IP65 - Beghelli

advertisement
Emergency Lighting
Symbols and approvals
TR
Technologically advanced products, designed
with a view to energy saving, recycling at the
end of their working life, and reduced wear of
parts during use.
IP65
Protection Grade against external factors
(According to CEI EN 60598-1)
Self-powered fixtures without diagnosis
IP40
IP65
The highest Protection Grade is obtained by
installing a kit to be ordered separately on the fixture
SE Version
Indicates Resistance Temperature of the product to
the incandescent wire test (CEI EN 60598-1)
SA Version
PS Version
AT
AR
LG
Self-powered fixtures with local diagnosis,
AUTOTEST series
IK09
Self-powered fixtures with local diagnosis,
AUTORIPARA series
Self-powered fixtures with diagnosis and remote
control, LOGICA series
Protection Grade against impact of the fixture
complying with test methods (According to EN 50102)
Fixture with a photosensor allowing activation of
the fixture in SA mode automatically as soon as
the threshold of environment light is lowered
RM Version
Emergency fixtures for non permanent
lighting
Emergency fixtures for permanent
lighting
Fixtures with reduced permanent lighting
(Public Performance)
Series of emergency fixtures with possibility
of excluding the emergency by remote
control (Rest-Mode)
Fixtures with class II insulation level. Fixtures
without this symbol are to be considered class I.
Products with extended 4-year guarantee on all parts,
battery included. For the application
procedures, see the general terms of sale.
12 HOURS
RECHARGE
Emergency lighting fixtures that ensure 1
hour of autonomy after 12h recharging
Fixtures that ensure precise illumination (Lx) on the work
surface, if mounted as indicated in the icon.
LGFM
Self-powered fixtures with diagnosis and
remote control via radio, LOGICA FM series
UV
Fixtures characterized by particular resistance
to UV radiation, suitable for direct exposure
to natural light
SLG
Centralized safety system and fixtures of the
SoccorLogica series.
CIVIL
Fixtures particularly indicated for installations in
homes and small commercial premises
SLGS
Centralized low-voltage safety system and fixtures
of the SICURO 24 series
* for availability contact the Beghelli sales network
ARCHITECTURAL
Fixtures particularly indicated for installations in
luxury Hotels, designer stores, historic buildings,
museums, showrooms, management centres
HT
Centrally powered emergency lighting products with
supply voltage SA/DC
TERTIARY AND INDUSTRIAL
Fixtures particularly suited for installations in Schools,
Hospitals, Public Bodies, hotels and accommodation
facilities, offices, industrial facilities
H 2.5 m
Devices complying with European Community
directives
European quality mark
Italian safety mark
H3m
H6m
H6m
H6m
SDCM - Standard Deviation Colour Matching is the
standard deviation of the correspondence of colours
between two lamps. With a value of 3 SDCM or less, the
lamps emit light with a colour that is difficult to perceive
with the human eye.
TR
Technologically advanced products, designed
with a view to energy saving, recycling at the
end of their working life, and reduced wear of
parts during use.
IP65
Protection Grade against external factors
(According to CEI EN 60598-1)
Self-powered fixtures without diagnosis
IP40
IP65
The highest Protection Grade is obtained by
installing a kit to be ordered separately on the fixture
UV-OIL
Fixtures with particular resistance to UV radiation and
aggression by mineral oils
850°C
Indicates Resistance Temperature of the product to
the incandescent wire test (CEI EN 60598-1)
SE Version
SA Version
PS Version
AT
AR
LG
LGFM
Self-powered fixtures with local diagnosis,
AUTOTEST series
IK09
Self-powered fixtures with local diagnosis,
AUTORIPARA series
Self-powered fixtures with diagnosis and remote
control, LOGICA series
Self-powered fixtures with diagnosis and
remote control via radio, LOGICA FM series
Protection Grade against impact of the fixture
complying with test methods (According to EN 50102)
Fixtures with class II insulation level. Fixtures
without this symbol are to be considered class I.
12 HOURS
RECHARGE
UV
Emergency lighting fixtures that ensure 1
hour of autonomy after 12h recharging
Fixtures characterized by particular resistance
to UV radiation, suitable for direct exposure
to natural light
Fixture with a photosensor allowing activation of
the fixture in SA mode automatically as soon as
the threshold of environment light is lowered
Fixture suitable for safety signs according to UNI EN 1838.
DV (visibility distance): see dimensions table in the
TECHNICAL DATA SHEETS.
L80B20 indicator of product flux maintenance. It specifically
indicates that, within the number of hours specified on the product
data sheet, 80% of the number of LEDs will not lose more than 20%
of the flux.
The number of hours specified on the product data sheet refers to
the most critical product, therefore in conditions of lower power and
at a working temperature lower than 25°C a substantial increase of
the product performance may be expected.
SLG
Centralized safety system and fixtures of the
SoccorLogica series.
CIVIL
Fixtures particularly indicated for installations in
homes and small commercial premises
Devices complying with European Community
directives
SLGS
Centralized low-voltage safety system and fixtures
of the SICURO 24 series
* for availability contact the Beghelli sales network
ARCHITECTURAL
Fixtures particularly indicated for installations in
luxury Hotels, designer stores, historic buildings,
museums, showrooms, management centres
Fixture intended for use with a risk of explosion due to the
presence of combustible powders or explosive
substances according to the ATEX Directive
HT
Centrally powered emergency lighting products with
supply voltage SA/DC
TERTIARY AND INDUSTRIAL
Fixtures particularly suited for installations in Schools,
Hospitals, Public Bodies, hotels and accommodation
facilities, offices, industrial facilities
European quality mark
Italian safety mark
RM Version
Emergency fixtures for non permanent
lighting
Emergency fixtures for permanent
lighting
Fixtures with reduced permanent lighting
(Public Performance)
Series of emergency fixtures with possibility
of excluding the emergency by remote
control (Rest-Mode)
Products with extended 4-year guarantee on all parts,
battery included. For the application
procedures, see the general terms of sale.
Fixtures that ensure precise illumination (Lx) on the work
surface, if mounted as indicated in the icon.
H 2.5 m
H3m
H6m
H6m
H6m
SDCM - Standard Deviation Colour Matching is the
standard deviation of the correspondence of colours
between two lamps. With a value of 3 SDCM or less, the
lamps emit light with a colour that is difficult to perceive
with the human eye.
Contents
Luminaires in the emergency world
. . . . . . . . . . . . . . . . . . . . . . . . .3
Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Technical Annex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
AT - Autotest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
AR - Autotest Ripara . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
LGFM - Logica FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
LG - Logica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
SLGS - Soccorlogica Sicuro 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
SLG - Sicuro Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Examples of mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
The Academy for professionals . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Photometric diagrams and Luce Utile . . . . . . . . . . . . . . . . . . . . . .152
Analytical indices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
1
The highly technological identity and the value of the Beghelli
brand are completely reflected in this project for the renewal of
light sources for emergency and now also illumination devices.
The use of high-efficiency LED and a calibrated light beam in the
Stella Polare project creates appropriate lighting with very high
energy savings.
The Useful Lighting philosophy was born from the need to
achieve a light beam that was suitable for general and
emergency lighting with the highest degree of effectiveness.
The optics were especially designed to resolve the problem of
ground-level lighting with the smallest number of devices, in line
with the requisites of current regulations.
Useful Light Project
It does not matter how much light a device emits.
What the light shows is what matters,
and makes it a useful lighting device.
All the light in excess of the controlled beam is
just a waste of energy.
We are proud to present a new concept of lighting and emergency
lighting that surpasses the limits of simple product innovation and
represents a significant advance in the sector.
We are certain that all the industry players including designers,
architects, wholesalers and installers will value the innovative spirit
of the “Stella Polare” and will be inspired to promote its advantages
to industry reps and clients with the ultimate goal of improving the
quality of life.
Gian Pietro Beghell
For Beghelli “Stella Polare” represents a decisive advance in the
emergency lighting sector, the management of luminous flux and
in terms of the “intelligence” of safety lighting systems.
Professionals in this sector will be granted the ideal tools to
integrate technology and safety procedures, in line with the spirit
with which the UNI CEI mixed Working Group, that I have the
pleasure of coordinating, developed the UNI CEI 11222
Regulation.
Fabio Pedrazzi
2
The lamp guide
in the world of
Emergency Lighting
10h
Overtime
Autonomy
10h
The intelligent devices in the Stella
Polare LED range have an autonomy
time that can be adjusted from 1 to
3 hours. After the imposed autonomy
time has passed, the Overtime function
allows consumption of the residual
power and maintains the device in
operational mode for 10 hours after
blackout by modulating the luminous
flux that progressively decreases.
4-year guarantee
Our product quality allows us to offer a
4-year complete guarantee on all
parts, including the battery
Fast
installation
Simple and effective solutions that can
reduce installation times
Design and range
Our designs meets every aesthetic
and architectural requirement, with
the most extensive range in the LED
emergency lighting world.
Ecology
and energy
savings
All the devices are made with
extremely high quality materials that
are completely recyclable.
The LED system can also offer
significant energy savings.
Intelligence
We have planned the most important
range of control systems to guarantee
operation over time.
AT, LG, LGFM, SLG and SLGS
conform to the requisites of UNI 11222
3
Sistemi Tracking and control systems: description of Systems and fixture compatibility
4
TR
AT / AR
LG / AR
SLGS
SLG
HT
SELFCONTAINED
EMERGENCY
LUMINAIRES
AND EMERGENCY
LUMINAIRES WITH
BATTERY CHECK
SELF TEST
EMERGENCY
LUMINAIRES
SELFCONTAINED
EMERGENCY
LUMINAIRES WITH
CENTRAL
MONITORING
SYSTEM
SOCCORLOGICA
SICURO 24V
SLAVE LUMINAIRES
FOR CENTRAL
BATTERY SYSTEM
MAINS
LUMINAIRES
pag. 130
pag. 130
pag. 139
pag. 140
Emergency lighting
LOGICA LED
pag. 6
STEEL LED EMERGENCY LIGHTING
pag. 12
IP65
FORMULA 65 LED GRANLUCE
pag. 18
IP65
UP LED LITE
page 44
FORMULA 65 LED EXTREME
pag. 26
LED EMERGENCY MODULE
page 82
FORMULA 65 LED CAPACITOR
pag. 32
LUNGLARGALUCE LED - recessed
page 56
LED Module with emergency conversion kits
IP65
IP65
IP43
IP42
UP LED MULTI
page 50
IP40
IP65
T5 LED GRANLUCE
pag. 38
IP42
LUNGLARGALUCE LED - ceiling
page 62
IP65
GRANLUCE LED
page 70
Emergency conversion kits
IP20
IP40
IP40
ECOLED INVERTER MODULE
page 86
PLUG&LIGHT INVERTER
pag. 92
IP40
IP65
IP40
INVERTER LED
page 98
INVERTER LED IP40 IP65
page 99
Exit signs
IP40
IP41
IP40
IP41
IP40
IP41
New
INDICA LED 20
page 104
INDICA LED 30
page 112
UP LED EXIT LITE
page 121
Emergency
Systems
5
EMERGENCY FIXTURES
IP66
IP65
6
Logica LED
EMERGENCY FIXTURES
The
technological
future
wall, ceiling, recessed, false ceiling
of centralised emergency
The perfect technological
expression of LED
emergency lighting.
A housing specially studied to
guarantee Protection degree IP65,
made to a modern, rational design.
A fixing system with a rapid bracket,
to ensure simple
and fast installation.
In the Logica LED, particular care
was devoted to the study of the
louvre: with the aid of optical design
software of the latest generation,
the particular features of LED
lighting have been optimised,
achieving a minimal geometric
shape that nevertheless allows
total control of light reflections.
The maximum of performance
both in terms of average flux and
uniformity and size of lighting.
7
logica leD
LED Emergency
General
characteristics
Equivalent power* 8, 11, 24 W
Power supply 230Vac ± 10% 50/60Hz
Operation Non Permanent (SE), Permanent or
Public Performance (SA/PS)
Control gear Electronic control gear PF≥0,92
Standard EN 60598-1, EN 60598-2-2, EN
60598-2-22, UNI EN 1838, UNI 11222,
EN 62034
Protection degree IP65
This emergency lighting fixture is characterised by particularly
sophisticated electronic technology. Logica LED is the only
emergency lighting fixture, supplied in a centralised version (LG,
LGFM), which configures automatically in an Autotest version (AT) if
not connected to a control unit.
The circuit also allows the fixture to be customised to suit the
necessities of use, adjusting its autonomy (1h/2h/3h, up to 6h for the
8W version) and, in the case of the SA mantained version, it can be
switched to a PS version, adjusting the light intensity according to the
requirements of the type of public establishment. The latter opportunity
is a winner when the safety sign becomes the only visible element. It
must therefore be immediately identifiable, elegant, non invasive and
uniform in all fixtures.
Thanks to the symmetry and extreme uniformity of lighting that
characterise the Logica LED, it can be installed, without a predefined
orientation, on the wall, on the ceiling and recessed using the kit
provided, complete with box and a frame that covers the wires.
Inside the housing is a louvre with dual reflection, which in turn
contains two series of highly efficient LEDs that ensure unprecedented
technical lighting output (up to 1500lm). The highly transparent
polycarbonate diffuser has been designed to seal the optics and
obtain Protection degree IP65.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Autonomy 1h, 2h, 3h,up to 6h for the 8W version
(settable with DIP switch)
IP65 LG SLG HT
Working temperature 0°C ÷ +40°C
230V
50Hz
Mountings wall, ceiling, recessed, false ceiling
UV
Housing Grey polycarbonate, RAL 7035
850°C
12 HOURS
RECHARGE
Optics Symmetrical, metallized antiglare
polycarbonate
* Indicative power for comparison with fluorescent tube fixtures
B
8
11
24
L
• Dimensions (mm) •
B
H
L1
B1
406 147
406 147
406 147
63
63
63
440 170
440 170
440 170
H1
Diffuser visibility (DV)
distance
10
10
10
20
20
20
B1
** Indicative power for comparison with fluorescent tube fixtures
Accessories
Description
12198
12199
12175
12176
12177
Logica Cable Gland
Recessed box with frame to cover the wires
Rapid wall fixing bracket
Logica right diffuser
exclusively for SA/PS versions
Logica left diffuser
exclusively for SA/PS versions
Logica down diffuser
exclusively for SA/PS versions
Order Code
Description
12194
12193
12175
12176
12177
Logica lamp louvre
Logica false ceiling bracket
Logica RIGHT diffuser
Logica LEFT diffuser
Logica DOWN diffuser
8
H
L1
supplied
Order Code
Accessories
L
170
Power**
W
H1
LOGICA METAL GRID
to be ordered separately
12194 Logica metal grid
to be ordered separately
WALL MOUNTING WITH RAPID BRACKET AND SPIRIT LEVEL
MOUNTING ON A PLASTERBOARD FALSE CEILING
Drilling jig supplied: 414x150 mm
12199 Rapid wall fixing bracket
supplied
12193 Logica false ceiling bracket
LOGICA DIFFUSERS
EMERGENCY FIXTURES
RECESSED MOUNTING
to be ordered separately
Recess hole: 430 x 165 mm
12198 LOGICA IP65 recessed box
supplied
12175 Logica PS RIGHT diffuser
12176 Logica PS LEFT diffuser
12177 Logica PS DOWN diffuser
to be ordered separately
to be ordered separately
to be ordered separately
LG (AT if not connected to a Control unit)
W
Order Code
8
8
11
11
24
24
24
24
12182
LOG LED LG 8W SE 1/2/3P
12185
LOG LED LG 8W SA/PS 1/2/3N
12183
LOG LED LG 11W SE 1/2/3P
12186
LOG LED LG 11W SA/PS 1/2/3N
12184
LOG LED LG 24W SE 1/2/3P
LOG LED LG 24W SA/PS 1/2/3N
12187
12184S LOG LED LG 24W SE 1/2/3P S
12187S LOG LED LG 24W SA/PS 1/2/3N S
Description
Logica
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption w
SE
SA/PS
SE
SA/PS
SE
SA/PS
SE
SA/PS
2/4/6h
2/4/6h
1,5/3/4h
1,5/3/4h
1/2/3h
1/2/3h
1/2/3h
1/2/3h
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
NiMh 7.2V 4Ah
NiMh 7.2V 4Ah
30
30
30
30
30
30
30
30
750/450/350
750/450/350
900/550/450
900/550/450
1100/750/550
1100/750/550
1500/900/700
1500/900/700
400
500
600
750
4
4/8
4
4/10
6
6/14
6
6/15
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
2/4/6h
2/4/6h
1,5/3/4h
1,5/3/4h
1/2/3h
1/2/3h
1/2/3h
1/2/3h
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
Pb 6V 4Ah
NiMh 7.2V 2.5Ah
NiMh 7.2V 4Ah
NiMh 7.2V 4Ah
30
30
30
30
30
30
30
30
750/450/350
750/450/350
900/550/450
900/550/450
1100/750/550
1100/750/550
1500/900/700
1500/900/700
400
500
600
750
5
5/9
5
5/15
7
7/15
7
7/16
Weight kg Packaging
-
6
6
6
6
6
6
6
6
* Minimum flux guaranteed according to EN 60598-2-22
LGFM (AT if not connected to a Control unit)
W
Order Code
8
8
11
11
24
24
24
24
12182FM
12185FM
12183FM
12186FM
12184FM
12187FM
LOG LED LGFM 8W SE 1/2/3P
LOG LED LGFM 8W SA/PS 1/2/3N
LOG LED LGFM 11W SE 1/2/3P
LOG LED LGFM 11W SA/PS 1/2/3N
LOG LED LGFM 24W SE 1/2/3P
LOG LED LGFM 24W SA/PS 1/2/3N
12184FMS
LOG LED LGFM 24W SE 1/2/3P S
12187FMS LOG LED LGFM 24W SA/PS 1/2/3N S
W
Order Code
8
11
24
17303
17304
17305
W
Order Code
8
11
24
17403
17404
17405
Description
Logica FM
Version Autonomy
SE
SA/PS
SE
SA/PS
SE
SA/PS
SE
SA/PS
SLG
Weight kg Packaging
-
6
6
6
6
6
6
6
6
Soccorlogica
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
LOGICALED SLG 8W
LOGICALED SLG 11W
LOGICALED SLG 24W
-
-
-
30
30
30
400
500
1000
400
500
1000
3
6
11
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
LOGICALED HT 8W
LOGICALED HT 11W
LOGICALED HT 24W
-
-
-
30
30
30
400
500
1000
400
500
1000
3
6
11
HT
Weight kg Packaging
-
6
6
6
Mains voltage power supply
Weight kg Packaging
-
6
6
6
* Minimum flux guaranteed according to EN 60598-2-22
9
Mounting in a complex architectural field,
wall mounting of the most performing
fixture in the safety lighting category.
10
11
EMERGENCY FIXTURES
12
Acciaio Emergenza LED
LED technology
strong and intelligent
for the highest-level of lighting
EMERGENCY FIXTURES
Incredible performance for LED
emergency lighting in service and
industrial contexts. With a luminous
flux of 1600lm, controlled by a 4-cell
anti-glare aluminum reflector, Acciaio
Emergenza LED has no comparison.
The strong structure comes from the
combination of technological
materials such as Steel,
Technopolymer and Micro-prismatic
tempered glass that create a device
suitable for installation in demanding
contexts as reflected in the ATEX
certification and the IK09 and IP65
protection degrees.
In addition, the Ice Pack system is
easily integrated in the device for
installation in extreme
conditions,assuring correct
functioning over time at temperatures
of even -40°.
CONFORMS TO
ATEX 94/9/EC DIRECTIVE
FOR ZONES 2 AND 2
with accessories to be ordered
separately
13
acciaio emergenza leD
Emergency ceiling light
10h
General
ICE PACK
1600
lumen
characteristics
ATEX
Equivalent power* 24
Autonomy 1h, 2h, 3h
Operation Permanent (SA), Non-permanent (SE)
Rest Mode: with optional control device
(cod. 12101)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, EN 1838, UNI 11222,
ATEX 2014/34
ATEX Classification II 3 G Ex nA II B T135,
II 3 D Ex tD A22 T85
Protection level
Protection
from knocks
Environmental
temp. SE
Environmental
temp. SA
Temp. with
ICE PACK
Installations
Body
Acciaio Emergenza LED is the answer to the need for high technology
products for particularly demanding high risk contexts. The steel body
and the glass shield offer excellent mechanical strength (IK09) and
protection against aggressive chemical agents. In the industrial
context, it is perfect for installations in explosive atmosphere spaces
created by alterations in gassy substances and the presence of airsuspended combustible powder (pursuant to ATEX 94/9/EC
regulation for zones 02 and 22).
The optical system consists of a reflector that is subdivided in 4 cells for
excellent light distribution and a special micro-prismatic glass with
extremely high light transmission for greater visual comfort.
Acciaio Emergenza LED is suitable for use in demanding contexts
including outside environments that are directly exposed to the
elements. It is designed to resist mechanical vibrations and
electromagnetic disturbances that are typical of industrial
environments. The special steel brackets allow the device to be
positioned as required. A compatible accessory, ordered separately,
warms the battery and permits installation in sites with temperatures
as low as -40°C.
You can add a separate AUTORIPARA battery to increase the
luminous flux to 1600 lm.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
IP66
IK09
IP66 IK09
10h
12 HOUR
0 ÷ +50 °C
RECHARGING
850°C
UV
0 ÷ +40 °C
-40 ÷ +50 °C (+40°C SA Model)
wall, ceiling, suspension, electric rail
RAL 7035 polyester powder coated
steel sheet
Heads Tecnopolymer PC+PBT
Optic Anti-glare aluminum diffusing
Shield tempered micro-prismatic
high transmission (3mm) glass
* Equivalent power for comparison with florescent tube devices
Power**
W
L
24. 24s
477
• Size (mm) •
B
H
108
Weight
max kg
98.5
3.2
* Equivalent power for comparison with florescent tube devices
SUSPENSION INSTALLATION
EILING INSTALLATION
Accessories
Code Name
Description
-
Positionable brackets for wall installation
Accessories
WALL INSTALLATION
14
INSTALLATION ON ELECTRIFIED RAIL
Code Order
Description
19046
RA02
12101
Ice Pack Battery
AutoRipara System NiMH 7.2v 1.7Ah
Remote control (RM inhibit function)
supplied
to be ordered separately
LOW TEMPERATURE INSTALLATION WITH ICE PACK
Battery temperature alignment
based on environmental temperature
°C
40°
Battery temperature
30°
20°
10°
Temperature
inside device
0°
-10°
Ice Pack
19046
-20°
Environmental temperature
EMERGENCY FIXTURES
Accessory to maintain warm battery temperature
even in working contexts with very low temperatures
(-40°C). Ice Pack is controlled through a electronic circuit
that is able to maintain a constant battery temperature.
The absorption of the Ice Pack depends on the
environmental temperature.
With Ta=-40°C Pmax= 6w
-30°
-40°
to be ordered separately
Polar diagram
Diagramma
polare
AUTORIPARA SYSTEM
AUTORIPARA SYSTEM:
Inserting the Autoripara Battery, the device
doubles the power or autonomy, and
intervenes in the case of malfunctioning of
the main battery
AUTORIPARA BATTERY INVERTER 7.2V 1.7Ah
RA02
to be ordered separately
Standard optic
LG
Logica
W*
Cod. Order
24
15030
Description
Model
Autonomy
Battery
Average flow
SE (lm)
ACC EM LED 24 LG SE/SA 123H
SE/SA
1h/2h/3h
NiMh 7.2V 1.2Ah
400/275/200
Average flux AR
SE (lm)
Average flow
SA l(m)
220
LGFM
Pack
single
1
Logica FM
W*
Cod. Order
24
15031
Description
Model
Autonomy
Battery
Average flow
SE (lm)
Average flux AR
SE (lm)
ACC EM LED 24 LG SE/SA 123H
SE/SA
1h/2h/3h
NiMh 7.2V 1.2Ah
400/275/200
Average flux AR
SE (lm)
1600/800/550
Average flow
SA l(m)
220
LG AR
Pack
single
1
Logica
W*
Cod. Order
24
15032
Description
Model
Autonomy
Battery
Average flow
SE (lm)
ACC EM LED 24 LGAR SE 123H S
SE
1h/2h/3h
NiMh 7.2V 1.7Ah
800/400/270
Average flow
SA l(m)
Pack
single
1
LGFM AR
Logica FM
W*
Cod. Order
24
15033 ACC EM LED 24 LGARFM SE 123H S
Description
Model
Autonomy
Battery
Average flow
SE (lm)
Average flux AR
SE (lm)
SE
1h/2h/3h
NiMh 7.2V 1.7Ah
800/400/270
1600/800/550
Average flow
SA l(m)
Pack
single
1
* Equivalent power for comparison with florescent tube devices
Contact the Beghelli sales network for SLG, SLGS and HT models
15
Installation in contexts subject to the
ATEX94/9/EC DIRECTIVE as well as the
elevated height of installation demand top
class light engineering performance.
The installation of the ICE PACK accessory
completes the safety profile for mountain
areas or those subjected to low winter
temperatures.
16
17
EMERGENCY FIXTURES
18
Formula65 LED
EMERGENCY FIXTURES
Design and versatility
recessed, wall
for multiple applications
The expression of Beghelli creativity
inspired by energy saving
offer solutions for every
installation context.
Protection level IP65,
innovative LED technology
distinguished by high efficiency
combined
with a latest generation reflector,
Formula 65 LED
represents the ultimate frontier
of emergency lighting.
The range includes the Granluce
model with elevated luminous flux,
Extreme with special accessories
for installation in extreme
temperature environments, the
Capacitor powered by
Supercapacitors rather than
batteries to ensure charging in a
few minutes even in severe
temperatures. All with the elegance
and the Design for which
Formula65 LED is famous.
19
Formula 65 leD ar Granluce
Emergency LED GRANLUCE
Device for emergency lighting that is highly flexible in use. The
symmetry and the great uniformity of its illumination means that
Formula 65 LED AR can be installed without a pre-fixed positioning,
to the walls, ceiling, suspended or recessed.
The white polycarbonate body houses a double-reflective optic that in
turn integrates two highly efficient LED series (greater than
160 lumen/Watt). The high-transparent polycarbonate shield was
designed to seal in the optic group so that the device offers a IP65
protection level. The external shell features a number of pre-scored
access points for direct fitting on all the most common junction or
flush-mounted boxes.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
General
10h
800
lumen
characteristics
12 HOUR
IP RECHARGING
IP65 IK07
10h
Equivalent power* 6, 8, 11, 24
PLUG
H
HOSPITAL
Operation Permanent (SA), Non-permanent (SE)
Rest Mode: with optional control device
(cod. 2730)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, EN 62034
850°C
UV
L
H
Protection level IP65
Protection IK07
from knocks
H1
B
Autonomy 1h, 2h, 3h
Environmental temp. 0°C ÷ +40°
Installations recessed, wall, ceiling, false ceiling,
suspended wall, suspended ceiling
Body Polycarbonate, white RAL 9003
Optic symmetrical, white
Shield Transparent polycarbonate
* Equivalent power for comparison with florescent tube devices
AutoRipara accessories
Code Order
Description
RA01
RA03
AutoRipara Battery System (NiMH 3.6V 1.2Ah)
AutoRipara Battery SYstem (NiMH 3.6V 1.7Ah)
Power**
W
L
6
8
11
24
354
354
354
354
• Size (mm) •
B
H
152
152
152
152
48.5
48.5
48.5
48.5
H1
26
26
26
26
VISIBILITY DISTANCE (VD)
SUSPENDED
WALL
25
25
25
25
m
m
m
m
28
28
28
28
m
m
m
m
* Equivalent power for comparison with florescent tube devices
supplied
AUTORIPARA SYSTEM
Inserting the Autoripara Battery, the device doubles the power or
autonomy, and intervenes in the case of malfunctioning of the main
battery
Accessories
supplied
Accessories
to be ordered separately
Code Order
Description
Code Order
Description
19044
Coupling Formula 65
Adapter tube 16/20 White
ADES SX DX BS F65 (only for SA models)
19040
19041
19045
19042
19043
19044
FLUSH-MOUNTED BOX + FRAMES F65
CEILING BRACKET F65
WALL BRACKET SUSPENDED F65
DOUBLE SIDED SCREEN WITH LEFT/RIGHT ARROWS F65
DOUBLE SIDED SCREEN WITH DOWN ARROWS F65
ADES SX DX BS F65
20
AT
AutoTest
Code Order
6
19220
19221
19222
19223
19224
19225
19226
19227
19228
19229
19230
19231
19232
19233
6
8
8
8
8
11
11
11
11
24
24
24
24
Average flux
SA l(m)
Abs. max
(W)
Description
Model
Autonomy
Battery
n° LED
F65 LED 6W IP65 AT SE 1N/RM
F65 LED 6W IP65 AT SE 3H/RM
F65 LED 8W IP65 AT SE 1N/RM
F65 LED 8W IP65 AT SE 3H/RM
F65 LED 8W IP65 AT SA 1N/RM
F65 LED 8W IP65 AT SA 3H/RM
F65 LED 11W IP65 AT SE 1N/RM
F65 LED 11W IP65 AT SE 3H/RM
F65 LED 11W IP65 AT SA 1N/RM
F65 LED 11W IP65 AT SA 3H/RM
F65 LED 24W IP65 AT SE 1N/RM
F65 LED 24W IP65 AT SE 3H/RM
F65 LED 24W IP65 AT SA 1N/RM
F65 LED 24W IP65 AT SA 3H/RM
SE
SE
SE
SE
SA
SA
SE
SE
SA
SA
SE
SE
SA
SE
1h
3h
1h
3h
1h
3h
1h
3h
1h
3h
1h
3h
1h
3h
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
12
12
12
12
12
12
12
12
12
12
12
12
12
12
78
78
270
270
270
270
390
390
390
390
550
550
550
550
250
280
280
280
280
280
-
1.5
1.5
4.5
1.5
5.0
1.5
5.0
1.5
5.0
1.5
5.0
1.5
5.0
1.5
Average flux AR
SE (lm)
Average flux
SA l(m)
Abs. max
(W)
AT-AR
0.4
0.4
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Code Order
Description
8 R0818 F65LED 8W IP65 ATRIPARA SE123H
11 R1124 F65LED11W IP65 ATRIPARA SE123H
11 R1124SA F65LED11W IP65 ATRIPARA SA123H
24 R2436 F65LED24W IP65 ATRIPARA SE123H
24 R2436SA F65LED24W IP65 ATRIPARA SA123H
Model
Autonomy
Battery
n° LED
Average flux
SE (lm)
SE
SE
SA
SE
SA
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
12
12
12
12
12
135/95/78
180/125/90
180/125/90
315/220/160
315/220/160
250/175/125
315/220/160
315/220/160
550/385/275
550/385/275
250
280
1.5
1.5
4.5
1.5
5.0
Average flux AR
SE (lm)
Average flux
SA l(m)
Abs. max
(W)
LG-AR
Code Order
Description
19234
F65 LED 8W IP65 LG SE 1/2/3H
19235
F65 LED 8W IP65 LG SA 1/2/3H
11 19236 F65 LED 11W IP65 LG SE 1/2/3H
11 19237 F65 LED 11W IP65 LG SA 1/2/3H
24 19238 F65 LED 24W IP65 LG SE 1/2/3H
24 19239 F65 LED 24W IP65 LG SA 1/2/3H
2 19246 F65 LED 24W IP65 LG AR SE 1/2/3H S
24 19247 F65 LED 24W IP65 LG AR SA 1/2/3H S
8
8
Model
Autonomy
Battery
n° LED
Average flux
SE (lm)
SE
SA
SE
SA
SE
SA
SE
SA
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
2xNiMH 3.6V 1.7Ah
2xNiMH 3.6V 1.7Ah
12
12
12
12
12
12
22
22
135/95/78
135/95/78
180/125/90
180/125/90
315/220/160
315/220/160
400/200/140
400/200/140
250/175/125
250/175/125
315/220/160
315/220/160
550/385/275
550/385/275
800/400/270
800/400/270
210
250
280
280
1.5
4
1.5
4.5
1.5
5.0
1.5
4.5
Average flux AR
SE (lm)
Average flux
SA l(m)
Abs. max
(W)
250/175/125
250/175/125
315/220/160
315/220/160
550/385/275
550/385/275
800/400/270
800/400/270
210
250
280
280
1.5
4
1,5
4.5
1.5
5.0
1.5
5.0
LGFM-AR
W
Description
Model
Autonomy
Battery
n° LED
Average flux
SE (lm)
F65 LED 8W IP65 LGFM SE 1/2/3H
F65 LED 8W IP65 LGFM SA 1/2/3H
F65 LED 11W IP65 LGFM SE 1/2/3H
F65 LED 11W IP65 LGFM SA 1/2/3H
F65 LED 24W IP65 LGFM SE 1/2/3H
F65 LED 24W IP65 LGFM SA 1/2/3H
F65 LED 24W IP65 LGFM AR SE 1/2/3H S
F65 LED 24W IP65 LGFM AR SA 1/2/3H S
SE
SA
SE
SA
SE
SA
SE
SA
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
1-2-3h
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiCd 3.6V 0.75Ah *
NiMH 3.6V 1.2Ah *
NiMH 3.6V 1.2Ah *
2xNiMH 3.6V 1.7Ah
2xNiMH 3.6V 1.7Ah
12
12
12
12
12
12
22
22
135/95/78
135/95/78
180/125/90
180/125/90
315/220/160
315/220/160
400/200/140
400/200/140
Code Order
19240
19241
11 19242
11 19243
24 19244
24 19245
2 19248
24 19249
8
NEW
0.4
0.4
0.6
0.6
0.6
1/12
1/12
1/12
1/12
1/12
Weight
Pack
kg single/multi
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.6
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
Logica FM Ripara
8
NEW
Weight
Pack
kg single/multi
Logica Ripara
W
NEW
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
AutoTest Ripara
W
NEW
Weight
Pack
kg single/multi
SLG
Weight
Pack
kg single/multi
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.6
1/12
1/12
1/12
1/12
1/12
1/12
1/12
1/12
Soccorlogica
W Code Order
17364
11 17365
24 17366
8
Description
n° LED
Average flow (lm)
AC/DC (W)
Weight kg
Pack single/multiple
F65 LED 8W IP65 SLG
F65 LED 11W IP65 SLG
F65 LED 24W IP65 SLG
12
12
12
270
390
550
5
6
8
0.8
0.8
0.8
1/12
1/12
1/12
HT
Power supply from mains voltage
W Code Order
17435
11 17436
24 17437
8
Description
n° LED
Average flow (lm)
Weight kg
Pack single/multiple
F65 LED 8W IP65 HT
F65 LED 11W IP65 HT
F65 LED 24W IP65 HT
12
12
12
270
390
550
0.8
0.8
0.8
1/12
1/12
1/12
SLGS
Soccorlogica Sicuro 24V
W Cod. Order
24
Description
17367 F65 LED 24W IP65 SLGS 24V
n° LED
Average flow (lm)
Weight kg
Pack single/multiple
12
340
0.8
1/12
* these products are equipped with an autoripara battery NiMh 3.6V 1.2Ah
21
EMERGENCY FIXTURES
W
Average flux
SE (lm)
accessories
WALL INSTALLATION WITH SPIRIT LEVEL
WALL INSTALLATION
CABLE GLAND Formula 65
-
RECESSED INSTALLATION
RECESSED INSTALLATION ON FALSE CEILING
Recess hole: 370 x 130 mm
19040
Flush-mounted box + frames F65
supplied
19041
Ceiling bracket F65
to be ordered separately
CABLE BRACKET
-
22
cable gland PG16/PG20
supplied
-
3 IP cable grommets
supplied
RECESSED INTO FALSE CEILING
19041
19042
19043
Ceiling bracket F65
double sided screen with left/right arrows
Shield suspended with Down arrows
EMERGENCY FIXTURES
CABLE GROMMETS
ON WALL INSTALLATION
to be ordered separately
to be ordered separately
to be ordered separately
19045
19042
19043
Wall bracket
Double sided screen with down arrows
Shield suspended with Down arrows
to be ordered separately
to be ordered separately
to be ordered separately
AUTIRIPARA BATTERY
SAFETY SIGNALING (Visibility Distance VD in table)
AUTORIPARA SYSTEM:
Inserting the Autoripara Battery, the device
doubles the power or autonomy, and
intervenes in the case of malfunctioning of
the main battery
19044 Ades Right, Left, Down
supplied
RA01
RA03
AutoRipara Battery System (NiMH 3.6V 1.2Ah)
AutoRipara Battery SYstem (NiMH 3.6V 1.7Ah)
supplied
supplied
23
24
EMERGENCY FIXTURES
The practical flush-mounted box included
allows you to save restricted space and is
essential in elegant contexts that require high
performance and IP65 safety protection.
25
Formula 65 leD extreme
Emergency LED
Designed to withstand extreme temperatures as low as -40 °C such
as those in cold storage units at high altitudes. The emergency Ice
Pack power supply that confers these features is separately supplied
and includes an automatic battery heating system that does not
degrade with extremely low temperatures. The device is designed to
accommodate the feed-through cabling (section 2.5 mm) and is
suitable for use with the M20 commercial cable brackets, both for
smooth and corrugated tubes of 16 and 20 mm diameter.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
800
lumen
10h
ICE PACK
General
FEED THROUGH
CABLE
IP65
10h
12 HOUR
IP RECHARGING
IK07
characteristics
H
HOSPITAL
Equivalent power* 24W
PLUG
850°C
UV
Operation Permanent (SA), Non-permanent (SE)
Rest Mode:with optional control device
(cod. 12101)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, EN 62034
L
Protection level IP65
H
Protection IK07
from knocks
Autonomy 1h, 2h, 3h
H1
B
Environmental 0 ÷ +50 °C
temp. SE non mant.
Environmental 0 ÷ +40 °C
temp. SA mant.
Temp. with ICE PACK -40 ÷ +50 °C (+40°C SA Model)
Installation recessed, wall, ceiling, false ceiling,
suspended wall, suspended ceilin
Body Polycarbonate, white RAL 9003
Optic symmetrical, white
Power**
W
L
24
354
• Size (mm) •
B
H
152
63.4
H1
Visibility Distance (VD)
pictogram
suspended
26
25 m
28 m
* Equivalent power for comparison with florescent tube devices
Shield Transparent polycarbonate
* Equivalent power for comparison with florescent tube devices
AutoRipara accessories
to be ordered separately
Code Order
Description
RA03
AutoRipara Battery System (NiMH 3.6V 1.7Ah)
AUTORIPARA SYSTEM
Inserting the Autoripara Battery, the LED Inverter doubles the power
or autonomy, and intervenes in the case of malfunctioning of the
main battery
26
Accessories
supplied
Code Order Description
19044
N°2 Cable brackets M20
ADES Right Left LOW F65 (only for SA models)
Accessories
to be ordered separately
Code Order
Description
19046
19048
19049
19045
19042
19043
19044
12101
ICE PACK BATTERY
FLUSH-MOUNTED BOX + FRAMES F65 Extreme
FLUSH-MOUNTED BOX + FRAMES F65 Extreme
WALL BRACKET SUSPENDED F65
DOUBLE SIDED SCREEN WITH LEFT/RIGHT ARROWS F65
DOUBLE SIDED SCREEN WITH DOWN ARROWS F65
ADES LEFT RIGHT DOWN F65
Remote control (RM inhibit function)
LOW TEMPERATURE INSTALLATION WITH ICE PACK
Electronic control
Accessory to maintain warm battery temperature
even in working contexts with very low
temperatures (-40°C). Ice Pack is controlled
through an electronic circuit that is able to maintain
a constant battery temperature. The absorption of
the Ice Pack depends on the environmental
temperature.
With Ta=-40°C Pmax= 6w
EMERGENCY FIXTURES
ICE PACK Box
°C
40°
30°
Battery temperature
Battery
(not included in the accessory)
20°
Heating device
Temperature inside
device
10°
0°
THROUGH-WIRING CABLE
-10°
-20°
Environmental temperature
-30°
-40°
Battery temperature alignment
based on environmental temperature
with Ice Pack Accessory
The device is designed to accommodate the feed-through cabling (section
2.5 mm) and is suitable for use with the M20 commercial cable glands,
both for smooth and corrugated tubes of 16 and 20 mm diameter.
LG-AR
Logica
W
Code Order
19269
24 19270
24
Description
Model
Autonomy
Battery
n° LED
Average flux
SE (lm)
Average flux AR
SE (lm)
Average flux
SA l(m)
Abs. max
(W)
F65LED EX 24 IP65 LGAR SE123H S
F65LED EX 24 IP65 LGAR SA123H S
SE
SA
1-2-3h
1-2-3h
NiMH 3.6V 1.7Ah
NiMH 3.6V 1.7Ah
22
22
400/200/140
400/200/140
800/400/270
800/400/270
280
1.5
4.5
Average flux AR
SE (lm)
Average flux
SA l(m)
Abs. max
(W)
800/400/270
800/400/270
280
1.5
5
LGFM-AR
W
0.6
0.6
1/12
1/12
LOGICA FM
Code Order
19275
24 19276
24
Weight
Pack
kg single/multi
Description
Model
Autonomy
Battery
n° LED
Average flux
SE (lm)
F65LED EX 24 LGFMAR SE 123H S
F65LED EX 24 LGFMAR SA 123H S
SE
SA
1-2-3h
1-2-3h
NiMH 3.6V 1.7Ah
NiMH 3.6V 1.7Ah
22
22
400/200/140
400/200/140
Weight
Pack
kg single/multi
0.6
0.6
1/12
1/12
27
accessories
AUTIRIPARA BATTERY
THROUGH-WIRING
AUTORIPARA SYSTEM:
Inserting the Autoripara Battery, the device
doubles the power or autonomy, and
intervenes in the case of malfunctioning of
the main battery
-
THROUGH-WIRING
supplied
2 M20 cable gland (smooth and corrugated tubes ø16 e ø20) supplied
ICE PACK BATTERY
Electronic control
ICE PACK Box
°C
40°
30°
20°
10°
0°
Battery
-10°
(not included in accessory)
Heating device
-20°
-30°
-40°
Accessory to maintain warm battery temperature Battery temperature alignment based on
even in working contexts with very low environmental temperature with Ice Pack
temperatures (-40°C). Ice Pack is controlled Accessory
through an electronic circuit that maintains a
constant battery temperature.
The Ice Pack Battery can only be used on the
battery supplied. It is not intended for use on
additional Autoripara batteries.
19046
28
AutoRipara NiMH Battery System NiMH HT 3.6V 1.7Ah to be ordered separately
HOUSING FOR M20 CABLE GLAND
CABLE GLAND M20
-
RA03
Ice Pack Battery
to be ordered separately
installation accessories
WALL INSTALLATION WITH SPIRIT LEVEL
CEILING INSTALLATION
RECESSED INSTALLATION
RECESSED INSTALLATION ON FALSE CEILING
mounting diameter: 370 x 130 mm
19048
Flush-mounted box + frames F65 Extreme
to be ordered separately
RECESSED INTO FALSE CEILING
19041
19042
19043
False ceiling bracket F65
Double sided screen with left/right arrows
Double sided screen with down arrows
19049
Ceiling bracket F65 Extreme
to be ordered separately
Wall bracket
Double sided screen with left/right arrows
Double sided screen with down arrows
to be ordered separately
to be ordered separately
to be ordered separately
ON WALL
to be ordered separately
to be ordered separately
to be ordered separately
19045
19042
19043
SAFETY SIGNALING (Visibility distance VD in table)
19044 Ades Right, Left, down
supplied
29
Formula 65 LED Extreme, with the Ice Pack
accessory, can be installed in extreme
climatic conditions such as those in cold
storage units.
In this configuration the device will withstand
working temperatures of as low as -40°C
30
31
EMERGENCY FIXTURES
Formula 65 leD capacitor
Emergency LED
Device especially designed for extreme situations, both in terms of
difficult maintenance or extremely low or high environmental
temperatures. The power batteries have been replaced with latest
generation high volume capacitors and are guaranteed for more than
20 years. In addition the Capacitor system completes recharging in
just a few minutes (around 10) compared to the traditional 12/24
hour. This revolutionary feature guarantees a safety level unlike any
other to date. Recharging takes only a few minutes, and so lighting
is always available in emergency situations with repeat blackouts,
making the RM function superfluous.
Safety, the elimination of maintenance costs, very fast recharging
times and working temperatures from -40 e +50°C, this is the
Formula 65 LED Capacitor.
-40°C
General
+50°C 20 years RECHARGING
of life
10 minutes
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
characteristics
IP65
Equivalent power* 8, 11 H
Operation Permanent (SA), Non-permanent (SE)
HOSPITAL
IK07
850°C
UV
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, EN 62034
L
Protection level IP65
Protection IK07
from knocks
H
Accumulato 3V 500F
Capacitor
H1
B
Autonomy 1h, 2h, 3h
Environmental temp. -40 ÷ +50 °C
Installation recessed, wall, ceiling, false-ceiling
Body Polycarbonate, white RAL 9003
Optic symmetrical, white
Shield Transparent polycarbonate
* Equivalent power for comparison with florescent tube devices
Power**
W
L
8
11
354
354
• Size (mm) •
B
H
152
152
63.4
63-4
H1
26
26
Visibility Distance (DV)
pictogram
suspended
25 m
25 m
28 m
28 m
* Equivalent power for comparison with florescent tube devices
Accessories
supplied
Accessories
Code Order
Description
Code Order
Description
19044
N°2 Cable glands M20
ADES LEFT RIGHT DOWN F65 (only for SA models)
19048
19045
19042
19043
19044
FLUSH-MOUNTED BOX + FRAMES F65EX
WALL BRACKET SUSPENDED F65
SHIELD SUSPENDED RIGHT/LEFT F65
SHIELD SUSPENDED DOWN F65
ADES LEFT RIGHT DOWN F65
32
to be ordered separately
Capacitor
power battery
with Super Capacitor
technology
Capacitor, the emergency capacitor power supply
The heart of the system is a latest generation super-capacitor that can
store an exceptionally larger quantity of electrical charge compared to
traditional capacitors. Traditional models have a capacity of mF, whilst
the super capacitors can offer more than 5000 F.
These energy conversion and storage devices have very high specific
power and energy that is greatly superior to conventional capacitors.
In contrast to traditional models, they can be charged or discharged
almost instantaneously thanks to the very high specific power. The
supercapacitors can withstand up to 500,000 recharging and
discharging cycles and if suitably managed guarantee a working life in
standby of up to 20 years.
70.0 Durata dell’emergenza (minuti)
30 anni
anni di vita
60.0
Autonomia
25
50.0
20
40.0
15
30.0
10
20.0
5
10.0
°C
Tempo di carica (minuti)
0.0
-40
-30
-20
-10
0
10
20
30
40
50
Maintenance of performance at low temperature
Formula 65 Capacitor technology permits the maintenance of light
engineering performance and autonomy even in extreme
temperatures. The graphic shows how the life expectancy of the
device is maintained at a very high level at temperatures -40° up to
25° with the accumulators lasting for 20 years.
0
1
2
3
4
5
6
7
8
8
10
Extremely reduced charging time
Charging of the supercapacitors is almost immediate. This feature
ensures a very high level of safety even in the case of repeated
blackouts and makes the Rest Mode superfluous. The recharging
time was 6 minutes for device code 19280 with 1 hour autonomy in
a laboratory test.
AT
AutoTest
W
Code Order
19280
8 19281
11 19282
11 19283
8
Description
Model
Autonomy
Accumulators
n° LED
Average flux
SE (lm)
F65LED 8IP65 AT SC SE1H
F65LED 8IP65 AT SC SA1H
F65LED 11IP65 AT SC SE123H
F65LED 11IP65 AT SC SA123H
SE
SA
SE
SA
1h
1h
1-2-3h
1-2-3h
2x Cap 3V 500F
2x Cap 3V 500F
4x Cap 3V 500F
4x Cap 3V 500F
12
12
12
12
100
100
200/100/70
200/100/70
Average flux Absorp. max* Weight
Pack
SA (lm)
(W)
kg single/multi
250
250
25
25
25
25
0.6
0.6
0.8
0.8
1/12
1/12
1/12
1/12
* Concentrated absorption for the recharging time only (maximum 10 minutes), 0.4W in standby SE models, 3W max in standby SA models
33
accessories
HOUSING FOR M20 CABLE GLAND
CABLE GLAND M20
-
2 M20 cable glands (smooth and corrugated tubes ø16 e ø20)
supplied
WALL INSTALLATION WITH SPIRIT LEVEL
CABLE BRACKET Formula 65
-
CEILING INSTALLATION
1
RECESSED INSTALLATION
RECESSED INSTALLATION ON FALSE CEILING
Recess hole: 370 x 130 mm
19048
34
Flush-mounted box + F65 Extreme frames
to be ordered separately
19049
False-ceiling bracket F65 Extreme
to be ordered separately
EXIT SIGN LUMINAIRE (Visibility distance VD in table)
supplied
RECESSED INTO FALSE CEILING
19041
19042
19043
False-ceiling bracket F65
Shield suspended Right/Left
Shield suspended Down
EMERGENCY FIXTURES
19044 Ades Right, Left, BS
ON WALL
to be ordered separately
to be ordered separately
to be ordered separately
19045
19042
19043
Wall bracket
Shield suspended Right/Left
Shield suspended Down
to be ordered separately
to order separately
to be ordered separately
35
36
EMERGENCY FIXTURES
Extreme installation both in terms of climatic
conditions and difficulty of maintenance. Formula65
Capacitor is the solution that offers maximum safety
in these cases. Recharging time in just a few
minutes, so lighting is always available in emergency
situations with repeated blackouts, in addition the
supercapacitor power system has no limits at low
temperatures and does not exhaust like normal
batteries.
37
38
Ticinque LED Granluce
EMERGENCY FIXTURES
Lighting
The design of safety
for large spaces
When luminous flux makes a
difference Ticinque LED Granluce
comes into play.
Thanks to the extensive surface of
the double reflection parabola that
integrates two highly-effective LED
series, the emission of “useful light”
is at the top of its class offering the
right level of illumination for largescale commercial environments.
The body structure was also
designed for installation in industrial
environments. It can be connected
both with smooth and corrugated
tubes on the four sides of the
device and offers IP65 protection.
39
ticinque leD Granluce
Emergency LED
Device for emergency lighting designed for elevated luminous flux for
installation in large commercial and industrial areas. The white
polycarbonate body includes a cuneiform reflector equipped with two
highly-effective LED series. The highly-transparent polycarbonate
shield has been designed to guarantee IP65 level protection. The
external shell has 4 pre-scored access points, both for the direct
passage of the wiring (IP PLUG Connector) and for connection with
the smooth or corrugated ø16 and ø20 tube (Invisible connector).
10h
General
1250
lumen
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
characteristics
IP65
Power * 24 W
Operation Permanent (SA), Non-permanent (SE)
PLUG
IP
IK07
UV
850°C
12 HOUR H
RECHARGING HOSPITAL
D
Conformity EN 60598-1, EN 60598-2-22,
UNI EN 1838
Protection level IP65
Autonomy 1, 2, 3h
Environmental temp. 0 ÷ +40 °C
H
Installation wall, ceiling
L
B
Body white polycarbonate RAL 9003
Optic Symmetrical, white
Shield Transparent polycarbonate
Power *
W
L
18
549
• Size (mm) •
B
H
147
43
DV
shield
Lamp
25 m
32 LED
*Equivalent power for comparison with florescent tube devices
Accessories
supplied
Code Name
Description
-
no. 3 IP Plug membranes pre-mounted on three exits (High, Right, Left)
no. 1 Invisible connector complete with IP Plug membrane
Accessories
Cod. Name
Description
11582
11583
11584
11585
ADES EXIT TICINQUE LED
ADES LEFT TICINQUE LED
ADES RIGHT TICINQUE LED
ADES DOWN TICINQUE LED
to be ordered separately
CUNEIFORM DOUBLE REFLECTOR WITH LED SIGNAL
40
CEILING INSTALLATION
WALL INSTALLATION
CABLE GLAND
IP CABLE GROMMET
-
EMERGENCY FIXTURES
installation accessories
cable gland PG16/PG20
supplied
EXIT SIGN LUMINAIRE (Visibility distance VD in table)
No. 3 IP cable grommet (pre-mounted)
supplied
-
labels in accessories table
to be ordered separated
TR
Traditional
W
Cod. Order
24
8590
24 8591
Description
Model
Autonomy
Accumulators
n° LED
Average flux
SE (lm)
Average flux
SA (lm)
Abs. max
(W)
Weight
kg
Pack
single/multi
GRANLUCE T5LED IP65 SE2H
GRANLUCE T5LED IP65 SA2H
SE
SA
2h
2h
PB 6V 4Ah
PB 6V 4Ah
32
32
800
800
180
5
5/8
2
2
1/6
1/6
Average flux
SA (lm)
Abs. max
(W)
Weight
kg
Pack
single/multi
400
5
5/15
2
2
1/6
1/6
AT
AutoTest
W
Cod. Order
24
8592
24 8593
Description
Model
Autonomy
Accumulators
n° LED
Average flux
SE (lm)
GRANLUCE T5LED AT IP65 SE123H
GRANLUCE T5LED AT IP65 SA123H
SE
SA
1-2-3h
1-2-3h
PB 6V 4Ah
PB 6V 4Ah
32
32
1250/800/550
1250/800/550
41
42
EMERGENCY FIXTURES
Installation in a shopping center in which the
device must illuminate a particularly
extensive area. In addition, the technological
design is particularly suitable in the
presence of various technical structures for
the display of merchandise.
43
44
UP•LED Lite
LED technology,
top performance, small bulk,
high resistance
more functions
EMERGENCY FIXTURES
UP•LED is a fixture developed in only five
versions but able to satisfy the
requirements of a much wider range
(from 6 to 36W, SE-SA-RM, autonomy 12-3h).
The product concept is centred on a
revolutionary optic system based on 4
precision lenses able to exploit fully all
the power of the LEDs: for the first time
a fixture has been made starting from
the top of the available LEDs.
The main characteristic of the UP•LED
is the very high illumination produced
with very compact dimensions. The
24-36W version reaches 450 Lumen
with a thickness of less than 20 mm.
With a view to multifunctionality,
UP•LED is the first signalling fixture with
the possibility of applying two signs of
different sizes on the same product,
thus obtaining visibility distances (DV) of
20 or 30 m.
This system, totally innovative for the
world of safety signs, is designed both
to illuminate the sign powerfully and
uniformly, but also to direct a beam of
light towards the ground, creating an
illuminated area corresponding to the
emergency exit over which the fixture
is placed. Not least is the mechanical
result: despite the minimal appearance
and the smallest dimensions in the
category, thanks also to the adoption
of O-Ring fixing systems on the whole
housing of the fixture and in the
connecting accessories, UP•LED
ensures lasting Protection degree IP65
and impact resistance IK07
45
UP•leD lite
Emergency lighting fixture characterized by great flexibility of use. Less
than 20mm high, offering are innovative aesthetic impact.
Compactness, high performance, mounting flexibility and high
protection degree make the product ideal for any type of installation.
Available in non-mantained SE and mantained SA versions,
IP42/IP65, 100-2oo lm output flux.
Rest mode input available.The entire range is equipped with all the
accessories to became a signal exit light with visibility from 20 to 30m.
UP•LED LITE is suitable to work with multy voltage power supply:
120Vac and 230Vac.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
General
IP65 IP42 IK07
characteristics
Output 100lm, 200lm
12 HOURS
Power supply 120Vac +/- 10% 60Hz
multy voltage 230Vac +/- 10% 50Hz
RECHARGE
Operation Maintained (SA with Rest Mode)
Non maintained (SE with Rest Mode)
850°C
UV
H
Standard EN 60598-1, EN 60598-2-22, UNI EN
1838, UNI 11222
L
Protection degree IP65 - IP42
Protection IK07
mechanical impacts
B
Autonomy 1h
Working temperature 0°C ÷ +40°C
Mounting wall, ceiling
Housing Polycarbonate, white RAL 9003
L
• Dimensions (mm) •
B
H
DV
213
83
20
20/30
Lens transparent polycarbonate
Accessories
supplied
Accessories
to be ordered separately
Description
Order Code
Description
-
Connection coupling IP65
2 Rear spacers for mounting with connection coupling IP65
2 Caps IP65
cable gland IP65
4310
4311
SCREEN R-L-DOWN UPLED 20M
SCREEN R-L-DOWN UPLED 30M
20
20
42
52,9
Order Code
300
150
83
100
213
200
sign diffuser - visibility distance 20 m
46
sign diffuser - visibility distance 30 m
WALL MOUNTING
SPIRIT LEVEL
MOUNTING IP65 WITH CONNECTION COUPLING
-
4310
supplied
SIGN DIFFUSER VISIBILITY 30M
single sided screen with left/right/down arrows 20m
to be ordered separately
4311
single sided screen with left/right/down arrows 30m
to be ordered separately
BATTERY CONTROL SYSTEM
Red warning LED:
BATTERY
MALFUNCTION
The warning LED follows new protocols linked to compliance with Standard CEI
EN 60598-2-22, which expressly requires the signalling of a battery malfunction
which, in the case of UP•LED, is indicated instantaneously with the appearance
of the colour red on the multicolour warning led (Battery Control System BCS).
UP·LED LITE
Polar Diagram
cd/klm
105
90
75
60
Green warning LED:
FIXTURE
FULLY EFFICIENT
100
150
45
200
30
15
C0-C180
BCS
0
15
30
C90-C270
Battery Control System
Order Code
4340
4341
4342
4343
4344
4345
4346
4347
Description
UP LED LITE 100L IP42 SE RM
UP LED LITE 200L IP42 SE RM
UP LED LITE 100L IP42 SA RM
UP LED LITE 200L IP42 SA RM
UP LED LITE 100L IP65 SE RM
UP LED LITE 200L IP65 SE RM
UP LED LITE 100L IP65 SA RM
UP LED LITE 200L IP65 SA RM
Version Autonomy
SE
SE
SA
SA
SE
SE
SA
SA
1h
1h
1h
1h
1h
1h
1h
1h
Battery
n° LEDs
Flux SE lm
Flux SA lm
Absorption
W
NiCd 3.6V 0.5 Ah
NiCd 3.6V 0.75 Ah
NiCd 3.6V 0.5 Ah
NiCd 3.6V 0.75 Ah
NiCd 3.6V 0.5 Ah
NiCd 3.6V 0.75 Ah
NiCd 3.6V 0.5 Ah
NiCd 3.6V 0.75 Ah
4
4
4
4
4
4
4
4
100
200
100
200
100
200
100
200
100
100
100
100
0.8
1.5
1.5
2.0
0.8
1.5
1.5
2.0
Weight Packaging
kg
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
12
12
12
12
12
12
12
12
47
EMERGENCY FIXTURES
SIGN DIFFUSER VISIBILITY 20M
Connection coupling IP65
48
EMERGENCY FIXTURES
Wall mounting in an architectural design
area. In a tertiary setting the fixture can also
be positioned on the ceiling or with a safety
pictogram (20 or 30m)
49
50
UP•LED Multi
on ceiling with
for holes diam 60 mm
zero visual impact
EMERGENCY FIXTURES
A revolutionary fixture in conceptual
terms considering its spot-like
nature which leaves the optics the
task of directing the beam of light
as required.
There are countless examples of
this concept, especially in terms of
the maximum reduction of the
number of light sources and the
visual dimensions of the fixture: only
9 cm diameter and a thickness of
just a few millimetres.
The fixture is also innovative in its
multifunctional aspect: the shape
and size of the illuminated area can
be radically changed by choosing
from the various lenses supplied: a
single fixture can illuminate 12 m of
escape routes or areas of 65 sq.m
51
UP•leD Multi
Elegant and compact emergency lighting fixture. Made to be
mounted on plasterboard with a hole having a diameter of 60 mm.
Available in two versions: autonomy 1h and 3h. Each version is
equipped with 3 interchangeable lenses: long, large, high.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
General
IP42 IK07
characteristics
12 HOURS
Equivalent power* 24 W
RECHARGE
UV
Power supply 230Vac ± 10% 50Hz
Operation SE, INIBIT (RM)
Standard EN 60598-1, EN 61347-2-7, EN605982-22, EN 61347-2-13, UNI 11222, EN
1838, EN 60598-2-2
Protection degree IP42
A
Autonomy 1h, 3h
Working temperature 0°C ÷ +40°C
Mounting recessed
Control gear Electronic control gear with constant
current
C
Housing Polycarbonate
Lens High-transparency Makrolon PC
B
Heat sink Graphite-charged polyamide
Springs C72 Stainless steel
* Indicative power for comparison with fluorescent tube fixtures
L
G
INVERTER AND BATTERIES
Accessories
Order Code
Description
-
LONG lens with cover
WIDE LENS with cover
HIGH lens with cover
H
supplied
Power*
W
A
B
24
90
40
• Dimensions (mm) •
C
L
60
200
Lamp
G
H
46
43
* Indicative power for comparison with fluorescent tube fixtures
52
1 LED
technical demonstration of light output on the ground
Lungaluce - long lens - mounting 3 m above the ground
SINGLE
MOUNTING
3m
Multiple mounting, fixture centre distance 13 m
covering an escape route of 24.8 m with1 lux in the middle and > 0.5
within 1m
1 lx
1m
11,8 m
3m
MULTIPLE
MOUNTING
13 m
Single mounting
covering an escape route of 11.8 m with1 lux in the middle and >
0.5 within 1m
1 lx
EMERGENCY FIXTURES
1 lx
1m
24,8 m
Largaluce - wide lens - mounting 3 m above the ground
SINGLE
MOUNTING
3m
Multiple mounting, fixture centre distance 8.6 m
illuminates a surface of 16.7 x 16.7 m at 0.5 lux
8,1 m
Illuminated Area
0,5 lx
3m
MULTIPLE
MOUNTING
8,6 m
8,6 m
8,1 m
Single mounting
illuminates a surface of 8.1x8.1 m at 0.5 lux
Illuminated
na ed Area
0,55 lx
16,7 m
16,7 m
Altaluce - high lens - mounting 7 m above the ground
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 11 m
7m
illuminates a surface of 20.5 x 20.5 m at 0.5 lux
11 m
11 m
7m
9,3 m
Illuminated
Illu
uminated Area
u
ea
0,5 lx
MULTIPLE
MOUNTING
9,3 m
Single mounting
illuminates a surface of 9.3 x 9.3 m at 0.5 lux
Illuminated
Illumin
in
naattted
na
ed
d Areaa
0 5 lx
0,5
20,5 m
20,5m
BCS
Battery Control System
W
Order Code
24
4330
4331
24
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Absorption W
UP LED MULTI 60MM SE 1H
UP LED MULTI 60MM SE 3H
SE
SE
1h
3h
NiCd 3.6V 0.75Ah
NiMh 3.6V 1.5Ah
1
1
180
150
1.0
1.5
AT
Weight kg Packaging
0.4
0.4
6
6
AutoTest
W
Order Code
24
4362 UP LED MULTI 60MM AT SE/SA 1-2-3H
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux* SA lm
Absorption W
SE/SA
1h
NiMh 2.7V 1.2Ah
1
235/180/155
155
1/6,5
Weight kg Packaging
0.5
6
53
UP•LED
Fixture with minimum visual impact and
a captivating appearance. In the 24W
equivalent version it is able to emit
450lm, with a photometric solid that
ensures 5 LUX on the ground.
54
UP•LED MULTI
EMERGENCY FIXTURES
In large premises, the UP•LED Multi allows a
considerable reduction of the number of light
sources thanks to its innovative performance,
on both escape and anti-panic routes,
replacing the lens with the most suitable one
supplied.
55
56
Lungalargaluce LED
EMERGENCY FIXTURES
The most beautiful
lamp
recessed
is the one that is not seen
A revolutionary fixture in conceptual
terms which seems to express a
historic thought of minimalist
architecture: “The most beautiful
lamp is the one that is not seen.”
There are countless examples of
the perfect incarnation of this
concept, especially in terms of the
maximum reduction of the number
of light sources and the visual
dimensions of the fixture: only
12 cm diameter and a thickness of
just a few millimetres.
The fixture is also innovative in its
multifunctional aspect: the shape
and size of the illuminated area can
be radically changed by choosing
from the various lenses supplied.
57
lungalargaluce leD
Recessed LED Emergency
High-performance emergency lighting fixture with a kit of special
lenses in highly transparent PMMA, supplied for both the Lungaluce
and the Largaluce version, to obtain different dimensions of the
illuminated surface. Each lens is supplied with an aesthetic mask in
white polycarbonate, with a blocking system for various types of false
ceiling. High-efficiency Led, housing with recessed heat sink in
graphite-charged polyamide.
General
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
characteristics
IP42 AT LG SLG HT
SLGS
IK07 12 HOURS UV
Equivalent power* 24 W
Power supply 230Vac ± 10% 50/60Hz
Operation HT, Permanent (SA)/Non Permanent
(SE)/Public performance (PS) selectable
with DIP switch in the LG and LGFM
versions
RECHARGE
L
A
Standard UNI 11222, EN 60598-1, EN 60598-2-2,
EN 60598-2-22, CEI EN 62471, EN
62034
G
INVERTER AND
BATTERIES
C
Protection degree IP42
(Hole Ø)
H
B
Autonomy 1h, 2h, 3h selectable with DIP switch in
the LG and LGFM versions
Working temperature 0°C ÷ +40°C
Power**
W
A
24
120
Mountings false ceiling, recessed
Housing White polycarbonate RAL 9010
B
• Dimensions (mm) •
C
L
28 80 ÷100
204
G
H
63
46
** Indicative power for comparison with fluorescent tube fixtures
Optics lenses in highly transparent PMMA
Accessories
* Indicative power for comparison with fluorescent tube fixtures
supplied only with items 19331,19332,19333,17466,19330
Order Code
Description
-
LUNGALUCE - long lens with cover
LARGALUCE - wide lens with cover
AT
AutoTest
W*
Order Code
24
24
19331
19334
19335
W*
Order Code
24
19332 L.LARG DW RC LG 24W SE/SA/PS 1/2/3H SE/SA/PS
W*
Order Code
24
19333 L.LARG DW RC LGFM 24W SE/SA/PS 1/2/3H SE/SA/PS
W*
Order Code
24
17466
W*
Order Code
24
19330
W*
Order Code
24
17492
17493
24
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW RC AT 24W SE 1N
L.LARGA DWRC SY AT SE/SA 1/3H
L.LARGA DWRC ASY AT SE/SA 1/3H
SE
SE/SA/PS
SE/SA/PS
1h
1/2/3h
1/2/3h
NiCd 7.2V 0.75Ah
NiMH 7.2V 1.2Ah
NiMH 7.2V 1.2Ah
1
1
1
250
250/190/165
250/190/165
165
165
1
1/6.5
1/6.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
1/6.5
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
2/7.5
Weight kg Packaging
0.8
0.8
0.8
LG
Logica
LGFM
Weight kg Packaging
0.8
6
Logica FM
Description
Version
SLG
Weight kg Packaging
0.8
6
Soccorlogica
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW RC SLG 24W
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW RC HT 24W
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARGA DWRC SY SLGS 24V
L.LARGA DWRC ASY SLGS 24V
-
-
-
1
1
250
250
250
250
5.5
5.5
HT
Weight kg Packaging
0.7
6
Mains voltage power supply
SLGS
Weight kg Packaging
0.7
6
Soccorlogica Sicuro 24V
24
* Equivalent power for comparison with florescent tube devices - ** Minimum flux guaranteed according to EN 60598-2-22
58
6
1/6
1/6
Weight kg Packaging
0.7
0.7
6
6
LENS
Lamps
Cover
LUNGALUCE 3m
1
It covers an escape route of 17.1 m with 1 lux in the middle and >0.5 lux within 1 m of the middle
2
Centre distance 18m between the lamps covering an escape route of 35.1 m with 1 lux in the middle and >0.5 lux within 1 m of the middle
1
Covers a surface of 11.3m x 11.3m with at least 0.5lux with the exception of a 0.5 m perimeter
4
Centre distance 13.2m covering a surface of 24.5m x 24.5m with at least 0.5lux with the exception of a 0.5 m perimeter
LARGALUCE 3m
EMERGENCY FIXTURES
One fixture for several applications
LUNGALUCE - LONG LENS
3m
SINGLE
MOUNTING
LARGALUCE - WIDE LENS
3m
SINGLE
MOUNTING
1 lx
1m
11,3 m
Illuminated
Illum
minated Area
m
0,5 lx
17,1 m
11,3 m
Single mounting
Single mounting
covering an escape route of 17.1m with 1 lux in the middle
and > 0.5 within 1m
3m
MULTIPLE
MOUNTING
18 m
illuminates a surface of 11.3x11.3m at 0.5 lux (128 sq.m)
3m
MULTIPLE
MOUNTING
13,2 m
13,2 m
1 lx
1 lx
1m
IlIlluminatd
d Are
Area 0,5 llx
35,1 m
24,5 m
24,5 m
Multiple mounting, fixture centre distance 18m
Multiple mounting, fixture centre distance 13.2 m
covering an escape route of 35.1m with 1 lux in the middle
and > 0.5 within 1m
illuminates a surface of 24.5x24.5m at 0.5 lux (600 sq.m)
59
60
EMERGENCY FIXTURES
Positioning on an escape route with design
requirements and in the presence of the
public: a single recessed fixture illuminates
a path of up to 18 metres.
61
62
Lungalargaluce LED
EMERGENCY FIXTURES
The most beautiful ceiling
lamp
is the one that is not seen
A revolutionary fixture in conceptual
terms which seems to express a
historic thought of minimalist
architecture: “The most beautiful
lamp is the one that is not seen.”
There are countless examples of
the perfect incarnation of this
concept, especially in terms of the
maximum reduction of the number
of light sources and the visual
dimensions of the fixture: only 14
cm side length and 3 thick.
The fixture is also innovative in its
multifunctional aspect: the shape
and size of the illuminated area can
be radically changed by choosing
from the various lenses supplied.
63
lungalargaluce leD
Ceiling LED Emergency
High-performance emergency lighting fixture with a kit of
special lenses in highly transparent PMMA, supplied for the
Lungaluce, Largaluce and Diffusaluce versions, to obtain
different dimensions of the illuminated surface. Each lens is
supplied with a suitable white polycarbonate housing. Highefficiency Led, housing with recessed heat sink in graphitecharged polyamide.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
General
characteristics
IP42 SLGS AT LG SLG
SLGS HT
IK07 12 HOURS UV
Equivalent power* 24 W
Power supply 230Vac ± 10% 50/60Hz
RECHARGE
Operation HT, Permanent (SA)/Non Permanent
(SE)/Public performance (PS) selectable
with DIP switch in the LG and LGFM
versions
Standard EN 60598-1, EN 60598-2-2, EN
60598-2-22, UNI 11222, CEI EN
62471, EN 62034
Protection degree IP42, IP65 version on request
Autonomy 1h, 2h, 3h selectable with DIP switch in
the LG and LGFM versions
Working temperature 0°C ÷ +40°C
H
B
Mountings ceiling, wall
Housing White polycarbonate RAL 9010
L
Optics lenses in highly transparent PMMA
* Indicative power for comparison with fluorescent tube fixtures
Accessories
supplied only with items 19331,19332,19333,17466,19330
Order Code
Description
-
LUNGALUCE - long lens with cover
LARGALUCE - wide lens with cover
DIFFUSALUCE - diffused lens with cover
Power**
W
L
24
137
• Dimensions (mm) •
B
H
137
32
** Indicative power for comparison with fluorescent tube fixtures
LENS
Lamps
Cover
LUNGALUCE 3m
1
It covers an escape route of 17.1 m with 1 lux in the middle and >0.5 lux within 1 m of the middle
2
Centre distance 18m between the lamps covering an escape route of 35.1 m with1 lux in the middle and >0.5 lux within 1 m of the middle
1
Covers a surface of 11.3m x 11.3m with at least 0.5lux with the exception of a 0.5 m perimeter
4
Centre distance 13.2m covering a surface of 24.5m x 24.5m with at least 0.5lux with the exception of a 0.5 m perimeter
1
Covers a surface of 7x3 m with at least 0.5lux with the exception of a 0.5 m perimeter
2
Centre distance 6.5m covering a surface of 2x3m with at least 0.5lux with the exception of a 0.5 m perimeter
LARGALUCE 3m
DIFFUSALUCE 2.5m
64
Compactness and easy to install
To ensure long duration and high performance of the LED source,
a new technology has been used which simulates heat diffusion
in the fixture: the thermofluidodynamic analysis allows you to
foresee the working temperature of the various components so as
to optimize the heat dissipation system.
In the case of the Lungalargaluce LED Ceiling, the dissipation
organ is the housing of the fixture itself which, to optimize its
efficiency, is made completely of die-cast aluminium.
Lungalargaluce LED is concentrated technology enclosed in a
housing with very small dimensions. The outer casing, in
polycarbonate, can be easily removed by means of two quickrelease locks that do not require a special tool to open them. The
electronics are housed inside, consisting of the LED module,
Inverter and battery pack.
A quick-connecting terminal board is used for the wiring.
AT
AutoTest
W*
Order Code
24
24
19321
19324
19325
W*
Order Code
24
19322 L.LARG DW CL LG 24W SE/SA/PS 1/2/3H SE/SA/PS
W*
Order Code
24
19323 L.LARG DW CL LGFM24W SE/SA/PS 1/2/3H SE/SA/PS
24
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW CL AT 24W SE 1N
L.LARGA DWCL SY AT SE/SA 1/3H
L.LARGA DWCL ASY AT SE/SA 1/3H
SE
SE/SA/PS
SE/SA/PS
1h
1/2/3h
1/2/3h
NiCd 7.2V 0.75Ah
NiMH 7.2V 1.2Ah
NiMH 7.2V 1.2Ah
1
1
1
250
250/190/165
250/190/165
165
165
1
1/6.5
1/6.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
1/6.5
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
2/7.5
Weight kg Packaging
0.6
0.8
0.8
LG
6
1/6
1/6
Logica
LGFM
Weight kg Packaging
0.6
6
Logica FM
Description
Version
SLG
Weight kg Packaging
0.6
6
Soccorlogica
W*
Order Code
24
17464
W*
Order Code
24
19320
W*
Order Code
24
17490
17491
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW CL SLG 24W
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARG DW CL HT 24W
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux** SE lm
Flux SA lm
Absorption W
L.LARGA DWCL SY SLGS 24V
L.LARGA DWCL ASY SLGS 24V
-
-
-
1
1
250
250
250
250
5.5
5.5
HT
Weight kg Packaging
0.5
6
Mains voltage power supply
SLGS
Weight kg Packaging
0.5
6
Soccorlogica Sicuro 24V
24
Weight kg Packaging
0.5
0.5
6
6
* Equivalent power for comparison with florescent tube devices - ** Minimum flux guaranteed according to EN 60598-2-22
65
EMERGENCY FIXTURES
Thermofluidodynamic analysis: calculated heat dissipation
One fixture for several applications
Lungaluce - long lens
Largaluce - wide lens
Diffusaluce - diffused lens
mounted at a height of 3m it covers an escape
route of 17.1m with1 lux in the middle
and > 0.5 within 1m
mounted at a height of 3m it illuminates a surface
of 11.3x11.3m at 0.5 lux (128 sq.m)
mounted on the wall at a height of 2.5m it
illuminates a surface of 7x3 m at 0.5 lux (21 sq.m)
66
technical demonstration of light output on the ground
Lungaluce - long lens - mounting 3 m above the ground
3m
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 18m
covering an escape route of 35.1m with1 lux in the middle and > 0.5
within 1m
1 lx
1m
17,1 m
3m
MULTIPLE
MOUNTING
18 m
covering an escape route of 17.1m with1 lux in the middle and >
0.5 within 1m
1 lx
EMERGENCY FIXTURES
Single mounting
1 lx
1m
35,1 m
Largaluce - wide lens - mounting 3 m above the ground
3m
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 13,2m
illuminates a surface of 24.5x24.5m at 0.5 lux (600 sq.m)
Illuminated
Illum
minated Area
m
11,3 m
0,5 lx
11,3 m
3m
MULTIPLE
MOUNTING
13,2 m
13,2 m
Single mounting
illuminates a surface of 11.3x11.3m at 0.5 lux (128 sq.m)
IlIlluminatd
d Are
Area 0,5 llx
24,5 m
24,5 m
Diffusaluce - diffused lens - mounting 2.5 m above the ground
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 6,5m
illuminates a surface of 12x3m at 0.5 lux (36 sq.m)
2,5 m
3m
Illuminated Area 0,5 lx
7m
MULTIPLE
MOUNTING
6,5 m
2,5 m
Single mounting
illuminates a surface of 7x3 m at 0.5 lux (21 sq.m)
3m
Illuminated Area 0,5 lx
12 m
67
Ceiling installation in a situation of total
darkness with a reduced number of light
sources: anti-panic coverage of an area of
almost 130 sq.m (installation H 3m) with just
one fixture.
68
69
EMERGENCY FIXTURES
70
Granluce LED
EMERGENCY FIXTURES
Design
and
versatility
version 1 LED, 2 LED
for multiple applications
An IP65 fixture that is able to
combine clean lines with a
particularly captivating louvre, “it
does not go unnoticed” and is ideal
for particularly technical or modern
environments; the possibility of
mounting it recessed in the wall
also satisfies the most refined
aesthetic demands. GranluceLED
also has an ecological heart that
pays attention to energy saving: the
battery charging system constantly
reads the level of residual energy
so as to reduce absorption once
the cycle has been completed.
71
Granluce leD 6 -11 W
LED Emergency
Fixture with high technical lighting output. LED light source with
controlled beam lens. Dust-resistant monolithic optics. Polycarbonate
housing, high-transparency diffuser. Large-radius reflector in
metallized polycarbonate with a geometry of complex facets and
sequential reflecting planes. Waterproofing gasket in anti-ageing
expanded EPDM, resistant to atmospheric agents.
High-efficiency electronic circuit in versions SE, SA, with autonomy
of 1 or 3 hours.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
IP65 AT
General
characteristics
UV
850°C
12 HOURS
RECHARGE
Equivalent power* 6, 11 W
Power supply 230Vac ± 10% 50/60Hz
Operation Permanent (SA), Non Permanent (SE)
Standard EN 60598-1, EN 60598-2-2, EN
60598-2-22, UNI EN 1838, UNI 11222
Protection degree IP65
Autonomy 1h, 3h
Working temperature 0°C ÷ +40°C
Mounting wall, ceiling, recessed
Housing Polycarbonate, white RAL 9010
Optics Asymmetrical with complex facets,
metallized
B
* Indicative power for comparison with fluorescent tube fixtures
L
Power**
W
L
B
• Dimensions (mm) •
H
L1
B1
B1
H1
6
213
155
52
240
184
25
11
213
155
52
240
184
25
** Indicative power for comparison with fluorescent tube fixtures
Accessories
L1
supplied
Accessories
Order Code
Description
Order Code
Description
3727
cable gland PG16/PG20 4003/RG
12942
Recess kit 6,11 W
72
H
H1
to be ordered separately
WALL MOUNTING
RECESSED MOUNTING
WALL MOUNTING IP65
12942
RECESS KIT 6, 11W
to be ordered separately
3727
MOUNTING FOR ESCAPE ROUTES ON WALL
EMERGENCY FIXTURES
CEILING MOUNTING
cable gland PG16/PG20 4003/RG
supplied
MOUNTING FOR ESCAPE ROUTES ON CEILING
3m
2,5 m
1m
1m
x (fixture distance)
y (fixture distance)
LIGHT BEAM 6-11 W
6W
y
5m
LIGHT BEAM 6-11 W
6W
x
4m
11 W
5.5 m
11 W
4m
AT
AutoTest
W
03
H
03
03
H
03
Order Code
12950
12951
11 12956
11 12957
6
6
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
GRANLUCE LED IP65 AT 6W SE1NRM
GRANLUCE LED IP65 AT 6W SE3NRM
GRANLUCE LED IP65 AT 11WSE1NRM
GRANLUCE LED IP65 AT 11WSE3NRM
SE
SE
SE
SE
1h
3h
1h
3h
NiCd 4.8V 0.75Ah
NiCd 4.8V 1.7Ah
NiCd 4.8V 0.75Ah
NiCd 4.8V 1.7Ah
1
1
1
58
58
82
82
-
0.2
0.2
0.2
0.2
1
Weight kg Packaging
0.6
0.7
0.6
0.7
12
12
12
12
* Minimum flux guaranteed according to EN 60598-2-22
73
74
EMERGENCY FIXTURES
Recessed wall mounting, close to the
ceiling (H 4 m) thanks to the diffusing beam
directed downwards.
75
Granluce leD 8 -18 -24 W
LED Emergency
Fixture with high technical lighting output. LED light source with
controlled beam lens. Dust-resistant monolithic optics.
Polycarbonate housing, high-transparency diffuser. Large-radius
parabola in metallized polycarbonate with a geometry of complex
facets and sequential reflecting planes. Waterproofing gasket in antiageing expanded EPDM, resistant to atmospheric agents. Highefficiency electronic circuit in versions SE, SA, with autonomy of 1 or
3 hours.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
IP65 AT SLG HT
General
characteristics
850°C
UV
12 HOURS
230V
50Hz
RECHARGE
Equivalent power* 8, 18, 24 W
Power supply 230Vac ± 10% 50/60Hz
Operation Permanent (SA), Non Permanent (SE),
HT
B
Standard EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, EN 62034
Protection degree IP65
L
H
L1
H1
Autonomy 1h, 3h
Working temperature 0°C ÷ +40°C
Mounting wall, ceiling, recessed
B1
Housing Polycarbonate, white RAL 9010
Optics Asymmetrical with complex facets,
metallized
* Indicative power for comparison with fluorescent tube fixtures
Power**
W
L
B
• Dimensions (mm) •
H
L1
B1
8
18
24
355
355
355
180
180
180
58
58
58
388
388
388
213
213
213
H1
Visibility distance (DV)
pictogram
30
30
30
26 m
26 m
26 m
** Indicative power for comparison with fluorescent tube fixtures
Accessories
supplied
Accessories
to be ordered separately
Order Code
Description
Order Code
Description
3727
cable gland PG16/PG20 4003/RG
12943
Recess kit 8,18,24 W
12941 *
CEILING MOUNTING
76
sign labels 8,18,24 W (only version SA)
12941 *
WALL MOUNTING
sign labels 8,18,24 W
RECESSED MOUNTING
RECESS KIT 6, 11W
to be ordered separately
3727
ANTI-PANIC MOUNTING ON WALL
supplied
ANTI-PANIC MOUNTING ON CEILING
LIGHT BEAM 2 LED
Surface
Illumination
cable gland PG16/PG20
LIGHT BEAM 2 LED
20 sq.m
0.5 lux
Surface
Illumination
(on floor)
MOUNTING FOR ESCAPE ROUTES ON WALL
12 sq.m
0.5 lux
(on floor)
MOUNTING FOR ESCAPE ROUTES ON CEILING
3m
2,5 m
1m
1m
x (fixture distance)
y (fixture distance)
LIGHT BEAM 8-18-24 W
8W
18 W
y
5.5 m
6.5 m
LIGHT BEAM 8-18-24 W
8W
18 W
x
4.5 m
5.5 m
24W
7.5 m
24W
7m
AT
H
H
H
H
H
EMERGENCY FIXTURES
12942
WALL MOUNTING IP65
AutoTest
W
Order Code
03
8
03
8
24
12952
12953
12954
12955
12960
12961
12962
12963
12964
12965
12966
12967
W
Order Code
3.6
17332
W
Order Code
3.6
17422
03
8
03
8
03
18
03
18
03
18
03
18
03
24
03
24
03
24
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
GRANLUCE LED IP65 AT 8W SE1NRM
GRANLUCE LED IP65 AT 8W SE3NRM
GRANLUCE LED IP65 AT 8W SA1NRM
GRANLUCE LED IP65 AT 8W SA3NRM
GRANLUCE LED IP65 AT 18WSE1NRM
GRANLUCE LED IP65 AT 18WSE3NRM
GRANLUCE LED IP65 AT 18WSA1NRM
GRANLUCE LED IP65 AT 18WSA3NRM
GRANLUCE LED IP65 AT 24WSE1NRM
GRANLUCE LED IP65 AT 24WSE3NRM
GRANLUCE LED IP65 AT 24WSA1NRM
GRANLUCE LED IP65 AT 24WSA3NRM
SE
SE
SA
SA
SE
SE
SA
SA
SE
SE
SA
SA
1h
3h
1h
3h
1h
3h
1h
3h
1h
3h
1h
3h
NiCd 6V 0.75Ah
NiCd 7.2V 1.7Ah
NiCd 6V 0.75Ah
NiCd 7.2V 1.7Ah
NiCd 6V 0.75Ah
NiCd 7.2V 1.7Ah
NiCd 6V 0.75Ah
NiCd 7.2V 1.7Ah
NiCd 4.8V 1.7Ah
NiCd 7.2V 1.7Ah
NiCd 4.8V 1.7Ah
NiCd 7.2V 1.7Ah
2
2
2
2
2
2
2
2
2
2
2
2
60
60
60
60
116
116
116
116
142
142
142
142
45
45
75
75
75
75
0.2
0.2
0.3
0.3
0.2
0.2
0.3
0.3
0.2
0.2
0.3
0.3
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
GRANLUCE 2LED SLG IP65
SE/SA
1/3h
-
2
-
-
-
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
GRANLUCE 2LED HT IP65
SE/SA
1-3h
-
2
-
-
-
SLG
Weight kg Packaging
0.8
0.9
0.8
0.9
0.8
0.9
0.8
0.9
0.8
0.9
0.8
0.9
6
6
6
6
6
6
6
6
6
6
6
6
Soccorlogica
HT
Weight kg Packaging
0.8
6
Mains voltage power supply
Weight kg Packaging
0.8
6
* Minimum flux guaranteed according to EN 60598-2-22
77
78
EMERGENCY FIXTURES
Recessed mounting on wall in company
reception area Thanks to the recessed
system with a design plate, the
emergency fixture acquires an elegant
and technological appearance.
79
80
LED module
EMERGENCY FIXTURES
Reinventing
with recessed Inverter
emergency lighting
The advantages of high-efficiency
LED technology combined with
precision studies on lens refraction
offered the cue for a new concept
in emergency lighting. Following
these principles, the Inverter with
LED Module was born, a
miniaturized emergency fixture
equipped with a series of
accessories that allow it to be fitted
on normal fixtures for traditional
lighting. The great power of the light
beam is intercepted by a series of
lenses with controlled refraction
that are able to shape the same
number of multifunctional light
beams.
81
leD emergency module
with recessed Inverter
General
High-performance auxiliary device for emergency lighting.
Operation is subordinate to mounting on an existing fixture for
traditional lighting, where the LED module and the respective
inverter with battery pack are positioned. The Kit includes 3
special lenses in high-transparency PMMA, for the Lungaluce,
Altaluce and Largaluce versions, to obtain different dimensions
of the illuminated surface and to allow mounting at heights of
3 to 7 metres. Corresponding to each lens is an aesthetic
mask in white polycarbonate RAL 9010, the LED module is
equipped with a blocking system with an elastic clip for both
T8 and T5 pipes. It is a high-efficiency Led, equipped with a
heat sink in graphite-charged polyamide.
characteristics
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Powers 2 W
Power supply 230Vac ± 10% 50/60Hz
Operation HT, Permanent (SA)/Non Permanent
(SE)/Public performance (PS) selectable
with DIP switch in the versions LG and
LGFM
AT LG SLG
HT SLGS
Standard EN 60598-1, EN 60598-2-2, EN
60598-2-22, UNI EN 1838, UNI 11222,
EN 62034
230V
50Hz
12 HOURS
UV
RECHARGE
Protection degree according to the fixture in which it is
mounted
Autonomy 1h, 2h, 3h selectable with DIP switch in
the LG and LGFM versions
L
B
Working temperature 0°C ÷ +40°C
Mounting on fixtures with T5 and T8 pipes
LED module
H
Housing Graphite-charged polyamide
Optics lenses in highly transparent PMMA
B
H
L
Inverter
L2
L
• Dimensions (mm) •
L1
L2
B
H
18÷58
35
35
33
Inverter
-
114
Battery
-
40
LED module with lens
Power**
W
70
80
32
22
50
4,5
L
L1
L
H
** Indicative power for comparison with fluorescent tube fixtures
B
Accessories
supplied
Order Code
Description
-
3 lenses: LUNGA, LARGA, ALTA with 3 different covers
2 springs for fixing on T8 and T5 pipes
Battery
LENS
Lamps
Cover
LUNGALUCE 3m
1
It covers an escape route of 17.1 m with 1 lux in the middle and >0.5 lux within 1 m of the middle
2
Centre distance 18m between the lamps covering an escape route of 35.1 m with1 lux in the middle and >0.5 lux within 1 m of the middle
1
Covers a surface of 11.3m x 11.3m with at least 0.5lux with the exception of a 0.5 m perimeter
4
Centre distance 13.2m covering a surface of 24.5m x 24.5m with at least 0.5lux with the exception of a 0.5 m perimeter
1
Covers a surface of 12.4m x 12.4m with at least 0.5lux with the exception of a 0.5 m perimeter
4
Centre distance 14.4m covering a surface of 26.8m x 26.8m with at least 0.5lux with the exception of a 0.5 m perimeter
LARGALUCE 3m
ALTALUCE 7m
82
MOUNTING ON A FIXTURE WITH T5 LAMPHOLDERS
Steel clip
supplied
-
Steel clip
supplied
EMERGENCY FIXTURES
-
MOUNTING ON A FIXTURE WITH T8 LAMPHOLDERS
Thermofluidodynamic analysis: calculated heat dissipation
To ensure long duration and high performance of the LED source,
a new technology has been used which simulates heat diffusion
in the fixture: the thermofluidodynamic analysis allows you to
foresee the working temperature of the various components so
as to optimize the heat dissipation system.
AT
AutoTest
W
Order Code
2
19341
W
Order Code
2
19342 MODULE EM LED LG SE/SA/PS 1/2/3H
W
Order Code
2
19343 MODULE EM LED LGFM SE/SA/PS 1/2/3H SE/SA/PS
W
Order Code
2
17467
W
Order Code
2
19340
W
Order Code
2
17465
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
MODULE EM LED AT SE 1N
SE
1h
NiCd 7.2V 0.75Ah
1
250
-
1
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
SE/SA/PS
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
1/6.5
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
1/2/3h
NiMH 7.2V 1.2Ah
1
250/190/165
165
2/7.5
Weight kg Packaging
0.2
LG
H
6
Logica
LGFM
Weight kg Packaging
0.2
6
Logica FM
Description
SLG
Weight kg Packaging
0.2
6
Soccorlogica
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
MODULE EM LED SLG
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
MODULE EM LED HT
-
-
-
1
250
250
5.5
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
MODULE EM LED SLGS 24V
-
-
-
1
250
250
5.5
HT
Weight kg Packaging
0.2
6
Mains voltage power supply
SLGS
Weight kg Packaging
0.2
6
Soccorlogica Sicuro 24V
Weight kg Packaging
0.2
6
* Minimum flux guaranteed according to EN 60598-2-22
83
One fixture for several applications
Dedicated inverter
supplied
3.5 V
700 mA (SE)
350 mA (SA)
battery pack
Lungaluce - long lens
Largaluce - wide lens
Altaluce - high lens
mounted at a height of 3m it covers an escape
route of 17.1m with1 lux in the middle and > 0.5
within 1m
mounted at a height of 3m it illuminates a surface
of 11.3x11.3m at 0.5 lux
mounted at a height of 7m it illuminates a surface
of 12.4x12.4m at 0.5 lux
84
technical demonstration of light output on the ground
Lungaluce - long lens - mounting 3 m above the ground
3m
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 18 m
covers an escape route of 35.1m with 1 lux in the middle
and > 0.5 within 1m
1 lx
1m
17,1 m
3m
MULTIPLE
MOUNTING
18 m
covers an escape route of 17.1m with 1 lux in the middle
and > 0.5 within 1m
1 lx
EMERGENCY FIXTURES
Single mounting
1 lx
1m
35,1 m
Largaluce - wide lens - mounting 3 m above the ground
3m
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 13.2 m
11,3 m
illuminates a surface of 24.5x24.5m at 0.5 lux (600 sq.m)
Illuminated
Illum
minated Area
m
0,5 lx
11,3 m
3m
MULTIPLE
MOUNTING
13,2 m
13,2 m
Single mounting
illuminates a surface of 11.3x11.3m at 0.5 lux (128 sq.m)
IlIlluminatd
d Are
Area 0,5 llx
24,5 m
24,5 m
Altaluce - high lens - mounting 7 m above the ground
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 13.7 m
7m
illuminates a surface of 26.8x26.8m at 0.5 lux (718 sq.m)
13,7 m
12,4 m
Illuminated
Illu
uminated Area
u
ea
0,5 lx
12,4 m
13,7 m
7m
MULTIPLE
MOUNTING
Single mounting
illuminates a surface of 12.4x12.4 m at 0.5 lux
(154 sq.m)
26,8 m
Illuminated
Illumin
ina
naaatte
tedd Areaa
0 5 lx
0,5
26,8 m
85
ecoleD inverter module
High-performance auxiliary device for emergency lighting.
Operation is subordinate to mounting on an existing fixture for
traditional lighting, where the LED module and the respective
inverter with battery pack are positioned. The Kit includes 3
special lenses in high-transparency polycarbonate, for the
Lungaluce, Altaluce and Largaluce versions, to obtain
different dimensions of the illuminated surface and to allow
mounting at heights of 3 or 7 metres. The LED module is
equipped with a blocking system with an elastic clip for both
T8 and T5 lampholders. It is a high-efficiency Led with a
recessed heat sink in graphite-charged polyamide, ensuring a
long duration and great reliability of the fixture.
General
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
characteristics
Powers 1.5 W
TR RM
Power supply 230Vac ± 10% 50/60Hz
12 HOURS
RECHARGE
Version SE, Inhibition (Rest Mode)
230V
50Hz
UV
Standard EN 60598-1, EN 61347-2-7, EN
60598-2-22, , EN 61347-2-13 UNI
11222
Protection degree according to the fixture in which it is
mounted
Autonomy 1h
Working temperature 0°C ÷ +40°C
Mounting on fixtures with T5 and T8 lampholders
L
B
Housing Graphite-charged polyamide
Optics lenses in highly transparent
polycarbonate
LED module
H
B
H
L
Inverter
L2
Power
W
L
• Dimensions (mm) •
L1
L2
B
L
H
LED module
1.5
36
36
28
1 LED
-
114
32
22
-
Battery
-
40
50
4.5
-
80
L1
H
Emergency
conversion kit
70
L
Lamp
B
Battery
Accessories
Order Code
Description
-
3 lenses: LUNGA, LARGA, ALTA with 3 different covers
2 springs for fixing on T8 and T5 lampholders
86
supplied
MOUNTING ON A FIXTURE WITH T5 LAMPHOLDERS
Steel clip
supplied
-
Steel clip
supplied
-
Altaluce
supplied
EMERGENCY FIXTURES
-
MOUNTING ON A FIXTURE WITH T8 LAMPHOLDERS
LENSES SUPPLIED
-
Lungaluce
supplied
-
Largaluce
supplied
Thermofluidodynamic analysis: calculated heat dissipation
To ensure long duration and high performance of the LED source,
a new technology has been used which simulates heat diffusion
in the fixture: the thermofluidodynamic analysis allows you to
foresee the working temperature of the various components so
as to optimize the heat dissipation system.
NOTES
87
One fixture for several applications
Dedicated Inverter
supplied
3V
500 mA
battery pack
Lungaluce - long lens
Largaluce - wide lens
Altaluce - high lens
mounted at a height of 3m it covers an escape
route of 11.8 m with 1 lux in the middle
and > 0.5 within 1m
mounted at a height of 3m it illuminates
a surface of 8.1x8.1 m at 0.5 lux
mounted at a height of 7m it illuminates
a surface of 9.3x9.3m at 0.5 lux
88
technical demonstration of light output on the ground
according to UNI EN 1838
Lungaluce - long lens - mounting 3 m above the ground
3m
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 13 m
covers an escape route of 24.8 m with 1 lux in the middle
and > 0.5 within 1m
1 lx
1m
11,8 m
3m
MULTIPLE
MOUNTING
13 m
Single mounting
covers an escape route of 11.8 m with 1 lux in the middle
and > 0.5 within 1m
1 lx
1 lx
EMERGENCY FIXTURES
1m
24,8 m
Largaluce - wide lenses - mounting 3 m above the ground
SINGLE
MOUNTING
3m
Multiple mounting, fixture centre distance 8.6 m
8,1 m
illuminates a surface of 16.7 x 16.7 m at 0.5 lux
Illuminated Area
0,5 lx
8,1 m
3m
MULTIPLE
MOUNTING
8,6 m
8,6 m
Single mounting
illuminates a surface of 8.1x8.1 m at 0.5 lux
Illuminated
na ed Area
0,55 lx
16,7 m
16,7 m
Altaluce - high lens - mounting 7 m above the ground
SINGLE
MOUNTING
Multiple mounting, fixture centre distance 11 m
7m
illuminates a surface of 20.5 x 20.5 m at 0.5 lux
11 m
9,3 m
Illuminated
Illu
uminated Area
u
ea
0,5 lx
11 m
7m
MULTIPLE
MOUNTING
9,3 m
Single mounting
illuminates a surface of 9.3 x 9.3 m at 0.5 lux
Illuminated
Illumin
in
naattted
na
ed
d Areaa
0,5 lx
20,5 m
20,5m
TR
Traditional
W
Order Code
1.5
19350
19351
1.5
Description
Version
Autonomy
Battery
n° LEDs
Flux* SE lm
Flux SA lm
Absorption W
INVERTER ECOLED SE 1N RM
INVERTER ECOLED SE 3N RM
SE
SE
1h
1h
NiCd 3.6V 0.75Ah
NiCd 3.6V 1.7Ah
1
1
160
160
-
1
1
Weight kg Packaging
0.25
0.25
6
6
* Minimum flux guaranteed according to EN 60598-2-22
89
90
EMERGENCY FIXTURES
Mounting in conventional lighting fixtures in
a transit area with Largaluce lens and in
corridors with a Lungaluce lens in a
centralized SLGS system. The same fixture
in both an anti-panic and an escape route
version.
91
92
Plug&Light LED Inverter
Immediate connection
Emergency Lighting of the highest level,
no re-wiring
integrated
The Plug & Light system marks the new
frontier for inverters for integration of the
emergency unit in lighting devices.
The system is the evolution of the new
Beghelli philosophy that was first presented
with the Smart Drivers, innovative power
suppliers that can be customized according
to specific needs by connecting the various
intelligent modules (domotic radio module,
autodimmer, Dali, Grande Esco Energy
Counter), and in the same spirit,
includes the Plug & Light Inverter.
This inverter is immediately connected
thanks to the rapid insertion connector that
can be directly inserted in the Driver SD
present in all Stella Polare LED devices.
The system was developed to make
installation of the inverter faster without
compromising the features and the
regularity conformity of the Stella Polare LED
device in which it is installed as no wiring is
required. Connection takes only a few
seconds. In addition, the compact cabinet
also includes the battery pack eliminating
the problem of the siting and attachment of
the power source during emergency
functioning.
93
leD Plug&light inverter
Immediate connection inverter
General
Inverter based on Plug&Light patented technology, equipped with a
rapid connector that is compatible with SD (Smart Driver) that comes
as standard in all the devices in the Stella Polare LED range. The
inverter cabinet incorporates the battery pack and features a cable
cover for use removed from the device, such as in the case of Led
Panel or Down light LED, where it is housed in the false ceiling. The
system includes the Battery Control System (BCS) with multi-color
LED signaling system to show battery status, and is compatible with
all LED devices equipped with SELV certified drivers to which it can
be quickly connected using the fast universal terminal board.
The Plug&Light system guarantees the highest level of performance
(for example when installed on BS 100 LED it provides emergency
power of 407 Im), constant output power and complete maintenance
of the conformity features of the Smart Driver device that it is
connected to.
characteristics
Output power 3.2W constant
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Power supply 230Vac 50Hz
Output voltage 20 – 55Vd
24 HOUR
Environmental 0°C ÷ +40°C
temperature
RECHARGING
Rest Mode with optional control device (cod. 2730)
Battery NiCd 7.2V 0.75Ah (1h)
NiMH 7.2V 1.5Ah (3h)
Status LED Bi-color with PC pilot light (BCS)
Body Polycarbonate
Max. output current 160 m
H
Recharging time 24h
B
L
for installation inside lighting devices
shield with selV commercial driver
H
B
L1
Model with terminal board installed (supplied)
for installation removed from the device (leD Panel, Downlight, etc).
shield with sD Driver
Accessories
Cod. Order
—
94
Description
Cable covers
supplied
Power**
W
L
3.2
227
• Size (mm) •
L1
B
317
46
H
Weight
max kg
30
0.3
EXAMPLE OF CALCULATION OF FLOW FOR BS 100 LED (SMART DRIVER) WITH PLUG&LIGHT INVERTER WITH 1hour OF AUTONOMOUS FUNCTIONING (cod 19358)
The Plug&Light Inverter enables you maximize the light engineering
performance of the device on which it is installed. Below is the
calculation method and an example to calculate the Nominal Flow in
an emergency context
F
Flow= P inverter x _____ where:
N
P = Nominal Inverter Power (in the model 1h = 3.2W
Nf = Nominal device flow (for BS100 LED = 7500lm
Np= Nominal power of LED (for BS100 LED = 59W
750
Flow= 3.2 × _____ = 407lm
59
Autonomy 1 hour
Flow 407Im
BATTERY CONTROL SYSTEM
The signaling LED follows the new protocols for conformity to CEI EN 605982-22, that expressly requires signaling of battery malfunctioning that is
instantly communicated via the appearance of a red light on the multi-color
LED signaling system (Battery Control System BCS).
LED red light:
BATTERY
MALFUNCTIONING
LED green light:
FULLY-FUNCTIONING
DEVICE
Immediate connection with SmartDriver
included in all the lighting devices of the Stella
Polare LED range
BCS
Battery Control System
W
3,2
3
Order Code
19358
19359
Description
Model
Autonomy
Battery
Ass max
(W)
INV PLUG&LIGHT LED SE/SA 1H
INV PLUG&LIGHT LED SE/SA 3H
SE/SA
SE/SA
1h
3h
NiCd 7.2V 0.75Ah
NiMH 7.2V 1.5Ah
1
1
Pack
single/multi
1/12
1/12
95
Installation of the Plug&Light Inverter on the BS100 LED
device in a warehouse. This solution does not require
the connection of additional emergency devices and
ensures an excellent level of safety particularly given the
high elevation of the installation: the significant
emergency flow achieved by BS100 LED guarantees
excellent ground-level illumination in blackouts even at
heights of 10 meters.
96
97
98
Conversion Kit for LED
the emergency
IP40-IP65
in lighting
EMERGENCY FIXTURES
The new line of Inverters for LED
source fixtures is characterised by
high performance and great
flexibility.
Available in IP40 and IP65 versions,
it is a perfect match for lighting
technologies of the latest
generation, to produce an
unprecedented technological
partnership. Both for complex
systems and for elevated
installation heights, the possibility of
transforming high-efficiency LED
fixtures into emergency lighting can
become the only solution possible
with a suitably guaranteed result.
Moreover, the availability of
centralized versions (SLGS)
conforms the technological
vocation of this range devices,
created to provide a successful
solution to all demands for safety
lighting.
99
conversion kit for leD
General
Electronic control gear for emergency lighting to light the LED
modules. Autonomy independent of the lamp and selectable, 1 hour,
2 hours and 3 hours.
The control of the output current with PWM modulation at a constant
peak current allows the best control of the LED module, avoiding
effects of distortion of the light flux and of the LED colour temperature.
Maximum versatility for a LED conversion kit. Self-adapting output
voltage with automatic load recognition. Output power independent of
the connected LED module, and from today, thanks to the new
Autoripara Battery, the safety and power are doubled.
The LED conversion kit is able to recognize the presence of the
second battery and to double the power output from 6w to 12w.
The recharging system guarantees 1h of autonomy after 12h of
recharging in the 2h and 3h configurations.
The disconnection by relay of the power supply arriving from the driver
and of the LED circuit make the Beghelli LED conversion kit a
universal product, compatible with all drivers.
If not reached by the BUS, the LG version automatically performs selfdiagnosis (AutoTest).
characteristics
Working Temperature 0 + 50°C (Battery)
-20 + 50°C (Inverter)
Max temperature
on the Box 70°C
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Output voltage 3÷55V
Peak output current 500mA
AT LG LGFM IP40
Recharging time 24h
230V
50Hz
24RICARICA
ORE
Max output power 6W - 12W (with Autoripara battery)
Recharging current 85mA
H
Battery NiMh 7.2V 1.7Ah (high temperature)
L
Rest Mode with optional control device
(Cod. 12101)
Status Led Bi-color
Auto testart Compatible with test button in the AT
configuration
B
L
Ø
Housing Polycarbonate
conversion kit dimensions (mm)
L
B
H
Control systems AT
LG
LGFM
Available in the DALI version
AutoRipara Accessories
232
30
26
Battery dimensions (mm)
L
Ø
H
132
17,5
35
to be ordered separately
Order Code
Description
Battery
RA02
BATT SYST AUTORIPARA conversion kit
NiMh 7.2V 1.7Ah
AUTORIPARA SYSTEM
When the Autoripara battery is inserted, the LED conversion kit
doubles the power or the autonomy, as well as intervening in the
event of a malfunction of the main battery
AT-LG
Logica
W
Order Code
Description
Control
Version
Autonomy
Battery
Max abs.
Packaging
2÷6
19355
CONVERSION KIT LED AT/LG 6w 55V 123h
AT/LG
SA
1-2-3H
NiMh 7.2V 1.7Ah
2
1
AT-LGFM
100
Logica FM
W
Order Code
Description
Control
Version
Autonomy
Battery
Max abs.
Packaging
2÷6
19356
CONVERSION KIT LED LGFM 6w 55V 123h
LGFM
SA
1-2-3H
NiMh 7.2V 1.7Ah
2
1
General
Electronic control gear for emergency lighting to light the LED
modules. Autonomy independent of the lamp and selectable, 1 hour,
2 hours and 3 hours.
The control of the output current with PWM modulation at a constant
peak current allows the best control of the LED module, avoiding
effects of distortion of the light flux and of the LED colour temperature.
Maximum versatility for a LED conversion kit. Self-adapting output
voltage with automatic load recognition. Output power independent of
the connected LED module, and from today, thanks to the new
Autoripara Battery, the safety and power are doubled.
The LED conversion kit is able to recognize the presence of the
second battery and to double the power output from 6w to 12w.
The recharging system guarantees 1h of autonomy after 12h of
recharging in the 2h and 3h configurations.
The disconnection by relay of the power supply arriving from the driver
and of the LED circuit make the Beghelli LED CONVERSION KIT a
universal product, compatible with all drivers.
If not reached by the BUS, the LG version automatically performs selfdiagnosis (AutoTest).
characteristics
Working Temperature 0 + 50°C (Battery)
-20 + 50°C (Inverter)
Max temperature
on the Box 70°C
Output voltage 3÷55V
Peak output current 500mA
Recharging time 24h
IP65 AT LG LGFM
Max output power 6W - 12W (with Autoripara battery)
24 HOURS
RECHARGE
230V
50Hz
Recharging current 85mA
Battery NiMh 7.2V 1.7Ah (high temperature)
Rest Mode with optional control device
(Cod. 12101)
Status Led Bi-color
Auto testart Compatible with test button in the
AT configuration
H
L
Housing Extruded aluminium
Control systems AT
Inverter dimensions (mm)
L
B
H
LG
LGFM
Available in the DALI version
AutoRipara Accessories
B
258
76
41
to be ordered separately
Order Code
Description
Battery
RA02
BATT SYST AUTORIPARA INVERTER
NiMh 7.2V 1.7Ah
AUTORIPARA SYSTEM
When the Autoripara battery is inserted, the LED conversion kit
doubles the power or the autonomy, as well as intervening in the
event of a malfunction of the main battery
AT-LG
Logica
W
Order Code
Description
Control
Version
Autonomy
Battery
Max abs.
Packaging
2÷6
19364
CONVERSION KIT LED AT/LG 6w 55V 123h
AT/LG
SA
1-2-3H
NiMh 7.2V 1.7Ah
2
1
AT-LGFM
Logica FM
W
Order Code
Description
Control
Version
Autonomy
Battery
Max abs.
Packaging
2÷6
19365
CONVERSION KIT LED LGFM 6w 55V 123h
LGFM
SA
1-2-3H
NiMh 7.2V 1.7Ah
2
1
101
EMERGENCY FIXTURES
conversion kit for leD iP65
Extreme
industrial
installation
with
emergency lighting inserted in the light
fixture: the emergency conversion kit only
powers part of the light source, it is not
necessary to apply further fixtures for antipanic emergency lighting.
102
103
EMERGENCY FIXTURES
104
Indica LED 20
Designunprecedented
and sturdiness
for
uniformity
multiple applications
SIGN FIXTURES
The whole line of new products for
safety signs is characterised by
functionality and aesthetics
combined in a single organic form
of aluminium and glass. Visually
strict and minimal, they are really
high-tech fixtures especially for
their compact dimensions which
nevertheless do not affect the
generous brightness of the
diffusers in any environmental light
situation. The final effect is slender
and light, only the extreme
uniformity of the sign is amazing,
almost defying the laws of technical
lighting known up till now.
105
indica leD 20m
LED signs
General
Indica LED is the design solution for sign lighting requirements, with a
high technological content for all types of applications. A back light
system is used and, thanks to a patented optical system, it
guarantees maximum uniformity of sign illumination with excellent
luminosity. The fixture is also particularly versatile because it has a
universal bracket that can be fitted either on the long side, for
mounting on the ceiling, or on the long side for suspended
applications on the wall. A single-sided version is also available for
above-door installations. All Indica LED products have silk-screen
printed opaline polycarbonate diffusers for easier installation and to
guarantee a very high sign illuminance uniformity (over 500cd/sq.m)
on the white part.
characteristics
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Powers 1-2.1 W
Power supply 230Vac ± 10% 50/60Hz
Operation HT, Permanent (SA)/Public performance
(PS) selectable with DIP switch in
versions LG and LGFM
IP40
IP41
Standard EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, DIN 4844-1, EN 62034
AT LG SLG HT
230V
50Hz
SLGS
UV
850°C
Protection degree IP40 single-sided version, IP41
suspended version
Autonomy 1h, 2h, 3h selectable with DIP switch in
the LG and LGFM versions
Working temperature 0°C ÷ +40°C
Mounting wall, false ceiling, ceiling with rods,
suspended on wall, suspended on ceiling,
Housing Aluminium frame and bracket in
polycarbonate RAL 7035
Optics high-efficiency back light system
Wall double-sided version
Ceiling double-sided version
Recessed single-sided version
H
Wall single-sided version
L
B
B
L
H
B
H
B
L
L
H
DV
L
B
H
DV
L
B
H
DV
L
B
H
DV
L
B
H
20
266
252
36
20
235
166
36
20
235
135
15
20
235
135
38
Accessories
supplied
Accessories
Order Code
Description
Order Code
Description
-
DIFFUSER R/L/DOWN
19380
19381
19382
19383
19384
TIGES 250MM INDICA DF
TIGES 500MM INDICA DF
TIGES 1000MM INDICA DF
WIRE SUSPENSION 2MT INDICA DF
FALSE CEILING RECESSED BRACKET 20M
106
to be ordered separately
MOUNTING ON WALL
MOUNTING ON CEILING
SUSPENDED CANTILEVERED MOUNTING
CANTILEVERED MOUNTING ON CEILING WITH TIGES
19383 Wire suspension max 100
19380
19381
19382
to be ordered separately
RODS 250MM INDICA DF
RODS 500MM INDICA DF
RODS 1000MM INDICA DF
to be ordered separately
Recess hole dimensions: 297x43 mm
19384 Recess bracket for false ceiling 20 m
to be ordered separately
Double-sided version
AT
IP41
AutoTest
W
Order Code
2.1
19303
W
Order Code
2.1
19305
W
Order Code
2.1
19307 INDICA LED DF20M LGFM SA/PS 1/2/3H
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF20M AT SA 1/H
SA
1/h
NiMh 7.2V 0.6Ah
32
3.5
0,52
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF20M LG SA/PS 1/2/3H
SA/PS
1/2/3h
NiMh 7.2V 0.6Ah
32
3.5
0.52
6
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
SA/PS
1/2/3h
NiMh 7.2V 0.6Ah
32
3.5
0.52
6
LG
H
Logica
LGFM
H
Logica FM
Description
SLG
Soccorlogica
W
Order Code
2.1
17461
W
Order Code
2.1
19301
W
Order Code
2.1
17495
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF20M SLG
-
-
-
32
3
0.52
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF20M HT
-
-
-
32
3
0.52
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF20M SLGS 24V
-
-
-
32
3
0.52
6
HT
Mains voltage power supply
SLGS
Soccorlogica Sicuro 24V
107
SIGN FIXTURES
RECESSED MOUNTING INTO FALSE CEILING
WALL MOUNTING
RECESSED WALL MOUNTING ON BOX 506
-
adapter for boxes 506
supplied
Single-side version
AT
IP40
AutoTest
W
Order Code
1
19313
W
Order Code
1
19315
W
Order Code
1
19317 INDICA LED SF20M LGFM SAPS 1/2/3H
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF20M AT SA 1N
SA
1h
NiCd 7.2V 0.75Ah
16
2.6
0.65
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF20M LG SAPS 1/2/3H
SA/PS
1/2/3h
NiMH 7.2V 1.2Ah
16
2.6
0.65
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
SA/PS
1/2/3h
NiMH 7.2V 1.2Ah
16
2.6
0.65
6
LG
Logica
LGFM
Logica FM
SLG
Soccorlogica
W
Order Code
1
17463
W
Order Code
1
19311
W
Order Code
1
17497
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF20M SLG
-
-
-
16
2
0.65
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF20M HT
-
-
-
16
2
0.65
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF20M SLGS 24V
-
-
-
16
2
0.65
6
HT
Mains voltage power supply
SLGS
108
Soccorlogica Sicuro 24V
QUICK CONNECTION BRACKET
FOR MAXIMUM MOUNTING VERSATILITY
The frame, in extruded aluminium, has been designed as a
fixing track.
This particular conformation, as well as making the Indica LED
more sturdy and rigid, allows the fixing bracket to be applied on
all sides of the fixture.
The polycarbonate diffusers can be removed without the aid of
special tools.
Simplicity, versatility and sturdiness are the basic principles of the
Indica LED project. All of this is achieved with unprecedented
luminosity of the sign.
SIGN FIXTURES
Bracket position for mounting on the ceiling
Bracket position for suspended
mounting on the left
Bracket position for suspended mounting on
the right
109
Ceiling mounting in a shopping centre
where the design is important, but
versatility is even more important: the same
fixture in suspended wall, single-side and
suspended ceiling version.
110
111
SIGN FIXTURES
112
Indica LED 30
Design and
sturdiness
for
visible from 30 metres
multiple applications
SIGN FIXTURES
The whole line of new products for
safety signs is characterised by
functionality and aesthetics
combined in a single organic form
of aluminium and glass. Visually
strict and minimal, they are really
high-tech fixtures especially for
their compact dimensions which
nevertheless do not affect the
generous brightness of the
diffusers in any environmental light
situation. The final effect is slender
and light, only the extreme
uniformity of the sign is amazing,
almost defying the laws of technical
lighting known up till now.
113
indica leD 30m
LED signs
General
Indica LED is the design solution for sign lighting requirements, with a
high technological content for all types of applications. A back light
system is used and, thanks to a patented optical system, it
guarantees maximum uniformity of sign illumination with excellent
luminosity. The fixture is also particularly versatile because it has a
universal bracket that can be fitted either on the long side, for
mounting on the ceiling, or on the long side for suspended
applications on the wall. A single-sided version is also available for
above-door installations. All Indica LED products have silk-screen
printed opaline polycarbonate diffusers for easier installation and to
guarantee a very high sign illuminance uniformity (over 500cd/sq.m)
on the white part.
characteristics
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
Powers 1.6-3.2 W
Power supply 230Vac ± 10% 50/60Hz
Operation HT, Permanent (SA)/Public performance
(PS) selectable with DIP switch in
versions LG and LGFM
IP40
IP41
Standard EN 60598-1, EN 60598-2-2, EN
60598-2-22, UNI EN 1838, UNI 11222,
DIN 4844-1, EN 62034
AT LG SLG HT SLGS
230V
50Hz
UV
850°C
Protection degree IP40 single-sided version, IP41
suspended version
Autonomy 1h, 2h, 3h selectable with DIP switch in
the LG and LGFM versions
0°C ÷ +40°C
Working temperature
Mounting wall, false ceiling, ceiling with rods,
suspended on wall, suspended on
ceiling,
Housing Aluminium frame and polycarbonate
bracket RAL 7035
Optics high-efficiency back light system
Wall double-sided version
Ceiling double-sided version
Recessed single-sided version
H
Wall single-sided version
L
B
B
L
H
B
H
B
L
L
H
DV
L
B
H
DV
L
B
H
DV
L
B
H
DV
L
B
H
30
366
252
36
30
335
216
36
30
335
185
15
30
335
185
38
Accessories
supplied
Accessories
to be ordered separately
Order Code
Description
Order Code
Description
-
DIFFUSER R/L/DOWN
19380
19381
19382
19383
19386
RODS 250MM INDICA DF
RODS 500MM INDICA DF
RODS 1000MM INDICA DF
WIRE SUSPENSION 2MT INDICA DF
RECESSED BRACKET FOR FALSE CEILING 30M
114
SUSPENDED MOUNTING ON WALL
SUSPENDED MOUNTING ON CEILING
SUSPENDED SUSPENDED MOUNTING
SUSPENDED MOUNTING ON CEILING WITH RODS
19380
19381
19382
to be ordered separately
RECESSED SUSPENDED MOUNTING ON FALSE CEILING
RODS 250MM INDICA DF
RODS 500MM INDICA DF
RODS 1000MM INDICA DF
to be ordered separately
Recess hole dimensions: 367x43 mm
19384 False ceiling recess bracket 30 m
to be ordered separately
Double-sided version
AT
AutoTest
W
Order Code
3.2
19302
W
Order Code
3.2
19304
W
Order Code
3.2
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF30M AT SA 1H
SA
1h
NiMh 7.2V 0.6Ah
48
4.2
0.8
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED DF30M LG SA/PS 1/2/3H
SA/PS
1/2/3h
NiMH 7.2V 0.6Ah
48
4.2
0.8
6
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
19306 INDICA LED DF30M LGFM SA/PS 1/2/3H
SA/PS
1/2/3h
NiMH 7.2V 0.6Ah
48
4.2
0.8
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
3.2
17460
INDICA LED DF30M SLG
-
-
-
48
3.7
0.8
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
3.2
19300
INDICA LED DF30M HT
-
-
-
48
3.7
0.8
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
3.2
17494
INDICA LED DF30M SLGS 24V
-
-
-
48
3.7
0.8
6
LG
H
Logica
LGFM
H
IP41
Logica FM
Description
SLG
Soccorlogica
HT
Mains voltage power supply
SLGS
Soccorlogica Sicuro 24V
115
SIGN FIXTURES
19383 Wire suspension max 100
Single-sided version
AT
IP40
AutoTest
W
Order Code
1.6
19312
W
Order Code
1.6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
INDICA LED SF30M AT SA 1N
SA
1h
NiCd 7.2V 0.75Ah
24
3
1.1
6
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
19314 INDICA LED SF30M LG SAPS 1/2/3H
SA/PS
1/2/3h
NiMH 7.2V 1.2Ah
24
3
1.1
6
W
Order Code
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
1.6
19316 INDICA LED SF30M LGFM SAPS 1/2/3H
SA/PS
1/2/3h
NiMH 7.2V 1.2Ah
24
3
1.1
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
1.6
17462
INDICA LED SF30M SLG
-
-
-
24
2.5
1.1
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
1.6
19310
INDICA LED SF30M HT
-
-
-
24
2.5
1.1
6
W
Order Code
Description
Version
Autonomy
Battery
n° LEDs
Absorption W
Weight kg
Packaging
1.6
17496
INDICA LED SF30M SLGS 24V
-
-
-
24
2.5
1.1
6
LG
Logica
LGFM
Logica FM
Description
SLG
Soccorlogica
HT
Mains voltage power supply
SLGS
Soccorlogica Sicuro 24V
WALL MOUNTING
RECESSED WALL MOUNTING ON BOX 506
-
116
adapter for boxes 506
supplied
QUICK CONNECTION BRACKET
FOR MAXIMUM MOUNTING VERSATILITY
The frame, in extruded aluminium, has been designed as a
fixing track..
This particular conformation, as well as making the Indica LED
more sturdy and rigid, allows the fixing bracket to be applied on
all sides of the fixture.
The polycarbonate diffusers can be removed without the aid of
special tools.
Simplicity, versatility and sturdiness are the basic principles of the
Indica LED project. All of this is achieved with unprecedented
luminosity of the sign.
SIGN FIXTURES
Bracket position for mounting on the ceiling
Bracket position for suspended mounting on
the left
Bracket position for suspended mounting on
the right
117
Suspended mounting in a conference
centre where the spaces require high
visibility distances (30m)
118
119
SIGN FIXTURES
120
UP•LED Exit Lite
the key word is
wall, ceiling or suspended
versatility
without additional accessories
SIGN FIXTURES
A range of new exit sign luminaires
characterized by functionality and
versatility with extremely reduced
size and a clean and elegant
design thanks to the innovative
universal concealed fixing system.
The common feature is functional
simplicity with respect to both
installation and reliability. Includes a
fast concealed clamp which can
be installed laterally, at the back or
on the upper section, to meet all
the requirements of a exit sign
device in a single product. The
luminosity and the uniformity of the
pictogram are at the top of the
class.
121
UP•leD exit lite
LED device for emergency signaling. Simple and linear as well as
innovative thanks to its ease of installation.
Available in versions with 20m, 30m and 60m visibility.
The polycarbonate permits wall, ceiling and suspended installation
with the use of the same universal clamp supplied.
The serigraphed shield guarantees the greatest uniformity of signage
illumination at high luminosity signal (more than 500cd/m2 on white
wall). UP·LED Exit Lite is suitable to work with power supply multy
voltage: 120Vac and 230Vac.
Photometric diagrams and Luce Utile page 149, Symbols on cover,
Spare batteries page 160
General
characteristics
VISIBILITY
up to 60m
IP40 H
HOSPITAL
Power 2W, 3W, 6W
850°C
UV
Power supply 120/230Vac ± 10% 50/60Hz
Operation SA INIBIT (RM)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, DIN 4844-1
Protection level
H
L
IP40
Autonomy 1h
Environmental temp. 0 ÷ +40 °C
Installation wall, false ceiling, ceiling with stems
and cables suspended wall, suspended
ceiling
B
Power supply Electronic
constant current
Body Polycarbonate, white RAL 9003
Accessories
supplied
Power
W
Visibility distance (VD)
m
L
• Size (mm) •
B
H
2
3
6
20
30
60
229
329
629
155
205
355
30
30
30
Accessories
to be ordered separately
Cod. Name
Description
Cod. Name
Description
-
SHIELDS RIGHT, LEFT, DOWN
UNIVERSAL CLAMP
4312
4313
4315
4316
4317
14771
ACCESSORY CEILING RECESS 20m
ACCESSORY CEILING RECESS 30m
ACCESSORY SUSPENSION WITH STEMS L250
ACCESSORY SUSPENSION WITH STEMS L500
ACCESSORY SUSPENSION WITH STEMS L1000
ACCESSORY SUSPENSION WITH CABLES
TR-BCS
Traditional with Battery Control System
W
Cod. Order
2
4350
4351
4352
3
NOVITÀ
122
6
Description
Model
Autonomy
Battery
n° LED
Abs. max (W)
Weight kg
Pack single/multi
UP LED LITE EXIT 20M SA RM 1H
UP LED LITE EXIT 30M SA RM 1H
UP LED LITE EXIT 60M SA RM 1H
SA
SA
SA
1/2/3h
1/2/3h
1/2/3h
NiCd 3.6V 0.75Ah
NiMH 3.6V 1.2Ah
2x NiMH 3.6V 1.2Ah
24
36
72
2.5
3.5
7.0
0.3
0.5
1.0
1/6
1/6
1/6
The right visibility for every space
The range of signage devices that adapts to spaces of
every size, from the warehouse to the office and from
industrial to designer structures.
Visibility distance
VD 20 meters
Visibility distance
VD 60 meters
Visibility distance
VD 30 meters
Universal concealed fixing system:
The universal concealed bracket can be installed laterally, at the
back or on the upper section, to meet all the requirements of a
exit sign device in a single product.
BCS - BATTERY CONTROL SYSTEM
Universal bracket (vers. 20/30m)
2x universal brackets (vers. 60m)
LED red light:
BATTERY MALFUNCTIONING
CEILING INSTALLATION
WALL INSTALLATION
-
SIGN FIXTURES
LED green light:
FULLY-FUNCTIONING DEVICE
The signaling LED follows the new protocols for conformity to CEI EN 60598-2-22,
that expressly requires signaling of battery malfunctioning that in the case of
UP•LED is instantly communicated via the appearance of a red light on the multicolor LED signaling system (Battery Control System BCS).
supplie
supplied
-
Universal bracket (vers. 20/30m)
2x universal brackets (vers. 60m)
supplied
supplied
SUSPENDED INSTALLATION
-
Universal bracket
supplied
123
UP•LED EXIT LITE
Suspended installation for a sober and
elegant effect. The practical bracket
permits wall or ceiling positioning.
124
UP•LED MULTI
SIGN FIXTURES
The device is particularly suitable for
complex architectural spaces in which it
remains invisible whilst offering perfect
lighting
125
126
Technical
annex
Design
129
Control systems
AT - AutoTest
100
AR - AutoTest Ripara
100
LGFM - Logica FM
101
LG - Logica
102
SLG - Soccorlogica
103
SLGS - Soccorlogica
Sicuro 24V
109
Examples of mounting
Local control AT
114
Centralized control
LG-LGFM-SLG-SLGS
116
The Academy for
professionals
118
Photometric diagrams
and Luce Utile
119
127
LOGICA management software VISUAL
Software for the management of one or more centralized
emergency lighting systems of the Series LOGICA, LOGICA FM
and SoccorLogica. It is possible to import the plans in standard
formats and to complete them with the positioning of the various
lighting and emergency devices. The video interface allows direct
Checking for faults and system management
action on the devices and display of their status. It allows all the
operations contemplated by the control unit to be performed in
remote mode: a report on the system status can be obtained
automatically. The reports can be archived, creating a historic
trace of the status of the various systems.
Plan of the system
PROGEM calculation software
This is the software created by the Beghelli Research Centre for
lighting design. It contains all the technical data sheets of Beghelli
products for both lighting and emergency lighting. It allows the
processing of CAD Data from other architectural programs and
exporting of the results with the greatest simplicity. It is an effective
tool allowing the creation of:
• Professional and efficient projects with maximum simplicity
System design
128
• Calculation of emergency lighting in compliance with standard
UNI-EN 1838.
• Calculation of bill of quantities with dimensions
• Display of the lighting result with environment rendering
• Definition of the environment, the escape routes and the anti-panic
areas
Simulation of the final result
Design
DIALUX calculation software
One of the most widespread lighting softwares at international
level for professional lighting design. It can process CAD Data from
other architectural programs and export the results with the
greatest simplicity. It is an effective tool allowing the creation of:
• Professional and efficient projects with maximum simplicity
• Realistic rendering and films
•
•
•
•
Energy assessment
Luminous lighting and emergency lighting scenes
Technical data sheets of the products in the catalogue
Definition of the environment, the escape routes and the anti-panic
areas
• Calculation of emergency lighting in compliance with standard
UNI-EN 1838.
Choosing the fixture
Choosing the fixture
System design
System design
Simulation of the final result
Simulation of the final result
129
AT - AutoTest: the recessed control system
HIGH EFFICIENCY LED
POWER SUPPLY
BATTERY
SWITCH-OVER
MICROPROCESSOR
SIMPLIFIES THE PROCEDURES LISTED BY STANDARD UNI 11222
This system guarantees the control operations that must be
carried out by the Head of the prevention and protection service
according to Decree 81/08 of the Consolidation act on safety on
the workplace.
The autonomy test includes checking of all the lamp functions in a
space of time equal to the autonomy required by the individual
standards and it is carried out every 26 weeks; there is also an
operation test every 28 days, concerning the lamp, battery and
circuit. The result of the tests is shown by the multicolour LED on
the fixtures. This always guarantees perfect control of operation
and allows an economic saving on the costs of personnel who
otherwise would be assigned to maintenance.
1 MULTICOLOR LED
ELECTRONICALLY CONTROLLED RECHARGING TO SAVE ENERGY AND DOUBLE THE BATTERY LIFE
The waste of energy, caused by the continuous recharging of
emergency fixtures, is often neglected. Beghelli, always attentive to
environmental issues, has created a recharging system which, as
soon as the battery has completed the cycle (12 hours), automatically
passes to the next stage to maintain the charge, limiting lamp
absorption to less than one Watt.
This SYSTEM, which appreciably reduces the waste of energy,
limits thermal build-up and consequent stress on the battery
which, consequently, will have an increase of its working life that
is double the life obtained with conventional circuits.
AR - AutoTest Ripara:
from AT to AR with an extra battery
The self-powered emergency lighting fixtures in the AutoRipara
series are the fruit of sophisticated electronic technology, which
also includes a microprocessor able to integrate a high number of
functions. As well as switching on automatically in the absence of
mains power, the fixtures perform periodic self-control tests
regarding both operation and autonomy, as required by Standard
UNI11222.
To perform the tests the AutoRipara system simulates the
absence of mains power and checks that the fixtures are working
correctly. The operation test checks all the lamp functions in the
space of 1 minute and is held monthly. The autonomy test
includes checking of all the lamp functions in a space of time
equal to the autonomy required by the individual standards and it
is carried out every 26 weeks. The result of the tests is shown by
the multicolour LED on the fixtures. This always guarantees
perfect control of operation and allows an economic saving on
the costs of personnel who otherwise would be assigned to
maintenance. AutoRipara fixtures can be installed in existing
emergency lighting systems without requiring the laying of further
wiring.
130
POWER SUPPLY
CHARGING CIRCUIT
BATTERY 1
BATTERY 2
LED MATRIX
SWITCH-ON
UNIT 1
SWITCH-ON
UNIT 2
MULTICOLOUR
LED
MICROPROCESSOR
AUTORIPARA EXTRA BATTERY
the addition of the extra battery set automatically doubles the flux,
keeping the autonomy unchanged. acting on the electronic circuit,
the greater light flux can be reduced, bringing the emergency
duration from 1 hour to 2 or 3 hours.
Control systems
LGFM - Logica FM:
the centralized system by radio
SISTEMA LOGICA CT BY RADIO
(up to 992 fixtures)
The LOGIC FM Control unit manages and controls emergency
fixtures of the Logica FM series. The LOGIC FM Control unit can
in turn be managed and controlled by a remote or local PC.
LOW-POWER RADIO COMMUNICATION BASED ON SPREADSPECTRUM TECHNOLOGY WITH UNLIMITED RADIO RANGE
ok
LOGICA Control Unit
(code 12100)
LON Interface
(code 12140)
LON
Logica Printer
(code 12099)
GSM Interface
(code 12132)
Available Interfaces:
USB (code 12136)
ETHERNET (code 12135)
RS232 (code 12134)
Personal
Computer
withRS485
CONTROL SYSTEMS
Esc
The radio waves used by the Logica FM system have very low
power to avoid any type of interference and electromagnetic
pollution. The power involved in the radio communications is less
than one hundredth of the power emitted by an ordinary cell
phone.
The signal transmitted by the Control unit is received by the first
fixture in the “path” memorized at start-up of the Control unit; each
fixture, being equipped with a radio transceiver and amplifier,
receives and transmits the signal to the fixture that follows it in the
memorized “path”.
All the products in this range comply with the requirements of
European Recommendation ERC/REC 70-03.
131
LG - Logica:
the multifunctional centralized system
AUTOMATES THE PROCEDURES LISTED
BY STANDARD UNI 11222
LOGICA is a versatile and modular emergency control system,
conceived to ensure compatibility with local and national
regulations concerning the use and checking of emergency
lighting systems. In particular Standard 11222 specifies the
procedures for the periodic checking, maintenance,
overhaul and commissioning of emergency fixtures.
-
Control unit Logica code 12100
Modular system
Fixtures operating in both AutoTest and Centraltest mode
Programmable autonomy (1hour/ 3hours)
Performance of the test may be postponed for a part of the
system (even / odd)
Wired connections (LOGICA) or radio connections (LOGICA
FM)
DALI-compatible bus for management of DALI lighting fixtures
(LOGICA)
Possibility of remote control by PC (GSM interface, Ethernet,
Usb, RS232)
Possibility of integrations with Building Automation
Centralized configuration operations
16 programmable groups of fixtures
16 programmable luminosity scenes
Emergency conversion kit (Power packs) for:
Halogen lamps with electronic and magnetic transformers
Fluorescent tubes with electronic or magnetic ballast
CENTRALIZED LOGICA SYSTEM VIA BUS THROUGH THE LOGICA SUPERVISION UNIT (up to 4096 fixtures)
The Logica Supervision Unit can manage up to 32 LOGICA
Control units for a total of 4096 emergency lighting fixtures and
DALI lighting fixtures. In turn it is possible to manage and control
the LOGICA Supervision Unit by a remote or local PC.
The LOGICA Supervision Unit adds the following functions to the
LOGICA system:
- Centralized programming and management of all the connected
Logica Control units
- Centralized printing of reports
- Logbook (memorizing the results of the functional and autonomy
tests for two years)
Personal
Computer
with RS485
LON
Available interfaces:
USB (cod. 12136)
ETHERNET (cod. 12135)
RS232 (cod. 12134)
up to 128
Esc
GSM Interface
(cod. 12132)
ok
LOGICA Central Unit
(cod. 12100)
LOGICA CT SYSTEM BY BUS (up to 128 fixtures)
The Logica Control unit allows management of both emergency
fixtures of the Logica series and DALI type lighting fixtures (Digital
Addressable Lighting Interface - International Standard according
to Regulation IEC60929) up to a maximum of 128 fixtures.
The number of Logica Control units that can be connected to a
PC is practically unlimited, thus allowing the management and
control functions of countless devices to be grouped together in
a single station.
132
up to 128
LON Interface
(cod. 12140)
Esc
ok
LOGICA Central Unit
(cod. 12100)
Logica Printer
(cod. 12099)
up to 128
Esc
ok
Esc
LOGICA Supervision Central Unit
(cod. 12131)
ok
LOGICA Central Unit
(cod. 12100)
SLG - Soccorlogica:
intelligent centralized power supply
INNOVATION AND VERSATILITY
The SoccorLogica system is a centralized power supply system
for emergency lighting with DIAGNOSTIC functions and automatic
tests of operation and autonomy.
The great versatility of the system allows fixtures already used for
ordinary lighting to be connected in an emergency, simply by
inserting the specific lamp module.
In addition to the system fixtures, SoccorLogica also integrates
fluorescent lighting fixtures equipped with an electronic control gear
or a DALI type electronic control gear, incandescent, 230V halogen
and low-voltage halogen fixtures with an electronic transformer: in
an emergency the system provides a continuous voltage at
216Vdc, assigning a single specific address in self-learning for
rapid identification. The SoccorLogica centralized battery system
allows the installation of an emergency lighting system for
structures of any size.
It is possible to integrate SoccorLogica in a BMS (Building
Management System) based on LON or KONNEX technology.
THE FIXTURE ADAPTS TO THE NECESSITY
The centralized supply and control system with which every single
lighting fixture con be controlled and supervised without any
difficulty in programming allows different operating modes, such
as: non permanent Emergency Only (SE), permanent lighting
Always On (SA). Fixtures with different operating modes can be
installed on the same line, commanded by a local switch with
timed ignition, setting or modifying the data directly from the
Control unit or be means of the specific VISUAL LOGICA software.
Using the special DALI ballast connection module, it is possible to
choose the emergency flux lamp by lamp, with limitation of the
power supplied in an emergency and consequent optimization of
the system.
SAFE AND ECONOMIC INSTALLATION
THE COMPATIBILITY OF THE LOGICA WORLD
All systems in the LOGICA series are compatible and can
dialogue with one another using the VISUAL LOGICA software.
Fixtures of the LOGICA, LOGICA FM and SoccorLogica series
can be controlled with the same instrument. The system operator
can use a single PC station to fulfil all the obligations envisaged
by the Regulations in force, and to perform commands and
controls of any type.
The VISUAL LOGICA software can control
and manage fixtures of the series
lG - lGFM - slG
133
CONTROL SYSTEMS
Each fixture is able to dialogue individually with the control unit
using the supply lines for the exchange of information by means
of powerline technology: on the power lines dedicated to the
fixtures, the Control unit sends a digital transmission coded in
such a way that it can be “heard” only by the fixture for which it is
intended. This technology limits connections and installation
cables, with an obvious saving in material and manpower.
FACILITATED DESIGN
To facilitate the designer’s and the installer’s job in sizing the
SoccorLogica, a simple configurator is available which also
checks the number of fixtures and the power per line.
THE CONTROL UNITS
The system Control unit is integrated in a metal cabinet that
contains all the system components. In systems with higher
powers there is a second cabinet containing the battery packs.
The batteries used are 216 V packs with an average life of more
than 10 years.
Each control unit has a variable number of lineS, depending on
the model.
Each output module manages 2 lines able to control up to 32
fixtures for a maximum of 690W each line. The total must not
exceed the total power of the Control unit.
The possibility of sharing the emergency lighting power supply
over several outputs, all individually protective and selective
among one another, offers a great advantage from the point of
view of safety and regulations, bringing a centralized power supply
system close to the intrinsic safety of an emergency lighting
system made with autonomous fixtures.
The emergency fixtures, or the ordinary lighting fixtures fitted with
the special lamp module, are directly connected on the line that
leaves the SoccorLogica Control unit. In the absence of mains
power, the supply to the emergency fixtures is guaranteed by the
battery packs integrated in the control unit or housed in a separate
cabinet.
• The SoccorLogica Plus Control unit has a control board with a
large display panel and a separable frame for 19” rack modules
with battery pack in a separate cabinet.
• The SoccorLogica Control unit has a control board with a
display window and a fixed frame for 19” rack modules. The
battery packs are housed directly in the bottom of the Control
unit cabinet.
134
MAIN FUNCTIONS OF THE SYSTEM:
• Possibility of control and monitoring of emergency lighting
fixtures on the same line but with a different operating mode:
- SA functions: conversion of selected fixtures, in permanent
mode
- SE function: conversion of selected fixtures, in non permanent
mode
• Non permanent mode with passage to permanent mode by
means of an external command
• Non permanent mode with selective activation of the emergency
function by external monitoring modules in the event of partial
loss of mains power
• Selective activation of the emergency function by means of
auxiliary inputs
• Complete programmability of the functions of the lamp control
modules and of the lines
• Function of automatic recognition of the lines and of the lamp
control modules installed
• Individual monitoring of 32 lamps per line
• Automatic performance of the operation and autonomy tests
• Automatic report on the tests performed.
• Storing of events for two years (LOG-BOOK)
THE INNOVATIONS OF THE SOCCORLOGICA SYSTEM
• Reduction of the number of circuits and wirings
Reduction of the dimensions of the control board
Reduction of installation costs
Simplification of design
Increased flexibility both during and after installation
Each module and each lamp is equipped with an identification
code. No manual addressing is required
• The SoccorLogica system does not require checking of an
incorrect or double address. Consequently all timing linked to
the solving of any problem is eliminated.
CC
SO
A
GIC
LO
OR
CONTROL SYSTEMS
•
•
•
•
•
135
EXAMPLE OF POSSIBLE SYSTEM CONFIGURATION
Emergency fixture selected
with conversion for
Non Permanent Lighting SE
Output module
Sign fixture selected
with conversion for
Permanent Lighting SA
Lighting fixture with lamp module
(order code 17203) integrated i
n the emergency system
MAINS
Local control
2nd FLOOR
1
Emergency fixture selected
with conversion for
Non Permanent Lighting SE
2
Sign fixture selected
with conversion for
Permanent Lighting SA
Lighting fixture integrated in the emergency system.
Switching on and off from the mains controlled
directly by the Output module
MAINS
Local control
1st FLOOR
Selectivity of intervention
in an emergency and
in case of fault
DALI
control system
Lighting fixture with DALI control gear
and DALI lamp module (order code 17204)
2nd floor mains sensor
1st floor mains sensor
8-input module
All the configurations shown in the diagram can be simply programmed by the control unit, without any change to the system, using only
the power line of the lamps, and they can be reconfigured to suit any changes in the system requirements.
136
CONTROL AND MONITORING INTERFACE
The system manages and coordinates all the SoccorLogica
systems in compliance with standards EN50171 and EN 50172.
The interface has four control buttons, one display, a multimedia
board (MMC) and a printer port.
data storage on a
multimedia board
(SD-MMC)
System function:
• Battery charging with indication of the current voltage
• Manual activation/deactivation of the inhibition of the
emergency function
• Automatic passage from normal to emergency mode in the
absence of mains power
• Selective activation of the emergency function with automatic
reset.
• Programmability of the automatic and operation tests with
automatic storage of all the test results for a duration of 2 years
• Automatic recognition of the fixtures and of the lines installed
• Automatic checking of electrical insulation for the lines and the
battery of the Control unit
LOGICA VISUAL MANAGEMENT SOFTWARE
CONTROL SYSTEMS
Software for the management of one or more
centralized emergency lighting systems of the
Series
LOGICA,
LOGICA FM
and
SoccorLogica. It is possible to import the
plans in standard formats and to complete
them with the positioning of the various
lighting and emergency devices. The video
interface allows direct action on the devices
and display of their status. It allows all the
operations contemplated by the control unit to
be performed in remote mode: a report on the
system status can be obtained automatically.
The reports can be archived, creating a
historic trace of the status of the various
systems.
137
Possibility of connection between a PC
and the SoccorLogica Control unit
• Interface USB 2.0/RS485
• Interface TCP/IP – Ethernet
• Interface GSM
Input/Output for the control and management of data:
• Numerical and graphic display of the emergency fixtures in the
plans and list of devices
• Importing of plans in .dxf and .dwg format
• Programming of data for the autonomy and operation tests
• Programming of the parameters of the LSSA inputs
• Automatic printing of the system configuration protocols and of
the errors
• Complete display of the test results
• Manual definition of the performance of operation and
autonomy tests
• Manual inhibition of emergency operation
138
On-line display function:
• Tabular and graphic display of the emergency status of each
lamp and its positioning in the plans (.dxf or .dwg format)
• Status of the fixtures
• Emergency operation mode
• Stand-by mode
• Irregularity in the system
• Tests and results
SLGS - Soccorlogica Sicuro 24V:
intelligent centralized power supply at low voltage
The Soccorlogica Sicuro 24V system is an emergency lighting
system with centralized power supply which allows the
management of lamps for emergency lighting and escape routes,
with diagnosis functions and automatic tests of operation and
autonomy, but which uses a very low safety voltage.
In compliance with regulations DIN EN 50172, the system falls
under protection class III.
The great versatility of the system allows the emergency
connection of Beghelli LED fixtures designed for the purpose, but
also of ordinary Beghelli LED lighting fixtures, simply by fitting the
specific lamp module, Sicuro 24V Inverter LED.
In an emergency the system provides a continuous voltage at
24Vdc, assigning a single specific address in self-learning for
rapid identification. The system has a centralized battery.
It is possible to integrate SICURO LED 24V in a BMS (Building
Management System) with appropriate software.
MAIN FUNCTIONS
• Possibility of control and monitoring of emergency lighting
fixtures on the same line but with a different operating mode:
- SA functions: conversion of selected fixtures, in permanent
mode
- For SA fixtures, dimmer function 10-100%;
• Non permanent mode with selective activation of the emergency
function by external input modules in the event of partial loss of
mains power
• Function of automatic recognition of the lines and of the lamp
control modules installed
• Individual monitoring of 32 lamps per line
- SE function: conversion of selected fixtures, in non permanent
mode
• Automatic performance of the operation and autonomy tests
• Automatic report on the tests performed.
• Storing of events for two years (LOG-BOOK)
IP43
LUNGLARGALUCE LED - recessed
IP42
LUNGLARGALUCE LED - ceiling
IP20
IP20
M600 I418 LED
FORMULA 65 LED
P236/P258 LED
LED MODULE
WITH CONVERSION KIT
D170/1150 LED ADJUSTABLE
F250/400 LED
IP66
ACCIAO LED
IP44
IP20
IP20
DWL D226 LED
IP66
IP66
H 250/400
INDICA LED
IP44
IP20
IP20
D1150/170 LED
IP40
IP41
IP40
IP65
WW170/1150 LED
IP66
IP66
FH 70/150 LED
F50 LED
139
CONTROL SYSTEMS
FIXTURES AVAILABLE IN SLGS VERSION
slG sicuro control unit
THE ELEMENTS
• Device for automatic control and monitoring, in compliance with
standard EN 62034. Monitoring is carried out by means of two
types of tests. The shorter one evaluates the perfect operation
of the system (functional test) and the more detailed one
evaluates the emergency autonomy (duration test). The test
results are stored in the SicuroLED device.
• Charger 27.2 V / 3A 27.2V / 5A, 27.2V 10A
• Automatic emergency activation in the absence of mains
power. The system also allows the emergency to be managed
autonomously on the various system sections.
• The mains presence on the distributions is indicated to the
system by single-phase or three-phase mains sensor devices.
They are fitted downstream from the differentials/disconnecting
switches and monitor the single phase or the three phases.
• Each SicuroLED Control unit manages up to 128 lamps,
subdivided into 4 lines of maximum 32 lamps each. Main
characteristics and functions of the system:
- integration of SE and SA functionality
- Univocal and automatic addressing of the lamps
- Targeted monitoring of the single lamp
General
characteristics
Protection Class I
Protection degree IP20
Autonomy 1h - 3h, 1-2.20h
Working temperature -5°C ÷ +25°C
Autonomy 1h - 3h, 1-2.20h
Battery 24V DC
Power supply 1~N/PE, 230V
AC +-10%, 50/60Hz
- In the presence of mains power, the lamps can be dimmed
from 10% to 100%
- SA lamps can be switched on or off directly by the control
unit, or by remote control by means of the input module 3+5
- In case of maintenance on the mains it is possible to time the
switching on and off of the lamps
• 3 relay outputs (programmable) for indicating:
- battery charging error
- battery error
- lamp error
- reaching minimum battery threshold
• RS485 interface for:
- interfacing max 2 input modules
- interfacing monitoring with optional Sicuro-Visual software
• ETHERNET interface for communication via
• USB interface for uploading and downloading the system
configuration, the results of the tests performed, and for
updating the software of the system and of the SicuroLED
modules.
• Lead batteries, life expectancy 10 years at working temperature
20°C.
140
profondità
140
636
644
profondità
140
17063
800
808
17062
514,5
522
17061
800
808
17060
ord. code
profondità
170
profondità
170
316
316
400
400
colour
RAL9003
RAL9003
RAL7035
RAL7035
battery
12 Ah
24 Ah
28 Ah
56 Ah
6.1A 147.2W
12A 288W
12A 288W
12A 288W
discharge current
1h
2h
3.4A 82.4W
7.5A 180.8W
9.4A 226.4W
12A 288W
3h
2.2A 53.6W
5.1A 123.2W
7A 170W
12A 288W
2x12 Ah
4x12 Ah
2x28 Ah
4x28 Ah
output circuits
4
4
4
4
max current
3A
3A
3A
3A
power supply
2.5
2.5
2.5
2.5
fixtures
2.5
2.5
2.5 / 4
2.5 / 4
number of batteries
MAX SECTION OF LEADS
data
2.5
2.5
2.5
2.5
24V external devices
2.5
2.5
2.5
2.5
light switches (LSSA)
2.5
2.5
2.5
2.5
inputs
2.5
2.5
2.5
2.5
outputs
2.5
2.5
2.5
2.5
signalling contacts
2.5
2.5
2.5
2.5
pre-cut membrane
pre-cut membrane
pre-cut membrane
pre-cut membrane
15
25.7
37.5
56.5
top
rear
weight (with battery) kg
CONTROL SYSTEMS
CABLE INLETS
Maximum cable length for max voltage drop of 3.5V
maximum voltage drop
3.5V
protection fuse
5A
load (A)
section (mm2)
length (m)
maximum load for output circuit
3A
3
1.5
49
2
1.5
74
1
1.5
147
3
2.5
82
2
2.5
123
1
2.5
245
141
EXAMPLE OF POSSIBLE SYSTEM CONFIGURATION
L1
L2
L3
N
DWL226
DWL226
M600 I418LED
M600 I418LED
ACCIAIO LED
ACCIAIO LED
SICURO VISUAL
Indica
Indica
Lungalargaluce
Formula 65 Led
Formula 65 Led
Lungalargaluce
All the configurations shown in the diagram can be simply programmed by the control unit, without any change to the system, using only
the power line of the lamps, and they can be reconfigured to suit any changes in the system requirements.
142
THE INNOVATIONS OF THE SOCCORLOGICA SICURO SYSTEM
• Reduction of the number of circuits and wirings
• Reduction of the dimensions of the control board
• Reduction of installation costs
• Simplified design
• Each module and each lamp is equipped with an identification
code. No manual addressing is required
• The SoccorLogica system does not require checking of an
incorrect or double address. Consequently all timing linked to
the solving of any problem is eliminated.
• Increased flexibility both during and after installation
CONTROL AND MONITORING INTERFACE:
ELEGANT TOUCH-SCREEN
The system manages and coordinates the system in compliance
with standards EN50171 and EN 50172. The interface is an
elegant and intuitive touch-screen with the following functions:
• Battery charging with indication of the current voltage
• Manual activation/deactivation of the inhibition of the
emergency function
• Automatic passage from normal to emergency mode in the
absence of mains power
SICURO VISUAL MANAGEMENT SOFTWARE
Software for the management of one or more centralized
emergency lighting systems of the Series SoccorLogica Sicuro
24V. It is possible to import the plans in standard formats and to
complete them with the positioning of the various lighting and
emergency devices. The video interface allows direct action on
the devices and display of their status. It allows all the operations
contemplated by the control unit to be performed in remote
mode: a report on the system status can be obtained
automatically. The reports can be archived, creating a historic
trace of the status of the various systems.
• Selective activation of the emergency function with automatic
reset.
• Programmability of the automatic and operation tests with
automatic storage of all the test results for a duration of 2 years
• Automatic recognition of the fixtures and of the lines installed
CONTROL SYSTEMS
• Automatic checking of electrical insulation for the lines and the
battery of the Control unit
143
4
4
2
4
2
1
4
2
1
Lungalargaluce LED
Emergency Lamp
2
144
3
4
Fruttoluce LED
Indica LED
Formula 65 LED
Emergency Lamp
Sign Lamp
Sign Lamp
Examples of mounting
Local control system
AT
1
3
1
CONTROL SYSTEMS
3
The simplest system in compliance
with standard UNI 11222
The UNI 11222 standard defines the procedures for running
periodic controls, maintenance, overhaul and commissioning of
safety lighting equipment in buildings, composed of emergency
lighting fixtures, both autonomous and centralized. The Standard
requires almost everywhere the use of fixtures and/or emergency lighting
systems that allow automatic checking of their effective autonomy.
It also specifies that the registrations effected by automatic diagnostic
systems constitute a valid input to the compilation of the periodic controls
register. Even for moderate size systems it is therefore absolutely recommended
to use at least Autotest fixtures, which from the economic point of view are now
comparable to normal traditional emergency fixtures.
145
1
2
3
4
lens
Lungaluce
lens
Largaluce
Lungalargaluce LED
Lungalargaluce LED
Fruttoluce LED
Indica LED
Emergency lighting
Emergency lighting
Extractable Emergency Lamp
Signal Fixtures
5
6
6
6
Logica LED
LG-LGFM control unit
SLG control unit
SLGS control unit
Emergency lighting
Control and Diagnosis System
Control, Diagnosis and Power supply
Control, Diagnosis and Power supply
5
6
2
1
4
4
4
1
4
4
2
4
3
1
3
4
3
146
Centralized control system
LG - LGFM - SLG - SLGS
3
3
5
3
3
4
1
4
4
3
3
4
2
3
3
CONTROL SYSTEMS
3
Completeness of control and management, both with self-powered systems and with
centralized power supply
When the system starts to have important dimensions (on average more than 30-40 fixtures installed), it is
necessary to aim for systems with centralized self-diagnosis such as Logica and Logica FM which have
the advantage of concentrating the results of the periodic tests in a single station. Logica FM also offers
the extraordinary convenience of not having to lay additional connections besides the ordinary mains
power supply cables. This characteristic makes it possible to install an emergency lighting system with
centralized control even on existing systems, without making any alterations to the electrical system since
a dedicated data line is not necessary.
Instead SoccorLogica allows the concept of emergency lighting with diagnostics to be extended also to
systems with a centralized power supply.
147
The Academy
for professionals
ACCADEMIA
Workshops, documentation and services to support design
Beghelli Accademia is a space for knowledge and exchange, at
the disposal of professionals in lighting design.
A space where they can:
- investigate every aspect of LIGHT, the principal theories, the
legislation, the technical solutions
- train in workshops organized throughout the national territory
- find a tangible support service for their design activity
A special section of Beghelli Academy is active on-line, accessible
from the home page of beghelli.it, where a collection of
148
publications, technical documentations and useful support for
design studios can be found, the contents of which are updated
regularly. The dates, programmes and final reports of the
workshops are published in this area.
An electronic catalogue can also be consulted, containing full
information on the Beghelli offer. The technical data sheet of every
single fixture is published, with the image, product code,
photometric curve, assembly instructions, text for specifications,
energy classification, taken from the respective catalogue. Lastly a
tangible support service for their design activity is available.
For information and sending projects: accademia@beghelli.it
Photometric Diagrams
and Luce Utile
logica leD
Logica LED
6-8-11-24 W
cd/klm
135°
150°
165°
180°
165°
150°
135°
250
200
120°
120°
150
The figure in lux refers to the value of illumination on the ground
that the fixture can reach, with a predetermined installation height.
Instead the figure in metres corresponds to the surface (side x
side) that the fixture illuminates with the minimum value required by
Standard EN 1838.
The combination of the two figures therefore provides the
elements for an immediate evaluation of the lighting characteristics
of each emergency lamp.
100
105°
105°
90°
90°
75°
75°
60°
60°
45°
30°
15°
0°
15°
30°
C0-C180
45°
C90-C270
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H6m
W
lx
8
11
24
5.32
6.64
7.97
m
lx
7x4
7.5x4.5
8x5
3.49
4.36
5.24
m
lx
m
11x5
12x6
13x6
1
1.2
13x3
15x4
lx
0.72
0.90
1.09
m
14x8
15x8
15x9
Formula 65 leD
FORMULA 65 LED
6-8-11-24 W
cd/klm
105°
105°
90°
90°
75°
75°
60°
60°
160
240
45°
45°
320
30°
15°
0°
15°
C0-C180
30°
C90-C270
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H6m
W
lx
6
8
11
24
1.42
1.55
2.90
m
6x4
lx
1.08
1.70
1.86
3.48
m
5.5x4
6x4.5
8x6
lx
m
lx
1.00
-
.
0.50
0.88
m
8x10
149
Granluce leD
Granluce leD
GRANLUCE LED
6-11 W
GRANLUCE LED
8-18-24 W
cd/klm
cd/klm
105°
105°
105°
105°
90°
90°
90°
90°
75°
75°
75°
60°
60°
60°
75°
1000
60°
1600
45°
1500
45°
2400
2000
45°
45°
2500
3200
3000
30°
15°
0°
15°
30°
30°
C0-C180
C90-C270
15°
0°
lx
6
11
2.19
3.19
m
5x12
5.5x2.5
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H6m
lx
m
lx
m
lx
m
W
lx
1.20
-
-
-
.
-
8
18
24
2.64
4.61
5.77
leD module
m
lx
5.5x12
6.5x12.5
7.5x13
1.08
1.35
m
lx
m
lx
m
5.5x1.5
7x2
-
-
-
-
leD module
MODULO LED
Lungaluce Lens
MODULO LED
Largaluce Lens
cd/klm
135°
30°
C90-C270
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H6m
W
15°
C0-C180
cd/klm
150°
165°
180°
165°
150°
135°
105°
105°
90°
90°
75°
75°
3000
2500
120°
120°
2000
1500
1000
105°
105°
60°
90°
90°
75°
75°
60°
60°
60°
320
45°
45°
480
640
45°
30°
15°
0°
15°
C0-C180
30°
30°
45°
C90-C270
15°
0°
W
lx
m
lx
24
-
-
2.44
30°
C90-C270
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
150
15°
C0-C180
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
m
lx
m
lx
m
W
lx
m
lx
m
lx
m
lx
16.5x2
-
-
-
-
24
-
-
-
-
-
-
0.94
m
12x12
leD module
lungalargaluce leD
LUNGALUCE LED
Lungaluce Lens
MODULO LED
lente Altaluce
cd/klm
cd/klm
105°
105°
90°
90°
135°
150°
165°
180°
165°
150°
135°
3000
2500
120°
75°
75°
1500
1000
105°
60°
120°
2000
105°
60°
300
400
45°
45°
500
90°
90°
75°
75°
60°
60°
600
30°
15°
0°
15°
C0-C180
30°
45°
30°
15°
0°
15°
30°
C0-C180
C90-C270
lx
m
lx
m
lx
24
-
-
-
-
0.70
RECESSED/CEILING VERSION
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
W
45°
C90-C270
m
lx
m
W
lx
m
lx
12x12
-
-
24
-
-
2.44
lungalargaluce leD
m
lx
m
lx
m
16.5x2
-
-
-
-
lungalargaluce leD
LUNGALUCE LED
Largaluce Lens
LUNGALUCE LED
Diffusaluce Lens
cd/klm
cd/klm
105°
105°
105°
105°
90°
90°
90°
90°
75°
75°
75°
60°
60°
60°
75°
100
60°
320
45°
150
200
45°
45°
480
45°
250
640
300
30°
15°
0°
15°
C0-C180
30°
30°
RECESSED/CEILING VERSION
15°
0°
15°
30°
CEILING VERSION
C90-C270
C0-C180
C90-C270
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
W
lx
m
lx
m
lx
m
lx
24
-
-
-
-
-
-
0.94
Luce Utile: Illumination value (Lux) and illuminated surface (m)
H 2.5 m
H3m
H6m
H3m
m
W
lx
m
lx
m
lx
m
lx
m
12x12
24
1.16
-
-
-
-
-
-
-
151
Luce Utile Beghelli
Useful Light fixtures, according to Beghelli standardization, ensure a precise illumination (Lx) on the ground if installed at the
distance contemplated by the Luce Utile project and indicated next to the icon that specifies the direction and width of the beam
of light. It is possible to simplify the definition of the lighting characteristics of a fixture using the only useful value for design
purposes: the illumination on the ground expressed in Lux. To guarantee this value it has been necessary to define the dimensions
of some typical installation situation, cataloguing each product not according to its luminous flux, but supplying the various
illumination values in the various conditions of use for which the fixture was designed.
The value is available only on some products and can be found in the technical annex, from page 136 onward
escape route wall mounting
H 2.5 m
Chosen configuration: Corridor of indefinite length, width 2m, height 3m. Mounting height
2.5m. Horizontal WALL mounted fixture. The area on which the illumination fraction is calculated
is along the escape route defined by EN1838 for a total extent of 5sq.m. The configuration
chosen is attributable to most wall installations on escape routes. The calculations refer to the
ground and are made without reflections with a maintenance factor of 0.8.
EN 1838: minimum 1 lx along the central line.
3m
2,5 m
5m
1m
2m
escape route ceiling mounting
H3m
Chosen configuration: Corridor of indefinite length, width 2m, height 3m. Mounting height 3m.
Fixture mounted on the CEILING with main axis transverse to the larger axis of the premises.
The area on which the illumination fraction is calculated is along the escape route defined by
EN1838 for a total extent of 5sq.m.
The configuration chosen is attributable to most ceiling installations on escape routes. The calculations
refer to the ground and are made without reflections with a maintenance factor of 0.8.
3m
5m
1m
2m
EN 1838: minimum 1 lx along the central line.
H6m
6m
5m
1m
2m
large areas ceiling mounting
H3m
The area on which the illumination fraction of usable illumination is calculated in the safety
lighting of Large Areas as anti-panic lighting is comprised in a room of indefinite width and
length, height 3 metres, product mounting height 3 metres. The area on which the useful
illumination is defined is enclosed in 25 sq.m below the product. The calculations refer to the
ground and are made without reflections with a maintenance factor of 0.8.
EN 1838: minimum 0.5 lx on the entire area.
3m
5m
5m
escape route ceiling mounting
H6m
152
Chosen configuration: Corridor of indefinite length, width 2m, height 6.5m. Mounting height
6m. Fixture mounted on the CEILING with main axis parallel to the larger axis of the premises.
The area on which the illumination fraction is calculated is along the escape route defined by
EN1838 for a total extent of 5 sq.m. The configuration chosen is attributable to most ceiling
installations on escape routes with height 6m. The calculations refer to the ground and are
made without reflections with a maintenance factor of 0.8.
EN 1838: minimum 1 lx along the central line.
6m
5m
5m
It does not matter how much light a fixture emits.
What makes it important is what its light shows,
transforming it into a useful lighting fixture.
All the light outside the controlled beam is just a waste of
energy.
LuceUtile
Project
The new era in emergency lighting
The highly technological identity and the value of the Beghelli
brand are fully expressed in the project for the renewal of
emergency fixture light sources. The use of high-efficiency LEDs
and a calibrated light beam produces adequate lighting while
maintaining very high energy saving.
The Luce Utile (Useful Light) philosophy springs from the need to
obtain an ideal beam of light for emergency lighting that gives the
maximum possible light output. The optics have been specially
designed to solve lighting problems on the ground with a smaller
number of fixtures, respecting the values envisaged by the
regulations in force.
153
Environmental protection
WEEE DIRECTIVE 2002/96/EC
The quantity of waste derived from electrical and electronic equipment (WEEE) is increasingly rapidly and
a large part consists of light sources (excluding incandescent filament lamps).
The main objective of the directive is to prevent WEEE thrown, at the end of their working life, into landfill
or incinerators, causing a further serious impact on the environment.
Directive 2002/96/EC has therefore sought to introduce a control mechanism which envisages a
controlled management of the device at the end of its working life, to encourage its reuse or recycling.
The legislative mechanism also promotes design and production concepts that make product disposal
easier, in terms of both disassembly and materials.
In the case of lamps, the financing of activities connected to the collection, management and recycling
of WEEE at the end of their working life is guaranteed by a visible fee applied at the moment of sale.
All passages in the commercial chain are required to make a contribution, some in economic terms, some
in terms of activity, to ensure that the spirit of the directive is respected (and the environment is
protected).
In Italy the directive was acknowledged with decree 151 of 25 July 2005 and subsequently integrated in
other implementing decrees.
THESE ARE THE PRINCIPAL OBLIGATIONS ENVISAGED
The producer (understood in the broad sense and therefore substantially whoever applies his brand on
the goods and who imports from another country) is responsible for the costs of disposal of his products
at the end of their working life.
The sales outlet is required to collect the product at the end of its working life if it replaced by a new one
of the same kind.
The consumer is required to manage the item sensibly at the end of its life, consigning it to an equipped
collection point, a sales area, or following the manufacturer’s indications.
Beghelli has always been aware of the environmental problem and is one of the founder members of the
ECOLIGHT consortium, to which the company consigns all the collected visible contribution.
Choosing products and companies that rely on voluntary consortiums for the recovery and recycling of
products is a responsible and ecologically correct choice for the protection of the environment and for our
future.
The products that fall within the field of application of the WEEE directive are identified by the symbol
alongside (there is also the version not crossed-out).
RHOS DIRECTIVE 2002/95/EC
In order to facilitate the recovery and recycling of electrical equipment and to avoid the accumulation of
hazardous substances in the environment, the European community issured the RHOS directive,
acknowledged in Italy with the same decree as the WEEE directive, that is DM 151 of 25 July 2005. The
Directive was rewritten and issued with reference 2011/65 with new obligations for producers in terms
of documentation. The substantial provisions remain unchanged:
Without prejudice to annex 5, as from 1st July 2006 it is forbidden to launch on the market new electrical
and electronic equipment falling under the categories identified in annex 1A, as well as incandescent light
sources containing lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBBs) or
polybrominated diphenyl ether (PBDE).
162
Exceptions and exemptions to this regulation are contemplated, in particular the veto on mercury is not
applied to compact fluorescent lamps and fluorescent tubes containing mercury in quantities not
exceeding the allowed limits. Other exceptions are contemplated and are continuously updated. For
details see the site www.ec.europa.eu/environment/waste/rohs_consult.htm
All Beghelli products and lamps first of all are made in compliance with the ROHS Directive, as rewritten
in 2011
General terms of sale
1. ORDERS - FINALIZATION OF AGREEMENTS
7. COMPLAINTS - REPLACEMENT OF PRODUCTS
Product purchase orders must be made in writing. Placing of an order is considered irrevocable. The
Seller reserves the faculty to fulfil orders also in part, or to cancel them, even any residual part, in the
event of a change of the situation of the Buyer. All collaboration programmes, orders, commissions and
agreements are intended as finalized with the written or verbal confirmation by the Seller, or at any rate
with the start of invoicing and/or delivery of the products ordered.
For replacements and complaints the safeguards contemplated by the law are applied, applicable to the
specific type of customer, professional operator or consumer. As soon as the products are received, the
Buyer is required to check the condition, the quantity of the supply and to ensure that it corresponds to
the delivery note. Any complaints concerning quality, quantity or type of product must be made in writing
within 8 (eight) days of the date of receipt of the goods. Once that time has expired, and without prejudice
to the various guarantee conditions envisaged for the individual products, no complaint can be made
regarding the substance and quality of the goods, or for their general conditions. The Buyer may for no
reason return the products without prior authorization of the Seller in writing, nor delay and/or totally or
partially suspend payment of the invoices, not even in the case of complaints. Should there be grounds
for the complaint, in the Seller’s opinion, and if it has been made within the guarantee terms indicated in
the illustrative booklets that accompany the individual products, the guarantee obligation is limited to the
simple replacement of the non conforming product according to the delivery procedures of the first
supply. Any right of the Buyer to cancel the order or to obtain any refund for expenses and/or damages
is therefore excluded. The right to replacement of the disputed product expires if the product is not kept
diligently, at the Seller’s disposal, and immediately returned to the place established by the Seller.
2. VARIATIONS AND MODIFICATIONS
After finalization of the order, any modification or integration of the content and terms of the order shall
be valid and become effective only when the Seller sends the Buyer a variation of the confirmation. The
text of the confirmation or of the variation of the confirmation by the Seller shall prevail in any case over
any other document.
Should the Buyer not wish to accept the terms that differ from his order, he must point it out within 20
(twenty) days of the date of confirmation, otherwise the variation of confirmation shall be deemed
accepted in full.
3. ACCEPTANCE PROCEDURE
The Seller cannot be held liable for non acceptance of an order, or for non delivery or delayed delivery of
the products ordered. The acceptance and execution of the order are specifically subordinate to the
availability of the products ordered and to the absence of circumstances that could in any way influence
their availability and the promptness of their delivery.
The prices indicated in the Seller’s price lists are not binding, consequently the Seller reserves the right
to modify them until the time of delivery of the products.
The prices are net of VAT and of any other fiscal dues.
4. DELIVERY TERMS
9. PAYMENTS
The delivery terms communicated by the Seller are purely indicative.
The delivery terms expressed in days are normally calculated in working days.
Any modifications to the delivery terms requested by the Buyer must be accepted in writing by the Seller.
Any delays in delivery, and any interruptions and/or total or partial suspensions of delivery, even if not
due to force majeure and/or act of providence, shall not entitle the Buyer to claim a refund for damages
and/or compensation of any kind nor even interest; the Buyer shall have the sole faculty to cancel the
order upon written notice to the Seller of at least thirty days counted from the date of receipt of the
registered letter with recorded delivery sent by the Buyer.
All payments must be made at the times and with the methods indicated by the Seller to the latter’s
headquarters at Monteveglio (Bologna) or to the person indicated and duly authorized in writing by the
Seller. In the case of a delay in payment, the defaulting buyer shall be required to pay the Seller interest
for arrears from the due date of the contractual term until the date of settlement, according to the primerate in force at the time (as determined by the Italian Banking Association - ABI) plus 5 (five) points,
without prejudice to claims for further loss. Failure by the Buyer to respect the terms of payment shall
entitle the Seller to terminate the respective supply contract with immediate effect and to suspend
delivery of all products that may be ordered without the need for any communication, with the consequent
right for the Seller to demand the immediate payment of the entire credit and to take action for the
compensation of damage suffered.
Without limitation, the following are to be considered causes of force majeure: strikes, lockouts, rebellion,
labour conflicts, fire, natural calamities, impossibility to provision products, interruptions or difficulties in
transport, delayed deliveries, lack of raw materials, actions of the government and authorities, failure of
suppliers and, in general, any unforeseeable event which cannot be reasonably considered to be under
the control of the Seller. In all such cases, as in the event of act of providence, the Seller reserves the
faculty to suspend and/or delay the delivery of the products and even to cancel the orders, even if already
confirmed, without this entitling the Buyer to claim a refund from the Seller for damages and/or
compensation of any kind, including direct, indirect and consequential damage.
6. DELIVERY - TRANSPORT
The goods always travel at the Buyer’s own risk, even when sent carriage paid and/or with the Seller’s
vehicle, so the Seller shall not accept any complaints for any breakages and/or tampering with the
products. Delivery of the products is considered made from the headquarters of the Seller at Monteveglio
(Bologna).
Transport expenses are borne by the Buyer. The Seller does not accept returned packaging.
Beghelli products are manufactured to state-of-the-art standards in terms of safety, in compliance with the
requirements of laws 186/68 and 791/77, and do not compromise the safety of persons, pets or property,
if installed and used according to their intended purpose and correctly fitted. Moreover, the products that
fall within the field of application of the EEC Directives (“EMC” Directive 89/336/EEC - acknowledged with
Law Decree 476/92 - amended by Directive 93/68/EEC and the “BT” Directive 73/23/EEC - acknowledged
with Law 791/77 - amended by Directive 93/68/EEC) comply with the essential requirements contained
therein. The CE mark applied on the product and/or on the packaging and/or on any warnings for use that
accompany the product “indicates presumed conformity with the Directives” mentioned above. Beghelli
keeps a Technical Archive, at the disposal of the competent authorities for any inspections, containing the
documentation demonstrating that the produce has been examined to assess its conformity.
concessionario
Marchio iMQ
10. LIEN AGREEMENT
The products are sold under a lien agreement; they shall therefore remain the property of the Seller until
full payment has been made.
The Buyer therefore undertakes to inform third parties of the existence and efficacy of this lien
agreement, and to safeguard the Seller’s rights deriving therefrom.
11. COMPETENT COURT
For any controversy or dispute concerning the interpretation, validity and execution of the order, or
connected in any way to the contracts to which these general terms of sale apply, the exclusive
competent court shall be the Court of Bologna.
The data contained in this catalogue may be subject to variation without notice. All the products included
are covered by the Beghelli guarantee according to the laws in force, unless indicated otherwise in the
guarantee supplied with every single product.
The products for Building Automation, Air Conditioning and Anti-intrusion are included in the “Intelligent
Beghelli” catalogue. Energy saving lamps, Air Treatment, Remote Assistance, Safety, Portable Lighting,
Health and Safety for Infancy, are included in the “Beghelli Commercial Line” catalogue.
All the above-mentioned catalogues are available on the site www.beghelli.com or may be
requested from: Beghelli S.p.A. - Sales Management - Via Mozzeghine, 13/15 - 40053
Valsamoggia loc. Monteveglio - Bologna
associato:
© copyright 04/2015
5. FORCE MAJEURE
8. PRICES
163
Download