SUBMITTAL DATA

advertisement
 SUBMITTAL DATA
DATE:
PROJECT:
CUSTOMER:
APRIL 7, 2014
PASCO WWTP AHU and CONDENSING UNIT REPLACEMENT
APOLLO SHEET METAL
The units listed below and detailed in the attached literature is being supplied for the PASCO WWTP project. Qty ( 1 ) OAH012 Air Handling Unit /
ACZ013B Condensing Unit
One approved copy of this submittal must be returned before units are released into production.
Vemco Inland Northwest, Inc. 3830 E. Trent Spokane, WA 99202 Phone (509)534‐9533 • Fax (509)534‐9524 SUBMITTAL DATA for Pasco WWTP Sold to APOLLO SHEET METAL 1207 W. COLUMBIA DR Kennewick, WA 99336 Phone: 509‐586‐1104 Job Number: DDBYD5 Customer PO#: 23060‐0001 Job Number: Job Name: DDBYD5 Pasco WWTP Page 1 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Table of Contents Technical Data Sheet for AHU‐1001 SKYLINE ........................................................................................................................... 3 Fan Curve for AHU‐1001 SKYLINE ............................................................................................................................................ 7 Drawing for AHU‐1001 SKYLINE ............................................................................................................................................. 10 Certified Drawings, AC Scroll Condensing Unit, ACZ... ............................................................................................................ 12 Job Number: Job Name: DDBYD5 Pasco WWTP Page 2 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Job Information Technical Data Sheet Job Name Date Submitted By Software Version Unit Tag Unit Overview Pasco WWTP April 07 2014 JAS 10.13 AHU‐1001 SKYLINE Supply
Model Number Air Volume
cfm OAH012GDAM Static Pressure
External
Total
inWc inWc
2.00 3.62
4000 Height
in
48*
External Dimensions
Width in 56* Length
in
170
*Not including base rails, coil connectors, drain connectors, vestibule sections, control boxes and hoods.
Unit Model Number: Approval: Outer Panel: Liner: Insulation: Unit Configuration: Base: Roof Curb Kit: Parts Warranty: Mixing Box Portion OAH012GDAM
ETL Listed / ETL Listed to Canadian Safety Standards (ETL Label / ETLc Label)
Painted standard G60 Galvanized Steel
Galvanized Steel (unless noted per section)
R‐13 Injected Foam
Drive (Handling) Location: Right Inline horizontal
Wall Thickness: 2 in Curb ready Altitude: 450 ft 0 in Standard One Year
Component: 1 Length: 46 in Damper Size (length x width) Overall Opening Location
Outside Air 42 in x 38 in 38 in x 28 in Right Return Air 34 in x 36 in 30 in x 26 in End Shipping Section: 1 Rated CFM
Air Pressure Drop Quantity
Hoods
4000 cfm 0.04 insWg 1 Fitted 4000 cfm 1 Type
UltraSeal Low Leak UltraSeal Low Leak Door
Technical Data Sheet for AHU‐1001 SKYLINE Technical Data Sheet for AHU‐1001 SKYLINE Location Width
Opening
Non‐drive side 30 in
Outward
Panel Filter Type Throwaway Clean Air 0.12 inWc Component: 2 Efficiency MERV 7 Air Pressure Drop Mean Air 0.56 inWc Length: 12 in Shipping Section: 1 Face Velocity
Face Area
Air Volume Filter Loading
316 ft/min
12.7 ft²
4000 cfm Side
Number of Filters
Height
Width Depth
4
20 in
24 in 2 in
Dirty Air
1.00 inWc
Door
Location Width
Opening
Drive side 8 in
Outward
Job Number: Job Name: DDBYD5 Pasco WWTP Page 3 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Component: 3 Internal Face and Bypass Face Air Pressure Drop 0.03 inWc Length: 12 in Shipping Section: 1 Bypass Air Pressure Drop
Opening Location
Type
0.16 inWc
Internal
Opposed blade ‐ low leak
Note: Cabinet height for bypass extended 0.00 inches above ‘External cabinet height’ referenced above.
Combination Coil Component: 4 Length: 26 in Shipping Section: 1 Direct Expansion Coil
Coil Model Total Capacity 5EJ0806C 143796 Btu/hr Air Volume Sensible Capacity Number of Coils
130200 Btu/hr 1
Entering Dry Bulb Wet Bulb Leaving
Dry Bulb
Wet Bulb
87.0 °F 56.7 °F
66.0 °F Fluid 54.0 °F
Suction Temp. Refrigerant Sub‐Cooled Refrigerant
Liquid Temp. 45.0 °F R407c 110.0 °F
Type Liquid OD Sweat 2‐0.88 in Fins per Inch Tube Diameter
Tube Spacing
(Face x Row)
8
0.625 in
1.50 in x 1.299 in
6
Air Temperature 4000 cfm Number of Rows
Coil Air Pressure Drop Finned Height 0.86 inWc
30 in
Finned Length Face Area
Face Velocity 43 in 8.96 ft²
447 ft/min
Suction Vapor Superheat Temp. at Coil Outlet
Design Saturated Condensing Temp. Piping Vestibule
8.0 °F
110.0 °F ‐ in
Connection
Quantity Suction Size
Min. Fin Surface Temp. Location
Material Drive side
Copper tube Min. Tube Wall Surface Temp. 2 2‐1.63 in
Material Fin Tube Header
Case
Aluminum .0075 in Copper .020 in Copper Galv. steel 32.0 °F
32.0 °F
Drain Pan Drain Side
Microbial resistant coated galvanized Opp drive side Component performance shown is based on the component air volume shown.
Static pressure shown is based on the component air volume shown.
AHRI 410 Certification
Coil is NOT certified by AHRI
Reheat Hot Water Coil
Coil Model Total Capacity
Number of Coils
Number of Rows
Fins per Inch
Tube Diameter
Tube Spacing
(Face x Row)
1 1
11
0.625 in 1.50 in x 1.299 in
5WH1101B 130265 Btu/hr Air Volume Air Temperature Entering Leaving Dry Bulb Dry Bulb 4000 cfm 65.0 °F Water Entering Leaving 180.0 °F 161.4 °F Type Threaded Technical Data Sheet for AHU‐1001 SKYLINE Quantity 2 Coil Air Pressure Drop Finned Height
Finned Length Face Area
Face Velocity
95.3 °F 0.10 inWc
30 in
40 in
8.33 ft²
480 ft/min
Flow Rate Pressure Drop
Velocity
Volume Weight
Piping Vestibule
14.00 gpm Connection Size 1.50 in 0.60 ftHd
1.50 ft/s
2.0 gal
22.00 lb
‐ in
Material
Min. Tube Wall Surface Temp. Fouling Factor
Location
Min. Fin Surface Temp. Drive side
Carbon steel
161.4 °F 161.4 °F
0.000
Material
Fin Aluminum .0075 in Tube
Header
Case
Copper .020 in
Copper
Galvanized track
Component performance shown is based on the component air volume shown.
Static pressure shown is based on the component air volume shown.
AHRI 410 Certification
Certified in accordance with the AHRI Forced‐Circulation Air‐Cooling and Air‐Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org Job Number: Job Name: DDBYD5 Pasco WWTP Page 4 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Technical Data Sheet for AHU‐1001 SKYLINE Component: 5 Supply Fan Length: 40 in Shipping Section: 1 Fan Performance
Air Volume 4000 cfm External Static Pressure Total Cabinet
2.00 inWc 3.62 inWc 0.00 inWc
Speed Brake Horsepower
4.25 BHP
Outlet Velocity
Operating Maximum
1653 rpm 2091 rpm
2721 ft/min
Fan Data
Fan Type Blade Type / Class Centrifugal DWDI Forward Curved / 2 Quantity of Fans
Wheel Diameter
Number of Blades
1 12.62 in
N/A
Discharge Top horizontal
Motor Location
To Side of Fan
Motor Data
Power Electrical Supply Speed Efficiency
Enclosure
Frame Size
Supplier
Number of Poles Lock Rotor Current
Full Load Current
5.0 HP 460/60/3 V/Hz/Phase 1750 rpm Premium
ODP
184 T frame
Generic
4 47.1 A
6.6 A
Fan Options
Seismic Restraint: Isolator Type: With snubbers Spring Drive Package Data*
Fan Sheave Motor Sheave Belt
Number of Belts
Actual Drive S.F. Bearing Type
AK61H AK59H A37
1
1.14 Standard ‐ L50 (200K)
*Daikin Applied reserves the right to provide a different but equivalent drive package
Door
Location Width
Opening
Drive side 30 in
Outward
Access Section Component: 6 Length: 34 in Shipping Section: 2 Air Pressure Drop
0.02 inWc
Door
Location Drive side Unit Sound Power (dB) Type 63 Hz Radiated: 76 Unit Discharge: 84 Unit Return: 81 Width
Opening
30 in
Outward
125 Hz 250 Hz
500 Hz
1000 Hz
2000 Hz 4000 Hz
8000 Hz
81 89 86 72
84
80
64
81
76
66
86
80
59 82 76 42
77
69
40
76
74
Job Number: Job Name: DDBYD5 Pasco WWTP Page 5 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Technical Data Sheet for AHU‐1001 SKYLINE Shipping Section Details Section Length in 1 136 2 34 Entire Unit 170 Weight lb P1 Corner Weights (lb)
P2
P3
2269 332 544 83 486
83
2601 688 623
P4
XX Center of Gravity (in)
YY
ZZ
585
83
655
83
74 17 26
28
26
27
613
677
84 27
26
NOTE: Special components aren't included in the corner weights and center of gravity data.
AHRI Certification Supply fan performance is certified in accordance with the Central Station Air‐Handling Unit Certification Program, which is based on AHRI Standard 430. Notes Standard
1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1 ‐ 2007. The approving authority is responsible for compliance of multi‐component building systems. Job Number: Job Name: DDBYD5 Pasco WWTP Page 6 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Fan Curve for AHU‐1001 SKYLINE Fan Curve for AHU‐1001 SKYLINE Daikin AHU Fan Curve
6.0
00
18
0r
pm
5.0
16
00
4.5
4.0
14
3.5
rp
m
00
3.0
120
2.5
1.5
0 rp
0 rp
m
30
2.0 1
00
rpm
m
800 r
25 bhp
20 bhp
18 bhp
15 bhp
10 bhp
7.5 bhp
5 bhp
3 bhp
2 bhp
0.0
10.0
8.0
6.0
2.0
hp
1.5 b
4.0
p
1 bh
pm
600 rpm
0.5 400 rpm
1.0
0.0
STATIC PRESSURE (IN. OF WATER)
220
2000 rpm
m
rp
5.5
CFM (IN 1,000's)
12.62" Forward Curved Supply Fan at Standard Conditions
Air volume
4000
cfm
Fan speed
1653
rpm
Total static
3.68
insWg
Max speed
2091
rpm
Brake horsepower
4.3
bhp
Efficiency
53.5
%
Unit tagging
AHU-1001 SKYLINE
Date
April-07-2014
Job name
Pasco WWTP
Time
14:03
Supply fan performance is certified in accordance with the Central Station
Air-Handling Unit Certification Program, which is based on AHRI Standard 430.
Job Number: Job Name: DDBYD5 Pasco WWTP Page 7 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Drawing for AHU‐1001 SKYLINE DDBYD5 Pasco WWTP Page 8 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Drawing for AHU‐1001 SKYLINE Job Number: Job Name: DDBYD5 Pasco WWTP Page 9 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Drawing for AHU‐1001 SKYLINE Job Number: Job Name: DDBYD5 Pasco WWTP Page 10 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Drawing for AHU‐1001 SKYLINE Job Number: Job Name: 00 ACZ025‐039BS Air‐Cooled Condensing Unit
Unit Dimensions ACZ010‐020BS NOTE:
ACCESS
PANEL
%%c
.875
POWER ENTRY
KNOCKOUT
(OTHER SIDE)
5.17
HOT GAS
BYPASS
SUCTION
1.
L2 & L4 ARE LOCATED ON
OPPOSITE SIDE OF UNIT.
2.
ALL WEIGHTS ARE IN POUNDS.
CONTROL BOX
ACCESS DOORS
%%c
.875
CONTROL
ELECTRICAL
KNOCKOUT
POWER
ENTRY
51.00
18.84
ACCESS
DOOR
24.57
Y
20.79
9.19
L3, L4
L1, L2
LIQUID
4.56
Z
5.06
31.15
MOUNTING
HOLES
8.86
21.18
X
7.64
46.42
46.18
49.06
4.00
MOUNTING HOLES
DIA. 1.00 INCH
QTY. 4
73.80
R331987201
CERTIFIED, 2 FAN, ACZ Dimensions and Weights CENTER OF GRAVITY (IN.) X Y Z ACZ SIZE SHIP WT. (LBS) OPN. WT. (LBS) L1 LIFTING WEIGHTS (LBS) L2 L3 L4 CONNECTION SIZES (IN. O.D.) HOT GAS SUCTION LIQUID 010‐013B 016B 27.50 26.50 21.70 21.60 22.90 23.40 1000 1065 1015 1090 369 421 379 416 124 115 128 113 1.125 1.625 0.875 0.875 0.625 0.625 020B 26.60 21.80 23.30 1150 1190 454 449 124 123 1.625 0.875 0.625 Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Certified Drawings, AC Scroll Condensing Unit, ACZ... Mounting Weights ACZ SIZE M1 MOUNTING CORNER WEIGHTS (LBS.) M2 M3 M4 010‐013B 016B 257 290 264 286 236 246 243 243 020B 312 309 266 263 Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 1 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 11 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
ACZ025‐039BS NOTE:
DIM. A = ACZ025-028 = 24.6"
ACZ033-039 = 33.0"
DIM. B = ACZ025-028 = 40.2"
ACZ033-039 = 48.7"
ACCESS
PANEL
1.
L2 & L4 ARE LOCATED ON
OPPOSITE SIDE OF UNIT.
2.
ALL WEIGHTS ARE IN POUNDS.
DIM. C = ACZ025-033 = 18.8"
ACZ039 = 12.6"
DIM. D = ACZ025-033 = 4.5"
ACZ039 = 7.5"
5.17
HOT GAS BYPASS
.875
POWER ENTRY
KNOCKOUT
(OTHER SIDE)
CONTROL PANEL
ACCESS DOORS
.875
CONTROL
ELECTRICAL
KNOCKOUT
D
2.67
SUCTION
POWER
ENTRY
ACZ025-028 =51
ACZ033-039 = 59
B
ACCESS
DOOR
A
20.79
9.19
L3,L4
Y
C
Z
L1,L2
LIQUID
5.06
8.86
31.10
MOUNTING
HOLES
21.18
7.64
46.38
X
49.06
49.06
84.95
R331987301 CERTIFIED, 3 FAN, ACZ-B
106.23
Dimensions and Weights CENTER OF GRAVITY (IN.) X Y Z ACZ SIZE Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 SHIP WT. (LBS) OPN. WT. (LBS) L1 LIFTING WEIGHTS (LBS) L2 L3 L4 CONNECTION SIZES (IN. O.D.) HOT GAS SUCTION LIQUID 025B 028B 38.50 38.50 21.90 19.10 23.30 23.30 1370 1390 1420 1445 501 508 498 505 186 189 185 188 1.625 1.625 0.875 0.875 0.625 0.625 033B 41.00 23.00 23.30 1565 1625 540 538 244 243 1.625 0.875 0.875 039B 34.60 24.00 22.40 1975 2050 753 807 201 215 2.125 0.875 0.875 Mounting Weights ACZ SIZE M1 MOUNTING CORNER WEIGHTS (LBS.) M2 M3 M4 025B 028B 446 453 443 449 241 245 240 243 033B 488 487 296 295 039B 656 703 297 318 Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 2 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 12 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Physical Data ACZ 010‐020BS, R‐407C ACZ MODEL NUMBER 010B Number Of Refrigerant Circuits Operating Charge, Lb. (kg), See Note Cabinet Dimensions, LxWxH, In. Cabinet Dimensions, LxWxH, (mm) 016B 020B 1 1 1 1 22.0 (10.0) 22.0 (10.0) 24.0 (10.9) 31.0 (14.1) 73.6 x 46.3 x 50.8 73.6 x 46.3 x 50.8 73.6 x 46.3 x 50.8 73.6 x 46.3 x 50.8 (1869) x (1176) x (1289) (1869) x (1176) x (1289) (1869) x (1176) x (1289) (1869) x (1176) x (1289)
Unit Operating Weight, Lbs. (kg) 1015 (461) 1015 (461) 1090 (495) Unit Shipping Weight, Lbs. (kg) 1000 (454) 1000 (454) 1065 (484) 1150 (523) Add'l Weight with Copper Finned Coils, Lb. (kg) 176 (80.0) 176 (80.0) 176 (80.0) 264 (120.0) COMPRESSORS Type 013B BASIC DATA 1190 (541) Scroll Scroll Scroll Scroll Nominal Horsepower 4.0 / 4.0 6.0 / 6.0 7.5 / 7.5 9.0 / 9.0 Oil Charge Per Compressor oz. (g) 57 (1616) 60 (1701) 140 (3969) 140 (3969) 0 – 50 – 100 0 – 50 – 100 0 – 50 – 100 30.3 (2.8) 30.3 (2.8) 30.3 (2.8) CAPACITY REDUCTION STEPS ‐ PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging 0 – 50 – 100 CONDENSERS ‐ HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area,Sq. Ft. (M2) Finned Height x Finned Length, In. Finned Height x Finned Length, (mm) Fins Per Inch x Rows Deep Pumpdown Capacity lb. (kg) 30.3 (2.8) 84 x 52 84 x 52 84 x 52 84 x 52 (2134) x (1321) (2134) x (1321) (2134) x (1321) (2134) x (1321) 16 x 2 16 x 2 16 x 2 16 x 3 35.3 (16.0) 35.3 (16.0) 35.3 (16.0) 50.3 (22.8) CONDENSER FANS ‐ DIRECT DRIVE PROPELLER TYPE Number Of Fans ‐ Fan Diameter, In. (mm) 2 – 26 (660) 2 – 26 (660) 2 – 26 (660) 2 – 26 (660) Number Of Motors ‐ HP (kW) 2 – 1.0 (0.75) 2 – 1.0 (0.75) 2 – 1.0 (0.75) 2 – 1.0 (0.75) Fan And Motor RPM, 60 Hz Total Unit Airflow, CFM (l/s), 60 Hz 1140 1140 1140 1140 13950 (6584) 13950 (6584) 13950 (6584) 12000 (5664) Note: Operating charge is for the condensing unit only. Refrigerant lines and evaporator charge must be added. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 3 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 13 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 ACZ025‐039BS, R‐407C ACZ MODEL NUMBER PHYSICAL DATA 025B 033B 039B BASIC DATA Number Of Refrigerant Circuits 1 1 1 1 34.0 (15.4) 36.0 (16.3) 47.0 (21.3) 50.0 (22.7) Cabinet Dimensions, LxWxH, In. 106.2x 46.3 x 50.8 106.2x 46.3 x 50.8 106.2x 46.3 x 58.8 106.2x 46.3 x 58.8 Cabinet Dimensions, LxWxH, (mm) (2697) x (1176) x (1289) Operating Charge,, Lb. (kg), See Note (2697) x (1176) x (1289) (2697) x (1176) x (1493) (2697) x (1176) x (1493)
Unit Operating Weight, Lbs. (kg) 1470 (667) 1490 (676) 1760 (799) 1960 (890) Unit Shipping Weight, Lbs. (kg) 1580 (717) 1600 (726) 1890 (858) 2090 (949) Add'l Weight with Copper Finned Coils, Lb. (kg) 426 (194) 426 (194) 435 (197) 435 (197) COMPRESSORS Scroll Scroll Scroll Scroll Nominal Horsepower 12.0 / 12.0 13.0 / 13.0 15.0 / 15.0 20.0 / 20.0 Oil Charge Per Compressor , oz. (g) 110 (3119) 110 (3119) 110 (3119) 158 (4479) 0 – 50 – 100 0 – 50 – 100 0 – 50 – 100 49.0 (4.6) 49.0 (4.6) 58.3 (5.4) 58.3 (5.4) 84 x 84 84 x 84 100 x 84 100 x 84 (2134) x (2134) (2134) x (2134) (2545 ) x (2134) (2545 ) x (2134) 16 x 2 16 x 2 16 x 3 16 x 3 53.1 (24.0) 53.1 (24.0) 90.7 (41.1) 92.8 (42.0) Number Of Fans ‐ Fan Diameter, In. (mm) 3 – 26 (660) 3 – 26 (660) 3 – 26 (660) 3 – 26 (660) Number Of Motors ‐ HP (kW) 3 – 1.0 (0.75) 3 – 1.0 (0.75) 3 – 1.0 (0.75) 3 – 1.0 (0.75) 1140 1140 1140 1140 20925 (9877) 20925 (9877) 19800 (9346) 19800 (9346) Type 028B CAPACITY REDUCTION STEPS ‐ PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging 0 – 50 ‐ 100 CONDENSERS ‐ HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area, Sq. Ft. (M2) Finned Height x Finned Length, In. Finned Height x Finned Length, (mm) Fins Per Inch x Rows Deep Pumpdown Capacity lb. (kg) CONDENSER FANS ‐ DIRECT DRIVE PROPELLER TYPE Fan And Motor RPM, 60 Hz Total Unit Airflow, CFM (l/s), 60 Hz Note: Operating charge is for the condensing unit only. Refrigerant lines and evaporator charge must be added Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 4 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 14 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Electrical Data ACZ Unit Size 010B 013B 016B 020B 025B 028B 033B 039B Volts Minimum Circuit Ampacity (MCA) Power Supply Quantity Wire Gauge 75C Quantity Nominal Size In. (mm) Recommended Maximum 208 45 3 8 AWG 1 1.00 (25) 50 50 230 45 3 8 AWG 1 1.00 (25) 50 50 460 22 3 10 AWG 1 1.00 (25) 25 25 575 19 3 10 AWG 1 1.00 (25) 20 20 208 58 3 6 AWG 1 1.00 (25) 70 70 230 54 3 6 AWG 1 1.00 (25) 60 70 460 27 3 10 AWG 1 1.00 (25) 30 35 575 22 3 10 AWG 1 1.00 (25) 25 25 208 77 3 4 AWG 1 1.00 (25) 90 100 230 77 3 4 AWG 1 1.00 (25) 90 100 460 39 3 8 AWG 1 1.00 (25) 45 50 575 30 3 10 AWG 1 1.00 (25) 35 40 208 82 3 4 AWG 1 1.00 (25) 110 110 230 80 3 4 AWG 1 1.00 (25) 90 100 460 41 3 8 AWG 1 1.00 (25) 50 50 575 33 3 10 AWG 1 1.00 (25) 40 40 208 113 3 2 AWG 1 1.25 (32) 125 150 230 113 3 2 AWG 1 1.25 (32) 125 150 460 51 3 6 AWG 1 1.00 (25) 60 60 575 41 3 8 AWG 1 1.00 (25) 50 50 208 129 3 1 AWG 1 1.25 (32) 150 175 230 129 3 1 AWG 1 1.25 (32) 150 175 460 61 3 6 AWG 1 1.00 (25) 70 80 575 51 3 6 AWG 1 1.00 (25) 60 60 208 148 3 1/0 AWG 1 1.50 (38) 175 200 230 139 3 1/0 AWG 1 1.50 (38) 175 175 460 72 3 4 AWG 1 1.00 (25) 80 100 Field Wire Field Fuse or Breaker Size Hub (Conduit Connection)
575 58 3 6 AWG 1 1.00 (25) 80 80 208 187 3 3/0 AWG 1 2.00 (51) 250 250 230 182 3 3/0 AWG 1 2.00 (51) 250 250 460 85 3 4 AWG 1 1.00 (25) 100 110 575 73 3 4 AWG 1 1.00 (25) 100 100 NOTE: See page 8 for all Electrical Data notes. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 5 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 15 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Compressor & Condenser Fan Motor Amp Draw, R‐407C ACZ Unit Size 010B 013B 016B 020B 025B 028B 033B 039B Volts Rated Load Amps Compressors No. 1 No. 2 F.L. Amps Fan Motor (Each) No. of Fan Mtrs Locked Rotor Amps L.R.Amps Fan Motor (Each) Compressors No. 1 No. 2 Across‐The‐Line 208 14.8 14.8 5.8 2 21.4 91 91 230 14.8 14.8 5.8 2 23.7 91 91 460 7.1 7.1 2.8 2 10.7 50 50 575 5.8 5.8 2.5 2 11.0 37 37 208 20.3 20.3 5.8 2 21.4 156 156 230 18.6 18.6 5.8 2 23.7 156 156 460 9.2 9.2 2.8 2 10.7 75 75 575 7.4 7.4 2.5 2 11.0 54 54 208 28.8 28.8 5.8 2 21.4 195 195 230 28.8 28.8 5.8 2 23.7 195 195 460 14.7 14.7 2.8 2 10.7 95 95 575 10.8 10.8 2.5 2 11.0 80 80 208 31.2 31.2 5.8 2 21.4 225 225 230 30.1 30.1 5.8 2 23.7 225 225 460 15.5 15.5 2.8 2 10.7 114 114 575 12.1 12.1 2.5 2 11.0 80 80 208 42.3 42.3 5.8 3 21.4 245 245 230 42.3 42.3 5.8 3 23.7 245 245 460 18.6 18.6 2.8 3 10.7 125 125 575 14.6 14.6 2.5 3 11.0 100 100 208 49.4 49.4 5.8 3 21.4 300 300 230 49.4 49.4 5.8 3 23.7 300 300 460 23.1 23.1 2.8 3 10.7 150 150 575 19.2 19.2 2.5 3 11.0 109 109 208 57.9 57.9 5.8 3 21.4 340 340 230 53.8 53.8 5.8 3 23.7 340 340 460 28.2 28.2 2.8 3 10.7 173 173 575 22.4 22.4 2.5 3 11.0 132 132 208 75.0 75.0 5.8 3 21.4 505 505 230 73.1 73.1 5.8 3 23.7 505 505 460 34.0 34.0 2.8 3 10.7 225 225 575 28.8 28.8 2.5 3 11.0 180 180 NOTE: See page 8 for all Electrical Data notes. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 6 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 16 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Field Wiring Data, R‐407C ACZ Unit Size 010B 013B 016B 020B 025B 028B 033B 039B Volts Wiring to Standard Power Block Terminal Maximum Terminal Connector Wire Range Amps (Copper Wire Only) Wiring to Optional Disconnect Switch Disconnect Size Connector Wire Range (Copper Wire Only) Wiring to High Interrupt or HSCCR Circuit Breaker Max. Connector Wire Range Amps (Copper Wire Only) 208 175 14 AWG – 2/0 60 14 AWG – 1 AWG 70 10 AWG ‐ 1/0 230 175 14 AWG – 2/0 60 14 AWG – 1 AWG 70 10 AWG ‐ 1/0 460 175 14 AWG – 2/0 60 14 AWG – 1 AWG 35 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 30 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 60 14 AWG – 1 AWG 90 10 AWG ‐ 1/0 230 175 14 AWG – 2/0 60 14 AWG – 1 AWG 80 10 AWG ‐ 1/0 460 175 14 AWG – 2/0 60 14 AWG – 1 AWG 40 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 35 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 230 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 460 175 14 AWG – 2/0 60 14 AWG – 1 AWG 60 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 50 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 230 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 460 175 14 AWG – 2/0 60 14 AWG – 1 AWG 70 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 50 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 125 3 AWG – 3/0 175 6 AWG ‐ 350 kcmil 230 175 14 AWG – 2/0 125 3 AWG ‐ 3/0 175 6 AWG ‐ 350 kcmil 460 175 14 AWG – 2/0 60 14 AWG – 1 AWG 80 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 70 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 225 2 AWG ‐ 4/0 200 6 AWG ‐ 350 kcmil 230 175 14 AWG – 2/0 225 2 AWG ‐ 4/0 200 6 AWG ‐ 350 kcmil 460 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 100 10 AWG ‐ 1/0 575 175 14 AWG – 2/0 60 14 AWG – 1 AWG 80 10 AWG ‐ 1/0 208 175 14 AWG – 2/0 225 2 AWG ‐ 4/0 225 6 AWG ‐ 350 kcmil 230 175 14 AWG – 2/0 225 2 AWG ‐ 4/0 225 6 AWG ‐ 350 kcmil 460 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 575 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 90 10 AWG ‐ 1/0 208 335 6 AWG – 400 kcmil 225 2 AWG ‐ 4/0 N/A Note 1 230 335 6 AWG – 400 kcmil 225 2 AWG ‐ 4/0 N/A Note 1 460 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 150 6 AWG ‐ 350 kcmil 575 175 14 AWG – 2/0 100 8 AWG ‐ 1/0 125 3 AWG ‐ 3/0 NOTES: 1. High Interrupt or HSCCR Circuit Breakers are not available in these sizes. 2. See page 8 for all Electrical Data notes. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 7 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 17 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 Notes Electrical Data: 1.
Unit wire size ampacity (MCA) is equal to 125% of the largest compressor‐motor RLA plus 100% of RLA of all other loads in the circuit. 2.
The control transformer is furnished and no separate 115V power supply is required. 3.
For a separate 115V control circuit power supply, use 10 amps for all unit sizes. 4.
Recommended power lead wire sizes for 3 conductors per conduit are based on 100% conductor ampacity in accordance with NEC. Voltage drop has not been included. Therefore, it is recommended that power leads be kept short. All terminal block connections must be made with copper wire. 5.
“Recommended Fuse Sizes” are selected at approximately 175% of the largest compressor RLA, plus 100% of the RLA of all other loads in the circuit. 6.
“Maximum Fuse or breaker size” is selected at approximately 225% of the largest compressor RLA, plus 100% of all other loads in the circuit. 7.
The recommended power lead wire sizes are based on an ambient temperature of 86°F (30°C). Ampacity correction factors must be applied for other ambient temperatures. Refer to the National Electrical Code Handbook. 8.
The unit must be electrically grounded according to national and local electrical codes. Voltage Limitations: Within ± 10 percent of nameplate rating. Important: Voltage unbalance not to exceed 2% with a resultant current unbalance of 6 to 10 times the voltage unbalance per NEMA MG‐1, 1998 Standard. This is an important restriction that must be adhered to. Notes for “Compressor and Condenser Fan Amp Draw”: 1.
Compressor RLA values are for wiring sizing purposes only but may not reflect normal operating current draw at rated capacity. 2.
Fan motor FLA values are approximate fan motor amp values at rated voltage. Notes for Field Wiring Wiring must comply with all applicable codes and ordinances. Warranty is void if wiring is not in accordance with specifications. Copper wire is required for all power lead terminations at the unit. ACZ‐B and AGZ‐B units have single‐point power connection. A single field supplied fused disconnect is required or it can be supplied as a factory‐
mounted option. The control transformer is factory mounted. ACZ/AGZ‐B units are rated to 115°F (46°C) maximum operating ambient air temperature as standard. There is no high ambient option of vents or fans. 1.
Requires a single disconnect to supply electrical power to the unit. This power supply must either be fused or use a circuit breaker. 2.
All field wiring to unit power block or optional non‐fused disconnect switch must be copper. 3.
All field wire size values given in table apply to 75°C rated wire per NEC. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 8 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 18 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Field Wiring Diagram Single‐Point Connection UNIT MAIN
TERMINAL
BLOCK
DISCONNECT
(BY OTHERS)
GND LUG
3 PHASE
TO COMPRESSOR(S)
AND FAN MOTORS
POWER
SUPPLY
NOTE: ALL FIELD WIRING
TO BE INSTALLED AS NEC
CLASS 1 WIRING SYSTEM
WITH CONDUCTOR RATED
600 VOLTS
FUSED CONTROL
CIRCUIT
TRANSFORMER
120
VAC
DISCONNECT
(BY OTHERS)
TB1-20
N
TB1
10A
FUSE
120VAC
CONTROL POWER
CONTROL
CIRCUIT
FUSE
1
(BY OTHERS)
LIQUID LINE SOLENOID
120 VAC 1.0 AMP MAX
2
120 VAC
SV1
13
16
120 VAC
SV5
14
HOT GAS BYPASS SOLENOID
120 VAC 1.0 AMP MAX
120 VAC
12
N
17
DX EVAP. FAN PUMP RELAY
(BY OTHERS)
120 VAC 1.0 AMP MAX
ALARM BELL
OPTION
FACTORY SUPPLIED ALARM
FIELD WIRED
120 VAC
11
ALARM BELL RELAY
17
GND
TIME
CLOCK
AUTO
OFF
TB2
ON
REMOTE STOP
SWITCH
(BY OTHERS)
25
EVAP. FLOW SWITCH
---MANDATORY–(BY OTHERS)
843
IF REMOTE STOP CONTROL
IS USED, REMOVE LEAD 843
FROM TERM. 25 TO 35.
35
MANUAL
26
NOR. OPEN PUMP AUX.
CONTACTS (OPTIONAL)
ALARM BELL
RELAY
36
22
COM
NO
BELL
31
1
Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 2
ALARM BELL OPTION
23
STAGE 1 NOR. OPEN CONTACTORS
33
J5-ID7
34
J5-ID8
28
STAGE 2 NOR. OPEN CONTACTORS
DWG. 330539401 REV.0B Note: See control and power wiring diagrams on unit control panel for specific unit information. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 9 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 19 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
Sound Data Sound Pressure, w/o Sound Insulation ACZ Unit Model 63 125 250 010B 013B 016B 020B 025B 028B 033B 039B 52 52 53 58 58 58 59 61 52 52 54 56 57 58 59 62 52 52 54 55 56 56 61 63 Octave Band at Center Frequency 500 1000 2000 54 54 55 53 54 55 58 59 48 48 48 52 52 52 54 55 46 46 47 50 50 50 53 54 4000 8000 Overall A‐Weighted 44 44 45 48 48 48 51 53 42 42 42 48 48 48 50 51 55 55 56 57 58 58 61 63 Note: Data at 30 feet (9m) from side of unit; Q=2, unit on a flat roof or ground with no adjacent wall; Octave band readings are flat dB, overall is “A” weighted. Sound Power, w/o Sound Insulation ACZ Unit Model 63 125 010B 013B 016B 020B 025B 028B 033B 039B 79 79 80 85 85 85 86 88 79 79 81 83 84 85 86 89 Octave Band at Center Frequency (per ARI Standard 370) 250 500 1000 2000 4000 79 79 81 82 83 83 88 90 81 81 82 80 81 82 85 86 75 75 75 79 79 79 81 82 73 73 74 77 77 77 80 81 8000 Overall A‐Weighted 69 69 69 75 75 75 77 78 82 82 83 84 85 85 88 90 71 71 72 75 75 75 78 80 Note: Octave band readings are flat dB, overall is “A” weighted. Sound Pressure w/ Sound Insulation ACZ Unit Model 63 125 250 010B 013B 016B 020B 025B 028B 033B 039B 52 52 52 52 53 54 54 55 52 52 53 53 54 54 54 55 51 51 51 53 54 54 55 56 Octave Band at Center Frequency 500 1000 2000 52 52 53 54 55 55 56 57 46 46 47 47 48 48 49 50 45 45 45 45 46 46 47 48 4000 8000 Overall A‐Weighted 43 43 43 44 45 45 46 47 41 41 41 42 43 43 43 43 53 53 54 55 56 56 57 58 Notes: Data at 30 feet (9m) from side of unit; Q=2, unit on a flat roof or ground with no adjacent wall; Octave band readings are flat dB, overall is “A” weighted. Sound Power w/ Sound insulation Certified Drawings, AC Scroll Condensing Unit, ACZ010‐039B_Drawing for ACCU‐1001 ACZ Unit Model 63 125 010B 013B 016B 020B 025B 028B 033B 039B 79 79 79 79 80 81 81 82 79 79 80 80 81 81 81 82 Octave Band at Center Frequency (per ARI Standard 370) 250 500 1000 2000 4000 78 78 78 80 81 81 82 83 79 79 80 81 82 82 83 84 73 73 74 74 75 75 76 77 72 72 72 72 73 73 74 75 70 70 70 71 72 72 73 74 8000 Overall A‐Weighted 68 68 68 69 70 70 70 70 80 80 81 82 83 83 84 85 Note: Octave band readings are flat dB, overall is “A” weighted. Product Drawing Unit Tag: ACCU‐1001 Product: Air‐Cooled Condensing Unit Model: ACZ025‐039BS Project Name: Pasco WWTP
Sales Engineer: Greg Nelson Apr. 07, 2014
Sales Office: Vemco, Inc. (Spokane)
Ver/Rev: Sheet 10 of 10 13600 Industrial Park Blvd. Minneapolis, MN 55441 Software Version: 03.90
www.DaikinApplied.com Dwg Units: in [mm]
Scale: NTS Tolerance: +/‐1.0”
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: Job Name: DDBYD5 Pasco WWTP Page 20 of 21
Prepared Date:
4/7/2014 www.DaikinApplied.com
DAIKIN APPLIED AMERICAS INC.
LIMITED PRODUCT WARRANTY
(North America)
Daikin Applied Americas Inc. dba Daikin Applied (“Company”) warrants to contractor, purchaser and any owner of the product
(collectively “Owner”) that Company, at it’s option, will repair or replace defective parts in the event any product manufactured by
Company, including products sold under the brand name Daikin and used in the United States or Canada, proves defective in material
or workmanship within twelve (12) months from initial startup or eighteen (18) months from the date shipped by Company, whichever
occurs first. Authorized replaced parts are warranted for the duration of the original warranty. All shipments of such parts will be
made FOB factory, freight prepaid and allowed. Company reserves the right to select carrier and method of shipment.
In addition, labor to repair or replace warranty parts is provided during Company normal working hours on products with rotary screw
compressors, centrifugal compressors and on absorption chillers. Warranty labor is not provided for any other products.
Company’s liability to Owner under this warranty shall not exceed the lesser of the cost of correcting defects in the products sold or the
original purchase price of the products.
PRODUCT STARTUP ON ABSORPTION, CENTRIFUGAL AND SCREW COMPRESSOR PRODUCTS IS MANDATORY and
must be performed by a Daikin Applied or a Company authorized service representative.
It is Owner’s responsibility to complete and return the Registration and Startup Forms accompanying the product to Company within
ten (10) days of original startup. If this is not done, the ship date and the startup date will be deemed the same for warranty period
determination, and this warranty shall expire twelve (12) months from that date.
EXCEPTIONS
1.
2.
3.
If free warranty labor is available as set forth above, such free labor does not include diagnostic visits, inspections, travel time and
related expenses, or unusual access time or costs required by product location.
Refrigerants, fluids, oils and expendable items such as filters are not covered by this warranty.
This warranty shall not apply to products or parts which (a) have been opened, disassembled, repaired, or altered by anyone other
than Company or its authorized service representative; or (b) have been subjected to misuse, negligence, accidents, damage, or
abnormal use or service; or (c) have been operated, installed, or startup has been provided in a manner contrary to Company’s
printed instructions, or (d) were manufactured or furnished by others and which are not an integral part of a product manufactured
by Company; (e) have been exposed to contaminates, or corrosive agents, chemicals, or minerals, from the water supply source, or
(f) have not been fully paid for by Owner.
ASSISTANCE
To obtain assistance or information regarding this warranty, please contact your local sales representative or a Daikin Applied office.
SOLE REMEDY
THIS WARRANTY CONSTITUTES THE OWNER’S SOLE REMEDY. IT IS GIVEN IN LIEU OF ALL OTHER
WARRANTIES. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT AND UNDER NO CIRCUMSTANCE SHALL COMPANY BE LIABLE FOR INCIDENTAL,
INDIRECT, SPECIAL, CONTINGENT OR CONSEQUENTIAL DAMAGES, WHETHER THE THEORY BE BREACH OF
THIS OR ANY OTHER WARRANTY, NEGLIGENCE OR STRICT LIABILITY IN TORT.
No person (including any agent, sales representative, dealer or distributor) has the authority to expand the Company’s obligation
beyond the terms of this express warranty or to state that the performance of the product is other than that published by Company.
For additional consideration, Company will provide an extended warranty(ies) on certain products or components thereof. The terms
of the extended warranty(ies) are shown on a separate extended warranty statement.
Form No. 933-430285Y-00-A (10/13)
Download