
190
LINE OF DECK ABOVE
57"
43' 3Ø"
BAC
SET
15'
1Ø' SIDE-YARD SETBACK
14" MAX DEC.
RETAINING WALL
ENTRY DECK
F.F. 194.88'
UPPER FIN FL.
153' ØØ"
LOWER FIN FL.
184' ØØ"
5'-Ø' RETAINING
WALL
48" HIGH MAX
RETAINING WALL
GARAGE
FIN FL.
138' ØØ"
48" HIGH MAX
RETAINING
WALL
205
'
RD
E-YA
' SID
1Ø
2
16
20.
24" MAX DEC.
ENTRY FIN FL.
RETAINING
188' ØØ"
WALL
CRAWL
SPACE
4" CONC DRIVEWAY
OVER GRAVEL FILL
185
180
24" AND 48" HIGH RETAINING WALLS
TO BE RAILROAD TIE OR DEC. STONE
VERIFY WITH OWNER
190
2Ø' FRONTYARD
SETBACK
5'
1°
S4
180
43.41'
LEGAL:
LOT 18 OF HIGHPOINTE
IN THE N.E. 1/4 OF SEC. 34, T15, R2E W.M.
HAPPY VALLEY, CLACKAMAS, COUNTY OREGON
15' PUBLIC
SANITARY SEWER
EASEMENT
SANITARY MANHOLE
"W
200
URT
N CO
ALLE
DAVID
973
URB
'
L=
22.ØØ
R=3
C
FACE OF
NOR
TH
' 49
33
3°
PROBLEM 15-9
S4
63.15'
Chapter 15: Site Plan Layout
307
Problem 15–9 Continue the drawing started in Problem 15–8 by drawing the complete grading plan using the layout
for this problem as a guide.
This page intentionally left blank
www.kevinmillerphoto.com
SECTION 4
The Floor Plan
This page intentionally left blank
CHAPTER 16
Floor Plan Symbols
I
N
T
R
O
D
U
C
T
I
O
N
The floor plans for a proposed home provide the future home
owner with the opportunity to evaluate the design in terms of
livability and suitability for the needs of the family. In addition,
the floor plans quickly communicate the overall construction
requirements to the builder. Symbols are used on floor plans
to describe items that are associated with living in the home,
such as doors, windows, cabinets, and plumbing fixtures. Other
symbols are more closely related to the construction of the
home, such as electrical circuits and material sizes and spacing.
One of the most important concerns of the drafter is to carefully
combine all of the symbols, notes, and dimensions on the floor
plan so the plan is uncluttered and easy to read.
In addition to knowing the proper symbols to use,
architects, designers, and architectural drafters should
be familiar with standard products that the symbols represent. Products used in the structures they design such
as plumbing fixtures, appliances, windows, and doors
are usually available from local vendors. Occasionally,
some special items must be ordered far enough in
advance to ensure delivery to the job site on time. By
becoming familiar with standard products, you also
become familiar with their cost. Knowing costs allows
you to determine if the product you consider using is
affordable within the owner’s budget.
WALL SYMBOLS
Floor plans that are easy to read are also easy to build,
because there is less likelihood of construction errors
than with unorganized, cluttered plans. Figure 16-1
shows a typical complete floor plan.
The floor plan is a representation of an imaginary
horizontal cut made approximately 4' (1220 mm) above
the floor line. The relationship of the structure to the
floor plan is shown in Figure 16-2. This example shows
projecting the bottom of the wall onto the floor plan.
Residential floor plans are generally drawn at a scale of
1/4" = 1'–0" (1:50 metric). Architectural templates are
available with a wide variety of floor plan symbols at the
proper scale.
Opinions vary with regard to how walls are drawn on
a floor plan. Practices range from drawing all exterior
walls thicker than interior walls, for contrast, to drawing all exterior and interior walls the same thickness
for convenience and because with manual drafting it is
difficult to draw exact thicknesses.
When the thickness of walls is drawn to the exact
construction dimensions, the material used establishes
these values. Exterior walls can be built using 2 × 4
or 2 × 6 studs. Exterior walls of a home are generally
framed using 2 × 6 studs to accommodate insulation
requirements. The garage can be framed using 2 × 6 or
2 × 4 studs depending on structural needs and desired
CADD APPLICATIONS
A common practice with CADD applications is to
draw the floor plan walls the exact thickness of the
construction materials. This is because the CADD system
is extremely accurate for drafting. Some architectural
CADD programs ask you to specify the exact construction
materials and then set up the wall symbols to match.
CADD programs are also valuable for establishing
information from the drawings. For example, a command
such as DISTANCE can be used to determine the exact
dimension between walls for the length of a cabinet
to be built in that location. This is another reason for
making the drawing accurate. ■
311
312
FIGURE 161 Complete floor plan. Courtesy TKP Architects PC, Golden, Colorado.
Architectural Drafting and Design
Chapter 16: Floor Plan Symbols
313
FIGURE 162 The floor plan is a representation of an imaginary horizontal cut made approximately 4' (1220 mm) above the floor line.
This example shows the project on of the bottom of the walls onto the floor plan.
insulation thickness. Garage walls can be framed using
2 × 4 studs as a cost-saving measure for basic residential
construction. Custom homes and structural requirements generally use 2 × 6 studs for garage wall framing.
Studs are the vertical construction members used for
framing walls and partitions, and the nominal size of
the construction member before milling is 2 × 4 or
2 × 6. The milling process makes the finished member
1 1/2" × 3 1/2" or 1 1/2" × 5 1/2". The metric equivalents
of these lumber dimensions are 40 × 90 mm and 40 ×
150 mm. Exterior and interior construction materials
are then applied to the studs. A wide variety of exterior
materials are used in architectural design, including
horizontal and vertical wood siding and stucco. Stucco
is a type of plaster made from Portland cement, sand,
water, and coloring agents. Exterior siding materials vary
in thickness, and should be determined by the specific
material used. This example uses 1/2" thick exterior
material. Interior finish material can also vary, though
drywall and plaster are commonly used. Drywall is an
interior wall covering installed in large sheets made
from gypsum board. Plaster is a mixture of sand,
cement, and water over a wire mesh used to cover walls
and ceilings. This example uses 1/2" thick interior material. Typical exterior and interior construction is shown
in Figure 16-3.
This text recommends drawing exterior and interior
walls with contrasting thicknesses, such as 6" (150 mm)
exterior and 4" (100 mm) interior when using manual
drafting; drawing the exact wall thickness is recommended
314
Architectural Drafting and Design
7"
5"
1/2" GYPSUM
EXTERIOR
INTERIOR
1/2" GYPSUM
EXTERIOR
INTERIOR
2X6 STUD (5 1/2")
2X4 STUD (3 1/2")
1/2" SHEATHING
SIDING
1/2" SHEATHING
SIDING
TYPICAL 2 × 6
EXTERIOR WALL
TYPICAL 2 × 4
EXTERIOR WALL
2X6 AS NEEDED
9 1/2"
1/2" GYPSUM
EXTERIOR
INTERIOR
EXTERIOR
1/2" GYPSUM
BOTH SIDES
6 1/2"
2X4 STUD
4" MASONRY
1/2" SHEATHING
TYPICAL
2X4 STUDS
1" AIR SPACE
EXTERIOR WALL
WITH MASONRY VENEER
INTERIOR
4 1/2"
INTERIOR WALLS
FIGURE 163 Typical exterior and interior construction.
when a CADD system is used. The actual practice
should be confirmed with your instructor or company
to determine the preferred practice. The samples in this
textbook are typically drawn using CADD with text
that closely matches high-quality architectural hand
lettering, in an effort to maintain quality and demonstrate the best possible drafting representation.
Drawing Exterior Walls
Exterior wood-frame walls are generally drawn 6" thick
at a 1/4" = 1'–0" (1:50 metric) scale for manual drafting, and drawn at the exact wall thickness when using
CADD (see Figure 16-4).
The wall thickness depends on the type of construction. If the exterior walls are to be concrete or masonry
construction with wood framing to finish the inside
surface, they are drawn substantially thicker, as shown
in Figure 16-5. The Figure 16-5 example shows a concrete construction wall with furring constructed inside
for use with a finish material. Exterior frame walls with
masonry veneer construction applied to the outside
surface are drawn an additional 5" (approximately
125 mm) thick with the masonry veneer represented
as 4" (100 mm) thick over a 1" (25 mm) air space and
6" (150 mm) wood-frame walls, as seen in Figure 16-6.
Masonry veneer walls consist of a single nonstructural
external layer of masonry, such as brick or stone, separated by an air space from the structural framing such
as wood, steel, or masonry. Furring is generally small
strips of wood or metal that are applied to a wall or
other surface to act as a fastening piece for the finishing
material.
Drawing Interior Partitions
Interior walls, known as partitions, are commonly
drawn 4" (100 mm) thick when using manual drafting, or to the exact material dimensions, such as 4 1/2"
(114 mm), with CADD. The 4 1/2" (115 mm) dimension
is the 2 × 4 (50 × 100) stud with 1/2" (12 mm) drywall on
each side, as shown in Figure 16-3. The wall thickness
dimension is calculated with these values: 3 1/2" + 1/2"
+ 1/2" = 4 1/2". Drywall refers to any materials used for
interior stud covering that do not need to be mixed with
water before application. The terms wallboard, plasterboard, and gypsum are also used. Gypsum is commonly
used to make drywall. When gypsum is heated and the
Chapter 16: Floor Plan Symbols
315
FIGURE 164 Partial floor plan showing exterior walls and interior partitions. Courtesy Piercy & Barclay Designers, Inc., CPBD.
water is removed, the resulting product is plaster of
paris. This is covered by paper to make drywall sheets.
Walls with 2 × 6 (50 × 150) studs are generally used
behind a water closet (toilet). This wall, commonly
known as an 8" nominal wall, is used to house a soil
stack that is 4" in diameter. The soil stack is a vertical
soil pipe carrying the discharge from the toilet fixture.
The soil stack is too big to be placed in the cavity of a
2 × 4 stud wall. This applies if the water closet is on
an upper floor where the soil stack must run down the
wall below. There is no need for the increase in stud
size if the water closet is on the main floor, because the
soil stack connects directly into the sewer line below
the slab or crawl space. There is also a soil vent that
runs up the wall and vents out the roof. The soil vent,
also called the stack vent or waste vent, allows vapor
to escape and ventilates the system. The soil vent can
be in a standard 2 × 4 stud wall because it normally
measures 1 1/2" in diameter. An additional plumbing
discussion is provided in Chapter 20.
316
Architectural Drafting and Design
8" CONC. WALL
DARK-WALL SHADING
2 X 4 FURRING W/1" AIR
SPACE OR 2 X 4 D.F.P.T.
STUDS @ 16" O.C.
LIGHT-WALL SHADING
FIGURE 167 Wall shading.
FIGURE 165 Concrete exterior wall.
BRICK VENEER OVER 1"
AIR SPACE W/15# FELT
& 26 GA. METAL TIES @
24" O.C. EA. STUD.
FIGURE 166 Exterior masonry veneer.
WALL SHADING AND MATERIAL
INDICATIONS
Several shading methods are used to make walls stand
out clearly from the rest of the drawing. Some drafters
shade walls very dark for accent; others shade the walls
lightly for a more subtle effect, as shown in Figure 16-7.
Other wall shading techniques include closely spaced
thin lines, wood-grain effect, and the use of color.
Office practice that requires light-wall shading can
also use thick wall lines to help accent the walls and partitions so they stand out from other floor plan features.
Thick wall lines are also used to accent walls on the plan
when no wall shading is used.
Figure 16-8 shows how walls and partitions appear
when outlined with thick lines. This method is not
FIGURE 168 Thick lines used on walls and partitions. No wall
shading is used.
used when dark wall shading is used, because the
darker shading results in walls and partitions that
stand out clearly from other floor plan features. Some
architectural drafters prefer to draw walls and partitions
unshaded with a thick outline.
Drawing Partial Walls
Partial walls are used as room dividers in situations
where an open environment is desired. For example,
a partial wall can be used as a guardrail at balconies
or next to a flight of stairs. Partial walls require a
minimum height of 36" above the floor and are often
capped with wood or can have decorative spindles
that connect to the ceiling. Partial walls can be differentiated from other walls by drawing wood grain
or by using very light shading; partial walls should be
defined with a note that specifies the height, as shown
in Figure 16-9.
CADD APPLICATIONS
CADD drawings create different line weights by
placing each drawing element on its own layer. The
wall layer is then set to print or plot as thick lines.
CADD programs also offer the flexibility of leaving the
walls open or filled as desired. With some architectural
CADD programs, you can select either option. With a
standard CADD program, you can use commands that
are designed to fill areas. ■
Chapter 16: Floor Plan Symbols
317
LOFT
36" HIGH GUARDRAIL
DINING
48" HIGH
ROOM DIVIDER
W/ OAK CAP
OPEN TO LIVING RM.
BELOW
FLOOR PLAN REPRESENTATION
GUARDRAIL AT LOFT OR BALCONY
FIGURE 169 Partial wall used as a partition wall or room
divider.
4"
MA
X
PICTORIAL
36" HIGH GUARDRAIL
4" MAX
DECK
Drawing Guardrails
Guardrails are generally constructed with horizontal
rails or vertical posts, and are used for safety at balconies, lofts, stairs, and decks over 30" (762 mm) above
the next lower level. Residential guardrails, according to
International Residential Code (IRC), should be noted
on floor plans as being at least 36" (915 mm) above the
floor and should include another note specifying that the
intermediate rails should not have more than a 4" (100
mm) open space. The minimum space helps ensure that
small children do not fall through or become trapped
between the rails or posts. Decorative guardrails are also
used as room dividers, especially at a sunken area or to
FLOOR PLAN REPRESENTATION
PICTORIAL
GUARDRAIL AT DECK
FIGURE 1610 Guardrail representations.
create an open effect between two rooms. Guardrails
are commonly made of wood, steel, or wrought iron.
Creatively designed guardrails add a great deal to the aesthetics of the interior design. Figure 16-10 shows guardrail designs and how they are drawn on a floor plan.
CADD APPLICATIONS
Drawing Floor Plan Walls Using CADD
Using CADD to lay out the walls of a floor plan is
essential in the development of construction documents.
Available programs range from simple CADD drafting
packages that draw two-dimensional (2D) lines to
represent walls to complex modeling programs that
create three-dimensional (3D) wall objects.
Most CADD programs provide basic tools used to create
lines and arcs that are parallel, providing the representation
of a wall in a floor plan view. For example, drawing a single
line and copying it parallel to the initial line is a traditional
method for drafting floor plan walls. As lines are drafted, the
wall intersections must be manually cleaned up to give the
appearance of walls in a floor plan. The addition of door and
window symbols also requires that the wall lines be broken
to add these symbols to the floor plan (see Figure 16-11).
Many of the advanced CADD architectural programs
use tools that represent real-world building objects.
Oftentimes, these real-world building objects display the
FIGURE 1611 Traditional 2D CADD drafting practices use a
series of parallel lines to represent walls in a floor plan. Courtesy
Ron Palma, 3D-DZYN.
318
Architectural Drafting and Design
CADD APPLICATIONS
wall as 2D parallel lines as they appear in a typical floor
plan view. These same objects include 3D properties
that allow the wall to be displayed in an elevation,
section, and 3D modeling view. By drawing a single wall
object, multiple displays of the wall can be obtained
automatically for any view, as shown in Figure 16-12.
A few benefits can be obtained by using advanced
CADD programs that create real-world building objects
such as walls. Some of these benefits include the following:
• Real-world wall types such as brick, wood, metal studs,
and concrete are often available or can quickly be
defined and drawn in the floor plan.
• Automatic wall intersection cleanup saves time
“cleaning up” the floor plans.
• Ends of walls are automatically capped, eliminating
the need to add a line at the end of two parallel lines.
• Curved walls are quickly created with appropriate
building materials.
• The insertion of doors and windows creates a
relationship between the items automatically creating
the “hole” where a door or window is placed. This
eliminates the need for manually trimming and
erasing line work.
• The walls and other floor plan features are parametric,
which means that changes to the wall type, materials
applied, or sizes, cause the wall types to be updated
automatically.
• Building material lists are easier to compile when
materials have been added to the walls in the floor
plan.
• Information about the walls such as surface area and
wall height can be obtained quickly and automatically
placed in a schedule.
• Renderings of a building can be created by applying
the desired materials.
• Elevations and sections are generated automatically. ■
FIGURE 1612 Using real-world building objects, walls can be drawn to display 2D floor plan walls,
2D elevation and section walls, and 3D walls for model views. Courtesy Ron Palma, 3D-DZYN.
DOOR SYMBOL REPRESENTATIONS
Exterior doors are drawn on the floor plan with the sill
shown on the outside of the house. The sill is commonly
drawn projected about 1/16", although it can be drawn
flush depending on individual company standards. A sill
is the framing member that forms the bottom edge of
an exterior door or window opening (see Figure 16-13).
The main entry door is usually at least 3'−0" (915 mm)
wide, although a 2'−8" (813 mm) minimum door width
is allowed by code. An exterior door from a garage or
utility room is usually 2'−8" (813 mm) wide, although
Chapter 16: Floor Plan Symbols
319
3" MIN.
DRAWN WITH
FLUSH SILL
DRAWN WITH
PROJECTED SILL
PICTORIAL
FLOOR PLAN REPRESENTATION
FIGURE 1613 Exterior door.
3'−0" is a good width if space permits. Exterior doors
are typically solid wood or hollow metal with insulation.
Doors can be smooth or slab, or they can feature decorative panels on the surface or in their construction. Doors
are typically 6'−8" (2032 mm) high, although 8'−0"
(2438 mm) doors are available. Refer to Chapter 9 for a
review of code requirements for exterior doors.
The interior door symbol, as shown in Figure 16-14, is
drawn without a sill. Interior doors should swing against
a wall into the room being entered. Interior doors are typically placed at a minimum of 3" (80 mm) from a corner,
or at a maximum of 24" (600 mm) from the corner, allowing for furniture placement behind the door, if desired.
Increasing the 3" minimum from a corner is important
when using wide casing, which is common in custom
home design. Casing is the trim around doors and windows. Common minimum interior door sizes are:
●
2'−8" (800 mm): Utility rooms
● 2'−8" (800 mm) to 2'−6" (760 mm): Bedrooms,
dens, family rooms, and dining rooms
● 2'−6" (760 mm) to 2'−4" (700 mm): Bathrooms
● 2'−4" (700 mm) to 2'−0" (600 mm): Closets (or
larger for bifold and bipass doors)
Metric door sizes vary from 600 mm to 1000 mm
depending on use and location. The Americans with
Disabilities Act (ADA) specifies a minimum opening
36" (915 mm) wide for wheelchair access. This is a
clear, unobstructed dimension measured to the edge
of the door at 90º, if the door does not open 180°. The
larger-sized door is normally used in more expensive
homes with wider halls; smaller-sized doors are usually
used in homes where space is limited. Interior doors can
have a flush surface or have raised panels or glass panels
depending on the desired architectural design.
Pocket doors are commonly used when space
for a door swing is limited, as in a small room (see
Figure 16-15). Pocket doors should not be placed
where the pocket is in an exterior wall or there is interference with plumbing or electrical wiring. Pocket doors
should follow the same size guidelines as interior swinging doors. Pocket doors are more expensive to purchase
and install than standard interior doors, because the
pocket door frame must be built while the house is
being framed. The additional cost is often worth the
results, when design factors require a pocket door.
A common economical wardrobe uses the bipass
door, as shown in Figure 16-16. Bipass doors normally range in width from 4'−0" through 12'−0"
(1200 through 3660 mm) in 1' (300 mm) intervals.
Pairs of doors are usually adequate for widths up to
8' (2400 mm). Three panels are usually provided for
doors between 8' and 10' wide, and four panels are
normal for doors wider than 10'. Bifold wardrobe or
closet doors are used when complete access to the
closet is required. Sometimes bifold doors are used on
a utility closet that houses a washer and dryer or other
utilities (see Figure 16-17). Bifold wardrobe doors
often range in width from 4'−0" (1200 mm) through
9'−0" (2700 mm), in 6" (150 mm) intervals.
Double-entry doors are common where a large
formal foyer design requires a more elaborate entry than
can be achieved by one door. The floor plan symbol for
3" MIN.
FLOOR PLAN REPRESENTATION
DOOR SHOULD SWING
AGAINST WALL
FLOOR PLAN REPRESENTATION
FIGURE 1614 Interior door.
PICTORIAL
PICTORIAL
FIGURE 1615 Pocket door.
320
Architectural Drafting and Design
LINE OF ROD
BELOW SHELF
EXTERIOR
PROJECTED SILL
SHELF LINE
FLUSH SILL
FLOOR PLAN REPRESENTATION
PICTORIAL
FIGURE 1616 Bipass door.
FLOOR PLAN REPRESENTATION
FLOOR PLAN REPRESENTATION
PICTORIAL
FIGURE 1619 Glass sliding door with exterior sill.
PICTORIAL
FIGURE 1617 Bifold door.
double-entry and French doors is the same; therefore,
the door schedule should clearly identify the type of
doors to be installed. The term French doors normally
refers to double exterior or interior doors that have glass
panels and swing into a room (see Figure 16-18).
French doors are used in place of glass sliding doors
when a more traditional door design is required. Glass
sliding doors are associated with contemporary design
and do not take up as much floor space as French
doors. French doors can be purchased with wood mullions and muntins between the glass panes or with
one large glass pane and a removable decorative grill
for easy cleaning, as shown in Figure 16-18. Mullions
are horizontal or vertical dividers between sections of
a window. Muntins are horizontal or vertical dividers
within a section of a window. French doors range in
OMIT SILL LINE FOR
INTERIOR DOUBLE DOORS
width from 2'–4" (700 mm) through 3'–6" (1060 mm)
in 2" (50 mm) increments. Doors can be used individually, in pairs, or in groups of three or four. The threeand four-panel doors typically have one or more fixed
panels, which should be specified.
Glass sliding doors are made with wood or metal
frames and tempered glass for safety. Figure 16-19
shows the floor plan symbols for representing a flush
and a projected exterior sill. These doors are used to
provide glass areas and are excellent for access to a patio
or deck. Glass sliding doors typically range in width
from 5'−0" through 12'−0" (1500 through 3600 mm)
at 1' (300 mm) intervals. Common sizes are 6'−0" and
8'−0" (1800 to 2400 mm).
Double-acting doors are often used between a kitchen
and eating area, to swing in either direction for easy
passage (see Figure 16-20). Common widths for pairs
of doors range from 2'−6" (760 mm) through 4'−0"
(1200 mm) in 2" increments.
Dutch doors are used when it is desirable to have
a door that may be half open and half closed. The top
portion can be opened and used as a pass-through (see
Figure 16-21). Dutch doors range in width from 2'−6"
(760 mm) through 3'−6" (1060 mm) in 2" (50 mm)
increments.
SINGLE
DOUBLE
FLOOR PLAN REPRESENTATION
FIGURE 1618 Double-entry or French doors.
PICTORIAL
FLOOR PLAN REPRESENTATION
FIGURE 1620 Double-acting doors.
PICTORIAL
Chapter 16: Floor Plan Symbols
321
FLOOR PLAN REPRESENTATION
PICTORIAL
FIGURE 1621 Dutch doors.
DRAWN WITH DASHED
LINES TO DENOTE OPEN DOOR
HEADER
FIGURE 1623 Overhead garage door.
Accordion doors can be used at closets or wardrobes,
or they are often used as room dividers where an openable partition is needed. Figure 16-22 shows the floor
plan symbol for an accordion door. Accordion doors
range in width from 4'−0" (1200 mm) through 12'−0"
(3600 mm) in 1' increments. Commercial doors are
available for larger openings. Standard metric door sizes
for all large openings such as sliding glass or double
French doors vary from 1500 to 3600 mm.
The floor plan symbol for an overhead garage door is
shown in Figure 16-23. The dashed lines show the size
and extent of the garage door when open. The extent of
the garage door is typically shown when the door interferes with something on the ceiling. The garage door
header is normally shown as a hidden line, and the size
is labeled with a note. A header is a horizontal structural
member that supports the ends of joists or rafters and
the load over an opening.
Garage doors range in width from 8'−0" through
18'−0" (2400 through 5400 mm). An 8'−0" door is
a common width for a small single car. A size of 9'–0"
(2700 mm) or 10'−0" (3000 mm) is common for a single
door and accommodates a pickup truck or large van. A
door 16'−0" (4800 mm) is a common double-car width.
Doors are typically 7'−0" (2100 mm) high, although door
heights of 8'−0" (2400 mm) or 10'−0" (3000 mm) are
common for campers or recreational vehicles. Standard
metric sizes for door height vary from 2400 to 5400 mm.
WINDOW SYMBOL REPRESENTATIONS
Window symbols are drawn with a sill on the outside
and inside. A sliding window, shown in Figure 16-24, is
a popular 50%-openable window. Notice that windows
can be drawn with exterior sills projected or flush, and
the glass pane can be drawn with single or double lines.
The method used should be consistent throughout the
plan and should be determined by the preference of the
specific architectural office. Many offices draw all windows with a projected sill and one line to represent the
glass; the type of window can then be specified in the
window schedule.
Windows are typically manufactured in widths ranging from 1'−0" (300 mm) through 12'−0" (3600 mm)
at intervals of about 6" (150 mm). Vinyl- and aluminumframe windows generally fall within the range of
these nominal sizes, but sizes of wood-frame windows are often different and should be confirmed
EXTERIOR
PROJECTED SILL
FLUSH SILL
FLOOR PLAN REPRESENTATION
WINDOWS DRAWN WITH
DOUBLE LINES
PICTORIAL
FIGURE 1622 Accordion door.
FLOOR PLAN REPRESENTATION
FIGURE 1624 Horizontal sliding window.
PICTORIAL
322
Architectural Drafting and Design
with the manufacturer’s specifications. Metric
window sizes also vary and should be confirmed.
The location of a window in the house and the way the
window opens are factors that affect the window size. A
window between 6'−0" (1800 mm) and 12'−0" (3600
mm) wide is common for a living, dining, or family
room. To let the occupants take advantage of a view
while sitting, windows in these rooms are normally
between 4'−0" (1200 mm) and 5'−0" (1500 mm) tall.
Windows in bedrooms are typically 3'−0" (900 mm)
to 6'−0" (1800 mm) wide. The height often ranges from
3'−6" (1060 mm) to 4'−0". The type of window used in
the bedroom is important because of emergency egress
requirements in most codes. See Chapter 9 for a review.
Kitchen windows are often between 3'−0" (900 mm)
and 5'−0" (1500 mm) wide and between 3'−0" (900
mm) and 3'−6" (1060 mm) tall. Wide windows are nice
to have in a kitchen for the added light they provide,
but the number of upper cabinets may be reduced to
accommodate a wider window. If the tops of windows
are at the normal 6'−8" height, windows deeper than
3'−6" (1060 mm) can interfere with the countertops.
Bathroom windows often range between 2'−0" and
3'−0" (900 mm) wide, with an equal height. A wider
window with less height is often specified if the window
is to be located in a shower area. Most bathroom windows have obscure glass.
Types of Windows
Casement windows can be 100% openable and are
best used where extreme weather conditions require a
tight seal when the window is closed, although these
windows are in common use everywhere. Casement
windows open from the outside vertical edge, generally
using a crank mechanism (see Figure 16-25). Casement
windows can be more expensive than sliding units.
The traditional double-hung window has a bottom
panel that slides upward, as shown in Figure 16-26, and a
EXTERIOR
PROJECTED SILL
FLUSH SILL
FLOOR PLAN REPRESENTATION
PICTORIAL
FIGURE 1626 Double-hung window.
top panel that slides downward. A double-hung window
operates by means of two sashes that slide vertically past
each other. The sashes form a framework that holds the
panes of a window in the window frame. Double-hung
wood-frame windows are designed for energy efficiency
and are commonly used in traditional architectural
designs. Double-hung windows are typically taller than
they are wide. A double-hung window usually ranges
in width from 1'−6" through 4'−0" (1200 mm). It is
common to have double-hung windows grouped together
in pairs of two or more. A single-hung window is drawn
using the same symbol as a double-hung window. The
difference in type is described in the window schedule,
which is discussed later in this chapter. A single-hung
window has two sashes of glass; the top sash is stationary
and the bottom sash is movable.
Awning windows are often used in basements or
below a fixed window to provide ventilation. An awning
window is a single-sash window that tilts outward and up.
Another common use places awning windows between
two different roof levels, providing additional ventilation
in vaulted rooms. These awning windows are opened
with a long pole connected to the opening device.
Awning windows are hinged at the top and swing outward, as shown in Figure 16-27. Hopper windows are
EXTERIOR
EXTERIOR
PROJECTED SILL
PROJECTED SILL
FLUSH SILL
FLUSH SILL
FLOOR PLAN REPRESENTATION
FIGURE 1625 Casement window.
PICTORIAL
FLOOR PLAN REPRESENTATION
FIGURE 1627 Awning window.
PICTORIAL
Chapter 16: Floor Plan Symbols
323
EXTERIOR
PROJECTED SILL
FLOOR PLAN REPRESENTATION
12"-18"
FLUSH SILL
FLOOR PLAN REPRESENTATION
PICTORIAL
18"-24"
FIGURE 1628 Jalousie window.
CASEMENT/
FIXED
SLIDING/FIXED
FIXED
FIXED
OVER
OVER
SLIDING AWNING
ELEVATION VIEWS
ALUMINUM FRAME
48"-60"
DIMENSIONS FOR A COMMON
SMALL-SIZE BAY WINDOW
drawn in the same manner; however, they hinge at the
bottom and swing inward. Jalousie windows are used
when a louvered effect is desired, as seen in Figure 16-28.
A Jalousie window has overlapping narrow glass, metal,
or wooden louvers, and is operated with a crank handle
for adjusting the louver angle outward.
Fixed windows are popular when a large, unobstructed area of glass is required to take advantage of a
view or to allow for solar heat gain. A fixed window has
a single nonoperable glass pane. Figure 16-29 shows the
floor plan symbols for fixed windows.
Bay windows are often used when a traditional architectural style is desired. Figure 16-30 shows the floor
plan representation of a bay window. Usually, the sides
are drawn at a 45° or 30° angle. A bay window is constructed by extending the exterior of a structure. The
bay window allows more light and provides more floor
space than a window flush with the wall line. A bay
DOUBLE
HUNG/FIXED
6'-0"
18"-24"
3"
M
IN
.
3" MIN.
WOOD FRAME
EXTERIOR
PROJECTED SILL
FLUSH SILL
PICTORIAL
FLOOR PLAN REPRESENTATION
FIGURE 1629 Options for fixed windows. The fixed part of
combination windows is shaded for reference.
PICTORIAL
FIGURE 1630 Bay window.
window can be rectangular, polygonal, or arc-shaped.
An arc-shaped bay window is called a bow window. A
bay window is also called an oriel window, when it projects from an upper story and is supported by corbels.
Corbel refers to the stone, brick, timber, or metal projecting out from a wall to support a structure above.
The depth of the bay is often between 18" and 36"
(450 to 900 mm). The total width of a bay is limited by
the size of the center window, which is typically either
a fixed panel, double-hung, or casement window. Large
bays can have more than one window at the center and
sides. Bays can be either premanufactured or built at the
job site. Bay windows are designed for a specific size and
location. The bay window structure commonly extends
from the floor to the ceiling. The roof of the house can
be extended down to cover the bay window if adequate
ceiling height is available. The bay window commonly
has its own roof structure, which often adds to the quality of the exterior architectural design. The bay window
structure can also be framed with a bench seat if it
does not extend to the floor. The actual design and size
depend on the purpose and the available space.
324
Architectural Drafting and Design
SCHEDULES
EXTERIOR
FLOOR PLAN REPRESENTATION
PICTORIAL
FIGURE 1631 Garden window.
A garden window, as shown in Figure 16-31, is generally a 90° bay window that extends beyond the exterior, with a glass front, sides, and roof to allow in extra
natural light. The garden window is a popular style for
utility rooms and kitchens. Garden windows usually
project between 12" and 18" (300 to 450 mm) from the
wall. Depending on the manufacturer, either the side or
the top panels open.
Numbered symbols used on the floor plan key specific
items to charts known as schedules. As defined by the
U.S. National CAD Standard, a schedule is a grouping
of related items with corresponding distinguishing features, with a heading and a minimum of three columns
of related information. A schedule formats information
into rows and columns in order to more easily present design information. Schedules are used to describe
items such as doors, windows, appliances, materials,
fixtures, hardware, and finishes (see Figure 16-37).
Schedules help keep drawings clear of unnecessary
notes because the details of an item are off the drawing
or on another sheet. The schedule heading generally
uses 3/16" to 1/4" (5 to 6 mm) high text, with 1/8"
(3 mm) high text used in the columns and rows. The
lines used to create the schedules can all be the same
thickness, or varying line thicknesses can be used for
borders and between columns, depending on the desired
office or school practice.
Content of Schedules
Skylights
Consider using a skylight when additional daylight
is desirable in a room, or to let natural light enter an
interior room through the ceiling. Fixed or operable
skylights are available. Skylights are made of plastic
in a dome shape or flat tempered glass. Tempered
double-pane insulated skylights are energy efficient,
do not cause any distortion of view, and generally are not more expensive than plastic skylights.
Figure 16-32 shows how a skylight is represented
in the floor plan. Other floor plan representations
and construction details are used depending on the
manufacturer specifications. Confirm the correct
representation with the manufacturer.
There are many different ways to set up a schedule, and
a schedule can include any or all of the following product information:
Manufacturer’s name
Product name
Model number
Type
Quantity
Size
Rough opening size
Color
Placement of quantities on schedules varies among
offices, although giving quantities is the preferred practice. During the early stages of plan development, the
drafter or designer refers to manufacturer catalogs for
products to be used in the design and begins to establish
the schedule data.
Schedule Key
24"X36" DBL GLAZE
INSULATED SKYLIGHT
FLOOR PLAN REPRESENTATION
FIGURE 1632 Skylight representation.
PICTORIAL
When doors and windows are described in a schedule,
they must be keyed from the floor plan drawings to
the schedule. The key may label windows with a letter
and doors with a number. You can enclose the letters
or numbers in different geometric figures, such as the
following:
1
2
1
A
2
B
GOING
GREEN
325
Windows and Energy Loss
INSULATED WINDOWS
Windows can be a big source of energy loss by heat
escaping from the home during the winter and by
allowing extra heat to enter the home during the
summer. Doors can also contribute to loss of energy
efficiency in the home. However, doors are generally
more energy efficient than windows.
There are a variety of ways to insulate windows.
One common method is to use two or more panes of
glass with a sealed space between. This is referred to
as insulating glass. Another technique is to fill the
sealed space with argon, a colorless gas that raises the
window’s insulating value. Low-emissive glass, also
called low-e glass, is an additional technology that
improves windows’ energy efficiency. Low-e glass has a
transparent coating that acts as a thermal mirror, which
increases insulating value, blocks heat from the sun,
and reduces fading of objects inside the house. Window
frames made of wood or a combination of materials
that have a thermal break installed are an advantage
in terms of energy efficiency. A thermal break system is
a longitudinal channel, longitudinal flange, or sidewalls
that create a hollow center in which a thermal barrier is
integrally formed.
Insulation is rated by R-value, and windows are rated
by U-value. R is the reciprocal of the U-value: 1/U = R.
U-value is the coefficient of heat transfer expressed as
BtuH sq ft/°F of surface area. BtuH is heat loss calculated
in Btu per hour. Btu means British thermal unit, a
measure of heat. The lower the U-value, the more the
insulating value. The U-value of windows can also be
identified by window class (CL). For example, a window
with a U-value of 0.40 is CL40.
The National Fenestration Rating Council
The following is taken in part from the NFRC Web
site. The National Fenestration Rating Council (NFRC)
is a nonprofit organization that administers the only
uniform, independent rating and labeling system for
the energy performance of windows, doors, skylights,
and attachment products. The term fenestration is any
opening in a building’s envelope including windows,
doors, and skylights.
The NFRC Label. Adopted in 2005, the NFRC energy
performance label can help you determine how well
a product performs the functions of helping to cool
your building in the summer, warm your building in
the winter, keep out wind, and resist condensation. By
using the information contained on the label, builders
and consumers can reliably compare one product
with another, and make informed decisions about the
windows, doors, and skylights they buy.
FIGURE 1633 The NFRC energy performance label. Courtesy
National Fenestration Rating Council (NFRC).
The NFRC label lists the manufacturer, describes the
product, provides a source for additional information,
and includes ratings for one or more energy performance
characteristics (see FIGURE 1633). All energy performance
values on the label represent the rating of windows and
doors as whole systems, which includes glazing and
frame. Refer to FIGURE 1633 as you review the following
information found on the NFRC label:
U-Factor. U-factor measures how well a product prevents
heat from escaping. The rate of heat loss is indicated in
terms of the U-factor (U-value) of a window assembly.
U-factor ratings generally fall between 0.20 and 1.20. The
insulating value is indicated by the R-value, which is the
inverse of the U-value. The lower the U-value, the greater
a window’s resistance to heat flow and the better its
insulating value.
Solar Heat Gain Coefficient. Solar heat gain coefficient
(SHGC) measures how well a product blocks heat caused
by sunlight. The SHGC is the fraction of directly transmitted
and absorbed solar radiation admitted through a window
and then released inward. SHGC is expressed as a number
between 0 and 1. The lower a window’s solar heat gain
coefficient, the less solar heat it transmits in the house.
Visible Transmittance. Visible Transmittance (VT)
measures how much light comes through a product. The
326
GOING
GREEN
Windows and Energy Loss (Continued)
visible transmittance is an optical property that indicates
the amount of visible light transmitted. VT is expressed
as a number between 0 and 1. The higher the VT, the
more light that is transmitted.
Air Leakage. Air Leakage (AL) is indicated by an air leakage
rating expressed as the equivalent cubic feet of air passing
through a square foot of window area (cfm/sq ft). Heat
loss and gain occur by infiltration through cracks in the
window assembly. The lower the AL, the less air that
passes through cracks in the window assembly.
Condensation Resistance. Condensation Resistance (CR)
measures the ability of a product to resist the formation
of condensation on the interior surface of the product.
The higher the CR rating, the better the product is at
resisting condensation formation. While this rating
cannot predict condensation, it can provide a credible
method of comparing the potential of various products
for condensation formation. CR is expressed as a number
between 0 and 100.
TUBULAR DAYLIGHTING DEVICES
One of the key components of any floor plan is to
determine accurate and adequate lighting needs.
Daylighting is often a major consideration. Utilizing
natural light in addition to or in place of artificial
lighting may be a decision that is made based on safety
considerations, aesthetic preferences, environmental
practices, cost efficiency, or even health benefits and
retail sales. However, daylight is not always readily
available within every space, especially in small rooms,
corridors, and multiple-story buildings. Daylighting is the
use of various design techniques to enhance the use of
natural light in a building.
A natural lighting option that is often selected for
its compact size, technologically advanced abilities,
and flexibility is the Tubular Daylighting Device
(TDD). Figure 16-34 shows an example of a Tubular
Daylighting Device. The standard model is a passive
system consisting of a transparent, roof-mounted
dome with a self-flashing curb, reflective tubing, and
a ceiling-level diffuser assembly that transmits the
daylight into interior spaces.
The following features of TDDs are particularly critical.
Even though the differences in these components may
seem minor, slight variances can make the difference
between a poorly lit space and a well-designed, environmentally conscious interior.
Capture
For the TDD to effectively bring daylight into interior
spaces, sunlight capture must occur at the roof level.
FIGURE 1634 A Tubular Daylighting Device is an ideal product for bringing sunlight into any interior space. Image courtesy
Solatube International, Inc.
With various technologies used to capture daylight in
TDDs, the differences begin at the dome. Products can
range in technology from simple thermally formed, clear
plastic domes to more advanced systems that employ
optics to maximize light collection.
Transfer
From the dome level, daylight is captured and then
transferred through optical tubing, transporting daylight
from the rooftop aperture to the ceiling diffuser. TDD
systems use reflective tubing to duct daylight into
the buildings’ interior spaces. One benefit of TDDs, as
opposed to other daylighting methods, is the flexibility
of the tubing, with some models allowing angles
anywhere from 0° to 90° and the tube runs in excess
of 90' (27.4 m). Essentially, the goal of the tubing is to
maximize the ability of the light to travel down the tube,
while minimizing the light lost during transport.
Delivery
Diffusion is the point where all the components of
the system work together to bring the highest quality
daylight into the interior space. Varying lens technologies
are available for TDDs, from basic prismatic designs
to highly engineered Fresnel lenses. Figure 16-35
showcases a proprietary Fresnel diffuser that evenly
disperses large quantities of daylight. A Fresnel lens is
GOING
GREEN
327
Windows and Energy Loss (Continued)
Popular applications for Tubular Daylighting Devices
include single- and multifamily residential spaces,
schools and libraries, retail stores, restaurants, hotels,
office buildings, industrial properties (warehouses
and manufacturing), and health care and institutional
facilities. With the proper use of TDDs, spaces of any size
can be daylit for optimum lighting conditions, which is
demonstrated in Figure 16-36.
FIGURE 1635 This TDD diffuser brings in crystal clear daylight
and provides the highest light dispersion with a unique view of
the sky. Image courtesy Solatube International, Inc.
a type of lens originally developed for lighthouses. The
design allows the construction of lenses of large aperture
and short focal length without the weight and volume of
material required in conventional lens design. Compared
to earlier lenses, the Fresnel lens is much thinner, allowing
the passage of more light over much longer distances.
More advanced TDDs offer optical modulation
systems, allowing users to control light output, much
like they would with some electric light models. Some
devices can be integrated into lighting control systems,
while others offer a wall-mounted rocker switch,
allowing building inhabitants to modulate the daylight
themselves or set scene level controls.
Figure 16-38 shows how the symbols key to the
schedules. As an alternative method, you may consider
using a divided circle for the key. Place the letter D for
door or W for window above the dividing line and the
number of the door or window, using consecutive numbers, below the line, as shown:
W
1
W
2
D
1
D
2
The exact method of schedule presentation depends
on individual company standards, but most companies
use a similar format, and a consistent format should be
used throughout a set of drawings.
FIGURE 1636 The Beijing Science and Technology University
gymnasium installed 168 Tubular Daylighting Devices as
part of the first ever “Green Olympics.” Image courtesy Solatube
International, Inc.
Schedules are also used to identify finish materials used in different areas of the structure. For commercial buildings, the room is normally identified by
name, by room number, or by both name and room
number. Figure 16-39 shows a typical interior finish
schedule.
Door and window sizes can be placed on the floor
plan next to their symbols. This method, shown in
Figure 16-40, is used by some companies to save
time. Although this method is easy, it cannot be used
when specific data must be identified. The sizes are
the numbers next to the windows and doors in
Figure 16-40. The first two numbers indicate the
width. For example, 30 means 3'−0". The second two
numbers indicate the height. For example, 68 means
328
Architectural Drafting and Design
WINDOW SCHEDULE
8'-0 3/4 3 5'-0 7/8
1
4' 5'
W 2 N 5 CSM.
4'-0 3/4 3 5'-0 7/8
2
4' 36
W 2 N 3 CSM.
4'-0 3/4 3 3'-6 1/2
2
36 36
2 N 3 CSM.
3'-6 1/2 3 3'-6 1/2
2
6' 4'
G 64 SLDG.
6'-0 1/2 3 4'-0 1/2
1
DINING
5' 36
G 536 SLDG.
5'-0 1/2 3 3'-6 1/2
4
FAMILY
4' 36
G 436 SLDG.
4'-0 1/2 3 3'-6 1/2
1
4' 2'
A 41 AWN.
4'-0 1/2 3 2'-0 7/8
3
PAINT
W 4 N 5 CSM.
BROCADE
8' 5'
SPRAY
2
CEIL.
SMOOTH
VERIFY
TEXTURE
JOB BUILT
WALLS
PAINT
1' 5'
FLOOR
PAPER
A
B
C
D
E
F
G
H
J
ROOM
CONCRETE
QUAN.
TILE
MODEL
HARDWOOD
SIZE
CARPET
SYM
VINYL
ROUGH OPEN
INTERIOR FINISH SCHEDULE
ENTRY
FOYER
KITCHEN
LIVING
MSTR. BATH
BATH #2
MSTR. BED
A
BED #2
DOOR SCHEDULE
TYPE
BED #3
UTILITY
SYM
SIZE
QUAN.
1
2
3
4
5
6
3' 68
S.C. RP. METAL INSULATED
1
3' 68
S.C. FLUSH METAL INSULATED
2
2 8 68
S.C. SELF CLOSING
2
2 8 68
HOLLOW CORE
5
2 6 68
HOLLOW CORE
5
2 6 68
POCKET SLDG.
2
FIGURE 1639 Finish schedule.
6'−8". A 6040 window specification means the window
is 6'−0" wide by 4'−0" high, and a 2868 door means
the door is 2'−8" wide by 6'−8" high. Standard door
height is 6'−8". Some drafters use the same system in
a slightly different manner by presenting the sizes as
28 × 68, meaning 2'−8" wide by 6'−8" high; or by giving
B
FIGURE 1637 Window and door schedules.
20
6040
4
30
6040
B
3
2
1
68
A
28
A
68
A
2
3° X 4°
DOOR S
TY
QUAN.
SIZE
1
1
3°
B
1
6° X 4°
2
3
C
3
6° X 3°
3
1
D
2
3° X 4
4
2
FIGURE 1638 Method of keying windows and doors from the
floor plan to the schedules.
8
SIZE
6
30
WINDOW SCHE
QUAN.
28
FIGURE 1640 Simplified method of labeling doors and
windows.
Chapter 16: Floor Plan Symbols
CLEAR
ERP1
CLEAR/
RUBY
ERP2
EER6*
EER41
CLEAR
ERP3
EER3
AMBER
ERP4
EER8
NA 2'8"
329
ERP5
EER18
NA 2'8"
ERP6
EER42*
CLEAR
ERP7
EER44*
NA 6'6"
*Deadlocks on 2'8" 6-panel Embossed Doors must have a 2 3/8" backset.
**Deadlocks on 2'8" 6-panel Embossed Doors with half-glass lites must
have a 2 3/8" backset and a 2" rose.
FIGURE 1641 Excerpt from a page of a door catalog. Courtesy
Ceco Entry Systems, a United Dominion Company.
actual dimensions, such as 2'–8" × 6'–8". Metric sizes
are given in millimeters (mm) and vary as discussed
throughout this chapter. This simplified method of
identification is better suited for development housing
in which the manufacturer of doors, windows, and
other items is not specified in the plans. These details
are included in a description of materials or specification sheet for each individual house. The principal
reason for using this system is to reduce drafting time
by omitting schedules. The building contractor may
be required to submit alternative specifications to the
client so actual items are clarified.
When you are preparing a set of residential plans,
give specific details about doors and windows regarding
standard size, material, type of finish, energy efficiency,
and style. This information is available through vendors’
specifications. As an architectural drafter, you should
get copies of vendors’ specifications from manufacturers that have products available in your local area.
Figure 16-41 is a typical page from a door catalog that
shows styles and available sizes. Figure 16-42 is a page
from a window catalog that describes the sizes of a
particular product. Notice that specific information
is given for the rough opening (framing size), finish
size, and amount of glass. Vendors’ catalogs also provide construction details and actual specifications for
each product, as shown in Figure 16-43.
FIGURE 1642 Excerpt from a page of a window catalog.
Courtesy Pella Corporation.
FIGURE 1643 Vendor catalog detail. Courtesy Pella Corporation.
330
Architectural Drafting and Design
CADD APPLICATIONS
U.S. National CAD Standard for Schedules
The U.S. National CAD Standard recommends schedules
contain the parts shown in Figure 16-44 and described
as follows:
Heading—The heading identifies the main subject or
title of the schedule.
Mark Column—The first column on the left is the mark
column. The mark is the same as the key and can use
the same text, number, or symbol format described
earlier. Two mark columns can be used for additional
identification in large or wide schedules.
Item Description Column—This column provides the
name or identification of each item in the schedule.
Distinguishing Feature Column—Distinguishing
features are characteristics that describe the items
found in the schedule. There can be more than one
distinguishing feature column depending on the
complexity of the schedule.
Notes Column—This column is usually found on the
right side of the schedule and provides remarks, and
unique or special descriptions about items in the
schedule. A note can be descriptive words, complete
sentences, or key letters or numbers referring to or
FIGURE 1644 Schedule components recommended by the
U.S. National CAD Standard.
cross-referencing general notes on the drawings or in
specifications. It is often best to use the key letter or
number method to reference the notes to general notes
or specifications in order to save space on the schedules.
Schedules can be as simple or complex as needed.
The example shown in Figure 16-44 is a basic schedule
FIGURE 1645 The WALLS column is expanded to identify the required finish on the north (N), east (E),
south (S), and west (W) walls. The letters in the columns below refer to separate notes or specifications
describing the specific finish requirements.
FIGURE 1646 Schedules can be expanded further when additional information needs to be provided. The N, E, S, and W columns
expand to include material (MATL), finish (FIN), and color (CLR). The codes provided under each sub-identifier are correlated with the
Material Key, Finish Key, and Color Key.
Chapter 16: Floor Plan Symbols
331
CADD APPLICATIONS
format with single-column identifiers. You can expand
one or more columns as needed. For example, the
WALLS column in Figure 16-45 is expanded to identify
the required finish on the north (N), east (E), south (S),
and west (W) walls. The letters in the columns below
refer to separate notes or specifications describing the
specific finish requirements. Schedules can be expanded
further when additional information needs to be
provided. Figure 16-46 shows the N, E, S, and W columns
expanded to include material (MATL), finish (FIN), and
color (CLR). The codes provided under each sub-identifier
are correlated with the Material Key, Finish Key, and
Color Key shown in Figure 16-46.
USING CADD TO GENERATE SCHEDULES
The traditional method of creating CADD schedules
included the drafting of line work to create the schedule
grids, and using text commands to manually place text
within grid boxes to create the schedule of information.
This process is a tedious drafting task that creates a
schedule that must be manually coordinated, checked,
and updated as the project design is developed and
modified. Other methods of CADD schedule creation
include the use of spreadsheet software such as
Microsoft Excel. Schedules can be formatted with the
graphics and formulas within the spreadsheet program
then imported into the CADD application where they
become part of the construction documents. This process
also requires the manual coordination and management
of the information within the schedule to ensure that the
information is correct on the final documents.
Advanced CADD applications use object-oriented
CADD, which automates the task of schedule creation.
Object-oriented CADD refers to the CADD applications’
ability to create real-world building objects within a
building model. From these “real-world” objects, information can be obtained by querying the objects, thus
pulling out relative information and adding it dynamically
into a schedule format as shown in Figure 16-47.
This automatic method of schedule creation is
seamless in the development of information, and
provides accurate information. For example, if doors
are added to a CADD building model, any information
about those doors such as the door type, width, height,
and material can be queried by the schedule and
incorporated into the schedule table. Because of objectoriented CADD, any changes made to the doors, or the
addition or deletion of a door, is automatically tracked by
the schedule, constantly providing up-to-date, accurate
information about the design. ■
FIGURE 1647 Advanced CADD applications use object-oriented CADD, making the creation of a schedule automatic. Information
can be obtained by querying real-world objects, thus pulling out relative information and adding it dynamically into a schedule
format. Courtesy Ron Palma, 3D-DZYN.
332
Architectural Drafting and Design
CABINETS, FIXTURES, AND
APPLIANCES ON FLOOR PLANS
LAZY SUSAN
SINK WITH GARBAGE DISPOSAL
RANGE
RANGE
DW
RANGE
DW
PARALLEL LINES
UPPER CABINETS
HATCH LINES
UPPER CABINETS
FIGURE 1649 Alternative floor plan symbols for upper cabinets.
5-SHELVES
PICTORIAL
BRM
DISHWASHER
REFR
OBJECT LINE
UPPER CABINETS
UPPER CABINETS
In conjunction with kitchen cabinets, locate fixtures
such as sinks, butcher-block cutting board countertops,
lighting, and appliances such as the range, refrigerator,
dishwasher, trash compactor, and garbage disposal.
Figure 16-48 shows the floor plan view of kitchen cabinets, fixtures, and appliances. The upper cabinets are
generally shown with hidden (dashed) lines. However,
this practice can vary between architectural offices.
Some offices show upper cabinets using a solid line,
some use a series of parallel lines, and some hatch the
area where the upper cabinets are located. Each of these
options is shown in Figure 16-49. This textbook prefers
using the hidden line to represent upper cabinets.
The range should have a hood with a light and fan.
You should note how the fan vents. Some ranges do
not require a hood because they vent through the floor
or wall. Vent direction should be specified on the plan.
Some homes have a range cooktop with a built-in oven
or an oven and microwave unit. There are many options
available in kitchen designing. The width of the range
and refrigerator can vary between 30" and 54". Decide
on the size you want from a vendor’s catalog. Label
the garbage disposal with a note or with the abbreviation GD. Houses with septic tanks should review
DW
RANGE
PREFERRED HIDDEN
LINE UPPER CABINETS
Kitchen Floor Plans
L.S.
DW
DW
RANGE
Cabinets are found in kitchens, baths, dressing areas,
wardrobe closets, utility rooms, bars, and workshops.
Specialized cabinets such as desks or built-in dressers
can be found in bedrooms, kitchens, offices, and dens.
In general, the cabinets drawn on the floor plans are
built-in units that are permanent.
UPPER CABINETS
PANTRY W/
5-SHELVES
UPPER CABINETS
BASE CABINETS
RANGE
WITH
OVEN
L.S.
REFRIGERATOR
DASHED LINES
WHEN NOT A
BUILT-IN UNIT
OPTIONAL LAZY SUSAN
FLOOR PLAN REPRESENTATION
FIGURE 1648 Kitchen cabinets, fixtures, and appliances.
FIGURE 1650 Small kitchen pantry. Kitchen pantries can also
be big enough to walk into with a standard swing interior door.
Chapter 16: Floor Plan Symbols
333
manufacturer specifications to determine if a garbage
disposal is acceptable.
Pantries are popular and can be drawn as shown in
Figure 16-50. A pantry can also be designed to be part
broom closet and part shelves for storage, or it can be
large enough to walk into. The size depends on available
space and the needs of the home owner. Figure 16-51
shows a typical floor plan representation and cabinet
sizes for a kitchen layout.
mirror above. Bathroom sinks can be round, oval, rectangular, or other fashion shapes and designs, and they
are available in a variety of materials and sizes. Confirm
the desired sink specifications from manufacturer
catalogs.
The shower can be smaller or larger than the one
shown in Figure 16-52, depending on the manufacturer. Verify the size for a prefabricated shower unit
during the design process. Custom showers, built on
the job, can be any size or design. They are usually lined
with tile, marble, or other materials.
The common size of a prefabricated tub is 30" × 60",
but larger and smaller ones are available. A large variety of tub shapes and sizes are available from different
manufacturers.
Figure 16-53 shows a variety of products that are
available for use when something special is required in
a bathroom design. Verify the availability of products
and manufacturer specifications as you design and
draw the floor plan. Figure 16-54 shows the floor
plan representation of a 60" × 72" raised bathtub in a
NOTE: The Manual of Acts and Relevant Regulations, published for the Americans with Disabilities Act (ADA), specifies
dimensions and design for people with disabilities.
Bathroom Floor Plans
Bathroom cabinets and fixtures are shown in several
typical floor plan layouts in Figure 16-52. The vanity
can be any length, depending on the space available.
The term vanity, used in an architectural application, is
generally a bathroom cabinet containing a sink with a
VERIFY AVAILABLE SIZES
DOUBLE SINK
32" X 21"
32"
800mm
TC
GD
3"
15" RECOMMENDED
375 MINIMUM
mm
24"
600mm
LAZY SUSAN
20" - 30"Ø
LS
FOOD BAR, HEIGHT:
30" BAR CHAIR
36" TO 42" BAR STOOLS
DW
4'-6" LUMINATED LIGHT PANEL.
SEE ELECTRICAL PLAN.
DISHWASHER
12"
300mm
UPPER
CABINETS
24"
600mm
TRASH COMPACTOR
COOKTOP WITH HOOD
OR FLOOR EXHAUST FAN
FROM 30" TO 48" WIDE,
VENT ALL FANS TO OUTSIDE
300mm
VERIFY SIZES
AVAILABLE
30"
760mm
12"
REFR
PANTRY
BROOM
PANTRY VARIABLE SIZE
12" (300mm) MIN
3" (75mm) INCREMENTS
27"
675mm
36"
900mm
30"
750mm
BASE
CABINETS
REFRIGERATOR
36" WIDE MIN.
900mm
12"
300
mm
18"
450mm
PROVIDE 36" (900mm) MIN
CLEARANCE TO ISLANDS
LINE OF SOFFIT
24"
600mm
DOUBLE OVEN
OR MICRO OVER
OVEN
VERIFY FIXTURE AND APPLIANCE DIMENSIONS WITH PRODUCT SPECIFICATIONS.
VERIFY DESIGN AND DIMENSIONS FOR DISABLED ACCESS WITH THE MANUAL OF
ACTS AND RELEVANT REGULATIONS FOR THE AMERICANS WITH DISABILITIES ACT.
FIGURE 1651 Standard sizes of kitchen cabinets, fixtures, and appliances.
BUILT-IN OR FREESTANDING RANGE
AND OVEN WITH
HOOD AND FAN
M.C.
MIRRORS
KNEE
SPACE
4' X 30" HIGH COUNT.
6' X 3'
FIBERGL.
SPA
BENCH
S&P
LINEN
WARDROBE
SEAT
S & DBL. POLE
24" X 48" TEMP. FLAT
GLASS SKYLIGHT
STEP
5' X 42" CER.
TILE SHOWER
OVER 1/2" W.P.
GYP. BD. W/3
SHOWER HEADS
MEDICINE
CABINET
SYMBOL
8" STEPS
Architectural Drafting and Design
UP - 2
334
S&P
FULLY EQUIPPED BATHROOM WITH COMPARTMENTALIZED
WATER CLOSET, TUB AND SHOWER, DOUBLE VANITY,
BENCH, AND LINEN CLOSET
6Ø" X 72"
WHIRLPOOL
FIGURE 1654 Raised bathtub and solarium.
SMALL BATH
WITH SHOWER
SMALL BATH WITH
TUB OR TUB-SHOWER
COMBINATION
SMALL BATH OR
POWDER ROOM
18"Ø OR OVAL
SINK
STANDARD TOILET
WATER CLOSET SYMBOL
STANDARD SHOWER
SYMBOL 36" 36"
VANITY
22" DEEP
STANDARD TUB SYMBOL
5'–0" 2'–8"
solarium. Often, due to cost considerations, the space
available for bathrooms is minimal. Figure 16-55
shows some minimum sizes to consider. The Manual of
Acts and Relevant Regulations, published for the ADA,
specifies design and dimensions for people with disabilities. For example, wheelchair access requires up
to 60" (1524 mm) minimum width, depending on the
design used.
TYPICAL BATHROOM
Utility Room Floor Plans
FIGURE 1652 Floor plan symbols for layout of bathroom
cabinets and fixtures.
FIGURE 1653 Unique bathroom products. Courtesy Kohler Co.
The utility room can be a very important room in the
home, and its placement should be based on the family’s needs. The utility room is also called a laundry
room, and the location is often close to bedrooms
where most of the laundry items are located. The
design location of the utility room was discussed in
Chapter 10.
The symbols for the clothes washer, dryer, and
laundry tray are shown in Figure 16-56. The symbols
for clothes washers and dryers are drawn with dashed
lines if these items are not part of the construction
contract. The symbols for clothes washers and dryers
are generally drawn with solid lines if they are part
of the construction contract and included with the
completed home. Confirm the products included with
the completed home by referring to the description of
materials or the specifications. Laundry utilities can
be placed in a closet when only minimum space is
available, as shown in Figure 16-57. Stacked washer
and dryer products are available that occupy a smaller
space when design square footage is limited. Ironing
Chapter 16: Floor Plan Symbols
WATER CLOSET (TOILET)
5'
MIN
1524mm
18"
MIN
458mm
18"
MIN
458mm
BIDET
21"
MIN
534mm
24"
MIN
610mm
21"
MIN
534mm
15"
MIN
381mm
30"
MIN
762mm
24"
MIN
610mm
30"
MIN
762mm
335
URINAL
TOILET BIDET COMBINATION
18"
MIN
BATHTUB
24"
MIN
610mm
PEDESTAL SINK
SINK
30"
MIN
762mm
30"
MIN
534mm
21" MIN
534mm
30" 762mm
Recommended
30"
MIN
762mm
458mm
POWDER ROOM
HALF BATH
METRIC DIMENSIONS ARE PROVIDED FOR DESIGN REFERENCE.
VERIFY FIXTURE SIZES WITH PRODUCT SPECIFICATIONS.
VERIFY DESIGN AND DIMENSIONS FOR DISABLED ACCESS WITH THE MANUAL OF ACTS
AND RELEVANT REGULATIONS FOR THE AMERICANS WITH DISABILITIES ACT
AND LOCAL CODE REQUIREMENTS.
FIGURE 1655 Minimum bath spaces. All dimensions are IRC minimums.
The furnace and water heater are sometimes placed
together in a location central to the house. They can
be placed in a closet, as shown in Figure 16-59. These
5'-6"
MIN.
SHELF
D
D
W
FIGURE 1656 Washer, dryer, and laundry tray.
W
36" CLEAR
MIN.
boards can be built into the laundry room cabinets,
into the wall, or attached to the wall surface, as shown
in Figure 16-58. Provide a note to the electrician if
power is required to the unit, or provide an adjacent
electrical outlet. Electrical plans are described in
Chapter 19.
FIGURE 1657 Minimum washer and dryer space.
336
Architectural Drafting and Design
WALL
ROD
A SECTION
A
FIGURE 1658 Ironing boards.
3" MORE OR LESS
DEPENDING ON
JAMB DETAIL
5'-0"-6'-0"
SURFACE
MOUNT
BUILT-IN
1524-1828mm
SHELF & ROD W/
CENTER SUPPORT
24"
MIN.
600mm
SHELF
W/H
RECOMMENDED
CONFIRM WITH
MANUFACTURER
SPECIFICATIONS
AND CODES
FURN.
3Ø KW
36"
FIGURE 1660 Standard wardrobe closet and a walk-in
wardrobe.
PROVIDE
6" CLEARANCE
ALL AROUND
FIGURE 1659 Furnace and water heater.
utilities can also be placed in a separate room, in the
basement, or in the garage.
companies that customize the wardrobe closet to meet
the specific needs of family members.
Laundry Chutes on Floor Plans
When a laundry room is below the bedroom area, provide a chute from a convenient area near the bedrooms
through the ceiling and into a cabinet directly in the
laundry room. The cabinet should be above or next to
the clothes washer. Figure 16-61 shows a laundry chute
noted in the floor plan.
Wardrobes and Closets on Floor Plans
Wardrobes and closets, used for clothes and storage,
can be utilitarian in nature, or they can be large walk-in
areas with custom cabinets and a variety of functional
areas for garments and shoes. Bedroom closets should
be labeled CLOSET or WARDROBE. Other closets are
labeled to describe their use, such as ENTRY CLOSET,
LINEN CLOSET, or BROOM CLOSET. Wardrobe or
guest closets should be provided with a shelf and pole.
The shelf and pole can be drawn with a thin line to
represent the shelf and a center line to show the pole, as
in Figure 16-60. Some drafters use two dashed lines to
symbolize the shelf and pole. The pole is also referred
to as a rod. The pole is placed directly below the shelf
with enough space to pass the hanger through easily.
The height of the shelf can vary, depending on the
function of the closet. For example, a shelf height of
5'−0" (1500 mm) is fine for shirts, pants, and dresses.
A shelf height of 6'−0" (1800 mm) is preferred for long
gowns. Wardrobe closets designed for children have
shelf and rods at lower heights that vary depending on
the children’s ages. Some wardrobe closets are designed
with dual shelf-and-rod combinations or a shelf and rod
over a set of drawers. Closet packages are available from
LAUNDRY CHUTE TO
UTILITY BELOW-LINE
W/26 GA. METAL
LAUNDRY CHUTE FROM
CABINET ABOVE
W
FIGURE 1661 Laundry chute.
D
Chapter 16: Floor Plan Symbols
COMMON SIZES OF ARCHITECTURAL
FEATURES
Generally, all walls and edges of masonry are thick
lines, and all other lines are thin. Confirm the preferred
practice with your office or instructional standards.
The refrigerator, water heater, washer and dryer, dishwasher, trash compactor, built-in range/oven, and upper
cabinets can be drawn with hidden lines or solid thin
lines, depending on the specific office practice. Features
such as the refrigerator, water heater, washer and dryer,
dishwasher, trash compactor, and built-in range/oven
can be drawn with thin solid lines when they are part of
the construction contract and included in the finished
home. Confirm this with the description of materials
or specifications. Closet poles are 12" (300 mm) from
the back wall and are usually drawn using center lines.
Closet shelves are usually solid lines 15" (380 mm)
from the back wall.
The following features and product dimensions are
based on common sizes and recommended minimums.
Dimensions can vary depending on space available and
manufacturer specifications. Establish the final design
on the basis of the client’s needs and budget. Always
determine the exact dimensions during the design process by using manufacturer specifications, and then
confirm during construction on the basis of the actual
product. Metric values are given where appropriate.
Metric values are not provided for products that vary
depending on the manufacturer.
Room Component Dimensions
●
Exterior heated walls: 6" manual drafting or exact
dimensions with CADD (see Figure 16-3).
● Exterior unheated walls (garage/shop): 4" manual
drafting or exact dimensions with CADD (see
Figure 16-3).
● Interior walls and partitions: 4" manual drafting or
exact dimensions with CADD (see Figure 16-3).
● Interior plumbing below upper-floor water closet:
6" manual drafting or exact dimensions with CADD
(see Figure 16-3).
● Hallways: 36" (900 mm) minimum clearance.
● Entry hallways: 42" to 60" (1060 to 1500 mm) recommended minimum.
● Bedroom closets: 24" (600 mm) minimum depth;
48" (1200 mm) minimum width.
● Linen closets: 14" to 24" (350 to 600 mm) deep (not
over 30" [760 mm]).
337
●
Base cabinets: 24" (600 mm) deep; 15" to 18" (380
to 450 mm) deep bar; 24" (600 mm) minimum deep
island with 12" (300 mm) minimum at each side of
cooktop; 36" (900 mm) minimum from island to
adjacent cabinet for passage, 48" (1200 mm) is better
on sides with an appliance.
● Upper cabinets: 12" (300 mm) deep.
● Washer/dryer space: 36" (900 mm) deep; 5'−6"
(1675 mm) minimum width.
● Stairways: 36" (900 mm) minimum width; 10 1/2" to
12" (260 to 300 mm) tread. See examples later in this
chapter.
● Fireplace: See examples later in this chapter.
Plumbing Fixture Dimensions
Kitchen sink: double, 32" × 21"; triple, 42" × 21".
Confirm manufacturer style and specifications.
● Vegetable sink and/or bar sink: 16" × 16" or 16" ×
21". Confirm manufacturer style and specifications.
● Laundry sink: 21" × 21". Confirm manufacturer style
and specifications.
● Bathroom sink: 19" × 16", oval. Provide 9" from edge
to wall and about 12" (300 mm) minimum between
two sinks; 36" (900 mm) minimum width. Other
sink shapes and styles are available. Confirm manufacturer style and specifications.
● Water closet space: 30" (760 mm) minimum width;
24" (600 mm) clearance in front. A water closet is a
toilet or a room equipped with a toilet. The abbreviation WC can be used.
● Tub: 32" × 60" or 32" × 72". Larger prefabricated
tubs and tub–shower combinations are available.
Confirm manufacturer style and specifications for
prefabricated tubs and tub–shower combinations.
● Shower: 36" square; 42" square; or combinations of
36", 42", 48", and 60" for prefabricated showers. A
custom ceramic tile or marble shower can have any
desired specifications. Confirm manufacturer style
and specifications for prefabricated showers.
● Washer and dryer: 2'−4" square each (approximately).
●
Appliance Dimensions
●
Forced-air furnace equipment: Gas, 18" square minimum with 6" space all around. The furnace cannot
go under stairs. Electric, 24" × 30" with same space
requirements as gas. Always confirm exact size and
installation specifications with manufacturer.
338
●
Water heater: Gas, 18" to 22" diameter. The gas
water heater cannot go under stairs. Always confirm exact size and installation specifications with
manufacturer.
● Refrigerator: 36" wide space, and approximately 27"
deep. Provide 4" from wall, and 1" from adjacent
base cabinet. Larger refrigerators are common and
can be built into the cabinetry. Confirm manufacturer style and specifications.
● Stove and cooktop: 30" × 21" deep. Other sizes and
styles are available. Confirm manufacturer style and
specifications.
● Built-in oven: 27" × 24" deep. Other sizes and
styles are available. Confirm manufacturer style and
specifications.
● Dishwasher: 24" × 24". Place the dishwasher near the
kitchen sink for precleaning and near upper cabinet
for ease of putting away dishes.
● Trash compactor: 15" × 24" deep. Place the trash
compactor near the kitchen sink, and away from the
stove. Other sizes and styles are available. Confirm
manufacturer style and specifications.
● Broom closet and pantry: 12" (300 mm) minimum
× 24" (600 mm) deep; width increasing by 3"
increments.
● Desk: 30" × 24" (760 × 600 mm) deep (minimum);
out of main work triangle.
● Built-in vacuum: 24" to 30" diameter.
Door Dimensions
Entry: 36" × 6'−8"; 42" × 8'.
● Sliders or French: 5', 6', 8' (double); 9', 10' (triple);
12' (four-panel).
● Garage, utility, kitchen, and bedrooms on custom
houses: 2'−8", 2'−10", or 3'−0".
● Bedrooms: 2'−6" or 2'−8".
● Closets and wardrobes: 2'−4", 2'−6", 2'−8", 2'−10",
3'−0", 4'−0", 5'−0", 6'−0", 7'−0", 8'−0", 9'−0",
10'−0", 11'−0", or 12'−0" depending on the size of
the closet or wardrobe and the type of door used.
● Bathrooms: 2'−4" or 2'−6".
● Garage car door: 8' × 7', 9' × 8', 16' × 7', or 18 × 7'.
● Garage people door: 2'−8", 2'−10", or 3'−0".
●
Window Styles and Dimensions
The following factors should be considered because
they can influence window sizes:
Architectural Drafting and Design
●
Architectural style. For example, contemporary
style often uses large fixed windows, but traditional
style often uses smaller double-hung or casement
windows.
● Amount of light desired.
● Desired appearance. For example, compare the look
of one 8' to 10' wide window versus four to six 2'
wide windows.
● Type of window. For example, aluminum-frame windows are commonly manufactured in nominal even
measurements such as 12", 24", 36", and 48" modules. Wood-frame window dimensions vary, depending on the manufacturer. Also, sliding and fixed
windows are often sized differently from casement
and double-hung windows. Dimensions of these
types of windows must be confirmed and based on
the manufacturer’s specifications.
● Window location and function. For example, bedroom
windows require emergency egress as explained in
Chapter 9. When the kitchen window is placed in a
cabinet wall, its height must be selected to maintain
the window at or above the base cabinet height.
❍ Living, family: 8' to 10' suggested common width.
❍ Dining, den: 6' to 8' suggested common width.
❍ Bedrooms: 4' to 6' suggested common width.
❍ Kitchens: 3' to 5' suggested common width.
❍ Bathrooms: 2' to 3' suggested common width.
❍ Sliding: 4', 5', 6', 8', 10', or 12' suggested common
width..
❍ Single-hung: 24", 30", 36", or 42". Confirm manufacturer sizes and specifications.
❍ Casement: Same as sliding. Confirm manufacturer
sizes and specifications.
❍ Fixed and awning: 24", 30", 36", 42", or 48".
❍ Fixed and sliding: 24", 30", 36", 42", or 48".
❍ Fixed picture: 4', 5', 6', or 8' suggested common
width.
❍ Bay: 8' to 10' total; sides, 18" to 24" wide, with 30°
to 45º sides. Bay and bow windows are generally
custom and can be designed to suit specific architectural applications.
NOTE: This is a review of code requirements described in
Chapter 9 of this textbook.
ACCESSIBLE ROUTES
The exterior access, or front door, cannot be located in
a bedroom. At least one route is required to connect all
spaces that are part of the dwelling unit. If only one route
Chapter 16: Floor Plan Symbols
is provided, it cannot pass through a bathroom, closet,
or similar space. The access route is required to have a
minimum width of 36" (914 mm) except at doors. Vertical
changes in floor height cannot exceed 1/4" (6.4 mm).
Changes in floor level up to 1/2" (13 mm) are allowed if a
bevel with a slope not exceeding 1:2 is provided. Ramps
cannot have a slope greater than 1:20. Floor surfaces of
a turning space are allowed to have a slope no steeper
than 1:48.
MEANS OF EGRESS
Residences are required to have a clear passage from all levels
of the home to a door that leads directly to the outside, without requiring travel through a garage.
ACCESS DOORS
Each residence must have a minimum of one door that is
at least 32" (813 mm) wide measured between the face of
the door when open 90° and the stop. The minimum clear
height of the door opening must be 78" (1981 mm) from the
top of the threshold to the bottom of the stop. The designer
can determine all other door sizes based on personal preferences or the client’s needs. The IRC allows the main entry
door to be 32" (813 mm) wide, but common practice is
to provide a 36" (900 mm) or larger door for an inviting
entrance.
339
A shower or tub equipped with a shower head must
also have a minimum ceiling height of 6'–8" (2032 mm)
above a minimum area of 30" × 30" (762 × 762 mm) at the
shower head.
FLOOR PLAN MATERIALS
Finish materials used in construction can be identified on the floor plan with notes, characteristic
symbols, or key symbols that relate to a finish material schedule. The key symbol is also placed on the
finish schedule next to the identification of the type
of finish needed at the given location on the floor
plan. Finish schedules can also be set up on a roomby-room basis. When flooring finish is identified,
the easiest method is to label the material directly
under room designation as shown in Figure 16-62.
Other methods include using representative material
symbols and a note to describe the finish materials as
shown in Figure 16-63.
CARPET
VINYL
TILE
FIGURE 1662 Room labels with floor finish material noted.
EMERGENCY EGRESS OPENINGS
Windows are a major consideration in designing exits.
Emergency egress is required in basements, habitable attics,
and every sleeping room. When basements contain one or
more sleeping rooms, emergency egress and rescue openings are required to be in each sleeping room. Escape can be
made through a door or window that opens directly into a
public street, alley, yard, or exit court. The emergency escape
must be operable from the inside without the use of any keys
or tools. The sill of all emergency escape bedroom windows
must be within 44" (1118 mm) of the floor. Windows used for
emergency egress must have a minimum net clear area of 5.7
sq ft (0.530 m2). Grade floor opening size can be reduced to
5.0 sq ft (0.465 m2). The net clear opening area must have a
minimum width of 20" (508 mm) and a minimum height of
24" (559 mm).
SLATE
TILE
BATHROOM REQUIREMENTS
A distance of 21" (533 mm) is required in front of a toilet to
any obstruction. A minimum clearance of 21" (533 mm) is
also required in front of a bathroom sink to any obstruction, and a minimum distance of 24" (610 mm) is required
in front of a shower. These sizes can often affect the layout
of a small bathroom, but are rarely a problem in a custom
home.
FIGURE 1663 Finish material symbols.
340
Architectural Drafting and Design
CADD APPLICATIONS
Placing Material Symbols with CADD
Floor plans, sections, elevations, and interior elevations often
include the description of finish materials to indicate the
type of material used within the building. In Figure 16-64,
material patterns are displayed in the floor plan to represent
wood decking, wood flooring, floor tile, and counter tile.
CADD programs include tools to show these finish
materials directly on a CADD drawing. These material
tools are often referred to as Hatch or Fill Patterns.
Material patterns are available in a variety of symbolic
patterns, which can be applied to plan, section, and
elevation drawings. Many additional patterns can also
be found on the Internet or from manufacturer Web
sites for use in your CADD program. ■
FIGURE 1664 A CADD drawing of a floor plan with material finishes delineated to represent wood decking, wood flooring, floor tile,
and counter tile.
Chapter 16: Floor Plan Symbols
341
calculation. The calculations can be soft or hard conversion. A soft metric conversion is the preferred metric
construction standard that rounds off dimensions to
convenient metric modules. For example, stairs 36"
wide are 900 mm when soft conversion is used. Inches
are converted to millimeters with the formula 25.4 ×
inches = mm. So 25.4 × 36" = 914.4 mm. This is
rounded off using soft conversion to 900 mm, because
900 is an even metric module that is commonly used
in construction. A hard metric conversion is calculated
close to or exactly the same as the inch equivalent. A
hard conversion of 36" is 25.4 × 36" = 914.4, and is
rounded to 914 mm. This formula can be used in a
situation where the code requires a guardrail 36" high,
because 914 mm is safely close to 36".
The design of a multistory home is often made complex by the need to plan stairs. Figure 16-65 shows
several common flights of stairs. Stairs should be conveniently located for easy access. Stair components
and construction are shown in plan view and sectional
view in Figure 16-66. Review Chapter 9 for stair code
Structural Materials on Floor Plans
Structural materials are identified on floor plans with
notes and symbols or on framing plans. This is discussed in detail in Chapter 32.
STAIR PLANNING AND FLOOR
PLAN REPRESENTATION
This section covers the design and drafting of the floor
plan representation of stairs. The discussion gives you
basic information about stair design and codes and
shows you different types of stairs and how they are
drawn. Review Chapter 9 for additional code requirements. You will also be able to make calculations for
placement of stairs on the floor plan. When it is time
for you to learn about drawing stair sections and details,
Chapter 39 provides you with complete information on
stair construction and layout.
Metric dimensions are given for design reference.
Metric values vary, depending on the method of
LANDING
UP
UP
UP
TREADS
RISER
STRAIGHT
FLIGHT OR
STRAIGHT PLATFORM
U-SHAPE
UP
6" MIN
UP
UP
WINDERS
L-SHAPE
FIGURE 1665 Stair types.
SPIRAL
342
Architectural Drafting and Design
34" HIGH HANDRAIL
DN 14R
34" HIGH HANDRAIL
36" HIGH
GUARDRAIL
UPPER FLOOR PLAN
34" HIGH HANDRAIL
STORAGE
CLOSET
UP 14R
34" HIGH HANDRAIL
5/8" TYPE 'X' GYPSUM
AT ALL USABLE STORAGE
LOWER FLOOR PLAN
STAIRWELL OPENING
RISER
RISERS
PLATE
SHOE
TREAD
SOLID BLOCK
FLOOR JOIST
HEADER
NAILER
5/8" TYPE 'X'
GYPSUM
HEADER
STUDS
SILL
ANGLE 30˚-35˚
11'-4 1/2"
TOTAL RUN
STAIR SECTION
A
SOLID BLOCK
TOP PLATES
STRINGERS
7 3/4"
7" MIN
8 1/4"
MAX.
B
34" MIN.
38" MAX.
OF
E
N
I
L
10 1/2"
9" MIN
12" MAX
NOSING
IL
8'- 11 5/8"
TOTAL RISE
TREAD
N
HA
A
DR
8'- 1 1/8"
RISER
RUN
6'-8" MIN.
HEADER
NOTE: THE DIMENSIONS PROVIDED IN THIS
EXAMPLE ARE FOR THE STAIR DESIGNED FOR
THE HOUSE DISPLAYED THROUGHOUT THIS TEXT.
MINIMUM AND MAXIMUM DIMENSIONS ARE ALSO
GIVEN FOR REFERENCE WHERE APPROPRIATE.
GENERAL CONSTRUCTION MATERIAL NAMES ARE
GIVEN HERE FOR REFERENCE ONLY. ACTUAL
SIZES AND SPECIFICATIONS ARE GIVEN IN
CHAPTER 39 “STAIR CONSTRUCTION AND LAYOUT.”
FIGURE 1666 Stair floor plan representations and stair cross section with stair components and minimum requirements labeled.
This stair is also the stair design that is used in the sample architectural design displayed throughout this textbook. (A) Full stair
section. (B) Partial section with the tread and riser terminology.
Chapter 16: Floor Plan Symbols
requirements. Properly designed stairs have several
important characteristics, such as the following:
●
Minimum stair width is 36" (900 mm) but more,
such as 48" to 60" (1200 to 1500 mm), is preferred if
space is available.
● Stair tread depth should be 10" to 12" (250 to 300
mm) with 10" (254 mm) minimum.
● Individual risers can range between 6" and 9" (150
and 220 mm) in height. Risers should not vary more
than 3/8" (10 mm). A comfortable riser height is
7 1/4".
● The stair angle should be between 30° and 35° when
measured from the floor (see Figure 16-66).
● Landings at the top and bottom of stairs should be at
least equal in depth to the width of the stairs.
● A clear height of 6'–8" is the minimum amount of
headroom required for the length of the stairs. A
height of 7'–0" is preferred.
● The stairs shall have a handrail that measures between
34" and 38" (860 and 965 mm) above the nosing, as
shown in Figure 16-66.
● Guardrails at landings above stairs, at balconies, at
lofts, or at any area above another floor shall be at
least 36" (914 mm) high above the floor and have
openings no greater than 4" (102 mm).
NOTE: Stair Design Calculations
The stair design shown in Figure 16-66 meets code requirements with 7 3/4" rise and 10 1/2" run. This is the same
stair used in the model house in the chapters throughout
this textbook. In addition to minimum and maximum code
requirements, other stair design criteria are used by architectural professionals. These stair design formulas can be
used as a guide to creating ideal stairs. The actual stair
design depends on the available space and must be within
minimum and maximum code requirements. As an architectural designer, you need to carefully balance the available
space with the minimum and maximum stair design requirements. This balance is often difficult to accomplish.
A sample stair design formula is 2R + T = 24" to 25" where
R = riser dimension and T = tread dimension, without nosing.
If the stair shown in Figure 16-66 has 7 3/4" risers and 10
1/2" treads, the formula 2 × 7 3/4" + 10 1/2" = 26" puts this
stair design over the 25" recommended maximum. This is
acceptable because it is within code requirements, but stairs
designed with risers closer to 7 1/4" are more comfortable.
Another stair design formula is R + T = 17" to 17 1/2". The
stair design in Figure 16-66 is 7 3/4" + 10 1/2" = 18 1/4". This
also is beyond the acceptable boundaries recommended by
this formula, but inside the code requirements.
343
An additional formula can be used to check the acceptability of the stair design. This formula is R × T = 70" to 75".
The stair in Figure 16-66 is 7 3/4" × 10 1/2" = 81 3/8", which
is also beyond the guidelines recommended by the formula.
The example stair meets code requirements but is not an
ideal stair design. When space conditions cause you to design
a stair that is less than perfect, then you need to decide if
additional space should be designed into the building to help
create better stairs. Sometimes this is possible, but in many
cases the economics force you to limit square footage. These
are issues that should be discussed with your clients if the
home is a custom design. Even if you end up designing less
than perfect stairs, you must be sure to be within the code
requirements. Review Chapter 9 for code requirements. A
final check of stair design can be found when you draw the
stair section after studying Chapter 39. Stair characteristics,
stair calculation, construction, and drawing stair sections are
discussed in Chapter 39.
Handrails are placed at a blank wall along a flight
of stairs to be used for support. Handrails should run
the entire length of the stairs, even though the stairs
are enclosed between two walls. Stairs with more than
three risers require handrails. Handrails should be
between 34" and 38" (860 and 965 mm) high above
the nosing with 34" preferred. Guardrails are placed
where there is no protective wall. They serve the dual
purpose of protecting people from falling off the edge
of the stairs and providing a rail for support. Stairwells,
or stair openings in the floor, should be enclosed with
strong railings extending 6" (150 mm) past the edge of
the first step. Guardrails should be 36" (915 mm) high
from the floor and have no opening over 4" (100 mm)
between rails.
Stairs on Floor Plans
Stairs are shown on floor plans by the width of the tread,
the direction and number of risers, and the lengths
of handrails or guardrails. Abbreviations used are DN
(down), UP (up), and R (risers). A note of 14R means
there are 14 risers in the flight of stairs.
Stair layouts depend on the amount of space available, comfort, and code requirements. Use the following
suggestions as you create the floor plan stair layout:
●
There is always one less run than rise, where the run
is the horizontal distance of a set of steps or the measurement describing the depth of one step, and the
rise is the amount of vertical distance between one
tread and another (see Figure 16-66).
● The average set of stairs has 14 to 15 risers between
two floors.
344
Architectural Drafting and Design
●
To calculate the length of stairs, multiply the length
of a tread by the number of runs. For example, stairs
with 14 risers have 13 runs. If each individual run
is 10" (254 mm), then 10" × 13R = 130" (254 ×
13R = 3302 mm), or 10'−10" is the total run.
● If you use the stairs in Figure 16-66 as an example,
the total run is 11'−4 1/2" (346.1 mm). This is
calculated as: 13R × 10 1/2" = 11'−4 1/2" (13R ×
266.7 = 3467.1 mm).
● Keep in mind that landings take up more space, and
they should be as deep as the stairs are wide. For
example, if a 36" (900 mm) wide stairway must have
a landing, the landing should measure 36" × 36"
(900 × 900 mm) minimum.
36"
Figure 16-67 shows a common straight stair layout
with a wall on one side and a guardrail on the other side.
Figure 16-68 shows a flight of stairs with guardrails all
around at the top level and a handrail running down
the stairs. Figure 16-69 shows stairs between two walls.
Notice also that the stairs are drawn broken with a long
break line at approximately midheight if you are looking at a stair that is rising or intersecting up and down
stairs. If the stair is going down, as in Figure 16-67,
the break line can be omitted and the stairs drawn the
full extent. Figure 16-70 shows stacked stairs with one
flight going up and the other down. This situation is
common when access from the main floor to both the
second floor and basement or second and third floors is
designed for the same area.
DN 14R
5/8" TYPE 'X' GYPSUM
UNDER STAIRS @ ALL
USABLE STORAGE
DN 14R
34" HANDRAIL
FIGURE 1669 Stairs between two walls.
34" HANDRAIL
UP 14R
DN 14R
34" HANDRAIL
FIGURE 1670 Stairs up and down in the same area.
Stairs with winders and spiral stairs can be used
to conserve space. Winders are used to turn a corner
instead of having a landing. Tapered winder treads
must not be any smaller than 6" (150 mm). See
Chapter 9 for minimum requirements. Spiral stairs
and custom winding stairs can be manufactured in
several designs. Figure 16-71 shows the plan view of
winder and spiral stairs.
A sunken or raised living room or family room is
often a popular design feature. When a room is either
34" RAIL
USED AS FIRE PROTECTION
UNDER STAIRS
36" GUARDRAIL
U
FIGURE 1667 Stairs with a wall on one side and a guardrail
on the other.
5/8" TYPE 'X' GYPSUM
UNDER STAIRS @ ALL
USABLE STORAGE
P 15R
36" GUARDRAIL
34" HANDRAIL
36" MIN. RAIL
FIGURE 1668 Stairs with guardrails all around.
UP 14R
SPIRAL STAIRS
DN 14R
34" HANDRAIL
STAIRS WITH WINDERS
FIGURE 1671 Winder and spiral stairs.
Chapter 16: Floor Plan Symbols
345
LIVING
DINING
DOWN
STEPS
36" GUARDRAIL
UP 2
1 STEP
FIGURE 1672 Sunken or raised rooms.
sunken or raised, there is at least one step into the
room. The steps are noted with an arrow, as shown
in Figure 16-72. The few steps up or down do not
require a handrail unless the floor levels are more
than 30" (760 mm) apart. The guardrail shown in
Figure 16-72 is for decoration only in this case.
The ADA specifies the use of a ramp for wheelchair access. The ramp should have a slope of 1:12
for 30" (762 mm) maximum rise and 30' (9 m) of
horizontal run.
HALLWAYS ON FLOOR PLANS
Hallways in buildings are designed to provide access to
various areas. Hallways can be long or short, depending
on the area being accessed. The length and number of
hallways should be kept to a minimum because they
use up valuable living space. Sometimes hallways are a
unique part of the design, such as an art gallery or a hallway with a sitting alcove, providing more than simple
access to rooms.
CADD APPLICATIONS
Designing and Drawing Stairs with CADD
Standard 2D CADD programs used to draft lines can
be used in a floor plan stair layout. This can be done by
drawing the riser lines, copying or offsetting the risers
a specified tread depth distance, and then drawing the
stair edges to quickly create a 2D stair.
Many specialized CADD programs for creating buildings
and architecture include stair-generation tools. On many
of these tools, easy-to-use stair design routines allow the
quick generation of straight, U-shaped, L-shaped, spiral, and
custom stair designs. Often the use of parametric design
tools allows you to enter design data for the stair such as:
•
•
•
•
•
•
Floor-to-floor height.
Tread depth.
Riser height.
Stair length.
Railing type.
Stringer specifications.
The term parametric refers to “smart” relationships
between the parts of the stair such as the treads, risers,
floor-to-floor height, landing, stringers, and stair width.
When the values of these stair parts are adjusted,
the other parts work with or react to the value
modifications and make changes automatically based
on set parameters or rules. For example, based on
design rules used in a parametric stair, a floor-to-floor
value change causes the number of risers and treads to
adjust. These design rules can be developed to match
local building codes. Parametric stairs often give you
the ability to create a 2D stair for plan view drawings,
elevations, and sections, and 3D stairs for modeling
and visualization views. Figure 16-73 provides an
example of a parametric stair created in 2D plan view
and automatically generated into the 3D model view
stair. ■
346
Architectural Drafting and Design
CADD APPLICATIONS
UP
FIGURE 1673 Parametric stairs can be automatically drawn based on specifications that you provide. This figure provides an example of a parametric stair created in 2D plan view and automatically generated into the 3D model view stair. Courtesy Ron Palma, 3D-DZYN.
Hallways should be 36" (900 mm) minimum width.
Hallways in custom homes can be as wide as 48" to
60" (1200 to 1500 mm) depending on the available
space and design requirements. Hallways leading from
a grand foyer entrance can be wider, depending on the
custom architectural design. Metric dimensions vary,
depending on hard or soft conversion as previously
discussed.
FIREPLACES ON FLOOR PLANS
Fireplaces are commonly constructed using masonry,
but prefabricated fireplaces made of steel can be
installed in a masonry or wood-frame structure.
Masonry fireplaces are constructed of brick or stone
and the firebox is constructed with fire brick. Fire
brick is brick made of refractory ceramic material that
resists high temperatures. The masonry fireplace floor
plan representation uses section lines, also called hatch
lines, placed at a 30º to 45º angle. Figure 16-74 shows
common terminology associated with a masonry
fireplace. The dimensions shown on the fireplace floor
plan symbol in Figure 16-74 are recommended minimums. Figure 16-75 shows several typical fireplace
floor plan representations. Common fireplace opening
sizes in inches are shown in the following table:
Opening Width
Opening Height
Unit Depth
36"
24"
22"
40"
27"
22"
48"
30"
25"
60"
33"
25"
Steel Fireplaces
Fireplace fireboxes made of steel are available from
various manufacturers. The floor plan representation
of a steel fireplace framed in masonry is shown in
Figure 16-76. These prefabricated fireplaces are popular
because of their increased efficiency. Some units add to
347
4'-8" TO 5'-4"
8" MIN.
15°
MASONRY
36"
12" UNLINED
8" LINED
Chapter 16: Floor Plan Symbols
FIRE BRICK
4"
18"
MIN
FIGURE 1676 Manufactured firebox framed in masonry.
SCREENED CLOSABLE
VENT WITHIN 24"
FLOOR LEVEL OR
RAISED HEARTH
4"
4'-0"
12"
2'-0"
3'-0"
FIGURE 1674 Single masonry common and minimum
fireplace dimensions, not generally shown on the plan.
SEE MFG INSTALLATION
SPECIFICATIONS. VENT-FREE
GAS FIREPLACE.
NOTE MAY ALSO READ:
DIRECT-VENT GAS, SELF-VENTING
GAS, OR VENT-FREE GAS FIREPLACE
FIGURE 1677 Manufactured firebox in wood frame.
BACK-TO-BACK DOUBLE
CORNER
FIREBOX
FIREPLACE
STRUCTURE
DIMENSION A
OPENING SIZE
IN INCHES
DOUBLE FACED
SEE-THROUGH
THREE FACED
SWEDISH
FIGURE 1675 Floor plan representations of a typical masonry
fireplace.
their efficiency with fans that are used to circulate air
around the firebox and into the room.
There are also insulated fireplace units made of steel
that can be used with wood-framed chimneys. These
units are often referred to as zero-clearance fireplaces,
where the insulated metal fireplace unit and flue can be
placed next to or with a small air space from a woodframed structure. Verify building code clearances and
vendor specifications before designing a home with a
zero-clearance fireplace. The popularity of steel fireplaces has increased, due to their low construction
cost compared to masonry fireplace and chimney
construction (see Figure 16-77). Figure 16-78 shows
some common sizes of available fireplace units.
28
32
36
40
48
60
FACE BRICK
A
HEARTH
FIGURE 1678 Prefabricated fireplace opening sizes. Courtesy
Heatilator, Inc.
Direct-Vent, Self-Venting, and Vent-Free
Gas Fireplaces
Where environmental restrictions on wood-burning
fireplaces exist, manufactured direct-vent, self-venting,
and vent-free gas fireplaces are available for the architectural design. These fireplaces provide a gas fire
around realistic-looking ceramic logs, without the mess
and labor involved in burning wood. These systems
are commonly designed with safety features such as
control panels, thermostatic controls, and remote controls. These fireplaces do not affect indoor air quality,
which makes them a good choice for energy-efficient
construction. They are also economical, making them
348
Architectural Drafting and Design
a consideration when the cost of a masonry fireplace is
not feasible.
Direct-vent fireplace models have a chimney that is
vented through the roof or out the wall and extended
above the roof exposed or in a framed enclosure.
Direct-vent fireplaces are generally sealed-combustion
heaters. The doors open only for maintenance. The
exhaust gases exit through the center, and combustion air is drawn into the fireplace through the outer
chamber. The air is heated in passages behind the metal
firebox, and the room air does not come into contact
with the flames. Heat radiates through the glass doors
and is forced by convection or fans around the firebox and into the room. The self-venting units can be
vented directly out the wall behind the fireplace. The
vent-free fireplaces are installed without a flue. Any
zero-clearance, wood-burning, direct-vent, self-venting,
or vent-free gas fireplace must be designed, installed,
operated, and maintained in strict compliance with
manufacturer specifications and building and fire code
specifications and regulations. Information about possible code restrictions and installation requirements
should be established with local building and fire officials before specifying these on the design. Automatic
switches might be specified to allow shut-off if the unit
overheats. Improper installation can cause an explosion,
carbon monoxide poisoning, or excessive condensation inside the building. Confirm the manufacturer
specifications and provide the model number and other
specific information next to the fireplace symbol on the
floor plan or in a general note. The gas supply should
also be shown with a symbol and a note, similar to the
example in Figure 16-79.
CLEANOUT ACCESS
C.O.
FIGURE 1680 Fireplace cleanout.
Fireplace Cleanout
Provide a cleanout when you can have easy access to
the base of the fireplace. The cleanout provides a small
door in the floor of the firebox that allows ashes to be
dumped into a hollow cavity built into the fireplace
below the floor. Access to the fireplace cavity to remove
the stored ashes is provided from the basement or outside the house. Figure 16-80 shows a fireplace cleanout
noted in the plan view.
Wood Storage
Fireplace wood can be stored near the fireplace. A
special room or an area in the garage adjacent to the
fireplace can be ideal for wood storage. A wood storage
compartment built into the masonry next to a fireplace
opening can also be provided for storing a small amount
of wood. The floor plan representation of such a wood
storage box is shown in Figure 16-81.
Combustion Air
Gas-Burning Fireplace
Natural gas can be provided to the fireplace, either for
starting the wood fire or for fuel to provide flames on
artificial logs. The gas supply should be noted on the
floor plan, as shown in Figure 16-79.
Building codes require that combustion air be provided
to the fireplace. Combustion air is outside air supplied in sufficient quantity for fuel combustion. The
air is supplied through a screened duct that is built by
masons from the outside into the fireplace combustion
chamber. By providing outside air, this venting device
prevents the fireplace from using the heated air from the
GAS
WOOD
STORAGE
4 X 1Ø HDR
8"
14" RAISED HEARTH
12" HIGH HEARTH
FIGURE 1679 Gas supply to fireplace.
FIGURE 1681 Wood storage.
24"±
Chapter 16: Floor Plan Symbols
349
room, thus maintaining indoor oxygen levels and keeping heated air from going up the chimney. Always confirm combustion air requirements and specifications
with building codes. A note should be placed on the
floor plan next to the fireplace that states the following:
PROVIDE OUTSIDE COMBUSTION AIR TO WITHIN 24", or
PROVIDE SCREENED CLOSABLE VENT TO OUTSIDE AIR
WITHIN 24" OF FIREBOX.
Built-In Masonry Barbecue
When a home has a fireplace in a room next to the
dining room, nook, or kitchen, the masonry structure
can also incorporate a built-in barbecue. The floor plan
representation for a barbecue is shown in Figure 16-82.
A built-in barbecue can be purchased as a prefabricated
unit that is set into the masonry structure surrounding
the fireplace. There can be a gas or electric supply to the
barbecue as a source of heat for cooking. As an alternative, the barbecue unit can be built into the exterior
structure of a fireplace for outdoor cooking. The barbecue can also be installed separately from a fireplace and
located in an outside cooking area.
Multilevel Fireplaces
In two- or three-story homes, it is common to have
a fireplace structure that is constructed up through
all levels with a chimney exiting at the roof. In this
situation, a fireplace can be placed at each floor if the
design is appropriate. The fireplace on the first floor is
drawn similar to the example in Figure 16-74, except
additional width is needed for the flues of all stacked
fireplaces to extend to the top of the chimney. A flue
is a heat-resistant, incombustible enclosed passageway
in a chimney to carry combustion products from the
fireplace. The flue lining within a chimney is made
of square, rectangular, or round fire brick or fire clay
products or round double- or triple-insulated steel for
zero-clearance fireplaces. There must be a separate flue
for each fireplace. This means that the fireplace structure and the chimney need to be sized large enough to
accommodate the fireplaces and the flues running up in
the same structure. Figure 16-83 shows the floor plan
drawing of a fireplace at the main floor and the second
floor, and the chimney beyond the second floor. If a
third-floor fireplace is used, an additional flue is added
Electric Fireplaces
4"-8"
Electric fireplaces can provide the realism and ambience
of conventional wood-burning and gas fireplaces with
less expensive installation requirements and maintenance. These units require electrical wiring with a 110
or 220 volt outlet, depending on the unit specifications.
They are generally zero-clearance, meaning they can be
installed directly against wood framing. There is no ventilation required, so electric fireplaces can be designed
into plans where other types of fireplaces are not suitable. Electric fireplaces are generally inexpensive to
operate and are highly efficient.
KITCHEN
4"
SECOND-FLOOR
FIREPLACE FLUE
MAIN-FLOOR
FIREPLACE FLUE
CHIMNEY ABOVE
SECOND-FLOOR FIREPLACE
4"-8"
4"
FIREPLACE
FLUE FROM
MAIN FLOOR
SECOND-FLOOR
FIREPLACE
42" BARBECUE
FLUSH HEARTH
FAMILY
FIGURE 1682 Built-in barbecue in fireplace.
MAIN-FLOOR
FIREPLACE
FIGURE 1683 Floor plan drawing of a fireplace at the main
floor, at the second floor, and beyond the second floor.
350
Architectural Drafting and Design
Fireplace
Opening Width
Fireplace
Opening Height
Fireplace
Depth
Flue Size
24" (600 mm)
24" (600 mm)
18" (430 mm)
8" × 12" (200 × 300 mm)
32" (800 mm)
27" (680 mm)
20" (500 mm)
12" × 12" (300 × 300 mm)
36" (900 mm)
29" (730 mm)
20" (500 mm)
12" × 12" (300 × 300 mm)
40" (800 mm)
27" (680 mm)
24" (600 mm)
16" × 16" (400 × 400 mm)
60" (1500 mm)
37" (940 mm)
24" (600 mm)
16" × 20" (400 × 500 mm)
to the structure. The size of each flue and the dimensions of the fireplace structure and the chimney should
be given. The chimney above the second floor can taper
to a smaller size than the fireplace structure, but it needs
to be large enough to accommodate the flues with minimum masonry material surrounding. Installation of
zero-clearance flues for metal fireplaces should be based
on the manufacturer’s specifications. Flues must be
designed to provide proper ventilation and draft for the
fireplace. Draft is a current of air and gases through the
fireplace and chimney. The size of the flue is determined
by the size of the fireplace opening and the chimney
height. The following table gives general guidelines for
standard fireplace openings and chimney heights. Flues
for custom designs and multistory chimney heights
should be confirmed with the masonry contractor,
masonry supply, or fireplace manufacturer.
SOLID FUEL–BURNING APPLIANCES
Floor Protection
Combustible floors must be protected. Floor protection
material shall be noncombustible, with no cracks or
holes, and strong enough not to crack, tear, or puncture
with normal use. Materials commonly used are brick,
stone, tile, or metal.
Wall Protection
Wall protection is critical whenever solid fuel–burning
units are designed into a structure. Direct application of noncombustible materials does not provide
adequate protection. When solid fuel–burning appliances are installed at recommended distances to combustible walls, a 7" air space is necessary between the
wall and floor to the noncombustible material, plus
a bottom opening for air intake and a top opening
for air exhaust to provide positive air change behind
the structure. This helps reduce superheated air next
to combustible material as shown in Figure 16-84.
Solid fuel–burning appliances are items such as airtight
stoves, freestanding fireplaces, fireplace stoves, room
heaters, zero-clearance fireplaces, antique stoves, and
fireplace inserts for existing masonry fireplaces. This
discussion shows the floor plan representation and
minimum distance requirements for typical installations
of some approved appliances.
Appliances that comply with nationally recognized
safety standards are noted on the floor plan with wording such as:
General Rules for Solid Fuel–Burning
Appliances
Verify rules for solid fuel–burning appliances with the
local fire marshal or building code guidelines. The following are some considerations.
DRYWALL
WOOD FRAME
AIR
CIRCULATION
MASONRY OR
NONCOMBUSTIBLE
5'– 0" MIN.
ICC APPROVED WOOD STOVE AND INSTALLATION
REQUIRED. VERIFY ACTUAL INSTALLATION
REQUIREMENTS WITH VENDOR SPECIFICATIONS AND
LOCAL FIRE MARSHAL OR BUILDING CODE GUIDELINES.
CEILING
1" AIR SPACE
HEARTH
FLOOR
FIGURE 1684 Air circulation around wall protection.
Chapter 16: Floor Plan Symbols
351
Noncombustible materials include brick, stone, or tile
over cement asbestos board. Minimum distances to
walls should be verified in regard to vendor specifications and local code requirements.
SCREENED
CLOSABLE VENT
WITHIN 23" OF
STOVE
Combustion Air
Combustion air is generally required as a screened
closable vent installed within 24" of the solid fuel–
burning appliance. Confirm the specific requirements
with manufacturer specifications and building codes.
Provide an appropriate note on the drawing or in the
specifications.
UL APPROVED
WOOD STOVE
WITH BRICK FLUE
AND HEARTH
BRICK ARCH
FIGURE 1686 Masonry alcove for solid fuel–burning stove.
Air Pollution
Most local areas have initiated guidelines that help control air pollution from solid fuel–burning appliances.
The installation of a catalytic converter or other device
is normally required. Check with local regulations and
confirm manufacturer specifications.
Figure 16-85 shows floor plan representations of
common wood-stove installations.
A design option is to construct a masonry alcove
within which a solid fuel unit is installed. The floor
plan layout for a typical masonry alcove is shown in
Figure 16-86.
5" HIGH BRICK VENEER
OVER 1" AIR SPACE
30"
KITCHEN
BATH
FIGURE 1687 Room titles.
FA M I LY
186 X 14Ø
FIGURE 1688 Room title with room sizes noted.
20"
IRC APPROVED
WOOD STOVE W/
SCRN. CLOSABLE
VENT WITHIN 24"
LIVING ROOM
BEDROOM
ROOM TITLES ON FLOOR PLANS
5' X 5' TILE
FLUSH HEARTH
STONE VENEER OVER
1" AIR SPACE AND 15#
FELT W/ METAL TIES
@ 24" O.C. EA. STUD
WOOD STOVE W/
SCRN. CLOSABLE
VENT WITHIN 24"
Rooms are labeled with a name on the floor plan.
Generally, the lettering is larger than that used for other
notes and dimensions. Room titles can be lettered using
letters 3/16" or 1/4" (5 or 7 mm) high, as shown in
Figure 16-87. The interior dimensions of the room can
be lettered under the title using 1/8" (3 mm) text, as
shown in Figure 16-88.
OTHER FLOOR PLAN SYMBOLS
12" RAISED
STONE HEARTH
12" TYP.
FIGURE 1685 Wood stove installation.
Many additional floor plan symbols are available for
placement on the floor plans. Additional electrical
symbols are described and illustrated in Chapter 19,
and plumbing symbols are described and shown in
Chapter 20.
352
Architectural Drafting and Design
Attic and Crawl Space Access
H.B.
FIGURE 1689 Hose bibb symbol.
Hose Bibb Symbol
A hose bibb is an outdoor water faucet to which a
garden hose may be attached. Hose bibbs should be
placed at locations convenient for watering lawns or
gardens and for washing a car. The floor plan symbol for
a hose bibb is shown in Figure 16-89. This symbol can
be shown on a separate plumbing plan, as discussed in
Chapter 20. This often depends on the complexity of the
design and the preferred office or instructional practice.
Concrete Slab Representation
Concrete slabs used for patio walks, garages, or driveways can be noted on the floor plan. A typical example
is 4"-THICK CONCRETE WALK. Concrete slabs used
for the floor of a garage should slope toward the front, or
to a floor drain in cold climates, to allow water to drain.
The amount of slope is 1/8"/ft minimum. A garage slab
is noted in Figure 16-90. Calling for a slight slope on
patios and driveway aprons is also common.
Access is necessary to attics and crawl spaces. An attic
is a floor space consisting of an open area at the top of a
building just below the roof. The attic is often used for
storage. A crawl space is a space between the ground
and the floor of a building in which a person cannot
generally walk upright. An enclosed crawl space is not
accessible from the outside of the building, but crawl
space access can be provided through the foundation
if the design permits. The crawl space access can be
placed in any convenient location such as a closet or
hallway. The crawl access should be 22" × 30" (560 ×
762 mm) minimum if located in the floor, as shown in
Figure 16-91.
Crawl space access can be shown on the foundation
plan when it is constructed through the foundation
wall. When it is in the foundation wall, the minimum
access is 24" × 18" (610 × 460 mm).
The minimum size of the attic access is 22" × 30"
(560 × 762 mm), and it must have 30" (760 mm)
unobstructed headroom above as you enter the attic.
The attic access is commonly placed at the end of a hallway, in a walk-in wardrobe closet, or in a utility room.
Figure 16-92 shows an attic access symbol and related
note. The attic access can include a fold-down ladder
if the attic is to be used for storage. A minimum of 30"
(760 mm) must be provided above the attic access.
22" X 30" CRAWL SPACE ACCESS
S&P
4" CONCRETE SLAB
SLOPE 1/8" MIN/FT.
TO DOOR OR TO
FLOOR DRAIN.
FIGURE 1691 Crawl space access note.
22" X 30" MIN.
ATTIC ACCESS
FIGURE 1690 Garage slab note.
FIGURE 1692 Attic access symbol and related note.
Chapter 16: Floor Plan Symbols
353
A
B
FIGURE 1693 (A) Prefabricated window-well floor plan symbol. (B) Cast-in-place concrete windowwell symbol. See the foundation plan and details for construction dimensions and specifications.
Window Well
A window well is generally a small retaining wall made
of metal, plastic, concrete, masonry, or pressure-treated
wood, and constructed around a basement window to
hold earth away from the windows and allow for grading
or planting around the exterior. Window wells can be
constructed using concrete or masonry and can have a
ladder inside for easy access through the opening above.
Window wells can also be prefabricated metal or plastic,
or precast concrete modules that are combined to form
the desired width and height, and can also be installed
with or without a ladder as needed. Refer to Chapter 9
for window-well ladder code requirements and other
window-well codes. Window wells can be open, or have
a cover or grate on top. The basic function of a window
well is to provide safe egress from the basement through
a window and out through the window well. A window
well for a bedroom window must provide egress using
the same code requirements for any bedroom window.
Any habitable below-grade space must have two ways
to escape in case of fire. Window wells are important
for this purpose. Window wells also provide natural
lighting and ventilation into a basement or other belowgrade space. Window-well drainage is an important
consideration to keep rainwater or snow from entering
the home. Confirm proper drainage requirements or
recommendations with manufacturer specification and
local building codes. A common recommendation is to
have at least 12" (300 mm) of gravel below the base of
the window well and have the grade above drain away
from the building. Ideally, a window well should have a
drainpipe that drains water to the footing drain or away
from the foundation and to a storm sewer. Windowwell specifications can be noted on the floor plan using
specific or general notes, in specifications, or on the
foundation plan, and construction details should be
provided if necessary. Figure 16-93 shows the floor plan
representation of a window well.
Floor Drain Symbol
A floor drain floor plan symbol for a shower is shown
in Figure 16-94. Floor drains should be used in any
location where water can accumulate on the floor, such
as the laundry room, bathroom, or garage. The easiest
application for a floor drain is in a concrete slab floor.
Drains can be designed in any type of floor construction,
although this is more difficult in wood-frame construction. Figure 16-95 shows a floor drain in a utility room.
Cross-Section Symbols
The location on the floor plan where a cross section is
taken is identified with symbols known as cutting-plane
lines. A cross section, also called a section, is a type of
42" FIBERGLASS
SHOWER OVER
1/2" W.P. GYP. BD.
FIGURE 1694 Shower symbol showing floor drain.
354
Architectural Drafting and Design
UTILITY
SLOPE FLOOR
TO DRAIN
68
FIGURE 1695 Floor drain symbol. This symbol can be square
if the desired drain fixture is square.
CUTTING PLANE THROUGH
CENTER OF CIRCLE
DRAW ARROW TANGENT
TO CIRCLE AT
45°, FILL IN DARK
A
5
28
A
DRY
A
5
SHELF
WASH
4' X 3' A S
W/4 X 6 HDR
L/T
BASIC METHOD
CUTTING PLANE
AND LABEL ONLY
APPROXIMATE 1/2"Ø
CIRCLE
drawing showing an object as if it has been cut through
to show interior construction methods and materials.
Cutting-plane lines show the location of a cut made for
the purpose of creating a sectional view at the specified
location. Cutting-plane lines can be placed on floor
plans, foundation plans, or any place where a section
needs to be drawn to show the internal construction.
These symbols are described and shown in detail in
Chapter 36 through Chapter 40.
Figure 16-96 shows options for the cutting-plane
line symbol. The method used depends on your school
or office practice and the drawing complexity.
CONCLUSION
Floor plans are a key element in a complete set of architectural drawings. Clients are interested in floor plans
so they can see how their future home or business is
laid out. As you have seen in this chapter, a large variety
A
5
LETTER DENOTES
SECTION IDENTIFICATION
A
5
NUMBER DENOTES
THE PAGE THE SECTION
IS FOUND ON
SYMBOL DRAWN WITH
FEATURES LETTERED
HORIZONTALLY
OPTION 2
SYMBOL DRAWN WITH
FEATURES LETTERED
TO READ FROM RIGHT
OPTION 1
SHEET WITH CUTTING
PLANE THAT LOCATES
SECTION
SECTION
A
12
SHEET WHERE DRAWING
OF SECTION IS SHOWN
OPTION 3
FIGURE 1696 Options for the cutting-plane line symbol.
of symbols and drawing techniques go into preparing
a floor plan. The challenge to the architectural drafter
is to be sure to include all the necessary symbols and
notes needed for construction while making the plan
easy to read.
CADD APPLICATIONS
CADD Floor Plan Symbols
INTRODUCTION
Floor plans often contain many symbols beyond the
standard architectural building features such as door,
window, stair, and wall symbols. Symbols drawn on
floor plans can also represent furniture, plumbing
fixtures, plants, and documentation symbols such as
detail bubbles, keynotes, and section marks. Drawing
symbols by hand requires a template in the shape of
the symbol to be drawn, time to draw the symbol,
and time and effort to change hand-drawn symbols
Chapter 16: Floor Plan Symbols
355
CADD APPLICATIONS
in the event of a design change. With CADD, standard
symbols are available in an electronic format that can
be easily and quickly added to and modified in a floor
plan. Various CADD software packages are available
that provide complete symbol library templates. These
CADD programs usually include symbols for windows,
doors, structural elements, electrical symbols, furniture
shapes, appliance and plumbing fixture symbols, and
site plan symbols as shown in Figure 16-97. In addition
to software symbol libraries, the Internet can be used
to locate CADD symbol libraries for the specific CADD
programs.
All CADD programs include a function for adding
symbols to a drawing. Methods range from specific insert
and add commands to point and click and drag and drop.
Once a symbol is added to the CADD drawing, different
tools or commands can be used to modify the symbol.
Tools such as moving, copying, rotating, and erasing
can all be used on CADD symbols to quickly modify the
floor plans. Using CADD in this manner saves time and
cost when compared to the manual drafting method of
adding symbols. Figure 16-98 displays some examples
of a CADD floor plan with symbols added.
Manufacturer Symbol Libraries
Manufacturers of many architectural products such
as doors, windows, plumbing fixtures, and appliances
have CADD symbol libraries available for use in CADD
floor plan design and drafting. Many of these symbols
include the graphical representation of the manufactured
item, and additional data assigned to the symbol that
can be extracted and used as a bill of materials or
(a)
(b)
(c)
(d)
FIGURE 1697 Many different CADD programs include libraries of symbols that can be added to floor plans and CADD models.
356
Architectural Drafting and Design
CADD APPLICATIONS
FIGURE 1698 This floor plan includes a number of symbols that represent furniture, doors, and windows. Courtesy Ron Palma,
3D-DZYN.
compiled into schedules. Most of these product libraries
allow you to create drawings quickly in floor plans,
elevations, perspective views, and construction details. As
technology improves, CADD drawings are beginning to
evolve from 2D representations of real-world objects to
3D models of actual manufactured items. Manufacturers
are beginning to follow this trend and include 2D and 3D
symbol libraries for customers to use.
Manufacturers such as Andersen Corporation,
Woodwork Institute, USG Design Studio, Jeld-Wen,
Kohler, and Herman Miller are examples of companies
and manufacturers who have created symbol libraries
for CADD drawings. Figure 16-99 displays a couple of
manufacturer Web pages with their CADD content.
Creating Your Own Symbol Libraries
In addition to symbol libraries included with software
programs, libraries of symbols on the Internet, and
manufacturer-provided symbols, most CADD software
programs allow you to create your own symbols. This is
another benefit to CADD. A new symbol can be created,
saved in a CADD library of symbols, and used later in
other projects. Most architectural firms maintain libraries
of custom CADD symbols that comply with company
standards. In some cases, a manufacturer symbol is too
specific for a design so a more generic symbol is desired.
In this situation, the manufacturer symbol can be
modified as needed and saved in the company symbol
library to quickly create a new symbol for use on multiple
drawings.
Symbols are an important part of CADD drawings,
whether you use symbols from the software, download
symbols from a Web site, or create your own symbols.
The reuse and ease of placing and modifying symbols in
a CADD drawing is one of the benefits of CADD. ■
Chapter 16: Floor Plan Symbols
357
CADD APPLICATIONS
(a)
(b)
FIGURE 1699 Many product manufacturers provide CADD symbols and libraries of their products for designers and drafters to use
in CADD drawings.
ADDITIONAL RESOURCES
See CD for more information
The following Web sites can be used as a resource to
help you research available products and floor plan
design options.
These Web site links are also provided on the Student
CD where you can select a link and go automatically to
the specified Web site.
Address
www.kitchenaid.com
www.homedepot.com
Company, Product,
or Service
Appliances
Appliances, cabinets,
plumbing fixtures
www.lowes.com
www.abracadata.com
www.autodesk.com
www.eaglepoint.com
www.graphisoft.com
www.generalshale.com
Appliances, cabinets,
plumbing fixtures
Architectural CADD
software
Architectural CADD
software
Architectural CADD
software
Architectural CADD
software
Brick masonry products
358
www.builtinvacuum.com
www.aristokraft.com
www.homecrestcab.com
www.kraftmaid.com
www.beamvac.com
www.nutone.com
www.solatube.com
www.optiflame.com
www.heatilator.com
www.heatnglo.com
www.whirlpool.com
www.nfrc.org
www.ssina.com
Architectural Drafting and Design
Built-in vacuum systems
Cabinets
Cabinets
Cabinets
Central cleaning systems
Communication systems
Daylighting systems and
Tubular Daylighting Devices
Electric fireplaces
Fireplaces
Fireplaces and products
Home appliances
National Fenestration Rating
Council
The Stainless Steel
Information Center
Storage systems
www.caddepot.com
Use in assembling symbol
libraries
www.catalog.com
Use in assembling symbol
libraries
www.waterfurnace.com
Water Furnace International,
Inc.
www.jacuzzi.com
Whirlpool bath fixtures
www.andersenwindows.com
Window and door fixtures
www.crestlineonline.com
Window and door fixtures
www.marvin.com
Window and door fixtures
www.pella.com
Window and door fixtures
www.wellcraftwells.com
Window wells
www.whiteblockcompany.com Window wells
www.schultestorage.com
See CD
for more
information
Floor Plan Symbols Test
QUESTIONS
DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet
of notebook paper, or complete the electronic chapter test on
the Student CD.
1. Letter your name, Chapter 16 Test, and the date at the top of
the sheet.
2. Letter the question number and provide the answer. You do
not need to write the question. Answers can be prepared on
a word processor if approved by your course guidelines.
Question 16–1 Exterior walls for a wood-frame
residence are usually drawn how thick?
Question 16–6 Sketch the following floor plan symbols:
a. Pocket door
b. Bifold closet door
c. Casement window
d. Sliding window
e. Skylight
f. Ceiling beam
g. Single-run stairs, up
h. Hose bibb
Question 16–2 Interior walls are commonly drawn how
thick?
Question 16–7 Letter the note that would properly
identify a wall 48" high.
Question 16–3 How does the floor plan symbol for an
interior door differ from the symbol for an exterior
door?
Question 16–8 What is the required minimum height of
guardrails?
Question 16–4 What are the recommended spaces for
the following?
a. Wardrobe closet depth
b. Water closet compartment
c. Stair width
d. Fireplace hearth depth
Question 16–5 Describe an advantage of using
schedules for windows and doors.
Question 16–9 Provide the appropriate note used to
identify a guardrail at a balcony overlooking the living
room.
Question 16–10 What type of door would you
recommend when space for a door swing is not
available?
Question 16–11 Name the window that you would
recommend when a 100% openable unit is required.
Question 16–12 What does the note 6040 next to a
window on the floor plan mean?
Chapter 16: Floor Plan Symbols
Question 16–13 What is the minimum crawl space or
attic access required?
Question 16–14 What is the abbreviation for garbage
disposal?
Question 16–15 When should the clothes washer and
dryer be shown with dashed lines on the floor plan?
Question 16–16 Identify in short, complete statements
four factors to consider in stair planning.
Question 16–17 Show the note used to identify the
steps at a two-step sunken living room.
359
2. Make exterior walls 6" thick and interior walls 4" thick if
using manual drafting. Draw exact thickness if using CADD.
3. Use the line and architectural lettering methods described in
this textbook. Letter only the notes that are part of the drawing. Estimate dimensions when not given and increase sizes
to help fill paper when appropriate. Do not draw dimensions
or pictorial illustrations.
Problem 16–1 Redraw Figure 16-5, Figure 16-6, Figure
16-8, and Figure 16-9.
Problem 16–2 Redraw Figure 16-10.
Question 16–18 What is the amount of slope for a
concrete garage floor and why should it have a slope?
Problem 16–3 Redraw Figure 16-13 through Figure
16-18.
Question 16–19 If you are using CADD to draw a
floor plan, what dimension will you use to draw
the interior walls to their exact width if 2 × 4 studs
are used with 1/2" gypsum on each side? Show the
calculations.
Problem 16–4 Redraw Figure 16-19 through Figure
16-22.
Question 16–20 If you are using CADD to draw a
floor plan, what dimension will you use to draw
the exterior walls to their exact width if 2 × 4 studs
are used with 1/2" gypsum on the inside and 1/2"
sheathing and siding on the outside? Show the
calculations.
Problem 16–7 Redraw Figure 16-32.
Question 16–21 Define header.
Problem 16–10 Redraw Figure 16-51.
Question 16–22 How are upper cabinets normally
drawn on the floor plan?
Problem 16–11 Redraw Figure 16-52.
Question 16–23 List at least four factors that can
influence window sizes.
Problem 16–5 Redraw Figure 16-23.
Problem 16–6 Redraw Figure 16-24 through Figure
16-28, and Figure 16-31.
Problem 16–8 Redraw Figure 16-38. Draw the partial
floor plan and door/window key symbols. Do not
draw the door/window schedules.
Problem 16–9 Redraw Figure 16-40.
Problem 16–12 Redraw Figure 16-57, Figure 16-59, and
Figure 16-63.
Question 16–24 Define soft metric conversion.
Problem 16–13 Redraw Figure 16-67 through Figure
16-71.
Question 16–25 Define hard metric conversion.
Problem 16–14 Redraw Figure 16-72.
Question 16–26 How is it possible to have a satisfactory
stair design that might be less than perfect?
Problem 16–15 Redraw Figure 16-74 and Figure 16-75.
Question 16–27 Why is stair design sometimes
complex?
Problem 16–16 Redraw Figure 16-76 through Figure
16-82.
Problem 16–17 Redraw Figure 16-83.
Question 16–28 Define flue.
Problem 16–18 Redraw Figure 16-85 and Figure 16-86.
Question 16–29 Why does the fireplace structure for
multilevel construction with more than one fireplace
need to be wider than a fireplace for a single-story
building?
Problem 16–19 Redraw Figure 16-90.
Question 16–30 Give the flue size for a standard
fireplace opening 36" W × 29" H × 20" D.
Problem 16–22 Redraw Figure 16-94 and Figure 16-95.
PROBLEMS
DIRECTIONS
1. Draw the following problems manually or with CADD,
depending on your course guidelines. Use a 1/4" = 1'–0"
scale. Draw on 8 1/2 × 11" vellum for manual drafting and
follow CADD guidelines given in Chapter 7.
Problem 16–20 Redraw Figure 16-91 and Figure 16-92.
Problem 16–21 Redraw Figure 16-93.
Problem 16–23 Redraw Figure 16-96.
Problem 16–24 Create your own CADD symbols to
match the symbol examples provided throughout this
chapter.
CHAPTER 17
Floor Plan Dimensions
and Notes
I
N
T
R
O
D
U
C
T
I
O
N
Dimensions provide the measurements used for construction.
Dimensions are found on all types of architectural drawings and
are presented using lines, numerical values, and symbols, or
notes and specifications. Drawings must include all the dimensions needed for construction, so workers do not have to guess
about the size and location of features in the building. It can be a
challenge to decide what dimensions are needed, to determine
the best dimension placement, and to locate dimensions in a
manner that keeps the drawings uncluttered and easy to read.
This chapter provides you with the dimensioning systems and
techniques used to meet these objectives.
ALIGNED DIMENSIONS
The dimensioning system most commonly used in
architectural drafting is known as aligned dimensioning. With this system, dimensions are placed
in line with the dimension lines and read from the
bottom or right side of the sheet. Dimension numerals are typically centered on and placed above the
solid dimension lines. Figure 17-1 shows a floor
plan that has been dimensioned using the aligned
dimensioning system. A dimension line is a line
showing the length of the dimension, terminating at
the related extension lines. Extension lines are lines
showing the extent of the dimension and start with a
small space from the feature being dimensioned and
extend past the last dimension line.
FLOOR PLAN DIMENSIONS
You should place dimensions so the drawing does
not appear crowded. However, this is often difficult
because of the great number of dimensions that must
be placed on an architectural drawing. When placing
dimensions, space dimension lines a minimum of
3/8" (10 mm) from the object and from other dimension lines. If there is room, 1/2" (13 mm) is preferred.
Architectural drafters often use 1" (26 mm) or more if
space is available. Other drafters place the first dimension line 1" (26 mm) away from the plan and space
additional dimensions equally 1/2" (13 mm) or 3/4"
360
(20 mm) apart. The minimum recommended spacing of dimensions is shown in Figure 17-2. Confirm
the recommended dimension line spacing with your
office or instructional standards. Regardless of the
distance chosen, be consistent so dimension lines
are evenly spaced and uniform throughout the drawing. Figure 17-2 also shows the recommended 1/16"
(1.5 mm) space between the start of the extension
line and the floor plan or feature being dimensioned.
Notice the extension lines extending 1/8" (3 mm)
past the last dimension line.
Extension and dimension lines are drawn thin
and dark so they do not detract from the overall
appearance and balance of the drawing. Dimension
lines terminate at extension lines with dots, arrowheads, or slash marks that are each drawn in the
same direction (see Figure 17-3). The U.S. National
CAD Standard recommends slash marks or filled
arrowheads. The type of dimension line terminators
should be the same throughout the drawing; however, slash marks are common on dimension line
terminators and filled arrowheads are used on leaders for notes as described later in this chapter.
Dimension numerals are drawn 1/8" (3 mm) high
and are centered above the dimension line with a
1/16" (1.5 mm) space between the dimension line
and the value. For all lengths over 12", the dimension
units used are feet and inches. Inches and fractions
are used for units less than 12". Foot units are followed by the symbol ('), and inch units are shown
by the symbol ("). For example, 14'–6" means 14 feet
and 6 inches.
Metric dimensions are given in millimeters (mm),
as discussed later in this chapter; however, metric sizes
vary, depending on hard or soft conversion. Soft conversion is the preferred method, which is explained in
Chapter 16 and again later in this chapter.
PLACING EXTERIOR DIMENSIONS
The overall dimensions on frame construction are given
to the outside of the stud frame of the exterior walls.
The reason for locating dimensions on the outside of
Chapter 17: Floor Plan Dimensions and Notes
361
FIGURE 171 Aligned dimensions on a floor plan. Courtesy Alan Mascord Design Associates, Inc.
the stud frame is that the frame is established first, and
windows, doors, and partitions are usually put in place
before sheathing and other wall-covering material is
applied. Another construction option is for the exterior
dimensions to be to the outside face of the exterior
sheathing. This depends on the preferred construction method. Figure 17-4A shows an example of the
construction used where the exterior dimension is to
the outside face of studs. Compare this with the outside
face of the sheathing in Figure 17-4B. Your floor plan
dimensioning practice is the same either way. The contractor determines the actual construction method. Stud
frame is the vertical construction members of a woodor steel-frame wall, where the individual members,
362
Architectural Drafting and Design
16'-0"
10'-0"
6'-0"
SPACE
DEPENDS
UPON
AVAILABLE
ROOM 3/8"
TO 1"
EXTERIOR DIMENSION
APPROXIMATELY 1/8"
FACE OF
STUDS
DIMENSION
LINES
EQUAL SPACE
3/8" MINIMUM
5'-0"
5'-0"
INTERIOR
EXTENSION
LINES, TO
CENTER OF
FEATURE
STUDS
1/16"
EXTERIOR EXTENSION
LINE, ASSUMED TO
OUTSIDE FACE OF STUDS
OR SHEATHING,
SEE FIGURE 17-4.
SHEATHING
SIDING
FOUNDATION WALL
FIGURE 172 Recommended spacing of dimension lines, and
dimensioning terminology.
FACE OF
SHEATHING
A
called studs, are usually placed between bottom and top
plates that are spaced every 16" or 24" apart.
The first line of dimensions on the plan is the shortest
distance from the exterior wall to the center of the windows, doors, and to the interior partitions. The second
line of dimensions generally gives the distance from the
outside walls to the interior partitions. The third line
of dimensions is usually the overall distance between
two exterior walls (see Figure 17-5). This method of
applying all dimensions eliminates the need for workers
to add dimensions at the job site and reduces the possibility of error.
The three dimensioning methods commonly used by
architectural offices to dimension floor plans are center
line, face-of-stud, and face-of-finish-material.
EXTERIOR DIMENSION
STUDS
SHEATHING
SIDING
FOUNDATION WALL
B
FIGURE 174 (A) An example of the construction used
when exterior dimensions are to the outside face of studs.
(B) Construction used when exterior dimensions are to the
outside face of sheathing.
DIMENSION LINE
10'-0"
EXTENSION
LINE
5'-0"
5'-0"
1/8
45°
CENTER-LINE
EXTENSION
LINE
FREEHAND SLASH
ALL IN THE SAME
DIRECTION
10'-0"
5'-0"
1/8"
A THICK SLASH
IS COMMON ON
MANY MANUAL
AND CADD
DRAWINGS
SOME COMPANIES
USE A DOT TO
END DIMENSION
LINES
TO 3/16"
5'-0"
1/16
FREEHAND
ARROWHEAD
CADD ARROWHEADS MAY BE FILLED
OR UNFILLED
FIGURE 173 Methods for terminating dimension lines. The slash mark and filled arrowhead are options recommended by the U.S.
National CAD Standard.
Chapter 17: Floor Plan Dimensions and Notes
FACE OF STUD
363
FACE OF STUD
FACE OF STUD
9'-4 1/4"
3'-10 1/4"
DOOR
CENTER LINE
WINDOW
CENTER LINE
Using the Center-Line Dimensioning Method
The center-line dimensioning method places dimensions from the outside face of exterior stud walls to the
center of interior partitions, and to the center of doors
and windows. An overall dimension is placed as the
last dimension. This traditional dimensioning method
is shown in Figure 17-5.
Using the Face-of-Stud
Dimensioning Method
The traditional method of floor plan dimensioning has
been from the outside face of studs to the center of partition walls, windows, and doors. More recently, architectural offices have been dimensioning to face of stud for
locating interior partitions. This technique establishes
where the structure of the wall is laid out. Interior wall
surfaces and finishes are not typically dimensioned on
floor plans, but are shown in the details. Using CADD,
building component sizes are drawn accurately, for
example, a 2 × 4 stud actually measures 1 1/2" × 3 1/2".
Interior dimensions are to the face of the stud not the
center of the stud, because dimensioning to the center
splits the stud in half, giving fractional dimensions.
Partition center-line and fractional dimensions require
field calculations that are difficult to perform and are
not generally followed by builders.
Typically, when dimensioning to a face of the stud,
the selected side is personal preference or an office standard. Generally, you start on one side of the building at
the corner, and then pick an interior partition stud face.
Then all of the dimensions in the string are consistently
established to the same side throughout the plan. This
technique can vary depending on the features being
dimensioned. For example, dimensions can be between
inside stud faces where it is important to dimension the
10'-7 3/4"
5'-4 3/4"
DOOR
CENTER LINE
WINDOW
CENTER LINE
FACE OF STUD
INTERIOR PARTITION
CENTER LINE
FIGURE 175 Placing exterior dimensions from the outside
face of exterior studs to the center of interior partitions, and
the center of doors and windows.
FACE OF STUD
FIGURE 176 Placing exterior dimensions from the outside
face of exterior studs to the face of studs at interior partitions,
and the centers of doors and windows.
open width of an area such as the partitions between a
bathtub, shower, or hallway. Some companies dimension the width of the stud, such as 3 1/2", but this is
unnecessary information that can be covered in a general note that indicates stud sizes, or in sections and
details. The face-of-stud dimensioning method places
dimensions from the exterior face of studs, to the interior face of studs, and to the centers of doors and windows as shown in Figure 17-6.
Using the Face-of-Finish-Material
Dimensioning Method
The face-of-finish-material dimensioning method is
typically not used in new construction. This method
can be used in remodeling projects where interior
dimensions are commonly related to the existing face
of finish material. Dimensions to doors and windows
are still given to their center lines (see Figure 17-7).
FACE OF STUD
9'-3 3/4"
3'-9 3/4"
FACE OF STUD
10'-8 1/4"
5'-5 1/4"
DOOR
CENTER LINE
WINDOW
CENTER LINE
FACE-OF-FINISH
MATERIAL
FIGURE 177 Placing exterior dimensions from the outside
face of exterior studs to the face of finish material at interior
partitions, and the centers of doors and windows. This method
can be used when dimensioning remodeling projects where
measurements are established from existing finish material.
364
Architectural Drafting and Design
PLACING INTERIOR DIMENSIONS
Interior dimensions locate all interior partitions and
features in relation to the face of exterior wall studs.
Any of the dimensioning methods (center line, face-ofstud, or face-of-finish material) can be used for placing
interior dimensions. In an effort to simplify construction and minimize field calculations, the face-of-stud
method is most commonly used for new construction.
Figure 17-8 shows some common interior dimensions.
Notice how the dimensions relate to the face of exterior
wall studs. The interior partition dimensions are given
to the face of studs and can be consistently given to the
same side throughout the plan. Another option is to
dimension the face of studs between an opening, such
as the opening framed for a bathtub, or the width of
a water closet compartment as shown in Figure 17-8.
When dimensioning interior features, be sure to provide
workers with enough dimensions to build the house.
The contractor should not have to guess where a wall
or feature is located, nor should workers have to use a
scale to try to locate items on a plan.
Stub walls are walls that do not go all the way across
a room, and are dimensioned by giving their location
INDICATES TO
NEXT FEATURE
to a stud face and their length. Windows and doors are
dimensioned to their centers, unless the location is
assumed. Look at Figure 17-8 again for examples of
dimensioning interior features.
STANDARD FEATURE DIMENSIONS
Some interior features that are considered to be standard
sizes may not require dimensions, even though providing dimensions is generally a good idea to help reduce
construction errors. Figure 17-9 shows a situation in
which the drafter elected to omit the depth of the pantry
because it is directly next to a refrigerator, which has an
assumed depth of 30" (760 mm), and near a base cabinet that is typically 24" (600 mm) deep. The refrigerator
width should be given because there are many different
widths available. The base cabinet is not dimensioned,
because such cabinets are typically 24" (600 mm) deep.
When there is any doubt, it is better to apply a dimension. The refrigerator and other appliances can be drawn
with dashed lines or marked with the abbreviation NIC
(not in contract) if the unit is not supplied according
to the contract for the home’s construction. Follow the
practice of the office where you work.
Other situations in which dimensions can be assumed
are when a door is centered between two walls as at
the end of a hallway, and when a door enters a room
and the minimum distance from the wall to the door
is assumed. See the examples in Figure 17-10. Some
dimensions can be provided in the form of a note for
standard features, as seen in Figure 17-11. The walls
around a shower need not be dimensioned when a note,
36" (900 mm) square shower, defines the inside dimensions. The shower must be located and actual product
dimensions verified during construction.
One of the best ways to learn how experienced drafters lay out dimensions is to study and evaluate existing
plans. Metric dimensions can vary depending on hard
or soft conversion, as discussed in Chapter 16 and later
in this chapter.
BASE
CABINET
PANTRY
FIGURE 178 Placing interior dimensions. Dimensions are placed
from the face of exterior studs to the face of studs at interior partitions, and to the centers of doors and windows. Dimensions can
be placed to establish an opening between the face of interior
studs, such as for the width of a bathtub, water closet, or hallway.
REF
36 X 30
FIGURE 179 The dimension for the location of a feature such
as the depth of a pantry can be assumed when it is next to a
base cabinet with a known 
Download