Automotive Engineering Centre, UET Lahore Vehicle Air Conditioning Laboratory Name: _________________________ Reg. No.: ________________ Date: ______________ EXPERIMENT NO. 1: DEMONSTRATION OF THE VAPOR COMPRESSION REFRIGERATION CYCLE AND PRODUCTION OF THE CYCLE DIAGRAM UNDER VARIOUS CONDITIONS. APPARATUS: As per figure attached PROCEDURE: Switch on the Refrigeration Laboratory Unit apparatus after taking care of all the necessary precautions. Allow running of the apparatus for a while so that the readings shown become stable. Change the evaporator input by the knob provided for each set of readings. To keep condenser pressure constant, change water flow rate accordingly. Insert the values in the table of observations. TABLE/OBSERVATIONS: Sr No. Evaporator Condenser Pressure* Pressure* (kNm-2) (kNm-2) Pevp 1 2 3 4 *Absolute Pressure Pcon Water flowrate g/s Compressor Condenser Suction delivery Temp. (oC) Temp. (oC) mw T1 T2 Exp. Valve Inlet Temp. (oC) T3 Evaporator Inlet Temp. (oC) T4 SPECIMEN CALCULATION: (For first set of readings) Draw the state points on p-h diagram as follows: 1. 2. 3. 4. Is located by the intersection of Pevp= and T1= Is located by the intersection of Pcon= and T2= Is located by the intersection of Pcon= and T3= Is located by dropping a vertical line (assumed adiabatic) from point 3 to the intersection with Pcon line. Automotive Engineering Centre, UET Lahore Vehicle Air Conditioning Laboratory COMMENTS: