Current Transducer HXN 03 .. 50-P 1 2 3 4 IPN = 3 .. 50 A 5 For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 6 其余: 6.3 A A 19 6 4 0.5 3 5 6 15 2 3-P=3-2.54 1 19 A B B B 3.5 Electrical data 0.5 20 1.25 15 B 4.9 3-P=2.54 0.5 A C C 0.25 d 10.85 GENERAL LINEAR TOL : 0.5 2.9 20 Features Primary nominal Primary current, Primary conductor Type current rms measuring range diameter x turns ●● Galvanic isolation between IPN (A) IPM (A) (mm) Solidworks primary and secondary circuit HXN 03-P 3 ± 9 0.6 d x 20 T ● ● Hall effect measuring principle single wire outline drawing HXN 05-P 5 ± 15 0.8 d x 12 T ● ● Isolation voltage 3000 V HXN HXN 10-P 10 ± 30 1.1 d x 6 T 50.33.00.025.0 00 ● ● Low power consumption HXN 15-P 15 ± 45 1.4 d x 4 T ●● Extended measuring range EXECUTION HXN 20-P 20 ± 60 1.6 d x 3 T Solidworks (3 x I ) PN HXN 25-P 25 ± 75 1.6 d x 2 T outline drawing with supply busbar from ± 12 to ± 15 V ●● Power HXN 50-P 50 ± 150 1.2 x 6.3 x 1 T HXN ●● Isolation plastic case recognized 50.33.00.027.0 VOUT Output voltage (Analog) @ ± IPN, RL = 10 KΩ, TA = 25°C ± 4 V according to UL 94-V0. RL Load resistance ≥ 10 KΩ ROUT Output internal resistance < 50 Ω Advantages VC Supply voltage (± 5 %) 1) ± 15 V ●● Low insertion losses IC Current consumption < ± 15 mA ●● Easy to mount with automatic handling system Accuracy - Dynamic performance data ●● Small size and space saving ●● Only one design for wide current X Accuracy @ IPN , TA = 25°C (excluding offset) < ± 1 % of IPN ratings range εL Linearity error (0 .. ± IPN) < ± 1 % of IPN ●● High immunity to external VOE Electrical offset voltage @ TA = 25°C < ± 40 mV interference. V Hysteresis offset voltage @ I = 0, 3.5 GENERAL ANGULAR TOL: UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN MILLIMETERS. <CS>KEY CHARACTERISTICS <C> CAPABILITY DIMENSIONS 0.25<+> FUNCTIONAL DIMENSIONS 1.2 C 2.9 D Title: 8.9 THIS DOCUMENT IS THE PROPERTY OF LEM. NO COPY NO TRANSMISSION WHITOUT OUTORISATION. Available for DATE TYPE EXECUTION 5.4 SIZE SCALE A4 Created 09.09.18 YNS Checked 1 09.09.18 YYJ Approved 09.09.18 ZYJ DRAWING-NUMBER 1 GENERAL LINEAR TOL : 2 GENERAL ANGULAR TOL: UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN MILLIMETERS. Title: D REVISION THIS DOCUMENT IS THE PROPERTY OF LEM. NO COPY NO TRANSMISSION WHITOUT OUTORISATION. Available for <CS>KEY CHARACTERISTICS <C> CAPABILITY DIMENSIONS <+> FUNCTIONAL DIMENSIONS DATE TYPE SIZE SCALE A4 Created 09.09.18 YNS Checked 1 09.09.18 YYJ Approved 09.09.18 ZYJ Cheaked 2 DRAWING-NUMBER 1 OH P after an excursion of 1 x IPN TCVOE Temperature coefficient of VOE TCVOUT Temperature coefficient of VOUT (% of reading) tr Response time to 90 % of IPN step BW Frequency bandwidth (- 3 dB) 2) Ambient operating temperature Ambient storage temperature Mass Standards REVISION 2 ≤ 15 < ± 1.5 ± 0.1 ≤ 3 50 mV mV/K %/K µs kHz General data TA TS m C Cheaked 2 - 25 .. + 85 °C - 25 .. + 85 °C 8 g EN 50178: 1997 Applications ●● ●● ●● ●● AC variable speed drives DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) ●● Switched Mode Power Supplies (SMPS) ●● Electrical appliances. Application domain ●● Industrial. Notes:1)Also operate at ± 12 V power supplies, measuring range reduced to ± 2.5 x IPN 2) Small signal only to avoid excessive heating of the magnetic cores. Page 1/3 100603/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com 00 Current Transducer HXN 03 .. 50-P Isolation characteristics Vd Vw Ve dCp dCI CTI Rms voltage for AC isolation test, 50 Hz, 1 min Impulse withstand voltage 1.2/50 µs Partial discharge extinction voltage rms @ 10 pC Creepage distance Clearance distance Comparative Tracking Index (group I) > 3 ≥ 6 ≥ 1 Min 5.5 5.5 600 kV kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Rated isolation voltage Nominal voltage Basic insulation 600 V 600 V Reinforced insulation 300 V 150 V dCp, dCI, Vw Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 100603/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HXN 03 .. 50-P (in mm.) 1 2 3 4 1 5 2 HXN 03 .. 25-P 6 3 4 其余: HXN 50-P 6.3 19 1: 2: 3: 4: 5: 6: B 2.9 10.85 GENERAL ANGULAR TOL: Mechanical characteristics Title: ●● General tolerance ± 0.5 mm D 1 <CS>KEY CHARACTERISTICS <C> CAPABILITY DIMENSIONS <+> FUNCTIONAL DIMENSIONS 2 1 1.4 0.8 1.1 25-P 50-P d 1.6 1.6 1.2 X 6.3 5.4 Secondary pins dimension 0.5 x 0.25 UNLESS OTHERWISE GENERAL LINEAR TOL : 15-P 0.6 1.2 8.9 10-P 20-P 0.5 0.25 d 05-P d 3.5 0.5 C 03-P HXN 20 20 3.5 2.9 0.5 Primary conductor diameter HXN 0.25 - 15 V 0V + 15 V Output Primary input Current (+) Primary input Current (-) 1.25 0.5 Terminal Pin Identification 15 4.9 3-P=2.54 6 15 3-P=3-2.54 19 A SPECIFIED,DIMENSIONS ARE IN MILLIMETERS. Available for THIS DOCUMENT IS THE PROPERTY OF LEM. NO COPY NO TRANSMISSION UNLESS OTHERWISE WHITOUT OUTORISATION. GENERAL LINEAR TOL : SPECIFIED,DIMENSIONS GENERAL ANGULAR TOL: DATEARE TYPE IN MILLIMETERS. Created EXECUTION <CS>KEY CHARACTERISTICS Solidworks <C> CAPABILITY DIMENSIONS <+> FUNCTIONAL DIMENSIONS SIZE Available for SCALE 09.09.18 YY Approved 09.09.18 ZY EXECUTION Title: A4 single wire outline drawing Cheaked 2 outline drawing with busbar DRAWING-NUMBER REVISION HXN 50.33.00.025.0 00 HXN 2 Page 3/3 100603/0 09.09.18 YN Checked 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com