IEC Contactors & Starters XT IEC Power Control 34-49 February 2007 Contactors and Starters Accessories Auxiliary Contacts Notes: The 7 – 32A XTCE Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules. Front mounted snap-on auxiliary contacts for XT contactors are available with screw or spring cage terminals in a variety of contact configurations. The 40 – 65A XTCE Contactors have positively driven contacts within the auxiliary contact module. 6 auxiliary contacts are possible with a combination of side mounted and front mount auxiliary contacts. Frame B – C contactors with 1NC built-in auxiliary are mirror contacts (XTCE...B01_ – XTCE...C01_). Table 34-75. XTCE and XTCS Auxiliary Contact Overview Frame A B C D F G L–R Catalog Numbers Contactor Width Built-In Auxiliary Contact Sequence XTMC6A... – XTMC9A... 45 mm 1NO or 1NC XTCE007B... – XTCE015B... 45 mm 1NO or 1NC XTCE018C... – XTCE032C... 45 mm 1NO or 1NC XTCE040D00_ – XTCE065D00_ 55 mm — XTCE080F00_ – XTCE095F00_ 90 mm — XTCE115G00_ – XTCE150G00_ 90 mm — XTCE185L22_ – XTCEC20R22_ Various 2NO-2NC A1 1 3 5 13 Front (Top) Mount Auxiliary A1 1 3 5 A1 1 3 5 13 21 31 43 A2 2 4 6 2-Pole (Screw Only): A2 2 4 6 14 22 32 44 A1 1 3 5 21 A2 2 4 6 14 A2 2 4 6 22 2-Pole & 4-Pole Standard 2-Pole & 4-Pole Ver(Screw or Spring Cage): sions (Screw or Spring Cage): N/A 4-Pole (Screw or Spring Cage): Tall Version (Screw Only): Side Mount Auxiliary N/A N/A 2-Pole (Screw Only): 2-Pole (Screw or Spring Cage): Frame L – R auxiliary contacts also apply to XTCS185L… – XTCS500M… contactors. CA08102001E For more information visit: www.eaton.com For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 34 IEC Contactors & Starters XT IEC Power Control 34-50 February 2007 Contactors and Starters Table 34-76. Auxiliary Contacts Conventional Thermal Current, Open at 60°C Ith = Ie, AC-1 in Amps Poles Contact Configuration 16 2 2NO 16 2 1NO-1NC 16 2 2NC 16 2 1NOE-1NCL 16 2 1NO-1NC Circuit Symbol Pkg. Qty. Screw Terminals Catalog Number Spring Cage Terminals Catalog Number 5 XTCEXFAC20 XTCEXFACC20 5 XTCEXFAC11 XTCEXFACC11 5 XTCEXFAC02 XTCEXFACC02 5 XTCEXFALC11 XTCEXFALCC11 5 XTCEXFDC11 XTCEXFDCC11 5 XTCEXFCC02 XTCEXFCCC02 5 XTCEXFAC40 XTCEXFACC40 5 XTCEXFAC31 XTCEXFACC31 5 XTCEXFAC22 XTCEXFACC22 5 XTCEXFAC13 XTCEXFACC13 5 XTCEXFAC04 XTCEXFACC04 5 XTCEXFCLC22 XTCEXFCLCC22 5 XTCEXFCC22 XTCEXFCCC22 Price U.S. $ Frame B – C — Front (Top) Mount 34 53 63 54 64 53 61 54 62 51 61 52 62 57 65 58 66 21 33 22 34 21 31 16 2 2NC 16 4 4NO 16 4 3NO-1NC 16 4 2NO-2NC 16 4 1NO-3NC 16 4 4NC 16 4 1NOE-1NCL 16 4 2NO-2NC 21 31 22 32 53 6373 83 54 6474 84 53 61 73 83 54 62 74 84 5361 71 83 54 62 72 84 536171 81 54 62 72 82 51 61 71 81 52 62 72 82 5765 71 83 58 66 72 84 21 31 43 53 22 32 44 54 Orders must be placed in multiples of package quantity listed. 1 early-make contact (1NOE), 1 late-break contact (1NCL). To avoid duplicate terminal numbers in contact sequence, these auxiliary contacts should only be used with contactors having a built-in 1NO contact (XTCE...B10_, XTCE...C10_). Technical Data . . . . . . . . . . . . . . . . . . Page 34-75 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 IEC Contactors & Starters XT IEC Power Control 34-51 February 2007 Contactors and Starters Table 34-76. Auxiliary Contacts (Continued) Conventional Thermal Current, Open at 60°C Ith = Ie, AC-1 in Amps Poles Contact Configuration 2 2NO Circuit Symbol Pkg. Qty. Screw Terminals Catalog Number Spring Cage Terminals Catalog Number 5 XTCEXFATC20 — 5 XTCEXFATC11 — 5 XTCEXFATC02 — 5 XTCEXFATC22 — 1 XTCEXSCC11 — 5 XTCEXFBG20 — 5 XTCEXFAG11 — 5 XTCEXFBG11 — 5 XTCEXFBG02 — 5 XTCEXFBG40 XTCEXFBGC40 5 XTCEXFBG31 XTCEXFBGC31 5 XTCEXFBG22 XTCEXFBGC22 5 XTCEXFAG22 XTCEXFAGC22 5 XTCEXFBG13 XTCEXFBGC13 5 XTCEXFBG04 XTCEXFBGC04 5 XTCEXFBLG22 XTCEXFBLGC22 Price U.S. $ Frame B – C — Front (Top) Mount — Tall Version 16 53 63 54 64 16 2 1NO-1NC 16 2 2NC 16 4 2NO-2NC 53 61 54 62 51 61 52 62 5361 71 83 54 62 72 84 Frame C — Side Mount 10 2 1NO-1NC 53 61 54 62 Frame D – G 16 2 2NO 13 23 16 2 1NO-1NC 53 61 16 2 1NO-1NC 54 62 13 21 16 2 2NC 16 4 4NO-0NC 13 23 33 43 16 4 3NO-1NC 13 21 33 43 16 4 2NO-2NC 13 21 31 43 16 4 2NO-2NC 53 61 71 83 16 4 1NO-3NC 13 21 31 41 16 4 0NO-4NC 11 2131 41 16 4 1NOE-1NCL 13 21 35 47 14 24 14 22 11 21 12 22 14 24 34 44 14 22 34 44 14 22 32 44 54 62 72 84 14 2232 42 12 2232 42 Orders must be placed in multiples of package quantity listed. 1 early-make contact (1NOE), 1 late-break contact (1NCL). Front (Top) Mount Tall Version is for use with Frame B Electrical Wire Bridges and Link Kits (see Pages 34-56, 34-57) and Toolless Plug Combination Connection Kits: XTCEXRLB, XTCEXSDLB, XTPAXTPCB, XTPAXTPCRB, XTPAX. CA08102001E 14 22 36 48 Can be mounted to the left side of contactor only. Cannot be used in combination with front (top) mount auxiliary contacts or mechanical interlocks. Notes: ■ Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not NC (late break) contact). ■ No auxiliary contacts can be fitted between two contactors. ■ Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO (early make) and NC (late break) contacts) and for the built-in auxiliary contacts of the XTCE007B... – XTCE032C.... Technical Data . . . . . . . . . . . . . . . . . . Page 34-75 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 34 IEC Contactors & Starters XT IEC Power Control 34-52 February 2007 Contactors and Starters Table 34-77. Side Mount Auxiliary Contacts for Frame D – R, 40 – 2000A Conventional Free Air Poles Thermal Current, Ith = Ie, AC-1 in Amps Contact Configuration 10 2 1NO-1NC 10 2 1NOE-1NCL Circuit Symbol Pkg. Qty. Screw Terminals Catalog Number Spring Cage Terminals Catalog Number 1 XTCEXSBN11 XTCEXSBNC11 1 XTCEXSBLN11 — 1 XTCEXSCN11 XTCEXSCNC11 Price U.S. $ Frame D – R 17 84 61 83 62 71 26 72 54 47 53 25 35 1NO-1NC 48 2 22 36 10 43 18 31 44 14 32 34 21 13 1 early-make contact (1NOE), 1 late-break contact (1NCL). To maintain proper terminal marking, XTCEXSCN_ should not be used with Frame D contactors and only used with Frame F – G contactors in combination with XTCEXSBN_. Table 34-78. Auxiliary Contacts Possible Combinations Frame Size Catalog Number Contactor Built-In Auxiliary Front (Top) Mount 2-Pole 1 — 4-Pole — 1 A XTMC6A… – XTMC9A… 1NO or 1NC B XTCE007B… – XTCE015B… C XTCE018C… – XTCE032C… Side Mount 2-Pole — — — 1NO or 1NC 1 — 1NO or 1NC Total Auxiliary Contacts Available 3 5 — — 1 — — — 3 5 — 1 — — 1 — — 3 5 — — 1 3 — D XTCE040D00_ – XTCE065D00_ — 1 — — 1 2 1 6 6 — F–G XTCE080F00_ – XTCE150G00_ — 1 — — — 1 — 2 2 4 6 8 8 — L–R XTCE185L22_ – XTCEC20R22_ 2NO-2NC — — — — 2 8 — Notes: ■ Forced operation contact to IEC/EN 60947-5-1 Appendix L (positively driven), inside the auxiliary contact unit (not early close and late opening). ■ Auxiliary normally closed contact can be used as mirror contact to IEC/EN 60947-4-1 Appendix F (not late opening). ■ No auxiliary contacts can be fitted between two contactors. Technical Data . . . . . . . . . . . . . . . . . . Page 34-75 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 IEC Contactors & Starters XT IEC Power Control 34-53 February 2007 Contactors and Starters XTMC6A... – XTMC9A... XTCE007B... – XTCE032C... XTMCXF...A... XTCEXF...C... 2-Pole or 4-Pole 34 Frame A – B XTCEXF...C... 2-Pole or 4-Pole XTCEXSCC11 XTCE007B... – XTCE032C... or XTCE018C... – XTCE032C... + Frame C or XTCEXF...G... 4-Pole + + XTCEXSBN11 + XTCEXSBN11 XTCEXF...G... 2-Pole XTCEXSBN11 + XTCE040D... – XTCE065D... XTCEXSBN11 XTCEXSBN11 XTCE040D... – XTCE065D... + Frame D or + + XTCE080F... – XTCE150G... + XTCE185L... – XTCEC20R... + + XTCEXSCN11 + XTCEXSBN11 (Built-In) + XTCEXSBN11 (Built-In) XTCEXSCN11 Frame F – G Frame L – R Figure 34-37. Auxiliary Contact Combinations CA08102001E For more information visit: www.eaton.com For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 XTCEXSCN11 + XTCEXSBN11 XTCEXF...G... 2-Pole or 4-Pole XTCEXSCN11 + XTCEXSBN11 XTCEXSBN11 XTCE080F... – XTCE150G... IEC Contactors & Starters XT IEC Power Control 34-54 February 2007 Contactors and Starters Varistor Suppressor with Integrated LED Suppressors The switching of contactor coils can generate voltage transients that may cause arching on switch contacts and/or damage electronics on the control line. Either a RC or Varistor Suppressor is recommended in these types of applications. All XT DC contactor coils have built-in suppression. 34 Varistor Suppressors clamp the voltage transient above the maximum coil voltage and are recommended when the level of the transient is known to not exceed the coil voltage. RC Suppressors slow and reduce the level of the voltage transient but do not clamp them at a specific level. The slowing of the transient can reduce electrical interference. These are recommended in applications where operating rates are high. RC Suppressor A1 A2 Table 34-81. Varistor Suppressor Voltage AC For Use with… 24 – 48 130 – 240 XTCE007B – XTCE015B 10 10 XTCEXVSLBW XTCEXVSLBB 24 – 48 130 – 240 XTCE018C – XTCE032C 10 10 XTCEXVSLCW XTCEXVSLCB 24 – 48 130 – 240 XTCE040D – XTCE095F 10 10 XTCEXVSLFW XTCEXVSLFB A1 Contact Sequence A2 Voltage For Use with… 24 – 48 48 – 130 110 – 240 240 – 500 24 – 48 110 – 130 130 – 240 240 – 500 24 – 48 110 – 130 130 – 240 240 – 500 XTCE007B – XTCE015B, 10 XTCF020B 10 10 10 XTCE018C – XTCE032C 10 10 10 10 XTCE040D – XTCE095F 10 10 10 10 Pkg. Qty. Catalog Number Price U.S. $ Note drop-out delay. For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. Orders must be placed in multiples of package quantity listed. Free-Wheel Diode Suppressor Table 34-79. RC Suppressor Contact Sequence Pkg. Qty. Catalog Number Price U.S. $ A1 Contact Sequence XTCEXRSBW XTCEXRSBA XTCEXRSBB XTCEXRSBC XTCEXRSCW XTCEXRSCA XTCEXRSCB XTCEXRSCC XTCEXRSFW XTCEXRSFA XTCEXRSFB XTCEXRSFC A2 Table 34-82. Free-Wheel Diode Suppressor Voltage DC For Use with… 12 – 250 XTCE007B – XTCE015B, 10 XTCF020B Note drop-out delay. For AC operated contactors, 50 – 60 Hz. DC operated contactors and XTCE165G_ and XTCE150G_ have a built-in suppressor circuit. Orders must be placed in multiples of package quantity listed. Varistor Suppressor Pkg. Qty. Catalog Number Price U.S. $ XTCEXDSB In addition to the built-in suppressor circuit for DC actuated contactors. Prevents negative breaking voltage when contactors are used in combination with a safety PLC. Orders must be placed in multiples of package quantity listed. Voltage Indicator A1 Contact Sequence A1 Contact Sequence A2 A2 Table 34-83. Voltage Indicator Table 34-80. Varistor Suppressor Voltage For Use with… 24 – 48 48 – 130 130 – 240 240 – 500 24 – 48 48 – 130 130 – 240 240 – 500 24 – 48 48 – 130 130 – 240 240 – 500 XTCE007B – XTCE015B, 10 XTCF020B 10 10 10 XTCE018C – XTCE032C 10 10 10 10 XTCE040D – XTCE095F 10 10 10 10 Pkg. Qty. Catalog Number Price U.S. $ XTCEXVSBW XTCEXVSBA XTCEXVSBB XTCEXVSBC XTCEXVSCW XTCEXVSCA XTCEXVSCB XTCEXVSCC XTCEXVSFW XTCEXVSFA XTCEXVSFB XTCEXVSFC Voltage DC For Use with… Pkg. Qty. Catalog Number 12 – 48 48 – 130 110 – 250 XTCE007B – XTCE015B, XTCF020B 10 10 10 XTCEXVIBW XTCEXVIBA XTCEXVIBB 24 – 48 48 – 130 130 – 250 XTCE018C – XTCE032C 10 10 10 XTCEXVICW XTCEXVICA XTCEXVICB 42 – 48 48 – 130 130 – 250 DC operated: XTCE040D – XTCE095F AC/DC operated: XTCE115G – XTCE150G 10 10 10 XTCEXVIGW XTCEXVIGA XTCEXVIGB Price U.S. $ Orders must be placed in multiples of package quantity listed. Note drop-out delay. For AC operated contactors, 50/60 Hz. DC operated contactors have a built-in suppressor. Orders must be placed in multiples of package quantity listed. For more information visit: www.eaton.com Technical Data . . . . . . . . . . . . . . . . . . . Page 34-75 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 IEC Contactors & Starters XT IEC Power Control 34-55 February 2007 Contactors and Starters Electronic Timer Modules Table 34-84. Electronic Timer Modules for Frame B – C Contactors (7 – 32A) Voltage Contact Sequence Timing Range For Use with… Pkg. Qty. Catalog Number 0.05 s – 1 s 0.5 – 10 s 5 s – 100 s XTCE...B... XTCE...C... 1 XTCEXTEEC11T XTCEXTEEC11A XTCEXTEEC11B 0.05 s – 1 s XTCE...B... XTCE...C... 1 0.5 – 10 s XTCE...B... XTCE...C... 1 5 s – 100 s XTCE...B... XTCE...C... 1 1 s – 30 s XTCE...B... XTCE...C... 1 XTCEXTEYC20T XTCEXTEYC20A XTCEXTEYC20B XTCEXTEE, XTCEXTED, XTCEXTEY 1 XTCEXTESHRD Price U.S. $ On-Delayed 24V AC/DC A1 100 – 130V AC 200 – 240V AC A2 57 65 58 66 Off-Delayed 24V AC/DC 100 – 130V AC 200 – 230V AC 24V AC/DC 57 65 A1 A2 58 66 57 65 A1 100 – 130V AC 200 – 240V AC 24V AC/DC 100 – 130V AC 200 – 240V AC A2 58 66 57 65 A1 A2 58 66 XTCEXTED1C11T XTCEXTED1C11A XTCEXTED1C11B XTCEXTED10C11T XTCEXTED10C11A XTCEXTED10C11B XTCEXTED100C11T XTCEXTED100C11A XTCEXTED100C11B Star-Delta 24V AC/DC 100 – 130V AC 200 – 240V AC 57 67 A1 A2 58 68 Sealable Shroud — Transparent sealable shroud used to protect electronic timer modules from unwanted access. Front (Top) mounted timer modules for use with XTCE...B and XTCE…C contactors. Can not be combined with top mount auxiliary contacts, XTCEXF...C__. Table 34-85. XTCR Reversing Contactor Components Qty Frame B C D F G 2 2 1 1 XTCE...B01_ XTCEXFAC20 XTCEXMLB XTCEXRLB XTCE...B01_ XTCEXFAC20 XTCEXMLC XTCEXRLC XTCE...D00_ XTCEXFBG11 XTCEXMLD XTCEXRLD XTCE...F00_ XTCEXFBG11 XTCEXMLG XTCEXRLG XTCE...G00_ XTCEXFBG11 XTCEXMLG XTCEXRLG Contactor Auxiliary Contact Mechanical Interlock Reversing Link Kit Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 34 IEC Contactors & Starters XT IEC Power Control 34-56 February 2007 Contactors and Starters Mechanical Interlock Star-Delta (Wye-Delta) Link Kits Table 34-86. Mechanical Interlock Main current wiring for star-delta (wye-delta) combinations. Includes Paralleling Bridge, Reversing Bridge, and Star-Delta Bridge. Does not include Mechanical Interlock, see Table 34-86. 34 For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B, XTCF020B 5 XTCEXMLB XTCE018C – XTCE032C XTCE040D – XTCE065D XTAE080F – XTCE150G 1 1 1 XTCE185L – XTCE500M XTCE580N – XTCEC10N Price U.S. $ Table 34-88. Star-Delta (Wye-Delta) Link Kits XTCEXMLC XTCEXMLD XTCEXMLG 1 For Use with… Pkg. Qty. Catalog Number Price U.S. $ XTCE007B – XTCE015B 1 XTCEXSDLB XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE080F – XTCE095F 1 1 1 XTCEXSDLC XTCEXSDLD XTCEXSDLF XTCE115G – XTCE150G XTCE185L – XTCE225L XTCE250L XTCE300M – XTCE400M 1 1 1 1 XTCEXSDLG XTCEXSDLL225 XTCEXSDLL250 XTCEXSDLM400 XTCEXMLM XTCEXMLN 1 Also includes Interlocking Bridge (XTCEXLBB). The following control cables are integrated for electrical interlock: K1M: A1 – K2M: 21; K1M: 21 – K2M: A1; K1M: A2 – K2M: A2. Paralleling Bridge For two contactors with AC or DC operated magnet system which are horizontally or vertically mounted. For B – G frames, mechanical lifespan is 2.5 x 106 operations and the distance between contactors is 0 mm. For L – N frames, mechanical lifespan is 5 x 106 operations and no auxiliary contact can be mounted between the mechanical interlock and the contactor — the distance between contactors is 15 mm. Orders must be placed in multiples of package quantity listed. XTCEXMLG and XTCEXMLN consist of an interlock element and mounting plate. Component part of Reversing Link Kit (XTCEXRL_). Parallels the phases on the line-side of two contactors. Table 34-89. Paralleling Bridge Reversing Link Kits Main current wiring for reversing combinations. Includes Paralleling Bridge and Reversing Bridge. Does not include Mechanical Interlock, see Table 34-86. For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B 20 XTCEXPBB XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE080F – XTCE150G 20 10 10 XTCEXPBC XTCEXPBD XTCEXPBG Price U.S. $ Orders must be placed in multiples of package quantity listed. Reversing Bridge Table 34-87. Reversing Link Kits For Use with… XTCE007B – XTCE015B Pkg. Qty. 1 Catalog Number Price U.S. $ XTCEXRLB Component part of Reversing Link Kit (XTCEXRL_). Reverses the phases on the load-side of two contactors. Table 34-90. Reversing Bridge XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE115G – XTCE150G 1 1 1 XTCEXRLC XTCEXRLD XTCEXRLG XTCE185L – XTCE250L 1 XTCEXRLL XTCE300M – XTCE400M 1 XTCEXRLM400 Also includes Interlocking Bridge (XTCEXLBB). The following control cables are integrated for electrical interlock: K1M: A1 – K2M: 21; K1M: 21 – K2M: A1; K1M: A2 – K2M: A2. For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B 20 XTCEXRBB XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE080F – XTCE150G 20 10 10 XTCEXRBC XTCEXRBD XTCEXRBG Price U.S. $ Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 IEC Contactors & Starters XT IEC Power Control 34-57 February 2007 Contactors and Starters Electrical Interlocking Bridge Add-On Fourth Pole Connects NC auxiliary contact with A2 terminal of other contactor in reversing application. Included in XTCEXRLB reversing link kit. Table 34-91. Electrical Interlocking Bridge For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B 20 XTCEXLBB Price U.S. $ Add-On Fourth Pole for use with Frame D contactors. Only for AC-1 load. Up to two auxiliary contacts can be fitted. Table 34-94. Fourth Pole Orders must be placed in multiples of package quantity listed. Star-Delta (Wye-Delta) Bridge Component part of Star-Delta Link Kit (XTCEXSDL_). Commons the 3-phases on the line side of shorting contactor. For Use with… AC-1 (A) Open/ Enclosed Pkg. Qty. Catalog Number XTCE040D00_ XTCE050D00_ XTCE065D00_ 35/30A 75/60A 1 1 XTCEX4P35D XTCEX4P75D Price U.S. $ Parallel Link Table 34-92. Star-Delta (Wye-Delta) Bridge For Use with… Pkg. Qty. Catalog Number Price U.S. $ XTCE007B – XTCE015B XTCE018C – XTCE032C 20 20 XTCEXSDBB XTCEXSDBC XTCE040D – XTCE065D XTCE080F – XTCE150G XTCE185L – XTCE400M XTCE500M 10 1 1 1 XTCEXSDBD XTCEXSDBG XTCEXSDB400 XTCEXSDB500 For using one contactor per phase. Each package comes with (2) links for line: load. Table 34-95. Parallel Link Orders must be placed in multiples of package quantity listed. Frame B is tool-less connection type. For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B 5 XTCEXPLKB XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE080F – XTCE150G XTCE185L 5 XTCEXPLKC 1 XTCEXPLKD 1 XTCEXPLKG 1 XTCEXPLKL185 Price U.S. $ Connector Table 34-93. Connector For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE032C 50 XTCEXCNC Price U.S. $ XTCE040D – XTCE150G 10 XTCEXCNG Fourth Pole can be broken off: 4-Pole: Ith = 60A; 3-Pole: Ith = 50A. AC-1 current carrying capacity of the contactor increases by a factor of 2.5. For XTCEXPLKL185, one shroud is included for protection against accidental contact. Protected against accidental contact in accordance with IEC 536. Orders must be placed in multiples of package quantity listed. For mechanically arranging contactors in combinations. Distance between contactors is 0 mm. Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616 34 IEC Contactors & Starters XT IEC Power Control 34-58 February 2007 Contactors and Starters 3-Phase Commoning Link Terminal Flat Bar Main current wiring that parallels and commons the line side of multiple contactors. For use with Frame B contactors only. Protected against accidental contact, short-circuit proof. Max voltage (Ue) = 690V, Max Current (Ie) = 63A. For connection of a flat strip conductor. Comes with control circuit terminal (consisting of 3 flat strip conductor terminals). Table 34-100. Terminal Flat Bar For Use with… Table 34-96. 3-Phase Commoning Link 34 Notes Pkg. Qty. Suitable for 3 5 contactors, length = 135 mm Suitable for 4 5 contactors, length = 180 mm Suitable for 5 5 contactors, length = 225 mm Catalog Number Price U.S. $ Pkg. Qty. XTCE500M – 1 XTCE650N XTCE750N – 1 XTCE820N XTCEXCLK3B Catalog Number Price U.S. $ XTCEXTFB650 XTCEXTFB820 Note: Not UL Listed. XTCEXCLK4B Control Wire Terminal Extension XTCEXCLK5B Orders must be placed in multiples of package quantity listed. Incoming Terminal Terminal for use with three-phase commoning link XTCEXCLK_B. Fits to Frame F – G contactors and allows connection of control wire to power terminals. Table 34-97. Incoming Terminal Table 34-101. Control Wire Terminal Extension For Use with… Pkg. Qty. Catalog Number XTCE007B – XTCE015B 5 XTCEXITB Price U.S. $ For Use with… Pkg. Qty. Catalog Number XTCE080F – XTCE150G 10 XTCEXTCWG Price U.S. $ Orders must be placed in multiples of package quantity listed. Terminal Shrouds Orders must be placed in multiples of package quantity listed. Protection against direct contact with connection lugs when touched vertically from the front. Terminal Lug Assembly For connection of: round conductor, flexible and stranded, flat strip conductor. With control circuit terminal. See Table 34-118, Page 34-75 for terminal capacities. Table 34-102. Terminal Shrouds Table 34-98. Terminal Lug Assembly For Use with… Pkg. Qty. Catalog Number Price U.S. $ XTCE185L – XTCE225L XTCE250L – XTCE400M 1 XTCEXTLA225 1 XTCEXTLA400 For Use with… Pkg. Qty. Catalog Number Price U.S. $ XTCE185L – XTCE400M XTCE500M XTCE580N – XTCE650N XTCE750N – XTCEC10N 1 XTCEXTS400 1 1 XTCEXTS500 XTCEXTS650 1 XTCEXTS820 Terminal Lug Kit — Set of (3) Lugs Table 34-99. Set of (3) Lugs For Use with… Description Pkg. Catalog Qty. Number XTCE500M Set of 3 Lugs #4-500MCM 2-Phase Cu/Al 500A Set of 3 Lugs #2-500MCM 2-Phase Cu/Al 650A Set of 3 Lugs #2-500MCM 4-Phase Cu/Al 820A 1 XTCEXTL500 1 XTCEXTL650 1 XTCEXTL820 XTCE650N XTCE820N Price U.S. $ Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616