Gas Controllers QAS-1000C DESCRIPTION Modular, wall-mounted, multi-point electronic control system. APPLICATION General purpose: monitor, detect, control and alarm toxic and combustible substance. Able to interface with any compatible DDC/PLC control or automation system. SPECIFICATIONS Power - Supply - Consumption Type of operation Output Trip/Setpoint setting - Low alarm - High alarm - Auxiliary Differential switching Operating - Manual push button - Time delay switching - Alarm stages - Auxiliary stage - Relay action - Audible alarm - Fail on indication Status LED display (operates without time delay) Analog input Adm. ambient temperature - Working - Storage Adm. ambient humidity Operating pressure Wire - Connection - Size Cable entry Housing - Material - Color - Protection - Dimension W x H x D (Module without panel) Listing/approvals 120 VAC, +10%/-15%, 50 to 60 Hz 5 VA / point module On/Off; Low Alarm - Stage I High Alarm - Stage II Auxiliary - Stage III for setpoint or fail safe guard 3 DPDT Factory calibrated, user adjustable Per customer gas application schedule Per customer gas application schedule Fail-on condition 10%, fixed Power On/Off, audio On/Off Test-activating relays, acknowledgement/reset 30 seconds to 8 hours, selectable in 30 second increments Auxiliary, 2 minutes to 8 hours, selectable in 2 minute increments Latching or non-latching, normally energized or not energized, selectable Various sequence, selectable Various sequence, selectable Power On - Green, Auxiliary - Red Fail - Red, Alarm Low - Yellow, Alarm High - Red Any QTS - sensors/transmitters, 4-20mA -22°F to 122°F (-30°C to 50°C) -40°F to 122°F (-40°C to 50°C) 0 to 99%, non-condensing Ambient, ± 10% Terminal blocks, screw type for lead wire Min. 24 AWG (0.2 mm2), max. 14 AWG (2 mm2) Multiple holes for 1/2 conduit, covered 18 gauge steel Gray NEMA 1 1.97 x 5.24 x 6.93 in (50 x 133 x 176 mm) CSA, C22.2 - No. 205 UL-recognized DPDT relays Phone (858) 578-7887 & (888) GO INTEC Fax (858) 578-4633 & (888) FX INTEC INTEC Controls, Inc., P.O. Box 12506, La Jolla, CA 92039 www.inteccontrols.com Specification subject to change without notice. Printed in USA 0001 QAS-1000C Panel Control Sensor Module Blank Total Panel Size Module * Qty ** Size Plate W x H x D in (mm) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2 2 4 4 8 8 8 8 1 -1 -3 2 1 -- Ship Weight lb (kg) 4.7 x 13.0 x 8.5 (120 x 330 x 215) 4.7 x 13.0 x 8.5 (120 x 330 x 215) 8.5 x 13.0 x 8.5 (215 x 330 x 215) 8.5 x 13.0 x 8.5 (215 x 330 x 215) 17 x 13.0 x 8.5 (430 x 330 x 215) 17 x 13.0 x 8.5 (430 x 330 x 215) 17 x 13.0 x 8.5 (430 x 330 x 215) 17 x 13.0 x 8.5 (430 x 330 x 215) 6.6 6.6 13.2 15.4 22.0 24.2 26.4 28.6 (3) (3) (6) (7) (10) (11) (12) (13) Part Number QAS-1001C QAS-1002C QAS-1003C QAS-1004C QAS-1005C QAS-1006C QAS-1007C QAS-1008C * Completely installed wall-mounted panel. ** Sensors/Transmitters not supplied with the panel. WIRING DIAGRAM QAS-1000C Ground (–) 120 VAC (+) Commissioning: Allow 24 hours warm-up time period 1 x per Panel Module NC Common NO NC Auxiliary Stage III Common NO Sensor/Transmitter (–) Common Black Signal Yellow (+) 24 VDC Red Aux. Output Battery Backup For two wire transmitters, connect (+) 24 VDC & Signal (– ) 4-20mA repeater/feedback (+) to other controllers (by special order) NC Common NO NC DPDT Contact Rating High Alarm Stage II Maximum Operating • Voltage • Voltage • Current 250 VAC 30 VDC 5A Load Resistive Inductive 5A 5A 5A 5A 5A 3.5 A 3.5 A 3.5 A 3.5 A 2.5 A Common NO NO Ventilation System Control Common NC NO Low Alarm Stage I 240 VAC 208 VAC 120 VAC 24 VAC 24 VDC Common NC Phone (858) 578-7887 & (888) GO INTEC Fax (858) 578-4633 & (888) FX INTEC INTEC Controls, Inc., P.O. Box 12506, La Jolla, CA 92039 www.inteccontrols.com Max. switching Capacity 1250 VA 150 W 875 VA 120 W Specification subject to change without notice. Printed in USA 0001