Annual Report on Port State Control related to ISM Code

advertisement
Annual Report on Port State Control
related to ISM Code
on Ships with SMC issued by ClassNK
2007
November 2008
NIPPON KAIJI KYOKAI
CONTENTS
Introduction
Chapter 1
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
1
ISM deficiency cases
1.1
Total number and average rate ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
2
1.2
Comparison ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
2
.1
Per factors related to ship ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
2
.2
Per factors related to Company ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
5
.3
Per port state who carried out PSC inspection ・・・・・・・・・・・・・・・・・・・・・・・・・・
8
Chapter 2
ISM deficiencies and PSC actions
2.1
Comparison of deficiencies per ISM Code requirement ・・・・・・・・・・・・・・・・
9
2.2
Comparison of deficiencies and detentions per port state ・・・・・・・・・・・・・・
10
2.3
Analysis of deficiencies recorded along with PSC actions applied ・・・・・
11
Appendix
Extract from PSC inspection reports ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
15
Introduction
This annual report is to offer ship management companies and others concerned with ship
safety management systems analysis of cases where deficiencies related to ISM Code
requirements were recorded as a result of port state control (PSC) inspection, which may be
useful in reviewing a ship safety management system for its improvement.
The analysis was made with information available from reports of PSC inspections that were
carried out in the world in the year 2007 for ships holding an international safety management
certificate issued by ClassNK under the authorization of the flag administration. Statistic data
of such cases in the past several years are also presented to show changes by calendar year.
It comprises of two chapters. Chapter 1 presents analysis of the cases where deficiencies
related to ISM Code requirements were recorded in the PSC reports showing comparison of
number of such cases per type, age, gross tonnage and flag of ship, number of ships under
the management, etc. of Company and port state. Chapter 2 focuses on the deficiencies
recorded and actions required by port states for their rectification.
In this report, terms defined below are used.
NKSMC ship
Ship holding an international safety management certificate issued by
ClassNK
NKDOC company
Company holding a Document of Compliance issued by ClassNK
ISM deficiency
Deficiency of a safety management system related to a requirement of
ISM Code
ISM deficiency case
Case where any ISM deficiencies were recorded in a PSC inspection
report
ISM deficiency ship
Ship having a safety management system an ISM deficiency of which
was recorded in a PSC inspection report
ISM deficiency rate*
percentage of ISM deficiency ships to the whole NKSMC ships or a group
of NKSMC ships in consideration
*
Defining ISM deficiency rate as percentage of ISM deficiency cases to NKSMC ships that subjected to a PSC
inspection is more meaningful. However, as the total number of such NKSMC ships is unknown, the total
number of the whole or a group of NKSMC ships was used instead.
1
Chapter 1
ISM deficiency cases
1.1 Total number and average rate
The total numbers of ISM deficiency cases and the average ISM deficiency rates in the past 4
years are shown in Table 1.1.1. The rate shows increasing tendency since 2006 and became
3.6% in 2007.
Table 1.1.1
Total number and rate of ISM deficiency cases
ISM deficiency
cases
(A)
Year
NKSMC
ships
total No.
(B)
ISM deficiency
rate
(A/B)
2004
137
3639
3.8
2005
81
3799
2.1
2006
121
3895
3.1
2007
142
3993
3.6
1.2 Comparison
1.2.1 Per factors related to ship
(a) Per type of ship
ISM deficiency rate per type of ship is shown in Table 1.2.1(a) and Figure 1.2.1(a).
z
The ISM deficiency rate of bulk carrier was 4.8% and keeping highest apart from chemical
tanker the total number of which is so small to compare.
z
The ISM deficiency rate of oil tanker increased to 2.3% from the rate of 0.6% in 2006.
z
The ISM deficiency rate of gas carrier was 0.5% (only one case) and keeping lowest with the
exception of passenger & modu total number of which is negligible.
Table 1.2.1 (a)
Type of ship
ISM deficiency rate per type of ship
No. of ISM
No. of
deficiency NKSMC ships
cases
2007
2007
(A)
(B)
ISM deficiency rate (%)
2004
2005
2006
2007
(A/B)
Bulk carrier
69
1430
4.4
3.4
4.5
4.8
Other cargo ship
51
1559
4.2
2.2
3.2
3.3
Oil tanker*
18
766
2.5
0.7
0.6
2.3
Chemical tanker**
3
43
2.4
0.0
13.6
7.0
Gas carrier
1
190
0.6
0.0
0.0
0.5
Passenger & MODU
0
5
0.0
0.0
0.0
0.0
142
3993
3.8
2.1
3.1
3.6
Total
* Including oil/chemical tankers.
** Excluding oil/chemical tanker.
2
1 4 .0
2004
2005
2006
2007
1 2 .0
ISM 1 0 . 0
defic.
8 .0
rate
(%)
6 .0
4 .0
2 .0
0 .0
B u lk c a r r ie r
O th e r c a rg o
s h ip
O il t a n k e r
C h e m ic a l
ta n k e r
G a s c a r r ie r
P assenger
& MODU
Figure 1.2.1(a) ISM deficiency rate per type of ship
(b) Per age of ship
The numbers of ISM deficiency ships per age group of ship in 2004 to 2007 are shown in Table
1.2.1(b) together with the numbers of NKSMC ship and the ISM deficiency rates in Figure
1.2.1(b)-1, and ISM deficiency rate per type and age group of ship in 2007 in Figure 1.2.1(b)-2.
z
The older a ship is the greater the ISM deficiency rate tends to be. This tendency is
remarkable for bulk carriers. This is attributed to the increase in the number of deficiencies
due to inadequate maintenance of ship including equipment and fittings with aging of ships.
Table 1.2.1(b)
No. of ISM deficiency ships per age group of ship
No. of ISM deficiency cases (A)
Age
No. of NKSMC ships (B)
2004
2005
2006
2007
2004
2005
2006
2007
0 -
4
17
6
13
14
898
991
1109
959
5 -
9
21
14
25
23
1087
1039
974
855
10 - 14
22
14
15
38
522
599
678
966
15 - 19
21
10
21
13
392
365
367
420
20 - 24
46
30
34
27
529
543
501
364
25 -
10
7
13
27
212
237
266
429
137
81
121
142
3640
3774
3895
3993
Total
10
2004 2005
8
2006 2007
ISM
defic.
6
rate
(A/B)
(%) 4
2
0
0‐4
5‐9
10‐14
15‐19
20-24
25-
Figure 1.2.1(b) -1 ISM deficiency rate per age group of ship
3
14
Bulk carrier
ISM 12
defic. 10
rate
8
(A/B)
6
(%)
Other cargo ship
Oil tanker
4
2
0
0‐4
5‐9
10‐14
15‐19
20-24
25-
Figure 1.2.1(b) -2 ISM deficiency rate (%) per ship type and age group of ship
(c) Per gross tonnage of ship
The numbers of ISM deficiency cases per gross-tonnage group of ship in 2004 to 2007 are shown
in Table 1.2.1(c) together with the numbers of NKSMC ship, and the ISM deficiency rates in Figure
1.2.1(c).
z
The ISM deficiency rate of large ships of more than 80,000 gross tonnage has stayed low
around 1 %. No other remarkable tendency is noticed with gross tonnage.
Table 1.2.1(c) No. of ISM deficiency ships per GT group of ship
No. of ISM deficiency cases (A)
GT
No. NKSMC ships (B)
( x 1,000)
2004
2005
2006
2007
2004
2005
2006
2007
0 - 10
54
22
34
34
1264
1249
1253
1197
10 - 20
36
22
29
44
731
745
755
749
20 - 30
15
11
18
24
474
490
490
488
30 - 40
11
11
18
18
402
445
486
533
40 - 50
8
6
11
10
251
258
289
340
50 - 60
5
0
3
4
140
153
156
168
60 - 80
6
5
4
4
115
127
136
141
80 -
2
4
4
4
263
307
330
377
137
81
121
142
3640
3774
3895
3993
Total
2004
6
2005
5
2006
ISM
4
defic.
rate
3
(A/B)
(%)
2
2007
1
0
0-10
10-20
20-30
30-40
40-50
50-60
60-80
80-
GT ( x 1,000)
Figure 1.2.1(c) ISM deficiency rate per GT group
4
(d) Per flag of ship
ISM deficiency rate per flag of ship in 2004 to 2007 is shown in Table 1.2.1(d) together with the
numbers of ISM deficiency cases.
Table 1.2.1(d)
Flag
Marshall Islands
Bahamas
Thailand
Malaysia
Turkey
St. Vincent and the
Grenadines
Liberia
H.K., China
Cyprus
Panama
Japan
Singapore
Malta
Philippines
(Others)
Total/Average
1.2.2
No.
0
1
2
2
4
ISM deficiency rate per flag of ship
2004
Rate
0.0
3.8
5.8
2.7
4.8
No.
2
1
7
3
2
2005
Rate
5.0
1.5
8.3
4.3
3.5
No.
3
1
5
1
2
2006
Rate
5.3
1.2
5.8
1.7
3.7
No.
5
6
5
3
3
2007
Rate
8.2
6.8
6.7
6.4
6.0
-
-
-
-
-
-
1
5.3
9
13
6
64
14
8
0
14
137
3.9
6.3
12.8
4.6
4.0
7.4
4.0
5.0
1
10
3
40
7
2
2
1
81
0.5
4.1
3.5
1.9
1.7
1.5
2.2
2.1
11
12
12
57
8
2
3
4
121
5.8
4.7
14.8
2.7
1.9
1.6
3.7
3.1
10
10
3
78
4
10
2
1
1
142
5.2
4.3
4.1
3.4
3.0
2.3
1.7
1.2
3.6
Per factors related to Company
Note: The analysis presented in this section covers only NKSMC ships under the management of NKDOC
Companies but not those issued with DOC by another organization.
(a) Per number of ships under management of Company
ISM deficiency rate per group of Companies corresponding to the number of ships under their
management in 2007 are shown in Table 1.2.2(a) together with ISM deficiency rate.
z
The ISM deficiency rate of the group of 41-50 ships is 6.3%, the highest, followed by that of
1-5 ships ,4.3% and next by that of 16-20, 3.9%, which is higher than the average.
z
In 2006 the ISM deficiency rate was higher for the groups with small number of ships under
their management. However, in 2007, the rate increased for the group with larger number of
ships under their management such as the group of 16-20 and that of 41-50 too.
Table 1.2.2(a) ISM deficiency rate per number of ships under management of Company
No. of ships
under
management
No. of
Companies
1-5
6 - 10
11 - 15
16 - 20
21 - 30
31 - 40
41 - 50
51 Total
325
100
36
20
21
13
6
7
528
No. of
ISM deficiency
cases
(A)
32
26
14
14
14
12
17
13
142
5
No. of
NKSMC ships
(B)
742
759
470
356
512
448
270
436
3993
ISM
deficiency
rate
(A/B)
4.3
3.4
3.0
3.9
2.7
2.7
6.3
3.0
3.6
7
6
ISM
defic.
rate
(%)
5
4
3
2
1
0
1-5
6-10
11-15
16-20
21-30
31-40
41-50
51-
No. of ships under management of Company
Figure 1.2.2(a) ISM deficiency rate per No. of ships under management of Company
(b) Per length of Company’s SMS operation
The numbers of ISM deficiency cases and ISM deficiency rate per length of Company’s operation
of ship safety management system in 2007 are shown in Table 1.2.2(b) and Figure 1.2.2(b). The
length of Company’s SMS operation, in terms years, is based on the assumption that the
Companies started such operation when it was issued with NKDOC for the first time.
z
Although the ISM deficiency rate shows lower figures for the groups with 9 years or more of
length of SMS operation there was no significant difference of the figures among all the
groups depending upon the length of the Company’s SMS operation.
Table 1.2.2(b)
Length
of SMS
operation
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Total
ISM
defic.
rate
(%)
ISM deficiency rate per length of Company’s SMS operation
No. of
ISM
deficiency
cases
No. of
(A)
Companies
Per
Total
company
4
2
0.50
24
15
0.63
50
22
0.44
87
26
0.30
65
12
0.18
16
3
0.19
12
4
0.33
30
8
0.27
45
17
0.38
20
3
0.15
16
4
0.25
12
1
0.08
16
2
0.13
19
0
0.00
416
119
0.29
No. of
ISM deficiency
NKSMC ships
rate
(B)
Per
(A/B)
Total
company
68
17.0
2.9
572
23.8
2.6
715
14.3
3.1
720
8.3
3.6
392
6.0
3.1
175
10.9
1.7
84
7.0
4.8
162
5.4
4.9
278
6.2
6.1
85
4.3
3.5
67
4.2
6.0
57
4.8
1.8
71
4.4
2.8
49
2.6
0.0
3495
8.4
3.4
8
6
4
2
0
14
13
12
Figure 1.2.2 (b)
11
10
9
8
6
5
4
3
2
1
Length of Company’s SMS operation
ISM deficiency rate per length of Company’s SMS operation
6
7
(c) Per country/region in which Company is located
ISM deficiency rate per country/region in which Companies are located is shown in Table 1.2.2(c) ,
together with the numbers of ISM deficiency cases, and in Figure 1.2.2(c).
z
The average ISM deficiency rate of ships under the management of Companies located in
Thailand has increased again to 9.0% from 4.5% in 2006.
z
That of ships under the management of Companies located in Greece has decreased to 5.6%
from 7.4% in 2006.
z
That of ships under the management of those in U.S.A, Malaysia , India, Turkey, Philippine
Singapore, Korea, U.K., and China have increased.
Table 1.2.2(c) ISM deficiency rate per country/region in which company are located
Country/Region
No. of
ISM deficiency
cases
(A)
8
2
4
16
1
4
7
25
3
2
2
57
7
2
2
142
No. of
Companies
5
4
10
77
5
22
19
52
15
6
25
207
23
12
46
528
Thailand
U. S. A.
Malaysia
Greece
India
Turkey
Philippines
Singapore
Korea
U. K.
China
Japan
H.K.(China)
Taiwan
(Others)
Total
No. of
NKSMC ships
(B)
ISM deficiency
rate
(A/B)
89
33
69
287
23
94
174
624
76
57
62
1877
251
109
168
3993
9.0
6.1
5.8
5.6
4.3
4.3
4.0
4.0
3.9
3.5
3.2
3.0
2.8
1.8
1.2
3.6
10
9
8
7
ISM
defic.
rate
(%)
6
5
4
3
2
Figure 1.2.2(c)
Taiwan
H.K., China
Japan
China
U.K.
Korea
Singapore
Philippines
Turkey
India
Greece
Malaysia
U.S.A.
0
Thailand
1
ISM deficiency rate per country/region in which company are located
7
1.2.3
Per port state who carried out PSC inspection
The number of ISM deficiency cases per port state who executed PSC is shown in Table 1.2.3.
The number shown in the Table contains the ISM deficiency case (only one case) of NK Class
ship with SMC issued by the organization other than Class NK
● The number of ISM deficiency cases in U.S.A has greatly increased to 34 cases from 15
cases in 2006.
● The numbers of ISM deficiency cases in Australia, Japan, China, U.K., Korea and
H.K.(China) have fairly decreased from those in 2006.
Table 1.2.3 ISM deficiency case per port state
who executed PSC
Authority
U.S.A.
Australia
Japan
China
U.K.
Belgium
Russia
Canada
Italy
France
Korea
Netherlands
Chile
Spain
Poland
Portugal
H.K..(China)
Argentina
Brazil
Singapore
Germany
(Others)
Total
2004
12
27
30
8
8
1
1
6
6
3
8
9
9
0
3
4
16
151
No. of ISM deficiency cases
2005
2006
2007
5
15
34
29
37
26
14
22
10
3
14
9
9
12
7
4
2
6
0
4
6
1
2
5
7
4
5
3
2
4
1
11
4
4
2
4
3
2
2
2
2
8
1
4
1
1
2
1
0
2
1
2
5
0
11
11
10
96
159
143
8
Chapter 2
ISM deficiencies and PSC actions
2.1 Comparison of ISM deficiencies per ISM Code requirement
The total numbers of ISM deficiencies recorded in PSC reports in 2004 to 2007 and those divided
according to ISM Code requirements, by its sections, are shown in Table 2.1.
Table 2.1 Total No. of ISM deficiencies and distribution per ISM Code requirement
Year
ISM Code requirements (Section No.)
Total
1
2
3
4
5
6
7
8
9
10
11
12
13
99*
2004
2
18
8
0
8
29
24
37
9
88
16
9
2
-
250
2005
3
2
4
0
4
11
16
21
21
68
2
3
0
3
158
2006
5
4
9
3
10
44
19
38
11
109
15
6
8
2
283
2007
1
4
1
2
9
26
32
27
20
92
17
7
3
0
241
99* : The ISM Code requirement with which the deficiencies were raised was not specified.
Section
Requirements for
1
Compliance with mandatory rules, etc. (1.2)
2
Safety and environmental protection policy
3
Company responsibilities and authority
4
Designated persons
5
Master’s responsibility and authority
6
Resources and personnel
7
Development of plans for shipboard operations
8
Emergency preparedness
9
Reports and analysis of non-conformities, accidents and hazardous occurrences
10
Maintenance of the ship and equipment
11
Documentation
12
Company verification, review and evaluation
13
Certification and periodical verification
z
The total number of ISM deficiencies decreased to 241 in 2007 in spite of the increase of ISM
deficiency cases from to 142. The number of ISM deficiencies per ISM deficiency case is 1.7.
z
Percentage of ISM deficiencies related to “maintenance of the ship and equipment” is 38.2%,
and continued largest among those sorted by ISM Code requirements.
z
The percentage of ISM deficiencies related to “resources and personnel” and “emergency
preparedness” decreased from 15.5% to 10.8% and from 13.4% to 11.2% respectively.
z
Contrary the percentage of ISM deficiencies related to “development of plans for shipboard
operations” and “reports and analysis of non-conformities, accidents and hazardous
occurrences” increased from 6.7% to 13.3% and from 3.9% to 8.3% respectively.
9
2.2 Comparison of deficiencies and detention per port state
The numbers of ISM deficiencies and detentions of ship recorded in PSC reports in 2007 per ISM
Code requirements and port state who executed PSC are shown in Table 2.2.1. Those in the
brackets are the numbers of detention.
Table 2.2.1 No. of ISM deficiencies & detention per port state & ISM Code requirements
Authority
U.S.A.
1
1
2
3
Australia
ISM Code requirements (Section No.)
4
5
6
7
8
9
10 11
1
10 14
2
12 18
3
(6) (3)
(4)
1
2
4
5
1
16
1
1
Japan
2
Netherlands
1
Belgium
1
(1)
1
U.K.
1
China
1
1
2
1
1
(1)
4
2
(1)
2
(2)
3
(2)
2
2
(1)
5
2
Total
1
2
(1)
4
(1)
1
2
1
1
Italy
(Others)
3
4
5
3
9
(1)
26
(8)
32
(3)
1
1
11
(2)
27
(7)
2
20
(4)
12
2
1
8
1
4
2
5
(5)
4
(2)
2
1
7
(3)
28
(7)
92
(17)
13
1
2
(1)
2
1
6
(2)
17
(3)
2
2
7
3
Total
63
(13)
31
(0)
17
(0)
16
(3)
14
(7)
13
(6)
12
(0)
10
(3)
65
(12)
241
(44)
( ): Number of detention
z
The largest number of ISM deficiencies was pointed out at PSC inspections carried out in
U.S.A., followed by Australia, Japan, Netherlands, Belgium, U.K., China and Italy.
z
As to the number of ISM deficiencies that were taken as grounds for detention of the ship,
U.S.A. was also the largest followed by Belgium, U.K., Netherlands and Italy.
z
The detainable ISM deficiencies related to “maintenance of the ship and equipment”
numbered 17. It accounted for 40% of all the detainable ones, whereas the percentage of
those related to “resources and personnel” 18% and “emergency preparedness” 16%.
10
2.3 Analysis of deficiencies recorded along with PSC actions applied
The distribution of ISM deficiencies recorded in PSC reports in 2007 per ISM Code requirements
by its sections and PSC actions taken is shown in Table 2.3.1 and the distribution of the same by
ISM Code requirement in Figure 2.3.1.
Table 2.3.1
Distribution of ISM deficiencies per ISM Code requirement and PSC action
10
15
16
17
18
19
30
40
50
70
99
-
Defic. rectified
Defic. to be rectified by
next port
Defic. to be rectified
within 14 days
Defic. to be rectified
before departure
NC to be rectified
within 3 months
MNC to be rectified
Before departure
Grounds for detention
NC to be rectified
within 7 days
Flag state informed
Defic. to be rectified
before back to US port
Others
Blank
ISM
Code
req.
0
No action
PSC Action1)
Total
Sect.
No.
1
1
2
4
2
3
1
1
4
2
1
5
9
6
26
7
32
8
27
9
20
10
92
11
17
12
7
13
3
GT 07
2)
GT 06
1
1
1
4
5
8
3
13
3
4
10
7
1
4
6
4
3
7
36
7
3
2
1
1
1
1
1
3
3
1
1
1
6
3
17
1
1
3
1
2
3
5
2
1
1
3
1
3
2
1
1
1
1
2
3
10
4
1
1
1
1
5
2
1
241
0
3
3
12
30
82
7
44
3
12
17
12
16
283
0
3
2
10
43
138
9
61
0
0
1
5
11
Notes:
1)
The Action Codes are those used under Paris MOU and Tokyo MOU, except “40” and “70” which are used
by USCG. The Action Code “19” is used only by Paris MOU.
2)
Ground total. The data of 2006 were presented for comparison.
140
120
No. 100
80
of
ISM 60
defic.40
20
0
2006
2007
0
10
15
16
17
18
19
30
40
50
70
99
Blank
Action Code
Figure 2.3.1 Distribution of ISM deficiencies per ISM Code requirement
11
Analysis with collected ISM deficiency data, which are summarized in Table 2.3.1, and the
descriptions of ISM deficiencies related to the requirements of ISM Code Sections 6 to 10
recorded in PSC inspection reports along with PSC actions are presented below.
For more information an extract from reports of PSC inspections carried out in Australia, China,
Japan, Korea, India, Brazil, U.S.A., Canada, U.K., French, Italy, Netherlands, Russia and Iran in
2007 is given at the Appendix showing the descriptions of ISM deficiencies together with relevant
deficiencies on ship constructions, equipment, etc.
General
z
Among PSC actions, per Action Code, applied to the ISM deficiencies, the number of the
deficiencies related to “non-conformity to be rectified within 3 months (Action Code 18)” was
82, the largest one which accounted for 34%, followed by those related to “grounds for
detention (Action Code 30)” accounting for 18.3% and those related to “deficiencies to be
rectified before departure (Action Code 17)” accounting for 12.4%.
z
The detainable deficiencies in 2007 decreased to 44 from 61 in 2006.
decreased to 18.3% from 22% in 2006.
ISM Code Section 6
z
The percentage also
Resources and personnel
The ratio of ISM deficiencies related to “resources and personnel” to the whole has been
decreasing. However, requirement for personal understanding of contingency performance,
operation of safety equipment and environment protection equipment and operation of
GMDSS facilities is increasing as well as requirement for quality of ballast water management
system in PSC inspection. These requirements are not only completeness of documents or
records but sometimes extended to observation of personal performance. For example, upon
requirement of demonstrations and comparison with the records and documents, it is reported
that records are not comparable with the actual or unreliable records and documents are
exist.
ISM Code Section 7
Development of plans for shipboard operations
z
In ISM related deficiencies, the ratio of relating ISM Code Sec. 7 was 13.3 %, this number
was the second largest number after the relating ISM Code Sec. 10.
z
The observed deficiency examples are as follows.
(a) BWM (Ballast Water Management) Plan is missing sampling point locations and no
record of tank sediment is being kept.
(b) Crew attempted bunkering operation without C/E who went ashore, which did not comply
with relevant requirements of the ship’s SMS.
(c) Passage /Voyage planning procedures were not updated to include necessary
information.
(d) Ship didn’t make voyage planning for last port based on operation manual.
(e) Shipboard hatch cover maintenance plan did not comply with MSC169(79).
(f) Several documents used to essential shipboard procedures are not in accordance with
the SMS.
ISM Code Section 8
z
Emergency preparedness
The rate of ISM deficiencies related to this element of safety management systems
decreased. However the number of these deficiencies was 27 and 7 out of 27 were treated
under action code 30 “grounds for detention”.
12
z
The deficiencies can be divided into the following three cases as same as those in 2006.
(a) The crew were found unfamiliar with the procedures of abandon ship and/or fire
protection and extinguishing, or operation of lifeboats & launching appliances, or a fixed
fire extinguishing system.
(b) Abandon ship drill and fire drills were not carried out as required, or not recorded properly
if carried out, in particular launching and maneuvering of lifeboats at interval of 3 months.
(c) Serious damages or malfunctioning were found on life-saving appliances, fire
extinguishing systems or communication systems*
* e.g. emergency fire pump, fire damper, F.O. tank shut-down system, MF/HF radio
z
There were not a little deficiencies raised which indicated that the records for drills had not
properly been conducted.
ISM Code Section 9
z
Reports and analysis of non-conformities, accidents and
hazardous occurrences
Typical cases where deficiencies related to the above requirements were pointed out are
as follows.
(a) Malfunctioning of a number of equipments* had not been reported to the Company as
non-conformities.
* e.g. unusable chain controller of windlass, leakage of hydraulic oil pipes, pipe doublers
patches and a large hole on air pipe
(b) Deficiencies recorded in previous PSC inspection reports had not been reported to the
Company in accordance with the SMS procedure.
ISM Code Section 10
Maintenance of the ship and equipment
z
The percentage of PSC actions by the Action Code applied to deficiencies related to the
maintenance was the largest and it accounted for 38% of all the deficiencies which is almost
same as that in 2006.
z
Among the PSC actions by the Action Code mentioned above: “NC to be rectified within 3
months” accounted 39% (49% in 2006), “ground for detention” 18% (23% in 2006) and
“deficiencies to be rectified before departure” 8% (15% in 2006 )
z
Cases where the ISM deficiencies related to maintenance were pointed out can be divided
into the following four:
(a)
A serious damage or malfunctioning of constructions, equipment or systems for safety
or environmental protection* was found
* e.g. lifeboat including engine and release gear & launching appliance, emergency
fire pump and fixed CO2 fire-extinguishing system, hull construction and oily water
separator, fire damper and steering gear.
(b)
Lots of deficiencies were found on construction, equipment, systems or fittings for safety,
environmental protection or crew accommodation.
(c)
Periodical inspection or tests of equipment or systems were not carried out as required
by regulations or the SMS procedures.
* e.g. test of alarm system, checking of batteries
13
(d) Such deficiencies as mentioned above had not been reported to the Company or the
activities of inspection and repairs onboard the ship had not been recorded properly in
accordance with the SMS procedure.
14
Appendix
Extract from PSC inspection reports
An extract from reports of PSC inspections carried out in Australia, China, Japan, Korea, India,
Brazil, U.S.A., Canada, U.K., French, Italy, Netherlands, Russia and Iran in 2007 is given at the
Appendix showing below the descriptions of ISM deficiencies together with relevant deficiencies
on ship constructions, equipment, etc.
1. Australia
ISM
Code
Section
-
Action
Code
30
30
15
99
17
17
17
17
17
17
15
99
12
-
15
18
16
10
18
-
16
16
11
10
15
18
17
30
17
17
17
17
17
15
18
-
30
17
17
17
17
17
-
99
8
18
10
18
-
30
Deficiencies
Emergency fire pump no pressure available for immediate use
Fire Dampers (louvers) for engine room fans stbd aft & port fwd seized open
Load line & draft marks not clearly visible (Stbd)
Garbage record book does not comply with MEPC 116(51) (No cargo residue entries)
AIS navigational status not correct for port location
Voyage plan not in accordance with SOLAS CH. V Reg. 34
Current editions of navigational charts for intended voyage not on board 250, 246 & 818
Emergency generator room not clearly marked ( no IMO symbol)
Emergency lighting numerous not working around accommodation block
Several closing flops seized around accommodation & CO2 room mushroom vent
Sewage treatment unit with low air pressure
Lifeboat embarkation arrangements SOLAS - Lifeboat embarkation arrangements SOLAS Ch
III R.116 not compliant
Pump shutdowns (ESD) - stbd bunkering manifold not operational
No Company Internal audit done in lost twelve months
Instructions for essential maintenance & testing of emergency fire equipment not available ref
(Chapter 2 SOLAS Fire Training Manual)
The above deficiencies are objective evidence that the ISM system does not address sections 8
& 10 of the code
Entries for oil record book not as per IMO resolution MEPC 117/52
Entries for garbage record book in reference to cargo residue discharge not as per IMO
resolution MEPC 116/51
Cargo record book not being maintained
BC Code latest edition not onboard, required for certificate of fitness
Passage plan not as per SOLAS chap. V Reg.34 and bridge procedure guide.
2/2 engine room fire dampers seized
Stairway on aft of accommodation block from bridge deck locked. Key for lock not readily
available
Crew unfamiliar with lifeboat emergency steering
Numerous self closing sounding pipe valves springs removed
Forward liferaft ladder not ready for immediate use. Shackles seized
EPIRB hydrostatic release unit expiry not marked
Water ingress alarm number 3 hold portside sensor only failed
Vessels SMS fails to ensure operational readiness of fire dampers
MF/HF radio defective, not able to transit satisfactory (receiving coast station manual
transmissions).
Emergency fire pump priming pump engaging/disengaging mechanism defective.
Main engine oil mist detector not operational.
Fire detection panel bells and alarms switched off (officers not aware of isolation).
Oily water separator safety valve seized (not operating at designed pressure).
Engine room double bottom tanks sounding pipes self closing device closing springs missing/remo (5 Pieces).
Emergency generator batteries not able to start generator. Battery No.1 & 2 defective from 15
September (Note: Company notified while at anchor 17th September & spare batteries
arranged Newcastle).
The safety management system on board the vessel does not ensure that emergency
equipment such as MF/HF radio, emergency generator, emergency fire pump are ready for
use in an emergency.
The safety management system on board the vessel does not ensure satisfactory maintenance
of MF/HF radio equipment, emerg. Generator batteries, emerg. Fire pump priming pump &
M.E. oil mist detector.
Engine room supply fan fire damper wasted/broken apart
15
10
17
18
Stb'd lifeboat remote brake operating wire incorrectly adjusted to enable remote operation
Safety Management System procedures for testing & determining effective closing of fire
dampers not satisfactory
2.China
ISM
Code
Section
6
6
10
3
Action
Code
17
17
17
17
17
18
16
16
16
16
18
Deficiencies
Fire doors in Accommodation Space clearance found at the bottom frame.
No.1642 N/A, No.1619 need renewed
C/O not familiar with COLREG 1972
3rd officer not familiar with line throwing appliance
No fire extinguisher in workshop
Maintenance of the ship and equipment for lifeboat engine not accordance with SMS
Chart No.342 - Edition not up dated & small correction not up dated
NP 30,31, 32 - Record of amendment not up dated
MARPOL 73/78 - not up dated
IMDG Code - not up dated
The company can not provide latest nautical publication on board for ship
3.Japan
ISM
Code
Section
9
7
Action
Code
30
17
17
17
18
18
10
18
3
9
99
17
17
17
99
17
17
18
18
10
8
17
15
15
18
15
17
18
-
16
Deficiencies
Port Engine Room Ventilator flap was broken (flap was removed from operation spindle due to
corrosion)
Shade plate for starboard side light - not mat black
Funnel fire dampers (port side) not closed completely
Quick closing valve for No.2 D.O. Tank in E/R unable to close due to broken operation wire.
Non-conformity notice based on SMS form 9.2 has not been made since 11-04-2006
Ship didn't make voyage planning last port Chiba to Yokohama based on Vessel Operation
manual (VDM) as per section 1.1.2
Ship didn't carried out monthly check refer deficiency items based on ship's FFA maintenance
plan.
ISSC; not report about gross tonnage
SMC: copy
A-part of insulation in engine room; tore off
Self-closing doors in E/R; belt on opening hook
Not recorded well about not recorded weekly
Explosion proof light in battery room; not turned on
Exhaust pipes; not covered
Company's corrective actions were not taken timely
Not carried out within 3months about PSC inspection at Hachinohe on 20 Dec., 2006 & at
Shimizu on 2 May 2007
Crew members; Not familiar with fire extinguishing system in paint store room
No.2 G/E F.O. injection line; leaked with spray
Emergency fire pump; not enough pressure (delivery pressure: 2.0 Kg/cm2)
Not properly implemented as evidenced by deficiencies (No.2 G/E, Emergency fire pump)
Fire insulation compound for bulkhead; not enough (Capt. Deck, W/H)
Port side lifeboat launching drill (include maneuver); not carried out from May 2007
SMS did not ensure the emergency preparedness as evidence; drill record of 3monthly launching
of L/B- detail was not recorded properly
National contact point list; not up to date
4.Korea
ISM
Code
Section
11
-
Action
Code
16
99
99
16
99
99
Deficiencies
Previous Load Line marking need to be erased
Oil Record Book not updated
SOLAS(2004), MARPOL(2005), IBC(1998) not updated
IAMSAR Manual III not marked on SE Cert.
Address of management company on DOC & CSR Form I not updated
Previous CSR Form I & Form III not on board
16
8
8
-
99
99
99
17
99
99
99
99
30
99
17
99
99
16
99
99
99
Garbage record book not updated and recorded properly
Garbage management plan ship's name incorrect
F/S processing endorsement Cert. for Capt, 2/O, 3/O, C/E expired on 07-03-2007
NAVTEX turned off
Chart not corrected
Passage plan not signed by Capt.
Fire, Abandon, Waterbone boat dril not done this month
Limit S/W for lifeboat launching not working properly
Self sustained air supply system leaking (S/B)
One seat belt stuck inside L/B (S/B)
Safety lanturn not approved stored
Garbage stored outside receptacle
Hyd. Oil leaking on main deck
Crew not familiar with fire drill and boat drill
Q'ty of LSA not marked
Angle indicator of steering gear not clear
Garbage bins made of plastic in Galley
5.India
ISM
Code
Section
-
Action
Code
30
30
10
17
3
-
30
-
30
-
17
17
11
17
17
17
17
Deficiencies
Fire dampers for supply duct in galley & pantry room found frozen, not operational.
Wire mesh on top of galley oven found missing, all clamping/securing bolts for fitting
arrangement found broken.
Safety guard cover for V-belts and pulley on domestic fridge compressor drive found missing.
E/F/P poorly maintained. Crew tired/exhausted while attempting to start(more than 20 min).
Failed during & after inspection.
Discharge of main bilge P/P & sludge P/P found interconnected with lines of OWS in E/R in
violation of MARPOL Regulation.
2 foam extinguishers in E/R could not be discharge satisfactorily. Extinguisher's knob found
seized & broke during test operation.
Engine Room bilges found containing excess amount of oily mixture, suspect oil and water
leaks.
Spare foam extinguishers found inadequate & appeared substandard without any maker's name,
approval marks etc.
Inadequate ventilation observed in Steering Room and Emergency Fire Pump Room.
Form E of SE Cert. does not indicate designation of rescue boat, may be clarified from the class
surveyor.
Immersion suits are not provided for full LSA requirement, only 6 Nos. found on board.
There is no type approval cert.ificate for incinerator and for oily bilge seperator and for 15ppm
monitoring equipment.
6.Brazil
ISM
Code
Section
-
Action
Code
17
17
17
17
17
-
17
-
30
17
17
30
30
-
30
Deficiencies
Draft marks, load lines marks and deck lines are not clear
Hull corrosion condition is very poor
Lifeboats reflective bands are not clear
Air conditioning plant is out of order
Main engine turbocharger is uner repair procedures. Master must present concerning the
subject. The class society must issue a report
Ballast warer reporting form has not been filled according all tanks are representing a density
value as 1.020 and salinity as 28unit6. The ship is authorized to discharge the ballast water into
the Santos Port on such conditions.
The X-band radar is out of order and the transponder could not been tested.
Has a rubber hose connecting the fresh water expansion tank into the engine room to the bilge
Auxiliary engine #3 is defective and could not been tested. The class society must issue a report
Oily water separating system has a pipeline with a valve that allow a connection after to the
overboard discharge line. The class society must issue a report.
Electrical system - There are many electrical wires without protection inside engine room aft part
of main engine offering rist of injury.
Main engine exhaust gas test valve are not fixed on safe order. There are several leakages of
17
-
17
-
30
30
17
11
2
17
30
30
17
17
30
17
30
30
30
fuel oil offering risk of fire
Engine room Port side stairway lower floor is not fixed on safe order
Emergency air compressor can't be tested due fault of a handle bar to be operated
Auxiliary air bottle has rubber hoses to the pressure gauge and as a supply pipeline. The class
society must issue a report.
There are petroleum and chemical products stored inside the steering gear room
EEBDs were not located nor fixed according.
The number of it is not complying the regulations
Emergency fire pump has presented too much leakage through the mechanical seal
Steering gear room communication telephone system with the bridge and over is out of order.
Liferafts reflective bands are missing
2nd engineer sanitary facilities is in poor conditions
Obsolete documents and certificates were maintained on the same file as the new ones.
There's a light by Stbd side with the cover holed by a wire
There's plastic hoses been used for a bilge system
Flushing water pressure is missing to the crew lavatories
There is clear evidence the ship does not substantially comply with the requirements of ISM
Code. Sufficient evidence of violations posing risks to the people and the marine environment
were present, Class society must execute an audit and issue a report about preparedness of the
crew to attend ISM Code
7.U.S.A.
ISM
Code
Section
10
Action
Code
30
10
30
9
30
10
30
30
2
30
-
30
-
30
9
-
30
17
10
17
10
17
10
17a
50a
7
50
50
10
50
-
50
Deficiencies
Soft patches, SW cool line, sewage OVBD, air cooler liine, etc. in E/R; No nonconformity reports
have been submitted to company / no corrective action have been taken. Many repairs have
been in place for an unknown period of time
Although proper checklists exist & were being filled out correctly, based on the condition of the
lifesaving & firefighting appliances listed below, the inspections conducted are questionable.
S side FPT vent in bos'n stores has a large hole. Could cause water to seep from tank into bos'n
stores during ballasting operations. No nonconformity reports have been submitted to company/
DPA.
Electrical equipment throughout ship is in disarray. but, inspection reports by crew indicate
equipment is in good condition. Holes have been drilled through steel Bhd to run wires
Passage/Voyage planning is not being done thoroughly. No tide / current tables are being
maintained
Stb'd #4 TSBT is holed and has been patched by crew. Additional welded inserts have been
installed by the crew without class approval
The Captain of the Port of San Francisco questions the adequancy of the implementation of the
vessel's SMS under the ISM
Garbage is mixed throughout the vessel, including at the final collection point prior to at-sea
disposal. All categories of garbage are mixed together.
Crew is not following Garbage Management Plan. Containers are not color coded properly, and
garbage is not segregated
Some winches; excessive hydraulic leaks, greatly increasing the risk that hydraulic oil will reach
the sea.
Ships air horn / whistle pipe is patched, rendering horn inefficient: No reports have been made to
company / DPA
Anchor (P&S) winch "kick-back bars" used for stripping the anchor chain from the wild cat are
bent, out of alignment, and unusable. No non-conformity reports have been submitted to
company / DPA
Severe wastage was found in the air conditioning room. Inside venting is completely wasted; fire
dampeners would be ineffective during a fire.
With the finding of sea piping and with no reports made to managers
- No.2 M/E salt water cooling pump has soft patch, -No.1 Generator has soft patch on cooling
water out.
- No.1 Generator has soft patch on S.W. cooling in. -No.2 Sea water cooling pump in way of
manifold pipe has soft patch.
- Drain cooler end bell has plastic epoxy repair. - Label high level and overfill tank alarms.
Two (2) large holes found drilled in bulkhead leading to radio room/locker. Fire plan indicates B0
boundary.
Vessel procedures not followed according to Safety Management System: - No track lines
maintained to berth while pilot was on board; no tides and
currents were included in passage plan. no fixes taken for duration of Golden Gate Bridge to
berth.
Hospital inventory is not being maintained properly. Crew cannot find correct medications due to
improper labeling and poor organization.
Sewage not being maintained as per the manufacturer's requirements (Daily, weekly, monthly)
18
2
50
50
-
50
10
6
30
40
70
30
9
50
7
40
3
70c
Semi-annual and annual inspection are not being completed. Sewage manual on board is in
Japanese. Provide manual for crew and chlorine test kit as required
Three (3) doors - aft: port and starboard; one (1) port amidship are wasted. Provides inadequate
fire protection.
Based on the deficiencies listed, the Captain of the Port recommends that an external ISM audit
be conducted within next 30 days.
Should that audit be conducted, fax the report to the Coast Guard at 510-437-3566.
Starboard lifeboat was damaged during drill. Crew repaired the damage section of the lifeboat,
however, the fiber glass repair are pending. Have the repairs done to the satisfaction of class.
There have been no need to repairs noted or logged.
Starboard S/W spool piece has a fiber glass patch on it. This was placed there by the shipyard
personnel. Repair was not reported.
Bilge piping system of oily water separator; by-pass rubber hose was found in E/R.
HP fuel oil supply valve in vicinity No.7 Cyl. of M/E leaking sufficiently to wet insulation blanket
Remote shut off capability was not provided on the E/G FO Tank greater 500L capacity.
Engine department failed to demonstrate proper operation of bilge filtering equipment in
accordance with SMS work instruction, 1st assistant Eng. did not demonstrate proper
alignment of system valves without prompting from PSCOs. Recommend external audit of SMS
procedures for operation of all pollution prevention equipment
Nonconformities & their possible causes are not reported; lagging in CO2 room wasted along
intersection of deck & bulkhead. Chief Engineer did not notify Company
SMS procedures for cargo deck ventilation during cargo work do not ensure personal safety with
regards to entry into hazardous atmospheres. While boarding vessel dockside approximately
one hour after vessel's arrival dockside, PSCOs noted cargo deck ventilation was not operating.
PSCOs personal atmospheric sensors detected CO levels in excess of 45 ppm in cargo hold 7.
Several leaks on ME and MGDE's; insufficient spares (gaskets/seals) on board to correct
condition. The C/E stated that spare parts have been
requested via TELEX message, the company has replied that spare parts will be delivered to the
vessel at next port. Reportedly company will supply these spares at next port. The PSCO has
clear grounds to believe that there's objective evidence that the company needs to address the
supply of
f the suitable amount of consumable parts onboard the vessel.
8.Canada
ISM
Code
Section
6
10
-
Action
Code
30
16
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
17
17
17
18
17
16
18
17
Deficiencies
Closing cleats on hatch access covers missing/seized
Identification & open closed signs missing
Electrical cables, junction boxes not secured
Wooden gratings on bridge rotted & broken many places
Lighting fixtures in accommodation missing covers etc.
Insufficient fruit & vegetables
Insufficient pressure in toilets some not working in cabins
Dirty AC return filter
Hot & cold water, lighting fixtures, heating cooling controls missing or broken
Loose battery in emergency generator room
Paint locker not properly maintained
Canadian notice to mariners not on board
Lifebuoys for man overboard not correct weight
Lifebuoys not as per approved plan, light & rope on same buoy
Oxygen & acetylene cylinders not properly stowed secured
Identification missing on ventilators & remote stop switches
Port lifeboat; window securing bolts missing & window wiper missing
HRU improperly fitted
Weak link not certified
Rating washing machine inoperative
Crew lack familiarization with safety device
Deck cable box corroded, improper repair of failed electrical cables carried out without class
approval .
Missing clamps on cargo hatch CO2 line
Provision crane many defects
Maintenance of ship & equipment not as per SMS
Self closing door in accommodation opening restricted
19
9.U.K.
ISM
Code
Section
-
Action
Code
17
30
-
17
-
17
17
17
17
17
17
17
30
-
17
16
17
17
17
17
17
17
17
17
16
17
17
17
17
17
17
17
17
-
17
17
99
10
10
8
6
17
16
18
30
30
30
Deficiencies
Port Lifeboat embarkation ladder spreaders have rotten
Port Lifeboat; wasted keel foundation bracket & fall block, rotten wooden athwartship, boat
hooks, canopy stanchions, etc.
No.3 H/Cover; stb'd aft stay plating holed. Fwd stb'd foundation plating partly wasted. Fwd stb'd
hydr. Pipe support plating holed & wasted.
Aft Mooring deck starboard winch aft support stays partly wasted.
Shore based maintenance incorrectly filled in wrong equipment listed . No signature on
document
Self closing device for E/R No.3 F.O. tank not working (Spring missing)
Cold rooms, galley & handling room, fridges found dirty
Meat room to be arranged plastic packets removed & all meats segregated.
Emergency Fire Pump Exhaust Lagging on stb'd poop deck wasted.
Stb'd Lifeboat embarkation ladder spreader have rotten.
Stb'd Lifeboat; wasted keel foundation bracket & fall block, rotten wooden athwartship, boat
hooks, fall wire cover, etc.
Five Lifejackets found to heavy rotten stitching.
Hand rail on stb'd lifeboat platform wasted and holed.
No.2 Hatch cover (Port, fwd) corner plating wasted.
Main deck accommodation (Stb'd) watertight door bottom holed and wasted.
Aft mooring deck port winch foundation plating wasted on port side.
Emergency firemen's torch inoperative.
List of call signs too old. (ITU publication)
VHF Radio installation, display unreadable.
MF/HF Radio installation: wrong number program
Funnel fire flaps not closing fully.
Aux engine No.1 & 2 exhaust gas cylinder's thermometers inoperative/ broken
F.O. Purifier inlet quick closing valve found stuck and not working.
Fire hose in E/R bottom plating fwd port found leaking at various place.
Aux boiler pilot burner oil pump coupling guard missing.
Admiralty chart BA 2454 notice to mariners No. 180 not done.
Fire drill have not been performed appropriately as per the SMS.
No records of rest available for crew & officers
First aid box in engine control room has no medicines (eyewash)
Crew mess room plug point with tapes & oil &cadets cabin bed lamp naked, glass protection
cover to be place, danger of electric shocks.
Galley hot plate uptake, slides oily/greasy - fire hazard to be cleaned.
Rotten vegetables found to be removed.
The certificate issued by flag valid until 23-8-2012 full term 5 years shows 'Iinterim certificate' as
heading, to be corrected.
Crew and officers common toilet flush not working
Stb'd ladder, accommodation outside from captains deck to boat deck rotten/holed handrail
Failure to report vessel for mandatory expanded inspection letter
Many deficiencies recorded in this report (over 30 deficiencies) leading to SMS break down.
Sub standard fire drill
Crew must practice drills or be sent on refresher training. Owner to investigate.
10.France
ISM
Code
Section
10
7
8
9
-
Action
Code
18
18
18
18
30
30
17
17
17
Deficiencies
No evidence that monthly critical equipment maintenance have been done from July to
September 2007
Voyage plan not done according to SMS check list & Preparation for arrival in port check list is
not applied according SMS
No evidence that the company has established the annual emergency drill schedule
At the time of inspection the previous Non-Conformities are not available on board.
Emergency fire pump - inoperative, can not been started.
Main Deck Fire Line Holed (aft, Stb'd side No.1 Cargo hold)
E/R Ventilation duct found heavily corroded
F.O. Leakage in way of Heater
20
-
17
17
15
8
10
-
17
16
16
16
16
16
16
15
10
99
Big quantity of garbage retained on board (batteries)
Bitter ends access not possible
FPT sounding pipe caps missing
Excessive waster leakage on sea water service pump to be fixed
Emergency diesel generator - unable to start on batteries (UMS ship)
In meat room - paper lags to be removed (not hygenic)
F/F lifeboat launch 20-11-2007 - not use of the appropriate reporting form (EW FORM
No.D-128)
Person in charge of LSA equipment show lack of familiarity with lifeboat testing
Pressure gauges - missing or inoperative on fire pump No.1 and 2
Camshaft LO pump No.1 - breaker inoperative
Emergency fire pump - not properly maintained, water leakage
Engine room telegraph as required by SOLAS/II - 1/R37 (2 means of communication) is
inoperative (stuck out "Dead Slow")
Maintenance of the ship and equipment - incomplete, above mentioned deficiencies show a
lack of maintenance - Additional external audit is required within 3 months
11.Italy
ISM
Code
Section
-
Action
Code
16
16
17
16
17
-
17
30
30
30
17
-
16
16
16
17
17
17
10
16
16
17
16
17
16
12
16
-
16
16
Deficiencies
CSR document: no. 3 not signed; no. 1 not in original on board
Records of rest and working hrs to be kept for all crewmembers on board (master and C/E
missing).
Galley: filters in stove hood to be cleaned
Stowage of liferafts: aft liferaft does not provide for easy side to side transfer at a single deck
level. Classification society to investigate within 14 days.
There is not evidence of launching appliances / lifeboat on load release gear annual thorough
examination on board
Two fire hoses at aft mooring station to be replaced (found holes).
Emergency fire pump cannot deliver required pressure to the line.
Main fire line found hole in way of cargo hold no. 4 and 5
Funnel fire damper - stb side - at funnel deck does not close
Open/close indication on bridge Dk fire dampers are inverted. E/R(P) damper at funnel Dk: air
leak from flange on air delivery line.
Freeboard marks are not clearly visible
Overall maintenance of hatch covers defective (i.e. cleats, hatch coamings, rubber gaskets,
etc..)
PS winch at fwd mooring station: hydraulic line holed
Boiler safety valves to be clearly marked
Some nautical charts for next intended voyage to be provided: BA 1941- 917 - 1058 - 1976.
Solas convention 2006 amendments / IAMSAR volume III / list of lights vol. E ed. 2007/2008
not available on board.
List of operational contact points - annex II - not available
Oil record book part I to be properly filled in and format to be renewed.
Muster list does not include indication of officer in charge of LSA maintenance/substitutes of
key persons.
garbage management plan: incinerator instructions are not included
Cargo hold n. 3 - water level indicator - sensor failure
Above noted deficiencies denote an improper implementation of ISM instructions as to
maintenance of ship - equipment.
Company is requested to investigate incorrect implementation of ISM procedures and
instruction by carrying out an internal audit within allotted timescale. Class society to carry out
an additional audit as per flag state requirements.
International Ship Security Certificate: intermediate verification not recorded.
International Tonnage Certificate: date on which keel was laid is incorrect
12.Netherlands
ISM
Code
Section
-
Action
Code
17
-
17
-
17
Deficiencies
No manometer for Oxygen bottles (welding equipment). No warning sign "No Smoking,
No.open fire, etc.” near Oxygen and Acetylene store
No manometer for oxygen bottles (welding equipment), No warning sign "No Smoking, No
open fire, etc." near oxygen and acetylene store.
Incorrect; categories don not correspond with categories mentioned in MARPOL
21
7
2
17
17
17
18
18
2
18
-
17
17
17
17
-
17
17
17
17
17
17
17
17
17
17
-
17
6
5
8
17
30
30
30
7
18
7
7
18
18
No evidence of 5 yearly dynamic load test of davits
Oil Record Book not properly filled in wrong code used.
Not corrected, e.g. table 4 contains incinerator & communicator, grinder, etc.
Section 4, part 8, Form SP8D4, "Rescue Centers" data for the Netherlands incorrect.
Crew is not equipped with all personal safety equipment; safety shoes, safety helmet etc.
Safety policy is not fully implemented
Non compliance with mandatory international requirements with regard to 2000/59/EC (waste
notification not properly filled in)
No evidence of weekly moving lifeboats from stowage position
Emergency lighting batteries in poor condition. Batteries for GMDSS not properly stowed.
(loose)
Embarkation light port side inoperative.
Nozzle of fire hose on aft deck missing, fire hose used during testing of emerge. fire pump in
poor condition.
Light of lifebuoy on embarkation deck stb'd side not connected to the lifebuoy.
One EEBD used for demonstration (now to low press). No training EEBD available.
Pressure of Breathing Apparatus air bottles on aft deck too low
Crew not familiar with BA set, fireman's outfit, face mask.
Filling pipe of Aft peak tank kept open.
Crew not familiar with collision bulkhead valve.
Crew has absolute no knowledge about the CO2 system and manual/remote control.
SOLAS training manual and fire safety operational booklet not ship specific.
Safety valve for overpressure inoperative.
Oil water separator has been used in Mediterranean sea (special area) while not fitted with
alarm and sopping device.
Enclosed space entry not proper format. No identification of space to be entered, no data
mentioned for validity.
Oxygen meter not properly calibrated, reading in open air 22% oxygen.
No proper familiarization for Captain and Chief Engineer. (no familiarization Form filled in).
Captain is not aware and able to identify his overriding authority in the ISM Manual.
C/E is not familiar with CO2 system, crew cannot show proper handling of Fireman's outfit,
etc.; Emergency preparedness too low
Abandon ship drill is not mentioned monthly, but 3 monthly lowering of lifeboats to water level
is not mentioned
Crew list format; not in compliance with the IMO regulation and not compliant with the crew list
in use.
Enclosed space entry permit format is incomplete, item 17 & 18 are identical, no validity date,
space supposed to be entered not mentioned.
13.Russia
ISM
Code
Section
10
-
Action
Code
17
17
17
17
17
17
17
15
16
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
Deficiencies
Foundation for electric cables to signaling lighting in poor condition
Indicator's of position for bunkering system are missing
Freeboard marks (LL mark) to be painted
Outside emergency lighting some of deep corroded
Lighting in engine room to be repaired cover's
Hydraulic pipe's for hatch cover's some in poor condition
Monitor operation panel in engine room poor condition
IMO symbols are partly missing (detectors, etc.)
Outside doors to be marked
ISSC address of company to be corrected
Cargo hold hydraulic cylinder heavy leak of hydr. Oil
Vent. Funnel of cargo hold's some of head's deformed
Emergency fire pump heavy start
Vent. Pipe of D.G. (case) deep corroded
Vent. Pipe of H.F.O. tank fire protective screen some of damaged
Bilge-Ballast system in engine room handles not available
Por side gangway some of parts deep corroded
Stb'd side gangway gear foundation deep corroded
Engine control room panel ramp's some of no light
Mooring ropes to be used in good condition
IMO symbols to be indicated according fire plan
Fire detectors to be maintained
Deviation card duration (ship after dry docking)
Exchange ballast plan density are salinity)
22
10
-
17
17
17
Ultrasonic report no on board (thickness measurement record)
Lifeboat's retro reflector, Type renewed
Navigation bridge window damaged
14.Iran
ISM
Code
Section
10
8
3
-
Action
Code
17
17
30
17
30
30
30
17
17
30
17
30
17
30
17
30
30
30
17
17
17
17
30
17
17
17
17
17
30
30
17
17
30
17
30
30
30
17
30
17
30
30
17
30
30
30
30
Deficiencies
There is not safe access between the ship and terminal
F.O. tank line heavily rusted
Lifeboat means of recovery defective
F.O. save-all holed in several part
M/E No.4 unit high pressure FO line is leaking & defective
E/R self-closing control cocks is defective & FO ones tied in open position
Fire hazard in E/R due to excess accumulation oil in bilge & etc.
Some of generator gauge defective
No.3 Generator diesel engine is leaking
Oil water separator is defective
Boiler insulation defective
L.O. glass gauge valve is defective
E/R muster list is missing
Purifier for Aux. engine quick closing valve inoperative
Lifeboat fall date of end to end over due
Evidence of pollution both on deck & ship's over board
Maintenance of ship & equipment do not comply with SMS. Objective evidence mention the
deficiencies
Ship is not ready for emergency preparedness
Load line marks painting faded
Insufficient No. of Immersion suits on board
MSDS was not on board
SOPEP contact point is not up to date
Accommodation ventilation damper chocked
Numerous fire door in open position with hold back hook
All (NP77) was not corrected up to date
Radar performance is in poor condition (ARPA)
Data was not correctly entered in radio log book (Sart, EPIRB, 2 way Radio, Section B)
GMDSS emergency light burnt out
INMARSAT C is defective
HF SSB & VHF DSC do not work with DC power
Navigation light panel lights burnt out
Numerous vent without marking
E/R Mushroom ventilation seized open
Lifeboat shears & block corroded
E/R sky light holed
Accommodation fire damper seized closed
Galley intake sky light holed & heavily corroded
Liferaft marking is missing
SMS internal audit report is missing (from 2005)
Port lifeboat thwart rotten
Provision store air vent corroded & holed
Steering gear room air vent holed & corroded
FW air vent head cover is defective
Port lifeboat cracked & broken
Chemical ventilation (TK) wasted & holed
Absence of oil spill equipment beside manifold during cargo operation
Deck foam line heavily rusted & mid-ship valve seized
23
Key Contacts
Head Office Information Center
Safety Management Systems Department
Nippon Kaiji Kyokai
1-8-5, Ohnodai, Midori-ku, Chiba
Tel: +81-43-294-5999 Fax:+81-43-294-7206
E-mail: smd@classnk.or.jp
Overseas Offices
South Asia and Oceania
Singapore Office
Nippon Kaiji Kyokai
101, Cecil Street,
#21-01 Tong Eng Building,
Singapore, 069533
Tel: +65-62223133,
Fax: +65-62255942
E-mail: sp@classnk.or.jp
Middle East, East Mediterranean
and Black Sea
Piraeus Office
Nippon Kaiji Kyokai
39-41 Akti Posidonos,
Moschato 183 44,
Piraeus, Greece
Tel: +30-21-09420020,
Fax: +30-21-09420079
E-mail: pr@classnk.or.jp
Europe and Africa
London Office
Nippon Kaiji Kyokai
6th Floor, Finsbury Circus House,
12-15 Finsbury Circus,
London, EC2M 7EB,
United Kingdom
Tel: +44-20-7621-0963,
Fax: +44-20-7626-0383
E-mail: ln@classnk.or.jp
The Americas
New York office
Nippon Kaiji Kyokai
One Parker Plaza, 11th Floor
400 Kelby Street, Fort Lee,
N.J. 07024, U.S.A.
Tel: +1-201-944-8021,
Fax: +1-201-944-8183
E-mail: ny@classnk.or.jp
For more information on this publication, please contact the
Safety Management Systems Department
1-8-5, Ohnodai, Midori-ku, Chiba 267-0056, Japan
TEL:+81-43-294-5999 FAX:+81-43-294-7206 e-mail: smd@classnk.or.jp
http://www.classnk.or.jp
Download