Company Profile HVAC Care Solutions is a professionally managed organization incorporated in 2013 and was conceived with a view to glove services in various fields, having a team of experienced engineers who have their specialization in the respective fields like Commercial Buildings, High-Rise Buildings, Industrial Facilities, Clean Rooms Application, Hospitals, Pharmaceuticals, Shopping Centers, Multiplexes & Malls etc. WE EXPERTISE IN Surveying Estimation FEED (Front End Engineering & Design) Installation Pre-Commissioning Testing & Commissioning Handing-Over Maintenance (Annual Maintenance Contracts) Services VRF/VRV AIR-CONDITIONING SYSTEMS VRV stands for “Variable Refrigerant Volume,” while VRF stands for “Variable Refrigerant Flow”. VRV is term copyrighted by Daikin, one of the true industry leaders in HVAC equipment and technology. VRF refers to the same basic technology used in those systems manufactured by other companies—Fujitsu, for one, makes some great variable refrigerant flow systems. AHU-AIR HANDLING UNIT & DE-HUMIDIFIER SYSTEMS The definition of air handling unit from ANSI/AHRI Standard 430-2009 states that it is “A factory-made encased assembly consisting of a fan or fans and other necessary equipment to perform one or more of the functions of circulating, cleaning, heating, cooling, humidifying, dehumidifying and mixing of air” A dehumidifier is an electrical appliance which reduces and maintains the level of humidity in the air, usually for health or comfort reasons, or to eliminate musty odor and to prevent the growth of mildew by extracting water from the air. DUCTABLE AIR-CONDITIONING SYSTEMS A ductable air conditioner is a split air conditioner in which conditioned air from the indoor unit is passed into the room using circular/ oval/ rectangular ducting. Ducting is fabricated either using galvanized steel or pre-insulated boards, or fabric. A ductable air conditioner is normally installed either above the conditioned room or outside. Return air is collected from the room and is passed back to the air conditioner. The space where the air is conditioned and the room are always kept air tight except for some measured volume of fresh air which is needed based on defined ventilation standards. PACKAGE AIR CONDITIONING SYSTEMS Package air conditioner is a bigger version of the window air conditioner. However, unlike window air conditioner or PTAC units, it has a higher cooling or heating capacity and is usually able to cool an entire house or a commercial building. The nominal capacities ranges from 3 ton to 15 ton. The conditioned air are transferred to the space to be conditioned through ducting which is usually hidden in the ceiling and wall of the building. The unit is placed outside the house, a special room in a building or even on top of a roof. This unit is factory assembled and skilled technicians are needed to install this type of unit. INSTALLATION OF CHILLER UNITS (LOW SITE) A chiller is a machine that removes heat from a liquid via a vapor-compression, Adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water). As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. COMPLETE DUCTING Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, supply air, return air, and exhaust air. Ducts commonly also deliver ventilation air as part of the supply air. As such, air ducts are one method of ensuring acceptable indoor air quality as well as thermal comfort. A duct system is also called ductwork. Planning (laying out), sizing, optimizing, detailing, and finding the pressure losses through a duct system is called duct design. Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. HEATING VENTILATION & AIR-CONDITIONING Heating, ventilation, and air conditioning (HVAC) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a sub discipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer. “Refrigeration” is sometimes added to the field’s abbreviation, as HVAC&R or HVACR or “ventilation” is dropped, as in HACR (as in the designation of HACR-rated circuit breakers). FIRE FIGHTING SYSTEMS A fire fighting system is probably the most important of the building services, as its aim is to protect human life and property, strictly in that order. It consists of three basic parts: a large store of water in tanks, either underground or on top of the building, called fire storage tanks. A fire alarm system has a number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present. These alarms may be activated automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points or pull stations. LPG GAS BANK & PIPELINING LPG cylinders are stored in a cylinders bank at the ground level and the regulators are installed in all the apartments. Special protected devices are installed in Gas bank. The system has multiple pressure regulation stages to supply LPG to user at low pressure and to make the system safer. Projects VRF&VRV Serviced/Construction CAPACITY IN TR & Area (Sq.Ft) HP/ Area P&G SHADNAGAR HYD TRICOLOR CONSTRUCTION HEAD OFFICE BANJARA HILLS HYD DLF BUILDING 4th FLOOR GACHIBOWLI HYD HMTV JUBLIIHILLS ROAD NO.36 HYDERABAD PACE HOSPITAL HITECH CITY AND BEGUMPET HYD KAKATIYA MEDICAL COLLEGE WARANGAL TELANGANA O.T HVAC WORK FERNANDEZ HOSPITAL UNIT 4 HYD UNDER DUCT INSULATION ONLY MAHINDRA CIE AUTOMOTIVE LTD, ZAHEERABAD DUCTED SPLIT AHU’s & CHILLER (LOW SITE) DR.REDDY'S LAB, BACHUPALLY (Multiple Projects) PACE HOSPITALS, HI-TECH CITY SAFE HOSPITAL, SUCHITRA ANNORA PHARMA PVT. LTD, ANNARAM NIRMAL DAIGNOSTIC CENTRE MEHBOOBNAGAR COMMVAULT SYSTEMS INDIA PVT LTD HYD SPICEJET AIRLINES ENGINEERING WORKSHOP SHAMSHABAD AIRPORT SANSA JEWELLERS, BANJARA HILLS, RD # 8, HYD UNIQUE FANCY SAREES MANJEERA MALL, KUKATPALLY, HYDERABAD TAMANNA MAKEUP STUDIO, RD # 36, JUBILEEHILLS, HYD KOLORS HEALTH CARE LLP MADURI,TAMILNAIDU SELAM TAMIL NAIDU CHENNAI, TAMIL NADU GUNTUR ANDRAPARDESH VIJAYNAGRAM ANDRAPRADESH VIZAG ANDARAPRADEH ATTAPUR, HYDERABAD UPPAL, HYDERABAD GACHIBOWLI, HYDERABAD KARKHANA SECUNDARABAD WARANGAL TELANGANA KAREEMNAGAR TELANGANA NIZAMABAD, TELANGANA PUNE MAHARASHTRA BELGUAM, KARNATAKA INDORE MADHYA PRADESH G PULLA REDDY ENGINEERING COLLEGE KURNOOL 350 HP 80 HP 26 HP 100 HP 150 HP 8 No's Op Theatres 10,000 Sft 40 HP Serviced/Construction CAPACITY IN TR & Area (Sq.Ft) HP/ Area 30,000 257 TR 22,000 195 TR 10,000 110 TR 25,000 220 TR 5,000 25 TR 10,000 40 TR 6,000 30 TR 4,000 5.5 TR 4,000 11 TR 3,000 11 TR 5,000 5,000 5,000 5,000 7,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 8,000 5,000 6,000 8,000 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 22 TR 30TR 40 TR 22 TR 22 TR 43 TR CASSETTE AND SPLIT A/C AIRTELOFFICE NAGUERJUNA CIRCLE HYDERABAD TANTRA THAI SPA GACHIBOWLI HYDERABAD TANTRA THAI SPA SUMAJIGUDA HYDERABAD RAYMOND SHOWROOM LB NAGAR HYDERABAD RAYMOND SHOWROOM KALWAKURTI TELANGANA MR MOIZUDDIN VILLA VIJAYNAGAR COLONY HYD MS EDUCATION SOCIETY SHALIBONDA OFFICE HYD MS EDUCATION SOCIETY MALAKPET OFFICE HYD MR KHALID VILLA KAVADIGUDA SECUNDERABAD F+S DESIGNING OFFICE BANJARA HILLS GRAND HIGHWAY RESTAURANT SHAMSHABAD HYD UNIQUE FANCY SAREES, JUBLIHILLS, RD # 36, HYDERABAD HAMEEDI SWEETS & CONFECTIONARIES, MOUZZAMJAHI MARKET, HYD EXHAUST & VENTILATION WORK IBM, HYDERABAD VIQARABAD HOTEL KITCHEN EXHAUST GRAND HOTEL, ABIDS, HYD TAMANNA MAKEUP STUDIO BANJARAHIILS,ATTAPUR AND JUBLIHILLS MANABHUM CONSTRUCTION HEAD OFFICE, JUBILEE HILLS, HYD MR JALEEL VILLA BANJARAHILLS HSBC, HITECH CTY PRECISION AIR CONDITIONER Serviced/Construction Area (Sq.Ft) 2,500 5,500 5,000 3,000 2,500 5,500 5,000 5,800 6,000 3,000 6,000 4,000 1,000 CAPACITY IN TR & HP/ Area Serviced/Construction Area (Sq.Ft) 20,000 3,000 4,000 3,000 2,000 4,000 6,000 CAPACITY IN TR & HP/ Area Serviced/Construction Area (Sq.Ft) CAPACITY IN TR & HP/ Area ACE LINE INFO PVT LTD 22 TR 46 TR 40 TR 25 TR 20 TR 20 TR 36 TR 46 TR 16 TR 25 TR 50 TR 28 TR 8 TR 200 TR EVAPORATIVE COOLING ASIAN CINEMA MAHABOOBNAGAR TELANGANA ASIAN CINEMA KAMAREDDY TELANGANA ASIAN CINEMA DILSUKHNAGAR, HYD ASIAN CINEMA KODAAD ASIAN CINEMA SHASHIKALA LAKHSMIKALA, MOOSAPET, HYD ASIAN CINEMA KOMPALLY, RANGAREDDY MEGHA ENGINEERING INFRASTRUCTURE LTD ORBICULAR PHARMA PRAGATINAGAR HYD MERIDIAN FUNCTION PALACE MALAKPET HYD Serviced/Construction Area (Sq.Ft) 5,110 5,325 5,010 5,280 5,150 5,080 5,100 8,400 10,400 CAPACITY IN TR & HP/ Area Contact Us: # 9-4-131/1/N/25, Neerja Colony, Tolichowki – 500008, Hyderabad Call Us: +91-7337449793 (Whatsapp) +91-7337449792 (Whatsapp) +91-9866282796 (Whatsapp) Mail Us: azmat@hvaccaresolutions.in naveed@hvaccaresolutions.in info@hvaccaresolutions.in sales@hvaccaresolutions.in THANK YOU