Current Transducer HMS 5..20-P IPN = 5 .. 20 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Provisional All Data are given with a R L = 10 kΩ Electrical data Primary nominal current rms IPN (A) Primary current measuring range IPM (A) Primary Conductor Size x Turns (mm) ± 15 ± 30 ± 45 ± 60 0.8 x 2 x 4T 0.8 x 2 x 4T 1.2 x 2.2 x 2T 1.2 x 2.2 x 2T 5 10 15 20 VOUT VREF RL ROUT CL VC IC Output voltage (Analog) @ IP IP = 0 Reference voltage 1) - Output voltage VREF Output impedance VREF Load impedance Load resistance Output internal resistance Capacitive loading Supply voltage (± 5 %) Current consumption @ VC = 5 V Type HMS HMS HMS HMS Features 05-P 10-P 15-P 20-P VREF ± (0.625·IP/IPN) V VREF ± 0.025 V 2.5 ± 0.025 V typ. 200 Ω ≥ 200 kΩ ≥2 kΩ < 10 Ω <1 µF 5 V 22 mA Accuracy - Dynamic performance data X ε L TCVOUT TCVREF TCVOUT /VREF TCG VOM t ra tr di/dt Vno BW Accuracy 2) @ IPN , TA = 25°C Linearity error 0 .. IPN .. 3 x IPN Temperature coefficient of VOUT @ IP = 0 Temperature coefficient of VREF Temperature coefficient of VOUT / VREF @ IP = 0 Temperature coefficient of G Magnetic offset voltage @ IP = 0, after an overload of 3 x IPN DC Reaction time @ 10 % of IPN Response time to 90 % of IPN step di/dt accurately followed Output voltage noise (DC .. 10kHz) (DC .. 1MHz) Frequency bandwidth (-3 dB) ≤± ≤± ≤± ≤± ≤± ≤± 1 0.5 1 0.4 0.01 0.2 % of IPN % of IPN % of IPN mV/K %/K mV/K ≤ ± 0.07% of reading/K < ± 1.2 <3 <5 > 50 < 20 < 40 DC .. 50 % of IPN µs µs A/µs mVpp mVpp kHz Ambient operating temperature Ambient storage temperature Mass Standard according to UL94-V0. Special feature • For SMT mounting Advantages • Small size and space saving • Only one design for wide current ratings range • High immunity to external interference. • Internal & external reference Applications • AC variable speed drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) (SMPS) - 40 .. + 85 °C - 40 .. + 85 °C app. 6 g EN 50178 (97-10-01) Notes : 1) It is possible to overdrive VREF with an external reference voltage between 2 - 2.8 V providing its ability to sink or source approximately 2.5 mA. 2) Excluding offset and hysteresis. 070511/2 and secondary circuit • Isolation test voltage 4300V • Low power consumption • Extremely low profile, 12mm • Single power supply +5V • Fixed offset & gain • Isolated plastic case recognized • Switched Mode Power Supplies General data TA TS m • Hall effect measuring principle • Galvanic isolation between primary • Power supplies for welding applications. Application domain • Industrial LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/4 www.lem.com Current Transducer HMS 5..20-P Isolation characteristics Vb Vb Vd dCp dCl CTI Rated isolation voltage rms with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Rated isolation voltage rms with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Rms voltage for AC isolation test, 50 Hz, 1 min Creepage distance Clearance distance Comparative tracking index (Group I ) 300 V 600 V 4.3 > 8.0 > 8.0 > 600 kV mm mm Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/4 070511/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HMS 5..20-P (in mm. 1 mm = 0.0394 inch) 16 max. 12 max. 13.5 max. 3.5 10 +/-1.0 A 3.2 +/-0.5 +/-0.4 2 3 4 +/-0.3 1 5.8 P=1.27 6 B 4-0.5*0.25 0.3 S 0.2 S S 5 Operation Principle Recommended connection circuit HMS 05-P 5V (1) 0V (2) Vout Output (3) Vref.(IN/OUT) 0V V Ref. IN/OUT (4) +Vc 47nF 4.7nF 47nF HMS 05-P HMS 10-P HMS 15-P HMS 20-P A B TURNS 0.8 t 2.0 w 4t • General tolerance 1.2 t 2.2 w 2t • Solder reflow patterns Mechanical characteristics (unless otherwise stated) ± 0.2 mm Remarks • VOUT is positive when IP flows from terminal 5 (IN) to terminal 6 (OUT). • Temperature of the primary conductors should not exceed 100°C. The parts and P.C.B. surface temperature P b-free reflow profile Pe ak 25 0deg (5 s ec m ax. ) (*) 245 +/- 5deg 2 to 5 deg /s ec 6 0 + /-15sec 180 +/-3 0s ec. 4 to 8 d eg/s e c 150deg 180d eg 2 t o 5 deg/ sec Tim e (*) preliminary. will be 260 deg (5 sec max.) in final version. Page 3/4 070511/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer HMS 5..20-P Method of custody Followings are the basic regulations for storage of the transducers. Please take into account the below conditions when you store the Pb free transducers. (1) Store in a place where the temperature and humidity are steady, avoiding direct sunlight. (Temperature: 5 .. 35 degree / Humidity: 40 .. 75 %RH) (2) Remove from corrosive gas environment such as sulfidizing gas or chlorine gas. (3) Container must be prevented from static charge. (4) Remove from grit and dust. (5) Prevent from excessive loading. (6) After the long-term storage, check soldering performance and oxidation / rust in terminal area before using. For long-term storage, keep the package vacuumized, or use dry silica gel and tightly cover the container. (7) Take care not to generate surface condensation, which is created by rapid temperature change. Page4/4 070511/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com