BMG Surveys Limited. Renewable Energy Consulting Engineering Services info@bmgsurveysltd.co.uk Tel: 0141 530 2322 © BMG Surveys Ltd 2014 Desk Top Structural Roof Appraisal Information Request Form Client Details Company Name: Company Ref/Project No: Justin Dring Hayfield Property Location Property Type Install Address Line 1 36 Install Address Line 2 Hayfield Rd Install Address Line 3 Salford Install Postcode: M68QA Nearest City/Town Salford Distance to the Sea (km) 48(km) http://www.daftlogic.com/projectsgoogle-maps-distance-calculator.htm Height Above Sea Level (m) 45(m) http://www.daftlogic.com/sandboxgoogle-maps-find-altitude.htm (Please use these links and provide the required information) 3 Storey Det/Terrace 2 Storey Det/Terrace Bungalow Garage X Barn Warehouse Industrial Unit School Other (Please specify) Approx. Age of the Property (Years) Property Information Roof Type: Pitched Curved X Property Size: See Ref A Building Length Building Width Roof Pitch Distance to the nearest Building Mono Pitch Hipped 6(m) 4(m) 30(Deg) 1(m) Flat Height to Eaves Height to Ridge Parapet Height (Flat roofs only) Height of nearest obstruction. (E.g. Higher Building o Tree) 6(m) 7.5(m) NA(m) 5(m) Approx. Where a building ridge line does not run through the middle of the building we would ask that you refer to Ref B and complete the section below Roof Pitch A (Deg) Roof Pitch B (Deg) Building Half Width A (m) Building Half Width B (m) Ref: A Ref: B BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH Tel: 0141 530 2322 Email: info@bmgsurveysltd.co.uk © BMG Surveys Ltd 2014. This document is the property of BMG Surveys Ltd. This document is protected. BMG Surveys Limited. Renewable Energy Consulting Engineering Services info@bmgsurveysltd.co.uk Tel: 0141 530 2322 © BMG Surveys Ltd 2014 Roof Information Roof Construction 1. 3. 6. Tile/Slate, Battons, Felt, Trusses/Rafters. Cement Fibre/Asbestos Sheets, Trusses/Rafters. Other: (Please specify) 2. 4. Trapezoidal Sheet, Insulation, Trusses/Rafter. (FLAT) Felt/Bitumen, Sarking, Truss/Roof Joists. 3. 5. Corrigated Metal Sheets, Trusses/Rafter. (FLAT) Trapezoidal Sheets, Truss/Roof Joist Trussed Roof Member Sizes Rafter Size: Web Size: Width Width 75(mm) 75(mm) Depth Depth 60(mm) 50(mm) Length Length 2400(mm) 2000(mm) Width Width (mm) (mm) Depth Depth (mm) (mm) Length Length (mm) (mm) Purlin Roof Member Sizes Purlin Size: Rafter Size: Flat Roof Member Sizes Roof Joist Size: Width (mm) Depth (mm) Length Span (mm) Span Between Intermediate Supports Please note that in order to complete the flat roof surveys all roof make-up information is required. BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH Tel: 0141 530 2322 Email: info@bmgsurveysltd.co.uk © BMG Surveys Ltd 2014. This document is the property of BMG Surveys Ltd. This document is protected. (mm) (mm) BMG Surveys Limited. Renewable Energy Consulting Engineering Services info@bmgsurveysltd.co.uk Tel: 0141 530 2322 © BMG Surveys Ltd 2014 BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH Tel: 0141 530 2322 Email: info@bmgsurveysltd.co.uk © BMG Surveys Ltd 2014. This document is the property of BMG Surveys Ltd. This document is protected. BMG Surveys Limited. Renewable Energy Consulting Engineering Services info@bmgsurveysltd.co.uk Tel: 0141 530 2322 © BMG Surveys Ltd 2014 Steel Frame Building Member Sizes Rafter Size: Width (mm) Depth (mm) Length Purlin Size: Width (mm) Depth (mm) Length Bracing Size: Width (mm) Depth (mm) Length Rafter Spacing C: (mm) Portal Frame Spacing D: Please provide diagram if unsure and include photos of internal construction. Single Bay Portal Frame (mm) (mm) (mm) Double Bay Portal Frame (Please provide width dimensions of each bay) Visual Roof Inspection by Client Are there any signs of deflection to the existing roof slopes? Are there any signs of rot/damage to the internal roof structure? Are there any signs of anything which would cause for concern when fitting panels to the roof? Are there any dwarf walls/props which support the purlins? Is there any signs of structural work which has been carried out to the roof structure before? Photograph Checklist North Elevation South Elevation Roof Trusses Rafter Steel Connections Roof Surface NO NO NO NO NO Panel Information East Elevation West Elevation Purlins Steel Sections Panel Diagram (incl. Dims) Panel Arrangement Diagram Panel Length Panel Width Panel Weight 1.6(m) .9(m) 22(kg) ONCE THE FORM IS COMPLETE PLEASE RETURN TO info@bmgsurveysltd.co.uk PLEASE ATTACH ALL OF THE REQUESTED PHOTOS AND A PANEL ARRANGEMENT DIAGRAM BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH Tel: 0141 530 2322 Email: info@bmgsurveysltd.co.uk © BMG Surveys Ltd 2014. This document is the property of BMG Surveys Ltd. This document is protected.