John W. Riner, P.E. Florida License #66867 SEAL ELECTRICAL SYMBOL LEGEND THREE-WAY SWITCH S4 FOUR-WAY SWITCH BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, UNDERGROUND OR UNDER FLOOR. SP SINGLE POLE SWITCH WITH PILOT LIGHT BRANCH CIRCUIT CONDUIT EXPOSED SWP SINGLE POLE SWITCH WITH WEATHERPROOF COVER SINGLE POLE SWITCH WITH WEATHERPROOF LOCKING COVER SK SINGLE POLE KEY SWITCH S3K M MOTION DETECTOR 360° CR CARD READER K DIGITAL KEYPAD BALANCED MAGNETIC DOOR CONTACT TELEPHONE/COMPUTER RACEWAY SYSTEM GROUND OR GROUND ROD AS NOTED CONDUIT STUB CONDUIT CONTINUED THREE-WAY KEY SWITCH (XD/XV) C = ABOVE THE COUNTER W = WALL MOUNTED (60"AFF) D = DATA V = VOICE LIGHTING W COMMUNICATIONS "INFORMATION OUTLET" MTD. AT RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED. PROVIDE BACKBOX AND 1"C. TO ACCESSIBLE CEILING SPACE. COMMUNICATIONS OUTLETS WILL HAVE ONE DATA AND ONE VOICE JACK UNLESS NOTED OTHERWISE. CABLING AND JACKS SHALL BE CAT 6. 60"AFF WALL MOUNTED ANALOG PHONE LINE FOUR-WAY KEY SWITCH S4K SL SINGLE POLE SWITCH WITH SECURITY LOCKING KEY SOC WALL SWITCH WITH OCCUPANCY SENSOR STRIP LIGHT FIXTURE FIXTURE DESIGNATION FAN SWITCH SM MANUAL MOTOR STARTER WITH OVERLOAD HEATERS SMP MANUAL MOTOR STARTER WITH OVERLOAD HEATERS AND PILOT LIGHT SD DIMMER SWITCH (1500 WATTS UNLESS OTHERWISE INDICATED) CIRCUIT NUMBER A TTB a LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG WALL MOUNTED LIGHT FIXTURE WITH WALL OUTLET BOX LIGHT FIXTURE DUPLEX RECEPTACLE EXIT LIGHT FIXTURE DIRECTION ARROWS AS SHOWN (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) PEDESTAL MOUNTED RECEPTACLE WALL MOUNTED EXIT LIGHT FIXTURE FLOOR OUTLET BOX AND DUPLEX RECEPTACLE WITH APPROPRIATE FLANGE. BATTERY PACK WITH TWIN HEADS DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR (PROVIDE ALL ACCESSORIES, POWER PACK, SENSORS, ETC... TO PROVIDE FULL COVERAGE). OS FIRE ALARM/DETECTION SYSTEM POKE THRU POWER POLE PP 3. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 4. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS. 5. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO AVOID CUTTING ON MORTAR JOINTS. 6. ALL MOUNTING HEIGHTS SHOWN ARE TO THE CENTERLINE OF THE DEVICE UNLESS NOTED OTHERWISE. VERIFY ALL OUTLET LOCATIONS ON THE JOB PRIOR TO ROUGH-IN. T TELEPHONE TERMINAL CABINET TELEPHONE SYSTEM RACEWAY TELEVISION TV CATV OUTLET LOCATION. PROVIDE EMPTY BOX AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING WITH PULL STRING. DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER 8. GFI RECEPTACLE MOUNTED ABOVE COUNTER R = RETURN S = SUPPLY J JUNCTION BOX- WALL MOUNTED SS SURGE SUPPRESSOR ST SHUNT-TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS 5 MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER VARIABLE FREQUENCY DRIVE DDC DIRECT DIGITAL CONTROL PANEL 30AR NF XXCD 30AR 20AF MCP SIZE FS MM MONITOR MODULE H ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER H ELECTROMAGNETIC DOOR HOLD OPEN DEVICE CONNECTION TO CLOSURE/ HOLDER INCLUDES DETECTOR H FACP C:\Local Revit\513029 Homestead Ph2 R13\513029-DMA Homestead Phase 2 - LOCAL -R13.rvt INTERRUPTION OF SERVICES: CONTRACTOR SHALL COORDINATE SERVICE INTERRUPTION WITH OWNER AND UTILITY COMPANY AND SHALL NOT INTERRUPT POWER WITHOUT OWNER/ARCHITECT'S PERMISSION. 9. ALL EXISTING SURFACE MOUNTED RACEWAY SERVING DEVICES TO REMAIN SHALL BE CONCEALED. RECEPTACLES FOR ELECTRIC WATER COOLERS SHALL BE LOCATED DIRECTLY BEHIND ELECTRIC WATER COOLER, CONCEALED FROM DIRECT VIEW. 29. ALL LIGHT FIXTURES ARE TO BE LED. PROVIDE APPROPRIATE SWITCHING AND DIMMING DEVICES/ SYSTEMS FOR THE FIXTURE TYPES. 30. CONTRACTOR SHALL UPSIZE BRANCH CIRCUIT WIRE SIZE AS REQUIRED TO COMPENSATE VOLTAGE DROP FROM LENGTHENING OF CIRCUITS DUE TO FIELD ROUTING. FINAL INSTALLATION SHALL MEET FLORIDA BUILDING CODE REQUIREMENT OF: MAXIMUM BRANCH CIRCUIT VOLTAGE DROP OF 3%: Gurri Matute pa 5001 S.W. 74 CT. Suite 208 Miami, Florida 33155 Telephone (305) 661-0069 Fax (305) 661-0089 JOSE G. MATUTE, AIA, CGC, LEED ® AP License No. # AR 0014415 Certificate No. # AA 0003454 Civil Engineer Avino and Associates, Inc. 1350 S.W. 57 Ave. Suite 207 West Miami, FL. 33144 Tel. (305)265-5030 Fax (305)265-5033 Jorge R. Avino, P.E. PSM License No. PE 22207 Certificate No. EB5098 Structural, Mechanical, Electrical and Plumbing Engineer: TLC Engineering for Architecture REFER TO VOLTAGE DROP CHART BELOW FOR CONDUCTOR SIZES FOR BRANCH CIRCUITS 120 VOLT (BASIS 1500 WATT) CIRCUIT LENGTH 0 - 70' 71' - 115' 116' - 180' MIN. CONDUCTOR UP SIZE FOR VOLTAGE DROP #12 AWG #10 AWG #8 AWG 13. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED, WITH APPROPRIATE NEMA ENCLOSURE RATING. 34. CONTRACTOR SHALL PROVIDE AN OPERATING MANUAL AND MAINTENANCE MANUAL TO OWNER. THE MANUAL SHALL INCLUDE AT A MINIMUM: (1) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. (2) OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. (3) NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. 35. CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR USE BY ALL TRADES DURING CONSTRUCTION. REMOVE TEMPORARY POWER AT THE COMPLETION OF THE PROJECT. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS TO OBTAIN TEMPORARY ELECTRICAL SERVICE. 36. CONTRACTOR SHALL SUBMIT FOR APPROVAL MAIN AND ALL ADJUSTABLE THE "AS SET" OVERCURRENT PROTECTIVE DEVICE SETTINGS. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. 37. ALL CONDUCTORS SHALL BE COPPER. ALUMINUM CONDUCTORS ARE NOT PERMITTED. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). 38. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONDUITS, FOR THE SECURITY ELECTRONICS SYSTEMS THE SECURITY ELECTRONICS CONTRACTOR (SEC) SHALL PROVIDE AND INSTALL THE WIRE AND CABLE FOR THE SECURITY ELECTRONICS SYSTEMS AND ALL SECURITY ELECTRONICS EQUIPMENT. THE SEC SHALL SUPERVISE THE CONDUIT INSTALLATION AND VERIFY EXACT BACK BOX LOCATIONS AND CONDUIT STUB-UP LOCATIONS IN THE EQUIPMENT ROOMS. A. WORKING CLEARANCES AND DEDICATED SPACE FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110. SUBMIT COORDINATION DRAWINGS OF ELECTRICAL ROOMS SHOWING COMPLIANCE. 14. B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. E. PROVIDE A WALL AROUND OUTLETS LARGER THAT 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. 39. FIELD VERIFY LOCATION OF AREA SMOKE DETECTORS AND HEAT DETECTORS. DO NOT LOCATE WITHIN 36" OF A HVAC DIFFUSER (SUPPLY OR RETURN), IN A DIRECT AIR FLOW PATH OR WITHIN 36" OF A SPRINKLER HEAD. SMOKE DETECTORS FOR DOOR RELEASE SHALL BE LOCATED ON THE CENTER LINE OF THE DOOR AND A MAXIMUM OF 5 FEET FROM THE DOOR. THE MINIMUM DISTANCE FROM THE DOOR IS THE DEPTH OF THE WALL SECTION ABOVE THE DOOR, BUT NOT LESS THAN 12". 40. LABEL REMOTE ALARM INDICATOR FOR DUCT MOUNTED SMOKE DETECTORS (IE: RTU-1 SUPPLY, RTU-2 RETURN, FIRE/SMOKE DAMPER, ETC.). DUCT DETECTORS SHOULD BE LOCATED IN THE AREA BETWEEN 6 AND 10 DUCT EQUIVALENT DIAMETERS OF STRAIGHT, UNINTERRUPTED DUCTWORK. DUCT DETECTORS FOR FIRE/SMOKE DAMPERS SHOULD BE LOCATED BETWEEN THE LAST INLET OR OUTLET UPSTREAM OF THE DAMPER AND THE FIRST INLET OR OUTLET DOWNSTREAM OF THE DAMPER. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. 874 Dixon Boulevard Cocoa , FL. 32922 Tel. (321)636-0274 Fax (321)639-8986 Gary C. Krueger Licenses No. PE 40788 James Wamsley Licenses No. PE 50343 John W. Riner P.E. Licenses No. PE 66867 Certificate No. 00015 H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. 15. ALL CONDUCTORS INSTALLED ABOVE THE ROOF SHALL BE DERATED FOR AMBIENT TEMPERATURE INCLUDING AMBIENT TEMPERATURE ADJUSTMENT IN ACCORDANCE WITH ARTICLE 310.15 (B)(2)(c). 41. 16. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES FOR DRINKING FOUNTAIN, WATER COOLERS, HEAT TRACE, ELEVATOR ROOMS AND SHAFTS, MECHANICAL ROOM, JANITOR CLOSETS, OUTDOORS, KITCHENS AND ALL OTHER LOCATIONS WITHIN 6 FEET OF A SINK OR OTHER WATER SOURCE IN ACCORDANCE WITH THE NEC. EQUIPMENT SHUTDOWN RELAY SHALL BE LOCATED WITHIN 3 FEET OF THE EQUIPMENT CONTROLS AND THE WIRING TO THE RELAY SHALL BE MONITORED. 42. FOR EACH FIRE/SMOKE DAMPER: INTERLOCK WITH FIRE ALARM CONTROL PANEL TO CLOSE FIRE/SMOKE DAMPER AND TO CONTROL THE ASSOCIATED MECHANICAL UNIT PER THE MECHANICAL SEQUENCE OF OPERATIONS. PROVIDE SURGE PROTECTION AS REQUIRED FOR NFPA 780 4.18.2 FOR ANY POWER OR LOW VOLTAGE (FIRE ALARM, TELECOM, ETC.) CIRCUIT EXITING THE BUILDING. 43. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT, 1/2" MINIMUM. ALL CONDUIT IN PUBLIC AREAS SHALL BE CONCEALED UNLESS NOTED OTHERWISE. 44. COORDINATION DRAWINGS THIS PROJECT REQUIRES SUBMISSION OF COORDINATION DRAWINGS. THE DIVISION 15 CONTRACTOR IS RESPONSIBLE FOR THE INITIATION AND PREPARATION OF THE COORDINATION DRAWINGS. THIS CONTRACTOR SHALL PARTICIPATE IN THE COORDINATION DRAWING PREPARATION PROCESS AND PROVIDE ALL NECESSARY INFORMATION REQUIRED TO COORDINATE ALL TRADE INFORMATION. REFER TO DIV. 15 SPECIFICATIONS FOR DETAILS. CEILING HEAT DETECTOR 135° F UNLESS OTHERWISE INDICATED. 18. FIRE ALARM CONTROL PANEL/VOICE EVACUATION PANEL FIRE ALARM TERMINAL CABINET FAAP FIRE ALARM ANNUNCIATOR PANEL WITH VOICE EVACUATION MICROPHONE- FLUSH MOUNTED LOC VOICE EVACUATION LOCAL OPERATING CONSOLE 1 NEMA STARTER SIZE FSD BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, FLUSH MOUNTED 8. 28. FATC ENCLOSURE NEMA RATING. BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED SEE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF LIGHT FIXTURES IN CEILINGS, AND ON INTERIOR AND EXTERIOR WALLS. WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE CONTRACTOR SHALL PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION INCLUDING: SINGLE LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM, SITE PLANS AND ALL ELECTRICAL FLOOR PLANS. 17. COMBINATION MAGNETIC MOTOR STARTER, SIZE & # OF POLES 3 POLE UNLESS OTHERWISE NOTED FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK AND OBTAIN CLARIFICATION FROM ARCHITECT/ENGINEER. 33. COMBINATION AUDIBLE/VISUAL NOTIFICATION DEVICE CD = CANDELA RATING (75CD UNLESS NOTED OTHERWISE) SPRINKLER WATERFLOW SWITCH CONNECTION # OF POLES 30/3 0 3R 7. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS NOTED OTHERWISE. ABOVE-COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACK SPLASH TO CENTERLINE OF DEVICE UNLESS NOTED OTHERWISE. SPRINKLER TAMPER SWITCH CONNECTION TS AR DENOTES AMP RATING OF SWITCH AF DENOTES AMP FUSE SIZE LOCATIONS OF EQUIPMENT SPECIFIED BY OTHER TRADES OR PROVIDED BY OWNER ARE APPROXIMATE. COORDINATE EXACT LOCATIONS IN FIELD PRIOR TO ROUGHING IN AND ROUTING CONDUIT. 12. VISUAL SIGNALING UNIT, WALL MOUNTED (NO AUDIO DEVICE) F FUSED DISCONNECT CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING ALL OPENINGS IN EXISTING CONSTRUCTION AFTER REMOVAL OF EQUIPMENT AND ELECTRICAL DEVICES. REFER TO ARCHITECTURAL DRAWINGS FOR PATCHING/DRYWALL REPLACEMENT INSTRUCTIONS. PROVIDE BLANK COVERPLATES WHERE DEVICES ARE BEING REMOVED FROM EXISTING WALLS TO REMAIN. MATCH COLOR OF EXISTING DEVICE. PROVIDE HACR RATED CIRCUIT BREAKERS FOR ALL HVAC EQUIPMENT. FIRE ALARM SPEAKER WITH STROBE - CEILING MOUNTED CD = CANDELA RATING (75CD UNLESS NOTED OTHERWISE) F NON-FUSED DISCONNECT SWITCH, SIZE AS NOTED NF DENOTES NON-FUSED 4. 6. 32. ELECTROMAGNETIC DOOR HOLD OPEN DEVICE VFD ELECTRICAL DEVICES CONCEALED BY STORAGE SHELVING, CASEWORK, FURNITURE, ETC. ARE TO BE REMOVED AS REQUIRED BY DEMOLITION PLANS. COORDINATE INSTALLATION OF ANY DEVICE LOCATED IN MILLWORK WITH ARCHITECTURAL DRAWINGS AND DETAILS PRIOR TO ROUGHING IN BOXES AND ROUTING CONDUIT. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS NOTED OTHERWISE. REMOTE INDICATING LAMP FIRE ALARM WITH TEST SWITCH WALL MOUNTED 72" AFF UNDER GROUND CONCRETE ENCASED DUCTBANK J 3. FOR ALL EQUIPMENT AND WIRING DEVICES BEING REMOVED: REMOVE CONDUCTORS BACK TO PANEL, TURN BREAKER TO "OFF" AND LABEL THE CIRCUIT "SPARE" ON THE PANEL DIRECTORY. WHERE THERE ARE WIRING DEVICES TO REMAIN ON THE BRANCH CIRCUIT, REMOVE CONDUCTORS BACK TO JUNCTION BOX. EMERGENCY BALLAST BATTERY PACKS AND EMERGENCY EXIT SIGNS, WHERE USED, SHALL BE CONNECTED TO UNSWITCHED LEG OF CIRCUIT DESIGNATED ON DRAWINGS. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. PHOTOCELL, MOUNTED ON ROOF FACING NORTH JUNCTION BOX 25. REMOVE ALL CONDUIT LEFT EXPOSED BY REMOVAL OF WALLS AND CEILINGS IN REMODELED AREAS. PLUG BOTH ENDS OF REMAINING CONDUIT IN WALL OR FLOOR WHERE CUT. 5. 31. DUCT SMOKE REMOTE ALARM INDICATING LAMP, W/ TEST SWITCH, WALL MOUNTED 72" AFF F PLUG-IN STRIP WITH RECEPTACLES, 18" O.C. UNLESS OTHERWISE INDICATED PROVIDE A PERMANENT SIGN ON THE MAIN ELECTRICAL ROOM DOOR TO THE BUILDING STATING THAT THE MAIN SERVICE DISCONNECTING MEANS ARE LOCATED INSIDE. 2. 181' AND ABOVE TO BE SUBMITTED BY CONTRACTOR AND APPROVED BY ENGINEER. R CLOCK RECEPTACLE GROUND BAR 24. ALL BRANCH CIRCUIT HOMERUNS SHALL BE ROUTED IN 1/2"C. MINIMUM. MC CABLE IS NOT ALLOWED. SUPERVISED CONTROL RELAY RT GND COORDINATE HEIGHTS OF WALL MOUNTED LIGHTING FIXTURES TO CLEAR MIRRORS, CABINETS AND BUILT-INS. EACH BRANCH CIRCUIT RACEWAY SHALL HAVE A FULL SIZE EQUIPMENT GROUND CONDUCTOR. WHERE ISOLATED GROUND CIRCUITS ARE SHOWN ON THE PLANS, PROVIDE AN ISOLATED GROUND CONDUCTOR THROUGHOUT THE LENGTH OF THE CIRCUIT IN ADDITION TO THE PHASE, NEUTRAL AND EQUIPMENT GROUND CONDUCTORS. R ISOLATED GROUND DUPLEX RECEPTACLE, (ORANGE DEVICE) PC EACH DATA, TELEPHONE, VIDEO OR OTHER SYSTEMS OUTLET REQUIRES 3/4"C. STUBBED TO ACCESSIBLE CEILING SPACE UNLESS OTHERWISE NOTED ON PLANS. PROVIDE INSULATED BUSHINGS ON ALL CONDUITS. LABEL CONDUIT TO IDENTIFY ITS INTENDED USE (IE: TELEPHONE, DATA, ETC.). WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE-RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: TWO DUPLEX RECEPTACLES WITH COMMON COVER LIGHTING CONTROL TIME CLOCK 23. 10. DUCT SMOKE DETECTOR SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED COORDINATE THE LOCATION OF ALL DEVICES AND BOXES WITH WINDOWS, BUILT-INS, AND CABINETS PRIOR TO INSTALLATION OF CONDUITS OR BOXES. CONTRACTOR SHALL CONSULT ALL CONTRACT DRAWINGS TO ASCERTAIN ANY CONFLICTS PRIOR TO BIDDING. CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT/ENGINEER. CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL COMPENSATION FOR WORK REQUIRED TO RELOCATE OUTLET BOXES THAT ARE/OR BECOME NECESSARY FOR COORDINATION WITH OTHER TRADES WORK. PROVIDE 18" LONG (MIN). CONDUIT SLEEVES THRU ALL WALLS WHERE CABLES ARE INDICATED OR REQUIRED TO PASS THRU WALLS. PROVIDE BUSHINGS ON BOTH ENDS. SIZE CONDUIT FOR CABLES INSTALLED. AT CABLE TRAYS, PROVIDE ONE 4" CONDUIT SLEEVE FOR EACH 4" WIDTH OF CABLE TRAY. GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. C 22. 9. CEILING SMOKE DETECTOR, PHOTO-ELECTRIC TYPE UNLESS OTHERWISE NOTED WP IG ALL BRANCH CIRCUIT CONDUITS SHALL CONTAIN A MINIMUM OF (2) #12AWG INSULATED COPPER CONDUCTORS, PLUS A MINIMUM OF (1) #12AWG GROUND WIRE UNLESS NOTED OTHERWISE. ALL BRANCH CIRCUITS AND FEEDERS SHALL HAVE INDIVIDUAL NEUTRAL CONDUCTORS. MANUAL PULL STATION F TWO DUPLEX RECEPTACLES WITH COMMON COVER MOUNTED ABOVE COUNTER 21. 27. TELEPHONE/COMPUTER TERMINAL BOARD 7. TTC ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP. 26. 11. FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES AND ONE COMBINATION W/ VOICE/DATA OUTLET P REFER TO THE ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPE, INTERIOR DESIGN, TECHNOLOGY AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION AND ADDITIONAL INSTALLATION REQUIREMENTS TO BE PERFORMED AS PART OF THE WORK. TELEPHONE OUTLET FLOOR MOUNTED 2 FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE AND ONE COMBINATION W/ VOICE/DATA OUTLET 2. PHONE/DATA AS INDICATED ON DRAWINGS. LIGHT FIXTURE SF 1. STATE OF FLORIDA. 2. LIFE SAFETY CODE - NFPA 101. 3. UNDERWRITERS LABORATORIES, INC. PUBLICATIONS 4. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). 5. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 6. NATIONAL ELECTRICAL CODE - NFPA 70. 7. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE). 8. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA). 9. REQUIREMENTS OF LOCAL POWER COMPANY. 10. 2010 FLORIDA BUILDING CODE. 11. THE AMERICANS WITH DISABILITIES ACT (ADA) 12. FLORIDA ACCESSIBILITY CODE. 13. MIAMI-DADE COUNTY, CITY OF HOMESTEAD 20. 45. LOCATE A 20A/1P/120V. RECEPTACLE WITHIN 6" OF EACH DATA OUTLET AT THE SAME HEIGHT. 46 FACEPLATES FOR ALL DEVICES IN MECHANICAL, ELECTRICAL AND COMM ROOMS SHALL BE STAINLESS STEEL. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2010 FLORIDA BUILDING CODE. THE FLORIDA FIRE PREVENTION CODE (2010) AND ALL LOCAL CODES AND ORDINANCES. 120V FIRE/SMOKE DAMPER SM FSD DH SMOKE DETECTOR WIRED TO SECURE POWER TO FIRE/SMOKE DAMPERS. ALSO TO BE MONITORED BY FACP. SMOKE DETECTOR WIRED TO SECURE POWER TO DOOR HOLD OPEN DEVICES. ALSO TO BE MONITORED BY FACP. NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. LIGHTNING PROTECTION SYSTEM CONTRACTOR SHALL PROVIDE A COMPLETE, FULLY CONCEALED, ROOF AND SITE MOUNTED LIGHTNING PROTECTION SYSTEM FOR THE ENTIRE FACILITY PER THE REQUIREMENTS OF THE DIVISION 16 SPECIFICATIONS. SYSTEM SHALL BE DESIGNED AND INSTALLED PER NFPA 780 & SHALL BE UL LISTED. PROVIDE LIGHTNING PROTECTION FOR ALL SITE LIGHTING AND FLAGPOLES, ETC. 1 ISSUE PRELIMINARY DESIGN 100% PROGRESS SET BID SET ADDENDUM 2 DATE 03-27-13 01-31-14 03-12-14 03-28-14 DRAWING TITLE ELECTRICAL ABBREVIATIONS, LEGEND, SYMBOLS AND NOTES DATE MARCH 9, 2009 1304.00 Project No.. 3/28/2014 1:40:25 PM Building 756, Schweinfurt Rd, HOMESTEAD, FL 33092 S3 DESCRIPTION REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXTENT OF DEMOLITION WORK. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT ELECTRICAL SERVICES TO ALL EQUIPMENT BEING REMOVED. OWNER SHALL HAVE THE OPTION TO RETAIN REUSABLE ITEMS SUCH AS COVERPLATES, RECEPTACLES, LIGHTS, PANELS, ETC.. NOT BEING USED IN THE FINISHED WORK. COORDINATE WITH OWNER PRIOR TO STARTING DEMOLITION. PROPERLY AND LEGALLY DISPOSE OF ALL EQUIPMENT AND MATERIALS BEING REMOVED. HOMESTEAD NATIONAL GUARD ARMORY RENOVATION BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). SINGLE POLE SWITCH (SUBSCRIPT INDICATES ITEM CONTROLLED) SWPL SYMBOL 1. Project Name: DESCRIPTION ALL WIRING DEVICES SHALL BE MOUNTED VERTICALLY, UNLESS NOTED OTHERWISE. STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS (DMA) Sa SYMBOL 19. Owner: DESCRIPTION ALL WORK AND EQUIPMENT UNDER THIS DIVISION SHALL BE IN STRICT COMPLIANCE WITH THE CODES, STANDARDS AND PRACTICES LISTED HEREIN, AND THEIR RESPECTIVE DATES ARE FURNISHED AS THE MINIMUM LATEST REQUIREMENTS. State Project #: SYMBOL DOOR CONTROL SYSTEM BASIC MATERIALS CONT. Architect: 1. 207013 BASIC MATERIALS DEMOLITION NOTES: GENERAL NOTES: DRAWN PJM CHECK JWR SHEET E0.00 John W. Riner, P.E. Florida License #66867 SEAL M1-2,4,6 HVAC CONTROLS M1-29 M1-30 M1 EXISTING ENCLOSED YARD N.I.C. VFD J 3 30 * M1-14,16,18 AHU-4 Architect: 3/4"C FOR CONTROLS (TYP OF 3) REC J P1-9 REC J P1-11 P2-26,28 6 REC J P1-15 FSD 6 REC J P1-10 EXISTING OFFICE 101 FCU-1 P2-34,36 ELECTRIC WATER HEATER NEW FEMALE RESTROOM 102 P1-12 72"AFF P1-35 6 P1-12 NEW MALE RESTROOM EF-1 104 P1-14 REC P2-38,40 J P1-14 EXISTING OFFICE 105 M 72"AFF 6 LIGHTING CONTACTOR LC-1 REC P2-37,39 J P1-16 EXISTING OFFICE 106 FCU-1 FCU-1 M1-29 J HVAC CONTROLS 3 M1-7,9,11 VFD Gurri Matute pa 3 30 * 60 * 5001 S.W. 74 CT. Suite 208 Miami, Florida 33155 Telephone (305) 661-0069 Fax (305) 661-0089 JOSE G. MATUTE, AIA, CGC, LEED ® AP License No. # AR 0014415 Certificate No. # AA 0003454 M1-29 M1-1,3,5 EXISTING OFFICE 125 FCU-1 P2-18,20 J P1-19 6 REC J 6 ERU-1 HVAC CONTROLS M1-30 P3 Civil Engineer HVAC CONTROLS Avino and Associates, Inc. FCU-1 P1-6 EXISTING CORRIDOR 100 M P1-29 P1-16 30/3 00 DP-5 EXISTING AHU-1 MECHANICAL CONNECT 124 TO EDH-1 P1-37 DP DP-4 3 30 P1 * ELEC. ROOM STO/ELEC. J 122 123 P2 P1-29 NEW JAN. CLOSET 103 P1-5 REC J P3-2 EXISTING SIPR ROOM REC J P3-4 AC-3 REC J P3-6 N.I.C. EXISTING PLUGMOLD TO REMAIN P1-13 72"AFF P1-12 6 AC-1 P2-22,24 6 REC J P1-13 6 FSD M NEW OFFICE 119 FCU-1 M M P2-30,32 M NEW FCU-1OFFICE 118 EXISTING CONFERENCE ROOM 117 FCU-2 REC J P3-5 AC-2 J P3-7 J P3-9 REC REC 6 M1-29 P1-17 3/4"C FOR POWER (TYP OF 3) M1-8,10,12 M1-30 J P1-17 WP AHU-3 1350 S.W. 57 Ave. Suite 207 West Miami, FL. 33144 Tel. (305)265-5030 Fax (305)265-5033 Jorge R. Avino, P.E. PSM License No. PE 22207 Certificate No. EB5098 P3-8 6 6 6 REC P2-33,35 J P1-18 EXISTING OFFICE 107 REC P2-29,31 J P1-20 EXISTING OFFICE 108 REC P2-25,27 J P1-22 NEW OFFICE 109 FCU-1 FCU-1 FCU-1 6 REC J P1-24 P2-21,23 NEW OFFICE 110 6 REC J P1-30 EXISTING OFFICE FCU-1 112 P2-17,19 N FCU-1 3 P1-33 Structural, Mechanical, Electrical and Plumbing Engineer: TLC Engineering for Architecture MEZZANINE POWER PLAN 1/4" = 1'-0" J P1-31 874 Dixon Boulevard Cocoa , FL. 32922 Tel. (321)636-0274 Fax (321)639-8986 Gary C. Krueger Licenses No. PE 40788 James Wamsley Licenses No. PE 50343 John W. Riner P.E. Licenses No. PE 66867 Certificate No. 00015 MATCHLINE 1/E3.01 MATCHLINE 2/E3.01 EXISTING EXTERIOR RECEPTACLES 2 EXISTING ENCLOSED YARD N.I.C. FIRST FLOOR POWER PLAN 1/8" = 1'-0" 1 CH-1 2 CH-2 2.5 3 4 EXISTING UTILITY TRANSFORMER 1 EXISTING METER K-12 MDP-8 P4-2 WP 3 200 NF GENERAL NOTES: MDP-9 DN 3 200 NF K-20 RELOCATED FCU-1 OFFICE 176 K-9 1 NEW SERVICE ENTRANCE FUSED DISCONNECT SWITCH. INTERCEPT EXISTING UNDERGROUND CONDUIT. 2 CONNECT ANY RECEPTACLES LOCATED ON WALLS TO REMAIN (CORRIDOR & EXTERIOR WALLS, ETC.) TO SAME CIRCUIT USED FOR RECEPTACLES IN EACH ROOM. 3 NEW GENERATOR DOCKING STATION. REFER TO ONE-LINE DIAGRAM. 4 CONNECT FPL UTILITY FEED FROM SERVICE DISCONNECT TO MTS. DN 6 DN P6-19,21 P6-8 4 E3.01 P4-38 WP POWER OUTLET FOR WIFI ACCESS POINT LOCATED ON SHELF ABOVE CEILING. P4-5 7 EXIST. COMM. 175 P4-5 P4-6 HVAC CONTROLS 6 P4-5 P4-4 P5-10 M1-19 REC J P4-27 REC J P4-29 REC J P4-31 72"AFF M1-19 MATCHLINE 1/E3.01 EXISTING OFFICE 126 P2-14,16 P6-11 P6-15 NEW RACK REC J P1-23 6 6 M P6-13 J 6 P2-2,4 M P6-15 6 REC P2-9,11 J P1-34 EXISTING OFFICE 114 FCU-1 FCU-1 REC J P1-36 P2-5,7EXISTING OFFICE 115 FCU-1 DOOR HOLD OPEN P1-27 72"AFF M FSD P4-12 M1-13 M1-13 M1-15 M1-17 NEW OFFICE 159 M1-17 M1-25 NEW MALE RESTROOMS 162 P4-14 DN P4-14 72"AFF 6 P1-38 REC J P4-20 EXISTING WAITING AREA P6-17 130 REC J P1-38 P2-1,3 EXISTING OFFICE 116 6 FSD GWH-1 M1-25 M1-21 VAV-1-9 M1-13 ISSUE PRELIMINARY DESIGN 100% PROGRESS SET BID SET ADDENDUM 2 DATE 03-27-13 01-31-14 03-12-14 03-28-14 NEW MALE SHOWERS 164 WP M1-17 M1-15 P5-3 NEW RECRUITER'S P5-3 OFFICE 132 FSD P5-1 P5-3 P5-16 P5-2 P5-7 NEW P5-11OFFICE 134 P5-11 NEW OFFICE 133 P5-7 NEW OFFICE 142 P5-17 VAV-1-6 NEW OFFICE 143 P5-21 P5-29 P5-25 P5-21 P5-25 CORRIDOR 146 P5-2 72"AFF NEW RECRUITER'S OFFICE 131 P5-5 P5-21 NEW OFFICE 144 P5-25 P5-2 VAV-1-10 P5-2 72"AFF P5-15 NEW OFFICE P5-15 135 P5-15 P5-7 P5-11 P5-15 NEW OFFICE P5-29 145 P5-29 72"AFF P5-11 NEW P5-19 OFFICE 136 P5-19 P5-19 P5-27 NEW P5-27 OFFICE 72"AFF 138 NEW P5-23 OFFICE 137 P5-23 P5-23 DN 6 FSD P5-17 P5-13 NEW OFFICE VAV-1-5 141 P5-13 REC P4-21 J P5-28 P5-18 P5-17 NEW OFFICE 140 P5-9 EXISTING FSD M CORRIDOR 160 P4-14 P5-27 P5-27 P5-31 NEW OFFICE P5-31 139 P5-31 P5-31 P4-14 P5-30 REC J P5-37 EXISTING 6 OFFICE 148 VAV-1-12 VAV-1-11 REC J P5-33 REC J P5-35 EXISTING 6 OFFICE 147 REC J P5-39 EXISTING OFFICE 149 6 P5-35 72"AFF P5-39 C 72"AFF P5-4 6 M P5-32 DRAWING TITLE POWER PLAN REC J P5-4 EXISTING OFFICE 151 72"AFF EXISTING OFFICE 6 150 P5-41 REC J P5-41 P5-41 DATE MARCH 9, 2009 1304.00 Project No.. 1 DN MATCHLINE 1/E3.01 1 M1-32 NEW MALE DRYING ROOM 163 P5-26 P5-24 60"AFF 2 P5-13 P5-9 P5-9 P5-5 FCU-1 REC J P4-21 P4-14 J DN MATCHLINE 2/E3.01 B NEW CORRIDOR 161 M1-17 M1-15 VAV-1-8 P5-20,22 VAV-1-7 M P5-12,14 FOR MAGLOCK ACCESS CONTROL POWER 3/28/2014 1:40:29 PM EXISTING TRAINING ROOM 155 P4-17 VAV-1-4 M REC P2-13,15 J P1-32 EXISTING OFFICE 113 6 REC J P4-22 REC J P4-24 M1-15 NEW OFFICE 158 M1-13 NEW OFFICE 157 REC J P4-28 REC J P4-30 REC J P4-32 EXISTING TRAINING ROOM 156 P4-42 J DOOR HOLD OPEN 6 6 M1-32 M1-31 M1-25 P4-32 6 6 P1-29 M1-23 JANITOR ROOM 171 M1-21 M1-21 M1-19 VAV-1-2 72"AFF P4-22 P4-18 WP FSD REC J P1-27 P1-25 72"AFF NEW MAIL ROOM P4-15 P4-15 152 NEW STORAGE ROOM 172 NEW OFFICE 173 M1-19 72"AFF P4-24 P5-8 M EXISTING VAULT J P4-19 REC N.I.C. EXISTING FCU-1 OFFICE 129 J P4-42 80"AFF ENLARGED EXIST COMM 175 - POWER 4 1/4" = 1'-0" EXISTING OFFICE 128 FCU-1 P2-6,8 REC J P1-25 6 FSD P6-11 P6-13 EXISTING OFFICE 127 FCU-1 P2-10,12 REC J P1-21 AC-4 (2) 3/4" CONDUITS TO CU-4 (1) FOR POWER AND (1) FOR CONTROLS M MATCHLINE 2/E3.01 P4-12 72"AFF P4-12 P4-16 FCU-1 CABLE SCHEDULE AND CABLE DISTRIBUTION DRAWING. M1-19 P4-9 P4-10 M C:\Local Revit\513029 Homestead Ph2 R13\513029-DMA Homestead Phase 2 - LOCAL -R13.rvt EF-2 UP M1-27 M1-21 P4-36 P4-11 NEW P5-6 BREAK ROOM VAV-1-1 153 P4-12 P4-14 P4-12 FSD 72"AFF P4-14 P4-16 P4-16 A DN WP 6 P4-39 NEW FEMALE SHOWERS 167 NEW STAIR 178 K-10 NEW FEMALE RESTROOMS 165 M1-27 P4-3 120V FOR SPRINKLER BELL P4-8 NEW FEMALE DRYING ROOM 166 7 VAV-1-3 P4-37 K-5 P4-35 EXISTING MEETING ROOM 154 FLUSH FLOOR BOX. P4-26 BASIS OF DESIGN: REC J P4-23 WIREMOLD EVOLUTION. 6 REC J P4-25 60"AFF P4-26 J FACP J K-4 GWH-1 P4-13 P6-9 K-7 K P4-34 AHU-2 MDP-7 EXISTING MECH ROOM P4-7 177 HVAC CONTROLS NEMA L5-30R TTB P4-33 P4-41 J VFD 4 K-6 REFER TO MEZZANINE POWER PLAN ABOVE P4-4 MDP EXISTING ELECT. 174 P4 P5 P4-6 MTS P4-38 3 7 P6 K-14 M (2) 3/4" CONDUITS TO AC-4 (1) FOR POWER AND (1) FOR CONTROLS WP M1-27 J DEDICATED SPACE FOR VERTICAL WIREMOLD TO ABOVE CEILING, SEE DETAILS ON E8.02. ELECTRICAL DEVICES WITHIN THIS ROOM ARE EXISTING TO REMAIN. SURFACE MOUNTED DEVICES AND CONDUITS SHALL BE RECESSED AND CONCEALED IN WALLS. CIRCUIT DEVICES TO NEW CIRCUIT(S) IDENTIFIED FOR RECEPTACLES IN EACH ROOM. PROVIDE NEW RECEPTACLES AS SHOWN. DOCUMENT EXISTING RECEPTACLES ON AS-BUILTS. K-6 COORDINATE OUTLET QUANTITIES, NEMA CONFIGURATION, WIRE SIZE AND BREAKER SIZE WITH KITCHEN EQUIPMENT SELECTIONS. K-16 K-2 GAS SOLENOID VALVE K-6 LIGHTING CONTACTOR LC-2 CU-4 NEW KITCHEN 168 K-9 NEW DRILL HALL 170 K-2 TO KSF-1 ON ROOF M CODED NOTES: P4-1 K-15,17,19 GWH-2 State Project #: P4-40 P4-1 J J K-22 Owner: P4-2 P4-1 M P4-2 3 30 * NEW K-2 PANTRY J 169 K-8 P4-3 2. FCU-1 AND FCU-2 DISCONNECTS ARE INTEGRAL TO EQUIPMENT. 6 M WP K-1 1. COORDINATE ANY OUTAGES WITH OWNER. 5 KEF-1 K-13 WP HOOD CONTROL AND HOOD LIGHTING 207013 N STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS (DMA) NEW BICYCLE STORAGE 179 Building 756, Schweinfurt Rd, HOMESTEAD, FL 33092 CU-3 DN CONNECT TO EDH-3 HOMESTEAD NATIONAL GUARD ARMORY RENOVATION P3-15,17 Project Name: P3-1,3 CU-1 MATCHLINE 1/E3.01 P3-11,13 CU-2 MATCHLINE 2/E3.01 CONNECT TO EDH-4 DRAWN PJM CHECK JWR DN SHEET N 1 FIRST FLOOR POWER PLAN 1/8" = 1'-0" E3.01 John W. Riner, P.E. Florida License #66867 SEAL 4 EXISTING ENCLOSED YARD N.I.C. 1D MATCHLINE 1/E4.01 Architect: DN S F MATCHLINE 2/E4.01 AHU-4 AHU-3 W 1D W EXISTING MECHANICAL 124 5001 S.W. 74 CT. Suite 208 Miami, Florida 33155 Telephone (305) 661-0069 Fax (305) 661-0089 JOSE G. MATUTE, AIA, CGC, LEED ® AP License No. # AR 0014415 Certificate No. # AA 0003454 EXISTING OFFICE 125 ERU-1 2 F FSD F F FSD NEW JAN. CLOSET 103 F 72"AFF TV F EXISTING OFFICE 101 NEW FEMALE RESTROOM 102 2 1 NEW MALE RESTROOM 104 F F EXISTING OFFICE 105 EXISTING CORRIDOR 100 8 1D Civil Engineer 9 Avino and Associates, Inc. 7 1350 S.W. 57 Ave. Suite 207 West Miami, FL. 33144 Tel. (305)265-5030 Fax (305)265-5033 Jorge R. Avino, P.E. PSM License No. PE 22207 Certificate No. EB5098 8 F 72"AFF TV EXISTING OFFICE 106 2 EXISTING OFFICE 107 2 EXISTING OFFICE 108 2 NEW OFFICE 109 NEW OFFICE 110 EXISTING OFFICE 112 2 2 2 2 MEZZANINE SYSTEMS PLAN 1/4" = 1'-0" MATCHLINE 1/E4.01 MATCHLINE 2/E4.01 3 874 Dixon Boulevard Cocoa , FL. 32922 Tel. (321)636-0274 Fax (321)639-8986 Gary C. Krueger Licenses No. PE 40788 James Wamsley Licenses No. PE 50343 John W. Riner P.E. Licenses No. PE 66867 Certificate No. 00015 NEW BICYCLE STORAGE 179 N 2 EXISTING ENCLOSED YARD N.I.C. FIRST FLOOR SYSTEMS PLAN 1/8" = 1'-0" 1 2 2.5 3 4 RELAY TO COMMUNICATE ANSUL ACTIVATION TO FACP AND SHUT GAS SOLENOID VALVE. DN GENERAL NOTES: F F 1. LOCATE ALL DATA OUTLETS WITHIN 6 INCHES OF A 120V RECEPTACLE. R NEW PANTRY 169 F F 2D 3 3 WALL MOUNTED ACCESS CONTROL MASTER STATION, AIPHONE AX-8MV. MOUNT AT 60" AFF. AHU-2 EXISTING MECH ROOM 177 S (2) ANALOG VOICE JACKS FOR FACP NEW SPRINKLER BELL IN EXISTING LOCATION 2" CONDUIT WITH 25 PAIR COPPER FROM AT&T DEMARK IN ROOM 123 TO EXISTING COMM 175. FIELD COORDINATE ROUTING WITH OTHER TRADES. B 60"AFF J F 60"AFF 1D (4) 4" CONDUIT SLEEVES ABOVE CEILING 2D FACP WITH VOICE EVAC TS FS 2D 2D 2D 2D 2D 2D 2D TV 72"AFF 2 2 EXISTING OFFICE 126 EXISTING OFFICE 127 2 2 EXISTING OFFICE 128 EXISTING OFFICE 129 2D 2D EXISTING TRAINING ROOM 155 C EXISTING VAULT N.I.C. 6 NEW OFFICE 157 EXISTING TRAINING ROOM 156 NEW OFFICE 158 NEW OFFICE 159 B NEW CORRIDOR 161 F 2D NEW MAIL ROOM 152 W 2D 2D 2D 2D 2D 2D F TV NEW MALE SHOWERS 164 NEW MALE DRYING ROOM 163 60"AFF 1 ISSUE PRELIMINARY DESIGN 100% PROGRESS SET BID SET ADDENDUM 2 DATE 03-27-13 01-31-14 03-12-14 03-28-14 1D W NEW PLYWOOD (3 SIDES) 18" LADDER TRAY 2D TV 72"AFF DH TV 72"AFF FSD FSD 1 F F 72"AFF F PS2420 POWER SUPPLIES 2 FAAP WITH LOCAL MIC. 72"AFF TV EXISTING OFFICE 113 ENLARGED EXIST COMM 175 - SYSTEMS 1/4" = 1'-0" 2 EXISTING OFFICE 114 2 EXISTING OFFICE 115 EXISTING WAITING AREA 130 EXISTING OFFICE 116 2 2 2 2 DN DH DH FSD 4 (4) 4" CONDUIT SLEEVES 10 F? 9 NEW RACK 30" MIN DH DN EXISTING CORRIDOR 160 F FSD FSD 2 NEW OFFICE 140 NEW RECRUITER'S OFFICE 132 2 NEW OFFICE 142 2 NEW OFFICE 143 CORRIDOR 146 8 8 NEW RECRUITER'S OFFICE 131 2 NEW OFFICE 133 2 NEW 72"AFF TV OFFICE 134 2 TV 72"AFF 2 NEW OFFICE 137 NEW OFFICE 136 2 2 NEW TV OFFICE 72"AFF 138 2 NEW TV OFFICE 72"AFF 139 2 MATCHLINE 1/E4.01 2 EXISTING OFFICE 151 2 EXISTING OFFICE 147 TV 72"AFF 2 EXISTING OFFICE 149 2 TV 72"AFF 2 SYSTEMS PLAN 2 EXISTING 2 OFFICE 150 2 2 DN MATCHLINE 2/E4.01 EXISTING OFFICE 2 148 2 F NEW OFFICE 135 C DRAWING TITLE NEW OFFICE 145 NEW OFFICE 144 8 F TV 2 2 F F 4 2 NEW OFFICE 141 DN 3/28/2014 1:40:31 PM NEW MALE RESTROOMS 162 JANITOR ROOM 171 2D 2D NEW STORAGE ROOM 172 NEW OFFICE 173 72"AFFTV TV 72"AFF TV 72"AFF 2 2D (2) 4" CONDUIT SLEEVES 2D ABOVE CEILING TV 72"AFF 2D 5 2D 2D NEW BREAK ROOM 153 NEW FEMALE RESTROOMS 165 F W ONE CAT 6E DATA CABLE, CONNECT TO EXISTING SWITCH IN SIPR ROOM. CABLE SHALL BE IN CONDUIT (1" MIN) ALL THE WAY BACK TO EXISTING COMM 175. FIELD COORDINATE ROUTING WITH OTHER TRADES. TRENCH 1" C FOR A/V CABLE EXISTING MEETING ROOM 154 F 2D UP F F 1 PROVIDE ONE ANALOG PHONE LINE BACK TO EXISTING COMM ROOM. THE ENTIRE PATH SHALL BE IN CONDUIT (1" MIN). A State Project #: EXIST. COMM. 175 EXISTING ELECT. 174 10 PULLBOX AS REQUIRED BY NEC. C:\Local Revit\513029 Homestead Ph2 R13\513029-DMA Homestead Phase 2 - LOCAL -R13.rvt 2D NEW FEMALE SHOWERS 167 NEW FEMALE DRYING ROOM 166 DN F 9 COORDINATE WITH OWNER WHICH DATA OUTLETS ARE TO BE CONNECTED TO THE PATCH PANEL IN THE CLOSET AT THE BACK OF THE ROOM AND WHICH OUTLETS ARE TO BE CONNECTED INTO THE BUILDING'S NETWORK AT THE MAIN COMM ROOM. W F 8 REFER TO MEZZANINE SYSTEMS PLAN ABOVE 2D MATCHLINE 2/E4.01 7 NEW STAIR 178 F NEW AIPHONE VIDEO DOOR STATION AND CORBY 6522 ACCESS CONTROL KEYPAD. DN F 4 4 E4.01 F DATA DEVICE FOR WIFI ACCESS POINT ON SHELF ABOVE CEILING. COORDINATE WITH HEIGHT OF SHELF. REFER TO ARCHITECTURAL DRAWINGS. 6 F LOCATE NEW PHONE/DATA OUTLETS WITHIN 6 INCHES OF 120V RECEPTACLE. CONFIRM WITH OWNER WHICH WALL THE DATA/VOICE OUTLET IS TO BE INSTALLED IN EACH ROOM PRIOR TO ROUGH-IN. 3 5 W NEW LOCATION FOR RACK AND TTB SERVING CLASS ROOM. MATCHLINE 1/E4.01 2 NEW KITCHEN 168 NEW DRILL HALL 170 F? F DN CODED NOTES: Owner: RELOCATED OFFICE 176 1 Structural, Mechanical, Electrical and Plumbing Engineer: TLC Engineering for Architecture N 2 Building 756, Schweinfurt Rd, HOMESTEAD, FL 33092 2 ELEC. ROOM STO/ELEC. 122 123 W 7 72"AFF TV HOMESTEAD NATIONAL GUARD ARMORY RENOVATION 2 EXISTING SIPR ROOM N.I.C. NEW OFFICE 119 1D Project Name: NEW OFFICE 118 Gurri Matute pa 2 STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS (DMA) EXISTING CONFERENCE ROOM 117 2 207013 2 2 2D 2 DATE MARCH 9, 2009 1304.00 Project No.. DN DRAWN PJM CHECK JWR SHEET N FIRST FLOOR SYSTEMS PLAN 1 1/8" = 1'-0" E4.01 John W. Riner, P.E. Florida License #66867 SEAL EXISTING FPL TRANSFORMER DISCONNECT SWITCH FOR PORTABLE GENERATOR. SEE NOTE 1 MDP (22,000 AIC) 120/208V, 3 PHASE, 4W 800 AMPS Architect: 800 NOTES: 150 400 150 100 100 300 50 90 30 2 50 2 1. UNDERGROUND CONDUIT PATHS ARE TO BE REUSED IF POSSIBLE. AT A MINIMUM, THE CONDUITS FROM THE FP&L TRANSFORMER TO MDP CAN BE PARTIALLY REUSED AND THE CONDUITS FROM MDP TO DP4 SHOULD BE REUSED. 600 1 2. ALL EXISTING ELECTRICAL GEAR IS TO BE REMOVED. SPARE Gurri Matute pa EXISTING 600A MTS SEE NOTE 1 EXISTING CHILLER EXISTING AHU 2 EXISTING AHU 2 5001 S.W. 74 CT. Suite 208 Miami, Florida 33155 Telephone (305) 661-0069 Fax (305) 661-0089 JOSE G. MATUTE, AIA, CGC, LEED ® AP License No. # AR 0014415 Certificate No. # AA 0003454 PUMP 4 EM1 DP4 120/208V, 3 PHASE, 4W 600 AMPS 120/208V, 3 PHASE, 4W 400 AMPS Civil Engineer 600 Avino and Associates, Inc. 50 60 1 100 225 100 100 2 Structural, Mechanical, Electrical and Plumbing Engineer: TLC Engineering for Architecture EXISTING AHU FAN DP4 DP1 874 Dixon Boulevard Cocoa , FL. 32922 Tel. (321)636-0274 Fax (321)639-8986 Gary C. Krueger Licenses No. PE 40788 James Wamsley Licenses No. PE 50343 John W. Riner P.E. Licenses No. PE 66867 Certificate No. 00015 EM2 DP2 STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS (DMA) EXISTING ELECTRICAL ONE-LINE DIAGRAM - BUILDING A SCALE: N.T.S. FEEDER SCHEDULE (CU) NEW GENERATOR DOCKING STATION WITH NEMA 3R ENCLOSURE. BASIS OF DESIGN: TRYSTAR GDS-103P-LM BOND NEUTRAL AND GROUND, CONNECT TO EXISTING GROUND ELECTRODE SYSTEM. EXISTING FPL TRANSFORMER 1-1/2" RGS 15/3 1 20/3 1 35 200 200 100 100 SPARE SPARE 30 20 20 20 20 8 28 C:\Local Revit\513029 Homestead Ph2 R13\513029-DMA Homestead Phase 2 - LOCAL -R13.rvt VD=0.62% VD=0.40% VD=0.40% VD=0.40% 38 3 60 * 3 200 NF 3 200 NF AHU-2 CH-1 CH-2 10,000 AIC P4 K 10,000 AIC P5 65,000 AIC P6 65,000 AIC 65,000 AIC 1-1/4" 3 AWG 8 AWG 1-1/4" 1-1/4" 3 90/3 1 2 AWG 8 AWG 1-1/2" 4 3 19 100/3 1 1-1/2" 1 AWG 8 AWG 4 2" 1-1/2" 3 21 125/3 1 1 AWG 6 AWG 4 22 2" 1-1/2" 3 23 150/3 M1 1-1/4" 4 16 20 VD=1.62% 8 AWG 3 17 SPD 28 1-1/4" 4 AWG 1 18 26 1-1/4" 4 80/3 100 1-1/4" 10 AWG 3 15 100 1-1/4" 4 AWG 1 14 100 10 AWG 4 13 100 1" 6 AWG 1 12 150 1" 3 70/3 400 10 AWG 4 11 1000 3/4" 8 AWG 1 10 120/208V, 3 PHASE, 4W 1000 AMPS 3/4" 3 60/3 (65,000 AIC) 3/4" 10 AWG 4 9 MDP 3/4" 10 AWG 1 8 50/3 VD=0.39% 3/4" 12 AWG 3 40/3 3 SETS OF (4) 400KCMIL, #2/0 GND IN 3"C. 3/4" 4 6 1 CONDUIT 3/4" 12 AWG 1 7 CONNECT TO EXISTING GROUND ELECTRODE SYSTEM. MEASURE GROUND RESISTANCE PER SPECIFICATIONS AND ADD GROUND WIRES IF REQUIRED. 12 AWG 3 30/3 1000A MTS 3-POLE WITH SOLID NEUTRAL 65,000AIC 12 AWG 4 4 5 #3/0 EQUIP. GRD. 3 3 3 SETS OF (4) 400KCMIL IN 3"C CONDUCTORS 4 2 3 1000 65,000AIC 1000 FEEDER SIZE 3 1 3 SETS OF (4) 400KCMIL IN 3"C S.E. RATED BOND NEUTRAL AND GROUND NUMBER NUMBER OF OF SETS CONDUCTORS 1/0 AWG 6 AWG 24 4 2" 25 3 2" 175/3 1 Owner: DESIG. FUSE OR CIRCUIT BREAKER AMP RATING/# POLES State Project #: METER CAN, COORDINATE WITH FPL. 2/0 AWG 6 AWG 26 4 2" 27 3 2" 1 200/3 VD=1.25% 120/208V, 3 PHASE, 4W 400 AMPS 22,000 AIC 400 1 225/3 1 25 100 150 20 60 60 1 VD=1.30% VD=1.30% VD=1.30% 4 33 3 3" 1 EDH-1 3" 3" 500 KCMIL 2" #3/0 4 ONE-LINE DIAGRAM 3-1/2" 3 2 DRAWING TITLE 3 AWG 4 400/3 38 4 AWG 3 1 36 3 30 * 350 KCMIL 4 37 3 30 * 4 AWG 3" 350/3 5 2-1/2" 250 KCMIL 4 35 20 2-1/2" 32 300/3 24 4 AWG 60 34 20 2-1/2" 4/0 AWG 3 250/3 3 AWG 2 1/2" AHU-1 DATE MARCH 9, 2009 1304.00 Project No.. 3/28/2014 1:45:12 PM P1 22,000 AIC P2 22,000 AIC P3 22,000 AIC NEW ELECTRICAL ONE-LINE DIAGRAM - BUILDING A DATE 03-27-13 01-31-14 03-12-14 03-28-14 2-1/2" 4 30 ISSUE PRELIMINARY DESIGN 100% PROGRESS SET BID SET ADDENDUM 2 6 AWG 3 29 31 100 3/0 AWG 4 28 DP Building 756, Schweinfurt Rd, HOMESTEAD, FL 33092 DP5 PN2 HOMESTEAD NATIONAL GUARD ARMORY RENOVATION PN1 Project Name: EXISTING AHU FAN 225 100 207013 50 1350 S.W. 57 Ave. Suite 207 West Miami, FL. 33144 Tel. (305)265-5030 Fax (305)265-5033 Jorge R. Avino, P.E. PSM License No. PE 22207 Certificate No. EB5098 DRAWN PJM CHECK JWR SHEET SCALE: N.T.S. E6.01 NEW ROOF MOUNTED PHOTOCELL AIMED NORTH John W. Riner, P.E. Florida License #66867 SEAL PC 1 P1-6 2 C ELEVATION NOTES: 3 EQUIPMENT RACK FOR FIBER AND COPPER UTP TERMINATIONS. 1 4 5 2 PROVIDE VERTICAL CABLE MANAGEMENT, DOUBLE SIDED, 5" WIDE WITH COVERS FOR FRONT AND BACK. 5 3 FIBER DISTRIBUTION PANEL (FDP). 7 4 SPACE FOR EXPANSION FDP. 5 GROUP "A" PATCH PANELS FOR TERMINATION OF GRAY DATA CABLES. 6 AI PHONE CENTRAL EXCHANGE AX-248C WITH RACK MOUNTING HARDWARE. 7 GROUP "B" PATCH PANELS FOR TERMINATION OF BLUE VOICE CABLES. 8 GROUP "C" PATCH PANELS FOR TERMINATION OF YELLOW DATA CABLES. 9 LAST 2RU, PATCH PANELS REPRESENTING THE BEP. EXTEND TO BACKBOARD BY WAY OF HOUSE CABLES AND TERMINATE ON 66 BLOCKS ADJACENT TO BEP. RED CAT 6 CABLES FOR ANALOG LINES WILL BE INSTALLED ON THE RIGHT HAND SIDE OF THE BEP PP. 5 ROOM XYZ 7 PATCH PANEL LETTER 8 B1 BLUE (VOICE) OUTLET PATCH PANEL B, PORT 1 SPACE FOR OWNER PROVIDED SWITCHES B1 OUTLET IDENTIFIER 9 FACE PLATE IDENTIFICATION: WALL PHONE BUILDING MOUNTED LIGHTS AND FLAG LIGHT P1-8 Architect: SPARE PROVIDE 2 POLE (MIN) ELECTRICALLY OPERATED, ELECTRICALLY HELD LIGHTING CONTACTOR LIGHTING CONTACTOR - LC1 2 4 NEW ROOF MOUNTED PHOTOCELL AIMED NORTH PC P6-8 Gurri Matute pa 5001 S.W. 74 CT. Suite 208 Miami, Florida 33155 Telephone (305) 661-0069 Fax (305) 661-0089 JOSE G. MATUTE, AIA, CGC, LEED ® AP License No. # AR 0014415 Certificate No. # AA 0003454 C 1 RACK MOUNTED UPS. 10 W 3 6 P6-10 SOUTH EXTERIOR LIGHTS 10 P6-12 NORTH EXTERIOR LIGHTS Civil Engineer NOTE: LABEL OUTLETS CLOCKWISE FROM DOOR, NUMBER THE OUTLETS 1,2,3... Avino and Associates, Inc. SPARE 1350 S.W. 57 Ave. Suite 207 West Miami, FL. 33144 Tel. (305)265-5030 Fax (305)265-5033 Jorge R. Avino, P.E. PSM License No. PE 22207 Certificate No. EB5098 PROVIDE 4 POLE (MIN) ELECTRICALLY OPERATED, ELECTRICALLY HELD LIGHTING CONTACTOR SPARE LIGHTING CONTACTOR - LC2 GRAY (DATA) OUTLET PATCH PANEL A, PORT 1 No Scale 7 BLUE (VOICE) OUTLET PATCH PANEL B, PORT 1 A1 A1 OUTLET IDENTIFIER 4 No Scale LIGHTING CONTACTORS - LC1 AND LC2 1 No Scale B1 OUTLET IDENTIFIER 874 Dixon Boulevard Cocoa , FL. 32922 Tel. (321)636-0274 Fax (321)639-8986 Gary C. Krueger Licenses No. PE 40788 James Wamsley Licenses No. PE 50343 John W. Riner P.E. Licenses No. PE 66867 Certificate No. 00015 DEMOLISH EXISTING CONDUIT AND HOMERUN WIRING BLANK C1 1 0'-3_ " 2 ROOM NUMBER NEW CONDUIT AND HOMERUN WIRING. SPLICE INTO EXISTING BRANCH CIRCUIT IN JBOX. RELABEL JBOX WITH CIRCUIT NUMBER OUTLET IDENTIFIER 1 0'-1_" 2 COMMUNICATIONS RACK FACE PLATE IDENTIFICATION: 2 DATA / 1 VOICE 2D/1V PATCH PANEL IDENTIFIER GRAY (DATA) OUTLET PATCH PANEL A, PORT 1 A 101 1 101 2 101 3 101 4 102 1 102 2 102 3 GRAY GRAY GRAY GRAY GRAY GRAY GRAY 1 2 3 4 5 6 7 112 1 112 2 112 3 112 4 113 1 113 2 113 3 GRAY GRAY GRAY GRAY GRAY GRAY GRAY 25 26 27 28 29 30 31 KEEP BRANCH CIRCUIT WIRING AND ABOVE CEILING JBOX EX: EA125-A DEF: RACK 'A' TR EA125 STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS (DMA) COLOR OF ICON ON PATCH PANEL SHALL MATCH THE COLOR OF CORRESPONDING ICON ON THE INFORMATION MANAGEMENT OUTLET WALL SHOWN TO REMAIN (SEE ARCHITECTURAL PLANS) ENGRAVED PLASTIC TAG WITH 1/4" HIGH WHITE LETTERS ON BLACK BACKGROUND. TAG SHALL HAVE ALL EDGES BEVELED AND SMOOTH. SECURE TAG WITH PERMANENT DOUBLE SIDED TAG TAPE OFFSET FROM CENTER ON BLANK PLATE AS INDICATED. ROOM XYZ PATCH PANEL LETTER BLUE (VOICE) OUTLET PATCH PANEL B, PORT 1 A1 MFR'S STENCIL PORT NUMBER B1 Owner: A1 EXISTING DEVICE IN WALL TO REMAIN, LABEL WITH NEW CIRCUIT OUTLET IDENTIFIER ALL LABELING SHALL BE MACHINE GENERATED, AND INSTALLED UNDER FACTORY PLASTIC COVER. BLANK TYPICAL PATCH PANEL LABEL DETAIL 8 No Scale FACE PLATE IDENTIFICATION: 1 DATA / 1 VOICE TYPICAL RACK LABEL DETAIL 5 No Scale WIRING METHOD FOR EXISTING DEVICES LOCATED IN WALLS TO REMAIN 2 No Scale #3/0 AWG COPPER CABLE TO MAIN SERVICE GROUND POST #3/0 AWG COPPER TO BUILDING STEEL State Project #: BLANK 20" INSULATOR MOUNTING BRACKET (TYP.) CPI 10622-000 STUB CONDUIT FOR PHONE/DATA, CONTINUE FOR 120V. GRAY (DATA) OUTLET PATCH PANEL A, PORT 1 207013 YELLOW (DATA) OUTLET PATCH PANEL C, PORT 1 DOUBLE LUG (TYP.) ACT CEILING ROOM XYZ CONDUIT 1/2" FOR POWER 1" FOR PHONE/DATA C:\Local Revit\513029 Homestead Ph2 R13\513029-DMA Homestead Phase 2 - LOCAL -R13.rvt PATCH PANEL LETTER A1 BLANK 4" STUD AND DRYWALL (REFER TO ARCHITECTURAL DRAWINGS). A1 OUTLET IDENTIFIER EXISTING CMU WALL YELLOW (DATA) OUTLET PATCH PANEL C, PORT 1 CPI 10622-020 OR EQUAL DRYVIT COVERING RELAY RACK BASE BLANK RUBBER GROUNDING MAT FINISHED GRADE FACE PLATE IDENTIFICATION: 2 DATA 1 ISSUE PRELIMINARY DESIGN 100% PROGRESS SET BID SET ADDENDUM 2 DATE 03-27-13 01-31-14 03-12-14 03-28-14 PROVIDE # 6 COPPER CABLE DOUBLE LUG CLAMP FOR CABLE CONNECTION DIV. 16 (1) TO EACH RACK PLUS ONE TO PHONE SWITCH ENTRANCE PROTECTOR. MOUNTING BOLT W/ISOLATED WASHERS C1 FRONT VIEW 2D DRAWING TITLE GROUND BUS BAR FACE PLATE ELECTRICAL DETAILS CUT BLOCK WALL FOR DEEP BOXES. STANDOFF BRACKET CPI 10622-000 ISOMETRIC ELEVATION INSULATOR CPI 10622-020 OR EQUAL NOTE: FOR OUTLET IDENTIFIER, SEE DETAIL THIS SHEET. DATE FACE PLATE IDENTIFICATION: 1 3/28/2014 1:40:34 PM INSULATOR (TYPICAL) Building 756, Schweinfurt Rd, HOMESTEAD, FL 33092 TELECOMMUNICATIONS EQUIPMENT RACK ELEVATION Project Name: PATCH PANEL LETTER Structural, Mechanical, Electrical and Plumbing Engineer: TLC Engineering for Architecture HOMESTEAD NATIONAL GUARD ARMORY RENOVATION ROOM XYZ No Scale 10 FLOOR RACK MOUNTING ON SLAB No Scale 9 DEVICE INSTALLATION IN DRILL HALL No Scale 6 GROUND BUS BAR No Scale 3 MARCH 9, 2009 Project No.. 1304.00 DRAWN DS/PJM CHECK JWR SHEET E8.02