September 08 2020 10:15 AM NO. SHEET TITLE 1 TOC DRAWING INDEX 2 MAT BASIS OF DESIGN MATERIALS 3 BE-01 EXTERIOR WALL ASSEMBLY 4 BE-02A TYPICAL WINDOW HEAD 5 BE-02A(ALT) TYPICAL WINDOW HEAD WITH RETAINER CLIP 6 BE-02B TYPICAL WINDOW JAMB 7 BE-02C TYPICAL WINDOW SILL 8 BE-02C(ALT) ALTERNATE WINDOW SILL 9 BE-03A WINDOW FLASHING SEQUENCE 10 BE-03B WINDOW FLASHING SEQUENCE 11 BE-03C WINDOW FLASHING SEQUENCE 12 BE-03D WINDOW FLASHING SEQUENCE 13 BE-03E WINDOW FLASHING SEQUENCE 14 BE-04A TYPICAL HOLLOW METAL DOOR (HMD) HEAD 15 BE-04B TYPICAL HOLLOW METAL DOOR (HMD) JAMB 16 BE-04C TYPICAL HOLLOW METAL DOOR (HMD) SILL 17 BE-05 PACKAGED TERMINAL AIR CONDITIONER 18 BE-06A WALL MOUNT HEATING/COOLING UNIT - PENETRATION AT HEAD 19 BE-6B WALL MOUNT HEATING/COOLING UNIT - PENETRATION AT JAMB ORIGINAL PRINT SIZE: 8.5" x 11" PLOT DATE: DRAWING INDEX © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: DRAWING INDEX DRAWING NO: TOC CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:15 AM PLOT DATE: BASIS OF DESIGN MATERIALS CODE USE PRODUCT DCS Drainage Course Strips (DCS) Keene Driwall Rainscreen - 10mm WRB Water Resistive Barrier Tyvek Commercial Wrap WRB-T Water Resistive Barrier Tape Tyvek Tape SAM Self Adhered Membrane 3M 3015 IVB Interior Air/Vapour Barrier 6 Mil Polyethylene IVB-S Interior Air/Vapour Barrier Sealant Chemtron Metaseal IVB-T Interior Air/Vapour Barrier Tape Tuck Tape - Sheathing Tape for Polyethylene Vapour Barrier WIN-S Window Perimeter Sealant Chemtrom Multiseal Silicone Sealant BR Backer Rod Soft Type FT Foil Tape Cantech Aluminum Foil Tape MFI Mineral Fibre Insulation Johns Manville - R-22 Fiberglass Batt MFL Metal Flashing 26 Gauge Galvalume Prefinished Metal Window All-Weather Windows Alpine 6700, Terra 2700 Hollow Metal Door Vision Hollow Metal Ltd Thermally Broken Galvannealed Steel ORIGINAL PRINT SIZE: 8.5" x 11" HMD © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: MATERIALS INDEX DRAWING NO: MAT CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: VERTICALLY PROFILED PRE-FINISHED METAL CLADDING SYSTEM OVER INTERMITTENT HORIZONTAL DRAINAGE COURSE (DCS) STRIPS TO PROVIDE DRAINED AND VENTILATED RAINSCREEN CAVITY MECHANICALLY ATTACHED SHEET APPLIED WATER-RESISTIVE BARRIER (WRB) MEMBRANE - INSTALL IN ACCORDANCE WITH MANUFACTURER GUIDELINES INCLUDING 8" VERTICAL AND HORIZONTAL LAPS, ALL TAPED 8" TYP. 15/32" ORIENTED STRAND BOARD SHEATHING OVER 2x6 WOOD FRAMED WALL MINERAL FIBRE INSULATION (MFI) (R-22) WATER-RESISTIVE BARRIER TAPE (WRB-T) AT ALL WRB LAPS, SEAMS, AND TERMINATIONS 6-MIL POLYETHYLENE AIR AND VAPOUR BARRIER (IVB) MEMBRANE ALL LAPS AND TERMINATIONS TO BE SEALED WITH CONTINUOUS AIR BARRIER TAPE (IVB-T) OR ACOUSTICAL SEALANT (IVB-S) ORIGINAL PRINT SIZE: 8.5" x 11" INTERIOR EXTERIOR VINYL COATED GYPSUM BOARD TOTAL EFFECTIVE CLEAR FIELD R-VALUE: R-17.4 (Rsi-3.1) PLAN VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: EXT. WALL ASSEMBLY DRAWING NO: BE-01 CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: WINDOW FRAME EXTENSION JOINTS AT MITERS AND ATTACHMENT TO WINDOW FRAME TO BE SEALED AIR AND WATER TIGHT BE-02A WINDOW FRAME HEAD, JAMB, AND SILL ATTACHMENT PER WINDOW MANUFACTURER BE-02B PRIOR TO INSTALLATION, WINDOW SILL FLANGE NOTCHED FOR DRAINAGE. 1" NOTCH AT 16" AND DIRECTLY ADJACENT TO EVERY JAMB AND VERTICAL MULLION. USE PAN HEAD SCREWS TO PROVIDE DRAINAGE GAP BETWEEN NOTCHED FLANGE AND METAL J-TRIM MAXIMUM 16" O.C. INSTALL WINDOW SHIMS PER WINDOW MANUFACTURER - OFFSET SHIMS FROM NOTCHES. SHIMS SHOULD NOT BLOCK DRAINAGE PATH AT NOTCHES AND SHOULD BE ORIENTED TO DRAIN. ORIGINAL PRINT SIZE: 8.5" x 11" BE-02C ELEVATION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: TYPICAL WINDOW ELEVATION DRAWING NO: BE-02 CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing EXTERIOR INTERIOR September 08 2020 10:16 AM PLOT DATE: INTERMITTENT DRAINAGE COURSE (DCS) STRIPS WATER-RESISTIVE BARRIER (WRB) CONTINUOUS AIR BARRIER SEALANT (WIN-S) BETWEEN POLY AND WOOD FRAMING WATER-RESISTIVE BARRIER TAPE (WRB-T) SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB FLANGES METAL J-TRIM WITH DRAINAGE OPENING AT EITHER END (INSET) - SEE SHEET BE-03I PREFINISHED SHEET METAL FLASHING (MFL) WITH END DAM OVER WATER-RESISTIVE BARRIER (WRB) ORIGINAL PRINT SIZE: 8.5" x 11" WATER-RESISTIVE BARRIER TAPE (WRB-T) INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT WINDOW PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP GENERAL NOTE: SEE WINDOW FLASHING ISOMETRIC (BE-05 SERIES) FOR MEMBRANE AND WINDOW INSTALLATION SEQUENCE SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW HEAD DRAWING NO: BE-02A CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing EXTERIOR INTERIOR September 08 2020 10:16 AM PLOT DATE: INTERMITTENT DRAINAGE COURSE (DCS) STRIPS WATER-RESISTIVE BARRIER (WRB) CONTINUOUS AIR BARRIER SEALANT (WIN-S) BETWEEN POLY AND WOOD FRAMING WATER-RESISTIVE BARRIER TAPE (WRB-T) SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB FLANGES FASTENER PER WINDOW SHOP DRAWINGS OR WINDOW SUPPLIER METAL J-TRIM WITH DRAINAGE OPENING AT EITHER END (INSET) - SEE SHEET BE-03I PREFINISHED SHEET METAL FLASHING (MFL) OVER WATER-RESISTIVE BARRIER (WRB) SHEET METAL WINDOW ATTACHMENT CLIP IN ACCORDANCE WITH WINDOW MANUFACTURER ORIGINAL PRINT SIZE: 8.5" x 11" WATER-RESISTIVE BARRIER TAPE (WRB-T) INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT WINDOW PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP GENERAL NOTE: SEE WINDOW FLASHING ISOMETRIC (BE-05 SERIES) FOR MEMBRANE AND WINDOW INSTALLATION SEQUENCE SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW HEAD (ALTERNATE) DRAWING NO: BE-02A(ALT) CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: INTERIOR INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT WINDOW PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP WATER-RESISTIVE BARRIER (WRB) SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB FLANGES - MINIMUM 4" WIDE ORIGINAL PRINT SIZE: 8.5" x 11" EXTERIOR BACKER ROD (BR) AND SEALANT METAL J-TRIM GENERAL NOTE: SEE WINDOW FLASHING ISOMETRIC (BE-05 SERIES) FOR MEMBRANE AND WINDOW INSTALLATION SEQUENCE PLAN VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW JAMB DRAWING NO: BE-02B CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT WINDOW PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP CONTINUOUS SEALANT PLOT DATE: CONTINUOUS OSB BACK DAM BACKER ROD (BR) AND SEALANT METAL J-TRIM INSTALLED TO THE UNDERSIDE OF THE WINDOW FRAME WINDOW SILL FLANGE NOTCHED FOR DRAINAGE. 1" NOTCH AT 16" AND DIRECTLY ADJACENT TO EVERY JAMB AND VERTICAL MULLION. USE PAN HEAD SCREWS TO PROVIDE DRAINAGE GAP BETWEEN NOTCHED FLANGE AND METAL J-TRIM INTERMITTENT SHIMS IN ACCORDANCE WITH WINDOW MANUFACTURER'S REQUIREMENTS DRAINAGE COURSE (DCS) AT FACE OF METAL J-TRIM EXTERIOR INTERIOR ORIGINAL PRINT SIZE: 8.5" x 11" SELF-ADHERED MEMBRANE (SAM) GENERAL NOTE: SEE WINDOW FLASHING ISOMETRIC (BE-05 SERIES) FOR MEMBRANE AND WINDOW INSTALLATION SEQUENCE SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW SILL DRAWING NO: BE-02C CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT WINDOW PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP PLOT DATE: WINDOW FRAME EXTENSION JOINTS AT MITERS (BEYOND) AND ATTACHMENT TO WINDOW FRAME TO BE SEALED AIR/WATER TIGHT BACKER ROD (BR) AND SEALANT METAL J-TRIM INSTALLED TO THE UNDERSIDE OF THE WINDOW FRAME WINDOW SILL FLANGE NOTCHED FOR DRAINAGE. 1" NOTCH AT 16" AND DIRECTLY ADJACENT TO EVERY JAMB AND VERTICAL MULLION. USE PAN HEAD SCREWS TO PROVIDE DRAINAGE GAP BETWEEN NOTCHED FLANGE AND METAL J-TRIM INTERMITTENT SHIMS IN ACCORDANCE WITH WINDOW MANUFACTURER'S REQUIREMENTS DRAINAGE COURSE (DCS) AT FACE OF METAL J-TRIM EXTERIOR INTERIOR ORIGINAL PRINT SIZE: 8.5" x 11" SELF-ADHERED MEMBRANE (SAM) GENERAL NOTE: SEE WINDOW FLASHING ISOMETRIC (BE-05 SERIES) FOR MEMBRANE AND WINDOW INSTALLATION SEQUENCE SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW SILL (ALTERNATE) DRAWING NO: BE-02C(ALT) CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: ORIGINAL PRINT SIZE: 8.5" x 11" WATER-RESISTIVE BARRIER (WRB) GUSSET AT HEAD CORNERS ISOMETRIC VIEW 1 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03A CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM ORIGINAL PRINT SIZE: 8.5" x 11" PLOT DATE: CUT WRB MEMBRANE AT WINDOW ROUGH OPENING AT 45 DEGREES FROM ROUGH OPENING CORNERS - ENSURE WRB MEMBRANE RETURNS MATCH ROUGH OPENING DEPTH ISOMETRIC VIEW 2 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03B CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: WATER-RESISTIVE BARRIER TAPE (WRB-T) AT INTERIOR EDGE OF WATER-RESISTIVE BARRIER (WRB) MEMBRANE FOLD WRB MEMBRANE INTO ROUGH OPENING AND TAPE TO POLYETHYLENE SHEET ORIGINAL PRINT SIZE: 8.5" x 11" AT SILL, FOLD WRB MEMBRANE INTO ROUGH OPENING PRIOR TO INSTALLATION OF OSB BACK DAM AND TAPE TO TO POLYETHYLENE SHEET ISOMETRIC VIEW 3 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03C CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: CONTINUOUS OSB BACK DAM INSTALLED OVER WRB MEMBRANE (BE-02C) SELF-ADHERED MEMBRANE (SAM) SILL FLASHING GUSSET LAPPED OVER FACE OF WATER-RESISTIVE BARRIER (WRB) DEPTH OF SILL 2" ORIGINAL PRINT SIZE: 8.5" x 11" 3" 4" TYPICAL SELF-ADHERED MEMBRANE (SAM) DART AT SILL CORNERS ISOMETRIC VIEW 4 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03D CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: SELF-ADHERED MEMBRANE (SAM) SILL TREATMENT PART 1 OF 2 WATER-RESISTIVE BARRIER (WRB) TAPE AT SKYWARD EDGES OF SELF-ADHERED MEMBRANE (SAM) SELF-ADHERED MEMBRANE (SAM) SILL TREATMENT PART 2 OF 2 INSTALL AIR BARRIER SEALANT (WIN-S) AT SELF-ADHERED MEMBRANE (SAM) SEAMS ORIGINAL PRINT SIZE: 8.5" x 11" INSTALL CONTINUOUS AIR BARRIER SEALANT (WIN-S) AT TOP FACE OF OSB BACK DAM PRIOR TO WINDOW INSTALLATION SHIMMING IN ACCORDANCE WITH WINDOW MANUFACTURER REQUIREMENTS. ENSURE UN-OBSTRUCTED DRAINAGE PATH TO WINDOW FLANGE WEEP HOLES. ISOMETRIC VIEW 5 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03E CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: ORIGINAL PRINT SIZE: 8.5" x 11" INSTALL WINDOW FRAME OVER MEMBRANE PRESTRIPS - SECURE AT HEAD FLANGES, JAMB FLANGES, AND SILL BACKDAM PER WINDOW MANUFACTURER REQUIREMENTS ISOMETRIC VIEW 6 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03F CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: ORIGINAL PRINT SIZE: 8.5" x 11" SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB FLANGES ISOMETRIC VIEW 7 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03G CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM PLOT DATE: D C A B A. B. C. ORIGINAL PRINT SIZE: 8.5" x 11" D. ISOMETRIC VIEW 9 OF 9 © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WINDOW INSTALL SEQUENCE DRAWING NO: BE-03I CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing INSTALL WINDOW HEAD FLASHING AND WRB TAPE INSTALL JAMB J-METAL CLOSURE FOLD HEAD FLASHING END DAM OVER JAMB J-METAL CLOSURE INSTALL NOTCHED HEAD J-METAL OVER HEAD FLASHING EXTERIOR INTERIOR September 08 2020 10:16 AM PLOT DATE: WATER-RESISTIVE BARRIER (WRB) WATER-RESISTIVE BARRIER TAPE (WRB-T) SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB METAL J-TRIM WITH DRAINAGE OPENING AT EITHER END (INSET) PREFINISHED SHEET METAL FLASHING (MFL) WITH END DAM OVER WATER-RESISTIVE BARRIER (WRB) ORIGINAL PRINT SIZE: 8.5" x 11" METAL FLASHING (MFL) FILL HOLLOW METAL DOOR (HMD) FRAME WITH MINERAL FIBRE INSULATION SELF-ADHERED MEMBRANE (SAM) FROM VINYL COATED DRYWALL ONTO WRB FOR AIR BARRIER TIE-IN AIR BARRIER SEALANT (WIN-S) SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: HOLLOW METAL DOOR (HMD) HEAD DRAWING NO: BE-04A CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM SELF-ADHERED MEMBRANE (SAM) FROM VINYL COATED DRYWALL ONTO WRB FOR AIR BARRIER TIE-IN PLOT DATE: AIR BARRIER SEALANT (WIN-S) INTERIOR HOLLOW METAL DOOR (HMD) FILL HOLLOW METAL DOOR (HMD) FRAME WITH MINERAL FIBRE INSULATION SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB WATER-RESISTIVE BARRIER TAPE (WRB-T) WATER-RESISTIVE BARRIER (WRB) ORIGINAL PRINT SIZE: 8.5" x 11" EXTERIOR METAL J-TRIM METAL FLASHING (MFL) - EXTEND DOWN AND HOOK OVER SILL FLASHING PLAN VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: HOLLOW METAL DOOR (HMD) JAMB DRAWING NO: BE-04B CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM CONTINUOUS AIR BARRIER SEALANT (WIN-S) AT BACK DAM ANGLE TIED TO CONTINUOUS AIR BARRIER SEAL AT ROUGH OPENING PERIMETER PLOT DATE: SEAL JOINT BETWEEN THRESHOLD AND BASE OF DOOR (HMD) FRAME HOLLOW METAL DOOR (HMD) SILL SET INTO INTERMITTENT SHIMS AND BEADS OF AIR BARRIER SEALANT (WIN-S) OVER SELF-ADHERED MEMBRANE (SAM) SHEET METAL FLASHING (MFL) INSTALLED OVER INTERMITTENT SHIMS SELF-ADHERED FLASHING MEMBRANE LAPPED FROM METAL BACK DAM ONTO WATER-RESISTIVE BARRIER (WRB) MEMBRANE CLADDING SYSTEM OVER INTERMITTENT DRAINAGE COURSE (DCS) STRIPS ORIGINAL PRINT SIZE: 8.5" x 11" VINYL SHEET FLOORING INSTALLED PRIOR TO THRESHOLD SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: HOLLOW METAL DOOR (HMD) SILL DRAWING NO: BE-04C CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM WATER-RESISTIVE BARRIER (WRB) EXTENDING FROM EXTERIOR SHEATHING INTO ROUGH OPENING WATER-RESISTIVE BARRIER TAPE (WRB-T) PLOT DATE: PREFINISHED SHEET METAL FLASHING (MFL) OVER WATER-RESISTIVE BARRIER (WRB) - (SIM AT WINDOW HEAD CONDITIONS BE-02) SELF-ADHERED MEMBRANE (SAM) FLASHING AT HEAD AND JAMB INTERIOR BACKER ROD (BR) AND AIR BARRIER SEALANT (WIN-S) JOINT AT DUCT PERIMETER - OVERSIZE BACKER ROD (BR) 25% LARGER THAN SEALANT GAP INTERMITTENT SHIMS OVER SILL MEMBRANE FOR DRAINAGE AT DUCT SILL SLOPE CAULK ALL PTAC SLEEVE SEAMS AND BACKER ROD (BR) AND SEALANT SELF-ADHERED MEMBRANE (SAM) DRAINAGE COURSE (DCS) AT FACE OF SILL FLASHING EXTERIOR INTERIOR ORIGINAL PRINT SIZE: 8.5" x 11" INTERIOR WOOD TRIM, TYP. NOTE: WRB AND SELF-ADHERED MEMBRANE (SAM) AT MECHANICAL WALL PENETRATIONS ARE TO BE SIMILAR TO WINDOW ROUGH OPENING SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: PTAC DUCT PENETRATION DRAWING NO: BE-05 CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing WATER-RESISTIVE BARRIER TAPE (WRB-T) PLOT DATE: September 08 2020 10:16 AM EXTERIOR INTERIOR WATER-RESISTIVE BARRIER (WRB) CONTINUOUS AIR BARRIER SEALANT (WIN-S) BETWEEN POLY AND WOOD FRAMING PREFINISHED SHEET METAL FLASHING (MFL) PREFINISHED SHEET METAL METAL J-TRIM TAPE BUTYL GASKET PREFINISHED SHEET METAL FLASHING (MFL) WITH END DAM LAG BOLT THROUGH HVAC UNIT FLANGE HVAC UNIT ORIGINAL PRINT SIZE: 8.5" x 11" METAL SLEEVE WITH JOINTS SEALED CONTINUOUS TAPE FROM SHEET METAL SLEEVE TO INTERIOR FINISH FACER NOTE: WRB AND SELF-ADHERED MEMBRANE (SAM) AT MECHANICAL WALL PENETRATIONS ARE TO BE SIMILAR TO WINDOW ROUGH OPENING SECTION VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WALL MOUNT AC UNIT - HEAD DRAWING NO: BE-06A CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing September 08 2020 10:16 AM METAL J-TRIM METAL J-TRIM SET IN CONTINUOUS SEALANT OVER PREFINISHED SHEET METAL PLOT DATE: LAG BOLT THROUGH HVAC UNIT FLANGE BUTYL GASKET WATER-RESISTIVE BARRIER (WRB) EXTERIOR PREFINISHED SHEET METAL FOAM GASKET (MANUFACTURER SUPPLIED) TAPE HVAC UNIT METAL SLEEVE WITH JOINTS SEALED CONTINUOUS TAPE FROM SHEET METAL SLEEVE TO INTERIOR FINISH FACER INTERIOR ORIGINAL PRINT SIZE: 8.5" x 11" CONTINUOUS AIR BARRIER SEALANT (WIN-S) BETWEEN POLY AND WOOD FRAMING NOTE: WRB AND SELF-ADHERED MEMBRANE (SAM) AT MECHANICAL WALL PENETRATIONS ARE TO BE SIMILAR TO WINDOW ROUGH OPENING PLAN VIEW © ATCO STRUCTURES & LOGISTICS LTD. ALL RIGHTS RESERVED. THESE DRAWINGS CONTAIN CONFIDENTIAL INFORMATION AND ARE THE PROPERTY OF ATCO STRUCTURES & LOGISTICS LTD. THEY SHALL BE HELD IN STRICTEST CONFIDENCE AND CANNOT BE USED, COPIED, REPRODUCED, DISCLOSED, PUBLISHED, DISTRIBUTED OR OTHERWISE EXPLOITED, IN ANY FORM OR MANNER, IN WHOLE OR IN PART, FOR ANY REASON OTHER THAN THE REASON FOR WHICH THEY WERE PROVIDED TO YOU BY ATCO STRUCTURES & LOGISTICS LTD., WITHOUT THE EXPRESS WRITTEN CONSENT OF ATCO STRUCTURES & LOGISTICS LTD. DRAWING TITLE: WALL MOUNT AC UNIT - JAMB DRAWING NO: BE-06B CLIENT: ATCO 0 REV. 2020. 06.02 Issued for Review RDH RDH DATE DESCRIPTION BY CHK. APP. PROJECT: ATCO Enclosure Detailing