140U-D Product Overview • Protection Functions – Short circuit protection – Thermal overcurrent protection • Features – – – – – Fixed magnetic / fixed thermal trip Short circuit trip level 15...20 x In Current limiting Interrupting rating @480Y/277: up to 100kA 100% rated up to 15A • Standards – UL489 / CSA22.2 No.5 – IEC60947-2 • Footprint – 45W x 102H x 85D mm / 1.77W x 4.02H x 3.53D inch Compact current limiting UL489 circuit breaker Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 140U-D Product Overview • Product Range – 2 & 3 pole • 140U-D6D2.. & 140U-D6D3.. – 0.5...30A • 14 device ratings: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30 Amp • Accessories – Compact busbar and feeder blocks – 140M front mount accessories (aux. contacts, knobs, door handle) – Contactor connection modules 3-pole 2-pole 2 & 3 pole devices up to 30A Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 140U-D Accessories overview • Compact bus bar 64A • Terminal block 64A • Connection Modules – Eco connection module 25A – Flexible wire module 32A • Accessories from 140M line – Front mount auxiliary contacts – Lockable knobs – Door handles Series E (and later), AFC July 11 – Shunt and under voltage trip units Series B (and later), AFC Sept 11 • Load side terminal cover for UL489 compliance when front mount auxiliary contacts are installed Simplify product use in many applications Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 140U-D Circuit Breaker Handle trip position @ 45° Device Rating Marker holder for 1492-MS10X17, 1492-M6X12 or 100-FM Handle with 3 positions - ON - OFF - Trip Trip differentiation flag (differentiation between short circuit and overload trip) Test trip actuator Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 140U-D Circuit Breaker • Trip indication & differentiation – separate trip position of handle – short circuit trip indicator flag Overload trip indication • Easy fault finding – trip indicator distinguish between overload and short circuit trip – makes fault finding less time consuming – assists operators in troubleshooting and minimizing downtime Short circuit trip indication Trip differentiation – Unique feature Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 140U-D Interrupting Ratings Thermal-Magnetic, Fixed Thermal-Fixed Magnetic Rated Magnetic Breaking Capacity (50 Hz) Interrupting Rating (60 Hz) 2 Pole 3 Pole Current Trip [A] Im [kA] [kA] Cat. No. ‡ Cat. No. ‡ I n [A] 400…415V 525V 690V Icu Ics Icu Ics Icu Ics 240V 480Y/277V 600Y/347V 0.5 15...20 x In 100 65 65 65 50 50 100 100 50 140U-D6D2-A50 140U-D6D3-A50 1 15...20 x In 100 65 65 65 50 50 100 100 50 140U-D6D2-B10 140U-D6D3-B10 2 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B20 140U-D6D3-B20 3 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B30 140U-D6D3-B30 4 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B40 140U-D6D3-B40 5 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B50 140U-D6D3-B50 6 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B60 140U-D6D3-B60 8 15...20 x In 100 65 65 65 10 6 100 100 50 140U-D6D2-B80 140U-D6D3-B80 10 15...20 x In 100 65 65 65 10 6 100 100 50 140U-D6D2-C10 140U-D6D3-C10 12 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C12 140U-D6D3-C12 15 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C15 140U-D6D3-C15 20 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C20 140U-D6D3-C20 25 15...20 x In 65 50 65 25 10 6 65 65 35 140U-D6D2-C25 140U-D6D3-C25 30 15...20 x In 65 50 65 25 10 6 65 65 35 140U-D6D2-C30 140U-D6D3-C30 Up to 15A suitable for continuous operation at 100% of rating only if used in a cubicle space of 250 x 175 x 150 mm (10 x 7 x 6 inch) ‡ Current Limiting - data see specification or www.ab.com/catalogs High Interrupting Ratings Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 194R Next Gen 30/60A Benefits Key Benefits 1. Safety: Removable fuse carriers – for J, CC, DIN, BS88 and NFC fuses Fuse carriers interlock with switch when switch is ON IP20 finger-safe terminals Blown fuse indication in fuse carriers (optional) Internal handle for compliance with NFPA 79 requirements (optional) 194R New Product Announcement Bulletin 194R Fused & Non-Fused Disconnects (100 through 1250A) 194R-NU100-1753 Product extension to our family of disconnect switches, molded case circuit breakers, motor protection circuit breakers and motor circuit protectors 194R-D160-1753 Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 33 Fused Disconnect - Construction Construction: • Modular Construction • Each phase is capsulated (electrically isolated) • Minimizing possible phase to phase short • Clearance & Creepage distances per UL98 • 200 kA Short Circuit rating for UL Disconnects • 200kA Short Circuit rating for 100A IEC Disconnect • 100kA Short Circuit rating for 200, 400, 600 & 800A IEC Disconnects (Confidential – For Internal Use Only) Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 854J & 854K Tower Lights Overview • 854J (40 mm) and 854K (60 mm) – Modular construction design – Offered as separate components or as Preconfigured arrangements from factory – Spring Clamp Terminal blocks on the bases. – “Tool-free” lens assembly that ease installation time. – Ingress Protection cULus Type 4/4x/13, IP66 in all bases, Light and sound modules • Suitable for Indoor/ Outdoor use – Wide variety of mounting options and accessories The modular design of the 854J and 854K allows easy, tool free assembly and customization in the field or plant floor (Confidential – For Internal Use Only) Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 35 854J & 854K -Bases • Versatile offering of mounting options: – – – – – – – – Vertical mounting base Pole Mount Bases (10 and 25 cm length) Threaded Tube bases (10 and 25 cm length) Quick release Base (10 and 25 cm. length) ½ in. NPT Base Surface Mount Base- Flange Style Surface Mount w/ preinstalled screws Double Sided Base • Can accommodate up to10 modules in one single arrangement ½” NPT Base Surface Mount –Flange Style Base Vertical Mount Base Note: All Bases will be supplied with cap. Double Sided Base Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 36 854J & 854K -Light Modules • Available in 24V DC, 120V AC and 240V AC • Light Modules functionality (for both 854J & 854K): – – – – Steady Incandescent Steady LED Flashing LED LED Strobe • Exclusive for the 854K: – Multi flash LED (available in 24VDC only) • Six Colors available for every function – Red, Green, Amber, Blue, Clear, Yellow – LED color matches Lens Color – Color coded nameplate to identify module’s operating voltage • There is no restriction on having different illumination technologies in the same tower Light. • Incandescent Light modules are field assembled and requires to purchase Lens and bulb separately Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 37 854J & 854K -Sound Modules • Single Circuit Sounder – Piezoelectric technology – Selectable Continuous/Pulsing via DIP Switch – Estimated output level @ 1 m: • 80dB(A) for the 854J • 90 dB(A) for the 854K - Volume adjustable – Preserves the IP66 rating when installed on the stack. 854J Sounder • Always mounted on top Continuous/Pulsing DIP Switch 854K Sounder Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 38 854J & 854K -Accessories • 4 Watts Incandescent bulbs – Sold in packs of 5 pieces per box – Incandescent solution for the 854J and 854K Tower Lights • 10 cm plastic base extension – Works with Surface, ½ in NPT or Vertical Mount bases – Adds 10 cm height to the Tower Light assembly and preserves IP 66 rating • Double Sided Mount base – Allows to have up to (10) modules in one single stack arrangement – It could be used for vertical or horizontal mounting Double Sided base 10 cm base extension Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 39 854J & 854K Preconfigured versions • Pre-configured versions available for 24V AC/DC and 120V AC • Bases available as configured option – ½” NPT, Vertical mount, Surface Flange style, Pole Mount (10&25 cm) and Quick Release Base (10 & 25 cm length) • Light Module options: – Steady LED, Flashing LED and Strobe LED • Sounders – Piezoelectric Single circuit Ideal for applications that require always the same stack configuration Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 40 Bulletin 855H Recordable Horn Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Overview • Logical migration on applications that require an additional level of audible annunciation beyond the traditional sounder tones • The new 855H-R will allow customers to download or record in the same unit: – Voice – Melodies – Customized tones provided by the user • Displays clear messages to avoid confusion or to provide specific advice in the actions to take when an alarm is present. • Preserves the same “Look and Feel” of our High Performance Horns Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Frame Sizes Frame C (DC Version) Frame E (AC & DC Versions) Frame C (AC Version) Flare Style Version Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Product Overview • Three sizes available to cover most of the applications: – Frame C • dB Output : 101db(A) @ 1m Voice, 110dB(A) @ 1 m Tone – Frame E and Flare Style: • dB Output : 111db(A) @ 1m Voice, 126dB(A) @ 1 m Tone • Extended Voltage Operating range for all frames – – – – 10…30V DC (Frame C Horn) 12….30V DC (Frame C combo) 14…30 V DC (Frame E and Flare Style Horns and frame E combo) 90…260V AC (AC version for all Frames) • cULus Type 4/4X/13/3R, IP 66 Ingress protection rating. • Available as stand-alone Horn or Combination Unit (Horn and Beacon) – Continuous/ Flashing LED Beacon (DIP Switch Selectable) – 2Hz Flashing frequency – LED Colors available: Green, Red and Amber The highest dB(A) output level for Messages in the Industry! Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Recording Features • Two ways to record a message in the unit: – Via the On-Board Microphone (ideal for single Installations) – Via the 3.5 mm Audio Input (allows recording from analog sources) • Total of 2 minutes of recording capacity – Split in 4 channels (stages) of 30 sec. max per channel – The Horn will edit time to match recorded content • Exceptional CD Quality recording – 32KHz recording sample rate- CD Quality – 16KHz playback sample rate that produces exceptional clarity – Depends on the original quality of recorded content • Line Level Peak indicator – Indicates that output volume has been set at the optimum level at the source device – Ensures maximum SPL (Sound Pressure Level) at message play-back • “Message only” or “Message and Tone” Playback selectable No additional Hardware needed to record a message! Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Additional Features • Separate Volume control for Tone and recorded content – Enables independent output levels for Tones and Messages • Up to 4 remote selectable stages – Selected by standard “Negative switching” on DC Units • 45 Tones to select via Dip Switches – Optimized selection for better tone contrast between stages Stage 1 selected via DIP switch Automatically pre-set when Stage 1 is selected via DIP switch Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H- Recordable Horn Stage Remote Selection • “Negative Switching” to enable the (4) Stages: DC Units AC Units Stages Control for DC Units Message 1 will be played when (+) and (-) are present Message 2 will be played when (+) and (-) are present and S2 is closed Message 3 will be played when (+) and (-) are present and S3 is closed Message 4 will be played when (+) and (-) are present and S4 is closed Copyright © 2010 Rockwell Automation, Inc. All rights reserved. 855H Recordable Horn Additional Features • “Play-through” capability – Listen the content as it is being recorded – Available when downloading is made from an analog source • Master-Slave Functionality – The message is recorded only in the Master unit. – Replicate content to other devices using a single cable – If the recording is missed in the master unit the messages can be retrieved from a slave unit. • Synchronized output in multi-horn installations – Similar to the High Performance Horns by Daisy chain the (+) and ( -) Terminals in the Horns. – Jumper in the Synch mode • No need to perform message format conversion – No proprietary Software required – No third-party freeware/shareware required. Functionality that saves Installation and Commissioning time Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Thank You !! November 7-8, 2012 100+ Vendors 16 Hands-On Labs, 63 Technical Sessions (Each Day) Schaedler Yesco will be offering transportation and lodging packages Details coming Summer 2012