Data Sheet RCUS38S

advertisement
Page 5 of 8
PT. YOKOGAWA INDONESIA
MS Code:
Base Model:
SPECIFICATION
Model
RCUS38S-50BA21-0C52-FF11-4-M21/TC
RC
SUFFIX
RC
Coriolis Flowmeter
DESCRIPTION
Coriolis Flowmeter
Transmitter
U
Ultimate (high function)
Sensor
S
Supreme
Meter Size
S
Nominal mass flow : 4000 kg/h
Maximum mass flow: 5000 kg/h
Material Wetted Parts
S
Measuring tubes: SS316L
Process connections: stainless steel 1.4404/316
Process Conection Size
-50
DN50, 2"
Process Connection Type
BA2
ASME Flange Class 300, RF
Sensor Housing Material
1
SS316L
Process Fluid Temperature
Range
-0
Standard, integral type: -50 – 150 °C (-58 – 302 °F)
Mass Flow and Density Accuracy
C5
Liquid: 0.1 % maximum mass flow deviation Dflat, 2 g/l den- sity deviation
Design and Housing
2
Integral Type with anti Corrossion
Explosion-proof Approval
Cable Entries
Communication Type and I/O
-FF1
-4
-M2
FM Exproof Model
ISO M20x1.5
Modbus output,1 passive pulse or status output, 1 active current input
Display
1
With display
Tube Size
-
Diameter : 3/32"
/TC
Tube health check
OPTIONAL SPECIFICATION
Option 1