Commissioning mcBSC DN0982859 Issue 01G Approval Date 2014-06-30 Commissioning mcBSC The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Solutions and Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Solutions and Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Solutions and Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Solutions and Networks and the customer. However, Nokia Solutions and Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Solutions and Networks will, if deemed necessary by Nokia Solutions and Networks, explain issues which may not be covered by the document. Nokia Solutions and Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Solutions and Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. NSN is a trademark of Nokia Solutions and Networks. Nokia is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Solutions and Networks 2014. All rights reserved f Important Notice on Product Safety This product may present safety risks due to laser, electricity, heat, and other sources of danger. Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product. The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set. Nokia Solutions and Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Solutions and Networks for any additional information. 2 DN0982859 Issue: 01G Commissioning mcBSC Table of Contents This document has 145 pages Summary of changes..................................................................... 7 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 Overview of commissioning standalone mcBSC configurations.... 8 Prerequisites.................................................................................. 8 Documents..................................................................................... 8 Software......................................................................................... 8 Testing............................................................................................9 Equipment needed for the initial inspection and testing.................9 Tools............................................................................................... 9 Complementary information......................................................... 10 2 2.1 Checking hardware.......................................................................11 Checking interconnection cables..................................................11 3 3.1 3.1.1 3.2 3.2.1 3.2.1.1 3.2.1.2 3.2.1.3 3.2.1.4 3.2.2 3.2.2.1 3.2.3 3.2.3.1 3.2.4 3.2.4.1 3.2.5 3.2.6 3.2.6.1 3.2.7 3.2.7.1 3.2.8 3.2.8.1 3.2.9 3.2.10 3.2.10.1 3.2.11 Initial inspections..........................................................................16 Visual Inspection.......................................................................... 16 Verify LMP MAC address............................................................. 16 Checking the settings and configuration...................................... 16 Connection to BCN LMP.............................................................. 16 Connection to the serial port........................................................ 17 Steps ........................................................................................... 18 Connection to MGT port...............................................................18 Steps ........................................................................................... 18 Checking the MAC Address of the BCN...................................... 19 ..................................................................................................... 19 Power on for BCN BOXes............................................................19 Steps............................................................................................ 19 Checking BCN BOX configuration............................................... 20 Steps............................................................................................ 20 Checking the location of OMU..................................................... 21 Checking PCIe switch configuration.............................................21 Steps ........................................................................................... 21 Checking the delivery specific Network Element number............ 22 Steps ........................................................................................... 22 Checking FRU data of equipped units......................................... 22 ..................................................................................................... 22 Checking the sensors...................................................................23 Checking Eth (ethernet) settings of BCN boxes...........................23 Steps ........................................................................................... 23 Checking bootscript and card_config for add-in cards cat /etc/ipmi/mch.conf........................................................................ 25 Activate the changes and take the new configuration into use.... 26 ..................................................................................................... 26 3.2.12 3.2.12.1 Issue: 01G DN0982859 3 Commissioning mcBSC 4 3.2.13 3.2.13.1 3.2.13.2 3.2.14 Checking the BCN switch configuration....................................... 28 Check main switch configuration:.................................................28 Check extension switch configuration from BOX1 and BOX2:.....29 Change the flash bank 1 to active ...............................................30 4 Commissioning BSAC-A.............................................................. 32 5 Monitoring mcBSC startup........................................................... 36 6 Inspecting EMB connections........................................................44 7 Checking the I/O system of mcBSC.............................................48 8 Checking the hardware configuration of mcBSC......................... 54 9 Checking the power system and diagnostics of mcBSC..............55 10 Verifying the software versions of mcBSC................................... 60 11 Copying additional software and setting the time zone in mcBSC... 62 12 12.1 12.2 12.2.1 12.2.2 12.2.3 12.2.4 12.2.5 12.2.6 12.2.7 12.2.8 12.2.9 12.2.10 12.2.11 12.2.12 12.2.13 12.2.14 12.2.15 Appendix...................................................................................... 63 Verifying LEDs..............................................................................63 Factory switch configuration.........................................................63 BOX 1 main switch.......................................................................64 BOX 2 main switch.......................................................................70 BOX 1 and 2 extension switch..................................................... 76 TRX extension box main switch................................................... 78 PS extension box main switch..................................................... 84 BCN-B BOX 1 main switch...........................................................90 BCN-B BOX 1 extension switch................................................... 97 BCN-B BOX 2 main switch...........................................................99 BCN-B BOX 2 extension switch................................................. 106 BCN-B TRX extension box main switch.....................................108 BCN-B 2.TRX extension box main switch.................................. 115 BCN-B 3.TRX extension box main switch..................................121 BCN-B 1. PS extension box main switch................................... 127 BCN-B 2.PS extension box main switch.................................... 133 BCN-B 3.PS extension box main switch.................................... 139 DN0982859 Issue: 01G Commissioning mcBSC List of Figures Issue: 01G Figure 1 MAC Address on BCN box sticker......................................................16 Figure 2 LMP connection of BCN-A..................................................................17 DN0982859 5 Commissioning mcBSC List of Tables 6 Table 1 Site connectivity with interfaces.......................................................... 11 Table 2 SFP types used in mcBSC................................................................. 11 Table 3 Add in card locations in different BCN-A modules..............................13 Table 4 Add in card locations in different BCN-B modules..............................13 Table 5 Requirements for the power entry DC Interface A (PSU)...................15 Table 6 Terminal settings.................................................................................17 Table 7 Pin order of the RJ-45 serial port connector....................................... 17 Table 8 MGT connection IP addresses........................................................... 18 Table 9 Equipped units adresses.................................................................... 23 Table 10 Box mcBSC module mapping.............................................................27 Table 11 mcBSC Ethernet Message Bus addresses........................................ 44 Table 12 BCN LED status................................................................................. 63 Table 13 LED status according to unit working state........................................ 63 DN0982859 Issue: 01G Commissioning mcBSC Summary of changes Summary of changes Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues. Changes between issues 01G(2014/06/30, RG30(BSS)) and 01F(2014/02/20, RG30(BSS)) • Document has been restructured. Changes between issues 01F(2014/02/20, RG30(BSS)) and 01E(2013/01/02, RG20(BSS)) • Document has been restructured. Changes between issues 01E(2013/01/02, RG20(BSS)) and 01D(2012/11/19, RG20(BSS)) Overview of commissioning standalone mcBSC configurations (1) • Document restructured. Initial inspections (2) • Issue: 01G Chapter Checking the BIOS Settings has been removed as BIOS settings are not supposed to be modified. DN0982859 7 Overview of commissioning standalone mcBSC configurations Commissioning mcBSC 1 Overview of commissioning standalone mcBSC configurations These instructions are intended to be used in the commissioning of a standalone Multicontroller BSC (mcBSC) system in the final location of the mcBSC. The commissioning tasks are done to ensure that the hardware and software of the mcBSC have been correctly installed and the mcBSC is functional. They can be used with the ANSI or ETSI environment. The mcBSC running with S16.1 release supports Packet Abis, AoIP and GPoIP features. The mcBSC can be commissioned as standalone mcBSC and its capacity can be increased by addling PS/TRX extension. For more details on configuring standalone mcBSC and standalone mcBSC with PS/TRX extension, refer to Creating and Managing mcBSC Hardware. After commissioning, the mcBSC is ready to be integrated with the other elements of the network. 1.1 Prerequisites • • • • • The mcBSC has passed the factory acceptance tests. The installation has to be accepted. At least the files associated with the configuration are ready on the hard disks and flash banks of the mcBSC. The site has been built and prepared according to mcBSC, Rel. S16.1, Site Documentation. The basic knowledge of Linux is necessary to perform described operations. 1.2 Documents • • Pre-processor Program Information In S16.1 Release Documentation Latest GSM/EDGE BSS, Operating Documentation 1.3 Software All the software that belongs to the mcBSC must be ready on the hard disks and flash banks of the system before starting the commissioning tests. If there is newer SW available than what is installed in the mcBSC disk, the mcBSC must be commissioned with the same SW that is installed on the disks. The newer SW is installed before the integration of the mcBSC. In the final mcBSC site the tests which, according to the test logs delivered with the hardware, have already been performed at the test field, do not necessarily have to be performed. 8 DN0982859 Issue: 01G Commissioning mcBSC Overview of commissioning standalone mcBSC configurations 1.4 Testing The purpose of the commissioning tests is to ensure that the mcBSC will operate correctly in the GSM network. When the commissioning tests have been performed in an acceptable manner, the mcBSC can be taken into traffic. Depending on the configuration, the commissioning of mcBSC takes around 3-5 working days. The Serial Number and Identification codes of the network element (NE) must be fill using NetAct HW Inventory during commissioning of NEs (at least) according to Creating and Managing mcBSC Hardware. This is normally done during factory testing before the delivery for new deliveries, but in extensions this must be done on site before commissioning testing. It is important to have an overall view of the commissioning. Therefore, we recommend that you read the instructions carefully before starting. Commissioning test arrangements testing of the mcBSC can be started when the installation has been checked. Any detected faults are reported with a problem report which is sent to the Customer Service Centre. Test logs are filled in during the testing. The test logs can be found in mcBSC commissioning test logs. 1.5 Equipment needed for the initial inspection and testing A computer with: • • • • RS232 cable (RJ45 to 0-pol female) Ethernet interface Terminal application (HIT, Putty) USB Serial Parallel Adapter 1.6 Tools 1. 2. 3. 4. 5. 6. 7. 8. Issue: 01G Two terminals Hex calculator Tool set for commissioning engineer, NSN code: CS77580.05 Release documentation on PC New software on PC All delivered Maintenance Packets (installed after the commissioning) Customer Specific files including PRFILE, FIFILE, and licence files Empty memory stick for BSC commissioning procedure DN0982859 9 Overview of commissioning standalone mcBSC configurations Commissioning mcBSC 1.7 Complementary information Troubleshooting information can be found in Start-up fault conditions in Printouts of Starting Phases in DMX Units of DX 200, under Reference/Printouts/Error codes in the PDF view. 10 DN0982859 Issue: 01G Commissioning mcBSC Checking hardware 2 Checking hardware This procedure enables you to check the hardware functioning in the commissioning tests. The following items are checked in mcBSC: • • • • HiGig, Synchronization, and SAS cabling Interchangeability codes DIP switches Power supply 2.1 Checking interconnection cables Steps 1 Verify that the controller modules are interconnected by HiGig cables. 2 Verify the connection between the Site equipment and mcBSC. The number of connections required per module depends on the capacity of the interface as given in the below table. Table 1 g Site connectivity with interfaces Interface capacity Required connections per module 1 and 2 1 GE 5 10 GE 1 PTUM synchronization cards need individual connection of 1 GE to Site equipment. 3 Verify external LAN interface and connection types. Check that the connection types are as given in the following table: Table 2 Issue: 01G SFP types used in mcBSC SFP Type Signal Range Connector SFPPSM Single- mode 10GBase-LR/LW 10km LC SFPPMM Multi-mode 10GBase-SR/SW 300m LC SFPF2L Multi-mode 1000Base-SX 300m LC DN0982859 11 Checking hardware Commissioning mcBSC Table 2 SFP types used in mcBSC (Cont.) SFP Type Signal Range Connector SFPSM-A Single-mode 1000Base-LX 10km LC SFPCS Copper 10/100/1000Base-T with signal autonegation 100m RJ-45 For information on cabling configuration, see Multicontroller Site IP Connectivity Guidelines. 4 Check the HiGig cabling. Compare the HiGig cabling to the Multicontroller Site IP Connectivity Guidelines, Creating and managing mcBSC hardware documents to make sure that: • • • 5 The cables are connected to the right position. The connections are made properly. The cables are installed and locked correctly. Check the Synchronization cabling. Compare the Synchronization cabling in Creating and managing mcBSC hardware document to make sure that: • • • • 12 The cables are connected to the right position. The connections are made properly. The cables are installed and locked correctly. The cables are of the right type. DN0982859 Issue: 01G Commissioning mcBSC Hardware Check Hardware Check Steps 1 Carry out a visual inspection of the add-in-cards, memories, AMC- and HDD -units. 2 Check add-in cards positions in BCN boxes. Check that Add-in cards are installed according to mcBSC configuration. Table 3 Slot mcBSC Basic module 1 Basic module 2 TRX extension module PS data extension module 1 BJC-A BJC-A BJC-A BOC-A 2 BJC-A BJC-A BJC-A BOC-A 3 BJC-A BJC-A BOC-A BOC-A 4 BOC-A BOC-A BOC-A BOC-A 5 BOC-A BOC-A BOC-A BOC-A 6 BOC-A BOC-A BOC-A BOC-A 7 BOC-A BOC-A BOC-A BOC-A 8 BJC-A BOC-A BOC-A BOC-A AMC 1 HDSAM-A HDSAM-A Empty Empty AMC 2 BSAC-A* BSAC-A* Empty Empty Table 4 Slot 1 Issue: 01G Add in card locations in different BCN-A modules. Add in card locations in different BCN-B modules. mcBSC Basic module 1 Basic module 2 TRX extension module PS data extension module BJC-A BJC-A BJC-A BMPP2-B DN0982859 13 Hardware Check Commissioning mcBSC Table 4 Slot g Add in card locations in different BCN-B modules. (Cont.) mcBSC Basic module 1 Basic module 2 TRX extension module PS data extension module 2 BJC-A BJC-A BJC-A BMPP2-B 3 BJC-A BJC-A BMPP2-B BMPP2-B 4 BMPP2-B BMPP2-B BMPP2-B BMPP2-B 5 BMPP2-B BMPP2-B BMPP2-B BMPP2-B 6 BMPP2-B BMPP2-B BMPP2-B BMPP2-B 7 BMPP2-B BMPP2-B BMPP2-B BMPP2-B 8 BJC-A BMPP2-B BMPP2-B BMPP2-B AMC 1 HDSAM-A HDSAM-A Empty Empty AMC 2 BSAC-A* BSAC-A* Empty Empty BSAC-A is optional. 3 Check CWSAS008 cable. Check that CWSAS008 cable which cross-connecting SAS (serial attached SCSI) and hard disks between BOX1 and BOX2 is connected to SAS connector front of BCN box panel to make sure that: • • • • 4 Check the interchangeability codes. • 5 Compare the interchangeability and versions of the BCN-x, BAFE-x/ BDFE-x for the delivery-specific picking list Check the settings of the DIP switches. • 14 The cable is connected to the right position. The connections are made properly. The cable are installed and locked correctly. The cable are of the right type. Check in BJC-A cards and confirm that SW3 dip switch number 1 to ON (up). From BJC-A board find text “SW3” and check that left switch is ON (Up). Right one is turned to OFF (down). DN0982859 Issue: 01G Commissioning mcBSC Hardware Check For more details on BJC-A DIP switches refer BCN Hardware Jumper Settings and DIMM Configurations document. 6 Check power supply. General requirements for the mcBSC DC power supply. The supply voltage must meet the following requirements: Table 5 Nominal Requirements for the power entry DC Interface A (PSU) Minimum -48/-60 VDC -40.0 V Maximum -72.0 V General requirements for the AC power supply The supply voltage must meet the following requirements at the PSU power inlet: • • • • Nominal voltage of 230 VAC Voltage range between 180 and 264 VAC Frequency between 47 and 63 Hz Maximum voltage interruptions of 20 ms (equal to one cycle missing with 50 Hz frequency) For more information on voltage requirements see Installation Site Requirements for BCN Hardware. Issue: 01G DN0982859 15 Initial inspections Commissioning mcBSC 3 Initial inspections The purpose of initial inspections is to ensure that the mcBSC is ready for the commissioning. Perform the inspection in the order given in this document. 3.1 Visual Inspection Carry out a visual inspection of the BCN-x, BAFE-x / BDFE-x, BAFU-x, BMFU-x and BAFI-x. 3.1.1 Verify LMP MAC address. Figure 1 g MAC Address on BCN box sticker. Write the address down as it will be needed later. 3.2 Checking the settings and configuration 3.2.1 Connection to BCN LMP There is two ways to take connection to LMP (Local Management Processor) of BCN. • • 16 Serial interface via serial port (A) IP management interface via MGT port (B) DN0982859 Issue: 01G Commissioning mcBSC Figure 2 3.2.1.1 Initial inspections LMP connection of BCN-A. Connection to the serial port PC terminal program settings. Table 6 Terminal settings. Baud rate 115200 Data bits 8 Stop bits 1 Parity None Page length 23 Line length 80 Serial port connector Table 7 Issue: 01G Pin order of the RJ-45 serial port connector. Pin Signal Description 1 RTS Request to send 2 NC Not connected 3 TXD Transmit data 4 GND Ground 5 GND Ground 6 RXD Receive data DN0982859 17 Initial inspections Commissioning mcBSC Table 7 3.2.1.2 3.2.1.3 Pin order of the RJ-45 serial port connector. (Cont.) Pin Signal Description 7 NC Not connected 8 CTS Clear to send Steps 1 Open terminal window on the PC and open terminal program. 2 Connect the serial cable between the PC and BCN box. 3 Open LMP session in terminal with Table 6: Terminal settings. settings. Connection to MGT port Default factory IP address values for MGT port: Table 8 3.2.1.4 MGT connection IP addresses BOX id IP address Netmask Gateway 1 192.168.0.10 255.255.255.0 192.168.0.1 2 192.168.0.11 255.255.255.0 192.168.0.1 3 192.168.0.12 255.255.255.0 192.168.0.1 4 192.168.0.13 255.255.255.0 192.168.0.1 5 192.168.0.14 255.255.255.0 192.168.0.1 6 192.168.0.15 255.255.255.0 192.168.0.1 7 192.168.0.16 255.255.255.0 192.168.0.1 8 192.168.0.17 255.255.255.0 192.168.0.1 Steps 1 Configure Windows PC Protocol (TCP/IP) Properties settings. IP address: 192.168.0.5 18 DN0982859 Issue: 01G Commissioning mcBSC Initial inspections Subnetmask: 255.255.255.0 Default gateway: 192.168.0.1 2 Open terminal program. 3 Configure terminal program telnet settings. 4 Connect Ethernet (cat 5) cable between the PC and BCN BOX 1. 3.2.2 Checking the MAC Address of the BCN 3.2.2.1 The mac address of the unit can be found on a sticker contained inside the BCN box at the front see (see Figure 1: MAC Address on BCN box sticker.). Check BCN box MAC address and compare it for MAC address taken in the below step. root@BCNMB-A:~# mch_cli GetMacAddress 00:D0:C9: BA: BB: 22 Both MAC address needs to be the same. Set the MAC address as it is on BCN box sticker. If they are not the same set the MAC address as same as on BCN Box sticker using the below command. root@BCNMB-A:~# mch_cli SetMacAddress xx:xx:xx:xx:xx:xx 3.2.3 Power on for BCN BOXes 3.2.3.1 Steps 1 Create serial connection for BOX 1. 2 Power on BOX 1. 3 Check if LED’s in the front panel are working in the following way. P0 First Red and then Green NS OFF all the time A1 and A2 First Blue and then Green P1 – P8 First Blue and then Red after a while (non equipped octeon slots are OFF) For more information, see Initial inspections. Issue: 01G DN0982859 19 Initial inspections Commissioning mcBSC 4 Monitor BOX 1 start up. 5 Login to LMP. login: root password: root 3.2.4 Checking BCN BOX configuration 3.2.4.1 Steps 1 Check the software information. root@BCNMB-A:~# sw_fw_versioninfo 2 Check the date and time. root@BCNMB-A:~# date Set date and local time with the below command, if required: root@BCNMB-A# date MMDDhhmmYYYY.ss Example root@BCNMB-A:~# date 030411572010.00 Current time set as below 2010/03/04 11:57:00 Set the hardware clock to the current system time: root@BCNMB-A:~# hwclock --systohc Check the hardware clock: root@BCNMB-A:~# hwclock 3 Check node number and rack number. root@BCNMB-A:~# mch_cli GetNodeNumber 1 root@BCNMB-A:~# mch_cli GetRackNumber 65 If needed set the node (box) and rack number according to the BCN box label to the FRU data: Set the node (box) number according to BCN box label. root@BCNMB-A:~# mch_cli SetNodeNumber x g Node number depends on the box (x = number of the box). Set the rack number according to BCN box label. root@BCNMB-A:~# mch_cli SetRackNumber 65 g 20 The default value (factory setting) of rack number is always 65. The value used as rack number is the ASCII value of the cabinet id, that is 65=A. DN0982859 Issue: 01G Commissioning mcBSC Initial inspections 3.2.5 Checking the location of OMU OMU is located in slot 8 of BOX 1. 1 Check the OMU location. Use the following commands: root@BCNMB-A:~# mch_cli GetFRUPCIeRC 8 root@BCNMB-A:~# mch_cli GetPCIeRC 8 Location must be 8. If not, set the location as follows: 2 Set the location of OMU. Use the following commands: root@BCNMB-A:~# mch_cli SetFRUPCIeRC slot8 root@BCNMB-A:~# mch_cli SetPCIeRC 8 In all other BCN boxes, the root complex is set to LMP. root@BCNMB-A:~# mch_cli GetFRUPCIeRC LMP root@BCNMB-A:~# mch_cli GetPCIeRC 0 Check location, it must be 8. If not, change settings as follows: 3 Change settings if needed. Use the following commands: root@BCNMB-A:~# mch_cli SetFRUPCIeRC LMP root@BCNMB-A:~# mch_cli SetPCIeRC 0 3.2.6 Checking PCIe switch configuration Check the PCIe switch speed using the following command: root@BCNMB-A:~# mch_cli GetPCIeSwitchConfig 1 0x78 Value: 0x00410000 The value 0x00410000 means 2.5 Gb/s. Fifth digit from right must be 1. 3.2.6.1 Steps 1 Configure PCIe switch if needed. root@BCNMB-A:~# mch_cli SetPCIeSwitchConfig 1 0x98 1 done! 2 Checking comment for /mnt/fastpath2/module/post.soc. root@BCNMB-A:~# cat /mnt/fastpath2/module/post.soc #TRUNK add id=0 pbmp=0x3000000 Add comment to following line from /mnt/fastpath2/module/post.soc if needed: Issue: 01G DN0982859 21 Initial inspections Commissioning mcBSC root@BCNMB-A:~# vi /mnt/fastpath2/module/post.soc echo “/mnt/fastpath2/module/post.soc” linkscan interval=100000 #TRUNK add id=0 pbmp=0x3000000 Check modification: root@BCNMB-A:~# cat /mnt/fastpath2/module/post.soc #TRUNK add id=0 pbmp=0x3000000 3.2.7 Checking the delivery specific Network Element number Delivery specific NE-number can be found from sticker in BCN box front panel. 3.2.7.1 Steps 1 Check the delivery specific NE-number. root@BCNMB-A:~# mch_cli GetNetworkElementId id: 00000123456 2 network element Set the delivery specific NE-number to the FRU data if needed. root@BCNMB-A:~# mch_cli SetNetworkElementId 00000123456 successful! g NEID is 11 digits long. Add zeros in the beginning, so that you get 11 digit ID. 3.2.8 Checking FRU data of equipped units 3.2.8.1 Command for checking the BCN Mother Board FRU data: root@BCNMB-A:~# mch_cli FRU info 0x20 FRU Name: 1.3 Address: 0x20 ================================================== [Product Info] Format Version = 1 Language Code = en Manufacturer = ADVANTECH Product Name = BMFU-A Part/Model Number = C111728.A1A Product Version = A1-03 Serial Number = 83122400160 Asset Tag = FRU File ID = Check all other cards according the following table. Part/Serial Number must be present. 22 DN0982859 Issue: 01G Commissioning mcBSC Initial inspections Table 9 Equipped units adresses Unit: address: BCN mainboard (LMP) 0x20 Add-in-card 1 0x72 Add-in-card 2 0x74 Add-in-card 3 0x76 Add-in-card 4 0x78 Add-in-card 5 0x7A Add-in-card 6 0x7C Add-in-card 7 0x7E Add-in-card 8 0x80 AMC1 0x82 AMC2 0x84 Check the FRU data of equipped units and compare Serial numbers and Versions to the ones in BCN barcodes.xls 3.2.9 Checking the sensors Print out the sensor data and check that all specified readings (Volts, Amps, etc.) are OK (state=OK). root@BCNMB-A:~# ipmitool sensor 3.2.10 Checking Eth (ethernet) settings of BCN boxes 3.2.10.1 Steps 1 Find the default eth0 settings for the BCN boxes. root@BCNMB-A:~# cat /etc/sysconfig/network-scripts/ifcfg-eth0 DEVICE=eth0 BOOTPROTO=static BROADCAST=192.168.0.255 IPADDR=192.168.0.10 NETMASK=255.255.255.0 ONBOOT=yes Issue: 01G DN0982859 23 Initial inspections Commissioning mcBSC 2 Change the eth0 configuration according to your network plan. root@BCNMB-A:~# vi /etc/sysconfig/network-scripts/ifcfg-eth0 g For box1 IPADDR=192.168.0.10 and for box2 IPADDR=192.168.0.11 etc.) 3 Check network for each box’s. In case of BCN-A: root@BCNMB-A:~# cat /etc/sysconfig/network NETWORKING=yes HOSTNAME=BCNMB-A FORWARD_IPV4=false #GATEWAY="10.10.10.1" NOZEROCONF=yes PEERNTP=no root@BCNMB-A:~# in case of BCN-B: root@BCNMB-B:~# cat /etc/sysconfig/network NETWORKING=yes HOSTNAME=BCNMB-B FORWARD_IPV4=false #GATEWAY="10.10.10.1" NOZEROCONF=yes PEERNTP=no root@BCNMB-B:~# 4 Change the network information of Boxes according to your network plan. root@BCNMB-A:~# vi /etc/sysconfig/network 5 Check eth0.800 for Boxes. root@BCNMB-A:~# cat /etc/sysconfig/network-scripts/ifcfgeth0.800 DEVICE=eth0.800 VLAN=yes BOOTPROTO=static ONBOOT=yes PERSISTENT_DHCLIENT=Y DHCLIENTARGS="-nw" BROADCAST=10.10.10.255 IPADDR=10.10.10.10 NETMASK=255.255.255.0 24 DN0982859 Issue: 01G Commissioning mcBSC g Initial inspections Please note the eth0.800 IP address for different boxes: 10.10.10.11 for box2 10.10.10.12 for box3 10.10.10.13 for box4 10.10.10.14 for box5 10.10.10.15 for box6 10.10.10.16 for box7 10.10.10.17 for box8 6 Change the eth0.800 information of Boxes if needed. root@BCNMB-A:~# vi /etc/sysconfig/network-scripts/ifcfgeth0.800 7 Check IPMI LAN configuration. root@BCNMB-A:~# cat /etc/ipmi/ipmi_lan.conf #addr 10.10.10.10 623 priv_limit admin allowed_auths_callback none md5 allowed_auths_user none md5 allowed_auths_operator none md5 allowed_auths_admin none md5 user 2 on "admin" "admin" admin 5 none md5 # destination <number> <ack|noack> <type> <timeout> <retry> <ip> destination 1 noack 0 10 3 10.10.10.2 8 Change IPMI LAN configuration. root@BCNMB-A:~# vi /etc/ipmi/ipmi_lan.conf 3.2.11 Checking bootscript and card_config for add-in cards cat /etc/ipmi/mch.conf Check the content of the mch.conf file using the following command: root@BCNMB-A:~# cat /etc/ipmi/mch.conf The correct content is described in Creating and managing mcBSC HW under Updating module configuration. Check especially the following: Boot sequence for box1where OMU is located. boot_order=8 1 2 3 4 5 6 7 Boot sequence for all other boxes. boot_order=1 2 3 4 5 6 7 8 For BJC-A in each BOX: Issue: 01G DN0982859 25 Initial inspections Commissioning mcBSC bootscript=99 card_conf=0x08 … For OMU (in BOX 1 slot 8): bootscript=99 card_conf=0x88 … For BOC-A in each BOX: bootscript=17 card_conf=0x18 … For BMPP2-B in each BOX: bootscript=17 card_conf=0x18 0x00 0x43 0x0d 0xc0 0x12 0x0a … Check that the runtime configuration matches above with the following command: mch_cli GetCardConfig cpu<index> where <index> is the add-in card slot number. root@BCNMB-A:~# mch_cli GetCardConfig cpu8 PCI host mode: EP PCI boot: no Failsafe: no clock source: external Octeon speed: Unknown Boot flash: 0 Buffer dir: 0 other config:43 0d c0 12 0a 00 00 00 00 00 00 00 00 00 00 00 00 00 00 hwargs: 0x18 0x00 0x43 0x0d 0xc0 0x12 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 3.2.12 Activate the changes and take the new configuration into use 3.2.12.1 Once the bootscript and card_config changes are done, restart the network and mch services in order to incorporate the changes. root@BCNMB-A:~# service network restart root@BCNMB-A:~# service mch restart Verifying HiGig configuration 26 DN0982859 Issue: 01G Commissioning mcBSC Initial inspections Steps 1 Check the switch configuration. cd /mnt/fastpath; 2 List the configuration. ls -l; ---------- 1 root root 49 May 30 11:03 boot.dim -rwxr--r-- 1 root root 357 May 2 07:32 config.bcm -rw-r--r-- 1 root root 316 May 24 18:39 fastpath.cfg -rwxr--r-- 1 root root 1976 May 2 07:32 init-factory.scrroot@BCNMBA:/opt/cluster# more m10/init.soc-rwxr--r-- 1 root root 1423 May 2 07:32 init.txt -rw-r--r-- 1 root root 16380 May 30 11:03 log2.bin lrwxrwxrwx 1 root root 16 May 24 09:56 module -> /opt/cluster/m10 drwxr-xr-x 2 root root 0 May 2 07:32 module.bku -rw-r--r-- 1 root root 6 May 30 11:03 serial_speed.pending -rw-r--r-- 1 root root 1637 May 30 11:01 startup-config -rwxr--r-- 1 root root 444 May 2 07:32 startup-config-factory -rw-r--r-- 1 root root 1637 May 30 11:01 startup-config-tmp Where m10 indicates first mcBSC module and likewise. Table 10 g Box mcBSC module mapping. Box mcBSC module Box 1 m10 Box 2 m20 Box 3 m30 Box 4 m40 Box 5 m50 Box 6 m60 Box 7 m70 Box 8 m80 If the HiGig configuration for the first module is correct, it is indicated as below and likewise for all the modules: module -> /opt/cluster/m10 3 Check the version of the HiGig files in /opt/cluster/. Example: Issue: 01G DN0982859 27 Initial inspections Commissioning mcBSC In case of BCN-A: root@BCNMB-A:/opt/cluster# more m10/init.soc echo echo init mesh6 ver 0.3.1, module 10 0:port 0x1fffffff en=f 0:local module 10 0:mod port 0 29 my_modid=@module 0:mod modport_map 0x0 7424 higig_port_bitmap=0x00000000 0:mod src_modid_block 0x1500 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1600 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1700 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1800 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x0100 256 port_block_mask_bitmap=0x1fffffff root@BCNMB-A:/opt/cluster# In case of BCN-B: root@BCNMB-B:/opt/cluster# more m10/init.soc echo echo init mesh8 ver 1.4.0, module 10 0:port 0x1fffffff en=f 0:local module 10 0:mod port 0 29 my_modid=@module 0:modreg ing_egrmskbmap.20 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.21 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.22 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.23 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.24 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.1 bitmap=0x1fffffff 0:modreg ing_egrmskbmap.2 bitmap=0x1fffffff root@BCNMB-B:/opt/cluster# g The version number can differ. 3.2.13 Checking the BCN switch configuration 3.2.13.1 Check main switch configuration: 1 Log into the switch. Log into the main switch root@BCNMB-A:~# screen –r Login : admin Password <enter> Press CTRL + 0 to ensure that you are logged to main switch. Login as admin with empty password. MainSwitch >ena Password <enter> 2 Display the port status of switch. MainSwitch # show port all 3 Display the configuration of the switch. MainSwitch # show running-config 28 DN0982859 Issue: 01G Commissioning mcBSC Initial inspections The output displays the configurations of the main switch. • • • • • • VLAN configuration General configurations Loop prevention between ports AMC interfaces Interfaces between Extension and Main switches Logical LAG-interfaces Refer Appendix for default factory switch configurations. 3.2.13.2 Check extension switch configuration from BOX1 and BOX2: 1 Log into the switch. root@BCNMB-A:~# screen –r Press ctrl+g 1 to go to the extension switch: Login : admin Password <enter> ExtensionSwitch>ena Password <enter> 2 Display the port status of switch. ExtensionSwitch # show port all 3 Display the configuration of the switch. ExtensionSwitch# show running-config • • • • • • VLAN configuration General configurations Loop prevention between ports AMC interfaces Interfaces between Extension and Main switches Logical LAG-interfaces Refer Appendix for switch configuration. 4 Exit from the extension switch. To exit from the extension switch and get back to Main switch press ctrl+g 0 To exit from the main switch and get back to LMP press ctrl+g d Refer Appendix for default factory switch configuration details. For more information, see Multicontroller Site IP Connectivity Guidelines and BSC Site IP Configuration Principles documents. g Issue: 01G For Every BCN BOXes in mcBSC repeat all the steps from Power on for BCN BOXes to Checking the BCN switch configuration. DN0982859 29 Initial inspections Commissioning mcBSC 5 After all BCN boxes in the mcBSC are checked, connect to each box LMP one by one and give below commands on each box. ping –c 1 10.10.10.10 ping –c 1 10.10.10.11 ping –c 1 10.10.10.12 ping –c 1 10.10.10.13 ping –c 1 10.10.10.14 ping –c 1 10.10.10.15 ping –c 1 10.10.10.16 ping –c 1 10.10.10.17 ping –c 1 10.10.10.18 3.2.14 Change the flash bank 1 to active 1 Verify active flash bank. root@BCNMB-A:~# mch_cli GetBootFlashBank 0x20 2 Reboot the BCN box in question. root@BCNMB-A:~# reboot During rebooting a message appears: Hit key 'u' to stop autoboot: 3 You have three seconds to press the U letter on the keyboard to open UBOOT session. The following prompt appears on the screen: BCNMB-A# 3 Change the flash bank 1 to active. BCNMB-A# ipmi raw 2e 04 2a 6f 00 00 00 80 00 00 4 Reset the BCN box. BCNMB-A# reset 5 After the BCN box is recovered check the active flash bank. root@BCNMB-A:~# mch_cli GetBootFlashBank 0x20 The flash bank should be 1. 6 g 30 Repeat checking steps for flash bank 1. For Every BCN BOXes in mcBSC repeat all the steps from Power on for BCN BOXes to Checking the BCN switch configuration. DN0982859 Issue: 01G Commissioning mcBSC 7 g g Issue: 01G Initial inspections After the flash bank 1 checking is done, a power reset to the box is needed to get flashbank 0 active. Normal reset is not enough. For Every BCN BOXes in mcBSC repeat all the steps from Power on for BCN BOXes to Checking the BCN switch configuration. DN0982859 31 Commissioning BSAC-A Commissioning mcBSC 4 Commissioning BSAC-A A BSAC-A is an optional unit in case of the Timing over Packet (IEEE1588v2) synchronization feature is in use. The BSAC-A is located in an Advanced Mezzanine Card 2 (AMC 2) bay on the BCN BOX 1 and 2 in mcBSC. If the BSAC-A is not in use, this chapter can be skipped. Before you start 1. Open LMP session via serial or MGT connection for BOX 1. 2. Start log collection on terminal application in use. Steps 1 Ping BSAC-A 1 (located in BOX 1). root@BCNMB-A:~#ping 10.10.10.50 ctrl+c stops pinging Ping BSAC-A 2 (located in BOX 2). root@BCNMB-A:~#ping 10.10.10.50 ctrl+c stops pinging 2 Connect into BSAC-A with SSH. root@BCNMB-A:~# ssh 10.10.10.50 root@10.10.10.50's password: root Sometimes the following error massage may occur: @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @ WARNING: REMOTE HOST IDENTIFICATION HAS CHANGED! @ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ IT IS POSSIBLE THAT SOMEONE IS DOING SOMETHING NASTY! Someone could be eavesdropping on you right now (man-in-the-middle attack)! It is also possible that the RSA host key has just been changed. The fingerprint for the RSA key sent by the remote host is 72:cb:fa:89:e5:91:c3:00:7b:45:3d:7a:cc:6a:76:06. Please contact your system administrator. Add correct host key in /root/.ssh/known_hosts to get rid of this message. Offending key in /root/.ssh/known_hosts:1 RSA host ky for 10.10.10.11 has changed and you have requested strict checking. Host key verification failed. In order to continue run command: root@BCNMB-A:~# rm /root/.ssh/known_hosts 32 DN0982859 Issue: 01G Commissioning mcBSC Commissioning BSAC-A root@BCNMB-A:~# ssh 10.10.10.50 The authenticity of host '10.10.10.50 (10.10.10.50)' can't be established. RSA key fingerprint is 1d:b0:ed:13:2a:db:8c:f4:d5:86:d4:5b:b2:56:d5:7a. Are you sure you want to continue connecting (yes/no)? yes Warning: Permanently added '10.10.10.50' (RSA) to the list of known hosts. root@10.10.10.50's password: root 3 Check time and date. Go to directory: /dev/shm root@BCNSA-A:/root> cd /dev/shm/ root@BCNSA-A:/dev/shm> date Set date and time if needed: root@BCNSA-A:/dev/shm> date 1019112013 * (MMDDHHMMYY * Tue Mar 19 11:20:00 GMT 2013 root@BCNSA-A:/dev/shm> cd 4 Printout versions. root@BCNSA-A:/> cat /mnt/etc/bcnsa-a_version Example: BSAC-A BSAC-A BSAC-A BSAC-A 5 - Hardware Revision: Software Release: FPGA Release: CPLD Release: C112139.B2B (DR3) 02.05.0003 01.07.0000 00.02.0000 Take the following printout logs. root@localhost:/root> root@localhost:/root> root@localhost:/root> root@localhost:/root> eth2.800 root@localhost:/root> root@localhost:/root> root@localhost:/root> cat cat cat cat /etc/sysconfig/network-scripts/ifcfg-eth0 /etc/sysconfig/network-scripts/ifcfg-eth1 /etc/sysconfig/network-scripts/ifcfg-eth2 /etc/sysconfig/network-scripts/ifcfg- ifconfig cat /etc/dhclient-eth2.conf cat /etc/dhclient-eth2.800.conf Exit from SSH session. root@localhost:/root> exit 6 Connect into BSAC-A with telnet. root@BCNMB-A:~# telnet 10.10.10.50 10000 Trying 10.10.10.50... Connected to 10.10.10.50. Escape character is '^]'. Issue: 01G DN0982859 33 Commissioning BSAC-A Commissioning mcBSC Linux 2.6.27.39-grsec (localhost) (00:04 on Thursday, 01 January 1970) Welcome to BCNSA-A AMC Command-Line User: admin Password: <enter> 7 Go to ieee1588v2 directory. (BCNSA-A)>mgmt (BCNSA-A)(mgmt)>sync (BCNSA-A)(mgmt/sync)>ieee1588v2 Take a printout log from synchronization configuration. BCNSA-A)(mgmt/sync/1588v2)>view sync Exit from synchronization menu. BCNSA-A)(mgmt/sync/1588v2)>exit BCNSA-A)(mgmt/sync)>exit BCNSA-A)(mgmt)>exit 8 Take a printout log from eSW version. (BCNSA-A)>version Exit from telnet session. (BCNSA-A)>exit g Re-execute above steps with another flash bank. 9 Check an active flash bank. root@BCNMB-A:~# ipmitool -t 0x84 -b 7 raw 0x2e 0x1b 0x2a 0x6f 0x00 Printout’s last digit indicates an active flash bank. In the following example, the active flash bank is Bank 0: 2a 6f 00 00 Activate another flash bank. Example commands to activate bank 1 are the following: root@BCNMB-A:~# mch_cli Deactivate AMC2 root@BCNMB-A:~# ipmitool -t 0x84 -b 7 raw 0x2e 0x1C 0x2a 0x6f 0x00 0x01 root@BCNMB-A:~# mch_cli Activate AMC2 Check after BSCA-A is recovered that bank 1 is active. root@BCNMB-A:~# ipmitool -t 0x84 -b 7 raw 0x2e 0x1b 0x2a 0x6f 0x00 Activation command for bank 0 is: ipmitool -t 0x84 -b 7 raw 0x2e 0x1C 0x2a 0x6f 0x00 0x00 34 DN0982859 Issue: 01G Commissioning mcBSC Commissioning BSAC-A 10 After the steps 1-8 are executed from both BSAC-A 0 flash banks, open an LMP session in BOX 2, connect to BSAC-A 1 (10.10.10.51), and repeat the steps 1 - 9. Issue: 01G DN0982859 35 Monitoring mcBSC startup Commissioning mcBSC 5 Monitoring mcBSC startup Purpose This section describes the monitoring of system startup and provides information for solving possible disturbances. The startup of the whole system depends on the startup priorities of the system's units. A unit with higher priority is given loading permission before a unit with lower priority. Within the system, the units are started up according to their respective priorities. For example, all the base station controller signalling units (BCXU) are given permission to load simultaneously, as they all have the same priority. In the case of doubled units, the working units are given loading permission before the spare units. The startup order of the system is as follows: 1. Operation and Maintenance Unit (OMU) 2. Marker and Cellular Management Unit (MCMU) 3. Other units (BCXU, PCUM, ETME, ETMA) Monitoring OMU startup Purpose Monitor the startup of the Operation and Maintenance Unit (OMU). A failure in the OMU startup may lead to a similar failure in all other units. When the startup of the OMU has reached the stage where the service terminal software is started up, the Recovery Service Terminal (RCBUGG) extension is taken into use. RCBUGG is an extension of the service terminal software which enables the monitoring of unit states. It is started up with a service terminal software command. The RCBUGG contains commands that correspond with those of the Working State and Restart Handling MML (command group US). Even if the startup of the MMI system fails, the working states of the units can be controlled with the RCBUGG extension. A prerequisite for the successful running of the RCBUGG is that the recovery system itself has been started up. For information on how to use the service terminal, see the following command references in NSN Product Information Center: • • Service terminal under Reference/Commands/Service terminal commands in the PDF view. RCBUGG under Reference/Commands/Service terminal commands in the PDF view. Before you start Check that the working state of the OMU is WO-EX during the startup of the system. If the state of OMU is TE or SE, the maintenance programs will be started up in the Marker and Cellular Management Unit (MCMU) and the startup is monitored in the MCMU. 1. Open LMP session via serial or MGT connection for BOX 1. 36 DN0982859 Issue: 01G Commissioning mcBSC Monitoring mcBSC startup 2. Start log collection on terminal application in use. Steps 1 Connect the service terminal. Connect to OMU via minicom. root@BCNMB-A: minicom cpu8 2 Monitor the computer unit state. Monitor the states of units with the RCBUGG extension. a) Take the RCBUGG into use: ZLE:U,RCBUGGGX; b) Monitor the states of the computer units: ZUSIC:COMP; c) Stop monitoring: CTRL + C 3 Reset the unit. Reset the unit by using the following command: ZAUL; 4 Monitor the startup of the OMU. a) The first phase output indicates the startup of the boot loader program block (BOLERO): DMX SYSTEM STARTUP TESTS b) Scanning PCI bridges: SCANNING PCI BRIDGES c) Configuring PCI bridges: CONFIGURING PCI/PCI BRIDGES d) Scanning PCI devices: SCANNING PCI DEVICES e) Flash version of CPU is shown: BOPBJCGX.PAC <ver> f) Choosing software package in the OMU successful: CHOOSING PACKET g) Loading of the computer configuration table successful: LOADING NET CONFIG... h) Loading of the load list successful: LOADING LOAD LIST FROM <source> i) Loading of the load modules successful: MODULE LOADING STARTS LOADING MODULES FROM <source> ALL MODULES LOADED j) Debugger software started up: DEBUGGER READY Issue: 01G DN0982859 37 Monitoring mcBSC startup Commissioning mcBSC k) First 'PROCESSING FAMILIES' notice is output on the terminal: PROCESSING FAMILIES l) The FISLIB Library Manager (FIZSLM) is started up: PROCESSING FAMILIES FIZ ... m) Loading of the first load group: LOADING STARTED 0003.. n) Initialization of work files: INITIALIZING WORK FILES o) The FUNLIB Library Manager (FUZNLM) startup: PROCESSING FAMILIES FUZ ... p) The unit state administration program block (USAPRO) is given permission to load: READY - PHASE 2 FILE LOADING ACTIVATED q) Loading of a load group OK. All remaining load groups are loaded: LOADING STARTED ... r) The USAPRO is given permission to start the program blocks: READY - PHASE 3 s) Startup of program blocks: PROCESSING FAMILIES... t) Running SW package information: RUNNING PACKAGE u) Startup of unit is terminated: READY - WO 5 Go back to LMP session. CRTL + a q <enter> Monitoring MCMU startup Before you start Check that the working state of the MCMU is WO-EX or SP-EX during the startup of the system. 1. Open LMP session via serial or MGT connection for BOX 1. 2. Start log collection on terminal application in use. Steps 1 Connect the service terminal. Connect to MCMU 1 via minicom. root@BCNMB-A: minicom cpu1 2 Monitor the computer unit state. Monitor the states of units with the RCBUGG extension. 38 DN0982859 Issue: 01G Commissioning mcBSC Monitoring mcBSC startup a) Take the RCBUGG into use: ZLE:U,RCBUGGGX; b) Monitor the states of the computer units: ZUSIC:COMP; c) Stop monitoring: CTRL + C 3 Reset the unit. Reset the unit by using the following command: ZAUL; 4 Monitor the startup of the MCMU. a) The first phase output indicates the startup of the BOLERO: DMX SYSTEM STARTUP TESTS b) Scanning PCI bridges: SCANNING PCI BRIDGES c) Configuring PCI bridges: CONFIGURING PCI/PCI BRIDGES d) Scanning PCI devices: SCANNING PCI DEVICES e) Flash version of CPU is shown: BOPBJCGX.PAC <ver> f) Loading of the computer configuration table successful: LOADING NET CONFIG... g) Loading of the load list successful: LOADING LOAD LIST FROM <source> h) Loading of the load modules successful: MODULE LOADING STARTS LOADING MODULES FROM <source> ALL MODULES LOADED i) Debugger software started up: DEBUGGER READY j) The FIZSLM is started up: PROCESSING FAMILIES FIZ ... k) Initialization of work files: INITIALIZING WORK FILES l) Loading of first loading group: LOADING STARTED 0002... m) The FUZNLM startup: PROCESSING FAMILIES FUZ ... n) The USAPRO is given permission to load: READY - PHASE 2 FILE LOADING ACTIVATED o) Loading of a load group OK. All remaining load groups are loaded: LOADING STARTED ... p) Startup of program blocks: PROCESSING FAMILIES... Issue: 01G DN0982859 39 Monitoring mcBSC startup Commissioning mcBSC q) The USAPRO is given permission to start up program blocks: READY - PHASE 3 r) Startup of program blocks: PROCESSING FAMILIES... All remaining program blocks are created and started up. s) Running SW package information: RUNNING PACKAGE t) Startup of unit is terminated: READY - WO or READY - SP Repeat the startup monitoring with the MCMU 1 in BOX 2. 5 Go back to LMP session. CRTL + a x <enter> Monitoring BCXU startup Before you start Check that the working state of the BCXU is WO-EX during the startup of the system. 1. Open LMP session via serial or MGT connection for BOX 1. 2. Start log collection on terminal application in use. Steps 1 Connect the service terminal. Connect to BCXU 0 via minicom. root@BCNMB-A: minicom cpu2 2 Monitor the computer unit state. Monitor the states of units with the RCBUGG extension. a) Take the RCBUGG into use: ZLE:U,RCBUGGGX; b) Monitor the states of the computer units: ZUSIC:COMP; c) Stop monitoring: CTRL + C 3 Reset the unit. Reset the unit by using the following command: ZAUL; 40 DN0982859 Issue: 01G Commissioning mcBSC 4 Monitoring mcBSC startup Monitor the startup of the BCXU. a) The first phase output indicates the startup of the BOLERO: DMX SYSTEM STARTUP TESTS b) Flash version of CPU is shown: BOPBJCGX.PAC <ver> c) Loading of the computer configuration table successful: LOADING NET CONFIG... d) Loading of the load list successful: LOADING LOAD LIST FROM <source> e) Loading of the load modules successful: MODULE LOADING STARTS LOADING MODULES FROM <source> ALL MODULES LOADED f) Debugger software started up: DEBUGGER READY g) The FIZSLM is started up: PROCESSING FAMILIES FIZ ... h) Initialization of work files: INITIALIZING WORK FILES i) The USAPRO is given permission to load: READY - PHASE 2 FILE LOADING ACTIVATED j) The FUZNLM startup: PROCESSING FAMILIES FUZ ... k) Loading of first loading group: LOADING STARTED 0008... l) Startup of program blocks: PROCESSING FAMILIES... m) Loading of a loading group: LOADING STARTED... All remaining loading groups are loaded. n) The USAPRO is given permission to start up program blocks: READY - PHASE 3 o) Startup of program blocks: PROCESSING FAMILIES... All remaining program blocks are created and started. p) Running SW package information: RUNNING PACKAGE q) Startup of unit is terminated: READY - WO Repeat the steps with BCXU 2. Repeat the steps with rest of BCXUs in BOXes those are located. Monitoring PCUM startup Before you start Check that the working state of the PCUM is WO-EX during the startup of the system. Issue: 01G DN0982859 41 Monitoring mcBSC startup Commissioning mcBSC 1. Open LMP session via serial or MGT connection for BOX 1. 2. Start log collection on terminal application in use. Steps 1 Enter into mch_cli and reset the unit. Enter into mch_cli. Reset the unit by using the following commands: Deactivate CPU<ind>; After the LED state changes from red to blue, give the following command: Activate CPU<ind>; 2 Connect the service terminal. Connect to OMU via minicom. root@BCNMB-A: minicom cpu8 3 Monitor the startup of the PCUM. a) Displays the ports in each interface: Interface... b) The image file is loaded from BCXU to PCUM via TFTP: TFTP from server ... All image files are loaded. c) Allocates memory for ELF segment: Attempting to allocate memory... d) Loading Linux kernel: Loading Linux kernel with entry point... e) Initializing c groups: Initializing cgroup... f) Registering transport modules: RPC: Registered udp... g) Registering I/O schedulers: io scheduler... h) Registering ethernet interface with probe framework: KERNEL LOG: ETH... i) Setting bootbus flash: Bootbus flash: Setting... for BMPP-B: physmap platform flash device: 08000000 at... j) Starting TFTP to get MPCUGBCA.IMG: IFETH0: 10000 Mbps... MPCUGBCA.IMG TFTP complete In case of BMPP2-B the image name is MPCUGBCB.IMG k) Starting TFTP to get QWERTYGX.IMG: QWERTYGX.IMG TFTP complete l) Launching PCU Gb application: Launching PCU Gb Application... 42 DN0982859 Issue: 01G Commissioning mcBSC Monitoring mcBSC startup m) Starting system services and component framework: IMSGW_CM : System... Calling ST Init... n) Starting Stage 0 applications: IMSGW_CM : Component Manager... o) Starting Stage 1 applications: IMSGW_CM : Component Manager... p) Starting Stage 2 applications: IMSGW_CM : Component Manager... q) Startup PCUM: startup_PCUM.log r) Prompts for user name and password to login: Username: Password: Issue: 01G DN0982859 43 Inspecting EMB connections Commissioning mcBSC 6 Inspecting EMB connections The Ethernet Message Bus (EMB) LAN connections are tested by sending a test message from each computer unit to all other units. The purpose of this is to ensure that all the computer units can be reached through both EMB-0 and EMB-1. The tests are executed with the commands of the EBSTER service terminal extension. EBSTER sends the test message through the MB to the post offices of the computer units, and the post offices acknowledge the message through the EMB. The test is run separately for EMB-0 and EMB-1. Table 11 mcBSC Ethernet Message Bus addresses Unit EMB address OMU 0000 MCMU-0 0004 MCMU-1 0005 BCXU-0 0049 BCXU-1 004A BCXU-2 004B BCXU-3 004C BCXU-4 004D BCXU-5 004E BCXU-6 004F BCXU-7 0050 Before you start • • • • 44 Open MML session and check OMU session. Check the states of the LAN ports. ZQHQ:OMU:; Check the states of the computer units. ZUSI:; Check that there are no LAN-related alarms active. ZAHO; DN0982859 Issue: 01G Commissioning mcBSC Inspecting EMB connections Steps 1 Load and start EBSTER. Open a service terminal session to OMU. Load EBSTER: 00-MAN> ZLP:1,EBS; Start EBSTER: 00-MAN> Z1; 2 Test EMB with a test message. Run the test for EMB-0: 00:EBS>AT:0x007F,0 Run the test for EMB-1: 00:EBS>AT:0x007F,1 3 Check that the data in the computer units’ MAC address table is correct. To check the MAC addresses of all computer units, give the following command: 00:EBS>A:0x000:0xFFFF check the following • • • 4 All computer units have been listed. There are two MAC addresses for each computer. Both EMB0 and EMB1 are OK for all units and no units are listed at the end of the execution print-out. Check the error logs. a) To display the EPOFFI internal log using routine call, give the following command: 00:EBS>L Issue: 01G DN0982859 45 Inspecting EMB connections Commissioning mcBSC Example output: EPOFFI’s Internal log counters: Initialization errors: 0 ETHLIB out of resources: 0 Sending errors: 0 Receiving errors: 0 Ethernet link down: 0 Resend requests: 0 TX flow control sends: 0 RX flow control sends: 0 Invalid messages: 0 Invalid frames: 0 Out of memory: 0 Out of buffers: 0 Buffer handling errors: 0 Initialization log: Event type Date and time Description ================================================================== ======= Other event; see log text 11/06/08 19:31:20.27 CPU type EMB compatible Other event; see log text 11/06/08 19:31:20.19 Registrated as post-offic e (EMB_into_use == T) Delivery-hand log: Event type Date and time Description ================================================================== ======= Other event; see log text 11/06/17 07:20:32.24 Non-mir 87386/87387 (0) l ost, LAN-0, 32 Other event; see log text 11/06/08 19:31:23.28 EMB-1 link up, auto1000FD , auto TX/auto RX flowc Other event; see log text 11/06/08 19:31:23.21 EMB-0 link up, auto1000FD , auto TX/auto RX flowc Delivery-hand log: Event type Date and time Description ================================================================== ======= Other event; see log text 11/06/17 13:35:08.51 EMB-1 deseparated Other event; see log text 11/06/17 13:35:08.37 EMB-1 set in TE-state Other event; see log text 11/06/17 13:34:52.72 EMB-1 set in TE-state Other event; see log text 11/06/16 15:34:39.81 Resources released (no re sponse in 46 DN0982859 Issue: 01G Commissioning mcBSC Inspecting EMB connections 30s) from:31 Other event; see log text Main SYM-comp Other event; see log text deseparated Other event; see log text deseparated 11/06/08 19:31:39.96 Unit set as uter 11/06/08 19:31:37.95 EMB-1 11/06/08 19:31:37.95 EMB-0 b) To display EPOFFI initialization and status values, give the following command: 00-EBS>LI; Example output: 2011-06-29 11:22:35.63 epo_init_state:Main SYM-computer found EMB address space: Address space known. Physical address: 00FDH First address: 0000H Last address: First address: 0080H Last address: 007CH 00FDH Inquiry of separation information: Own unit not separated EMB-0: interface not separated, lan exists EMB-1: interface not separated, lan exists 5 Exit and unload EBSTER. To exit the session: Z; To unload EBSTER: ZL:1; Issue: 01G DN0982859 47 Checking the I/O system of mcBSC Commissioning mcBSC 7 Checking the I/O system of mcBSC Purpose This procedure specifies how the I/O system of Flexi BSC should be checked in the commissioning tests and how the functioning of the I/O system and devices is checked. Opening the first MML session in mcBSC Purpose When a system is delivered, the user identifier of the system has been defined as <SYSTEM> and the password as <SYSTEM>. These user identifier and password definitions are of a general nature and they are intended to be used only in factory acceptance testing. The main user of the system or the system administrator makes the actual authority definitions for the terminals and users with MML commands. The procedure for setting up the first session and for defining and testing the user identifier and password is presented here. Examples are also provided. Before you start 1. Open LMP session via serial or MGT connection for BOX 1. 2. Start log collection on terminal application in use. Steps 1 Connect to MML session via VIMMLAGX Service Terminal extension. 0000-MAN> ZLP:1,VIM 0000-MAN>1 0000-VIM>C:0 The following text is displayed on the screen: ENTER USERNAME < Enter the user identifier SYSTEM and press <CR>. The following text is displayed: ENTER PASSWORD < Enter the password SYSTEM and press <CR>. If the setting up of the session is successful, the following message is displayed: WELCOME TO THE DX 200 SERIES DIALOGUE MAIN LEVEL COMMAND <___> < Possible error messages: /*** PASSWORD TOO SHORT ***/ The password is too short. Minimum length is six characters. /*** USER AUTHORISATION FAILURE ***/ 48 DN0982859 Issue: 01G Commissioning mcBSC Checking the I/O system of mcBSC The user identifier entered has not been programmed into the system or the passwordhas been given incorrectly. Enter the password again. Checking the power handling of the mass memory devices Testing the power system of the WDU Steps 1 Check the state of WDU 0 (ISI). ZISI::WDU,0; The WDU state should be WO-BU. 2 Prevent file updates to disk (DUP). ZDUP:OMU:NO,:; 3 Disconnect the power. Pull the switch in HDSAM-A one step out. Within a few seconds the blue hot swap LED should lit solid. Also red out of service LED should lit. 4 Remove the WDU. Now it is safe to pull out the HDSAM-A disk from the AMC adapter. 5 Check the state of the alarm in the WDU (ISI). ZISI::WDU,0; The state of the WDU is TE-ID and the alarm 2692 is set. 6 Reconnect the power. Push the HDSAM-A back into the AMC adapter. Wait until blue hot swap LED is solid. Push the switch in HDSAM-A to bottom. The power is reconnected and green power good LED should lit. The blue and red LED should not lit anymore. 7 Change the state of the WDU (ISC). ZISC::WDU,0:WO-ID; ZISC::WDU,0:WO-BU; 8 Resume file updates to disk (DUR). ZDUR:OMU; Issue: 01G DN0982859 49 Checking the I/O system of mcBSC 9 Commissioning mcBSC Check the state and the alarm of the WDU (ISI). The state of the WDU should be WO-BU and the alarm 2692 should be cancelled. 10 Repeat steps 1 to 9 with WDU 1. Checking the state of the I/O devices Purpose The procedure is used for checking the number and states of the I/O equipment and the output controls (that is, correspondence with the source data). Note that included printouts provide examples only, the actual printouts may differ from the ones presented here. Before you start Check that the correct number of the I/O devices has been packaged for the system. Check their states and state transitions. Steps 1 Display the I/O devices (ISI). Display the I/O devices of all the units of the system. ZISI:; 2 Compare the number of the devices with the source data. 3 Compare the states of the devices with the source data. Expected outcome Example of command output is the following: Example ZISI:; LOADING PROGRAM VERSION 12.5-0 I/O DEVICE WORKING STATE AND SPARE DEVICE SYSTEM = SOLIFER UNIT = OMU DEVICE STATE SPARE DEVICE DEVICE STATE TAPE TYPE WDU-00 WDU-01 VTP-00 VTP-01 VTP-02 50 WO-BU WO-BU BL-SY BL-SY BL-SY - - DN0982859 INFO TAPE STATE - Issue: 01G Commissioning mcBSC Checking the I/O system of mcBSC VTP-03 VTP-04 VTP-05 VTP-06 VTP-07 VTP-08 VTP-09 VTP-10 VTP-11 VTP-12 VTP-13 VTP-14 VTP-15 VTP-16 VTP-17 VTP-18 VTP-19 VTP-20 VTP-21 VTP-22 VTP-23 VTP-24 VTP-25 VTP-26 VTP-27 VTP-28 VTP-29 VTP-30 VTP-31 VTP-32 VTP-33 VTP-34 VTP-35 VTP-36 VTP-37 VTP-38 VTP-39 VTP-40 VTP-41 VTP-42 VTP-43 VTP-44 VTP-45 VTP-46 VTP-47 VTP-48 VTP-49 VTP-50 VTP-51 VTP-52 VTP-53 VTP-54 VTP-55 VTP-56 VTP-57 Issue: 01G BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY WO-BU BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY - - DN0982859 - 51 Checking the I/O system of mcBSC VTP-58 VTP-59 VTP-60 VTP-61 VTP-62 VTP-63 VTP-64 VTP-65 VTP-66 VTP-67 VTP-68 VTP-69 VTP-70 VTP-71 VTP-72 VTP-73 VTP-74 VTP-75 VTP-76 VTP-77 VTP-78 VTP-79 VTP-80 VTP-81 VTP-82 VTP-83 VTP-84 VTP-85 VTP-86 VTP-87 VTP-88 VTP-89 VPP-00 VPP-01 VPP-02 VPP-03 VPP-04 VPP-05 VPP-06 VPP-07 VPP-08 VPP-09 VPP-10 VPP-11 VPP-12 VPP-13 VPP-14 VPP-95 VPP-96 VPP-97 VPP-98 VPP-99 VDS-00 VDS-01 VDS-02 52 Commissioning mcBSC BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY BL-SY WO-BU WO-BU WO-BU - - DN0982859 - Issue: 01G Commissioning mcBSC Checking the I/O system of mcBSC VDS-03 VDS-04 VDS-05 VDS-06 VDS-07 VDS-08 VDS-09 VDS-10 VDS-11 VDS-12 VDS-13 VDS-14 VDS-15 WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU WO-BU - - - COMMAND EXECUTED where: LPT = Line printer VDU = Display unit WDU = Hard disk unit VTP = Virtual Terminal VPP = Virtual Printer Protocol VDS = Virtual Data Storing device The disk drives should enter the state WO-BU and remain in it. The VDU and LPT units are in WO-ID or BL-SY state, depending on whether the terminal equipment is connected or not. The state of the units can be changed with the ISC command. Unxpected outcome If some peripheral devices cannot be brought into the state WO-BU, check the operation and cabling of the peripheral devices. The disk drives have diagnostics of their own. The printers and display units have been tested in connection with preparatory measures. Issue: 01G DN0982859 53 Checking the hardware configuration of mcBSC Commissioning mcBSC 8 Checking the hardware configuration of mcBSC Purpose Following are the commands used to print the hardware configurations: Purpose Steps 1 Print the hardware configuration (WTI). ZWTI:J; ZWTI:C; ZWTI:U; ZWTI:P; Compare the hardware configuration to the Equipment List for Multi Controller BSC in NSN mcBSC Site Documentation. 54 DN0982859 Issue: 01G Commissioning mcBSC Checking the power system and diagnostics of mcBSC 9 Checking the power system and diagnostics of mcBSC Purpose The powersystem is checked to ensure that the supervision, alarm, and recovery functions of the system are working properly. Since the outputs presented here are examples only, the actual outputs may, in some cases, differ from them. Before you start A prerequisite for the checking of the mcBSC maintenance system is that the checks connected with the system start-up have been successfully performed. Testing the recovery from power breaks Purpose The purpose of testing is to test the recovery of the system from different power breaks. The system automatically disables those units which are without power after a power break. The system starts the units in their correct working state after the power is on again. Testing the recovery from a complete power break in the system Steps 1 Open MML session via serial or MGT port. 2 Check that all units are in states WO-EX or SP-EX (USI, ISI). If an unit is not in the appropriate state, change the state with the USC command. ETMEs and ETMAs may be in SE-NH states. Issue: 01G DN0982859 55 Checking the power system and diagnostics of mcBSC Commissioning mcBSC 3 Disconnect power from the system. 4 Connect power to the system. 5 Reopen MML session via serial or MGT port. 6 Wait until OMU starts in state WO-EX. 7 Output the working states of the units from the MML terminal. 8 Monitor the unit states (USI). Check that every unit starts in the state it had before the power break: ZUSI; 9 Monitor the alarm printer. All the starting units should cause a notice (one of the following): 0691 AUTOMATIC RECOVERY ACTION WO-RE TO WO-EX 0691 AUTOMATIC RECOVERY ACTION SP-RE TO SP-UP 0691 AUTOMATIC RECOVERY ACTION SP-UP TO SP-EX 10 Print out the states (USI, USL). Print out the states of all the units and check that they are in the correct working state. Use the following commands to output the working states of the units: ZUSI:ALL; or alternatively ZUSL:,INCO; which outputs all units with incorrect state. 11 Update the date and time (DCS). ZDCS:<date>,<time>:ST=OFF/ON; 12 Check the states of WDU devices (ISI, ISC). ZISI; If the states are not WO, change them: ZISC; 56 DN0982859 Issue: 01G Commissioning mcBSC Checking the power system and diagnostics of mcBSC Testing state transitions and unit diagnostic 1 Open MML session wia serial or MCT connection. 2 Run single unit diagnostics. For diagnostic the unit, change the state to TE-EX with ZUSC command: ZUSC:XXXX,Y:ZZ; where: XXXX=unit Y = index ZZ = state The unit states are: SE-NH - SE-OU - TE-EX - SP-EX - WO-EX -> SE -> TE -> SP ->WO <- SE <- SE <- TE <- SP OMU, MCBC, ETMA and PTUM units don’t have SP-EX state at all. Those must be changed with FCD parameter from WO-EX to TE-EX. g Note that: Only two BCXUs can be on TE-EX state at the same time. Only one MCMU and EMB can be in TE-EX state at the same time. Start diagnostic with command: ZUDU:XXXX,Y; where: XXXX=unit Y = index 3 Check the status of the diagnostic with command: ZUDQ; When diagnostics for all units are completed and all units are changed back to normal working states, check the diagnostic results to the log file using command: ZUDH; ***default is all results from the same day*** Issue: 01G DN0982859 57 Checking the power system and diagnostics of mcBSC Commissioning mcBSC Diagnostics of the WDUs 1 Check the state of the WDU (ISI). 2 Change the state of the WDU to TE-ID (ISC). ZISC::WDU,0:WO-ID; ZISC::WDU,0:TE-ID; 3 Run diagnostics for the WDU (UDD). ZUDD:OMU:WDU,0; The diagnostics reports indicate that the unit is in working order: 3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK 4 Change the WDU to the original state (ISC). ZISC::WDU,0:WO-ID; ZISC::WDU,0:WO-BU; 5 Repeat steps 1 to 4 with the another WDU. Steps 1 Check the state of the WDU (ISI). 2 Change the state of the WDU to TE-ID (ISC). ZISC::WDU,0:WO-ID; ZISC::WDUS,0:TE-ID; 3 Run diagnostics for the WDU (UDD). ZUDD:OMU:WDU,0; The diagnostics reports indicate that the unit is in working order: 3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK 4 Change the WDU to the original state (ISC). ZISC::WDU,0:WO-ID; ZISC::WDU,0:WO-BU; 58 DN0982859 Issue: 01G Commissioning mcBSC 5 Checking the power system and diagnostics of mcBSC Repeat steps 1 to 4 with the another WDU. Testing the spare units Steps 1 Equip the mcBSC with spare plug-in units and perform diagnostics. Follow the instructions in Monitoring mcBSC startup. Issue: 01G 2 Write a problem report if faulty plug-in units are found. 3 Change the faulty plug-in units. DN0982859 59 Verifying the software versions of mcBSC Commissioning mcBSC 10 Verifying the software versions of mcBSC Purpose The purpose of this verification is to check eSW versions and software (SW) versions, to compare them with the Delivery Catalogue and making sure that data in modules is not corrupted. BCN-A is used as an example in this chapter. Purpose Steps 1 Open LMP session via serial or MGT connection to BOX 1. 2 Check the eSW versions from LMP. root@BCNMB-A:~# sw_fw_versioninfo Repeat in every BCN-A Boxes in the mcBSC. Compare the eSW versions to the version list in Pre-Processor Program Information in the BSC Base Station Controller Release Documentation. 3 Start MML session via serial or MGT connection. 4 Check the eSW version with MML. Use ZWD MML commands to check the eSWs in the flash memory. ZWDI; ZWDT:UT=MCBC,; ZWDT:UT=MCBC,SW=KERNEL; ZWDT:UT=MCBC,SW=ROOTFS; ZWDT:UT=MCBC,SW=VCMC; ZWDP:UT=MCBC; ZWDP:PT=BJC_A,; ZWDI:PT=BJC_A,SW=BIOS; ZWDI:PT=BJC_A,SW=BACKUPBIOS; ZWDD:PT=BJC_A; ZWDI:PT=BJC_A,SW=FPGA:; ZWDD:UT=PCUM; ZWDT:UT=PCUM,SW=UBOOT; ZWDP:UT=PCUM; ZWDD:UT=ETME; ZWDT:UT=ETME,SW=UBOOT; ZWDP:UT=ETME; ZWDD:UT=ETMA; 60 DN0982859 Issue: 01G Commissioning mcBSC Verifying the software versions of mcBSC ZWDT:UT=ETMA,SW=UBOOT; ZWDP:UT=ETMA; ZWDP:UT=PTUM; ZWDD:UT=PTUM; ZWDT:UT=PTUM,UI=1,SW=UCSW; Compare the eSW versions to the version list in Pre-Processor Program Information in the BSC Base Station Controller Release Documentation. 5 Print out all SW packages (WQO). Print out all SW packages installed on disks. ZWQO; and ZWQO:CR; 6 Perform a verification (WQB). Perform a verification for each SW package. The display prints out during the execution of the command: ZWQB:STAT=<running_packet_status>; 7 Check if any faults have been detected. Compare the printout with the Delivery Catalogue. Expected outcome The SW verification should be faultless and the versions should be the same as those listed in the Delivery Catalogue. Unxpected outcome If any faulty modules are found, replace them with new ones. Issue: 01G DN0982859 61 Copying additional software and setting the time zone in mcBSC Commissioning mcBSC 11 Copying additional software and setting the time zone in mcBSC Steps 1 Create a temporary Telnet connection to the mcBSC. Create a temporary Telnet connection, see the BSS Integration manual. 2 Copy the customer specific files (IWY, IBC). Copy the customer specific files (PRFILE, FIFILE) to run a package LFILES directory via Telnet. 3 Install the Change Deliveries. Check that the general Change Deliveries (CD) are installed. Check the CD level of the software build (WNH) and install the CDs that have not been installed. See further instructions in the CD document. 4 Set the time zone (DCE). ZDCE:<direction>:<difference>; Example Setting the time zone for GMT +1h ZDCE:PLUS:01-00; In the next phase, the mcBSC is restarted. After that, the time zone setting is in use. The time zone information is stored in a Flexi BSC file. The information needs to be set when commissioning a new BSC. This is particularly useful in a network where different BSCs may belong to different time zones. 5 Change the clock to summer time/standard time (DTC). ZDTC; 6 Restart the system (USS). ZUSS:SYM:C=DSK; 62 DN0982859 Issue: 01G Commissioning mcBSC Appendix 12 Appendix 12.1 Verifying LEDs After BCN recovery all units should be at M4 state. The below table describes the LED status in each state of the module. P1 – P8 LEDs on the BCN front panel indicate the state of the add-in card and the corresponding functional unit as described in the following tables Table 12 BCN LED status State Description LED status M0 FRU not installed OFF M1 FRU installed but inactive Blue M2 Waiting for activation request (see M4 state in Blue the below table) M3 Activation in progress Blue M4 Active Red / Green M5 Waiting for deactivation request Red M6 Deactivation in progress Red When the add-in card is in active state (M4), the working state of the functional unit is indicated as follows: Table 13 LED status according to unit working state Unit state LED status SE-xx Green, blinking TE-xx Green, blinking SP-xx Green, steady BL xx Green, steady WO-xx Green, steady 12.2 Factory switch configuration Issue: 01G DN0982859 63 Appendix Commissioning mcBSC 12.2.1 BOX 1 main switch F ^A g ^A !*************************************************************** !*** THIS IS FACTORY SETTINGS FOR THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE M1 BCN MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** File name: SA_Main_1.TXT !*************************************************************** !*** !***VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Prompt MainSwitch1 !! !* ISDP disabled(Cisco CDP) no isdp run ! !*************************************************************** ! ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** interface 0/3 to protected group prot_group_1 !i nterface 0/3 switchport protected 1 exit !*** interface 0/4 to protected group prot_group_1 !i nterface 0/4 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** 64 DN0982859 Issue: 01G Commissioning mcBSC Appendix !*************************************************************** interface 0/3 description to_extension_switch_0/26 exit interface 0/4 description to_extension_switch_0/25 exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+1, SFP+2, SFP+3, SFP+4 & SFP+5 !*** !*************************************************************** interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter Issue: 01G DN0982859 65 Appendix Commissioning mcBSC exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** 10GE interface to Site Equipment !*** SFP+6 !*** !*************************************************************** interface 0/2 description sfp+6_to_site_equipment exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,800 vlan tagging 800 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 66 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 Issue: 01G DN0982859 67 Appendix Commissioning mcBSC vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit 68 DN0982859 Issue: 01G Commissioning mcBSC Appendix interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20,800 vlan tagging 20,800 vlan ingressfilter exit interface 0/20 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/26 description amc#2 no shutdown exit interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 Issue: 01G DN0982859 69 Appendix Commissioning mcBSC vlan acceptframe vlanonly vlan ingressfilter exit interface 0/28 description amc#1 no shutdown exit 12.2.2 BOX 2 main switch F ? g ? !*************************************************************** !*** THIS IS FACTORY SETTINGS FOR THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE M2 BCN MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** File name: SA_Main_2.TXT !*************************************************************** !*** !*** VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Prompt MainSwitch2 ! !* Disabled ISDP (Cisco CDP) no isdp run ! !*************************************************************** ! ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** interface 0/3 to protected group prot_group_1 !i nterface 0/3 switchport protected 1 exit ! !*** interface 0/4 to protected group prot_group_1 70 DN0982859 Issue: 01G Commissioning mcBSC Appendix !i nterface 0/4 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 exit interface 0/4 description to_extension_switch_0/25 exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+1, SFP+2, SFP+3, SFP+4 & SFP+5 !*** !*************************************************************** interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 Issue: 01G DN0982859 71 Appendix Commissioning mcBSC description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** 10GE interface to Site Equipment !*** SFP+6 !*** !*************************************************************** interface 0/2 description sfp+6_to_site_equipment exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit 72 DN0982859 Issue: 01G Commissioning mcBSC Appendix interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 Issue: 01G DN0982859 73 Appendix Commissioning mcBSC vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 74 DN0982859 Issue: 01G Commissioning mcBSC Appendix no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20,800 vlan tagging 20,800 vlan ingressfilter exit interface 0/20 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/26 description amc#2 no shutdown exit interface 0/27 Issue: 01G DN0982859 75 Appendix Commissioning mcBSC description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/28 description amc#1 no shutdown exit 12.2.3 BOX 1 and 2 extension switch F ^A g ^A !*************************************************************** !*** THIS IS FACTORY SETTINGS FOR THE CONTROL AND !*** MANAGEMENT SETUP INTO THE EXT SWITCH IN THE M1&2 BCN MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** File name: SA_Ext_1&2.txt !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !*Prompt ExtensionSwitch !! !* Disabled ISDP (Cisco CDP) no isdp run ! !*************************************************************** ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** add interface 0/25 to protected group prot_group_1 !i nterface 0/25 switchport protected 1 exit ! !*** add interface 0/26 to protected group prot_group_1 !i nterface 0/26 switchport protected 1 exit ! !*************************************************************** 76 DN0982859 Issue: 01G Commissioning mcBSC Appendix !*** !*** Interfaces between Extension and Main switches !*** !*************************************************************** interface 0/25 description to_main_switch_0/4 exit interface 0/26 description to_main_switch_0/3 exit ! !*************************************************************** !*** !*** Configuration of External interfaces SFP7-SFP22 !*** !*************************************************************** interface 0/1 description sfp7 exit interface 0/2 description sfp8 exit interface 0/3 description sfp9 exit interface 0/4 description sfp10 exit interface 0/5 description sfp11 exit interface 0/6 description sfp12 exit interface 0/7 description sfp13 exit interface 0/8 description sfp14 exit interface 0/9 description sfp15 exit interface 0/10 description sfp16 exit interface 0/11 description sfp17 exit interface 0/12 description sfp18 exit interface 0/13 description sfp19 exit interface 0/14 description sfp20 Issue: 01G DN0982859 77 Appendix Commissioning mcBSC exit interface 0/15 description sfp21 exit interface 0/16 description sfp22 exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/17 description amc#2 no shutdown exit interface 0/18 description amc#2 no shutdown exit interface 0/19 description amc#2 no shutdown exit interface 0/20 description amc#2 no shutdown exit interface 0/21 description amc#1 no shutdown exit interface 0/22 description amc#1 no shutdown exit interface 0/23 description amc#1 no shutdown exit interface 0/24 description amc#1 no shutdown exit 12.2.4 TRX extension box main switch F ^A g ^A !*************************************************************** !*** THIS IS FACTORY SETTINGS FOR THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE TRX EXTENSION BCN MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** File name: SA_Main_TRX_ext.txt ! 78 DN0982859 Issue: 01G Commissioning mcBSC Appendix !*************************************************************** !*** !*** VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Prompt TRXMainSwitch ! ! !* Disabled ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+1, SFP+2, SFP+3, SFP+4 & SFP+5 !*** !*************************************************************** interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 Issue: 01G DN0982859 79 Appendix Commissioning mcBSC description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** 10GE interface SFP+6 !*** !*************************************************************** interface 0/2 shutdown exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** 80 DN0982859 Issue: 01G Commissioning mcBSC Appendix !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 Issue: 01G DN0982859 81 Appendix Commissioning mcBSC vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown 82 DN0982859 Issue: 01G Commissioning mcBSC Appendix auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/20 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch Issue: 01G DN0982859 83 Appendix Commissioning mcBSC no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/26 description amc#2 no shutdown exit interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/28 description amc#1 no shutdown exit 12.2.5 PS extension box main switch F ^A g ^A !*************************************************************** !*** THIS IS FACTORY SETTINGS FOR THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THEPS EXTENSION BCN MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** File name: SA_Main_PS_ext.TXT !*************************************************************** !*** !*** VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling 84 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configurationv!*** !***************************************************************v!* Prompt PSMainSwitch !! !* Disablde ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+1, SFP+2, SFP+3, SFP+4 & SFP+5 !*** !*************************************************************** interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 Issue: 01G DN0982859 85 Appendix Commissioning mcBSC no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** 10GE interface SFP+6 !*** !*************************************************************** interface 0/2 shutdown exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 86 DN0982859 Issue: 01G Commissioning mcBSC Appendix description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 Issue: 01G DN0982859 87 Appendix Commissioning mcBSC vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_if0 no shutdown auto-negotiate mtu 1538 88 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/20 description to_add-in_card_1_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interfaces !*** Issue: 01G DN0982859 89 Appendix Commissioning mcBSC !*************************************************************** interface 0/26 description amc#2 no shutdown exit interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/28 description amc#1 no shutdown exit 12.2.6 BCN-B BOX 1 main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE M1 BCN-B MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.1 !*** File name: init_fp.txt !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt MainSwitch1 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run 90 DN0982859 Issue: 01G Commissioning mcBSC Appendix ! !*************************************************************** ! ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** add interface 0/3 to protected group prot_group_1 ! interface 0/3 switchport protected 1 exit ! !*** add interface 0/4 to protected group prot_group_1 ! interface 0/4 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 exit interface 0/4 description to_extension_switch_0/25 exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 Issue: 01G DN0982859 91 Appendix Commissioning mcBSC vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly 92 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,800 vlan tagging 800 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 Issue: 01G DN0982859 93 Appendix Commissioning mcBSC vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_el0 no shutdown auto-negotiate mtu 1538 94 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20,800 vlan tagging 20,800 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter Issue: 01G DN0982859 95 Appendix Commissioning mcBSC exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 96 DN0982859 Issue: 01G Commissioning mcBSC Appendix 12.2.7 BCN-B BOX 1 extension switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE EXTENSION SWITCH IN THE M1 !*** BCN-B MODULES OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp_ext.txt !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt ExtensionSwitch1 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** add interface 0/25 to protected group prot_group_1 ! interface 0/25 switchport protected 1 exit ! !*** add interface 0/26 to protected group prot_group_1 ! interface 0/26 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Extension and Main switches !*** !*************************************************************** interface 0/25 description to_main_switch_0/4 exit interface 0/26 description to_main_switch_0/3 exit ! !*************************************************************** !*** !*** Configuration of External interfaces SFP11-SFP22 Issue: 01G DN0982859 97 Appendix Commissioning mcBSC !*** !*************************************************************** interface 0/27 description sfp+11 exit interface 0/28 description sfp+12 exit interface 0/7 description sfp13 exit interface 0/8 description sfp14 exit interface 0/9 description sfp15 exit interface 0/10 description sfp16 exit interface 0/11 description sfp17 exit interface 0/12 description sfp18 exit interface 0/13 description sfp19 exit interface 0/14 description sfp20 exit interface 0/15 description sfp21 exit interface 0/16 description sfp22 exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/5 description amc#2 no shutdown exit interface 0/17 description amc#2 no shutdown exit interface 0/18 description amc#2 no shutdown exit interface 0/19 description amc#2 98 DN0982859 Issue: 01G Commissioning mcBSC Appendix no shutdown exit interface 0/20 description amc#2 no shutdown exit interface 0/6 description amc#1 no shutdown exit interface 0/21 description amc#1 no shutdown exit interface 0/22 description amc#1 no shutdown exit interface 0/23 description amc#1 no shutdown exit interface 0/24 description amc#1 no shutdown exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.8 BCN-B BOX 2 main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE M2 BCN-B MODULE !*** OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! Issue: 01G DN0982859 99 Appendix Commissioning mcBSC !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt MainSwitch2 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** ! ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** add interface 0/3 to protected group prot_group_1 ! interface 0/3 switchport protected 1 exit ! !*** add interface 0/4 to protected group prot_group_1 ! interface 0/4 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 exit interface 0/4 description to_extension_switch_0/25 exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 100 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 Issue: 01G 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 DN0982859 101 Appendix Commissioning mcBSC vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 102 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate Issue: 01G DN0982859 103 Appendix Commissioning mcBSC mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20,800 vlan tagging 20,800 104 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan ingressfilter exit interface 0/26 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! Issue: 01G DN0982859 105 Appendix Commissioning mcBSC !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.9 BCN-B BOX 2 extension switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE EXTENSION SWITCH IN THE M2 !*** BCN-B MODULES OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp_ext.txt !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt ExtensionSwitch2 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** ! MAIN-EXT ports configured as protected ports to prevent ! Ethernet loop creation. ! !*************************************************************** switchport protected 1 name prot_group_1 ! !*** add interface 0/25 to protected group prot_group_1 ! interface 0/25 switchport protected 1 exit ! !*** add interface 0/26 to protected group prot_group_1 ! interface 0/26 switchport protected 1 exit ! !*************************************************************** !*** !*** Interfaces between Extension and Main switches !*** !*************************************************************** interface 0/25 description to_main_switch_0/4 exit 106 DN0982859 Issue: 01G Commissioning mcBSC Appendix interface 0/26 description to_main_switch_0/3 exit ! !*************************************************************** !*** !*** Configuration of External interfaces SFP11-SFP22 !*** !*************************************************************** interface 0/27 description sfp+11 exit interface 0/28 description sfp+12 exit interface 0/7 description sfp13 exit interface 0/8 description sfp14 exit interface 0/9 description sfp15 exit interface 0/10 description sfp16 exit interface 0/11 description sfp17 exit interface 0/12 description sfp18 exit interface 0/13 description sfp19 exit interface 0/14 description sfp20 exit interface 0/15 description sfp21 exit interface 0/16 description sfp22 exit !*************************************************************** !*** !*** AMC interfaces !*** !*************************************************************** interface 0/5 description amc#2 no shutdown exit interface 0/17 description amc#2 no shutdown Issue: 01G DN0982859 107 Appendix Commissioning mcBSC exit interface 0/18 description amc#2 no shutdown exit interface 0/19 description amc#2 no shutdown exit interface 0/20 description amc#2 no shutdown exit interface 0/6 description amc#1 no shutdown exit interface 0/21 description amc#1 no shutdown exit interface 0/22 description amc#1 no shutdown exit interface 0/23 description amc#1 no shutdown exit interface 0/24 description amc#1 no shutdown exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.10 BCN-B TRX extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN THE TRX EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_TRX_ext.scr) ! !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** 108 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt TRXMainSwitch3 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 Issue: 01G DN0982859 109 Appendix Commissioning mcBSC vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include 110 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 Issue: 01G DN0982859 111 Appendix Commissioning mcBSC vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate 112 DN0982859 Issue: 01G Commissioning mcBSC Appendix mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter Issue: 01G DN0982859 113 Appendix Commissioning mcBSC exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 114 DN0982859 Issue: 01G Commissioning mcBSC Appendix 12.2.11 BCN-B 2.TRX extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN 2.TRX EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_TRX_ext.scr) ! !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt TRXMainSwitch4 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** Issue: 01G DN0982859 115 Appendix Commissioning mcBSC interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 116 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 DN0982859 Issue: 01G Commissioning mcBSC Appendix no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 Issue: 01G DN0982859 117 Appendix Commissioning mcBSC description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 118 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate Issue: 01G DN0982859 119 Appendix Commissioning mcBSC mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** 120 DN0982859 Issue: 01G Commissioning mcBSC Appendix !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.12 BCN-B 3.TRX extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN A 3.TRX EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_TRX_ext.scr) ! !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt TRXMainSwitch5 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 Issue: 01G DN0982859 121 Appendix Commissioning mcBSC shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit 122 DN0982859 Issue: 01G Commissioning mcBSC Appendix interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 Issue: 01G DN0982859 123 Appendix Commissioning mcBSC vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 124 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/18 Issue: 01G DN0982859 125 Appendix Commissioning mcBSC description to_add-in_card_2_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_el0 no shutdown auto-negotiate mtu 1538 vlan pvid 5 vlan participation exclude 1 vlan participation include 5,20 vlan tagging 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_el1 no shutdown auto-negotiate mtu 1538 vlan pvid 6 vlan participation exclude 1 vlan participation include 6 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate 126 DN0982859 Issue: 01G Commissioning mcBSC Appendix spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.13 BCN-B 1. PS extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN A 1.PS EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_PS_ext.scr) !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt PSMainSwitch6 ! Issue: 01G DN0982859 127 Appendix Commissioning mcBSC ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter 128 DN0982859 Issue: 01G Commissioning mcBSC Appendix exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 Issue: 01G DN0982859 129 Appendix Commissioning mcBSC vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown 130 DN0982859 Issue: 01G Commissioning mcBSC Appendix auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit Issue: 01G DN0982859 131 Appendix Commissioning mcBSC interface 0/17 description to_add-in_card_2_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter 132 DN0982859 Issue: 01G Commissioning mcBSC Appendix exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.14 BCN-B 2.PS extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN A 2.PS EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_PS_ext.scr) !*************************************************************** !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt Issue: 01G DN0982859 133 Appendix Commissioning mcBSC exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt PSMainSwitch7 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit 134 DN0982859 Issue: 01G Commissioning mcBSC Appendix interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** Issue: 01G DN0982859 135 Appendix Commissioning mcBSC !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown 136 DN0982859 Issue: 01G Commissioning mcBSC Appendix auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit Issue: 01G DN0982859 137 Appendix Commissioning mcBSC interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 138 DN0982859 Issue: 01G Commissioning mcBSC Appendix description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit 12.2.15 BCN-B 3.PS extension box main switch !*************************************************************** !*** THIS SCRIPT IS USED FOR CONFIGURING THE CONTROL AND !*** MANAGEMENT SETUP INTO THE MAIN SWITCH IN A 3.PS EXTENSION BCN-B !*** MODULE OF A STANDALONE mcBSC SETUP. !*** !*** Script version 1.0 !*** File name: init_fp.txt (original SA_Main_PS_ext.scr) !*************************************************************** Issue: 01G DN0982859 139 Appendix Commissioning mcBSC !*** !*** Creation of VLANs to the VLAN database. !*** !*************************************************************** vlan database vlan 5,6,20,800 vlan name 5 mc-emb0 vlan name 6 mc-emb1 vlan name 20 signalling vlan name 800 mc-mgmt exit ! !*************************************************************** !*** !*** General configuration !*** !*************************************************************** !* Set Prompt set prompt PSMainSwitch8 ! ! configure !* Disable ISDP (Cisco CDP) no isdp run ! !*************************************************************** !*** !*** Interfaces between Main and Extension switches !*** !*************************************************************** interface 0/3 description to_extension_switch_0/26 shutdown exit interface 0/4 description to_extension_switch_0/25 shutdown exit ! !*************************************************************** !*** !*** Inter-BCN 10G interfaces !*** SFP+0, SFP+1, SFP+2, SFP+3, SFP+4, SFP+5 & SFP+6 !*** !*************************************************************** interface 0/20 description sfp+0 no shutdown no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/21 140 DN0982859 Issue: 01G Commissioning mcBSC Appendix description sfp+1 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/22 description sfp+2 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/23 description sfp+3 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/24 description sfp+4 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/1 description sfp+5 no shutdown no auto-negotiate mtu 1538 vlan participation exclude vlan participation include vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit interface 0/2 description sfp+6 no shutdown Issue: 01G 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 1 5,6,20,800 DN0982859 141 Appendix Commissioning mcBSC no auto-negotiate mtu 1538 vlan participation exclude 1 vlan participation include 5,6,20,800 vlan tagging 5,6,20,800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Configuration of Add-In card interfaces !*** !*************************************************************** interface 0/5 description to_add-in_card_8_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/6 description to_add-in_card_8_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/7 description to_add-in_card_7_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/8 description to_add-in_card_7_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/9 description to_add-in_card_6_if0 no shutdown 142 DN0982859 Issue: 01G Commissioning mcBSC Appendix auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/10 description to_add-in_card_6_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/11 description to_add-in_card_5_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/12 description to_add-in_card_5_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/13 description to_add-in_card_4_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/14 description to_add-in_card_4_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit Issue: 01G DN0982859 143 Appendix Commissioning mcBSC interface 0/15 description to_add-in_card_3_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/16 description to_add-in_card_3_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/17 description to_add-in_card_2_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/18 description to_add-in_card_2_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/19 description to_add-in_card_1_if0 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 vlan participation include 20 vlan ingressfilter exit interface 0/26 description to_add-in_card_1_if1 no shutdown auto-negotiate mtu 1538 vlan pvid 20 vlan participation exclude 1 144 DN0982859 Issue: 01G Commissioning mcBSC Appendix vlan participation include 20 vlan ingressfilter exit ! !*************************************************************** !*** !*** Interface between Main and Management switches !*** !*************************************************************** interface 0/25 description to_mgmt_switch no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit !*************************************************************** !*** !*** AMC interface !*** !*************************************************************** interface 0/27 description ptum no shutdown auto-negotiate spanning-tree bpdufilter mtu 1538 vlan participation exclude 1 vlan participation include 800 vlan tagging 800 vlan acceptframe vlanonly vlan ingressfilter exit ! !*************************************************************** !*** !*** Trace interface !*** !*************************************************************** interface 0/28 description trace exit ! !*************************************************************** !*** !*** Exit and save configuration !*** !*************************************************************** exit Issue: 01G DN0982859 145