Hybrid Air-Conditioning System EVOAIR MARKETING (M) SDN BHD (1404221 - T) customer hotline Coolpressor (Outdoor Condensing Unit) Emission of cool & humid air suitable for living things room temperature air Heat Emission Control System (HECS ) EvoAir requires the lowest amount of refrigerant (R32) in the world! The conventional condenser with long copper coil has been replaced by our patent-pending HECS technology. This technology increases the efficiency of the heat transfer for the refrigerant and emission of cool and humid air to the atmosphere! The first of its kind patent-pending technology which does not contribute to the Urban Heat Island effect, resulting in a truly environmentally friendly air conditioner. In turn, turning on the air-conditioner results in cooling both the interior and exterior environments. Lowest life cycle climate performance (LCCP) which is outstanding among other refrigerants in preserving global climate changes. Protect the ozone layer as R32 has zero Ozone Depletion Potential (ODP). Lowest global warming potential (GWP). Energy Efficiency 43 - 50% higher latent heat of vaporisation than R410A, absorbing more heat to transform from liquid to vapour phases, resulting in a higher cooling capacity. 41% higher thermal conductivity in liquid form than R410A, promoting better heat transfer with water at the E-ball. Less refrigerant is required as R32 is 9% lower in density than R410A in liquid form while delivering the same cooling capacity. 9 REASONS TO BUY EVOAIR First dual functionality air conditioner Air Conditioner Blower (Indoor Unit) High cooling capacity Energy saving - Low start up current - Low running current Coolpressor (Outdoor Unit) Reduce hot-air emission (HECS ) Improves humidity giving best condition for living things and plants Modern outlook & enhance urban view Easier maintenance and servicing Easy and flexible installation Ability to work independently SPECIFICATIONS MODEL AC POWER SUPPLY COOLING CAPACITY POWER INPUT MAX POWER CONSUMPTION RELATED CURRENT MAXIMUM CURRENT STARTING CURRENT COEFFICIENT OF PERFORMANCE ENERGY EFFICIENT RATIO (EER) REFRIGERANT REFRIGERANT CHARGE OUTDOOR UNIT INDOOR UNIT V / Ph / Hz Btu/hr W W W A A A W/W Btu/hr/W TYPE Kg AIR FLOW DIMENSIONS MASS NOISE LEVEL AIR FLOW M3 / hr cm Kg dB (A) M3 / hr DIMENSIONS cm MASS NOISE LEVEL Kg dB (A) LIQUID REFRIGERANT PIPE DIAMETER mm (inch) GASEOUS REFRIGERANT PIPE DIAMETER mm (inch) INDOOR UNIT OPERATION AUTOMATIC LOUVRE DIRECTION - 2.0 HP 19896 5831 1426 1689 6.36 7.50 5.6 4.09 13.95 0.61 1.5 HP 220 - 240/1/50 Hz 15065 10394 4415 3046 993 680 1173 786 4.39 2.97 5.18 3.44 3 2 4.45 4.48 15.17 15.28 R32 0.45 0.35 1578 1200 92.5 x 35.5 x 68.5 53.7 47.7 46.3 65 60 1148 740 565 103 X 22 X 91.5 X 20 X 83 X 20.5 X 31.5 29 29.5 13 10 9 46 45 42 6.35 (0.25) 12.7 (0.5) 9.52 (0.375) LCD REMOTE CONTROL UP & DOWN * Note : all specifications are subject to change by the manufacturer without prior notice. Hybrid Air-Conditioning System Coolpressor (outdoor unit) 1.0 HP Air Conditioner Blower (indoor unit)