Eaton® MSDI Class I & II/Cat D & C, Three Phase Surge Diverter The MSDI surge diverter is designed to provide point-of-entry protection against power surges caused by external sources such as lightning strikes & substation switching. Common-mode protection is available for sites remote from the M.E.N. point including industrial sites & rooftops in multi-storey buildings. An ideal device for all Category locations. The MSDI surge diverters utilise MOV protection for both differential & common-mode protection. Multiple MOV devices are used in parallel for primary circuit redundancy. The status of protective devices is continuously monitored & displayed using LED bar-graph indicators. All MOV devices are thermally fused & isolated by ceramic fuses. Shunt Surge Diverter, 3 Phase 200kA Typical applications: • All Power Circuits including "Point-of-Entry" • Telecommunications Systems & Rectifiers • Process & Control Systems & UPS Systems • Computer & Medical Systems • Multi-storey buildings • All sensitive Electronic Equipment MSDI unit is provided with an alarm relay. The alarm function provides a summary alarm output for protection degradation as well as power failure. The alarm may be configured to indicate either partial or total protection failure. The level of protection remaining is indicated by LED bar-graph indicators on the front panel. A summary alarm relay contacts provide remote signalling to remote equipment. Key Features: • 3 Mode, 2 Stage Surge Diverter • Surge suppression rating of 200kA • Enclosed in IP24 cabinet • LED Bargraph display on each phase • Protection Fail Alarm Relay • 5 Year Warranty Surge Category The MSDI is suitable for use in category locations: Class II/Cat D (6kV/30KA) Point of Entry, High Exposure Class II/Cat C (6kV/15kA) Point of Entry/ Service Entrance www.eaton.com/powerquality www.eatonelectric.com.au Eaton® MSDI Specifications Technical Specifications MSD200CM60i Input voltage 200 - 250VAC (380 - 440VAC 3 Phase) Maximum continuous voltage (MCOV) 320VAC Temporary overvoltage - TOV 350VAC, 15 mins Service type TT, TN, TN C-S or any 3-phase system with a grounded neutral Energy Absorption rating - per mode (Joules) Primary Protection L-N = 3,000J/ph, 9,000J total Common mode protection L-E = 710J/ph, 2,130J total Common mode protection N-E = 2,130J total Aggregate rating 13,260J Recommended max. overcurrent protection 125A GL HRC fuse Protection modes Line-Neutral, Line-Earth, Neutral-Earth In 8/20us (Line-Neutral) Nom. surge life 75kA per phase x 20 times In 8/20us (Line-Earth) Nom. surge life 15kA per phase x 20 times In 8/20us (Neutral-Earth) Nom. surge life 45kA x 20 times Ismax 8/20us (Line-Neutral) Max. surge life 200kA Ismax 8/20us (Line-Earth) Max. surge life 40kA Ismax 8/20us (Neutral-Earth) Max. surge life 120kA Initial clamp voltage (Line-Neutral) 560V (350Vac RMS) Initial clamp voltage (Line-Earth) 680V (420Vac RMS) Initial clamp voltage (Neutral-Earth) 680V (420Vac RMS) Internal protection (fusing) All surge diverter connections are fused via HRC fuses to IEC269-2-1 Alarms/indicators Bargraph display for protection remaining, dry contact alarm relay output – 250Vac/32Vdc, 10A, 4kV isolation, Alarm under-voltage cutoff 180Vac. Enclosure rating IP24 Design Standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D,E AS1768-2007 Cat B,C,D,E AS3000, AS3100, CE mark Dimensions & Weight 370 x 160 x 560 mm (W x D x H), 14kg Environment -10 to 65°C, 10 to 90%RH (non-condensing) Due to continual product improvement specifications are subject to change without notice. Copyright 2010 Eaton Corporation. C M Y CM 2 4 3 D Differential protection. One phase shown, all phases identical LINE t is to be us ed in c onjunc tion with T O LOADS FPRI C t cables phys ically s eparated at all times. nce 500mm. red to MC B s for connection to main S W B . ation guide for details . within 3m (cable length) of the main s ystem k for point-of-entry application. G reater ction. per operation of this MS D it is es s ential that ly s hort earth connection be made to the ith reference to local wiring standards, ally s ized agains t a thermal rating, ted fault currents , (5,000 to 25,000 amps). S D however, the ins taller mus t be aware an exceed 50,000 amps, and therefore nerally required to limit voltage drops ns . T o achieve these requirements, the ld be s elected to be equal to, or greater ming cable into the MS D. T his ensures that earth cable are minimis ed. er-carrying conductors s hall be sized pplicable s tandards . It is recommended utral conductor be s ized the same as (or e conducts as it is the primary return for MY D Diverter Ins tallation G uide vs s Doc #510065) connections via 8mm bolts . M8 s tud, lower right of enclos ure. connection points . e earth cable, even if the unit is bolted to CY K Min distance to ceiling 300mm 550192_msdi_cnx_dia_a4.pdf 6/10/2008 1:30:27 PM 1 S urge Diverter c tion Diagram CMY C M Y CM MY K CY CMY Connection & Line Diagram C L-N protection INP UT L3 L2 L1 F US E N E E AR T H S T UD ON C AS E 8mm NEUTRAL L3 N-E protection L2 Min distance to floor 600mm L1 L-E protection NO Protection alarm B NC EARTH STUD MAIN S W B Common-mode protection. One phase shown, all phases identical < 3m line distance Important: Before installing the device, please read & follow the installation & operation instructions. 2/23/2005 2/23/2005 LC MAIN E AR T HING P OINT (S W B ) FROM OTHER PHASES Title A Size A4 Date: File: MS Di S eries 550192 B COM NE UT R AL LINK OR M.E .N. 1 2 A MSD LINE DIAGRAM Number Revision 550250 7-Aug-2006 Shee1 t of1 JDP C:\tvss engineering\Product_engineering\current\MSF\MSF.ddb Drawn By: 3 Eaton Low Voltage Surge Protection - Australia & new Zealand 1300 3 EATON (1300 3 332 866) www.eaton.com/powerquality www.eatonelectric.com.au 4 0