618 E. 3rd St., Tulsa, OK 74120 ISSUE DATE: January 05, 2015 ADDENDUM 002 PROJECT: Hard Rock Lobby Renovation Addresses: Cherokee Nation Entertainment 777 W. Cherokee St. Catoosa, OK 74015 To: Prospective Bidders This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated 12.03.2014 as noted below. Please acknowledge receipt of this Addendum on the Bid Form. Failure to do so may subject Bidder to disqualification. APPROVED SUBSTITUTIONS Item A2-1. None. CLARIFICATIONS Item A2-2. Refer to Sheet AI600 Finish Legend. STF1 to be: Manufacturer: Global Granite (www.globalgranite.com) , Color: Blue Pearl. STF2 to be: Manufacturer: Global Granite, Color: Blanco Romano. STF3 to be: Manufacturer: Global Granite, Color: African Red. These items are a 10 week lead time. Contact at Global Granite: Sean Raithel – 314-426-1466, Email: seanr@globalgranite.com Item A2-3. Refer to Sheet AI610, Elevation 4 Check-In East: STF3 at desk front design to be 3cm Granite not 12x12 tile granite. Item A2-4. Tax Exempt materials over $500 - refer CHANGES TO SPECIFICATIONS below and provide breakout pricing. Item A2-5. No construction permit is required – refer CHANGES TO SPECIFICATIONS below. Item A2-6. Section 013300 – Submittal review time. Average review time is 3 days or less for TriArch and their consultants. Contractor may assume a 3 day review for scheduling purposes. Item A2-7. CONSTRUCTION STAGING. There is a small parking lot adjacent to the building on the west side just south of the rotunda entrance area. Contractor use this lot for staging, material lay-down, and construction trailer. Contractor responsible for providing construction trailer for temporary office within staging area. Contractor responsible for running temporary power to construction trailer from building to nearby supply as directed by Owner. Item A2-8. Strike Paragraph A. from Section 033053, 3.10. This Section calls for testing of any concrete being placed. This would have been applicable if there was concrete patching required. There is no concrete patching in the Project at this time, so this is not applicable. The Specification will be left in place in case any new saw Page 1 of 2 cutting and patchwork will be needed, at which time, the Owner will engage a testing agency at their discretion. Item A2-9. Owner will relocate, provide and install all access control devices and security cameras. Refer Electrical for exact requirements for Contractor. Item A2-10. A1610 sec. 5, Temp Check in. This section shows the customer side of the Temp. check in desk to be PL-2 Laminate. Is this correct? This is correct. Item A2-11. A1600 sec. 1, shows metal air vents. Will this section be “typical” for cabinets with doors in sec. 2A1610? Yes since the only place we have cabinet doors is at the main check in desk. Item A2-12. All Wainscot by the finish carpenter? Yes. Item A2-13. A1600 Room finish legend Millwork PL2 states a “Wilsonart” product but the style information is a “Formica” product. Should this read “Formica”? Yes- change manufacturer to Formica. CHANGES TO SPECIFICATIONS Item A2-14. Refer Specifications Section 007300 Supplementary Conditions, paragraph 3.6. Add 3.6.2 as follows: 3.6.2. PROVIDE BREAKOUT PRICING IN BID FOR TAXES ON MATERIALS INVOICED IN AMOUNTS OVER $500 OR MORE FOR OPTIONAL CONSIDERATION AS FOLLOWS: For any materials supplied by the Contractor with an invoice over $500.00, the Contractor may pass the invoice directly on to the Owner and the Owner will directly pay the invoiced amount using the Owner’s tax-free status. The Contractor shall then include any Ownerpaid invoice amounts in the Application for Payment as previously paid amounts. For invoices up to and including $500.00, the Contractor shall purchase the materials directly and pay any applicable taxes. Following this method, materials procured in amounts over $500.00 will be tax free, however, the Contractor is responsible for procuring the material and including the Cost of the material in their bid. Impact on the Project Schedule to be determined by Owner and successful bidder and taxation strategy to be determined post bid. Item A2-15. Refer Specifications Section 007300 Supplementary Conditions, paragraph 9.8.6 and make the following change: 9.8.6 Obtain City of Catoosa, Oklahoma, Occupancy Permit, and other applicable regulatory entity and consultant-based inspections and certificates of Substantial Completion. This project is located on Federal Trust land. No local municipal construction permit is required. CHANGES TO DRAWINGS Item A2-16. Item A2-17. Item A2-18. Item A2-19. Item A2-20. Item A2-21. Refer 1/A101. Add callout for temporary desk as indicated in attached. Refer 4/A102. Change angle on millwork counter as indicated in attached. Refer 5/A102. Delete access panel at columns as indicated in attached. Refer to Sheet AI601. Add interior elevations 8, 9, and 10. Refer to Sheet AI600. Add interior elevations 19 and 20. Make changes indicated in attached Drawings E201, E301, E401, E402, and M100. ATTACHMENTS 1. 2. A101, A102, AI600, AI601, revised 1.05.2014, 4 pages. E201, E301, E401, E402, M100, revised 1.05.2014, 5 pages. END OF ADDENDUM Page 2 of 2 PLC ARCHITECTURE DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) DN No. Description 1 2 Date Addendum 001 Addendum 002 12/29/2014 01/05/2015 REVISIONS DN GENERAL DEMOLITION NOTES 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. DEMOLITION PLANS ARE GENERAL AND DIAGRAMMATIC IN NATURE. THE PLANS ARE NOT INTENDED TO REPRESENT THE TOTAL SCOPE OF WORK. THESE PLANS DO NOT SHOW EACH ITEM THAT IS REQUIRED TO BE REMOVED. EACH CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE ACTUAL CONDITIONS AS THEY EXIST IN THE FIELD THROUGH SITE INSPECTION AND REVIEW OF THESE DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE AND COORDINATE THE REMOVAL AND DEMOLITION WORK AS REQUIRED TO ACHIEVE FINAL PRODUCT AS INDICATED IN THESE DOCUMENTS. REFER SUGGESTED PHASING PLANS, PHASING REQUIREMENTS, AND TEMPORARY CONSTRUCTION REQUIREMENTS AND PLAN ALL WORK ACCORDINGLY THE CONTRACTOR HAS DISCRETION OF MEANS AND METHODS TO REMOVE MORE MATERIAL THAN IS SHOWN ON THIS DEMOLITION PLAN AND RESTORE THOSE PORTIONS DURING NEW CONSTRUCTION IN ORDER TO SIMPLIFY ARRIVING AT THE FINISHED PRODUCT SHOWN. REMOVE ALL EXISTING FLOOR FINISHES WHERE NEW FINISHES ARE SCHEDULED. PREPARE EXISTING FLOOR SURFACE AS NECESSARY FOR NEWLY SCHEDULED FINISHES. WHERE NEW FINISH MATERIALS ARE SPECIFIED TO BE INSTALLED ON EXISTING SURFACES, PREPARE EXISTING SURFACE AS INDICATED BY FINISH MATERIAL MANUFACTURER TO RESULT IN AN APPROPRIATE, UNIFORM BASE SURFACE ON WHICH TO PLACE THE NEW FINISH MATERIAL. THE OWNER AND HIS DESIGNATED REPRESENTATIVES HAVE FIRST RIGHT OF REFUSAL REGARDING SALVAGEABLE ITEMS. CONTRACTOR SHALL COORDINATE WITH OWNER. PRIOR TO START OF DEMOLITION, OBTAIN DIRECTION FROM OWNER FOR BUILDING COMPONENTS TO BE KEPT AND STORED BY OWNER. EXISTING BUILDING PLANS IF AVAILABLE MAY BE REVIEWED UPON REQUEST. THESE PLANS SHALL NOT BE CONSIDERED ACCURATE AND COMPLETE AS TO THE CONDITIONS AS THEY EXIST IN THE FIELD. EXISTING STRUCTURAL SYSTEM SHALL NOT BE REMOVED OR MODIFIED UNLESS APPROVED IN ADVANCE BY THE ARCHITECT OR AS SPECIFICALLY OTHERWISE INDICATED. REMOVE EXISTING ITEMS AS REQUIRED FOR REUSE IN THE NEW PLAN OR NEW FINISH. catalog AND STORE ITEMS IN A SAFE STORAGE AREA SUBJECT TO THE OWNER'S APPROVAL UNTIL THE TIME OF REINSTALLATION. LOST ITEMS SHALL BE REPLACED WITH COMPARABLE NEW ITEM AT NO COST TO THE OWNER. PRIOR TO INITIATING DEMOLITION ACTIVITIES INDICATED, ENSURE THAT NO JURISDICTIONALLY REGULATED HAZARDOUS SUBSTANCE IS PRESENT WITHIN THE CONSTRUCTION AREA. IF A HAZARDOUS SUBSTANCE IS FOUND, NOTIFY THE ARCHITECT AND OWNER, AND OBTAIN THE OWNER'S DIRECTION CONCERNING DISPOSITION OF THE SUBSTANCE PRIOR TO PROCEEDING WITH THE WORK. ALL DEMOLITION ACTIVITIES SHALL COMPLY WITH APPLICABLE PROVISIONS OF FEDERAL, STATE, COUNTY AND LOCAL JURISDICTIONAL REGULATORY REQUIREMENTS. UNLESS INDICATED OTHERWISE, ALL DEMOLISHED MATERIAL EQUIPMENT AND RELATED ITEMS SHALL UPON REMOVAL BECOME THE PROPERTY OF THE CONTRACTOR AND BE DISPOSED OF IN STRICT ACCORDANCE WITH REGULATORY REQUIREMENTS. PRIOR TO INITIATING DEMOLITION ACTIVITIES, FIELD VERIFY EXISTING SPACE CONFIGURATION AND COMPONENTS INDICATED ON THE DRAWINGS. SHALL DISCREPANCIES EXIST, NOTIFY THE ARCHITECT AND OBTAIN THE ARCHITECT'S DIRECTION CONCERNING DISPOSITION OF THE DISCREPANCY PRIOR TO PROCEEDING WITH THE WORK. PROTECT EXISTING CONSTRUCTION TO REMAIN WITHIN CONSTRUCTION AREA AND BUILDING COMPONENTS OUTSIDE THE CONSTRUCTION AREA FROM DAMAGE DURING DEMOLITION ACTIVITIES. SHALL DAMAGE OCCUR, REPAIR DAMAGE AS REQUIRED TO RETURN THE DAMAGED COMPONENT TO ITS CONDITION PRIOR TO INITIATION OF THE WORK. SHALL REPAIR NOT BE FEASIBLE, CONSULT THE ARCHITECT FOR DISPOSITION OF THE DAMAGED COMPONENT. WHERE REQUIRED TO PROTECT EXISTING SPACES FROM DAMAGE AND/OR DUST NOISE AND CONSTRUCTION DEBRIS, PROVIDE TEMPORARY ENCLOSURES, BARRIERS, FILTERS AND OTHER TEMPORARY MEASURES REQUIRED TO PROVIDE PROTECTION. SHALL DEMOLITION ACTIVITIES REQUIRE ACCESS TO OR THROUGH EXISTING OCCUPIED PUBLIC OR PRIVATE SPACES, CONSULT THE OWNER FOR SPECIFIC ACCESS REQUIREMENTS, AND ADHERE STRICTLY TO THE OWNER'S REQUIREMENTS. MAINTAIN REQUIRED EXIT ACCESS CORRIDORS AND EXITS FREE AND CLEAR AT ALL TIMES UNLESS TEMPORARY OBSTRUCTION IS APPROVED BY JURISDICTIONAL REGULATORY AGENCIES. IF INDICATED IN THE DRAWINGS, VERIFY THAT FIRE RESISTANCE RATING INDICATED ON EXISTING WALLS ABUTTING CONSTRUCTION AREA COMPLIES WITH RATING INDICATED, INCLUDING OPENING PROTECTIVES. SHALL ANY PORTION OF THE ASSEMBLY NOT COMPLY WITH FIRE RESISTANCE RATING, CONSULT THE ARCHITECT TO DETERMINE CORRECTIVE MEASURES REQUIRED. IF MODIFICATIONS ARE MADE TO EXISTING FIRE PROTECTION AND FIRE RESISTIVE WALL OR FLOOR SYSTEMS RESTORE TO MAINTAIN THE REQUIRED RATING AND CONTINUITY. DN NOTE: REFER MEP, PHASING PLANS FINISH PLANS AND NOTES AND DEMOLITION NOTES FOR OTHER DEMOLITION REQUIREMENTS D DASHED LINES INDICATE ELEMENTS DO BE DEMOLISHED RELOCATE DOOR ACCESS HARDWARE TO CORRESPONDING NEW DOOR, REF. DOOR SCHEDULE Consultants B C 1 A DN DN 2 HARD ROCK LOBBY RENOVATION DN DEMOLITION PLAN 1/8" = 1'-0" CHEROKEE NATION ENTERTAINMENT, LLC 777 W. CHEROKEE ST. CATOOSA, OK 74015 1. DN AI601 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 144 128 EX. ELEV NEW WORK RM. 124 NEW OFFICE 125 ELV-2 126 EX. STOR. EX. VEST. EX. VEST 134 134.1 129 4 A102 125 Seal 129 OFOI COPIER 136 9 AI601 8 TEMP DESK N Key Plan EX LOBBY 5 A102 135 7 PROVIDE PERFORATED METAL AT SIDES AS SHOWN IN SECTION DETAILS-TYPICAL CORR 147 146 5 AI610 1 TEMPORARY RECEPTION DESK 2 A102 4 17 1 AI600 6 A102 Sim 141B RECESS LIGHTING FLUSH WITH GYPSUM BOARD IN WALLS AND CEILING REFER ELECTRICAL DRAWINGS VERIFY EXACT PLACEMENT WITH ARCHITECT DURING CONSTRUCTION 138 1 140 XFER VIP CHECKIN HP 140 HP 2 DISC PANEL FRONT DESK COPIER ROOM HP 141 141A 137 EX. STOR. AI610 138 145 6 145 DN DN AI600 3 A102 DN OVERALL CASINO 2 142B 2 HOTEL LOBBY AREA OF WORK ELV-3 126 136 144 12/03/2014 DN EX. ELEV TEMP COPIER 24' - 0" 134.2 16' - 0" 133 EXIST. MECH MECH 139 137 10 OFOI COPIER AI601 2 20 19 AI600 PROJECT NO. 01-1305 v.1.4_noSeal SHEET TITLE: 1 FLOOR PLAN 1/8" = 1'-0" DRAWN BY: CHECKED BY: ISSUE DATE: FLOOR PLAN & DEMOLITION PLAN Author Checker 12/03/2014 A101 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. 10. 143 130 100% CONSTRUCTION DOCUMENTS 8. 9. FUTURE SPA 142 123 EX. FIRE ELV-1 EX. VEST DN 8' - 0" 7. EXISTING JEWELRY STORE EX. MECH EX. STRS 0' 6. FUTURE SPA LOBBY EX. ELEC. 1/8" = 1' 5. EX. ELEV. LOBBY 122 EX. ELEV 3" 4. EX. DATA 2" 3. 128 1" 2. UNLESS INDICATED OTHERWISE, FLOOR PLAN DIMENSIONS ARE TO THE CENTER LINE OF NEW METAL STUD WALL CONSTRUCTION AND TO THE FINISHED FACE OF EXISTING CONSTRUCTION. WHERE REQUIRED TO ENSURE WALL STABILITY, DIAGONALLY BRACE TOP OF WALL ABOVE CEILING AT 4'-0" ON CENTER AND EACH SIDE DOOR SECURED TO STRUCTURE ABOVE. UNLESS INDICATED OTHERWISE, LOCATE HINGE SIDE OF DOOR OPENINGS 4" FROM FINISH FACE OF ADJACENT WALL. FIELD VERIFY FINISHED CASEWORK OPENINGS PRIOR TO FABRICATION OF CASEWORK. NOTIFY THE ARCHITECT AND OBTAIN THE ARCHITECT'S DIRECTION SHALL VERIFIED CASEWORK OPENING REQUIRE DIMENSIONAL RECONFIGURATION OF THE CASEWORK INDICATED. UNLESS INDICATED OTHERWISE, REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHT DESIGNATIONS. PROVIDE AND INSTALL BLOCKING, FRAMING AND / OR BRACING AS REQUIRED TO SECURELY INSTALL ALL OWNER AND CONTRACTOR FURNISHED EQUIPMENT OR WALL PROTECTION ASSEMBLIES OR GRAB BARS OR TOILET ACCESSORIES. VERIFY BLOCKING IS INSTALLED IN EXISTING WALLS TO RECEIVE OWNER OR CONTRACTOR FURNISHED EQUIPMENT OR WALL PROTECTION ASSEMBLIES. INSTALL PLUMBING AND ELECTRICAL FIXTURES AND DEVICES, MAKE CONNECTIONS TO EXISTING SYSTEM PER CODE REQUIREMENTS. REFER 'AI' DRAWINGS FOR INTERIOR ELEVATIONS AND ADDITIONAL INFORMATION. THE DRAWINGS AND SPECIFICATIONS, AND ALL COPIES THEREOF, ARE LEGAL INSTRUMENTS OF SERVICE FOR THE USE OF THE OWNER AND AUTHORIZED REPRESENTATIVES ON THE DESIGNATED PROPERTY ONLY. OTHER USE, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE ARCHITECT OF RECORD, IS PROHIBITED SPECIFICATIONS, DETAILS AND SCHEDULES WHICH MAY BE BOUND SEPARATELY ARE PART OF THESE CONTRACT DOCUMENTS. DRAWINGS BY CONSULTING PROFESSIONALS, SUCH AS STRUCTURAL, LANDSCAPE, ETC. ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS AND ARE PART OF THESE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY OMISSIONS OR DISCREPANCIES BETWEEN THE ARCHITECTURAL DRAWINGS, CONSULTING PROFESSIONAL'S DRAWINGS, SPECIFICATIONS OR EXISTING CONDITIONS. SHOULD THERE BE AN OMISSION OR DISCREPANCY BETWEEN SAID DRAWINGS, SPECIFICATIONS OR CONDITIONS, IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IN WRITING FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF INFORMATION IS NOT SHOWN OR UNCLEAR THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO STARTING WORK AND REPORT ANY DISCREPANCIES IN WRITING TO THE ARCHITECT. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FOR ALL WORK THE CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING THE WORK FOR ALL UTILITIES AND SERVICES ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. QUESTIONS REGARDING THE SAME, OR THEIR EXACT MEANING, SHOULD BE DIRECTED TO THE ARCHITECT WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT AND CONFIGURATION OF THE BUILDING ON THE SITE ALL EXISTING WALL DIMENSIONS ARE TO INSIDE FACE OF STUD, FACE OF CONCRETE OR MASONRY UNLESS NOTED OTHERWISE. INTERIOR WALL DIMENSIONS ARE TO CENTER LINE OF WALL UNLESS NOTED OTHERWISE FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS NOTED CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACKING, HANGERS, BACK-UP PLATES, AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET ROOM ACCESSORIES, FIXTURES, PARTITIONS AND ALL WALLMOUNTED OR SUSPENDED MECHANICAL, KITCHEN, ELECTRICAL OR MISCELLANEOUS EQUIPMENT AND FURNISHINGS CONTRACTOR SHALL VERIFY EXACT SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT PADS, BASE STRUCTURES, ROOF OPENINGS, AS WELL AS POWER, WATER, DRAIN INSTALLATIONS AND STRUCTURAL STEEL SUPPORT LOCATIONS WITH EQUIPMENT MANUFACTURERS BEFORE PROCEEDING WITH THE WORK. CHANGES TO ACCOMMODATE FIELD CONDITIONS OR APPROVED SUBSTITUTIONS SHALL BE MADE WITHOUT ADDITIONAL CHARGE TO THE OWNER 0" 142A 1. 4" S1 GENERAL PLAN NOTES 32' - 0" AI601 S2 0' - 3 1/4" 0' - 2 7/8" WALLCOVERING OVER 5/8" HIGH IMPACT GYP. ON 1 5/8" LGMF AT 1'-4" O.C.-TYPICAL 2 NO ACCESS PANEL 7' 3' - 5/8" GYP. BOARD CLAD IN WALLCOVERING 0" AI610 1' 0" 8 8' - 6" 153° " 0' - 1 1/2" 0" '-0 33 EXISTING STRUCTURAL COLUMN - PAINT BRIGHT WHITE FOR REFLECTION OF LIGHTING TEMPORARY RECEPTION DESK REFER ELEVATIONS AND DETAILS 5 1 2 Date Addendum 001 Addendum 002 12/29/2014 01/05/2015 REVISIONS GYP CEILING INFILL AT 1" ABOVE HIGHEST ADJACENT CEILING REFER CEILING PLAN NO ACCESS PANEL PLAN SECTION COLUMN PLAN DETAIL 3" = 1'-0" Description CONTINUOUS LED STRIP LIGHTING FULL HEIGHT OF COLUMN COVER ADHERED TO LGMF - REFER ELECTRICAL 0' - 10 1/2" 2' - AI610 No. 1/4" ROUND NEODYMIUM MAGNET RETAINERS AT 1'-0" OC VERTICAL RECESS AND ADHERE TO SUBSTRATE WITH 3M SCOTCH-WELD OR APPROVED EQUAL AT BASE OF COLUMN - 6" HIGH 20 GAUGE STAINLESS STEEL BASE ADHERED TO 6" HIGH PLYWOOD FASTENED TO COLUMN WITH LGMF CLIP ANGLES PLANNING FRY REGLET 'Z' REVEAL GYP CORNER AND MAGNET MOUNT 5 A102 9 DESIGN 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) REMOVABLE RESIN PANEL FABRICATED IN (2) SECTIONS BOTTOM OF PANEL AT 4" AFF AND BREAK AT 16" AFF RP1 - REFER TO FINISH LEGEND, SHEET AI600 0' - 3 3/4" 6" GROMMETS-GR1CENTER 1 OVER EACH COMPUTER STATION AND 1 OVER EACH PRINTER STATION ARCHITECTURE FRY REGLET 5/8"X1/2" 'F' TRIM TO RETAIN PANEL AND FINISH GYP CORNER - WRAP BOTTOM WITH LGMF AND RIVET TO REGLET TO PROVIDE CLOSURE THAT WILL HOLD UP ACRYLIC 0' - 3" 1 5/8" BRACING WITH CLIP ANGLE BACK TO STRUCTURAL COLUMN AS NEEDED. START AT 6" ABOVE BASE OF COLUMN SUSPEND COLUMN WRAP ASSEMBLY FROM STRUCTURE ABOVE OR FRAME BACK TO AND SUSPEND FROM COLUMNS PROVIDE CORNER GUARD-CG1 AT ALL OUTSIDE CORNERS-TYPICAL 0' - 1 1/2" 1' - 0" PLC 1' - 6 5/8" REFLECTED CEILING DETAIL 2 1 9' - 6" 2 WRAP DESK DESIGN AROUND SIDES WHERE EXPOSED, TYPICAL 4' - 0" 2' - 7" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" Consultants -8 2 " AI610 10 12 AI610 10 GROMMETS-GR 11 CENTERED AT EACH COMPUTER STATION AND 1 AT EACH PRINTER STATION AI610 AI610 AI600 5/8" GYP BD ONE SIDE 3 5/8" LGMF INFILL WALL ALIGN 6 5' - 10" 17 AI610 4' - 0" 1' - 0" 4' - 0" GROMMETS GR1 EVERY 3'-0" O.C. OR AS DIRECTED BY OWNER-TYPICAL 225 ° 2' 4' - 0" 7' - 0" 2' - 0" SUPPORT BRACKET BR1 EVERY 3'-0" O.C.-TYPICAL 4' - 0" 2' - 6" GROMMETS-GR1CENTER 1 OVER COMPUTER STATION AND 1 OVER PRINTER STATION, TYPICAL 3' - 6" 6 ENLARGED TEMPORARY DESK 1/4" = 1'-0" STORAGE FILES TO CREATE ADDITIONAL STRUCTURAL SUPPORT FOR COUNTERTOPS 13 2' -8 43' - 10" " PONY WALL AT 3'-6" HIGH 3 126 2 CHECK-IN DESK 1/4" = 1'-0" 2' - 11" 1 AI610 16 AI610 ° 225 14 1' - 6" 2 3 4 5 6 6.7 8 8.3 9.5 10 11 12 13 14 WORK ROOM 126 1/4" = 1'-0" W DN V U T 3A1 98 ° 3A0 11' - 3" HOTEL LOBBY AREA OF WORK 2N0 2N0 155° 3A0 3A0 3A0 4' - 5" 3A0 3A0 3A0 3A0 3A0 2N0 N 133° Key Plan 3' - 0" 1' - 0" 3' - 0" 1' - 0" 3' - 0" 1' - 0" 3' - 0" 3' - 0" 3A0 169° 6' - 0" 3' - 0" 3A0 3A1 B. INSULATION TYPE A. ACOUSTICAL T. THERMAL N. NONE C . WALL HEIGHT L. LOW WALL - DOES NOT REACH CEILING, REF. ELEVATIONS FOR WALL HEIGHT H. HIGH WALL - WALL STUDS AND GYP SEAL TIGHT TO BOTTOM OF CEILING 0. WALL STUDS AND GYP END 6" ABOVE CEILING 1. WALL STUDS AND ONE SIDE GYP EXTEND TO DECK 2. WALL STUDS AND BOTH SIDES GYP EXTEND TO DECK 3° 3' - 10" 3' - 1" M 3A0 8° !. CODE RATING ° 93 11' - 2" 3A0 3NL N DN ALIGN 3A1 ALIGN DN XZX 2" 8' - 0" 1" 4' - 0" 15 100% CONSTRUCTION DOCUMENTS 1' - 0" 3' - 0" 1' - 0" 4" 7° 7' - 0" 3A0 8' - 5" 6' - 5" 14' - 3" 2' - 2" INTERIOR PARTITION LEGEND DN GENERAL NOTES 1. INSTALL 5/8" GYPSUM BD UltraLight FIRECODE PANELS AT ALL EXPOSED SIDES OF STUDS. 2. INSTALL MOLD & MOISTURE RESISTANT GYP BD NO LESS THAN 4' 0" FROM ALL PLUMBING FIXTURES. 3. INSTALL CEMENTITIOUS TILE BACKER BOARD BEHIND ALL TILE. PROJECT NO. 01-1305 v.1.4_noSeal SHEET TITLE: DIMENSION PLAN & ENLARGED PLANS 0' DIMENSION PLAN 1/8" = 1'-0" 1/4" = 1' 1 0" ABC ° 65 10' - 0" 3A0 3A0 4' - 7" 3A0 OVERALL CASINO 3' - 0" 153° 3A1 R 2N0 7' - 0" 6A0 2N0 3' - 10" 2' - 0" 3A1 3A0 A. WALL CORE WIDTH 0. 7/8" HAT CHANNELS 1. 1 5/8" METAL STUDS 2. 2 1/2" METAL STUDS 3. 3 5/8" METAL STUDS 4. 4" METAL STUDS 6. 6" METAL STUDS T. TWO 3 5/8" METAL STUDS WITH 1 3/4" AIR SPACE 2N0 3A0 3A0 25° 1' - 5" CL COL - FOW 2N0 2N0 27° P 3A1 2N0 82 ° ALIGN 8° Q 3A1 ALIGN 2N0 3NL 7' - 6" 2N0 3A0 12/03/2014 14' - 4" 16' - 0" 13' - 5" 12' - 0" 15' - 5" 3" 3A0 Seal DN DRAWN BY: CHECKED BY: ISSUE DATE: Author Checker 12/03/2014 A102 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. DN 11 4 VIP CHECK IN 140 1/4" = 1'-0" VIDEO WALL 1' - 6" 2' - 0" 82 ° ON CHASE SIDE INSTALL TRANSLUCENT GLAZING FILM OVER PORTION OF GLAZING LOOKING INTO MECHANICAL CHASE CHEROKEE NATION ENTERTAINMENT, LLC 777 W. CHEROKEE ST. CATOOSA, OK 74015 2' - 7" 4" BACKSPLASH HARD ROCK LOBBY RENOVATION NEW WORK RM. 225 ° 15 PLC 0' - 9" ROOM FINISH LEGEND SPECIALTIES SCHEDULE ARCHITECTURE DESCRIPTION MFGR. DIVISION 6 - ARCHITECTURAL WOODWORK BR1 METAL COUNTER SUPPORT BRACKET GR1 3" GROMMET DIVISION 10-FIRE PROTECTION SPECIALTIES FE FIRE EXTIGUISHER FEC FIRE EXTIGUISHER CABINET- SEMI RECESSED DIVISION 10-SHEETWALL PROTECTION CG1 EXTRUDED CORNER GUARD DIVISION 12- WINDOW TREATMENTS WB1 1" ALUMINUM MINI BLINDS MFGR. # DIMENSIONS FINISH RESPONSIBILITY TMI SYSTEMS DOUG MOCKETT A7453 MM5-21 3"W x AS REQUIRED 3" BLACK BLACK METALLIC CP & I CP&I LARSEN'S LARSEN'S VERTICAL DUO RE: SPECS RE: SPECS RE: SPECS RE:SPECS STAINLESS STEEL CP & I CP & I KOROGARD G825 3/4" WING MULTIPLE-TO MATCH ADJACENT WALLS CP&I LEVOLOR RIVIERA AS REQUIRED BRUSHED ALUMINUM CP&I REMARKS PROVIDE BLOCKING ROOM FINISH SCHEDULE # Name 125 126 128 134 134.1 134.2 135 136 137 138 140 141 146 147 Floor Finish NEW OFFICE NEW WORK RM. EX. ELEV. LOBBY EX. VEST. EX. VEST EX. VEST EX LOBBY TEMP COPIER MECH FRONT DESK VIP CHECKIN COPIER ROOM CORR TEMP DESK CA1 CA1 STF1/STF2 STF2 STF2 STF2 ETR/STF1/STF2 CA1 SC CA2 CA2 CA2 STF1/STF2/STF3 ST1/STF2/STF3 Base Finish RB1 RB1 STF2 STF2 STF2 STF2 STF2 RB1 RB1 RB1/STF2 RB1 RB1 STF2 RB1/STF2 1 1 North Wall P1 P1 WC1/WC8 ETR WC1 WC1 WC1/WC8 P1 P1 WC1 WC1 P1 WC1/WC8 P2 East Wall P1 P1 WC1/WC8 ETR WC1 WC1 WC1/WC8 P1 P1 WC2/WC7 WC1 P1 WC1/WC7/WC8 P2 FLOORING STF1 MANUFACTURER: AS REQUIRED STYLE: GRANITE COLOR: MATCH EXISTING BLUE PEARL-OWNER TO APPROVE RUN SIZE: 12"X12" GROUT: MATCH EXISTING STF2 MANUFACTURER: AS REQUIRED STYLE: GRANITE COLOR: MATCH EXISTING CREAM COLORED GRANITEOWNER TO APPROVE RUN SIZE: 12"X12" GROUT: MATCH EXISTING STF3 MANUFACTURER: AS REQUIRED STYLE: GRANITE COLOR: MATCH EXISTING RED GRANITE (INDIAN RED MULTI)-OWNER TO APPROVE RUN SIZE: 12"X12" GROUT: MATCH EXISTING CA1 MANUFACTURER: MASLAND CONTRACT STYLE: LINGO MODULAR COLOR: T508-50807 SCUTTLEBUTT 1 SIZE: 24"X24" INSTALLATION: QUARTERTURN CA2 MANUFACTURER: MASLAND CONTRACT STYLE: MERGE COLOR: T7860-68003 STERLING 1 *PROVIDE COMMERCIAL GRADE 18 POUND DOUBLE STICK CARPET PAD WITH THIS PRODUCT SC SEALED CONCRETE BASE 1 RB1 MANUFACTURER: ROPPE STYLE: 4" RUBBER COVE BASE COLOR: P100 BLACK STF2 MANUFACTURER: AS REQUIRED STYLE: GRANITE COLOR: MATCH EXISTING CREAM COLORED GRANITEOWNER TO APPROVE RUN SIZE: 4"H x AS NEEDED CEILINGS GYP. GYPSUM WALL BOARD CP1 MANUFACTURER: CHEMETAL STYLE: POLISHED CHROME 801 SIZE: 24"X24 MOUNTED ON 3/8" PLYWOOD GRID SYSTEM: ARMSTRONG 9/16" COLOR: PROVIDE PLATINUM AND SILVER SATIN SAMPLES FOR SELECTION CP2 MANUFACTURER: 3 FORM STYLE: RAY COLOR: PEWTER SIZE: 4'X8' *MATCH PATTERN REPEAT CP3 3/8" FROSTED ACRYLIC ACT1 MANUFACTURER: USG CEILING SYSTEMS STYLE: ASTRO CLIMAPLUS CEILINGS SIZE: 24"X48" COLOR: WHITE GRID SYSTEM: ANGLED TEGULAR SIZE: 15/16" COLOR: WHITE 2 South Wall P1 P1 WC1/WC8 ETR WC1 WC1 WC1/WC8 P1 P1 WC7 WC1 P1 WC1 P2 West Wall Ceiling Finish P1 P1 WC6/WC8 ETR WC1 WC1 WC1/WC8 P1 P1 NA WC1 P1 P2/MF1/M1/M2/WC1/WC8 P2 Comments ACT1 ACT1 CP1/CP2/FROST. ACR./GYP. ETR ETR ETR ETR ACT1 ACT1 CP1/CP2/FROST. ACR/GYP. ACT1 ACT1 CP1/CP2/FROST. ACR/GYP. CP1/CP2/FROST. ACRYLIC 2 2 3 1,2,3 1,2,3 WALLS PAINT P1 MANUFACTURER: SHERWIN WILLIAMS COLOR: SW7050 USEFUL GRAY P2 MANUFACTURER: SHERWIN WILLIAMS COLOR: 7003 TOQUE WHITE P3 MANUFACTURER: MODERN MASTERS STYLE: METALLIC PAINT COLLECTION COLOR: BLACKENED BRONZE ME238 TINT WALL FINISHES WC1 MANUFACTURER: SOURCE ONE 2 STYLE: TOKAGE COLOR: SGG-07 NEUTRA WC2 MANUFACTURER: LANARK STYLE: MOD COLOR: L2-MO-10 WC3 MANUFACTURER: SOURCE ONE STYLE: LUSTROUS COLOR: LLU-02 SKI LIFT WC4 NOT USED WC5 NOT USED WC6 MANUFACTURER: SOURCE ONE STYLE: PRESTON COLOR: 2VPS-03 TAUPE WC7 MANUFACTURER: COLOUR AND DESIGN STYLE: ZUNA COLOR: CD2-ZUN-08 CHIPOLTE MF1 MANUFACTURER: ADVANCED TECHNOLOGIES INC. STYLE: MIRROFLEX, RANDOM LINES COLOR: CROSSHATCH SILVER SIZE: 4'X8' *PROVIDE COORDINATING TRIM PIECES AT ALL CORNERS, OUTSIDE/EXPOSED EDGES M1 1/4" TEMPERED GLASS MIRROR 20 GAUGE STAINLESS STEEL FINISHED TO NO. 8 ARCHITECTURAL BRIGHT FINISH SIZE: CUSTOM M2 MANUFACTURER: TWO WAY MIRRORS STYLE: GLASS 2-WAY MIRROR, 1/4" TEMPERED GLASS SIZE: CUSTOM MILLWORK QZ1 MANUFACTURER: DUPONT STYLE: ZODIAQ COLOR: LICORICE SIZE: 3CM PL1 MANUFACTURER: WILSONART STYLE: 4968-38 URBAN IRON PL2 MANUFACTURER: FORMICA STYLE: 8826-58 NEUTRAL TWILL MISCELLANEOUS BO BY OTHERS ETR EXISTING TO REMAIN FINISHED CEILING No. Description 1 2 INFILL AT ENDS PERFORATED METALMCNICHOLS 1433312238 FINISH: STAINLESS STEEL KEYED FINISH REMARKS: 1. TEMPORARY WALLS TO BE PAINTED P2 AND RECEIVE RUBBER BASE RB1. 2. PROVIDE WAINSCOTT W/ PATTERN CLAD IN MF1 AS SHOWN IN ELEVATION 6, SHEET AI610 AT ALL WALLS 3. APPROVED VENDORS FOR WATER JET CUTTING: CRIMSON CUTTING SOLUTIONS: 918-852-4954 WATER JET WORKS: 972-991-0972 DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) Date Addendum 001 Addendum 002 12/29/2014 01/05/2015 18 AI600 REVISIONS 5/8" GYP. BOARD ON 3 5/8" METAL STUD FRAMING @ 1'-4" OC TYP GENERAL NOTES: 1. ALL HOLLOW METAL DOORS, DOOR FRAMES, AND WINDOW FRAMES TO BE PAINTED P1 2. ALL WINDOW SILLS AND APRONS TO HAVE GYP. BOARD RETURNS 3. PROVIDE APPROPRIATE RUBBER TRANSITION STRIPS AT FLOORING CHANGES 4. MILLWORK DETAILS ARE PROVIDED AS AN OVERALL BASIS OF DESIGN. PROVIDE MILLWORK DETAILS COMPLIANT WITH SPECIFICATIONS AND TYPICAL CONSTRUCTION STANDARDS TO BE APPROVED THROUGH SHOP DRAWINGS AND SUBMITTAL PROCESS. 5. CEILING DETAILS ARE PROVIDED AS AN OVERALL BASIS OF DESIGN. PROVIDE CEILING DETAILS COMPLIANT WITH SPECIFICATIONS AND TYPICAL CONSTRUCTION STANDARDS FOR CEILINGS. 6. PROVIDE CORNER GUARDS(CG1-REFER TO SPECIATLIES SCHEDULE) AT ALL INTERIOR OUTSIDE CORNERS. 7. ALL STAINED WOOD DOORS TO BE STAINED TO MATCH EXISTING ADJACENT. METAL STUD BRACING BACK TO STRAIGHT WALL SYMMETRICAL AT OTHER END INFILL BOTH ENDS PERFORATED METALMCNICHOLS 1433312238 FINISH: STAINLESS STEEL LINE OF METAL FRAMING BELOW - CUT OUT AT GYP. BOARD FOR AIR RETURN ONLY AT CHASE LOCATION. CUTOUT 6'-0" HIGH X 2'-0" WIDE. SET 1'-0" AFF 1/2"X1/4" GLAZING CHANNEL BOTH SIDES TO RETAIN INFILL PANEL 90 ° WRAP WALL COVERING AROUND BACK EDGE TYPICAL METAL STUD BRACING BACK TO STRAIGHT WALL 0' - 4" MARK METAL STUD BRACING BACK TO STRAIGHT WALL Consultants 0' - 1" 7 Sim 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL AI600 FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL MIRROFLEX-MF1, TYPICAL FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL 1/4" MIRRORED GLASS REF. FINISH SCHED ° 80 ° 82 ° 80 97 ° 93 ° 1/4" MIRRORED GLASS REF. FINISH SCHED 5/8" GYP BD ON MTL STUD 0' - 2" PROVIDE FRY REGLET 1/2", "J" MOLD AT TOP AND BOTTOM. FINISH: ANNODIZED PROVIDE FRY REGLET 1/4" OPENING "H" AND "J" MOLDS AT PERIMETER AND TRANSITIONS FINISH: ANODIZED PROVIDE FRY REGLET 1/2", "H" MOLD AT TOP AND BOTTOM. FINISH: ANNODIZED PROVIDE FRY REGLET 1/2", "J" MOLD AT TOP AND BOTTOM. FINISH: ANNODIZED 4" HIGH GRANITE BASE WAINSCOT MAT'L REF. FINISH SCHED. 5/8" GYP BD ON MTL STUD 2 LAYERS 3/4" PLYWOOD 1/4" 2-WAY MIRRORED GLASS REF. FINISH SCHED 4" HIGH GRANITE BASE 5/8" GYP BD ON MTL STUD 0' - 10" 0' - 11" 2' - 11" 3' - 7" 1' - 7" 1' - 9" 3' - 6" 3' - 1" 2' - 0" 1' - 10" 3' - 3" 1' - 2" 1' - 8" 3' - 3" 2' - 4" 1' - 10" 3' - 1" 3' - 5" 1' - 9" 1' - 4" 3' - 7" 2' - 3" EXISTING HANDRAILS TO REMAIN 2' - 6" 0' - 0 1/4" VERIFY DIMENSIONS WITH EXISTING WALL CONDITIONS EXISTING HANDRAILS TO REMAIN 20 VERIFY DIMENSIONS WITH EXISTING WALL CONDITIONS LOBBY 135 RAMP SE 1/4" = 1'-0" 19 M 2 16 LOBBY 135 RAMP NW 1/4" = 1'-0" DTL PLAN - WINDOW / MIRROR TRANSITION 6" = 1'-0" 15 DTL PLAN - MIRROR / MIRROR TRANSITION 6" = 1'-0" 14 DTL SECTION - BASE / MIRROR TRANSITION 6" = 1'-0" 13 DTL SECTION - BASE / WAINSCOTT TRANSITION 6" = 1'-0" 1' - 1" 2 2' - 0" PLAM CLAD 3/4" MDF COUNTERTOP,AND NOSING BRACE FRAMING 4'-0" OC ADJUSTABLE SHELVING 5/8" GYP. BOARD SUBSTRATE 0' - 5 7/8" 0' - 1" SERVICE VALANCE ON HINGE - PERFORATED METAL (REFER FINISH LEGEND) ADHERED TO BLACK MELAMINE CLAD 1/2" MDF ON BLUM FULL OVERLAY CABINET HINGES 2'-0" OC ATTACHED TO CONTINUOUS 2X4 NAILER PUNCH DRYWALL TO ALLOW FOR 2 WAY MIRROR. PROVIDE 1' OF DRYWALL AT TOP AND BOTTOM AND 4" OF DRYWALL AT SIDES TO ADHERE MIRROR TO WALL PLANAR VIDEO SCREEN AND MOUNT BY OWNER DIMENSIONS 43.81' W X 4.49' H X 3.32" D - VERIFY WITH OWNER BEFORE FRAMING 2' - 1" 7' - 0" BOX BOX FILE 1" = 1'-0" CONTINUOUS 3/4" PLYWOOD BACKING ON 3 5/8" METAL FRAMING PAINT MATTE BLACK 2' - 0" PLAM CLAD 3/4" MDF COUNTERTOP, SPLASH, AND NOSING 2-WAY MIRROR-M2 5/8" GYP. BOARD SUBSTRATE 5/8" GYP. BOARD SUBSTRATE 0' - 1" PLAM CLAD 3/4" MDF COUNTERTOP,AND NOSING PROVIDE GYP. BOARD RETURN AT OFFICE SIDE OF WINDOW-TOP, BOTTOM, AND SIDES 2X6 METAL STUD FRAMING PLAM CLAD FILE DRAWER SCHEDULED HARDWARE Seal 2X6 METAL STUD FRAMING 0' - 10" 1/2" PLYWOOD CLAD IN 1/8" MF1 PROVIDE FRY REGLET "J" MOLD AT TOP, BOTTOM, AND SIDES. FINISH: ANNODIZED EXISTING WALL PLAM CLAD FILE DRAWER SCHEDULED BASE 1"X4" WOOD BASE SCHEDULED BASE PROVIDE FRY REGLET "J" MOLD AT TOP AND BOTTOM. FINISH: ANODIZED 10 OVERALL CASINO 9 SCREEN WALL SECTION 1 1/2" = 1'-0" PROVIDE FRY REGLET "J" MOLD AT TOP AND BOTTOM. FINISH: ANNODIZED 4" HIGH GRANITE BASE 8 DTL-MLW-DECORATIVE MIRROR WALL 3/4" = 1'-0" PLAM CLAD CABINET DOORS 1"X4" WOOD BASE 4" HIGH GRANITE BASE FILE FILE 1" = 1'-0" HOTEL LOBBY AREA OF WORK PLAM CLAD 3/4" MDF ADJUSTABLE SHELVING 3 5/8" METAL FRAMING WITH STUDS AT 1'-4" OC FASTEN WALLS TOGETHER 1' - 0" 1' - 0" 1LAYER 1/2" PLYWOOD CLAD IN MIRROR-M1 DTL-MLW-2-WAY MIRROR 3/4" = 1'-0" SCHEDULED BASE 4" HIGH GRANITE BASE 7 N 6 DTL-MLW-DECORATIVE WALL 3/4" = 1'-0" Key Plan STANDARD MILLWORK-UPPER AND LOWER CABINET 1" = 1'-0" 3' - 6" 2' - 6" 3/4" PLYWOOD TRANSACTION COUNTER CLAD IN PLASTIC LAMINATE 3' - 6" 3MM QUARTZ TRANSACTION COUNTER 1' - 0" 4" 1' - 0" 3' - 6" 1' - 0" 4' - 0" 3' - 6" 3/4" PLYWOOD TRANSACTION COUNTER CLAD IN PLASTIC LAMINATE 1' - 0" 2' - 6" QUARTZ TRANSACTION COUNTER 2X4 STUD FRAMING 1x4 WOOD BRACING 4" RUBBER COVE BASE PULL OUT PRINTER TRAY ON HEAVY DUTY FULL EXTENSION SLIDES 4" RUBBER COVE BASE BRUSHED 2" STAINLESS STEEL PIPING SPLIT AND MOUNTED TO FACE OF DESK 3' - 0" 3" 2' - 0" LED BACK LIGHTING LOCATION PROVIDE REMOVEABLE MILLWORK ACCESS PANELS FOR BACK LIGHTING 1' - 0" SCHEDULED HARDWARE 2" BRUSHED 2" STAINLESS STEEL PIPING SPLIT AND MOUNTED TO FACE OF DESK 2X4 STUD FRAMING PLAM CLAD 3/4" PLYWOOD FIXED SHELVING 1/4" FROSTED ACRYLIC PANEL GT METAL AIR VENT GRILLEDOUG MOCKETT, MESH 1 SIZE: 8W"X6H" COLOR: GRAY 2X4 STUD FRAMING 4" RUBBER COVE BASE 4 DTL-MLW-TEMP. DESK PRINTER STORAGE 1" = 1'-0" 3 DTL-MLW-TEMP. DESK COMPUTER STATION 1" = 1'-0" 4" RUBBER COVE BASE 2 DTL-MLW-CHECK-IN DESK PRINTER STORAGE 1" = 1'-0" v.1.4_noSeal SHEET TITLE: 1 DTL-MLW-CHECK-IN DESK COMPUTER STATION 1" = 1'-0" SCHEDULES & DETAILS 0' 1" = 1' 5 DTL-MLW-WAINSCOTT 3/4" = 1'-0" PROJECT NO. 01-1305 1x4 WOOD BRACING 0" 4" HIGH GRANITE BASE 3MM GRANITE DESIGN AT FACE OF DESK PROVIDE ACCESS PANEL FOR BACK LIGHTING 0' - 2" PLAM CLAD 3/4" PLYWOOD FIXED SHELVING PULL OUT PRINTER TRAY ON HEAVY DUTY FULL EXTENSION SLIDES PROVIDE FRY REGLET 1/2", "J" MOLD AT TOP AND BOTTOM. FINISH: ANNODIZED 2' - 10" 2X4 STUD FRAMING SCHEDULED HARDWARE PULL OUT KEYBOARD TRAY 3/4" PLYWOOD CLAD IN PLASTIC LAMINATE 2' - 10" 1/2" PLYWOOD CLAD IN 1/8" MF1 3/4" PLYWOOD CLAD IN PLASTIC LAMINATE 2' - 10" 3' - 2" 2X6 METAL STUD FRAMING 3' - 6" LED BACK LIGHTING LOCATION LED LIGHTING 0' - 3" 3M GRANITE DESIGN AT FACE OF DESK 3MM QUARTZ COUNTERTOP, SPLASH, AND NOSING 0' - 5" LED LIGHTING 0' - 6" 1" QUARTZ COUNTERTOP, SPLASH, AND NOSING 2' - 10" PULL OUT KEYBOARD TRAY 0' - 8" 0' - 6" 3/4" PLYWOOD COUNTERTOP, NOSING, AND SPLASH CLAD IN PLASTIC LAMINATE SCHEDULED HARDWARE PROVIDE FRY REGLET "T" MOLD 1/2"X1/2" 2' - 6" 3' - 6" 5/8" GYP. BOARD SUBSTRATE-CLAD IN WALLVOVERING ABOVE WAINSCOTT 0' - 8" 0' - 8" 0' - 8" 2' - 6" PLAM CLAD 3/4" PLYWOOD COUNTERTOP, SPLASH, AND NOSING 12/03/2014 2' - 10" 2' - 6" 2X6 METAL STUD FRAMING PLAM CLAD FILE CABINET FRONTS 11 DRAWER LINE OF JAMB BEYOND 3' - 9" 0' - 10" 1' - 0" SCHEDULED HARDWARE PLAM CLAD CABINET DOORS ALIGN AND LEAVE 3/16" GAP WRAPVWC INTO OPENING ON ALL GYP RETURNS 4' - 6" 5' - 3 1/2" 12 CLEAR OPEN 0' - 5" PLAM CLAD FILE DRAWER SCHEDULED BASE 3/4" MDF SHELVING PROVIDE GYP. BOARD RETURN AT OFFICE SIDE OF WINDOW-TOP, BOTTOM, AND SIDES PLAM CLAD FILE CABINET FRONTS 1"X4" WOOD BASE BOX HEADER TYPICAL ALL FRAMED OPENINGS 100% CONSTRUCTION DOCUMENTS 2' - 6" SCHEDULED HARDWARE NEW CEILING REFER CEILING PLAN 2' - 6" DRAWER 1' - 8" 1' - 0 1/4" +/- SCHEDULED HARDWARE DRAWN BY: CHECKED BY: ISSUE DATE: Author Checker 12/03/2014 AI600 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. 8' - 6" 8' - 6" ° 93 EXISTING TO BOTTOM OF RAMP WAINSCOTT MAT'L REF. FINISH SCHED. 1/4" MIRRORED GLASS REF. FINISH SCHED 5/8" GYP BD ON MTL STUD ° 83 10 0° 98 ° ° 83 ° 84 10 0° 93 ° 87 ° MIRROFLEX-MF1, TYPICAL DTL-ANGLE WALL SECTION 3/4" = 1'-0" CHEROKEE NATION ENTERTAINMENT, LLC 777 W. CHEROKEE ST. CATOOSA, OK 74015 FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL 17 DTL-ANGLE WALL PLAN SECTION 1 1/2" = 1'-0" HARD ROCK LOBBY RENOVATION 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL 18 AI600 0' - 4" 7 Sim 8' - 0" No. D B 3 C A 4 DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) 6' - 0" 2 2 2 2 2 2 2 2 2 2 2 2 4' - 0" 3 3 3 3 3 3 3 3 3 3 3 3 NOTES 2' - 0" HM HM HM HM HM HM HM HM HM HM HM HM HM HM HEAD 3" 1 1 S1 1 1 1 1 1 1 1 S2 2 1 1 JAMB ARCHITECTURE 0' - 6" 2" 3 2 1 4 4 7 2 5 5 2 1 6 4 5 FRAME FINISH 0' - 6" 0' - 6" 1" MATL 0' - 6" REF. SCHED. WD WD AL WD WD WD WD WD WD WD AL WD WD WD TYPE EQ REF. SCHED. 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" HARDWARE SET NO. EQ 0' - 6" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" FIRE RATING EQ 0' - 6" REF. SCHED. 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 2' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" FINISH REF. SCHED. A C C A A E A A A A CC AA A A MATL EQ 0' - 2" 0' - 2" 125 126 128 129 136 137 138 140 141A 141B 142A 142B 144 145 DOOR THICKNESS REF. SCHED. REF. SCHED. HEIGHT 0' - 2" WIDTH 0' - 2" REF. SCHED. TYPE 0' - 2" 0' - 6" DOOR SCHEDULE DOOR NO. REF. SCHED. REF. SCHED. 0' - 6" 0' - 2" REF. SCHED. PLC REF. SCHED. 4" REF. SCHED. Description 1 2 Date Addendum 001 Addendum 002 12/29/2014 01/05/2015 REVISIONS FRAME TYPE 1 HOLLOW METAL FRAME TYPICAL FOR SINGLE LEAF DOOR D FRAME ELEVATIONS 1/2" = 1'-0" 0' - 2" F DOOR TYPE C REF. SCHED. FOR MATERIAL TYPICAL DOOR DOOR TYPE AA REF. SCHED. FOR MATERIAL TYPICAL DOOR DOOR TYPE CC REF. SCHED. FOR MATERIAL TYPICAL DOOR FOR MAX VISUAL DOOR ELEVATIONS 1/2" = 1'-0" 12' - 2" 0' - 2" 6' - 0" 0' - 2" 0' - 2" REF. SCHED. 0' - 2" 2' - 9" 0' - 2" 2' - 11" 0' - 2" 2' - 9" 0' - 2" 3' - 10" INTERIOR HOLLOW METAL DOOR FRAME 2' - 10" 0' - 1" FINISH FLOOR Consultants SCHED. DOOR 2' - 10" 0' - 2" EXTERIOR REF. SCHED. MTL STUD BOX HEADER ALUM. STOREFRONT DOOR SYSTEM 0' - 2" MTL STUD FRAMING REF. SCHED. 5/8" GYP. BD. 3' - 10" TO HINGE SIDE, UNLESS OTHERWISE INDICATED INSUL. WHERE OCCURS 8' - 0" FACE OF GYP, COUNTER, OR OTHER PERPENDICULAR OBJECT 0' - 8" 3' - 0" 0' - 8" 0' - 2" 0' - 2" GYP. BD. BOTH SIDES 0' 0" 1/2" = 1' DOOR TYPE A REF. SCHED. FOR MATERIAL TYPICAL DOOR FRAME TYPE 2 HOLLOW METAL FRAME TYPICAL FOR DOUBLE LEAF DOOR 0' - 2" 0' - 2" 1. 2. 3. 4. REFERENCE THE STOREFRONT ELEVATIONS (THIS SHEET) FOR PROPER STOREFRONT SYSTEM FRAME RELOCATE & INSTALL EXISTING HARDWARE FROM INDICATED REMOVED DOORS ON THE DEMILTION PLAN FOR DOORS NOTED A,B,C,&D USE ¼” TEMPERED CLEAR GLASS ALL INTERIOR LITES. USE 1" INSULATED CLEAR TEMPERED LOW EMISSIVITY GLAZING ON ALL EXTERIOR LITES. PANIC HARDWARE TEMPORARILY INSTALL HOLLOW METAL DOORS FOR THE MAJORITY OF CONSTRUCTION, INSTALL SCHEDULED DOOR AT END OF PROJECT 1' - 0" S 0. 1' - 0" DOOR SCHEDULE NOTES 5/8" GYP. BD. 3 2 INT DOOR HEAD JAMB 3" = 1'-0" FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO EXISTING TRIM PIECE S1 STOREFRONT 2 1/2" = 1'-0" 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL MIRROFLEX-MF1, TYPICAL MIRROFLEX-MF1, TYPICAL 7 Sim Sim 9 AI600 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL AI600 FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL 10 0° Sim 7 MIRROR-M1 MIRROFLEX-MF1, TYPICAL FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO END OF WALL AI600 1' - 4"1' - 1" 3' - 0" 2' - 11" 1' - 5" 80 ° 82 ° 0' - 2" 0' - 4" TO EXISTING CEILING 0' - 4" 1' - 3"1' - 0" 3' - 1" 1' - 7" 1' - 11" 2' - 10" 2' - 11" 1' - 3" 3' - 3" 1' - 3" 1' - 8" 2' - 6" 3' - 2" 0' - 9" 1' - 6" STAIRS DOWN TO CASINO FLOOR MIRROFLEX-MF1 8 LOBBY 145 SOUTH 1/4" = 1'-0" W LOBBY 135 NORTH 1/4" = 1'-0" 2' - 1" 2' - 1" 0' - 9" WINDOW TYPE A ALUMINUM FRAME 2-WAY GLASS WINDOW TYPE B ALUMINUM FRAME 2-WAY GLASS WINDOW ELEVATIONS 1/2" = 1'-0" 4" 2 NEW WORK RM. FUTURE SPA 143 144 NEW OFFICE EXISTING HANDRAIL TO REMAIN STAIRS DOWN TO CASINO FLOOR CA1 82 ° 136 134.2 134.1 EXIST. FLOOR TO REMAIN EXIST. FLOOR TO REMAIN STF2 10' - 4" 5' - 6" 1 WC1/WC8 STF1 STF3-WATER JET CUT EX LOBBY 31' - 3" STF1 STF2 3' - 8" 9' - 9" STF2 STF1 STF2 EXISTING FLOOR TO REMAIN USE ¼” TEMPERED CLEAR GLASS ALL INTERIOR LITES. USE 1" INSULATED CLEAR TEMPERED LOW EMISSIVITY GLAZING ON ALL EXTERIOR LITES. USE MIRRORED GLASS REF. INTERIORS. MF1 TO CLG BASE-STF2 2' - 9" 3° 1 CA2 STF2 12° FLOORING LEGEND STF1 27° 2' - 0" 7' - 11" STF2 VIP CHECKIN 140 MF1 TO CLG BASE-STF2 EXIST. MECH MECH SC 139 137 COPIER ROOM 141 1 1 EX. STOR. FRONT DESK 138 CA2 STF1 STF2 STF3 EXIST. TO REMAIN 1 STF3-WATER JET CUT STF1 145 CA2 MF1 TO CLGCONTINUE TO END OF RAMP WALL, BOTH SIDES AND ENDS BASE-STF2 PROJECT NO. 01-1305 v.1.4_noSeal SHEET TITLE: INTERIOR FINISH FLOOR PLAN 1/8" = 1'-0" DRAWN BY: 2 STF2 MF1 TO CLG BASE-STF2 MF1 TO CLG MF1 TO CEILING BASE-STF2 CA1/CA2 *REFER TO FINISH LEGEND 1 Key Plan 2' - 0" CORR 26' - 11" N WITHIN THIS PERIMETER CIRCLE-EXISTING FLOOR TO REMAIN STF2 STF3-WATER JET CUT 146 MF1 TO CEILING BASE-STF2 STF1 EXIST. FLOOR TO REMAIN WC1/WC8 28' - 10" OVERALL CASINO STF1 135 27' - 3" HOTEL LOBBY AREA OF WORK 1 EXISTING FLOOR TO REMAIN 22' - 4" 12/03/2014 Seal STF2 WC1/WC8 STF1 STF3-WATER JET CUT WINDOW SCHEDULE NOTES 3. 134 147 5' - 3" 1. 2. 129 STF1 82 ° STF1 " 2' - 4 TEMP DESK LOBBY 135 NW - STAIRS DOWN TO CASINO FLOOR 1/4" = 1'-0" 2 ELV-2 40' - 6" 1' - 8" 1' - 4" EX. VEST ELV-3 40' - 6" 6" 40' - 5' - 2" EX. VEST STF1 STF2 STF2 2' - 3" EX. VEST. EX. ELEV ° 55 CA1 TEMP COPIER EX. STOR. 5° 11 ° 97 10 126 CA1 EX. ELEV EXIST. FLOOR TO REMAIN STF2 125 EXIST. FLOOR TO REMAIN 42' 10" 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL EXISTING JEWELRY STORE WC1/WC8 9' - 2" EXISTING CEILING EXIST. FLOOR TO REMAIN 133 1' - 5" 124 128 24' - 0" 123 130 0' 142 EX. FIRE ELV-1 EX. EXIST. FLOOR TO REMAIN ELEC. 1/8" = 1' FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN EX. MECH EX. ELEV 1" FUTURE SPA LOBBY EX. ELEV. LOBBY WC1/WC8 122 12' - 4" MIRROFLEX-MF1, TYPICAL WC1/WC8 0" EX. DATA 1 NEW STEP DOWN TRANSITION MATCH EXISTING LOCATION EX. STRS 8' - 0" EXIST. FLOOR TO REMAIN 16' - 0" EXISTING CONCRETE 2 3" 1' - 5" 98 ° 2" 4' - 0" ° 87 0' - 5" ° 87 9 ° 80 1' - 2" 82 ° WAINSCOTT-WC8 CLAD IN MF1 4° 10 ° 83 EXISITNG HANDRAIL TO REMAIN 2' - 7" ° 93 98 ° ° 83 ° 84 90 ° 2' - 6" 10 0° 100% CONSTRUCTION DOCUMENTS FRYE REGLET "J" MOLD AT EDGE OF WALL-PATTERN CONTINUE TO EXISTING TRIM PIECE 1' - 3" AI600 32' - 0" 1/2", "SNAP IN REVEALS" FROM FRYE REGLET-TYPICAL 1' - 4" STOREFRONT 1 1/2" = 1'-0" 8' - 8" Sim 7 S2 INT DOOR HEAD 3" = 1'-0" 0' - 4" EXT STOREFRONT DOOR SILL 3" = 1'-0" REF. SCHED. CHECKED BY: ISSUE DATE: INTERIOR FLR PLAN, DOORS & WINDOWS Author Checker 12/03/2014 AI601 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. HOLLOW METAL DOOR FRAME CHEROKEE NATION ENTERTAINMENT, LLC 777 W. CHEROKEE ST. CATOOSA, OK 74015 3 5/8" MTL STUD FRAMING @ 16" O.C. 128 HARD ROCK LOBBY RENOVATION CONCRETE SLAB 142A 0' - 2" SCHED. DOOR 0' - 2" INSUL. WHERE OCCURS 8' - 8" 4 BACKER ROD & SEALANT PLC ARCHITECTURE DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) No. Description 2 Date ADDENDUM #2 01-05-15 LIGHTING ZONING PLAN GENERAL NOTES A. INTERFACE THE PROGRAMMING AND CONTROL OF THE FOLLOWING LIGHTING ZONES WITH THE EXISTING MODERO X SERIES LIGHTING CONTROL SYSTEM. PROVIDE ALL PROGRAMMING AND ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION REVISIONS ZONE 1: CEILING LIGHTS - TYPE 'G1' FIXTURES ZONE 2: CEILING LIGHTS - TYPE 'H' FIXTURES ZONE 3: COLUMN LIGHTING - TYPE 'G1' FIXTURES ZONE 4: CHECK-IN DESK UNDER COUNTER LIGHTING - TYPE 'G1' FIXTURES ZONE 3 ZONE 5: CHECK-IN DESK BACK LIGHTING - TYPE 'H4' FIXTURES LOCAL LIGHTING CONTROLS CERTIFICATE OF AUTHORIZATION 5338 RENEWAL DATE: 6/30/2015 ZONE 1 HP ENGINEERING INC. 1836 SOUTH BALTIMORE AVENUE SUITE B TULSA, OKLAHOMA 74119 (539) 664-4618 ZONE 2 B. PROVIDE 7" AUX AV TOUCH PANELS AT TWO LOCATIONS FOR CONTROLLING THE LED ZONE LIGHTS. REFER E301: SYSTEM PLAN AND KEYNOTES FOR EXACT LOCATION AND DETAILS. ZONE 4 Consultants ZONE 5 LOCAL LIGHTING CONTROLS LIGHTING PLAN GENERAL NOTES B. WHERE TYPE 'H' FIXTURES ARE SHOWN IN THE DRAWINGS (TYPE H1/H2/H3/H4), ADJUST THE LENGTHS AND USE CONNECTIONS AS NEEDED TO FIT PROPERLY IN THE SLOTS AS PER MANUFACTURER'S RECOMMENDATION. ALL TYPE 'H' FIXTURES ARE NOT TAGGED TO AVOIDING OVERCROWDING IN THE SHEET. X1 X1 C1 C1 1. 2. 3. H4 5. 6. 7. 8. 9. B1 B1 A1 LH1B -9 A1 B1 B1 LH1B -7 B1 LH1B -8 TH TH TH LH1B -30 TH TH TH TH T1 H4 X1 H4 C1 H4 H2 C1 C1 9 LH1B -26 C1 H4 H4 H4 H4 H4 H2 H3 LH1B -33 H4 H4 H4 C1 H4 H4 H4 H4 H4 H1 H2 H3 H4 H4 H4 H4 H4 H4 H4 H1 H4 H1 H4 LH1B -31 H4 H4 H4 H4 H4 H2 H4 H4 H4 H2 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H2 H4 C1 H3 H4 H4 H4 C1 H4 H4 H4 H4 H4 H4 H4 H3 H2 H4 C1 H4 H4 H4 C1 H4 LH1B -24 C1 C1 C1 H3 H4 H3 H4 H3 H4 H4 H4 7 R4 D1 D1 R4 C1 LH1B -29 R4 D1 R4 D1 D1 D1 R1 R2 AREA OF WORK C1 H2 H4 H2 5 H4 C1 H4 C1 D1 R4 D1 R2 H4 H4 H4 H2 C1 C1 H4 H4 H4 H4 H4 F1 LH1B -19 H4 C1 H4 H4 H4 F1 D1 H2 H4 F1 F1 D1 H4 H4 F1 D1 D1 LH1B -17 2 H2 G1 LH1B -27 H4 H4 H3 LH1B -15 C1 H4 H4 H4 LH1B -2 H4 H4 D1 H1 H4 H3 H4 C1 H4 H2 H4 H4 H4 H4 A1 1 H4 H4 H4 Key Plan X1 H4 3 C1 C1 C1 D1 F1 D1 F1 D1 F1 D1 9 F1 F1 D1 F1 D1 D1 6 D1 D1 D1 D1 D1 D1 4 E402 LH1B -3 F1 4 D1 S1 H4 H4 H4 H4 H4 H4 A1 A1 H4 H2 H4 LH1B R4 H4 C1 X1 H4 H4 C1 LH1B -2 H2 H4 H4 LH1B -12 LH1B -13 H2 LH1B -22 H2 H4 H3 TH TH 8 T1 LH1B -2 01/05/2015 LH1B -25 LH1B -2 H2 H4 H4 H4 H4 H4 H4 H4 H3 H4 H4 H4 H4 TH TH TH TH TH H3 TH H1TH TH TH TH TH TH TH TH H4 TH TH H4 H4 C1 H4 TH H4 H4 H4 H1 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 C1 H4 H4 H4 H4 H4 H3 H4 H4 TH TH TH TH TH TH TH TH T1 T1 TH TH T1 TH TH C1 T1 T1 T1 C1 X1 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 C1 H4 H4 H4 H4 H3 H4 H3 T1 TH TH T1 H2 LH1B -28 H4 T1 T1 H4 H3 H1 H4 LH1B -10 TH H3 H4 LH1B -11 TH T1 T1 H4 TH T1 T1 LH1B -1 H3 T1 Seal H4 H4 C1 LH1B -2 TH TH TH TH TH TH A1 A1 LH1B -2 A1 TH A1 B1 T1 TH H3 H4 H4 H4 H4 TH H4 T1 TH H4 H4 TH H4 T1 TH H1 H4 H4 H4 H4 H4 H4 B1 B1 H4 TH A1 H4 N 4. INSTALL TYPE 'G1' FIXTURE' ALONG THE ENTIRE LENGTH OF THE CURVED CEILING SOFFIT ON BOTH SIDES. INSTALL 10199 RGB CONTROLLER, REMOTE ELECTRONIC CLASS 2 TRANSFORMER AND ANY OTHER COMPONENTS REQUIRED FOR THE PROPER LIGHTING OF THE FIXTURE. LOCATE THE TRANSFORMER ABOVE CEILING AND PROVIDE CEILING ACCESS PANEL FOR MAINTENANCE. INSTALL CLASS 2 TRANSFORMER 120V AC INPUT, 24V DC OUTPUT FOR EVERY 20'(MAXIMUM) OF LED TAPE LIGHT TYPE 'G' FIXTURE. TYPICAL FOR JUNCTION BOXES AT THE SIDES OF THE CURVED SOFFIT. UNDER-DESK LIGHTING: INSTALL CLASS 2 TRANSFORMER 120V AC INPUT, 24V DC OUTPUT FOR EVERY 20' (MAXIMUM) OF LED TAPE LIGHT(TYPE 'G1' FIXTURE) UNDER THE CHECK IN DESK IN THE FRONT. TYPICAL FOR THE THREE JUNCTION BOXES UNDER THE FRONT DESK. REFER TO DETAIL SHEET E402:2, SHEET E402:4 AND E402: LUMINAIRE SCHEDULE . REFER TO DETAILS E402: 2 AND E402:3 FOR BACK LIGHTING FOR CHECK-IN DESKS. COLUMN LIGHTING TYPICAL FOR JUNCTION BOXES AT THE SIDES OF THE COLUMN NEAR CEILING: INSTALL TYPE 'G1' FIXTURE ON THE SIDES OF THE COLUMN PER ARCHITECT'S DETAIL. INSTALL CLASS 2 TRANSFORMER 120V AC INPUT, 24V DC OUTPUT ON EACH SIDE OF THE COLUMN. CIRCUIT AND CONTROL ALL COLUMN LIGHTING TOGETHER(LH1B-2). THERE SHALL BE TWO SWITCHES AT THIS LOCATION. ONE SWITCH SHALL CONTROL THE DECORATIVE PENDANT LIGHTS (TYPE 'F1') AND THE OTHER SWITCH SHALL CONTROL THE RECESSED DOWNLIGHTS(TYPE 'D1'). THERE SHALL BE TWO SWITCHES IN THIS ROOM. ONE SWITCH SHALL CONTROL THE LINEAR RECESSED STRIP LIGHTS(TYPE 'R1') AND THE OTHER SHALL CONTROL THE RECESSED DOWNLIGHTS (TYPE 'D1'). TYPE 'R1' FIXTURE SHALL BE CONTINUOUS RECESSED STRIP FIXTURE ALONG THE CEILNG AND EXTENDING DOWN THROUGH THE WALL TOUCHING THE FLOOR. REFER TO DETAIL E402: 5 FOR VIP CHECK-IN ROOM LIGHTING. PROVIDE SWITCHED BREAKERS IN PANEL 'LH1B' AND CIRCUIT TRACK LIGHTING TO IT. TYPICAL FOR ALL NEW TRACK LIGHTING. THREE WAY SWITCHES AT THESE TWO LOCATIONS CONTROL THE CAN LIGHTS(TYPE 'C1') IN THE CORRIDOR H4 X1 C1 LIGHTING PLAN KEYNOTES LH1B -21 H1 H3 H4 H4 H4 H2 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. INTERFACE THE PROGRAMMING AND CONTROL OF DIFFERENT LIGHTING ZONES WITH THE EXISTING MODERO X SERIES LIGHTING CONTROL SYSTEM. REFER TO LIGHTING ZONING PLAN IN THIS SHEET FOR ZONE LIGHTING. D1 LH1B -14 3 E402 100% CONSTRUCTION DOCUMENTS A. HARD ROCK CASINO 777 W. CHEROKEE ST. CATOOSA, OK 74015 HOTEL LOBBY RENOVATION 2 FIRST FLOOR LIGHTING - ZONING PLAN 1/8" = 1'-0" PROJECT NO. 01-1305 v.1.4_noSeal 1 FIRST FLOOR LIGHTING PLAN 1/8" = 1'-0" LIGHTING PLANS SHEET TITLE: 2 DRAWN BY: RG BP 01/05/2015 CHECKED BY: ISSUE DATE: E201 PLC ARCHITECTURE DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) No. Description 2 Date ADDENDUM #2 01-05-15 REVISIONS LIGHTING PLAN DEMO NOTES REMOVE ALL EXISTING LIGHTING ASSOCIATED WITH THE REMOVAL OF THE EXISTING BAR, RECEPTION DESK, DECORATIVE COLUMNS, CEILING AND WALLS IN THE LOBBY AND RETURN TO OWNER. CR 1. CERTIFICATE OF AUTHORIZATION 5338 RENEWAL DATE: 6/30/2015 HP ENGINEERING INC. 1836 SOUTH BALTIMORE AVENUE SUITE B TULSA, OKLAHOMA 74119 (539) 664-4618 HOTEL LOBBY RENOVATION FIRST FLOOR DEMO LIGHTING PLAN 1/8" = 1'-0" CR 2 HARD ROCK CASINO 777 W. CHEROKEE ST. CATOOSA, OK 74015 Consultants M M DN EH EL TXH1 SYSTEMS PLAN GENERAL NOTES S THX2 A. ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL OWNER SUPPLIED A/V AND LOW VOLTAGE EQUIPMENT. PROVIDE RACEWAYS AND POWER OUTLETS WHERE SHOWN. PROVIDE A COMPLETE INSTALLATION TO ACCOMODATE OWNER EQUIPMENT. This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. CR 23042 TV LP DN CR B. OWNER WILL PROVIDE THE LOW VOLTAGE MATERIALS. CONTRACTOR SHALL PROVIDE A MATERIAL LIST TO THE OWNER(QUANTITIES ETC) BASED ON THESE DRAWINGS. Robert Brandon Pinkerton G I NEER LH1A EN L I C E NS E D S S I ON A OFE L PR OK L A H OM A CR CA5338(PE) C. CONFIRM THE EXACT LOCATIONS OF THE LOW VOLTAGE DEVICES WITH THE A/V CONTRACTOR PRIOR TO ROUGH-IN. S Seal 01/05/2015 D. OWNER TO FURNISH STRUCTURAL CABLING. CONTRACTOR INSTALLED. AREA OF WORK S S E. OWNER TO FURNISH WIFI EQUIPMENT. S S S SYSTEMS PLAN KEYNOTES S N S 1 Key Plan 1 S S S S S S S CR LH1B 1 S TP CR TP S S S S DN SD CR M 2 TXH6 DN 2 DN 100% CONSTRUCTION DOCUMENTS S 2. PROVIDE TWO(2) CAT6 CABLE DROPS FOR ACCESS CONTROL POINTS. PROVIDE DOUBLE GANG BOX WITH SINGLE MUD RING FOR 7" AUX AV TOUCH PANELS AT THIS LOCATION FOR CONTROLLING THE LED LIGHTS. ROUTE TWO 1"C UPTO ACCESSIBLE CEILING SPACE. MOUNT AT +54" AFF. S 1. PROJECT NO. 01-1305 1 FIRST FLOOR SYSTEMS PLAN 1/8" = 1'-0" v.1.4_noSeal SYSTEMS PLAN SHEET TITLE: 2 DRAWN BY: RG BP 01/05/2015 CHECKED BY: ISSUE DATE: E301 PLC ARCHITECTURE DESIGN 2 No. Description 2 Branch Panel: LH1A Location: ELECTRICAL 121 Supply From: Mounting: Surface Enclosure: Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) Date ADDENDUM #2 01-05-15 Branch Panel: LH1B A.I.C. Rating: Mains Type: Mains Rating: 250 A Location: EXIST. MECH 139 Supply From: Mounting: Surface Enclosure: Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: Mains Rating: 250 A Notes: Notes: REVISIONS CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 Circuit Description Spare Spare Temp copier room power Copier room 141 power Spare Check-in desk power Check-in desk power Data room 122 power Lobby power New office 125 power Power video wall Check-in desk power Spare Spare Check-in desk power VIP Check in power Data room 122 power Spare Spare New work room 126 power Temporary check in desk power Temporary check in desk power Temporary check in desk power Trip 0A 0A 20 A 20 A -20 A 20 A 20 A 20 A 20 A 20 A 20 A 0A 0A 20 A 20 A 20 A 0A 0A 20 A 20 A 20 A 20 A Poles A 1 0 VA 0 VA 1 1 1 900... 0 VA -1 1 1080... 0 VA 1 1 1 900... 0 VA 1 1 1 0 VA 0 VA 1 1 1 1080... 0 VA 1 1 1 0 VA 0 VA 1 1 1 1080... 0 VA 1 B 0 VA C 1080... 900 VA 0 VA 0 VA 0 VA 1260... 360 VA 0 VA 0 VA 900 VA 0 VA 1500... 0 VA 1080... 0 VA 0 VA 1080... 360 VA 0 VA 0 VA 1080... 1260... 0 VA 0 VA 0 VA 540 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 1 1 1 1 1 1 1 1 1 1 1 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA Circuit Description Spare Temporary check in desk power Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0A Trip -20 A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0 VA 0 VA Spare Poles -1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Total Load: Total Amps: 5 kVA 42 A 5 kVA 43 A 0 VA 0 VA 6 kVA 53 A 1 1 1 1 0A 0A 0A 0A Spare Spare Spare Spare CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Circuit Description Junction box for ceiling(type G) lighting Junction box for front desk(type G) lighting Spare Trac lighting switched breaker Trac lighting switched breaker Trac lighting switched breaker Trac lighting switched breaker Rotunda Track lighting switched breaker Rotunda Track lighting switched breaker VIP checkin room and other lighting new Lighting Check in desk back-type H4 Lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Trip 20 A 20 A -20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Poles 1 1 -1 1 1 1 1 1 1 1 1 1 1 1 1 1 Spare 0A 1 Spare 0A 1 Spare 0A 1 Total Load: Total Amps: A 1120... 600 VA B C 240 VA 1252... 0 VA 1252... 1511... 1511... 906 VA 906 VA 1209... 911... 1209... 1051... 1252... 0 VA 1566... 0 VA 1500... 1632... 1758... 952 VA 1632... 1598... 1649... 1836... 1785... 1496... 1683... 1768... 1666... 0 VA 1717... 0 VA Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 0A 0A 20 A 20 A 20 A 20 A 20 A 20 A 0A 0A Circuit Description Junction box for column (type G) lighting Temp Track lighting Temp track lighting Trac lighting switched breaker Trac lighting switched breaker Trac lighting switched breaker check in desk-type F1 lighting Spare Spare Check in desk back - type H4 Lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Type H ceiling lighting Spare Spare 0 VA 0 VA 15 kVA 128 A 12 kVA 103 A 0 VA 12 kVA 97 A CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CERTIFICATE OF AUTHORIZATION 5338 RENEWAL DATE: 6/30/2015 HP ENGINEERING INC. 1836 SOUTH BALTIMORE AVENUE SUITE B TULSA, OKLAHOMA 74119 (539) 664-4618 Consultants Legend: Load Classification Lighting Other Power Lighting - Dwelling Unit Connected Load 27155 VA 0 VA 10060 VA 3531 VA Demand Factor 125.00% 0.00% 100.00% 90.23% Estimated Demand 33944 VA 0 VA 10060 VA 3186 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 41 kVA 47 kVA 113 A 131 A Notes: THERE ARE EXISTING LOADS CIRCUITED TO THIS PANEL, MARKED AS 'SPARE' -THEIR LOADS ARE NOT SHOWN IN THE SCHEDULES. Connected Load 1500 VA 14940 VA Demand Factor 100.00% 83.47% Estimated Demand 1500 VA 12470 VA HOTEL LOBBY RENOVATION Load Classification Power Receptacle Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: HARD ROCK CASINO 777 W. CHEROKEE ST. CATOOSA, OK 74015 Legend: 16 kVA 14 kVA 46 A 39 A Notes: THERE ARE EXISTING LOADS CIRCUITED TO THIS PANEL, MARKED AS 'SPARE' - THEIR LOADS ARE NOT SHOWN IN THE SCHEDULES. This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. G I NE ER Robert Brandon Pinkerton EN L I C ENS ED S S I ON A O FE L PR 23042 OK L A H OM A CA5338(PE) Seal 01/05/2015 AREA OF WORK N 100% CONSTRUCTION DOCUMENTS Key Plan PROJECT NO. 01-1305 v.1.4_noSeal ELECTRICAL SCHEDULES SHEET TITLE: DRAWN BY: RG BP 01/05/2015 CHECKED BY: ISSUE DATE: E401 PLC ARCHITECTURE LUMINAIRE SCHEDULE Type Mark Manufacturer Model Lamp COOPER LIGHTING METALUX COOPER LIGHTING METALUX COOPER LIGHTING PORTFOLIO COOPER RSA LIGHTING, COMBO LIGHT LV SERIES TECHLIGHTING KICHLER LIGHTING 2GC8IC UNV LAMPS SNF 232 -UNV AYC-CHAIN SET LD4A 13 D010TE ERM4A13 8 35 LI (2) 32W T8 (2) 32W T8 LED 56 VA 56 VA 22 VA LV2010IS WH PAR20 39 VA 88 VA 80 VA NOTE B,C INSIGHT LIGHTING MEDLEY Xi LED 17 VA NOTE B,C H2 2' LINEAR LED RGBW COLOR CHANGING INSIGHT LIGHTING MEDLEY Xi LED 34 VA NOTE B,C H3 3' LINEAR LED RGBW COLOR CHANGING INSIGHT LIGHTING MEDLEY Xi LED 51 VA NOTE B,C H4 4' LINEAR LED RGBW COLOR CHANGING INSIGHT LIGHTING MEDLEY Xi LED 68 VA NOTE B,C R1 1' RECESSED LED STRIP GAMMALUX G-BEAM SERIES LED 10 VA Acuity Brands Lighting Cooper Industries, Inc. 700LSSURG S LED 3000K 24V DC DRY LOCATION RGB-4 WATTS/ FT MXi 17 RGBW 100 D CES 12" TBL CDS-PK CRF MXi 17 RGBW 100 D CES 24" TBL CDS-PK CRF MXi 17 RGBW 100 D CES 36" TBL CDS-PK CRF MXi 17 RGBW 100 D CES 48" TBL CDS-PK CRF GB34RC2 1S0LED35 UNIV ZTVL N REC ASLMD WH GB34RC2 1S0LED35 UNIV ZTVL N REC ASLMD WH GB34RC2 1S0LED35 UNIV ZTVL N REC ASLMD WH ZL1N L48 5000LM L/LENS MVOLT 35K HALO L651 MB LED LED H1 2x4 LENSED TROFFER 4' NARROW STRIPLIGHT- CHAIN HUNG 4" LED RECESSED MEDIUM BEAM DOWNLIGHT RECESSED PAR20 LV TRIMLESS 1 LAMP LUMINAIRE ULTRASLIM LED LINEAR SUSPENSION TASKWORK LED TAPELIGHT COLOR CHANGING 1' LINEAR LED RGBW COLOR CHANGING LED 42 VA 75 VA Cooper Industries, Inc. Acuity Brands Lighting HALO LA805MED NF 8 30 MB EDG RED LED LED 18 VA 5 VA D1 F1 G1 R2 2' RECESSED LED STRIP GAMMALUX G-BEAM SERIES R4 4' RECESSED LED STRIP GAMMALUX G-BEAM SERIES S1 T1 TH X1 4' NARROW STRIPLIGHT-SURFACE MOUNT SINGLE CIRCUIT TRAC- USE ENDFEED CURRENT LIMITER TRACHEAD LED EDGE LIT EXIT No. Apparent Load Keynote LED 18 VA LED 28 VA NO SUBSTITUTIONS WILL BE ALLOWED FOR LIGHTING FIXTURES. B. ELECTRICAL CONTRACTOR TO ORDER LENGTHS OF THE FIXTURE BASED ON DRAWINGS AND MANUFACTURER'S INPUT. C. ORDER QUANTITY OF DATA ENABLER PRO CONTROLLERS ACCORDING TO MANUFACTURER'S RECOMMENDATION. Description 2 Date ADDENDUM #2 01-05-15 REVISIONS 2 INSTALL CONTINUOUS LED STRIP LIGHTING TYPE 'G1' FIXTURE ON FULL HEIGHT OF COVE IN THE COLUMN . STRUCTURAL COLUMN TO REFLECT THE LIGHT OUTSIDE THE COLUMN FROM BOTH SIDES CERTIFICATE OF AUTHORIZATION 5338 RENEWAL DATE: 6/30/2015 HP ENGINEERING INC. 1836 SOUTH BALTIMORE AVENUE SUITE B TULSA, OKLAHOMA 74119 (539) 664-4618 Consultants 1 A. PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) Type Comments A1 B1 C1 DESIGN COLUMN PLAN DETAIL 3" = 1'-0" 3M QUARTZ TRANSACTION COUNTER ROOF SPRING 14' - 0" T.O. STUDS 10' - 0" CONTINOUS DECORATIVE PENDANTS OF TYPE 'F1' ABOVE THE CHECK-IN DESKS. ONE PER COUNTER. DETAIL DOES NOT REPRESENT THE EXACT SHAPE OF THE FIXTURE. LH1B-19 INSTALL FOUR CONTINUOUS LED LIGHTING STRIPS OF TYPE 'H4' FIXTURE ON ENTIRE LENGTH OF THE CHECK IN DESKS. PROVIDE ACCESS PANEL FOR MAINTENANCE. CHECK IN DESK- BACK VIEW 3/16" = 1'-0" S S I ON A O FE L PR EN G I NEER Robert Brandon Pinkerton This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. 3 GROUND LEVEL 0' - 0" L I C E NS ED 2 FRONT DESK SECTION 1 1/2" = 1'-0" LH1B-20 23042 OK L A H OM A CA5338(PE) Seal 01/05/2015 AREA OF WORK N ROOF SPRING 14' - 0" RECESSED CAN LIGHTS OF TYPE 'D1' ABOVE THE CHECK-IN DESKS. ONE PER COUNTER. COORDINATE THE LOCATION WITH LOCATION OF SECURITY CAMERA. T.O. STUDS 10' - 0" CONTINOUS DECORATIVE PENDANTS OF TYPE 'F1' ABOVE THE CHECK-IN DESKS. ONE PER COUNTER. DETAIL DOES NOT REPRESENT THE EXACT SHAPE OF THE FIXTURE. INSTALL CONTINUOUS LED LIGHTING STRIPS OF TYPE 'G1' FIXTURE ON ENTIRE LENGTH OF THE CHECK IN DESKS. PROVIDE ACCESS PANEL FOR MAINTENANCE. 4 CHECK IN DESK-FRONT VIEW 3/16" = 1'-0" Key Plan J J 100% CONSTRUCTION DOCUMENTS LED BACK LIGHTING, TYPE 'H4' FIXTURE ALONG THE LENGTH OF THE COUNTER HOTEL LOBBY RENOVATION RECESSED CAN LIGHTS TYPE 'D1' ABOVE THE CHECK-IN DESKS. ONE PER COUNTER. COORDINATE THE LOCATION WITH LOCATION OF SECURITY CAMERA. HARD ROCK CASINO 777 W. CHEROKEE ST. CATOOSA, OK 74015 LED LIGHTING, TYPE 'G1' FIXTURE ACROSS THE LENGTH OF THE COUNTER J GROUND LEVEL 0' - 0" 5 VIP CHECK-IN ROOM LIGHTING PROJECT NO. 01-1305 v.1.4_noSeal ELECTRICAL SCHEDULES AND DETAILS SHEET TITLE: DRAWN BY: RG BP 01/05/2015 CHECKED BY: ISSUE DATE: E402 PLC ARCHITECTURE DESIGN PLANNING 618 East 3rd Street Tulsa, OK 74120 918.743.2724 (o) 918.743.2725 (f) No. Description 2 Date ADDENDUM #2 01-05-15 REVISIONS HVAC KEYNOTES 1 EXISTING DUCTWORK TO REMAIN. 2 EXISTING DIFFUSER AND ASSOCIATED DUCTWORK TO REMAIN. 3 CONNECT NEW DUCTWORK TO EXISTING DUCTWORK. REFER TO PLANS FOR SIZES 4 4'-0" LONG ACTIVE SUPPLY SECTION WITH FIELD FABRICATED PLENUM. 5 3--0" LONG ACTIVE SUPPLY SECTION WITH FIELD FABRICATED PLENUM. 6 PROVIDE MANUFACTURERS BLANK OFF PANEL ON INACTIVE SLOT SECTION. CERTIFICATE OF AUTHORIZATION 5338 RENEWAL DATE: 6/30/2015 HP ENGINEERING INC. 1836 SOUTH BALTIMORE AVENUE SUITE B TULSA, OKLAHOMA 74119 (539) 664-4618 1 1.5 2 3 4 5 6 6.7 7 8 8.3 8.5 9 9.5 10 11 12 13 14 Consultants W 2 12x10 T/A DUCT ABOVE CEILING V EXISTING T/A DUCT TO REMAIN EXISTING HEAT PUMP TO REMAIN EXISTING HEAT PUMP TO REMAIN EXISTING HEAT PUMP TO REMAIN A 27'-0" CONTINUOUS SLOT U EX. DATA 122 T 175 CFM 4 2 EX. MECH 123 3 2 EXISTING JEWELRY STORE 143 FUTURE SPA 144 EXISTING T/A DUCT TO REMAIN 3 1 FUTURE SPA LOBBY 142 WOMEN 119 2 150 8"ø C 3 CORR 127 200 8"ø 2 22x16 T/A DUCT ABOVE CEILING 18"x14" TEMP DESK 147 29'-4" CONTINUOUS SLOT 3 14"x14" T 18"x16" VIP CHECKIN 140 B Q 4 CONTINUOUS SLOT D 14"x14" 160 8"ø A 200 CFM 20"x14" COPIER ROOM 141 EXIST. MECH 139 P 4 N.8 S S I ON A OFE L PR T FRONT DESK 138 20"x14" 16"x16" 4' - 0" A 47'-10" 8x8 T/A DUCT ABOVE CEILING Q.2 14"x14" 210 CFM 4 KORY M. ZEHR 22834 EX. STOR. 145 OK 14"x14" 3 G I NE ER 18"x16" 14"x14" EX LOBBY 135 CORR 146 2 170 CFM 8' - 0" R 210 CFM 4 175 CFM 4 T 4 175 CFM 4 D EX. ELEV ELV-3 29'-0" CONTINUOUS SLOT A A T A 4 12"x14" 2 S 170 CFM 3 170 CFM 5 6 170 CFM T EN 175 CFM 4 6 CORR 146 170 CFM 4 A 250 10"ø 16"x14" 12"x14" EX. VEST 134.2 EX. STOR. 129 20"x14" NEW OFFICE 125 D T 22x16 T/A DUCT ABOVE CEILING 175 CFM 4 150 8"ø 2 T EXPANDED FITNESS 117 A 3 TEMP COPIER 136 EX. VEST. 134 EX. ELEV ELV-2 NEW WORK RM. 126 3 T 3 1 EX. ELEV. LOBBY 128 3 A 2 3 A D 1 2 2 250 10"ø EX. STRS 133 This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of TriArch, and is not to be used, in whole or in part, for any other project, without the written authorization of TriArch. 400 CFM EX. ELEC. 130 EX. ELEV ELV-1 HOTEL LOBBY RENOVATION 2 2 3 59'-0" CONTINUOUS SLOT 1 10"ø ELECTRICAL 121 MEN 120 EXISTING HEAT PUMP TO REMAIN 1 L A H OM A CA5338(PE) 1 1 150 8"ø A 15 3 EXISTING HEAT PUMP TO REMAIN RELOCATE EXISTING THERMOSTAT (TYPICAL) Seal 01/05/2015 N AREA OF WORK M N Key Plan 1 FIRST FLOOR HVAC 1/8" = 1'-0" 100% CONSTRUCTION DOCUMENTS SUPPORT 118 1 L I C E NS ED 1 HARD ROCK CASINO 777 W. CHEROKEE ST. CATOOSA, OK 74015 D 18"x14" 0.1 PROJECT NO. 01-1305 v.1.4_noSeal SHEET TITLE: DRAWN BY: CHECKED BY: ISSUE DATE: MECHANICAL HVAC PLAN MBW KMZ 01/05/2015 M100