www.encelium.com Wireless Control Module ENCELIUM Wireless and ENCELIUM GreenBus II® Communication Networks ENCELIUM® Energy Management System – Hardware Key Features & Benefits —— Control module for all of the following: —— Connects 0-10V dimmable luminaires to network for: – 0-10V dimmable luminaires –Customizing lighting scenes for – DALI ballasts tailored experiences/tasks – Occupancy sensors –Adjusting light levels to respond —— ENCELIUM GreenBus II® connection to variable lighting requirements available for GreenBus II devices ENCELIUM Wireless Energy Management System Architecture WM SIM WCM OSRAM offers a special Damp-Rated (DR) WCM for installations subject to moderate degrees of moisture. The WCM is compatible to ENCELIUM hardwired products via the GreenBus II port on the device. This enhances the flexibility of the system to include phase-cut dimming, area lighting control and relay panel control. C UL US LMS103R1 7-15 er & Pow g Line itch le w to s ALC g min Dim FLOOR 2 Light Fixture WCM GreenBus II® ® Tenant Ethernet Polaris 3D /PCS/PCW Network er Pow Line Wireless Sensor EN-RPM-24C-GB2 Relay Panel Module +50ºC Item No 45268 Max ambient temperature Input: Only40V 24V AC, 50/60Hz, AClass 2 min Energy Management Equipment Subassembly Emergency Lighting and Power Equipment 6NA8 Made in Canada 2012 2013 2014 Q1 QQ 2 2015 Q 3 and 4 installation Install per instruction sheet electrical & building codes. to ENCELIUM GreenBusII . Connect only CAUTION To Reduce - System theOf Risk of Fire or Electric Shock Do Not Interconnect The Outputs Dif ferent Class 2 Circuits Relay Panel WCM PCDM ut se C tures ix Pha AC ming F Dim Wireless Wall Station PoE Switch ENCELIUM Ethernet Network The WCM switches a fixture ON or OFF via a relay contained in the module as well as delivers a low voltage dimming signal to any 0-10V dimming ballast/driver. A WCM can be connected to LED drivers without isolation between the dimming section and the electrical output for added flexibility in LED driver options. Low-Voltage Sensor Router FLOOR 1 The Wireless Control Module (WCM) is a key component of the ENCELIUM Energy Management System (EMS). This device allows luminaires and occupancy sensors to communicate via a mesh network based on ZigBee® standards. Individually addressable, the WCM enables each ballast or LED driver to be independently controlled and configured to best meet the needs of the facility. Light Fixture 85-1 16-DA WCM WM Polaris 3D® SSU System Architecture This illustration shows how each component is easily integrated into the ENCELIUM Wireless Energy Management System (EMS). The ENCELIUM Wireless system communicates via a mesh network based on ZigBee standards. The WCM is powered by incoming line voltage. Each WCM, sensor, and wallstation uses a wireless mesh network to relay data back to the Wireless Manager (WM). WMs typically control individual floors and are linked via an Ethernet Network back to the SSU. Internet or LAN connection allow floor plan based control software via Polaris 3D ® to be operated anywhere on the network. For reference, the component shown on this data sheet is highlighted. Ordering Information Item Number 45572 45583 Ordering Description EN-WCM-ZB-DR EN-WCM-ZB Communication Network ZigBee® Wireless ZigBee Wireless Modifiers - Damp-Rated -DR Specifications —— 3.17" x 1.64" x 1.27" (80.42mm x 41.6mm x 32.31mm) —— Operating temperature range: -40°C (-40°F) to 60°C (140°F) —— Suitable for luminaire or junction box mounting in standard 1/2" knockout (7/8" dia.) —— Absolute Maximum Ratings 300W (all rated voltages have a tolerance of +/-10%): – 4.5A 120-347 Vac Ballast/LED Driver – 5.8A 120-347 Vac Tungsten – 9.0A 120-347 Vac General Purpose —— Single 0-10V dimming output (IEC 60929 Annex E). Capable of sinking 10mA (this is equivalent to 10 typical dimming ballasts/drivers) —— Standard units are for indoor use only or for mounting inside waterproof enclosure —— Damp-rated units may be used in damp locations —— Radio Properties - 2.4 GHz —— Wireless Range: 100' line of sight, 50' through standard walls when WCM is mounted exterior to the luminaire – Range decreases by 50% when mounted inside the luminaire —— Safety approvals: – Energy Management Equipment (UL 916) – Emergency Lighting Equipment (UL 924 cULus Listed) – Heat and Smoke Release for Air-Handling Spaces (UL 2043) —— 0-10V or DALI connectivity —— ENCELIUM GreenBus II connection port for GreenBus II devices —— Complies with the following electromagnetic requirements: – EN 61000-4-2 – EN 61000-4-4 – EN 61000-4-5 —— FCC Part 15/ICES-003 1.64” (41.60mm) 0.96” (24.31mm) 1.23” (31.31mm) 1.27” (32.31mm) Dimensions 3.17” (80.42mm) Installation Diagram The mechanical construction allows for simple installation of the WCM to an available 1/2 inch knock-out on the side or on top of a fixture (as shown below). All necessary wiring for the electronic dimming ballast or LED driver is available on the inside. Fixture Mounting For some installations, a junction box may be required. It is recommended to securely mount the WCM to the junction box (as shown below) using an available 1/2 inch knock-out and a retainer nut. J Box Mounting M WCM WC re u Fixt Wiring Diagrams Wiring to Luminaire Wiring to Low Voltage Sensor LINE BLACK NEUTRAL RED VIOLET GREY BLUE VIOLET/ + GREY/ BLUE NEUTRAL Power Feed NEUTRAL LINE Power Feed BLACK NEUTRAL RED VIOLET GREY BLUE 0-10V ELECTRONIC BALLAST/DRIVER NOT USED VIOLET/ + GREY/ BLUE NOT USED POWER COMMON SIGNAL Wiring Using GreenBus II Port Only Power Feed LINE INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE WCM INPUT RED BLUE INPUT RED BLUE TM OUTPUT OUTPUT 3 GreenBusII . Connect to Energy Management System only. OUTPUT OUTPUT 2 Power fail input INPUT RED BLUE 3 1 Power supply input 24V AC, 60Hz, 1.6A (40VA) Class 2 only OUTPUT INPUT RED BLUE 2 2 4 6 8 10 12 14 16 18 20 22 24 Relays OUTPUT OUTPUT INPUT RED BLUE OUTPUT OUTPUT INPUT RED BLUE OUTPUT OUTPUT INPUT RED BLUE INPUT RED BLUE OUTPUT OUTPUT 4 1 1 3 5 7 9 11 13 15 17 19 21 23 Relays INPUT RED BLUE INPUT RED BLUE OUTPUT OUTPUT or OUTPUT or INPUT RED BLUE PCDM ALC NEUTRAL Relay Panel blue red 2013 Q2 2014 Q3 2015 Q4 INPUT RED BLUE Energy Management Equipment Subassembly Emergency Lighting and Power Equipment INPUT RED BLUE Q1 INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE INPUT RED BLUE 2012 OUTPUT OUTPUT 6NA8 Made in Canada OUTPUT OUTPUT Item No 45268 OUTPUT OUTPUT EN-RPM-24C-GB2 Relay Panel Module Max ambient temperature +50ºC Input: Class 2 Only 24V AC, 50/60Hz, min 40VA Install per installation instruction sheet and electrical & building codes. Connect to ENCELIUM GreenBusII System only. CAUTION - To Reduce the Risk of Fire or Electric Shock Do Not Interconnect The Outputs Of Different Class 2 Circuits 85-116-DA OUTPUT Depress with tool to unlock LED Always On -> 24V and GreenBusII TM Present LED Single Blink -> Only GreenBusII TM Present LED Double Blink -> Only 24 VAC Present OUTPUT black blue red GE Relays INPUT RED BLUE 4 Manual Toggle Button WR Relays BLACK NEUTRAL RED VIOLET GREY BLUE VIOLET/ + GREY/ BLUE NOT USED NOT USED NOT USED Wire Table Wire Color BLACK RED WHITE VIOLET GREY BLUE Wiring to Luminaire Line In - Relay Contact Line Out - Relay Contact Neutral Class 2, Low Voltage, 0-10Vdc, 10mA max. Class 2, Low Voltage Return/Common Not Used Note: GreenBus II port can also be used when wiring to a luminaire. Americas Headquarters OSRAM SYLVANIA Inc. 100 Endicott Street Danvers, MA 01923 USA Phone1-888-531-7571 www.encelium.com OSRAM is a registered trademark of OSRAM GmbH. ENCELIUM, GreenBus II and Polaris 3D are registered trademarks. ZigBee is a registered trademark of ZigBee Alliance. Specifications subject to change without notice. © 2015 OSRAM Wiring to Low Voltage Sensor Line In - Relay Contact Not Used Neutral (WCM Input Only) Power Common Signal Wiring Using GreenBus II Port Only Line In Not Used Neutral Not Used Not Used Not Used Wire Length 9.84" (250mm) 9.84" (250mm) 9.84" (250mm) 23.62" (600mm) 23.62" (600mm) 7.09" (180mm)