Desk Top Structural Roof Appraisal Information Request Form
Client Details
Company Name:
Company Ref/Project No:
Justin Dring
Hayfield
Property Location
Property Type
Install Address Line 1 36
Install Address Line 2 Hayfield Rd
Install Address Line 3 Salford
Install Postcode:
M68QA
Nearest City/Town
Salford
Distance to the Sea (km)
48(km)
http://www.daftlogic.com/projectsgoogle-maps-distance-calculator.htm
Height Above Sea Level (m)
45(m)
http://www.daftlogic.com/sandboxgoogle-maps-find-altitude.htm
(Please use these links and provide the required information)
3 Storey Det/Terrace
2 Storey Det/Terrace
Bungalow
Garage
X
Barn
Warehouse
Industrial Unit
School
Other (Please specify)
Approx. Age of the Property (Years)
Property Information
Roof Type:
Pitched
Curved
X
Property Size:
See Ref A
Building Length
Building Width
Roof Pitch
Distance to the nearest
Building
Mono Pitch
Hipped
6(m)
4(m)
30(Deg)
1(m)
Flat
Height to Eaves
Height to Ridge
Parapet Height (Flat roofs only)
Height of nearest obstruction.
(E.g. Higher Building o Tree)
6(m)
7.5(m)
NA(m)
5(m)
Approx.
Where a building ridge line does not run through the middle of the building we would ask that you refer
to Ref B and complete the section below
Roof Pitch A
(Deg)
Roof Pitch B
(Deg)
Building Half Width A
(m)
Building Half Width B
(m)
Ref: A
Ref: B
BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH
Tel: 0141 530 2322
Email: info@bmgsurveysltd.co.uk
© BMG Surveys Ltd 2014.
This document is the property of BMG Surveys Ltd.
This document is protected.
BMG Surveys Limited.
Renewable Energy Consulting Engineering Services
info@bmgsurveysltd.co.uk
Tel: 0141 530 2322
© BMG Surveys Ltd 2014
Roof Information
Roof Construction
1.
3.
6.
Tile/Slate, Battons, Felt,
Trusses/Rafters.
Cement Fibre/Asbestos
Sheets, Trusses/Rafters.
Other: (Please specify)
2.
4.
Trapezoidal Sheet,
Insulation, Trusses/Rafter.
(FLAT) Felt/Bitumen,
Sarking, Truss/Roof Joists.
3.
5.
Corrigated Metal Sheets,
Trusses/Rafter.
(FLAT) Trapezoidal
Sheets, Truss/Roof Joist
Trussed Roof Member Sizes
Rafter Size:
Web Size:
Width
Width
75(mm)
75(mm)
Depth
Depth
60(mm)
50(mm)
Length
Length
2400(mm)
2000(mm)
Width
Width
(mm)
(mm)
Depth
Depth
(mm)
(mm)
Length
Length
(mm)
(mm)
Purlin Roof Member Sizes
Purlin Size:
Rafter Size:
Flat Roof Member Sizes
Roof Joist Size:
Width
(mm) Depth
(mm) Length
Span
(mm) Span Between Intermediate Supports
Please note that in order to complete the flat roof surveys all roof make-up information is required.
BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH
Tel: 0141 530 2322
Email: info@bmgsurveysltd.co.uk
© BMG Surveys Ltd 2014.
This document is the property of BMG Surveys Ltd.
This document is protected.
(mm)
(mm)
BMG Surveys Limited.
Renewable Energy Consulting Engineering Services
info@bmgsurveysltd.co.uk
Tel: 0141 530 2322
© BMG Surveys Ltd 2014
BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH
Tel: 0141 530 2322
Email: info@bmgsurveysltd.co.uk
© BMG Surveys Ltd 2014.
This document is the property of BMG Surveys Ltd.
This document is protected.
BMG Surveys Limited.
Renewable Energy Consulting Engineering Services
info@bmgsurveysltd.co.uk
Tel: 0141 530 2322
© BMG Surveys Ltd 2014
Steel Frame Building Member Sizes
Rafter Size:
Width
(mm) Depth
(mm) Length
Purlin Size:
Width
(mm) Depth
(mm) Length
Bracing Size:
Width
(mm) Depth
(mm) Length
Rafter Spacing C:
(mm)
Portal Frame Spacing D:
Please provide diagram if unsure and include photos of internal construction.
Single Bay Portal Frame
(mm)
(mm)
(mm)
Double Bay Portal Frame
(Please provide width dimensions of each bay)
Visual Roof Inspection by Client
Are there any signs of deflection to the existing roof slopes?
Are there any signs of rot/damage to the internal roof structure?
Are there any signs of anything which would cause for concern when fitting panels to the roof?
Are there any dwarf walls/props which support the purlins?
Is there any signs of structural work which has been carried out to the roof structure before?
Photograph Checklist
North Elevation
South Elevation
Roof Trusses
Rafter
Steel Connections
Roof Surface
NO
NO
NO
NO
NO
Panel Information
East Elevation
West Elevation
Purlins
Steel Sections
Panel Diagram (incl. Dims)
Panel Arrangement Diagram
Panel Length
Panel Width
Panel Weight
1.6(m)
.9(m)
22(kg)
ONCE THE FORM IS COMPLETE PLEASE RETURN TO
info@bmgsurveysltd.co.uk
PLEASE ATTACH ALL OF THE REQUESTED PHOTOS AND A PANEL ARRANGEMENT DIAGRAM
BMG Surveys Ltd. registered in Scotland. Registered no. SC408887. Registered office – 34 Cortmalaw Gate, Glasgow, G33 1TH
Tel: 0141 530 2322
Email: info@bmgsurveysltd.co.uk
© BMG Surveys Ltd 2014.
This document is the property of BMG Surveys Ltd.
This document is protected.
Download