BD 2412EN

advertisement
BD 2412EN
ALUMINIUM BIDIRECTIONAL SOUND PROJECTOR
DESCRIPTION
Bidirectional sound projector with double loudspeaker, characterized by high
acoustic performance, excellent design and compact dimensions. The BD
2412EN is ideal for train stations, underground stations, car parks, factories,
warehouses, corridors and PA systems in general.
MAIN APPLICATIONS
•
•
•
•
•
•
•
MAIN FEATURES
Voice evacuation system
Schools
Shopping malls
Hospital
Museums
Hotels
Office building
•
•
•
•
•
SPECIFICATIONS
Type:
Transducers:
Sensitivity (1 W, 1 m):
Max. sound pressure (20 W, 1 m):
Max. sound pressure (20 W, 4 m):
Frequency response (–10 dB):
Dispersion:
Power taps (100 V):
Input impedance:
Enclosure material:
Use:
IP grade:
Dimensions (without bracket):
Colour:
Net weight:
bidirectional sound projector
2 x 5”
89 dB
102 dB
90 dB
130 Hz ÷ 20 kHz
130° (1 kHz), 50° (4 kHz)
20 – 10 – 5 W
500 Ω – 1 kΩ – 2 kΩ
aluminium alloy
indoor – outdoor
IP 66
Ø 146 mm, 184 mm
light grey
3.3 kg
Bidirectional sound projector with double loudspeaker, characterized by high acoustic performance, excellent design and compact dimensions
Complying with EN54-24 standard thanks to ceramic termination block, thermal fuse and internal fire-resistant cable
IP 55 protection, suitable for outdoor use
It’s idea for train stations, underground stations, car parks, factories, warehouses, and PA systems in general
Continuous nominal power: 20/10/5 W ([100 V]
BD 2412EN
Beamwidth vs. Frequency
Response
120
360
Horizontal Beamwidth (1/3 Octave)
Vertical Beamwidth (1/3 Octave)
330
300
110
Coverage Angle (Deg.)
270
dB SPL
100
90
240
210
180
150
120
90
80
60
30
70
20
BD 2412EN
100
1000
Frequency (Hz)
0
100
10000
Directivity Index and Q
1000
Frequency (Hz)
10000
Normalized Horizontal off-axis Response
100
20
5
18
0
16
-5
8
6
-10
-15
-20
4
2
1
100
1000
Frequency (Hz)
10000
0
-25
0
0
-5
-5
-10
-10
-15
-15
-30
100
10000
Attenuation in dB
5
-25
1000
Frequency (Hz)
Normalized Vertical off-axis Response. Below the box
Normalized Vertical off-axis Response. Above the box
-20
Horizontal ±10 degrees
Horizontal ±20 degrees
Horizontal ±30 degrees
Horizontal ±40 degrees
Horizontal ±50 degrees
Horizontal ±60 degrees
-30
100
5
Attenuation in dB
Total Q
10
Directivity index Di, dB
12
10
Attenuation in dB
14
-20
Vertical +10 degrees
Vertical +20 degrees
Vertical +30 degrees
Vertical +40 degrees
Vertical +50 degrees
Vertical +60 degrees
-25
1000
Frequency (Hz)
10000
-30
100
Vertical -10 degrees
Vertical -20 degrees
Vertical -30 degrees
Vertical -40 degrees
Vertical -50 degrees
Vertical -60 degrees
1000
Frequency (Hz)
10000
BD 2412EN
HORIZONTAL 1/3 POLAR PLOT
Horizontal 1/3 Octave Polars
315
250
200
0°
330°
30°
0
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
270°
90°
0
150°
-6 -12 -18 -24 -30 -36 -42 -48
2500
2000
1600
0°
30°
Horizontal 1/3 Octave Polars
60°
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
240°
270°
0
150°
210°
5000
4000
3150
Horizontal 1/3 Octave Polars
-48 -42 -36 -30 -24 -18 -12 -6
270°
0
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
90°
0
120°
150°
210°
150°
210°
60°
240°
120°
180°
30°
300°
90°
0
10000
8000
6300
0°
330°
60°
240°
120°
150°
180°
30°
-6 -12 -18 -24 -30 -36 -42 -48
90°
0
120°
210°
300°
90°
0
-48 -42 -36 -30 -24 -18 -12 -6
240°
0°
330°
60°
-6 -12 -18 -24 -30 -36 -42 -48
0
150°
210°
300°
0
270°
90°
0
30°
300°
180°
330°
270°
-48 -42 -36 -30 -24 -18 -12 -6
1250
1000
800
0°
330°
120°
180°
Horizontal 1/3 Octave Polars
Horizontal 1/3 Octave Polars
60°
240°
120°
210°
30°
300°
0
240°
630
500
400
0°
330°
60°
300°
270°
Horizontal 1/3 Octave Polars
180°
180°
VERTICAL 1/3 POLAR PLOT
Vertical 1/3 Octave Polars
315
250
200
90°
120°
60°
150°
180°
0
Vertical 1/3 Octave Polars
30°
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
0
210°
180°
0°
0
-6 -12 -18 -24 -30 -36 -42 -48
2500
2000
1600
60°
0
Vertical 1/3 Octave Polars
30°
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
210°
0
330°
300°
240°
270°
180°
0°
0
30°
-6 -12 -18 -24 -30 -36 -42 -48
180°
0
5000
4000
3150
90°
60°
-48 -42 -36 -30 -24 -18 -12 -6
210°
0
330°
300°
240°
270°
0°
300°
270°
Vertical 1/3 Octave Polars
10000
8000
6300
90°
120°
60°
150°
30°
-6 -12 -18 -24 -30 -36 -42 -48
0
330°
240°
150°
0°
-48 -42 -36 -30 -24 -18 -12 -6
210°
300°
120°
60°
150°
270°
150°
180°
0
1250
1000
800
90°
120°
330°
240°
90°
120°
-48 -42 -36 -30 -24 -18 -12 -6
210°
300°
Vertical 1/3 Octave Polars
30°
270°
Vertical 1/3 Octave Polars
60°
150°
330°
240°
630
500
400
90°
120°
0°
180°
0
30°
-6 -12 -18 -24 -30 -36 -42 -48
-48 -42 -36 -30 -24 -18 -12 -6
210°
0
330°
300°
240°
270°
0°
PART NUMBERS
1.0-J-E
BD 2412EN
POWER SELECTION
Connect the positive wire (100 V) to the loudspeaker input corresponding to
the chosen power rate among 20W – 10W – 5W. Connect the negative wire
(0) to the COM loudspeaker input.
If connecting to a 70 V line, all power rates will be halved (10 – 5 – 2.5 W).
ENGLISH
131.33.074
DIMENSIONS
- The loudspeaker cable shall have wires with a suitable section (twisted, if
possible, to reduce inductive effects due to surrounding electro-magnetic
fields)
and are
a sufficient
electrical insulation. The greater the distance between
(All
data
in mm)
the amplifier and the speaker, the larger the connection cable cross-section
should be to limit the voltage loss along the line.
Connect the positive wire (100 V) to the loudspeaker input corresponding to
the chosen power rate among 20W – 10W – 5W.
Connect the negative wire (0) to the COM loudspeaker input.
If connecting to a 70 V line,
100all power rates will be halved (10 – 5 – 2.5 W).
150
COM
20W 10W 5W
0
100 V
NOTES:
146
- The loudspeaker input voltage (Vd) shall correspond to the amplifier output
voltage (Va).
175
- The sum of nominal power values (Pd x n) of all loudspeakers connected to
186
the line shall not exceed
the amplifier power (Pa).
AMPLIFIER
Pa > Pd x n
Va
Vd=Va
Pa = Amplifier power
INSTALLATION NOTES
Pd = Speaker power
Ensure the support surface (walls,
ceilings,ofetc.)
has the necessary mechanical
n = Number
speakers
characteristics to support theVdweight
of theinput
loudspeaker.
= Speaker
voltage
Make connections as described
the dedicated
Va =inAmplifier
outputmanual
voltage section.
Vd=Va
Vd=Va
CERTIFICATIONS AND APPROVALS
• EN 54-24:2008 compliant
To ensure a correct musical reproduction, loudspeaker phase is to be
respected (loudspeakers are connected respecting the amplifier polarity).
To prevent inductive effects from causing hum, noise and a bad system
working, loudspeaker lines should not be laid together with other electric
cables (mains), microphone or line level signal cables connected to amplifier
EARTHING
inputs.
In theboth
innerindoors
side of and
the mounting
BD 2412EN can be installed
outdoors.bracket, there is a screw (M3 x 6) to earth
the loudspeaker with a suitable earth wire.
6
RCF products are continually improved. All specifications are therefore subject to change without notice.
www.rcf.it
Download