EDITOR HFe 401 – HFe 801 „ Made in Germany ” Digital Highly Frenquency Generators for X-Ray Exposures and Digital Radiography High economical A quality product for highest requirements Routine diagnostics Investment in the future Optimum constrution Highly developed electronics complement the most up-to-date converter technology: Tomography Multi-microprocessor technology Series exposure technology Digital automatic exposure control, microprocessor controlled Digital Radiography Digital spot-film-technique Digital High Frequency Generators for Radioscopy Prefered subsystems: High speed starter for X-Ray tubes Programmable exposure technique Pulsation 100 kHz Printer for area dosage product Modular construction Remote control for automatic organ selection Data interface-RS232C Generator dimensions First-class product with optimal operating comfort for the follwing applications: Programmed organ parameters save time and reduce the number of repeated exposures. Expansion for a second X-Ray tube assembly Measuring system for area dosage product Special techniques Maximum operating comfort Height Width Depht 0-point mode: organ selection with or without falling load Routine diagnostics A HFe 401 – HFe 601 30 cm 90 cm 43 cm Tomography B HFe 401 – HFe 601 70 cm 53 cm 45 cm 1-point mode: Tube voltage can be freely selected, falling load, with automatic exposure control Digital image processing Pulsed exposure C HFe 401 – HFe 801 97 cm 55 cm 49 cm Digital Radiography D HFe 401 – HFe 801 97 cm 55 cm 49 cm 2-point mode: Tube voltage and mAs product can be freely selected, with or without automatic exposure control Digital spot-film-technique Digital Subtractions-Angiography 3-point mode: Tube voltage, tube current and switching time can be freely selected, with or without automatic exposure control Routine diagnostics Automatic organ library HFe 401 – HFe 601 f. e. in combination with the Bucky table HFe 401 – HFe 601 Tomography HFe 401 – HFe 801 HFe 401 – HFe 601 A Pulsation 100 kHz Automatic exposure control B Integrated area dosemeter C Automatic organ library Automatic exposure control HFe 401 – HFe 801 Series exposure technology Automatic dose regulation Digital spot-filmtechnique Integrated area dosemeter Digital SubstractionsAngiography D High speed anode module 150 Hz EDITOR HFe 401 – HFe 801 „ Made in Germany ” Technical Data Product Range Editor HFe 401 - HFe 801 mA / kW at 60 80 100 125 150 kV kV kV kV kV Continuous falling load EDITOR EDITOR EDITOR HFe 401 HFe 501 HFe 601 HFe 801 40 kW 50 kW 65 kW 80 kW 500 500 400 320 266 / / / / / 30 40 40 40 40 630 630 500 400 330 / / / / / 38 50 50 50 50 800 800 650 520 430 / / / / / 48 64 65 65 65 800 800 800 640 530 / / / / / 48 64 80 80 80 Yes Yes Yes Yes kV range during exposure kV steps or in 40-150 kV 1 kV 27 steps 40-150 kV 1 kV 27 steps 40-150 kV 1 kV 27 steps 40-150 kV 1 kV 27 steps Pulsation 100 kHz 100 kHz 100 kHz 100 kHz mA range during exposure in 10- 500 mA 18 steps 10- 650 mA 19 steps 10- 800 mA 20 steps 10- 800 mA 20 steps ms range during exposure in 1- 6300 ms 38 steps 1- 6300 ms 38 steps 1- 6300 ms 38 steps 1- 6300 ms 38 steps mAs range in 0.5- 600 mAs 32 steps 0.5- 600 mAs 32 steps 0.5- 600 mAs 32 steps 0.5- 600 mAs 32 steps mAs range (optional) in 0.5-1000 mAs 34 steps 0.5-1000 mAs 34 steps 0.5-1000 mAs 34 steps 0.5-1000 mAs 34 steps kV range during exposure in steps 40-125 kV 1 kV 40-125 kV 1 kV 40-125 kV 1 kV 40-125 kV 1 kV mA range during exposure (high current exposure) (pulsed exposure) 0.5- 5.0 mA (2-10 mA) (10-200 mA) 0.5- 5.0 mA (2-10 mA) (10-200 mA) 0.5- 5.0 mA (2-10 mA) (10-200 mA) 0.5- 5.0 mA (2-10 mA) (10-200 mA) Automatic dose regulation Yes Yes Yes Yes Imaging rate (pulse per sec.) 50 50 50 50 Automatic exposure control Optional Optional Optional Optional Dose area product measure systems Optional Optional Optional Optional RS232 RS232 RS232 RS232 400 V AC 50/60 Hz 3PH+N 400 V AC 50/60 Hz 3PH+N 400 V AC 50/60 Hz 3PH+N 400 V AC 50/60 Hz 3PH+N Mains voltage per phase 0,3 Ω 0,3 Ω 0,2 Ω 0,12 Ω Mains fuses, slow-blow 35 A 35 A 50 A 50 A 24 kVA 24 kVA 35 kVA 44 kVA Printer and PC-Interface Linevoltage, Linefrequency, Line connector Nominal power consuption Installation and Service 6 cm 44 cm For ease of access and cost effective servicing all components are mounted on printed circuit boards and are housed in an electronics cabinet. – is certified according to EN ISO 9001: 2000 and DIN EN ISO 13485:2003. Generators carrying the CE-1275 symbol fulfil the European Union guideline 93 / 42 / EEC. EDITOR Equipment subject to change without notice. All rights reserved. Reproduction in any form or the use of extracts require the prior agreement of K&S Röntgenwerk Bochum GmbH & Co. KG. Josef-Baumann-Straße 23 D- 44805 Bochum Phone +49 (0) 2 34 / 8 79 06 -0 Fax +49 (0) 2 34 / 8 79 06 -11 Internet: www.roentgenwerk.de E-Mail: info@roentgenwerk.de witzgall-design.de 10/2007 Power rating EDITOR 34,5 cm Generator High Frequency Generators HFe 401 – HFe 801