INDIA belive Power From Sun + Battery(HESB) Green Power/Silent Power/Econmical Power Sabco Bijlee Milegi Hum Dekarke Rahenge Presentation on Best Practice for Electrical Equipment Installation and Safety of Product(Earthing & Protection) Electric Power Systems Lets us work till dark is away from Each Home Battery Power Generation Transmission Consumption M G Generation Distribution Transmission Distribution Load Renewable power Microgrid control system Energy storage and grid stabilization Easy to generate power as our Choice An Arcing Fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground. Concentrated radiant energy is released at the point of arcing an a small amount of time resulting in Extremely High Temperature. Fire Accident in Solar PV Power Plant Reason Lose Contact Earthing Disorder and Lightning Solar Panel Fire Accident More Picture Fire in Solar Pv Power Plant More Picture • • • • • • • • • India Plan 100GW Solar Power in Year 2022 Solar Power Now Changing Many Phases Use with Genset Use with Wind Power Use with High Energy Storage(Battery) Instalation on Ground/Cannel Mounted Instalation on Roof (Building) Instalation on Water (Floating) Instaltion on Building(BIPV Building Integrated Transparent Photovoltaic Solar Glass My Gudget My Confidence My Safety Surge Protection use Recommendation We are offering Surge Protection Devices as IS/IEC 62305-4 v External/Internal Surge Source Horrifying Losses Due To Devil Lightning India Life can be Save from Lightning Sikhana to Padega Hi Follow NBC2016 Surge in Systems and Result Surge in DC Application Earthing Design and Require Result • For substation Large Power below 1.00Ohm • For substation Small Power below 2.00Ohm • SCADA/TELECOM and AutomationFor substation Large Power below 0.50Ohm • Tower and Other Structure between 8-15Ohm • Lightning Surge Protection 50KA below 5Ohm or 100KA between 8-15Ohm • Follow Standard IEC /IEEE • Recommended use of Hybrid Metal to Protect from Theft Copper Clad Steel/Alumineum Clad Copper • Exothermeic weld IEEE 837 Maintenance Free - Equipment Earthing 33KV Electrical Sub Station Grid/Earth Mat Design JMV LPS Products Copper Cladded Conductor For Electrical Installation The Copper Clad Steel Grounding Conductor is made up of steel with the coating of 99.99% pure copper. These conductors/ wires or strands are equipped with the strength of steel with the conductivity and copper with the better corrosion resistance property. The concentric copper cladding is metallurgic ally bonded to a steel core through a continuous, solid cladding process using pressure rolling for primary bonding. The copper cladding thickness remains constant surrounding steel. We use different steel grades for the steel core result in Dead Soft Annealed, High strength and Extra High Strength Characteristics. The Copper Clad Steel Wire yields a composite conductivity of 21%, 30% and 40% IACS, and available in Annealed and Hard drawn. We are delivering products with varied conductivity and tensile strength as per the customer need. Further, the wire can be processed to be silver plated or tinned copper clad steel wire. Most Efficient Joint Process/Fail Proof It is efficient and superior to all existing surface –to-surface mechanical retention connectors. What is Exothermic Welding System Copper to Bi-Metal and Alumenium Types of Exothermic Joints: Possible to join any bi metal except aluminum Exothermic welding is a process of making maintain free highly molecular bonding process is superior in performance connection to any known mechanical or compression-type surface-to-surface contact connector. Exothermic weld connections provide current carrying (fusing) capacity equal to that of the conductor and will not deteriorate with age. It offers Electrical connections between two or more copper to copper and copper to steel conductors. Highly portable method as it does not require any external power source or heat source, so it can be done almost anywhere. It provides strong permanent molecular bond among metallic conductors that cannot loosen and further will not deteriorate with age. Connection does not corrode with time and it offers permanent conductivity. Copper Clad Steel Solid ROD and Conductor LIGHTNING FORMATION Facts about Lightning • A strike can average 100 million volts of electricity • Current of up to 200,000 amperes • Can generate 54,000 oF • 10/350MicroSec/50KA Fault Current/Discharge in Nano Sec Protection Earthing Design100KA Fault Current/Joints Exothermic /Flexible Down Conductor with Shortest Route & Less Corner • Lightning Protection Standard use in India (IS2309 Now IEC 62305-5)NBC2016 Working Principle Angullar No Compromise with Design Max Protection 30Mtrs from One No Product warrenty from Manufacturer High Maintenance Require Earthing below 10.00 Ohm Lightning Risk assessment Study is actually the measure of risk of a lightning strike and probability of damages. As Per IEC62305-2. All these calculations are based on: Lightning strike density inthat particular area(provided byOMV i.e.Ng = 8), Danger for people, Occupation coefficient of structure, Relative location of site, Fire Risk, Associated services, Electrical Lines, Lightning Protection Level, Surge Arrestor and Dimensions of installation. Risk Assessment Calculator as per IS/IEC 62305 Standards Worldwide for Lightning NFC17-102 and IEC62305-3 Air- Termination System 1. Vertical Rods- simple shaped buildings 2. Catenary wiressuitable for all cases 3. Meshed/ Grid Conductors- best for where plane/ pitch roof surfaces Lightning Protection As Per NF C 17 102/UNE 211186 The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures. The generated protection radius depends on the early streamer emission value of the air terminal (Δt in µs), its height, and the efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60 m , early streamer emission time 60µs). The NFC 17-102/UNE 211186 standard describes the installation procedure for this type of air terminal. The installation of this type of air terminal is easy and cheaper than other technologies. It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration. 1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection. The Simple Rod air terminal is composed from a metallic rod with 2 to 8 m height dominating the structure to protect, and linked to 2 down conductors minimum, and 2 earthing systems. The protection radius ensured by this air terminal which is limited to 30 m more or less (Protection level IV, height = 60 m), especially dedicated to the protection of small structures or areas like towers, chi eys, ta ks, water tower, a te a asts… The EN 0 -3 standard describes the installation procedure for these air terminals. 13 Simple Rods, 13 down conductors, and 13 earthing systems are necessary to ensure the protection below : IEC Declaration by CENELEC for NFC17-102 BT has confirmed that ESE National Standards would remain valid and thus BT recognized there ould e o e ide e of o fli t et ee NF C ‐ a d IEC EN ‐ sta dards a d consequently there is no reason, technical or otherwise, for the withdrawal of the respective national standard.BT has requested that this standard be modified in order to cancel all refere e to the IEC EN ‐ series, allowing the NF C ‐ sta dard to e ist, ith the proposal of possible future migration to international level (lEC). Accordingly, it was established that European ESE standards (France, Spain, Portugal, Slovaquia, etc.) will not conflict with other European standards and will remain valid. • GIMELEC would draw your attention to the fact that the ter s of refere e of NF C ‐ a d • other standards, addressing alternative terminals (NF C ‐ , PR EN ‐ ‐ ere fro the • outset, er differe t. It is a fa t that NF C ‐ , whilst referring to ESE Technology also • comments on other standards for lightning protection systems, particularly incorporating • faraday cage, franklin rod and catenary wire systems. the 'camouflaging' of NF C ‐102 by IEC EN • ‐ and its proponents, that FRENCH STANDARD NF C ‐ is still in full force. The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures. The ge erated prote tio radius depe ds o the earl strea er e issio alue of the air ter i al Δt i µs , its height, and the efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60 m , early streamer emission time 60µs) The NFC 17-102 standard describes the installation procedure for this type of air terminal. The installation of this type of air terminal is easy and cheaper than other technologies. It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration. 1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection below : •An active and advance technology device based on the principle of Corona effect. •Internationally accepted technology complying standard NFC 17-102. •Active Protection not only protects the structure also protect surroundings & open areas. •Made up of stainless steel SS-316L hence highly corrosion resistant and long lasting. •More life due to corrosion resistant material is used. •Single installation offering maximum radius of protection of 109 meters which is very large in comparison to conventional lightning system. •ESE air terminal is very quick in response. •Excellent, no electronic device. •Economical solution. •Easy to Install. ESE Installation Guidence ESE AT with radius protection form 32 mtr to 107 mtr. DMC Insulator . GI/FRP Mast . Down Conductor Copper / Copper Cadmium Cable 70 sq. mm Copper Bonded Ground Earthing Thimble Joint all phase wire/ cable with the help of crimping tools and lugs Step – 1 Separation Sheet Fixed the separation sheet between all wires/ cables Step – 2 Gel / Silicon Close the filled Silicon enclosure from top and bottom , complete installation is done. Step – 3 Features : Provides cable with cable connections and jointing wires in switchboard / electric boxes Being a jelly it can be easily fit into molds of any shape and size. Helps in safeguarding electrical connections and also protects electrical connection joints from catching fire, sparking and leakage current. Eradicates all the possibilities of fire, electric shocks and sparks, etc. causes due to improper electrical connection joints and safeguards structure, equipment and person. Offers safety to your electrical joints from ageing, corrosion, moisture and also observes leakage current. Advantages : Nontoxic Insulating Highly reliable operation Maintenance Free Repairable Cost Effective High repeat value Elasticity Shape retention JMV’s Clients Contact Professionals for Advise We Protect You Use Electrical Safety Earthing & Protection Contact our Team JMV INDIA Leader and Insperation behind Mr.Neeraj Saini neeraj@jmv.co.in Mr.Mahesh Chandra Manav Brand JMV HOD manav@jmv.co.in www.jmv.co.in Moblie -919910398999 Telecom -9191204590000