INSTALLATION INSTRUCTIONS HYPAK 3000/HP3 MOUNTING CODE SURFACE SNB - (OVER 4-0 BOX) SDE - (DIRECT ENTRY) SSB - (WITH SPLICE BOX) Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. INSTALLATION DIAGRAM Integral knockouts (2) are provided for independant mounting of housing. Knockouts accept 1/4” anchor bolts (bolts by others). For surface direct entry (code 2) Hydrel provides two 1/2” NPT openings for conduit connection. For surfacemounting over 40 box (code 1) remove cast knockouts provided in housings, mount fixture over box, and connect supply wires. For surfaces with splic box (code 3) openings are 3/4”,NPT - three places INSTALLATION DIAGRAM RECESSED For recessed direct entry (code 4) connect 1/2” conduit to housing and pour concrete. Wireway cover in housing provides splice compartment. SNB - (OVER 4-0 BOX) RDE - (DIRECT ENTRY) RSB - (WITH SPLICE BOX) Recessed units with splice box (code 5) are provided with three 3/4” NPT openings. INSTALLATION DIAGRAM BASE BMS Base (code 6) or pendant (code 8) bracket affixes to mounting bracket with four 1/4-20 set screws. PENDANT Mounting bracket provided is affixed over flush 4-0 ox (box by others) by 5/16” bolts (bolts by others). SPM ©2009 Hydrel Rev. 06/10/09 INS-HP3 REV_0 NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973) 20660 Nordhoff St., Suite B Chatsworth, CA 91311 Phone: 866.533.9901 Fax: 866.533.5291 www.hydrel.com HYPAK 3000/HP3 Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. INSTALLATION DIAGRAM PLASTER FRAME PFD - (DIRECT ENTRY) To mount plaster frame properly, orient as shown. PFS - (WITH SPLICE BOX) Attach fixture to frame as shown using knockouts provided for hole location (2) Affix 4-0 box to back of fixture. (code 13) (box by others) Two 1/2" NPT openings are provided for direct entry into fixture (code 12) Studs Drywall Stud around plaster frame as shown. Affix frame to studs through 14 dia. holes provided. Housing fits into frame as shown. Align frame screws with cast in knockouts. Reflector affixes to housing by two 10-24 screws. Direction of light distribution For asymmetrical distributions (HP3G & HP3H) plaster frame orientation is key. Orient frame as shown to aim distribution as desired. ©2009 Hydrel Rev. 06/10/09 INS-HP3 REV_0 NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973) 20660 Nordhoff St., Suite B Chatsworth, CA 91311 Phone: 866.533.9901 Fax: 866.533.5291 www.hydrel.com