AVEVA™ Dynamic Simulation
Release Notes
Version 2022
April 2022
aveva.com
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
No part of this documentation shall be reproduced, stored in a retrieval system, or transmitted by any means,
electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of AVEVA.
No liability is assumed with respect to the use of the information contained herein.
Although precaution has been taken in the preparation of this documentation, AVEVA assumes no responsibility
for errors or omissions. The information in this documentation is subject to change without notice and does not
represent a commitment on the part of AVEVA. The software described in this documentation is furnished under
a license agreement. This software may be used or copied only in accordance with the terms of such license
agreement.
ArchestrA, Avantis, Citect, DYNSIM, eDNA, EYESIM, InBatch, InduSoft, InStep, IntelaTrac, InTouch, OASyS,
PIPEPHASE, PRiSM, PRO/II, PROVISION, ROMeo, SIM4ME, SimCentral, SimSci, Skelta, SmartGlance, Spiral
Software, WindowMaker, WindowViewer, and Wonderware are trademarks of AVEVA and/or its subsidiaries. An
extensive listing of AVEVA trademarks can be found at: https://sw.aveva.com/legal. All other brands may be
trademarks of their respective owners.
Publication date: Friday, April 22, 2022
Contact Information
AVEVA Group plc
High Cross
Madingley Road
Cambridge
CB3 0HB. UK
https://sw.aveva.com/
For information on how to contact sales and customer training, see https://sw.aveva.com/contact.
For information on how to contact technical support, see https://sw.aveva.com/support.
To access the AVEVA Knowledge and Support center, visit https://softwaresupport.aveva.com.
Contents
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Kit Location Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Hardware and Software Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
AVEVA Dynamic Simulation 2022 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pre-Install Checklist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
AVEVA Dynamic Simulation Secure Deployment Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Port Usage in AVEVA Dynamic Simulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Setting CORBA IP Port Numbers in AVEVA Dynamic Simulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Software Co-Existence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
PRO/II to DYNSIM (P2DS) Translator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control Emulation and I/A Series Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Summary of Features and Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Infrastructure Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Upgrade to 64-bit architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support for MS Office and Excel 64-bit version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GUI Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GUI Modernization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction of Ribbon Bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Access Toolbar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simulation Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous UI changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cryogenic Exchanger Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Header Enhancement – Advanced Header. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Invariant Co-ordinates for Compressor Performance Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stream with Embedded Conductance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermodynamics Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Open Form VLLE and Super linear local flash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simplified Flash Option Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AVEVA Learning Monitor 2022. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
15
15
15
15
15
16
16
16
17
17
17
18
18
18
19
19
19
20
20
Page 3
AVEVA™ Dynamic Simulation Release Notes
Contents
Known Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Message pop up while opening BulkConfigurator file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UOM issues upon migration with ElecSolve models.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Float Point Errors during load or runtime. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Windows Look and Feel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pipe fitting calculations with exit effect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flash statistics window response. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
21
21
22
22
22
Summary of Defects Resolved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Summary of Defects and Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Where to Find AVEVA Dynamic Simulation Software Documentation. . . . . . . . . . . . . 30
Documentation Included with this Package in Installation Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Printed Documentation Included with this Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Online Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 4
Introduction
AVEVATM Dynamic Simulation 2022 introduces the following set of new features and enhancements.
Note: AVEVA Dynamic Simulation 2022 is supported only on 64-bit operating systems and not on 32-bit operating
systems.
1. Infrastructure Enhancements
• Upgrade GUI and Server components to 64-bit architecture
• Support for MS Office 365 Excel 64-bit version
2. GUI Features
• GUI Modernization
• Support for Dark and Light themes
• New ribbon bar menu options with new icons
3. Model Enhancements
• Cryogenic Exchanger Robustness Improvements
• Header – Auto Solution Algorithm Selection & Robustness Improvements
• Compressor Dimensionless Scaling Enhancements – Improved Accuracy
• Stream Conductance
4. Thermodynamics Enhancements
• Open Form VLLE and Super linear local flash
• Simplified Flash Option Configuration
5. Miscellaneous Enhancements
• New Learning Monitor Tool (Customization Team)
• Available upon request. Not available with regular install
• New Web Server for communication
• Enhanced security authentication through AUTH0 server for LaaS licensing
6. Technology Upgrade
• Windows Server 2019 OS support
• Windows 11 OS Support
• JAVA Upgrade – JDK 15
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 5
AVEVA™ Dynamic Simulation Release Notes
Introduction
• Visual Studio 2019
• .NET 4.7.2
7. AVEVA Dynamic Simulation Secure Deployment Guidelines
A new section has been added in the Release Notes as well as in the Getting Started Guide.
For more details, see Summary of Features and Enhancements in this document. For known issues/things to
keep in mind, refer to Known Issues.
AVEVA Dynamic Simulation 2022 also addresses several key defects found in prior versions. For more details, see
Summary of Defects Resolved in AVEVA Dynamic Simulation 2022.
Installation Kit Location Notice
Install kits are available on DVD media as well as on the Electronic Software Distribution (ESD) site at https://
softwaresupport.aveva.com/. To request a DVD, contact simsci.productrequest@aveva.com. You will need
an authorization code to access the Software ESD area specific for downloading AVEVA Dynamic Simulation
2022. Please request your new authorization code through the ESD site.
Hardware and Software Requirements
The following are the minimum system requirements:
Configuration
Server Hardware
Processor:
Intel® Pentium® Processor 2.8 GHz or higher
Number of cores:
4
Random Access Memory (RAM):
• Minimum requirement: 8 GB
• Recommended: 32 GB (for OTS projects)
Available Space on Hard Disk:
• Minimum requirement: 200 GB
• Recommended: 500 GB SSD
Monitor size and resolution:
24" monitor with 1920 x 1080 resolution.
Note: It is recommended to use the default scaling and layout of the operating
systems.
Operating System
Note: AVEVA Dynamic Simulation 2022 is supported only on 64-bit operating systems
and not on 32-bit operating systems.
• Windows 10 Enterprise (20H2)
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 6
AVEVA™ Dynamic Simulation Release Notes
Introduction
• Windows 10 Professional
• Windows 10 Enterprise, Japanese
• Windows 11 Enterprise (21H2)
• Windows Server 2016 Standard
• Windows Server 2019 Standard
Note: You are recommended to install Microsoft Excel with Office 365 support (64-bit) while installing AVEVA
Dynamic Simulation or utilizing AVEVA Dynamic Simulation Bulk Configurator for tieback configuration. Open
Microsoft Excel sheet at least once to register the Microsoft Excel product key. Windows Classic desktop theme is
preferred over any other theme.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 7
AVEVA Dynamic Simulation 2022
Installation
AVEVA Dynamic Simulation Prerequisites (Windows Installer 4.5 and .NET 4.7.2) and third-party installations like
SQL Express 2014, are part of the main installer. A separate pre-requisites installer is not needed.
Custom OTS Engines install AvevaOtsEngines2022 is a separate installer.
AVEVA Dynamic Simulation 2022 includes Thermo Data Manager (TDM) version 5.0 to allow management of
Pure Component and Binary Interaction Data. The TDM application is supplied as part of the AVEVA Dynamic
Simulation Software installation and is accessed only through the AVEVA Dynamic Simulation Software user
interface.
Schema evolution of simulations developed with AVEVA Dynamic Simulation Software 5.3.x, 6.0, 6.1, 2021 to
AVEVA Dynamic Simulation 2022 is supported. Migration of AVEVA Dynamic Simulation Software simulations
created with earlier versions (prior to 5.3.x) directly to AVEVA Dynamic Simulation 2022 is not supported. It is
recommended to upgrade the older versions to 5.3.x versions before migrating to the target version directly.
Models from AVEVA Dynamic Simulation 2022 cannot migrate to earlier released versions of AVEVA Dynamic
Simulation Software.
SQL server 2014 is an optional install option which is required only for migration of older .s4m to .js4m
migration. JRE (Java Runtime), which used to be installed as a separate component is now prepackaged with the
regular AVEVA Dynamic Simulation install.
Installation Options
The security option used is typically selected during the install procedure. If you want to switch to a different
security method after installation, refer to the Switching Security Types section in the Getting Started Guide.
Note: USB security keys are no longer supported. For any assistance on USB support, please contact AVEVA
technical support.
You may choose the destination folder for installation. The software will be installed in multiple folders located
within the specified folder.
After choosing the installation type, choose a security type from the following:
FNP 11.16 STD
Software-based keys that require installation of FlexNet 11.16 license server and
manager. Once you have selected the FlexNet security option, you must specify the
computer on which the FlexNet security server will reside. The computer name must
be preceded with the @ sign (e.g., @DYNSIM01securityhost). This will add the
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 8
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
IPASSI_LICENSE_FILE environment variable to your system, which in the case of this
example; will be set to FlexNet Security Server.
TOKEN 11.16 TKN
AVEVA LOCAL
These security options allow the use of multiple AVEVA products from a common
license pool of tokens. The terms and availability of this Token license option must first
be established through a separate AVEVA contract. Token licensing requires special
arrangements for regional technical and licensing support.
In addition to the FNP online licensing, where the AVEVA application communicates
with the license server in a real-time manner, AVEVA also offers SECALS licensing.
SECALS security type allows the AVEVA application to obtain the license from an
AVEVA license server that exist either on local machine or on the network.
To use this security type, select SECALS option from the available list of security types
and provide the AVEVA license sever name while installing AVEVA Dynamic
Simulation.
AVEVA LaaS
This security type allows the AVEVA application to obtain the license through the web
from a license server hosted on the AVEVA premise (https://
license.connect.aveva.com).
NOTE: The web distribution package does not include a FlexNet Server security installation. It must be
downloaded separately if you are setting up FlexNet security for the first time.
NOTE: To change the type of security system, use Start->Settings->Control Panel->Add/Remove Program->
AVEVA Dynamic Simulation 2022 -> Change option.
Pre-Install Checklist
This section details the most common issues that may be encountered when installing AVEVA Dynamic
Simulation Software.
AVEVA Dynamic Simulation 2022 co-exists with previous, released versions of DYNSIM (6.2, 6.1, 6.0, 5.3.x, and
5.3). You do not need to uninstall previous versions. You do not need to un-install and re-install components or
prerequisite software that were successfully installed as part of previous full installs, such as Microsoft SQL
2014, .NET 4.7.2 or Microsoft Windows Installer 4.5.
NOTE: To avoid complications with the AVEVA Dynamic Simulation Bulk Configurator startup, Microsoft Excel
with Office 365 support (64-bit) software must be installed before installing AVEVA Dynamic Simulation software.
Open an Excel spreadsheet at least once to register the Excel product key
IMPORTANT: When the AVEVA Dynamic Simulation software installer is used with SCP software or TRISIM Plus®
software this AVEVA Dynamic Simulation software install is a subset of the total system install. Plan the system
configuration, and perform system installation in the correct order. When using this installer with SCP software,
please review the SCP Installation Guide before beginning system configuration and install. The AVEVA Dynamic
Simulation software 2022 installation is a subset of the procedures documented in the SCP Installation Guide.
Similarly, for TRISIM Plus software installations, the TRISIM Installation Guide should be reviewed before system
configuration and installation.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 9
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
Before you begin a new AVEVA Dynamic Simulation Software install
1. Ensure that you have administrative rights (Microsoft Windows security) for the machine on which you will
install or un-install AVEVA Dynamic Simulation Software.
2. AVEVA Dynamic Simulation Software requires Power User or Local Machine Administrator privileges to stop
and restart its services at runtime. Computers with SCP270 Software (CP Image) require Local Machine
Administrator privileges.
3. AVEVA Dynamic Simulation Software install testing has been performed on the following 64-bit operating
systems:
• Windows 10 Enterprise (20H2)
• Windows 10 Professional
• Windows 10 Enterprise, Japanese
• Windows 11 Enterprise (21H2)
• Windows Server 2016 Standard
• Windows Server 2019 Standard
Operating systems not explicitly tested may not work properly.
Note: AVEVA Dynamic Simulation 2022 is not supported on 32-bit Operating Systems.
4. Do not rename a machine with AVEVA Dynamic Simulation Software or any application with Microsoft SQL
Server installed. Use the following procedure:
• Back up your work.
• Un-install AVEVA Dynamic Simulation Software
• Reboot the machine.
• Rename the machine.
• Re-install AVEVA Dynamic Simulation Software.
• Restore your work.
5. Machine names must only include alphanumeric characters (A to Z and 0 to 9). Issues have been reported
for machines with special characters in machine names during installs. Consult your IT administrators to
ensure that your DNS Servers fully support those hostnames. Mixed case or lower-case machine names (a to
z) will, on certain occasions, cause issues with the MS SQL server naming.
6. If you are using FlexNet or TOKEN security, you will need the name of the FlexNet security server or fixed IP
address.
7. USB security hardware keys are no longer supported. For any assistance on USB support, please contact
AVEVA technical support.
8. If you have a firewall installed, it may interfere with the AVEVA Activation Manager and other AVEVA
Dynamic Simulation services. We recommend turning off your firewall. If disabling the firewall is not allowed,
put the firewall in "learning mode" the first time you start up AVEVA Dynamic Simulation applications, or
configure it to allow starting AVEVA Dynamic Simulation processes with dynamic port addresses.
9. Data Execution Prevention may cause problems with the AVEVA Dynamic Simulation services and installer.
Through the operating system’s Performance Options, under Data Execution Prevention, select Turn on DEP
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 10
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
for essential Windows programs and services only. For more information, refer to Microsoft Knowledge
Base article 875352.
10. Foxboro® I/A Series® processes MUST be disabled and stopped before installing or uninstalling AVEVA
Dynamic Simulation Software on I/A Series systems. If I/A Series processes are running, use the Control Panel
"Foxboro I/A" control to "Disable I/A Series auto login", then reboot I/A Series machine using Start->Run-"fox
shutdown 1 1 1" command and reboot the system before install AVEVA Dynamic Simulation Software.
11. Installing AVEVA Dynamic Simulation Software while SCP/TRISIM/Dynamic Simulation processes are running
will cause install issues. Before installing AVEVA Dynamic Simulation Software:
a. Stop SCP, TRISIM, and AVEVA Dynamic Simulation processes via normal shutdown.
b. Reset the services via the Host Configuration editor.
c. Exit the SCP launcher.
12. Installation of different versions of AVEVA Dynamic Simulation Software may cause the SIM4ME environment
variable to contain multiple paths. Before installing SCP Software, verify that the SIM4ME environment
variable contains a single unique path to the current AVEVA Dynamic Simulation install root (for example,
C:\SIMSCI\DSS63).
13. AVEVA Dynamic Simulation is not compatible with Windows sleep mode. Ensure that sleep mode is turned
off for all workstations hosting AVEVA Dynamic Simulation and any DSS engines.
AVEVA Dynamic Simulation Secure Deployment Guidelines
For maximum security, when installing AVEVA Dynamic Simulation, do the following:
• Do not install SQL Server
• Choose single box install option
• Do not open any external ports in your local firewall.
This will have all AVEVA Dynamic Simulation processes running at the user’s security level without external
connections. The following section provides a detailed instructions on these points.
SQL Server
With AVEVA Dynamic Simulation 2022, SQL Server is not needed to run AVEVA Dynamic Simulation. SQL Server is
only needed to evolve simulations from AVEVA Dynamic Simulation 5.3.2 and earlier. If you do need to migrate
pre AVEVA Dynamic Simulation 6.0 simulations to AVEVA Dynamic Simulation 2021 or later then install SQL
Server on a single machine and use that to migrate all necessary simulations.
Multibox Setup
If multiple machines are needed to run a simulation then the multi-box installation option is necessary. Some
ports will have to be opened in the machine firewalls to let the various machines communicate. For more
information on the minimum number of ports and how to select the specific port numbers, refer to Port Usage in
AVEVA Dynamic Simulation.
Installation Folder
For secure installation, install AVEVA Dynamic Simulation under the OS %Program Files%.
If you choose to install AVEVA Dynamic Simulation to a folder outside of %Program Files% and you wish to make
your installation more secure, ensure that write permission restrictions are applied on the folders where AVEVA
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 11
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
Dynamic Simulation binaries are installed. For example, if you install under C:\simsci\, then change the
permissions of all folders under C:\SimSci\DSS63, (except for C:\SimSci\DSS63\Simulations and
C:\SimSci\DSS63\User), to restrict write privileges only to the Administrators group.
Port Usage in AVEVA Dynamic Simulation
AVEVA Dynamic Simulation potentially uses quite a few IP ports depending on the number of engines in a
simulation. Each executable that functions as a CORBA server uses a unique IP port. This includes the
NamingService, ActivationManager, UtilityServer, SimExecutive, GUI, and each engine. Some large simulations
have more than 50 engines spread across several computers. By default, the NamingService uses port 10153 and
the other processes will use open ports above 50000. Also, the SMB port 445 might be used if a multibox
installation is chosen. It is possible to specify the IP ports used by all the processes, not just the NamingService.
For more information, refer to Setting CORBA IP Port Numbers in AVEVA Dynamic Simulation.
Setting CORBA IP Port Numbers in AVEVA Dynamic Simulation
ActivationManager and UtilityServer
These processes get the relevant arguments from the registry. Under the HKLM\SOFTWARE\SIMSCI\SIM4ME\
{version} folder, there is a string value named NameServiceInfo. This entry needs to be modified.
Commas are used instead of spaces to separate command line arguments. If you want to assign ports 56000 and
56001 to the ActivationManager and UtilityServer, the following update is required:
-ORBListenEndpoints,iiop://:56000/portspan=2
Note: You need to give these processes sequential port numbers. The 56000 is the base IP port and the
portspan=2 argument limits the port choices to 56000 and 56001. If the portspan is not set or portspan is set to
1, then one of the processes would fail on startup due to not finding an open port.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 12
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
SimExecutive and Engines
The Config_file.dat in C:\SimSci\DSS63\Servers\system needs to be edited to add the relevant argument. Each
engine type has section in config_file.dat and in these sections will be a startup_params line. For all engine types
the beginning of the line will look like:
startup_params=-ORBInitRef NameService=iioploc://%NSHOST%:%NSPORT%/NameService -ORBSvcConf
"C:\SimSci\DSS63\Servers\bin\Sim4meSVC.conf" -ORBDottedDecimalAddresses 0
the -ORBListenEndpoints argument should be added right after this. For the SimExecutive a single port is
acceptable:
startup_params=-ORBInitRef NameService=iioploc://%NSHOST%:%NSPORT%/NameService -ORBSvcConf
"C:\SimSci\DSS63\Servers\bin\Sim4meSVC.conf" -ORBDottedDecimalAddresses 0
-ORBListenEndpoints iiop://:10160
For each engine type the number of engines needs to be determined so the portspan can be set.
Note: For AVEVA Dynamic Simulation engines you will need two ports per engine. One for the edit engine and
one for the run engine. For a two AVEVA Dynamic Simulation engine simulations, you would set:
startup_params=-ORBInitRef NameService=iioploc://%NSHOST%:%NSPORT%/NameService -ORBSvcConf
"C:\SimSci\DSS63\Servers\bin\Sim4meSVC.conf" -ORBDottedDecimalAddresses 0
-ORBListenEndpoints iiop://:10161/portspan=4
Software Co-Existence
AVEVA Dynamic Simulation 2022 co-exists with DYNSIM 2021, 6.1, 6.0, and 5.3.x.
The following AVEVA products can co-exist with AVEVA Dynamic Simulation 2022:
• AVEVA PRO/II Simulation 2021
• AVEVA Process Optimization 2020
• PipePhase™ Pipeline Network Design 2021
• VISUAL FLARE™ Safety Relief Design 2021
PRO/II to DYNSIM (P2DS) Translator
Note: Ensure SQL Server is installed on your computer for translation.
The following versions of PRO/II translate into corresponding AVEVA Dynamic Simulation Software versions:
• AVEVA PRO/II Simulation 2021-> AVEVA Dynamic Simulation 2022
• AVEVA PRO/II Simulation 2020-> AVEVA Dynamic Simulation 2021
• PRO/II 10.2.2 -> AVEVA Dynamic Simulation 2021, DYNSIM Dynamic Simulation 6.1
• PRO/II 10.1 -> AVEVA Dynamic Simulation 2021, DYNSIM Dynamic Simulation 6.1, DYNSIM 6.0
NOTE: Translation from PRO/II 10.0 to DYNSIM Dynamic Simulation 6.1 will not work due to a known issue
which was fixed in PRO/II 10.1.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 13
AVEVA™ Dynamic Simulation Release Notes
AVEVA Dynamic Simulation 2022 Installation
Control Emulation and I/A Series Compatibility
At the time of release, AVEVA Dynamic Simulation 2022 is compatible with the following:
• AVEVA™ Simulation for Foxboro™ Control 2021 (SCP 4.1), AVEVA™ Simulation for Foxboro™ Control 4.0 (SCP
4.0)
• AVEVA™ Simulation for Triconex™ Systems 2022 (TRISIM 4.3), AVEVA™ Simulation for Triconex™ Systems
2020 (TRISIM 4.2)
Later versions of Control Emulation software should be compatible with AVEVA Dynamic Simulation 2022.
Visit Global Customer Support: https://softwaresupport.aveva.com/ and review SCP or TRISIM Release Notes
for a current compatibility matrix.
NOTE: Refer to the SCP and TRISIM Installation Guides for operating system and product compatibility.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 14
Summary of Features and Enhancements
The following section lists a brief introduction to the various features introduced in AVEVA Dynamic Simulation
2022. For more information, refer to the product documentation.
Infrastructure Enhancements
Upgrade to 64-bit architecture
AVEVA Dynamic Simulation engines, GUI and infrastructure now support 64-bit architecture only. Installation
on 32-bit Operating Systems is no longer supported.
Note: AVEVA OTS Engines install, however, continues to be a 32-bit installer.
• Separate kits for x86 and x64 DYNSIM install are now replaced with a single 64-bit installer.
• Going forward, only “DYNSIM” (64-bit) engine, is available. Separate “DYNSIM” (32-bit) and
“DYNSIM_x64” (64-bit) engines are no longer supported.
• Models from previous versions configured with “DYNSIM” (32-bit) engine and “DYNSIM_x64” (64-bit)
will be auto upgraded to “DYNSIM” (64-bit) engine.
Support for MS Office and Excel 64-bit version
• AVEVA Dynamic Simulation now works on 64-bit MS Office 365 Excel applications only.
• All Excel related applications such as Excel engine, Bulk configurator, Export to CSV, and other Third-party
tools interface will work with 64-bit Office versions only.
GUI Features
GUI Modernization
• AVEVA Dynamic Simulation User Interface has been updated as per the latest AVEVA Design System.
• As a part of the UI modernization, AVEVA Dynamic Simulation supports Light and Dark Themes. The default
Theme setting for AVEVA Dynamic Simulation is Light Theme and allows user to switch to Dark Theme from
the Settings tab.
• AVEVA Dynamic Simulation Theme application is independent of the Windows Theme. Changes to Windows
theme will not have any impact on the AVEVA Dynamic Simulation GUI behavior.
• Forms, behavior, and shape of the controls are similar to Microsoft Fluent UI Theme.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 15
AVEVA™ Dynamic Simulation Release Notes
Summary of Features and Enhancements
• Follows standardized Tab Design, Color, Table Formats, Fonts, etc.
Limitations
AVEVA Dynamic Simulation Theming will not be applied within flow sheet canvas, MTGUI, widgets, primitives.
Points to remember
• Background color for Trends, XY Plot can be customized from Draw Attributes with the default option
corresponding to Theme setting.
• For migrated models, Trends and Plots configured with background color will be retained.
• Theme settings are specific to the Windows user and the last open theme before exiting the previous session
will be retained.
• Before switching the Theme, the user must ensure that all changes are saved as open Windows, such as OEV,
DEW, Data Historian, etc., will get closed.
Introduction of Ribbon Bar
AVEVA Dynamic Simulation now comes with a Ribbon Bar having different tabs and all the existing menu bars
and toolbars from previous versions are grouped under new ribbon groupings.
Note: User can hide Ribbon bar by right clicking on the ribbon menu or the panel.
Quick Access Toolbar
For ease of access, AVEVA Dynamic Simulation allows user to add all Ribbon options to Quick Access toolbar.
Option to add items to quick access toolbar is available by right clicking of any ribbon group option. User can
remove the already added items from the Quick Access toolbar as well.
Simulation Control Panel
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 16
AVEVA™ Dynamic Simulation Release Notes
Summary of Features and Enhancements
• A new status panel named Simulation Control panel is introduced. It contains buttons for load, run, freeze,
single step, set speed.
• Simulation Control panel also displays simulation speed, simulation status, simulation name, IC/backtrack
information.
• IC/backtrack summary can be opened from the Simulation Control panel.
• Single Step button will run the model for one timestep with a single click (no need to toggle).
• Status of simulation such as Frozen, Running, IC saved will be displayed in the panel.
Miscellaneous UI changes
• A new Express tab is added and is home to commonly used ribbon items for ease of use
• A new Lists tab to display undo/redo actions, malfunctions pane, TPM pane (for instructor)
• Username and SimExecutive name moved to the bottom-right corner below message monitor.
Model Enhancements
Cryogenic Exchanger Enhancements
An improved Cryogenic Exchanger is now part of AVEVA Dynamic Simulation 2022. Modifications have been
made to compressible and incompressible dynamic options and holdup calculations. The improvements done as
part of this release are:
• Implement Advanced dynamics logic in Tube Pass in case of Compressible + Rigorous.
• Update of wall and pass temperatures during derivative calculations to avoid heat rate fluctuations with
Integrated Energy Balance algorithm.
• Correction is made in the definition of member variable used to define holdup protection in the
IntegratedEnergyBalance function which resolved the exception in case of Rigorous Compressible
configuration.
• Make sure the tube volume is updated during Load/LF in case of Spiral Wound Exchanger.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 17
AVEVA™ Dynamic Simulation Release Notes
Summary of Features and Enhancements
• Resolution of temperature crossover issue during a shutdown scenario with integrated energy balance and
Chen's correlation enabled.
• Resolution of reverse flow discrepancy with LM correlations in Tube Pass compared to Simple Conductance
when there is 100% vapor.
• Avoid Shah correlation during vaporization so that shut down scenario is run successfully.
• Correction in Uf calculation in TubePass Shah correlation to avoid fluctuations during MR and NG cutoff with
compressible and incompressible options.
• Resolution of flow fluctuation which should be zero when outlet valves are closed in case of LM correlations.
• Resolution of Plate-Fin exchanger issue of UFCalc not getting updated when vapor is greater than 95%.
Header Enhancement – Advanced Header
The following Header enhancements are introduced in AVEVA Dynamic Simulation 2022:
• Automatically transition between different algorithms based on process conditions and model state
• Avoid / handle failures without user intervention
• Consistent molar density from mass balance and the flash
• Volume sensitivity robustness during fast transition between phases
• Handle rapid pressure changes
• Handle zero derivative conditions in isolated headers to avoid pressure going beyond lower or higher limit
• Improve stability and accuracy for a small residence time system
• Improve speed by avoiding volume sensitivity calculations at steady state in case if Rigorous + Compressible
and Advanced options
• Remove/reduce the need for user to choose solution option
• Avoid breaking existing systems – current options are hidden in DEW but retained in OEV.
Invariant Co-ordinates for Compressor Performance Map
This feature enhancement allow users to
• Extend the Invariant scaling to surge calculations
• Handle non-monotonic surge curve
• Duplicate speeds in defining the surge curve
• Improve the accuracy of scaling to +/-2% of the literature values
• Extrapolate the speed based on reduced curves
Stream with Embedded Conductance
AVEVA Dynamic Simulation 2021 or earlier version architecture does not allow directly connecting two pressure
nodes with a stream. In P&IDs, two vessels (pressure nodes) may often be connected, with no physical
equipment in between. Users/migration tools are required to add non-existing flow devices (typically valves or
pipes) in the simulation.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 18
AVEVA™ Dynamic Simulation Release Notes
Summary of Features and Enhancements
The new feature allows intelligent P&IDs to get imported into AVEVA Dynamic Simulation 2022 using a model
generation tool. Using this feature, when a user connects two pressure nodes and enables the flow calculation
option, an embedded conductance sub-model is created within the stream model.
Thermodynamics Enhancements
Open Form VLLE and Super linear local flash
Existing VLLE Flash algorithm, i.e., NO TIER, has a few limitations such as failing to predict L1/L2 phase for some
flash conditions. Robustness issues are also seen with the traditional local flash (LF) when the component slate
contains more than 60 components.
To overcome the limitations,
• An alternate VLLE flash algorithm called “Open Form” is implemented.
• A method called Tangent Plane Distance Analysis (TPDA) is implemented for helping to predict missing liquid
phases(L1/L2) more accurately than NO TIER with LF.
• Super Linear Local Flash (SPLF) approach is introduced to solve the crash issue and also it can handle VLLE
with much larger component counts (150+) without any memory issue.
• From performance point of view, both need rigorous update, but SPLF requires less properties update during
rigorous update, hence would be faster in principle.
• NO TIER-RTSPLF algorithm is more robust in any of the OTS projects and do not encounter any convergence
issues or NAN values.
Simplified Flash Option Configuration
Flash algorithm parameters for different InternalPhases options are available to execute flash in various
operating conditions using particular algorithm as shown below:
• VLE Flash algorithm (0 – No Tier, 1 – Tier2, 2-Open Form)
• VLLE Flash algorithm (0 – No Tier, 2-Open Form)
• FREE_WATER/DECANT Flash algorithm (0 – No Tier, 2-Open Form)
User can set the above parameters per engine basis using the Engine Configuration option.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 19
AVEVA™ Dynamic Simulation Release Notes
Summary of Features and Enhancements
Miscellaneous Enhancements
AVEVA Learning Monitor 2022
A new tool to replace existing TPM and Score
• Can import TPM and Score templates
Modular template format
• Can have multiple TPM and Score modules in one Learning Monitor template
Separate application
• Learning Monitor templates and results are saved outside of *.js4m file
• More than one simulation can be in a learning monitor project
• Subscription based data collection to minimize impact on performance
• Can start, shutdown, and reset AVEVA Dynamic Simulation from AVEVA Learning Monitor
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 20
Known Issues
Message pop up while opening BulkConfigurator file
If you encounter the following error message, install VSTO assembly manually by double clicking
DSS.BulkConfigurator.vsto located at "C:\SIMSCI\DSS63\BulkConfigurator\bin".
If it fails to install, remove the "2.0" folder from C:\Users\<username>\AppData\Local\Apps folder and repeat
the previous step.
UOM issues upon migration with ElecSolve models.
Models created in or migrated to 5.3/5.3HF OR V_DES parameter values adjusted manually in 5.3 will have a
problem on migration to AVEVA Dynamic Simulation 2022. Solution is to use the AVEVA Dynamic Simulation
search tool to find entries of V_DES in the database. Inspect and correct the values manually (typically by a factor
of 1000) to match the 5.2.1 values. Migration from DYNSIM 5.2.1 or previous versions to AVEVA Dynamic
Simulation 2022 will not show this issue.
Float Point Errors during load or runtime
With the introduction of checks to eliminate "divide by zero" error, float point error warning messages might be
reported for some of the miscellaneous equations during load or during runtime in the message monitor. These
warnings do not have any impact on performance but might lead to deviation in steady-state values. In such
equations, add protection to the denominator to avoid division by zero. For example, to avoid zero Y values in
the equation X/Y, modify equation as X/(IF Y ==0, 0.001, Y).
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 21
AVEVA™ Dynamic Simulation Release Notes
Known Issues
Windows Look and Feel
The look and feel for object faceplates, sliders and others may not be the same in various Windows OS. It will not
have any impact on functionality. Consider changing theme or personalization to make it consistent with other
Operating Systems.
Pipe fitting calculations with exit effect
In DYNSIM 5.3.2, calculations for pipe fitting (K) has been modified. Exit effect value entered was taken as L/D
and corresponding "K" was calculated as K=f*(L/D). With modified calculations, exit effect value will be taken as
K. There might be a deviation in steady-state values for simulation having a pipe with exit effect upon migration
of simulations using versions prior to 5.3.2.
Flash statistics window response
In DYNSIM versions before 6.1, a slowdown was observed with value refresh in the Flash statistics window. This
issue has been addressed in AVEVA Dynamic Simulation 2022 by refreshing only the visible parameter values due
to which, while switching between internal tabs (performance, results, configuration) scroll bar will move to the
first flash instead of the selected flash. Also, scrolling the window will refresh the values gradually.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 22
Summary of Defects Resolved
The following is a selective list of customer-reported defects resolved in the AVEVA Dynamic Simulation v2022
release. For a complete list of defects resolved prior to AVEVA Dynamic Simulation v2022, please refer to the
Release notes of previous versions.
S. No
ID
Title
1
755063
Disturbance in steady state when a stable IC is loaded. Issue with Heat Exchanger.
2
916329/949 Issue with a Sour Water Unit in AVEVA Dynamic Simulation v 6.2. Simulation speed
501/998586 drops and steady state not maintained.
3
949503/845
Resolve copyright information on the AVEVA Dynamic Simulation Splash screen.
679
4
949502/829 Old product name "DYNSIM" is shown in Bulk configurator spreadsheet instead of
445
AVEVA Dynamic Simulation.
5
949506/938 Error encountered while performing copy/paste states in AVEVA Dynamic Simulation
958/
v 6.2.
6
949505/924 Changes in Rigorous Furnaces with Custom Flow order in AVEVA Dynamic Simulation
068
6.2
7
946627
LF SS: Issue with QVSTD with LF
8
914375
Temperature cross at Utility Exchanger - Pipe configured with Heat stream with more
than one holdup.
9
916348
Flash issues in Header M3 and Tank M3 objects.
10
837551
Changing the toolbar to navigation in AVEVA Dynamic Simulation session on remote
machine crashing AVEVA Dynamic Simulation session on Master Machine
11
836738
Issue with Super User Environment
12
755066
Flash Failure at M3 header.
13
1063344
Memory leak issue with stalled engine error in a AVEVA Dynamic Simulation power
model
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 23
AVEVA™ Dynamic Simulation Release Notes
Summary of Defects Resolved
S. No
ID
Title
14
978981
Heat exchangers iterations are High and simulation speed is decreasing.
15
1102069
Error encountered if input sample time by Parameter reference.
16
848609
AVEVA Dynamic Simulation Launch error - Error messages not useful to the user
17
923695
Temperature drops at Header.
18
1325929
Unhandled Exception while merging XMLs using the AVEVA Dynamic Simulation
Merge tool
19
1343825
Network failures are observed at lower pressures due to sudden prediction of liquid
in drum
20
1365555
Schema upgrade error encountered while migrating model from DYNSIM v5.32. to
AVEVA Dynamic Simulation v6.2.
21
1226250
Failures are observed while running Scenarios 40.
22
1217180
Higher pressure bound warnings are observed while running Scenario 32
23
1436547
Nan Issue occurring with expander model
24
755114
[Plate-Fin Exchanger] Cryogenic Exchanger UfCalc Issue
25
1440327
When model objects are renamed sometimes, they are corrupted and seen as
miscellaneous equation blocks.
26
755127
Issue With Slate Change in DYNSIM v6.1HF: Nan in density despite successful flash
solution
27
755070
Density for Methane rich composition becomes not defined (nan) at 0 deg C.
28
1491553
[Thermo#1370946] Flash resulting in nan values in header model
29
1577010
Flash issue with expander model
30
1488134
Abnormal flash composition being sent to flash
31
755290
Incorrect BIP data for EO/H2O pair
32
755075
LF is needed after loading IC to avoid model crash in BCEP LAU simulation
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 24
AVEVA™ Dynamic Simulation Release Notes
Summary of Defects Resolved
S. No
ID
Title
33
1637293
[Tech Pubs] Typo error in the Getting Started Guide related to processor
34
1685264
Engine level TMIN not used as default for ThermoInterface TMIN everywhere.
35
1610572
Temperature drop issue with VLE flash (Tier2) with PH spec using PR for vapor, NRTL
for liquid in LT+RF mode
36
1683035
Temperature drop observed with flashes during lineup of carbonate solution
37
1687278
Temperature raise observed with flashes during shutdown of EO flow
38
755212
"ACCESS VIOLATION" error in AVEVA Dynamic Simulation model.
39
755110
DYNSIM LF hangs when I switch VLLE algorithm from NOTIER to OPEN FORM
40
1526722
Header model downstream results are unchanged during transient change.
41
1686976
Exception error of the AVEVA Dynamic Simulation engine while loading the model in
AVEVA Dynamic Simulation v6.2.
42
1685667
Stream temperature after stream receive when connected to different engine does
not show ambient temperature when there is no flow
43
1636480
Unable to copy multiple rows from a text editor and paste multiple rows into the OEV
window
44
1769423
Review and correct the notes on PID DEW and Reference Manual
45
755969
Issue with Nitrogen in a vacuum-packed distillation column
46
755471
Model convergence issue in People gas model
47
846176
Bug in Rigorous Furnace DEW - Flue Gas Convection Pass J changes automatically,
every time DEW apply button is used.
48
1702794
[Chimney tray DEW] Button for entering data for tray and Basic tab status show data
as incomplete even though all the required data is entered.
49
756100
Inconsistent flash results for HEATEXCHANGER with LAST_STEP Flash Estimation
Method.
50
1498300
L2 phase is not seen during startup in a drum having VLLE and LT+RF.
51
1407429
Error: unable to Parse data in set data. Pasting an equation in comments section
column giving this error.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 25
AVEVA™ Dynamic Simulation Release Notes
Summary of Defects Resolved
S. No
ID
Title
52
1585495
Flash results difference in WHPA project.
53
1839084
Specific value bundle issue in Separator observed when heat stream is connected on
right-side of weir.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 26
Summary of Defects and Issues
This list is published at the time of release. For the latest information, please visit our website http://
www.aveva.com and see the support section to find AVEVA Dynamic Simulation Software Knowledge Base and
updated Bug list. Registration is required to use this site.
S. No
ID
Title
1
762318
LFCR#5242 -- Flash doesn't give consistent density for same state VLE flash (Tier2)
with PH spec using SRK method in RT+RF mode at P = 33796.23 kPa, H = 6323.1943
kJ/kg-mol
2
762571
BI1#5793 -- Issue in pressurizing demethanizer tower
3
762596
LFCR#5427 -- Follow up of LFCR#5419. Separator doesn't handle liquid phase switch
cleanly
4
762831
[Free water issue - Resolved with No Ter and Open Form RT+RF] BI1#5843 -- Presence
if SOLIDS in in Drum & separator object having flash issues with LT+RF option.
5
762888
LFCR#5414 -- Flash jumps from 4% vapor to 0% vapor.
6
762854
Difference in flash results between VLE and VLWE/VLLE (Notier and Tier2) with PU
flash at P=771.643 kpa U= 24762.99 kj/kgmole with SRK method
7
756094
Flash solves failed in DYNSIM v5.3.2 for Roaster DMH OTS M3 Separator
8
755996
An unrecoverable error occurred during LF.
9
756088
Point monitor shows different value for pressure compared to actual value in AVEVA
Dynamic Simulation when PAMB is different from default value
10
755510
In DYNSIM 5.3.2HF, Tower model is getting disturbed from steady state after LF
11
756091
DYNSIM v6.0 - Multi Heat Exchanger vapor fraction issue with New Algorithm
12
756085
Furnace draft pressures in gauge values display is not consistent with the actual
calculated value
13
755292
Incorrect VLE phase Prediction calculation when inventorying from a N2 blanketed
state
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 27
AVEVA™ Dynamic Simulation Release Notes
Summary of Defects and Issues
S. No
ID
Title
14
755215
AVEVA Dynamic Simulation Comparison Tool: Mark up XML back option is not
working with Instance Tree
15
755079
Free Water flash failures observed
16
755208
Thermo VLE/VLWE: More iterations with VLE internal phases
17
755130
Issue when loading IC - some values are not restored
18
831512
Memory Allocation issue in DYNSIM v6.1 HF
19
833136
Severe error during calculation due to Special property
20
857462
PROII results not matching with AVEVA Dynamic Simulation using Refprop library.
21
947218
In DYNSIM v5.3.1 and v5.3.2 in source model with PT configuration on changing T the
vf value is incorrect with Local thermo
22
978673
In AVEVA Dynamic Simulation v6.2, pipe with holdup having LT-RF configuration does
RU flash is giving different results on loading SS IC.
23
978683
In AVEVA Dynamic Simulation v6.2, pipe with holdup having RT-RF configuration does
RU flash is not giving correct results. With slight change in R and U spec the P, T and vf
value after flash changes drastically.
24
1065939
Sudden temperature rise observed through header which is not expected.
25
1217386
Modified description of a parameter in TPM is not reflecting in TPM report. First bad
6.0 version
26
1294543
Trends to reappear after DYNSIM v 5.3.2HF upgrade to DYNSIM v6.x.
27
1295431
AVEVA Dynamic Simulation v6.2 - Issue with special characters.
28
1298855
Metal casing model can cause exception during pre-process
29
1362425
Flash giving Temperature drop with water introduced into column
30
1371517
Difference in results between Local thermo and Rigorous thermo with respect to
temperature
31
1433364
Surge controller: Faceplate GUI issue in Manual Mode. Manual output is not pointing
to the correct value on GUI
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 28
AVEVA™ Dynamic Simulation Release Notes
Summary of Defects and Issues
S. No
ID
Title
32
1656992
RTRF flash failure issue with PH spec using PR for vapor, NRTL for liquid
33
1665089
When an IC saved with good conditions is loaded and run it gives many flash failures
34
1752837
Model speed goes to less than 100% while running one scenario DEA Absorber
column
35
1766414
DSwitch faceplate doesn't work correctly with runtime license.
36
1806992
Enabling the Show Grid lines option is freezing the GUI
37
1813157
Flash failing with VLLE in DYNSIM v5.3.1.
38
1828476
Flash issues with VLWE flash results in drum in DYNSIM v5.3.1.
Version 2022
© 2022 AVEVA Group plc and its subsidiaries. All rights reserved.
Page 29
Where to Find AVEVA Dynamic Simulation
Software Documentation
Documentation Included with this Package in Installation Media
• Release Notes for AVEVA Dynamic Simulation Software 2022(this document)
• Getting Started with AVEVA Dynamic Simulation
Printed Documentation Included with this Package
• AVEVA Dynamic Simulation Quick Install Guide
Online Documentation
• AVEVA Dynamic Simulation User Guide
• Getting Started with AVEVA Dynamic Simulation
• Reference Manuals for Model Libraries