DO NOT SCALE THIS DRAWING . USE FIGURED DIMENSIONS THIS DRAWING IS COPYRIGHT. DO NOT REPRODUCE IT WITHOUT WRITTEN PERMISSION VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR SHOP DRAWINGS INFORM THE ARCHITECTS BEFORE ANY WORK STARTS IF THIS DRAWING EXCEEDS THE QUANTITIES IN ANY WAY Section F Notes: Face of external wall below 1:80 fall Cavity tray Weepholes 25mm perimeter continuous air gap (shown in hatch) serving 50mm air gap above rafters air Eaves +26.300 air gap air W5 05 air Level 5 FFL+25.337 air reconstituted stone Top of Roof +26.320 +26.490 100 lead fascia air Top of Flashing & Airtrak +25.810 air air Nicholson Airtrak AB Nicholson CL Ventilator +25.585 +25.485 air 1:80 fall air Top of Nicholson CL Ventilator to Lift Overun +25.750 air +25.470 +25.415 +25.595 air +25.400 1:80 fall air air 310 tier 100mm dia.rwp from main roof C7 200x8SHS 1:80 fall 1:80 fall +25.250 1:80 fall +25.240 1:80 fall Wood cored rolls Sect E B Top of Coping +26.565 150 237 236 235 234 233 232 231 230 229 228 227 226 Lift Overrun Roof 1:80 fall Sect D 241 240 239 238 Horiz Sect A lead welt air gap air Wood cored rolls 1:80 fall 3 B All lead details to Lead Sheet Association recommendations to be found in The Rolled Sheet: The Complete Manual and online at www.leadsheet.co.uk Refer also to B&B Structures drawings Refer also to B&B M&E/Public Health drawings Refer also to Onsite Services Fabrication drawings All openings for ventilation into internal wall and roof voids to be sealed with insect mesh All timber to roofs and external walls to be treated. Code 5 Lead Flashing at junction lift overun outcrop and perimeter wall All leadwork shown in dotted hatch on elevations 126 air 100mm dia.rwp from main roof W5 05 75 A Top of Roof +26.320 lead welt 3180 lead welt A Section G 100 3 3x100mm Rockwool Flexi Continuous vapour control layer, above suspended ceiling 2x100mm Rockwool Flexi Lobby 238 copings 237 cavity tray 236 235 weepholes 234 233 232 231 55mm Cellotex inuslation to 230 section of cavity wall 229 enclosing lift shaft. Note: not required where wall external 228 on both sides 227 226 Lintel over 225 x225 225 opening in both cavity wall 224 leaves to Structural 223 Engineer's details 222 +25.215 221 220 219 Code 5 lead drip into Alumasc Cast Iron hopper 218 and downpipe 217 216 Code 5 lead flanks, on 215 building paper on 21mm wpb ply substrate to brick 214 opening to hopper 213 21mm wpb ply on mortar 212 bed on slate closer to head 211 of cavity wall 210 209 208 B&B Structures Fixing details: Joist hangers for the timber joist for the lift roof to be fixed to the RHS beams section by shot fired ( We recommend that 4 Hilti 12mm X-EDNI steel pins are fired into a steel). Joist hangers can also be screwed to the steel (Minimum 4 self drill / tap screws required. Minimum recommended diameter 5.5mm.) All 225x47 joists to be Grade C24 Key: Blockwork Smeed Dean Stock Brickwork 55mm Cellotex CW4000 100mm Rockwool Flexi insulation Vapour control layer below internal face Section E Horizontal Section A APPROVAL OF DETAILS RESERVED BY CONDITION 13b. B Note: Code 6 lead to main roof. Code 5 to lift overun outcrop and its roof, and to all flashings, internal lead lined gully and sump (Ref: PP/13/00230 Area highlighted in drawing: 1179-155B) A Code 5 Lead Flashing at junction lift overun outcrop and perimeter wall 25 100 +26.020 50 air Nicolson Airtrak AB Level 5 FFL+25.337 air 3X100mm Rockwool Flexi Overun roof 47x170mm Grade C16 treated and regularised softwood rafters at 300mm c/c with noggins as reqd. All timber joists requiring fixing to steelwork, to be Tek screwed to steelwork, via joist hangers were required Top of Steels +25.195 2x 12.5mm Fermacell lining to internal surfaces of Lift shaft and riser above this level 2no.47x225mm joists below stud wall above Blockwork and head details tbc Note to joists, rafters. Tek screw through hangers as fixing to steelwork where required Riser Lift Shaft 55mm Cellotex insulation to section of cavity wall enclosing lift shaft. 238 237 236 +26.490 235 weepholes 234 233 232 231 cavity tray 230 229 228 weepholes 227 Nicholson Airtrak AB to length of wall 226 25 225 224 55mm Cellotex insulation 223 taken up to top of lead 222 flashing 221 220 219 218 217 216 215 214 213 212 211 210 310 209 208 207 206 205 Section F Section D Eaves +26.300 Top of Roof +26.320 fall 1:80 open to air at side eaves U/S Cill +25.975 airgap 25 insect mesh continously over gaps 300 air 210 Top of Flashing & Airtrak +25.825 weepholes air 21 +25.585 fall 1:80 air +25.595 Top of 100mm Rockwool Flexi to flank walls and roof to lift overrun. Maintain 50mm clear air gap on external face 25 50 100 Stud external wall of treated 100x50mm CLS studs at 300mm c/c with, 100X50mm sole and head plates. Noggins as required 1262 C/L to C/C airgap air 3X100mm Rockwool Flexi MF ceiling 2x225X47mm joists below stud wall above cut into web of steel on gridline 3 Shaftwall tbc Typical ceiling construction: -100mm Isover APR 1200 sound insulation -16mm RB1 Resilient bars at 450c/c - Continuous vapour control layer -19mm Gyproc Plank -12.5mm Soundbloc Lobby -Skim coat air +25.825 Flashing & Airtrak Top of lead flashing behind/ u/s cavity tray weepholes fall 1:80 air 150 reconstituted stone copings cavity tray 50 airgap reconstituted stone copings cavity tray continuous below copings weepholes 246 50mm continuous airgap 238 237 236 235 234 233 232 231 230 229 228 227 226 225 224 223 222 221 220 219 218 217 216 215 214 213 212 211 210 209 208 207 206 205 Highpoint of Low Roof +25.570 Fermacell and treated timber stud enclosure Top of Shaftwall 3510mm above L4 FFL Code 5 lead flashing Top of Beam +26.210 +26.490 Code 5 lead flashing 25 dpc cavity tray weepholes Top of Roof +26.320 W5 05 Top of Coping +26.565 150 cavity tray weepholes Top of Steel c4 +26.280 50 237 236 235 234 233 232 231 230 229 228 air 227 226 Insect mesh to perimeter eaves openings 50 241 240 239 238 Code 5 Lead Flashing at top of lift overun roof, dressed in under coping. Mastic sealant cover. Top of Coping +26.565 280 Horiz Sect A clear to low point of interior dimension W5 05 Note to joists, rafters. Tek screw through hangers as fixing to steelwork where required 310 Lift Shaft 241 240 239 238 237 236 235 234 233 232 231 230 229 228 227 226 225 224 223 222 221 220 219 218 217 216 215 214 213 212 211 210 209 208 207 206 205 Type F reconstituted stone copings cavity tray weepholes B 16.04.14 pm A 14.04.14 pm Rev.No. Date By Crossbeams highlighted as bubbled, B&B Structures information added Comments added. Cavity tray/weephole notes. Issued for Construction WELDON WALSHE ARCHITECTURE . INTERIOR DESIGN . HISTORIC BUILDING CONSERVATION 20 GROSVENOR PLACE LONDON SW1X 7HN t:0044 207 235 4100 f:0044 207 235 6678 17 Cadogan Place London SW1X 9SA Rear Wing Roof and Lift Overrun DISCHARGE OF PLANNING CONDITIONS scale: 1:20@a1, 1:40@A3 date: 07/04/14 dwg no: 0 3 4 5M Amendment drawn by: pm rev: 1179 537 B