Cerro LED IMPORTANT SAFEGUARDS a) READ AND FOLLOW ALL SAFETY INSTRUCTIONS b) Do not use outdoors. c) Do not mount near gas or electric heaters. d) E quipment should be mounted in locations and at heights where it will not readily be subjectd to tampering by unauthorized personnel. e) T he use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. f) Do not use this equipment for other than intended use. g) Transfer switch for UL924 applications supplied by others. h) For UL924 applications maximum installation height is 40ft. SAVE THESE INSTRUCTIONS Installation Instructions: Surface Mount (F) Tools Required (not included): Phillips Screw Driver Junction Box Adaptor Plate Junction Box and (2-4) Mounting Screws (supplied by others) Luminaire Driver Box Assembly Center Support Ring Figure A 1. Mount junction box flush with ceiling or wall surface. 2. Install (2-4) mounting screws into junction box (leave loose approximately 1/8”). 3. Connect feed wires from Luminaire into junction box. 4. Remove center support ring per Figure A. 5. L oosen, but do not remove, (2) screws and drop Driver Box Assembly. 6. Install fixture flush to wall while inserting junction box mounting bolts into Adaptor Plate key holes. 7. Twist fixture clockwise to lock bolts into slots and tighten (2-4) junction box mounting bolts (accessing through the center of the fixture). 8. Reinstall driver box assembly and tighten (2) mounting bolts. 9. Install options per Figure B. 10. Reinstall center support ring per Figure C. Figure C Figure B Luminaire Collector Lens (CL) Option Spacer Ring (W) Option Opal Glass Diffuser (GD) Option CLICK! Perforated Center Plate (PC) Option Solid Center Plate Center Ring Page 1 of 3 (Rev. 09/15) CERL_INST_v2.0 Cerro LED Installation Instructions: Rigid Stem (RS) and Swivel Stem (S) Tools Required (not included): Phillips Screw Driver Junction Box and (2)Mounting Screws (supplied by others) Mounting Nut Spanner Bar Canopy Grounding Bolt 1/4” Stem Luminaire 1. Remove center support ring per Figure A. 2. Install options per Figure B. 3. Reinstall center support ring per Figure C. 4. Mount Spanner Bar on Junction box with (2) mounting screws. 5. R oute feed wires through Stem and screw Stem into Bushing on Luminaire. 6.Route Stem through Canopy and Spanner Bar and secure with Mounting Nut. 7. Connect feed wires from Luminaire into Junction Box and connect Grounding Bolt. 8. M ove Canopy flush with ceiling or Junction Box and tighten set screw. 1/4” Stem Stem Mount Bushing Figure A Figure C Figure B Luminaire Collector Lens (CL) Option Spacer Ring (W) Option Opal Glass Diffuser (GD) Option CLICK! Perforated Center Plate (PC) Option Solid Center Plate Center Ring CAUTION DANGER LED Radiation. Hazardous voltage. Do not operate while LEDs are exposed. Only work on de-engergized equipment. Disconnect power before wiring fixture. Do NOT stare into Beam. Can cause eye damage. Contact will cause electric shock or burn. Selux Corporation © 2015, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us Please Note: Disconnect electricity to fixture before working. To be performed by trained personnel only. It is the responsibility of the installer to ensure all electrical, mechanical, and thermal compatibility of the installation site and luminaires prior to installation. Please observe all relevant building codes and regulations. Keep these instructions after unpacking fixture. For indoor use only. For detailed spec sheets and more information on this and our full range of products, please visit our website at selux.us. Warranty information: http://www.selux.us/en/resources/terms-and-warranty.html NOTICE Do not touch LED May damage device Observe precautions for handling electrostatic sensitive devices. Page 2 of 3 (Rev. 09/15) CERL_INST_v2.0 Cerro LED Installation Instructions: Cable (C) Tools Required (not included): Phillips Screw Driver Junction Box and (2)Mounting Screws (supplied by others) Mounting Plate Canopy Ground Screw (3) Cable Coupler Power Cord and (2) Strain Reliefs (3) Suspension Cables (3) Cable Grip Luminaire 1. Remove center support ring per Figure A. 2. Install options per Figure B. 3. Reinstall center support ring per Figure C. 4. Screw (3) Cable Grips into back plate of Luminaire. 5. W ire Power Cord into Luminaire and connect (1) Strain Relief into Luminaire. 6. Install Mounting Plate onto Junction Box with (2) mounting screws. 7. Connect Power Cord into Junction Box through Canopy and Mounting Plate. Connect Grounding Bolt. 8. C onnect (1) Strain Relief into Canopy and push Canopy flush with ceiling or Junction Box. 9. Screw (3) Cable Couplers into Mounting Plate through the Canopy. (3) Cable Grip Luminaire Figure A Figure C Figure B Luminaire Collector Lens (CL) Option Spacer Ring (W) Option Opal Glass Diffuser (GD) Option CLICK! Perforated Center Plate (PC) Option Solid Center Plate Center Ring CAUTION DANGER LED Radiation. Hazardous voltage. Do not operate while LEDs are exposed. Only work on de-engergized equipment. Disconnect power before wiring fixture. Do NOT stare into Beam. Can cause eye damage. Contact will cause electric shock or burn. Selux Corporation © 2015, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us Please Note: Disconnect electricity to fixture before working. To be performed by trained personnel only. It is the responsibility of the installer to ensure all electrical, mechanical, and thermal compatibility of the installation site and luminaires prior to installation. Please observe all relevant building codes and regulations. Keep these instructions after unpacking fixture. For indoor use only. For detailed spec sheets and more information on this and our full range of products, please visit our website at selux.us. Warranty information: http://www.selux.us/en/resources/terms-and-warranty.html NOTICE Do not touch LED May damage device Observe precautions for handling electrostatic sensitive devices. Page 3 of 3 (Rev. 09/15) CERL_INST_v2.0