Spec Sheet - E

advertisement
6” VERTICAL LAMP COMPACT FLUORESCENT
NEW CONSTRUCTION - TYPE NON-IC
(E-RFN632UTP)
Applications: For use in non-insulated ceilings or where insulation can be kept 3” from housing.
7.5"
(191mm)
6.313"
(160mm)
•
•
•
•
•
•
•
•
Catalog #
Ceiling
Cut-Out
Plaster
Frame
E-RFN632UTP
6-3/8"
7-1/8"W X 10-3/8" L
Construction & Materials
Lamp
(Ordered Separately)
Junction Box is listed for eight (4in – 4out) No. 12AWG (90˚C)
through-branch circuit conductors and has five 1/2”, one 3/4” and
four Romex® knockouts with true pry out slots.
Romex knockouts include built in strain relief – no additional clamps required.
Pre-installed hanger bars allow housing to be positioned at any point
within 24” joist span. Score lines provided for easy field shortening to
accommodate 12” joist span.
Hanger bars are designed to fit on to T-Bar spine for quick alignment and
can be permanently secured without the need for additional clips.
Hanger bars can easily be field repositioned 90˚ on the plaster frame
Housing adjusts for ceilings up to 1-3/8” thick.
7-1/2” height allows for use in 2” x 8” joist construction.
Adjustable socket bracket allows the use of different lamp types
and sizes as well as proper and consistent lamp positioning
Trims
• E-T6200CL - Clear reflector
• E-T6300WH - Full Cone White Metal Baffle
• E-T6400BK - Black Metal Baffle w/Reflector
(1) 26W or 32W Double
or Triple-Tube CFL
Lamp Base
Ballast
Minimum
Starting
Temp.
4-pin GX24q-3
120V - 277V
Electronic HPF Ballast
-18˚C (0˚F)­­­
Performance
• 2-year limited warranty
Electrical
• Thermally protected, fused, Universal voltage (120V through 277V)
electronic ballast with end-of-lamp-life protection (26W or 32W)
Regulatory
• UL, cUL listed for use in damp locations
• UL, cUL wet locations listed with select trims
• E-T6400WH - White Metal Baffle w/Reflector
• E-T6510WH - Fresnal Glass Lens w/Reflector
• E-T6511WH - Albalite Glass Lens w/Reflector
• E-T6513WH - Drop Opal Glass Lens w/Reflector
• E-T6550WH - Fresnal Glass Lens
• E-T6552WH - Albalite Glass Lens
• E-T6556WH - Drop Opal Glass Lens
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
6” VERTICAL LAMP COMPACT FLUORESCENT
NEW CONSTRUCTION - TYPE NON-IC
(E-RFN632UTP)
Albalite Glass Lens w/Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• Wet Location Listed
• O.D. 8"
Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• O.D. 7-9/16"
CAT.# E-T6200CL
CAT.# E-T6511WH
Full Cone White Metal Baffle
• White Self Flanged Baffle
• O.D. 7-9/16"
CAT.# E-T6300WH
Drop Opal Glass Lens w/Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• Wet Location Listed
• O.D. 8"
CAT.# E-T6513WH
Black Metal Baffle with Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• O.D. 7-9/16"
Fresnel Glass Lens
• White Metal Trim Ring
• Wet Location Listed
• O.D. 7-3/4"
White Metal Baffle with Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• O.D. 7-9/16"
Albalite Glass Lens
• White Metal Trim Ring
• Wet Location Listed
• O.D. 7-3/4"
Fresnel Glass Lens w/Reflector
• Specular Clear Reflector
• White Plastic Trim Ring
• Wet Location Listed
• O.D. 8"
Drop Opal Glass Lens
• White Metal Trim Ring
• Wet Location Listed
• O.D. 7-3/4"
CAT.# E-T6400BK
CAT.# E-T6400WH
CAT.# E-T6510WH
CAT.# E-T6550WH
CAT.# E-T6552WH
CAT.# E-T6556WH
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
Download