INSPECTION OF: FIRE INSPECTION INSPECTION METHOD TEMPLATE SANS 0400 SECTION T AS PER: GENERAL Client moving in.wooden doors Area dived by wooden walls Clean and well illuminated SAFETY DISTANCES Separate from other parts of the building ie business same entrance and exit FIRE RESISTANCE OF EXTERNAL WALLS External walls brick and motar Internal load bearing walls brick and motar Partitions are dry wall /rhinoboard OCCUPANCIES IN BUILDINGS Fashion design business next door FIRE PERFORMANCE GENERAL No sprinklers All signages for ohs needed And emergency signs to be installed 1x 2.5 dcp to be mounted FIRE RESISTANCE OF OCCUPANCY AND DIVISION SEPERATING ELEMENTS Walls are a minimum of 5 hour burn rate Partition are 30 min burn rate DGA and RSS Training Academy Page 1 of 9 FIRE STABILITY OF STRUCTURAL ELEMENTS OR COMPONENTS Medium computers hard drives extension cords ,cellphone plugs 15 students at time PARTITION WALLS AND PARTITIONS Brick PROTECTION OF OPENINGS Burglar guards of flat bar 1 to have emergency opening for escape RAISED ACCESS AND SUSPENDED FLOORS OF COMBUSTIBLE MATERIALS None ROOF ASSEMBLIES AND COVERINGS No trap door, solid concrete CEILINGS Concrete ceiling FLOOR COVERINGS Veniolium -worn out, natural pathways-suggestion of interlocking rubber mat as over carpet usage Page 2 of 9 WALL FINISHES Good condition painted PROVISION OF ESCAPE ROUTES Only one corridor to stay away Signage to be installed EXIT DOORS Same as entrance door FEEDER ROUTES Only one corridor from lift and stairs to business front door EMERGENCY ROUTES Need to be marked (signage to be installed) Emergency evacuation plan to be drawn Emergency tel no in place DIMENSIONS OF COMPONENTS OF ESCAPE ROUTES Corridor no extra lighting No numbering of floors Hose reels to be services 08/23 FE Missing Doors unmarked Client on second floor,mainsecurity on 4th floor,8 floor in total WIDTH OF ESCAPE ROUTES 1.5 meters Page 3 of 9 BASEMENTS None STAIRWAYS AND OTHER CHANGES OF LEVEL ALONG ESCAPE ROUTES Main staircase in use VENTILATION OF STAIRWAYS IN AN EMERGENCY ROUTE None PRESSURIZATION OF STAIRWAYS IN AN EMERGENCY ROUTE None OPENING IN FLOORS None EXTERNAL STAIRWAYS AND PASSAGES None LOBBIES FOYERS AND VESTIBULES Clean need correct signage and marking as discussed with client Page 4 of 9 MARKINGS AND SIGNPOSTING Not be placed LIGHTING OF FEEDER AND EMERGENCY ROUTES None FIRE DETECTION AND ALARM SYSTEMS Building use a siren for fire emergency Client have a first aid bag with burns kit Suggested regulation 3 box PROVISION OF FIRE FIGHTING EQUIPMENT One dcp 2,5 kg to be mounted correctly One co2 2kg to be placed in computer lab One 9kg dcp for complete coverage as backup WATER RETICULATION FOR FIRE FIGHTING PURPOSES Hose reel in corridor ,internal hydrant in corridor HOSE REELS Two hose reels to be serviced august 2023 HYDRANTS Internal hydrant Page 5 of 9 SPRINKLER SYSTEMS None PORTABLE FIRE EXTINQUISHERS Require 1 co2 2kg for computer lab MOBILE FIRE EXTINGUISHERS One in place 9kg needed as a backup Co2 as a suggestion FIRE STOPPING OF INACCESSIBLE CONCEALED SPACES Outside area for emergency exit PROTECTION IN SERVICE SHAFTS Lifts SERVICES IN STRUCTURAL OR SEPERATING ELEMENTS None only stairs SMOKE CONTROL Natural ventilation Doors to windoors Page 6 of 9 AIR-CONDITIONING AND VENTILATION SYSTEMS None NO SMOKING SIGNS No smoking signs,need to be placed LIFT SHAFTS One main set in building LIFT One good condition FIREMEN’S LIFT None STRETCHER LIFT None STAGE AND BACKSTAGE AREAS None Page 7 of 9 SEATING ARRANGEMENTS IN AUDITORIA OR HALLS ON GRANDSTANDS None PARKING GARAGES None OPERATING THEATRES AND INTENSIVE CARE UNITS None INSTALLATION OF LIQUID FUEL DISPENSING PUMPS AND TANKS None INSTALLATION OF OTHER TANKS None ACCESS TO BUILDINGS FOR FIRE FIGHING AND RESCUE PURPOSES Stairways, landing area outside of second floor Mountain rescue number available PRESUMED FIRE RESISTANCE OF BUILDING MATERIALS AND COMPONENTS 2 hours breakthrough Page 8 of 9 NON-COMBUSTIBLE BUILDING MATERIALS Brick and motar SURFACE FIRE INDEX OF MATERIALS Medium FIRE INDEX OF FLOOR COVERINGS Low PHOTO: 5 photographs taken WRIITEN: written report LINE MANAGER: INSPECTOR: DATE TIME: OWNERS OR REPRESENTATIVE SIGNATURE: Signed on hard copy above document to be emailed to management Page 9 of 9