Combo Products Issued by YAMAHA CS Strategy & Planning Department Cause of FAIL Result of the CPLD Test Program (7-3) Issued: 2016/04/21 Rev.1 Rev.2 Rev.3 TF1; TF3; TF5 ■Product Category 3:Combo Products ■Model TF1, TF3, TF5 Content ■Purpose ■Reference The CPLD PLL testing needs to have the NY64-D card installed in the option card slot. This information was not described in the service manual and will be added. On page 146 in the Service Manual, "FAIL: PLL" is displayed In the PLL inspection (Test program 7-3-4) when the NY64-D card is not installed. Because the CPLD PLL testing needs to have the NY64-D card installed in the option card slot. ■Application to production: Parts list ■Parts list ■Parts detail ■Attached file ■Bulletin No. 2036 Using part(s): Not use