PD Instruments Portable Switchgear PD Solutions IPEC Ltd is a specialist engineering company based in the industrial heart of the United Kingdom, who are well renowned technological innovators within the of electrical engineering industry. Formed in 1995, the company has made great advancement in its field and IPEC are now leading specialists in Online Partial Discharge (PD) detection and location, for MV, HV and EHV cables, switchgear and accessories. Partial discharge is generally accepted as the predominant cause of long term degradation and eventual failure of electrical insulation. As a result, its measurement is standard procedure in the factory testing of many types of high voltage equipment. In addition, partial discharge activity can be tested for or monitored on in-service equipment to warn against pending insulation failure. IPEC currently have a live network of over 150 Permanent PD monitoring Systems - monitoring over 5,000 electricity assets worldwide. IPEC’s mission is to bring innovation, expertise, and outstanding products and services to the electricity supply industry. A goal IPEC continually reaches for through cutting-edge Research and Development, Knowledge Consolidation, and Listening to and Understanding customer needs and demands Par�al Discharge Instruments A significant propor�on of disrup�ve failure in substa�on assets can be prevented through PD tes�ng. Periodic tes�ng of electrical assets means that a poten�al fault can be detected and repaired before it becomes a risk to engineers or the surrounding environment. All IPEC products are designed and manufactured in accordance with ISO 9001 standards. IPEC have a dedicated team of highly skilled engineers, who are able to bring innova�ve ideas from concept to final product. IPEC only work with carefully selected partners, ensuring the highest quality in Bri�sh product manufacturing. PD-SGS PD Detector PD-SG1 TEV PD Detec�on Par�al discharge ac�vity inside metal clad high voltage plant induces small voltage impulses called Transient Earth Voltages on the surface of the metal panels. TEVs travel around the surface to the outside of the switchgear, where they can be picked up externally using a PD detector. Ultrasonic PD Detec�on Defects on the surface of high voltage insulators are prone to a phenomenon known as surface tracking. Tracking causes carbon deposits that build up over �me, ul�mately leading to flashover and insula�on failure. IPEC’s PD instruments are highly sensi�ve to the ultrasonic emissions produced by tracking and enable the on-set to be detected before insula�on failure. Our Range Detec�on Verifica�on Loca�on Level Mode is used to detect presence of both TEV and Ultrasonic ac�vity PRPD enables the user to verify PD ac�vity is genuine and not from electrical noise Dual sensor precedence mode allows users to pin point the source of the PD ac�vity online, to a resolu�on of 8 cm With the PD Detector, you can also save PD Data PD-SGS PD Detector PD-SG1 PD-SGS PD-SGS is a dual transducer PD detector for switchgear. The instrument detects TEV signals generated by internal discharge, as well as acous�c discharge generated by surface tracking or corona. The device can measure TEV signals generated by internal PD and it uses ultrasonic detec�on of surface PD ac�vity. The PD-SGS has an integrated noise detec�on algorithm to avoid false posi�ves. Level mode and trend mode can be heard through audible output, through headphones or built in speaker. What’s in the Box? PD-SGS Headphones Func�on Tester Mains Charger USB Charger Hard wearing PELI™ case Handheld Switchgear PD Spot Tester The Benefits • Rapid survey whole substa�on - detects MV and HV problems before they occur • Personnel safety device - ensure the substa�on is clear of PD before conduc�ng work • Hear the PD - only instrument available that allows the user to hear both ultrasonic and TEV PD ac�vity occur • Ergonomic and compact design - fits in the user’s pocket and is easy to use occur • Long las�ng ba�ery - allowing a whole day of tes�ng without requiring a recharge Rapid Substa�on Survey Personnel Safety Audible PD Ergonomic & Compact Long Las�ng Ba�ery Key Features • Measurement of TEV signals generated by internal PD • Ultrasonic detec�on of surface PD ac�vity • Integrated Noise Detec�on Algorithm helps avoid ‘False Posi�ves’ • Level Mode and Trend Mode • Audible output through headphones or built in speaker Detec�on Verifica�on Loca�on Level Mode is used to detect presence of both TEV and Ultrasonic ac�vity PRPD enables the user to verify PD ac�vity is genuine and not from electrical noise Dual sensor precedence mode allows users to pin point the source of the PD ac�vity online, to a resolu�on of 8 cm With the PD Detector, you can also save PD Data PD Detector PD Detector is a dual transducer test instrument, with data synchroniza�on, for switchgear. The instrument detects TEV signals generated by internal par�al discharge as well as acous�c discharge generated by surface tracking or corona. A mobile device receives data directly from the instrument for display and synchroniza�on with a central server. The user can log trend PD ac�vity against par�cular assets and it can generate automa�c ‘high PD’ alerts to a management team live from site. What’s in the Box? PD Detector Android™ Mobile Phone Headphones Func�on Tester Mains Charger USB Charger Hard wearing PELI™ case Switchgear PD Detector with Data Synchronisa�on The Benefits • Rapid survey whole substa�on - detects MV and HV problems before they occur • Remote Data Storage - ensure all data is recorded from each site test • Trend - log the PD against individual assets and view data from each test ever conducted • Advanced Noise Rejec�on - system detects PD in higher noise environments, no more false posi�ves • Ac�ve Noise Separa�on - system will ac�vely show the result of noise and PD separately on the screen • PRPD - PRPD display allows user to dis�nguish between PD and Noise Rapid Substa�on Survey Remote Data Storage PD Trend Ac�ve Noise Separa�on PRPD Key Features • Measurement of TEV signals generated by internal PD • Data synchronisa�on to central server • Log and trend PD ac�vity against par�cular assets • Automa�c data integra�on with SAP • Automa�c high PD alerts to asset management team live from site • Integrated Noise Detec�on Algorithm helps avoid ‘False Posi�ves • Separate readings for noise and PD when detec�ng PD Level Noise Level Detec�on Verifica�on Loca�on Level Mode is used to detect presence of both TEV and Ultrasonic ac�vity PRPD enables the user to verify PD ac�vity is genuine and not from electrical noise Dual sensor precedence mode allows users to pin point the source of the PD ac�vity online, to a resolu�on of 8 cm With the PD Detector, you can also save PD Data PD-SG1 PD-SG1 is a dual transducer switchgear PD detec�on instrument. The unit detect TEV signals generated by internal discharge, as well as acous�c discharge generated by surface tracking or corona. The system uses two channels to acquire TEV signals, enabling accurate loca�on of PD in switchgear. The PD-SG1 has three modes: Level Mode, used to detect presence of both TEV and ultrasonic ac�vity; Cycle Mode, Phase Resolved Par�al Discharge Display (PRPD) enables the user to verify PD ac�vity is genuine and not from electrical noise interference before taking further remedial ac�on; Precedence Mode, dual sensor precedence allows users to pin-point the source of PD ac�vity. What’s in the Box? PD-SG1 Headphones Sync Transmi�er 2x CC-TEV PD Sensor 1x AA Ultrasonic Sensor 1x HFCT 48 PD Sensor Func�on Tester Mains Charger Hard wearing PELI™ case Portable Switchgear PD Locator The Benefits • Detect MV and HV problems - before they develop into tangible failure risks • Personnel Safety Device - ensure the substa�on is clear of PD before conduc�ng work • Locate PD Source - precedence with pico second �ming accurately locates PD within Switchgear • PRPD - PRPD display allows user to dis�nguish between PD and Noise • Hear the PD - only instrument available that allows the user to hear both ultrasonic and TEV PD ac�vity Detect MV & HV Problems Personnel Safety Locate PD Source Audible PD PRPD Key Features • Integrated Noise Detec�on Algorithm helps avoid ‘False Posi�ves’ Ultrasonic detec�on of surface PD ac�vity • Displayed on the LCD screen as dB reading, as well as audible signals through headphones • Measurement of TEV signals generated by internal PD • PRPD Mode for viewing PD pa�ern in power cycle, allowing for the recogni�on of noise • Precedence Mode for loca�on of PD within the assets under test Detec�on Verifica�on Loca�on Level Mode is used to detect presence of both TEV and Ultrasonic ac�vity PRPD enables the user to verify PD ac�vity is genuine and not from electrical noise Dual sensor precedence mode allows users to pin point the source of the PD ac�vity online, to a resolu�on of 8 cm Technical Specifications TEV Measurements Sensor Measurement Range Resolution Accuracy Noise Rejection Ultrasonic Measurements Measurement Range Resolution Accuracy Transducer Sensitivity Transducer Centre Frequency Hardware Enclosure Control Connectors PD-SGS PD Detector Capacitive 0 to 80 dBmV 1 dB ±1 dB Yes Capacitive 0 to 80 dBmV 1 dB ±1 dB Yes, with PRPD -6dBµV to + 70dBµV 1 dB ±1 dB -65dB (0dB = 1volt/µbar RMS SPL) 40 kHz -6dBµV to + 70dBµV 1 dB ±1 dB -65dB (0dB = 1volt/µbar RMS SPL) 40 kHz Injection moulded plastic case Membrane keypad Power, Headphones and External Acoustic Sensor OLED with level LEDs Injection moulded plastic case Membrane keypad Power, Headphones and External Acoustic Sensor OLED with level LEDs Display Operating Environment Operating Temperature -20°C to 60°C -20°C to 60°C Humidity 60 ±25% RH non-condensing 60 ±25% RH non-condensing IP Rating 54 54 Application Communication Bluetooth Data Storage Customer Server Data Access Web front end, SAP, Oracle, etc. Capability Android Reporting Yes Results dB, PRPD, Noise Dimensions Unit Size 190 x 90 x 55 mm 190 x 90 x 55 cm Unit Weight 300 g 300 g Kit Size 295 x 340 x 145 mm 295 x 340 x 145 cm Kit Weight 2.8 kg 2.8 kg Power Internal Battery Lithium Ion, 3.75V, 2.2Ah, 8.25Wh Lithium Ion, 3.75V, 2.2Ah, 8.25Wh Operating Time Approx. 12 hours 8 hours Charging Temperature 0°C to 45°C 0°C to 45°C Battery Charger Rated Voltage 100 to 250 VAC, 5V, 3A 100 to 250 VAC, 5V, 3A Frequency 47 to 63Hz 47 to 63Hz Country Adapters UK, EU, Australia, USA UK, EU, Australia, USA Charge time 2 hours 2 hours CE-compliant in accordance with Low Voltage Directive (2014/35/EU) and EMC Directive (2014/30/EU) PD-SG1 TEV Measurements Sensor Capacitive Measurement Range 0 to 80 dBmV Resolution 1 dB Accuracy ±1 dB Noise Rejection Yes, with PRPD Ultrasonic Measurements Measurement Range -6dBµV to + 70dBµV Resolution 1 dB Accuracy ±1 dB Transducer Sensitivity -65dB (0dB = 1volt/µbar RMS SPL) Transducer Centre Frequency 40 kHz High Frequency CT (HFCT) Measurement Range 0 to 2,000,000pC Transfer Function 4.8V/A Frequency 100kHz to 13 MHz Precedence Time Resolution 240 pico-seconds Distance Resolution 85mm Power Cycle Mode Frequency 50/60Hz Display Modes Live & Infinite Persistence Linear Range Min 0 to 20mV, Max 0 to 20V dB Range 0 to 60dBmV Hardware Enclosure Tough Aluminium case, with rubber protective side panels Control Membrane keypad Connectors Power, Headphones and External TEV and Acoustic Sensor Display Back-lit LCD with precedence LEDs Operating Environment Operating Temperature -10°C to 60°C Humidity 60 ±25% R.H non-condensing IP Rating 54 Dimensions Unit Size 210 x 90 x 65 mm Unit Weight 1.8 kg Kit Size 565 x 340 x 230 mm Kit Weight 10.25 kg Power Internal Battery Lithium Ion, 12V, 4Ah, 48Wh Operating Time Approx. 8 hours Charging Temperature 0°C to 45°C Battery Charger Rated Voltage 100 to 250 VAC, 12.6V, 1.65A Frequency 50 to 60Hz Country Adapters UK, EU, Australia, USA Charge time 4 hours CE-compliant in accordance with Low Voltage Directive (2014/35/EU) and EMC Directive (2014/30/EU) www.ipec.co.uk IPEC Limited Manchester Science Park Manchester M15 6SZ United Kingdom