Uploaded by glainez56

TABLA DE TORQUE - PERNO ESTRUCTURAL

advertisement
Pernostock Ltda.
www.pernostock.cl
TORQUE TENSION PARA PERNOS ESTRUCTURALES
ASTM A325 - ASTM F1852 (Con recubrimiento Dacromet y Galvanizado mecánico)
ASTM A490 - ASTM F2280
TENSIÓN MÍNIMA RECOMENDADA
LOS VALORES SON 1.05 VECES QUE EL DISEÑO MIN. DE LA ASIC (American institute of steel construction)
PERNOS ASTM A325 - PTC F1852
PERNOS ASTM A490 - PTC F2280
DIAMETROS PERNO
Libras
Libras
1/2”
13,000
16,000
5/8”
20,000
25,000
3/4”
29,000
37,000
7/8”
41,000
51,000
1”
54,000
67,000
1-1/8”
59,000
84,000
1-1/4”
75,000
107,000
1-3/8”
89,000
127,000
1-1/2”
108,000
155,000
TORQUE PROMEDIO PARA PERNOS LIMPIOS Y ACEITADOS CON COEF. 0.15
VALORES QUE SIRVEN SOLO COMO GUÍA
PERNOS ASTM A325 - PTC F1852
PERNOS ASTM A490 - PTC F2280
DIAMETROS PERNO
Lbs-pie
Lbs-pie
1/2”
79
98
5/8”
155
195
3/4”
275
345
7/8”
448
565
1”
670
840
1-1/8”
825
1.180
1-1/4”
1.165
1.675
1-3/8”
1.535
2.185
1-1/2”
2.025
2.915
Los valores de torque calculados, pueden variar en la tensión del perno dependiendo de sus componentes. Para asegurar que la tensión del perno sea la adecuada,
puede ser necesario determinar el torque exacto con un “calibrador de torque”.
Esta tabla no aplica a pernos y tuercas galvanizadas en caliente.
Pernostock Ltda.
Av. Los Libertadores Nº 16, Colina, Santiago de Chile. Tel. (562) 2636 6100
www.pernostock.cl
Download