DSX-1034 Intelligent Input Controller Ñ 32 Programmable 2, 3 and 4 State monitoring points Ñ Flexible I/O Linking - Local & Panel to Panel Ñ UL 294 Listed Ñ LED status for each Input break detectors. It can also be used to monitor other systems such as HVAC or lighting systems. The DSX-1034 can even be used to monitor temperature sensors, water level sensors, gas sensors or any other device providing a dry set of contacts. With the linking capabilities of the WinDSX System almost any requirement for input and output control can be met without the use of external timers or relays. Controller Architecture Ñ Incremental Downloading of changes only The DSX-1034 Intelligent Controller is comprised of a 1030P Processor and a 1034I/O Termination Board. The 1030P contains the V20 processor, ROM and RAM memory. The 1034I/O contains the power supply and removable field wiring terminals. The DSX-1034 has 32 EOL supervised inputs for point monitoring. The 1034 has 4 programmable open collector outputs that are programmed and utilized the same as all other controller outputs. Ñ Point to Point RS-485 4-wire Panel Communications Memory Ñ 4 Time/Day Schedules per Input/Output Ñ Real Time Clock and Calendar for Input Control The DSX-1034 has a standard configuration of 64K of ROM and 64K of RAM. The RAM memory allocation is dynamic between database and event storage and set for optimum use by the Host PC according to data entered for that location. The RAM memory may be expanded from 64K to 192K by adding up to four 32K RAM chips. When upgrading the ROM in this panel to the new operating it may be necessary to add a single RAM chip due to the new operating system having slightly higher memory requirements. When the panel is in service the amount of RAM and the version of ROM can be viewed from the DSX communications software. Inputs The DSX-1034 has 32 supervised inputs used for alarm monitoring. Each input has an LED to indicate its electrical status regardless of the armed state. One of the inputs must be connected to the door tamper switch and programmed with a 24-hour Time Zone for U.L. Installations. Each input on the DSX-1034 can be controlled with up to 4 Time Zones. This allows the inputs to be armed and disarmed up to four times per day. General Applications The DSX-1034 is engineered for those applications where large numbers of inputs are needed. This 32 input controller could be for alarm and other point monitoring and control. There are many applications for the DSX-1034. The 1034 can be used to monitor door and window contacts, motion detectors, panic buttons, and glass Each Input has an individual Abort Delay Time. The Abort Delay Time determines how long the input has to be faulted before it goes into alarm. Each input can optionally have a shared or unique Action Message. The action message displays on the PC and instructs the operator on what action to take when the input goes into Alarm. The inputs on the DSX-1034 support two, three and four state monitoring, with five input configurations to choose from. Three and Four state input circuits support trouble conditions. DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 888-419-8353 Phone 214-553-6140 Phone 214-553-6147 Fax www.dsxinc.com Outputs The DSX-1034 has 4 Outputs. These Outputs are open collector rated at 100ma. The Outputs can be controlled by up to 4 time zones each which provides the ability to turn each output on and off up to four times per day. Each Output of the DSX-1034 can be individually set for fail-safe or fail secure. The 4 outputs can be expanded to 8 or 16 with the addition of a DSX-1036 (4 relays) or a 1033EX (12 relays) output extender module. Communications: The DSX-1034 Intelligent Controller can communicate with the Comm Server (Host PC) via direct serial port connection or dial-up modem communications. Direct Connect Communications to the PC from the Master 1034 Controller is performed with either RS-232 or RS-485 since the controller has a dual host communications port. The RS-232 host port is used for short distance direct serial port connections. The RS-485 host communications port is used when the direct serial port connection is from 50 to 4000 feet from panel to PC. A DSX MCI module can be placed at the PC to covert the RS-232 signal to RS-485. The controller communicates with the PC at a default baud rate of 9600. As long as the communications signal arrives at the Master as RS232/485 and RS-232 at the PC in an asynchronous, full duplex mode, operating at 9600 baud, the method in between can be just about any mode of transport such as Direct Wire, T1, Lease Line, or Fiber Optics. speed of the panels actions and reactions, providing more stability and security to the overall system. The Controllers are downloaded with all parameters the first time they are brought on-line. Once the initial full download occurs all database changes such as the adding and deleting of card holders are sent to the controllers by way of incremental downloads. In other words the panels are downloaded just the changes and only require a full download on power up or in the event that the system data integrity check determines there is a discrepancy in the synchronized database held by one of the panels. Diagnostic, Supervisory and Status LEDs The DSX-1034 has 51 diagnostic LEDs to indicate panel status. Thirty two are for Input Status, four are for Output Status, two are for panel to panel communications, two are for PC to Master communications, one for AC power input Status, five are for Processor Status, two are used for Power Supply Fuse Status, two for High and Low AC Power and one for Low Battery. High and Low AC and Low Battery report to the PC as alarms. Input / Output / Code Linking The DSX-1034 Intelligent Controller has new Linking capabilities that provide even greater input and output control. All I/O Linking is performed at a local level as well as a global level. This is the ability for inputs, outputs, and cards from one controller to link to inputs and outputs on any and all other controllers in the location without the PC being on-line. It also allows each panel to link to its own inputs and outputs when panel to panel communications are down. Dial-Up Modem Communications from the DSX-1034 Master Controller to the PC utilizes a DSX 9600 baud modem at the Controller and the same modem at the PC. At the 1034 Master, the RS-232 Host Communications Port connects to the Modem. The Modem derives its power from the 1034 panel. The Controller will auto-dial to the PC all Alarm and supervisory conditions. The controller can also be programmed to dial the PC when its event storage buffer is 80% full. Codes, Inputs, and Outputs can Link to other Inputs and Outputs, on the same or different controller, in order to control their armed or on and off state. Linking to inputs allows for control of their armed state. Linking to outputs allows for control of their on and off state. Inputs can Link to Inputs and Outputs. Outputs can link to Outputs and Inputs. Codes can link to both Inputs and Outputs. Panel to Panel Communications is a true point to point, regenerative, RS-485, 4-wire communications method. This allows the panel to panel network communications to be regenerated at each controller allowing up to 4000 feet of distance between controllers over two twisted pair cable. Panel to Panel communications can be configured in a series loop, star configuration, or both. The panels are wired in a series loop configuration unless a DSX-1035 Quadraplexor is used. With the DSX-1035, a STAR wiring configuration can be achieved. The Quadraplexor can be placed anywhere on the RS-485 circuit after the Master panel to provide four RS-485 branch loops. Any number of panels can be placed on each RS-485 loop without regard to panel address. The Links can be responded to in 1 of 5 ways. The responses can be Toggle, Pulse, Latch, Time Zone, and Follow. Inputs can initiate a link on the transition from normal to abnormal or on an alarm condition. Outputs can initiate a link on the transition from on to off or from off to on. Outputs can be used as software timers to control a delay-on link to other inputs and/or outputs. For example an input, output or code initiates a link to an output which pulses the output from 1 - 999 seconds or 1 - 546 minutes. The output links secure and when the pulse timer expires the output returns open thereby initiating a subsequent link to an output group consisting of inputs and/or outputs. If the first output continues to receive a link its pulse time gets reset. DataBase Downloads The linking state of the relay outputs should be carefully planned in elevator and HVAC control systems. The linking state of the relays should be set so that when the relays are open (de-energized), the elevator or HVAC system is active, not disabled. This will ensure a fail-safe system. It is always advised that the outputs be energized to disable a function and de-energized to enable a function. The Controllers utilize a synchronized database that is maintained with the incremental and automatic or scheduled downloading of changes only. This intelligent independent processing increases the DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 888-419-8353 Phone 214-553-6140 Phone 214-553-6147 Fax www.dsxinc.com DSX-1034 Specifications Size Cabinet 1030P 1034I/O 16.0" W x 20.0" H x 4.375" D 8.5" W x 8.75" H x 2.0" D 8.75" W x 14.0" H x 2.5" D Cabinet 1030P 1034I/O Package Total 16.00 lb. 2.00lb. 5.50lb. 23.50 lb. Weight Finish Black Powder Coat with White Silkscreen. Temperature Operating Storage 32 to 131 F -35 to 150 F Operating 0 to 95%, relative Humidity Supply Voltage Panel Voltage 16.5 VAC 40VA Power Requirements 33 Watts (.031 BTU) Panel Current Draw 700 ma (Current will vary depending on panel voltage output loads). UL Listed or CSA Certified Class II Transformer Required. Output Voltage Modem Power Aux 12 Inputs 9VDC 300ma - current limited 12VDC 1A - fused Supervised 32 UL Installations require a Tamper Switch to be connected to an Input programmed with a 24hr Time Zone. Outputs Programmable 4 100 ma - Open Collector / expandable with 1036 (4) and 1033EX (12) Output extender Modules Battery Charging Output Trickle Charge 13.5 VDC 500ma Fused Standby Time for the 1034 under Maximum Load is 3.5 hours. For UL Installations, battery must be Powersonic PS-1270 or an Interstate PC-1270. Communication Ports RS-232 In RS-485 In RS-485 Out 1 2 1 Intel 80C88 or V20 8Mhz Processor RAM Memory Master to PC 1 for Master to PC, 1 From Slave To Subsequent Slaves Standard 64K Expandable to 192K with the addition of up to 4 32K RAM chips * The transaction buffer automatically adjusts to utilize any RAM not allocated for system parameters. Packaging The DSX-1034 comes complete with 1034I/O, 1030P, Ribbon Cable, 32-1K ohm EOL Resistors, Enclosure, Lock & Key, Anchors and Wire Ties, Tamper Switch, and External AC Power Indicator. DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 888-419-8353 Phone 214-553-6140 Phone 214-553-6147 Fax www.dsxinc.com DSX-1034 Typical Connections Input Circuit Type 0 1k E.O.L. 1 1k E.O.L. Normally Open & Normally Closed Circuit Short = Alarm Circuit Open = Alarm No Trouble Input Circuit Type 1 1k E.O.L. 1k E.O.L. 1k E.O.L. 2 INPUT 1 3 INPUT 2 Input Circuit Type 4 1034 ALARM INPUT PANEL SIDE A SIDE B 1 INPUT 1 2 INPUT 2 3 LED ON = INPUT NORMAL LED OFF = INPUT ABNORMAL 4 4 5 INPUT 3 INPUT 3 5 6 INPUT 4 INPUT 4 6 7 DIGITAL OUTPUT 1 (-100mA) 8 DIGITAL OUTPUT 2 (-100mA) (-100mA) DIGITAL OUTPUT 2 9 1k E.O.L. 1k E.O.L. 1k E.O.L. Normally Open & Normally Closed Circuit Open = Alarm Circuit Short = Trouble INPUT 5 11 INPUT 6 2 & 3 - State Wiring (Circuit types 0, 1 & 2) 12 13 INPUT 7 14 INPUT 8 15 1 k ohm 1 k ohm NO NO 4 - State Wiring (Circuit types 3 & 4) 180 180 ohm ohm INPUT 5 10 INPUT 6 11 12 INPUT 7 13 INPUT 8 14 NC 16 1k E.O.L. NC 17 1k E.O.L. 1k E.O.L. 1k E.O.L. Normally Open Circuit Short = Alarm Circuit Open = Trouble 820 ohm E.O.L. Normally Closed Switch Open = Alarm Circuit Short = Trouble Circuit Open = Trouble 1k E.O.L. 17 18 Type 1 19 INPUT 10 INPUT 10 19 Type 2 20 1k E.O.L. 20 21 INPUT 11 22 INPUT 12 Common NC Common Circuit Type 0 1 2 Circuit Type 3 4 Switch Type NO or NC NC NO 25 1k E.O.L. 1k E.O.L. 820 ohm INPUT 9 23 820 ohm E.O.L. 1k E.O.L. Type 0 INPUT 9 24 180 ohm E.O.L. 1k E.O.L. NO 820 ohm NC Normally Open Switch Closed = Alarm Circuit Short = Trouble Circuit Open = Trouble 1k 1 k E.O.L. E.O.L. Enclosed Door Tamper 18 Input Circuit Type 3 180 ohm E.O.L. NC 180 ohm E.O.L. 15 NC 16 Input Circuit Type 2 820 ohm E.O.L. UL requires the door tamper to be connected to a 24 hour armed input. 9 10 180 ohm E.O.L. 7 8 (-100mA) DIGITAL OUTPUT 1 The Digital Outputs on the 1034 are open collector (switched negative) outputs. These are programmed and have the same capabilities as those on the 1032. 1k E.O.L. 1k E.O.L. 820 ohm E.O.L. INPUT 11 21 INPUT 12 22 23 NC Switch Type NC NO Circuit type is set in software 25 INPUT 13 INPUT 13 26 27 INPUT 14 INPUT 14 27 29 INPUT 15 INPUT 15 29 30 INPUT 16 INPUT 16 30 31 12VDC OUTPUT 32 NEGATIVE 28 28 1k E.O.L. 1k E.O.L. 1k E.O.L. 1k E.O.L. 12V Sounder +12 Volts Unswitched 32 LOW AC MASTER-SLAVE/ SLAVE-SLAVE COMM. RS-485 OUT T T R R X X X X + - + 45 46 47 48 RS-485 IN T T R R X X X X + - + 41 42 43 44 OUTPUT EXTENDER 37 38 39 40 The Output will pull low at 1/3 of the Door Hold Open Time. Automatically shuts off when Door is closed. T31 T8 MOV LOW BATTERY 12VDC FUSE 180 ohm E.O.L. Note /// All unused Inputs must be terminated with a 1k ohm EOL Resistor. 31 12VDC OUTPUT NEGATIVE BATTERY FUSE 820 ohm E.O.L. Type 4 24 26 1 AMP TOTAL 180 ohm E.O.L. Type 3 12V Relay HIGH AC PC-MASTER COMM. M O D E RS-232 M RS-485 T R N P T T R R X X E W X X X X G R + - + 49 50 51 52 53 54 55 56 N E G A T I V E 57 B A T T E R Y + 58 + 12V - GND E A R T H G N D 59 All coil driven devices require a MOV across power input. 16.5 VAC 60 61 NC Primary AC Power Source 110 VAC Transformer Providing 16.5 VAC 40VA Modem Requires: Power, Data, Phone Line RS-232 Communications 1036 Output Extender Side A Output 3 Output 3 NC C NO Side B NC C NO Output 4 Output 4 NC C NO NC C NO T32 Panel to Panel RS-485 Communications Master to Slave RS-485"IN" to RS-485"IN" TX to RX RX to TX Slave to Slave 1036 37 38 39 40 12V GND GND - RS-232 Connectors at Modems T31 RS-485"OUT" to RS-485"IN" TX to TX RX to RX Polarity Always + to + and - to - Modem DB25 1030 Controller Pin 2 Pin 3 Pin 7 Pin 4,5,8 Pin 6,20 Terminal 49 Terminal 50 Terminal 51 Together Together 9VDC Modem 18AWG 25 feet max. +DB25 to Modem For UL Applications the AC Power "ON" LED must be wired in parrallel with the 16.5VAC 40VA primary power transformer Data Earth Ground (Cold Water Pipe) Phone Line or RS-232 Direct Connect PC DB9 PC DB25 1030 Controller Pin 2 Pin 3 Pin 5 Pin 3 Pin 2 Pin 7 Term 49 Term 50 Term 51 Enclosed AC Power "ON" LED + Data DB25 to PC To Modem at PC 12V / 7AH Battery DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 888-419-8353 Phone 214-553-6140 Phone 214-553-6147 Fax www.dsxinc.com Win1034b.p65