BD 2412EN ALUMINIUM BIDIRECTIONAL SOUND PROJECTOR DESCRIPTION Bidirectional sound projector with double loudspeaker, characterized by high acoustic performance, excellent design and compact dimensions. The BD 2412EN is ideal for train stations, underground stations, car parks, factories, warehouses, corridors and PA systems in general. MAIN APPLICATIONS • • • • • • • MAIN FEATURES Voice evacuation system Schools Shopping malls Hospital Museums Hotels Office building • • • • • SPECIFICATIONS Type: Transducers: Sensitivity (1 W, 1 m): Max. sound pressure (20 W, 1 m): Max. sound pressure (20 W, 4 m): Frequency response (–10 dB): Dispersion: Power taps (100 V): Input impedance: Enclosure material: Use: IP grade: Dimensions (without bracket): Colour: Net weight: bidirectional sound projector 2 x 5” 89 dB 102 dB 90 dB 130 Hz ÷ 20 kHz 130° (1 kHz), 50° (4 kHz) 20 – 10 – 5 W 500 Ω – 1 kΩ – 2 kΩ aluminium alloy indoor – outdoor IP 66 Ø 146 mm, 184 mm light grey 3.3 kg Bidirectional sound projector with double loudspeaker, characterized by high acoustic performance, excellent design and compact dimensions Complying with EN54-24 standard thanks to ceramic termination block, thermal fuse and internal fire-resistant cable IP 55 protection, suitable for outdoor use It’s idea for train stations, underground stations, car parks, factories, warehouses, and PA systems in general Continuous nominal power: 20/10/5 W ([100 V] BD 2412EN Beamwidth vs. Frequency Response 120 360 Horizontal Beamwidth (1/3 Octave) Vertical Beamwidth (1/3 Octave) 330 300 110 Coverage Angle (Deg.) 270 dB SPL 100 90 240 210 180 150 120 90 80 60 30 70 20 BD 2412EN 100 1000 Frequency (Hz) 0 100 10000 Directivity Index and Q 1000 Frequency (Hz) 10000 Normalized Horizontal off-axis Response 100 20 5 18 0 16 -5 8 6 -10 -15 -20 4 2 1 100 1000 Frequency (Hz) 10000 0 -25 0 0 -5 -5 -10 -10 -15 -15 -30 100 10000 Attenuation in dB 5 -25 1000 Frequency (Hz) Normalized Vertical off-axis Response. Below the box Normalized Vertical off-axis Response. Above the box -20 Horizontal ±10 degrees Horizontal ±20 degrees Horizontal ±30 degrees Horizontal ±40 degrees Horizontal ±50 degrees Horizontal ±60 degrees -30 100 5 Attenuation in dB Total Q 10 Directivity index Di, dB 12 10 Attenuation in dB 14 -20 Vertical +10 degrees Vertical +20 degrees Vertical +30 degrees Vertical +40 degrees Vertical +50 degrees Vertical +60 degrees -25 1000 Frequency (Hz) 10000 -30 100 Vertical -10 degrees Vertical -20 degrees Vertical -30 degrees Vertical -40 degrees Vertical -50 degrees Vertical -60 degrees 1000 Frequency (Hz) 10000 BD 2412EN HORIZONTAL 1/3 POLAR PLOT Horizontal 1/3 Octave Polars 315 250 200 0° 330° 30° 0 -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 270° 90° 0 150° -6 -12 -18 -24 -30 -36 -42 -48 2500 2000 1600 0° 30° Horizontal 1/3 Octave Polars 60° -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 240° 270° 0 150° 210° 5000 4000 3150 Horizontal 1/3 Octave Polars -48 -42 -36 -30 -24 -18 -12 -6 270° 0 -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 90° 0 120° 150° 210° 150° 210° 60° 240° 120° 180° 30° 300° 90° 0 10000 8000 6300 0° 330° 60° 240° 120° 150° 180° 30° -6 -12 -18 -24 -30 -36 -42 -48 90° 0 120° 210° 300° 90° 0 -48 -42 -36 -30 -24 -18 -12 -6 240° 0° 330° 60° -6 -12 -18 -24 -30 -36 -42 -48 0 150° 210° 300° 0 270° 90° 0 30° 300° 180° 330° 270° -48 -42 -36 -30 -24 -18 -12 -6 1250 1000 800 0° 330° 120° 180° Horizontal 1/3 Octave Polars Horizontal 1/3 Octave Polars 60° 240° 120° 210° 30° 300° 0 240° 630 500 400 0° 330° 60° 300° 270° Horizontal 1/3 Octave Polars 180° 180° VERTICAL 1/3 POLAR PLOT Vertical 1/3 Octave Polars 315 250 200 90° 120° 60° 150° 180° 0 Vertical 1/3 Octave Polars 30° -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 0 210° 180° 0° 0 -6 -12 -18 -24 -30 -36 -42 -48 2500 2000 1600 60° 0 Vertical 1/3 Octave Polars 30° -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 210° 0 330° 300° 240° 270° 180° 0° 0 30° -6 -12 -18 -24 -30 -36 -42 -48 180° 0 5000 4000 3150 90° 60° -48 -42 -36 -30 -24 -18 -12 -6 210° 0 330° 300° 240° 270° 0° 300° 270° Vertical 1/3 Octave Polars 10000 8000 6300 90° 120° 60° 150° 30° -6 -12 -18 -24 -30 -36 -42 -48 0 330° 240° 150° 0° -48 -42 -36 -30 -24 -18 -12 -6 210° 300° 120° 60° 150° 270° 150° 180° 0 1250 1000 800 90° 120° 330° 240° 90° 120° -48 -42 -36 -30 -24 -18 -12 -6 210° 300° Vertical 1/3 Octave Polars 30° 270° Vertical 1/3 Octave Polars 60° 150° 330° 240° 630 500 400 90° 120° 0° 180° 0 30° -6 -12 -18 -24 -30 -36 -42 -48 -48 -42 -36 -30 -24 -18 -12 -6 210° 0 330° 300° 240° 270° 0° PART NUMBERS 1.0-J-E BD 2412EN POWER SELECTION Connect the positive wire (100 V) to the loudspeaker input corresponding to the chosen power rate among 20W – 10W – 5W. Connect the negative wire (0) to the COM loudspeaker input. If connecting to a 70 V line, all power rates will be halved (10 – 5 – 2.5 W). ENGLISH 131.33.074 DIMENSIONS - The loudspeaker cable shall have wires with a suitable section (twisted, if possible, to reduce inductive effects due to surrounding electro-magnetic fields) and are a sufficient electrical insulation. The greater the distance between (All data in mm) the amplifier and the speaker, the larger the connection cable cross-section should be to limit the voltage loss along the line. Connect the positive wire (100 V) to the loudspeaker input corresponding to the chosen power rate among 20W – 10W – 5W. Connect the negative wire (0) to the COM loudspeaker input. If connecting to a 70 V line, 100all power rates will be halved (10 – 5 – 2.5 W). 150 COM 20W 10W 5W 0 100 V NOTES: 146 - The loudspeaker input voltage (Vd) shall correspond to the amplifier output voltage (Va). 175 - The sum of nominal power values (Pd x n) of all loudspeakers connected to 186 the line shall not exceed the amplifier power (Pa). AMPLIFIER Pa > Pd x n Va Vd=Va Pa = Amplifier power INSTALLATION NOTES Pd = Speaker power Ensure the support surface (walls, ceilings,ofetc.) has the necessary mechanical n = Number speakers characteristics to support theVdweight of theinput loudspeaker. = Speaker voltage Make connections as described the dedicated Va =inAmplifier outputmanual voltage section. Vd=Va Vd=Va CERTIFICATIONS AND APPROVALS • EN 54-24:2008 compliant To ensure a correct musical reproduction, loudspeaker phase is to be respected (loudspeakers are connected respecting the amplifier polarity). To prevent inductive effects from causing hum, noise and a bad system working, loudspeaker lines should not be laid together with other electric cables (mains), microphone or line level signal cables connected to amplifier EARTHING inputs. In theboth innerindoors side of and the mounting BD 2412EN can be installed outdoors.bracket, there is a screw (M3 x 6) to earth the loudspeaker with a suitable earth wire. 6 RCF products are continually improved. All specifications are therefore subject to change without notice. www.rcf.it