Project: Type: Catalog #: Model SI-L-A Small Inverter 240W, 350W, 500W, 1000W, 1500W, or 2000W FEATURES - No individual battery packs to replace means lower maintenance costs, quicker testing, and greatly reduced electronic waste - only batteries need to be replaced, not entire battery packs with electronics. - High effiency, pure sine-wave inverter delivers full output throughout 90 minute operation. - Automatic diagnostics for connected loads through patented RLS. Every day testing alerts room occupants and custodians of problems with tubes, ballasts. When room switch is turned off emergency lights stay on for 2.5 seconds to ensure compliance with NFPA 101 and eliminate lengthy and costly monthly testing procedures, which, in some districts, requires fire marshal supervision. The SI-L-A is housed in a custom, powder coated, metal panel engineered for strength, but still lightweight to reduce shipping charges and allow easy, single person handling and installation. All individual parts weigh less than 50 lbs. - Innovative battery harness with disconnects makes installation and servicing safe and easy. No factory startup required. Modular Design - All major components are field replaceable. Provides line voltage to any load you specify, compatible with fluorescent, incandescent, LED, halogen, and CFL loads. Designated emergency fixtures will operate at full brightness, eliminating tedious calculations and guesswork. - Visible LED indicators supervise input, output, and charging circuits (2 LED’s) Self resetting protection for overload, reverse polarity, shorts, temperature-controlled fan and more. Designed for 25 year trouble-free operation Full 3 year warranty on electronic components 6 year pro-rata warranty on batteries UL924 Listed Emergency fixtures operate at full output (2800 lumen for F32T8) during power failure for 90 minutes Standard Battery Packs provide only 600-100 lumens per tube Regular Room Designated Fixtures Emergency Fixtures Up to 2000W of Fluorescent, Incandescent, LED, Halogen, and CFL Loads CATALOG # SI-L-A-240W-120V SI-L-A-240W-277V SI-L-A-350W-120V SI-L-A-350W-277V SI-L-A-500W-120V SI-L-A-500W-277V SI-L-A-1000W-120V SI-L-A-1000W-277V SI-L-A-1500W-120V SI-L-A-1500W-277V SI-L-A-2000W-120V SI-L-A-2000W-277V Regular Lighting Circuit 120V or 277V Utility Input Regular Room Designated Fixtures Emergency Fixtures Regular Lighting Circuit RLS Control 120V or 277V Emergency Output Dedicated 20 Amp Circuit Utility Power Unit SI-L-A RLS Control [To additional rooms] Transfer Control Charger Emergency Output RL1 RL2 Batteries Charger LED Inverter Fuse Utility Power Supervision & Test Utility Power LED OPTIONS 208V - 208V EELP • 2577 Neshaminy Interplex Drive - KOR A, Suite 102 - Trevose, PA 19053 • Phone: 800-490-4496 • Fax: 877-634-6887 • www.eelp.net SI-L-A 08082016 NORMAL OPERATION -- The SI-L-A Transfer Control will feed Utility Power through RL1 (see diagram). This will supply all emergency loads connected to the SIL-A. -- Supervisory LED’s will indicate that utility feed, inverter, and charger are all energized and operating properly. -- Test switch is easily accessible without opening cover and may be pressed to switch SI-L-A to emergency mode. TRANSFER - Upon power failure the SI-L-A will transfer from utility power to inverter power through relays RL1 and RL2 (see diagram). - These relays are electronically interlocked with a time delay, which prevents arcing when transfering between two out of phase power sources. This safety feature protects the SI-L-A, loads, as well as expensive equipment on both sides of the inverter. EMERGENCY OPERATION - The SI-L-A Transfer Control will feed pure sine wave Inverter Power through RL2 (see above). This will supply all emergency loads connected to the SI-L-A for up to 90 minutes. - Optional RLS emergency lighting controls in each room allow emergency fixtures to be controlled from regular wall switches, occupancy sensors, or dimmers during normal operation, but will automatically illuminate emergency fixtures at full brightness during emergency operation. SAFE GUARDS AND SPECIAL FEATURES - Self-resetting overload protection and fused output - 120VAC or 277VAC Pure Sine Wave Output 2000W, 1500W, 1000W, 500W, 350W, or 240W load for 90 minutes - Automatic Output Voltage Tracking maintains output voltage at full load ± 3% - Operates fluorescents, dimmable fluorescent ballasts, CFL, LED, halogen & incandescent loads. - Distortion (THD): Less than ± 3% - EMI in compliance with FCC Class A Regulation - Test switch to simulate utility power loss. - Efficiency: 99% at Full Load - Sealed Lead Calcium batteries provide long life and are maintenance free. - 3/6 Warranty (3 year replacement warranty on electronics, 6 year pro-rata warranty on batteries) - Small footprint: 2000W Model: 25” (L) x 28“ (H) x 12.5” (D) 1500W Model: 25” (L) x 28“ (H) x 12.5” (D) 1000W Model: 25” (L) x 17“ (H) x 12.5” (D) 500W Model: 25" (L) x 17" (H) x 12.5" (D) 350W / 240W Models: 27.5” (L) x 9” (H) x 7.5” (D) - Thermostat Controlled Silent Cooling Fan - Load Power Factor: 0.9 leading to 0.9 lagging - 1.5 seconds transfer time to protect against momentary ON/OFF voltage surges caused by power line hitting wet pavement or other power lines during a storm. - Operating Temperature: 40°F to 100°F - Frequency Regulation: ± 5% - 10W Input power (2000W) or 5W Input Power Consumption (all other models) when batteries are fully charged. - Automatic low voltage battery disconnect, deep discharge protection, over-temperature shut down, and reverse polarity protection. - Automatic Emergency Fixture Diagnostics when used in conjunction with EPC-A-1 to eliminate monthly test of emergency fixtures. - GFCI Protection for 120V models SI-L-A-240W SI-L-A-350W SI-L-A-1000W SI-L-A-1500W SI-L-A-2000W Status LED Indicators 120VAC Utility Power On 120VAC Inverter On Test Switch