Uploaded by konduru.rao

Ericsson Basic Question and Answers

advertisement
Ericsson Basic Question and Answers
1. How Many E1’s in one STM?
a) 62 b) 63 c) 61. d) 64
2. How many channels are there in one E1?
a) 32 b) 31 c) 30. d) 28
3. The data rate of E1 is about ____ megabits per second?
a) 2.048 b) 1.544 c) 1.292 d) 2.342
4. Among 32 channels 2 channels are reserved for..?
a) Carrier and controlling b) Signaling and controlling c) Signaling and processing
d) Modulation and controlling
5. What is Interface?
a) It refers to the connecting point between 2 adjacent network entities
b) It’s a set of rules to be defined for exchanging information between connecting
points
c) Signaling between subscriber terminal (telephone) & the local exchange
d) None of the above
6. The Air Interface is the interface between?
a) BTS&MS b) BTS&BSC c) BTS&MSC d) BSC&MSC
C2 – Vodafone Idea Internal
7. Interface between the BSC (Base Station Controller) and the BTS?
a) Abis interface b) A interface c) B interface d) D interface
8) Abbreviation for MSS?
a) Mobile Switching signal b) Mobile Switching system c) Mobile sub System d)
Mobile Switching Server
9. Abbreviation for BTS?
a)Base Transceiver Station b)Base Transceiver System c)Base Transceiver Signal
d)Base Transceiver server
10. Um Interface between?
a) BTS&MS b) BTS&BSC c) BTS&MSC d) BSC&MSC
11. Abbreviation for MAP?
a) Message Application Part b) Mobile Application Protocol c) Mobile Application
Part d) Mobile Authentication Part
12. GVMP4 hardware MGW TUB board in which Magazine?
a) Main b) CTRL c) ES1 d) ES2
13. In Ericsson MGW CMXB board is used for?
a) Power card b) IP connectivity c) inter sub rack connectivity d) Clock connectivity
C2 – Vodafone Idea Internal
14. In Ericsson MGW TUB board is used for?
a) Power card b) IP connectivity c) inter sub rack connectivity d) Clock connectivity
15. In Ericsson MGW SCB-TF board is used for?
a) Power card b) IP connectivity c) inter sub rack connectivity d) Clock connectivity
16. In Ericsson MSS GEA board is used for?
a) Alarm monitor b) External Alarm extension c) call connectivity d) Clock
connectivity
17. How Many Adjunct Processor defined in Blade cluster node?
a) 1 b) 2 c) 3 d) 4
18. How Many Central Processor defined in Blade cluster node?
a) 1 b) 2 c) 3 d) 4
19. How Many Adjunct Processor Unit Board present in Blade cluster node?
a) 1 b) 2 c) 3 d) 4
20. How Many Central Processor Unit Board present in Blade cluster node?
a) 1 b) 2 c) 3 d) 4
C2 – Vodafone Idea Internal
S.no Question
Answers
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
B
A
A
B
A
A
A
B
A
A
C
A
C
D
A
B
B
B
D
D
C2 – Vodafone Idea Internal
C2 – Vodafone Idea Internal
Download