Selection and application guide
Residential Standby
Power Systems
For residential generators
Read the QR
code with the
QR reader in
your mobile!
www.usa.siemens.com/generators
Contents
1
Industry Leading System Controls
2-3
Generator Features
Catalog Logic - Easy Order Selection Guide
4
Air Cooled Standby Generators*
5
Liquid Cooled Standby Generators
6
SE and ST Type Transfer Switches
7
Liquid Cooled Generator Specifications/Compatible
Transfer Switches
8-11
Generator Ready Load Center
12-13
14
Portable Generators
15-16
Manual Transfer Interlock Kits
Standby Generator Ratings / Maintenance Kits
17
Mobile Link
18
Fuel Pipe Sizing
19
5 Year
WARRANTY
ASGE Home Standby Generator 5 Year Limited Warranty
Years 1 & 2
Limited comprehensive coverage on mileage*, labor, parts
Year 3
Limited comprehensive coverage on parts
Years 4 & 5
limited comprehensive coverage on engine (short block) &
alternator (rotor and stator) parts only
*A Siemens ATS is highly recommended to be used in conjunction with the generator set. If a non-Siemens ATS is
substituted for use and directly causes damage to the generator set, no warranty coverage shall apply.
- Siemens or Generac Manufactured ATS
ii
Residential generators selection & application guide
Industry Leading System Controls
 Low Voltage Shutdown
Shuts down the generator at <60% voltage for 5 seconds to better protect home owners
appliances or connected items.
 Internal Fault Shutdown
Shuts down the generator when a
failure is detected within the Evolution
Controller for more protection and easier diagnostics.
 Battery Sentinel
Monitors the battery and charging system to indicate that the battery is trending towards failure or that it has failed.
Evolution controller for air cooled generators
Type "E" Evolution Digital LCD Controller
Functions include monitoring utility power,
triggering the automatic transfer switch,
starting and stopping the generator, exercising
the generator, and monitoring the generator
for any system faults.
 High Voltage Shutdown
Shuts down the generator at >130% rated
voltage for 200 milliseconds or >110% for 5
seconds to better protect home owner appliances or connected items.

Event Log
All generators 8-22 kW feature a full event log capable of recording 50 events.
 Smart Battery Charger
Only delivers a charge to the battery when needed. Battery charge depends on ambient air temperature.
 Voltage Regulation
With the combination into the Evolution
Controller, the voltage regulation delivers
an industry leading voltage regulation
+/- 1%.
 Product Activation
Requires each generator to be activated via website or phone before automatic function is enabled - Allows a warranty activation start point for every generator sold.
 External Common Fault Alarm
The Evolution Controller has a provision to connect to a set of contacts that will allow for a common alarm when any of
the generator shut downs occur- This will allow individuals to connect into security systems, home automation systems or simply drive a different alarm within a home or business.
 Adjustable generator start time
When utility fails, the control is factory set to delay 10 seconds prior to starting the engine. There is also the capability to change the delay time between 2-1500 seconds .
 Incorrect Wiring Error
Eliminates the potential of damaging the Evolution Controller if it is not connected properly, a warning message is displayed that must be corrected before the controller is allowed to be fully operational.
Air Cooled Evolution Controller Stack up
Orange text indicates a new feature or different way of annunciation
Display
Alarms
Dealer service features/menus
Key miscellaneous
LCD Display
LED Backlit Membrane Keypad
Time & Date
Alarm Log
Run Log
Maintenance Log & Reminders
Set Exercise via Display
Run Hour Display
Battery Condition
Quad-lingual Display (Portuguese)
Quiet Test Selection
Fuel Selection
Elimination of "Inspect" prompt
Capture of Dismissal of Maintenance
Reminder Prompt
Variable Start Up Delay between
2-1500 seconds
Generator Over Voltage
Generator Under Voltage
Underspeed/Fail to Xfer
Low Battery Voltage
High Engine Temperature
Low Oil Pressure
Overcrank
Overspeed
RPM Sensor Loss
Internal Fault
Low Fuel Pressure (QT only)
Wiring Error
External common fault alarm
Overload Warning/Cooldown
Low Battery/Battery Problem
Charger Warning
Charger Missing AC
Stepper Over Current
Fuse Problem
Radio Signal Indication
Improved Smart Battery
Charger
Charging Status
Battery Voltage
USB Port
Generator Output Voltage
Output Frequency & RPM
Utility Input Voltage
Software & Hardware Version
Boot Loader Version
Command Status
Voltage Calibration
Parameter Group
Votage Code
Maintenance Hard Reset
Edit Run Hours (controller replacement)
Maintenance Schedule
Service/Monitoring Port
Serial Number
Debug
Updateable Firmware Prompts
Brown Out Voltage
Compatible with Cellular Monitoring
Product Activation
Voltage Regulator
Exercise not set error
•Certain faults will also have an associated E-code after the general message to specifically call out what the exact problem for more exact/quick diagnosis.
Residential generators selection & application guide
1
Generator Features
Substructure
Galvannealed substructure for excellent rust protection.
Natural gas/liquid propane fuel setup
The 8 - 22 kW units ship from
the factory ready for use with
natural gas. The conversion to
propane is as simple as turning
a knob. No tools required!
Exhaust enclosure
Verify spacing with local code and inspector, prior to
installation. Typically, the generator must be placed away
from any opening in the house due to exhaust regulations
from NFPA guidelines.
Wind resistant housing
150 MPH wind resistant design on both steel and aluminum
units, ASCE 7 Standards. Electrostatically applied textured
epoxy paint for added durability.
Composite base
Air cooled units are provided with composite mounting pad.
Liquid cooled units require a concrete slab.
Oil dipstick, low oil switch, high temperature switch,
oil filter, oil drain hose
Break in periods are not required on Siemens standby
generators to initiate the warranty, but are recommended.
Generator back view
Snap-in cover plate
Easy access for remote wireless monitor. Refer to page 12 for
monitor offering.
Fuel line connection
A section of UL or AGA approved flexible fuel line is required
to protect the rigid fuel line connections against generator
vibration. 1' flexible fuel line connector is included.
2
Residential generators selection & application guide
Air filter
Prolong the life of your engine
through routine maintenance and
ensure warranty requirements
are met.
Maintenance is recommended
annually or every 200 hours.
Refer to page 12 for maintenance
kit offerings.
External breaker connections
180º swing door capability and prop rod allows full range of
motion for ease of access during installation as well as servicing
on 8 - 22 kW units.
External mainline circuit breaker
Power shutdown eliminates the need to open
the enclosure. Meets fire marshall code.
LED indicator lights
included on 8-22 kW
New
features
• Green = Generator OK
• Yellow = Maintenance
needed
(not on 8-14kW)
• Red = Contact dealer
New Brighter LED
indicator lights
Door improvement
with lip to prevent
water from leaking in.
Control panel
Evolution controller functions include
monitoring utility power, triggering the
automatic transfer switch, starting and
stopping the generator, exercising the
generator, and monitoring the generator
for any system faults. Combines the
voltage regulator, engine control board
and battery charger into one single item Brings more functionality to the generator
control for a smarter power solution
Larger battery compartment
Batteries are not included and
must be purchased separately.
The recommended battery is a
26 frame battery capable of 525550cca.
Product Activation is required on all
Evolution Controlled Models to engage
automatic transfer mode. Generator will
operate in manual mode until activation
code is entered. Easy, one-time
activation process can be completed in
shop or on-site.
Data label is located inside the
generator. Serial number is required
for generator activation.
Residential generators selection & application guide
3
Catalog Logic
Easy order selection guide
Liquid Cooled
Air Cooled
Standby Power
Generators
ASGE
SGE
SGN
kW ratingsab
Voltage
R = 120/240V, 1 x
C = 208/120V, 3 x
J = 240/120V, 3x
I = 480/277V, 3 x
8
11
16
20
22
22
25
27
30
32
36
38
45
48
60
70
80
100
130
150
Fuel
G = Natural Gas
P = Liquid Propane Vapor
B = Accepts Both
R
R
R
R
R
R, C, J
R, C, J
R, C, J
R, C, J
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
R, C, J, I
B
B
B
B
B
B
B
B
B
B
B
B
B
B
G, P
G, P
G, P
G, P
G, P
G, P
Enclosure
S = Steel
A = Aluminum
Speed
Left Blank = 3600rpm
L = 1800rpm
S
A, S
A, S
S
A
A
A, S
A
A, S
A
A, S
A
A, S
A
A, S
A
A
A
A
A
Emissions
Compliant
Optioncd
E = Catalyst
L
L
L
L
L
E
E
L
E
L
E
E
E
Future Part Numbers
Voltage
Transfer Switches
R = 120/240V, 1 x
ST=Indoor Branch Circuit
C = 208/120V, 3 x Service Disconnect
J = 240/120V, 3 x Left Blank = No
Branch
SL=Outdoor Load Shedding
Circuits
SE=Load Management*
Amp I = 480/277V, 3 x D = Yes
ST
SL
SE*
50
R
10C, 12C
100
R
16C
100
C, J, I
200
C, J, I
400
C, J, I
600
R,C, J, I
Transfer Switches
ST= Indoor Branch Circuit
SL = Outdoor Load Shedding
SM = Load Management** Amps
ST
SL
Voltage
R = 120/240V,1x
C = 208/120V, 3x
J = 240/120V, 3 x
I = 480/277V, 3 x
Service
Disconnect
Left Blank = No Branch
D = Yes
Circuits
50
R
10C, 12C
100
R
16C
100
C, J, I
200
C, J, I
400
C, J, I
600
C, J, I
800
R,C, J, I
800
C, J, I
100
R
Blank, D
100
R
Blank, D
150
R
D
150
R
D
200
R
Blank, D
200
R
Blank, D
300
R
D
300
R
D
400
R
D
400
R
D
*The prefix “SM” will be replacing the previous “SE” and “SL” prefixes for Single Phase
Transfer Switches ONLY in the Fall of 2015 - See table to the right.
SM
600** R
800** R
** Will have Outdoor Load Shedding and Load Management Capabilities
a Battery not included for units 60kW and below.
b Catalyst option available on 45, 48, and 70kW units, catalyst factory standard on 100-150kW units.
c All units 30kW and below do not fall under CA/MA emissions standards, therefore are not required to have a catalyst.
d All units 32kW and above must contain emissions catalyst in order to be installed in California/Massachusettes (part number ending with "E").
4
Residential generators selection & application guide
Air Cooled Standby Generators
8, 11, 16, 20, and 22kW
120/240V, 1 phase
Standard features
 UL 2200 Listed
 Four-cycle industrial engines provide durable,
reliable, long life
 Operate on either natural gas or propane vapora
 Composite mounting pad approved to eliminate
need to pour concrete padb
 Automatic high temperature, low oil pressure,
over speed, and over crank shut down
 Low battery voltage indicator
 Standard safety fuse
 Provided with Type "E" Evolution controller
Typical load requirementsc
Description
kW
Electric Heat per 1,000 ft.
b
General Residential
Motor Load Reference
12.0
Heat Pump Elements per 1,000 ft.b
7.0
Dryer
5.5
Running Load
Description
hp
Running kW
Amps at 120v 1ø
Amps at 1240v 1ø
Refrigerator, sump pump, furnace, garage opener
0.5
0.5
4.9
2.5
Hot Tub
5.0
Range Oven
5.0
Freezer, washer, septic grinder
0.75
0.75
7.4
3.7
Hot Water Heater
4.5
General 1hp
1
1
9.8
4.9
Stove Top Burner
1.5
Well & septic lift pump
2
2
19.6
9.8
General Receptacles per 1,000 ft.b
1.0
Dishwasher
1.5
Blow Dryer
1.3
AC (per ton)
1.0
Microwave
1.0
Toasters
Lighting per 1,000 ft.
b
Starting Load
Starting kW
LR Amps at 120v 1ø
LR Amps at 240v 1ø
Refrigerator, sump pump, furnace, garage opener
0.5
1.5
25
13
Freezer, washer, septic grinder
0.75
2.3
38
19
1.0
General 1hp
1
3
50
25
0.8
Well & septic lift pump
2
6
100
50
Catalog Numbera
kW Ratingc
Enclosure Type
Engine Size
Weight (lbs.)
ASGE008RBS
8
Steel
410CC
360
GENMKIT19
ASGE011RBS
11
Steel
530CC
448
GENMKIT20
ASGE011RBA
11
Aluminum
530CC
428
GENMKIT20
ASGE016RBA
16
Aluminum
992CC
448
ASGE016RBS
16
Steel
992CC
513
GENMKIT21
ASGE020RBS
20
Steel
999CC
516
GENMKIT22
ASGE022RBA
22
Aluminum
999CC
526
GENMKIT22
Dimensions (in.)
48 x 25 x 29
Maintenance Kits
GENMKIT21
aAll units ship ready for use with natural gas, minor adjustments required for liquid propane vapor use.
bCheck local code requirements.
c Battery not included with air cooled models 8-22kw. Refer to page 12 for 26R battery.
Residential generators selection & application guide
5
Liquid Cooled Generators
1800, 2300, and 3600 RPM, 1Phase and 3 Phase
Standard features
 UL 2200 Listed
 Meets EPA Emission Regulations (units 45kW and above must have emissions catalyst to be used in CA/MA)
 Operate on either natural gas or propane vapor
 Automatic high temperature, low coolant, low oil pressure, and over speed shutdown
 Automatic voltage regulator with over voltage protection
 Isochronous Electronic Governor
 Safety fuse included
 Smart Battery Charger
 Quiet run weekly self test
 Provided with type "E" evolution controller (8-60kW units) or type "N" Nexus controller (70-150kW)
 Compatible with "SE", "SL", and future "SM" type automatic transfer switches
Air Cooled
Standby Power
Generators
ASGE
Liquid Cooled
SGE
SGN
kW ratingscd
Voltage
R=120/240v, 1 phase
C=208/120v, 3 phase
J=240/120v, 3 phase
I=480/277v, 3 phase
Fuel
G=Natural Gas
P=Liquid Propane
Vapor B=Accepts Both
Enclosure
S=Steel
A=Aluminum
8
R
B
S
11
R
B
A
16
R
B
A, S
20
R
B
S
22
R
B
A
22
R, C, J
B
A
25
R, C, J
B
S
27
R, C, J
B
A
30
R, C, J
B
A, S
32
R, C, J, I
B
A
36
R, C, J, I
B
A, S
38
R, C, J, I
B
A
45
R, C, J, I
B
A, S
48
R, C, J, I
B
A
60
R, C, J, I
G, P
A, S
Speed
Left Blank = 3600rpm
L=1800rpm
L*
L*
L*
L*
E
L*
E
L*
E
L*
E
70
R, C, J, I
G, P
A
80
R, C, J, I
G, P
A
100
R, C, J, I
G, P
A
130
R, C, J, I
G, P
A
E
150
R, C, J, I
G, P
A
E
a All units 38kW and below do not fall under CA/MA emissions standards, therefore are not required to have a catalyst
b All units 45kW and above must contain emissions catalyst to be installed in California/Massachusettes (part number ending with “E”)
c Battery not included for units 60kW and below
d Catalyst option available on 45, 48, and 70kW units, catalyst factory standard on 100-150kW units
* Denotes speed of 2300RPM
6
Emissions
Compliant
Optionab
E=Catalyst
Residential generators selection & application guide
Transfer Switches
SE Type transfer switches
Transfer switches provide the mechanism for transferring power between utility and generator service. Engineered with Digital Power
Management (DPM) technology. 100-400A single phase SE Type transfer switches have the ability to cycle on and off two air conditioners without adding additional components, allowing for a smaller generator to cover more circuits than when paired with a standard transfer switch.
Features and ratings
 100-400A
 Outdoor NEMA 3R aluminum enclosure
 Open transition
 Service rated and non-service rated
 Cover more circuits with a smaller generator
 Compatible with Evolution and NEXUS controllers
 Cover every circuit when paired with a higher kW generator
 Add additional PMM modules (6186) and manage up to four more large loads on single phase SE type transfer switches
Catalog No.*
Future Catalog No.a
SE100R
SM100R
SE100RD
SM100RD
SE150RD
SM150RD
SE200R
SM200R
SE200RD
SM200RD
SE300RD
SM300RD
SE400R
SM400R
SE400RD
SM400RD
Amp
Branch Circuits
KA Rating (in Amps)
100
150
10,000
200
300
22,000
400
Weight (lbs.)
Dimensions (in.)
Enclosure Type
20
20 x 14.6 x 7.09
Aluminum
23
21 x 14.6 x 7.09
Aluminum
39
30 x 13.5 x 6.3
Aluminum
20
20 x 14.6 x 7.09
Aluminum
39
30 x 13.5 x 6.3
Aluminum
140
48 x 21.82 x 10.06
Aluminum
133
36 x 24 x 10.6
Aluminum
140
48 x 21.82 x 10.06
Aluminum
a Denotes new parts launching Fall 2015.
* kW rating is from 8 to 20kW on each switch listed/NEMA 3 rating for each.
"ST" Type transfer switches*
"ST" type transfer switches are compatible with the Evolution and NEXUS controllers. The controller senses power outages and initiates the
transfer of power to the generator via the automatic transfer switch.
Features and ratings
 30 ft. pre-wired conduit for connecting the transfer switch to the external connection box
 2 ft. pre-wired conduit for moving circuits from the main panel to the transfer switch
 Pre-wired external connection box with a weatherproof conduit for generator connections
 Compatible with Evolution and NEXUS controllers
 Electrically operated, mechanically contacts for fast, positive connections
 Rated for all classes of load,100% equipment rated, both inductive and resistive
 160 millisecond transfer time
 Open transition
 50 amps = 10 & 12 circuit, single coil design, flush mountable  Express install kit included
 100 amps = 14 & 16 circuit, dual coil design
 Main contacts are silver plated or silver alloy to resist welding and sticking
 Suitable for use only on air cooled products (8–17 kW)
Catalog No.
ST050R10C
ST050R12C
ST100R16C
Amp
50
100
kW rating
Branch circuits
8
10
11
12
17
16
KA rating (Amp)
Wt.
(lbs.)
57
10,000
61
68
Dimensions (in.)
22.5 x 15.4 x 3.8
29.25 x 12.5 x 7
NEMA rating
Enclosure
1
ST
1
ST
1
ST
*Disconnect included
SMD models
(service rated)
SM or SE models
Residential generators selection & application guide
7
Liquid Cooled Generator Specifications/
Compatible Transfer Switches
120/240V Single-Phase
Catalog No.
kW
Rating
Fuel
Type
Enclosure
Engine Size
(Liters)
Speed
(RPM)
Amp
Output
Weight (lbs.)
Dimensions (in.)
SGE022RBAL
22
Both
Aluminum
2.4
1800
92
955
62.2 x 30.6 x 38.6
SGE025RBA
25
Both
Aluminum
1.5
3600
104
835
62.2 x 30.6 x 38.6
SGE025RBS
25
Both
Steel
1.5
3600
104
901
62.2 x 30.6 x 38.6
SGE027RBAL
27
Both
Aluminum
2.4
1800
113
955
62.2 x 30.6 x 38.6
SGE030RBA
30
Both
Aluminum
1.5
3600
125
865
62.2 x 30.6 x 38.6
SGE030RBS
30
Both
Steel
1.5
3600
125
961
62.2 x 30.6 x 38.6
SGE032RBAL
32
Both
Aluminum
2.4
1800
133
1271
76.8 x 35 x 46.1
SGE036RBA
36
Both
Aluminum
2.4
3600
150
1202
76.8 x 35 x 46.1
SGE036RBS
36
Both
Steel
2.4
3600
150
1255
76.8 x 35 x 46.1
SGE038RBAL
38
Both
Aluminum
2.4
1800
158
1271
76.8 x 35 x 46.1
SGE045RBA
45
Both
Aluminum
2.4
3600
188
1260
76.8 x 35 x 46.1
SGE045RBAE
45
Both
Aluminum
2.4
3600
188
1260
76.8 x 35 x 46.1
SGE045RBS
45
Both
Steel
2.4
3600
188
1313
76.8 x 35 x 46.1
SGE045RBSE
45
Both
Steel
2.4
3600
188
1313
76.8 x 35 x 46.1
SGE048RBAL
48
Both
Aluminum
5.4
1800
200
1555
76.8 x 35 x 46.1
SGE048RBALE 48
Both
Aluminum
5.4
1800
200
1555
76.8 x 35 x 46.1
SGE060RGA
60
Gas
Aluminum
2.4
3600
250
1230
76.8 x 35 x 46.1
SGE060RGS
60
Gas
Steel
2.4
3600
250
1283
76.8 x 35 x 46.1
SGE060RPA
60
Liquid Propane
Aluminum
2.4
3600
250
1230
76.8 x 35 x 46.1
SGE060RPS
60
Liquid Propane
Steel
2.4
3600
250
1283
76.8 x 35 x 46.1
SGN070RGAL
70
Gas
Aluminum
6.8
1800
279
2040
97 x 37 x 47
SGN070RGALE 70
Gas
Aluminum
6.8
1800
279
2040
97 x 37 x 47
SGN070RPAL
70
Liquid Propane
Aluminum
6.8
1800
279
2040
97 x 37 x 47
SGN070RPALE 70
Liquid Propane
Aluminum
6.8
1800
279
2040
97 x 37 x 47
SGN080RGA
80
Gas
Aluminum
5.4
3600
320
2075
116 x 37 x 55
SGN080RPA
80
Liquid Propane
Aluminum
5.4
3600
320
2075
117 x 37 x 55
SGN100RGALE 100
Gas
Aluminum
6.8
2300
417
2075
118 x 37 x 55
SGN100RPALE 100
Liquid Propane
Aluminum
6.8
2300
417
2075
119 x 37 x 55
SGN130RGAE
130
Gas
Aluminum
6.8
3600
542
2699
120 x 37 x 55
SGN130RPAE
130
Liquid Propane
Aluminum
6.8
3600
542
2699
121 x 37 x 55
SGN150RGAE
150
Gas
Aluminum
6.8
3600
600
2492
122 x 37 x 55
SGN150RPAE
150
Liquid Propane
Aluminum
6.8
3600
600
2492
123 x 37 x 55
Compatible Transfer Switch Current Catalog No.
Future Catalog No.*
SE100R
SM100R
SE100RD
SM100RD
SE150RD
SM150RD
SE200R
SM200R
SE200RD
SM200RD
SE300RD
SM300RD
SE400R
SM400R
SE400RD
SM400RD
SL600R
SM600R
SL800R
SM800R
* Single-phase transfer switches will be changing part numbers
in Fall of 2015 - does not affect three-phase switches
8
Residential generators selection & application guide
Liquid Cooled Generator Specifications/
Compatible Transfer Switches (cont.)
120/208V 3-Phase
Catalog No.
kW
Rating
Fuel
Type
Enclosure
Engine Size
(Liters)
Speed
(RPM)
Weight
Amp Output (lbs.)
Dimensions (in.)
SGE022CBAL
22
Both
Aluminum
2.4
1800
76
955
62.2 x 30.6 x 38.6
SGE025CBA
25
Both
Aluminum
1.5
3600
87
835
62.2 x 30.6 x 38.6
SGE025CBS
25
Both
Steel
1.5
3600
87
901
62.2 x 30.6 x 38.6
SGE027CBAL
27
Both
Aluminum
2.4
1800
94
955
62.2 x 30.6 x 38.6
SGE030CBA
30
Both
Aluminum
1.5
3600
104
865
62.2 x 30.6 x 38.6
SGE030CBS
30
Both
Steel
1.5
3600
104
961
62.2 x 30.6 x 38.6
SGE032CBAL
32
Both
Aluminum
2.4
1800
111
1271
76.8 x 35 x 46.1
SGE036CBA
36
Both
Aluminum
2.4
3600
125
1202
76.8 x 35 x 46.1
SGE036CBS
36
Both
Steel
2.4
3600
125
1255
76.8 x 35 x 46.1
SGE038CBAL
38
Both
Aluminum
2.4
1800
132
1271
76.8 x 35 x 46.1
SGE045CBA
45
Both
Aluminum
2.4
3600
156
1260
76.8 x 35 x 46.1
SGE045CBAE
45
Both
Aluminum
2.4
3600
156
1260
76.8 x 35 x 46.1
SGE045CBS
45
Both
Steel
2.4
3600
156
1313
76.8 x 35 x 46.1
SGE045CBSE
45
Both
Steel
2.4
3600
156
1313
76.8 x 35 x 46.1
SGE048CBAL
48
Both
Aluminum
5.4
1800
167
1555
76.8 x 35 x 46.1
SGE048CBALE
48
Both
Aluminum
5.4
1800
167
1555
76.8 x 35 x 46.1
SGE060CGA
60
Gas
Aluminum
2.4
3600
208
1230
76.8 x 35 x 46.1
SGE060CGS
60
Gas
Steel
2.4
3600
208
1283
76.8 x 35 x 46.1
SGE060CPA
60
Liquid Propane
Aluminum
2.4
3600
208
1230
76.8 x 35 x 46.1
SGE060CPS
60
Liquid Propane
Steel
2.4
3600
208
1283
76.8 x 35 x 46.1
SGN070CGAL
70
Gas
Aluminum
6.8
1800
243
2040
97 x 37 x 47
SGN070CPAL
70
Gas
Aluminum
6.8
1800
243
2040
97 x 37 x 47
SGN070CGALE
70
Liquid Propane
Aluminum
6.8
1800
243
2040
97 x 37 x 47
SGN070CPALE
70
Liquid Propane
Aluminum
6.8
1800
243
2040
97 x 37 x 47
SGN080CGA
80
Gas
Aluminum
5.4
3600
278
2075
116 x 37 x 55
SGN080CPA
80
Liquid Propane
Aluminum
5.4
3600
278
2075
117 x 37 x 55
SGN100CGALE
100
Gas
Aluminum
6.8
2300
347
2075
118 x 37 x 55
SGN100CPALE
100
Liquid Propane
Aluminum
6.8
2300
347
2075
119 x 37 x 55
SGN130CGAE
130
Gas
Aluminum
6.8
3600
451
2699
120 x 37 x 55
SGN130CPAE
130
Liquid Propane
Aluminum
6.8
3600
451
2699
121 x 37 x 55
SGN150CGAE
150
Gas
Aluminum
6.8
3600
520
2492
122 x 37 x 55
SGN150CPAE
150
Liquid Propane
Aluminum
6.8
3600
520
2492
123 x 37 x 55
Compatible Transfer Switches
SL100C
SL200C
SL400C
SL600C
SL800C
Residential generators selection & application guide
9
Liquid Cooled Generator Specifications/
Compatible Transfer Switches (cont.)
120/240V 3-Phase
Catalog No.
kW
Rating
Fuel
Type
Enclosure
Engine Size
(Liters)
Speed
(RPM)
Amp
Output
Weight (lbs.)
Dimensions (in.)
SGE022JBAL
22
Both
Aluminum
2.4
1800
66
955
62.2 x 30.6 x 38.6
SGE025JBA
25
Both
Aluminum
1.5
3600
75
835
62.2 x 30.6 x 38.6
SGE025JBS
25
Both
Steel
1.5
3600
75
901
62.2 x 30.6 x 38.6
SGE027JBAL
27
Both
Aluminum
2.4
1800
81
955
62.2 x 30.6 x 38.6
SGE030JBA
30
Both
Aluminum
1.5
3600
90
865
62.2 x 30.6 x 38.6
SGE030JBS
30
Both
Steel
1.5
3600
90
961
62.2 x 30.6 x 38.6
SGE032JBAL
32
Both
Aluminum
2.4
1800
96
1271
76.8 x 35 x 46.1
SGE036JBA
36
Both
Aluminum
2.4
3600
108
1202
76.8 x 35 x 46.1
SGE036JBS
36
Both
Steel
2.4
3600
108
1255
76.8 x 35 x 46.1
SGE038JBAL
38
Both
Aluminum
2.4
1800
114
1271
76.8 x 35 x 46.1
SGE045JBA
45
Both
Aluminum
2.4
3600
135
1260
76.8 x 35 x 46.1
SGE045JBAE
45
Both
Aluminum
2.4
3600
135
1260
76.8 x 35 x 46.1
SGE045JBS
45
Both
Steel
2.4
3600
135
1313
76.8 x 35 x 46.1
SGE045JBSE
45
Both
Steel
2.4
3600
135
1313
76.8 x 35 x 46.1
SGE048JBAL
48
Both
Aluminum
5.4
1800
144
1555
76.8 x 35 x 46.1
SGE048JBALE
48
Both
Aluminum
5.4
1800
144
1555
76.8 x 35 x 46.1
SGE060JGA
60
Gas
Aluminum
2.4
3600
180
1230
76.8 x 35 x 46.1
SGE060JGS
60
Gas
Steel
2.4
3600
180
1283
76.8 x 35 x 46.1
SGE060JPA
60
Liquid Propane
Aluminum
2.4
3600
180
1230
76.8 x 35 x 46.1
SGE060JPS
60
Liquid Propane
Steel
2.4
3600
180
1283
76.8 x 35 x 46.1
SGN070JGAL
70
Gas
Aluminum
6.8
1800
210
2040
97 x 37 x 47
SGN070JPAL
70
Gas
Aluminum
6.8
1800
210
2040
97 x 37 x 47
SGN070JGALE
70
Liquid Propane
Aluminum
6.8
1800
210
2040
97 x 37 x 47
SGN070JPALE
70
Liquid Propane
Aluminum
6.8
1800
210
2040
97 x 37 x 47
SGN080JGA
80
Gas
Aluminum
5.4
3600
249
2075
116 x 37 x 55
SGN080JPA
80
Liquid Propane
Aluminum
5.4
3600
249
2075
117 x 37 x 55
SGN100JGALE
100
Gas
Aluminum
6.8
2300
301
2075
118 x 37 x 55
SGN100JPALE
100
Liquid Propane
Aluminum
6.8
2300
301
2075
119 x 37 x 55
SGN130JGAE
130
Gas
Aluminum
6.8
3600
391
2699
120 x 37 x 55
SGN130JPAE
130
Liquid Propane
Aluminum
6.8
3600
391
2699
121 x 37 x 55
SGN150JGAE
150
Gas
Aluminum
6.8
3600
451
2492
122 x 37 x 55
SGN150JPAE
150
Liquid Propane
Aluminum
6.8
3600
451
2492
123 x 37 x 55
Compatible Transfer Switches
SL100J
SL200J
SL400J
SL600J
SL800J
10
Residential generators selection & application guide
Liquid Cooled Generator Specifications/
Compatible Transfer Switches (cont.)
277/480V 3-Phase
Catalog No.
kW
Rating
Fuel Type
Enclosure
Engine Size
(Liters)
Speed
(RPM)
Amp
Output
Weight (lbs.)
Dimensions (in.)
SGE032IBAL
32
Both
Aluminum
2.4
1800
48
1271
76.8 x 35 x 46.1
SGE036IBA
36
Both
Aluminum
2.4
3600
54
1202
76.8 x 35 x 46.1
SGE036IBS
36
Both
Steel
2.4
3600
54
1255
76.8 x 35 x 46.1
SGE038IBAL
38
Both
Aluminum
2.4
1800
57
1271
76.8 x 35 x 46.1
SGE045IBA
45
Both
Aluminum
2.4
3600
68
1260
76.8 x 35 x 46.1
SGE045IBAE
45
Both
Aluminum
2.4
3600
68
1260
76.8 x 35 x 46.1
SGE045IBS
45
Both
Steel
2.4
3600
68
1313
76.8 x 35 x 46.1
SGE045IBSE
45
Both
Steel
2.4
3600
68
1313
76.8 x 35 x 46.1
SGE048IBAL
48
Both
Aluminum
5.4
1800
72
1555
76.8 x 35 x 46.1
SGE048IBALE
48
Both
Aluminum
5.4
1800
72
1555
76.8 x 35 x 46.1
SGE060IGA
60
Gas
Aluminum
2.4
3600
90
1230
76.8 x 35 x 46.1
SGE060IGS
60
Gas
Steel
2.4
3600
90
1283
76.8 x 35 x 46.1
SGE060IPA
60
Liquid Propane
Aluminum
2.4
3600
90
1230
76.8 x 35 x 46.1
SGE060IPS
60
Liquid Propane
Steel
2.4
3600
90
1283
76.8 x 35 x 46.1
SGN070IGAL
70
Gas
Aluminum
6.8
1800
105
2040
97 x 37 x 47
SGN070IPAL
70
Gas
Aluminum
6.8
1800
105
2040
97 x 37 x 47
SGN070IGALE
70
Liquid Propane
Aluminum
6.8
1800
105
2040
97 x 37 x 47
SGN070IPALE
70
Liquid Propane
Aluminum
6.8
1800
105
2040
97 x 37 x 47
SGN080IGA
80
Gas
Aluminum
5.4
3600
120
2075
116 x 37 x 55
SGN080IPA
80
Liquid Propane
Aluminum
5.4
3600
120
2075
117 x 37 x 55
SGN100IGALE
100
Gas
Aluminum
6.8
2300
150
2075
118 x 37 x 55
SGN100IPALE
100
Liquid Propane
Aluminum
6.8
2300
150
2075
119 x 37 x 55
SGN130IGAE
130
Gas
Aluminum
6.8
3600
195
2699
120 x 37 x 55
SGN130IPAE
130
Liquid Propane
Aluminum
6.8
3600
195
2699
121 x 37 x 55
SGN150IGAE
150
Gas
Aluminum
6.8
3600
225
2492
122 x 37 x 55
SGN150IPAE
150
Liquid Propane
Aluminum
6.8
3600
225
2492
123 x 37 x 55
Compatible Transfer Switches
SL100I
SL200I
SL400I
SL600I
SL800I
Residential generators selection & application guide
11
Generator Ready Load Center
NOTE:
GENTFRSWTCH is sold separately
from Gen ready panel!
The Siemens Generator Ready Load Center can save thousands of dollars in future
generator installation expenses while keeping initial expenses to a minimum. Works with
an automatic standby generator or a portable generator.
Catalog No.
ECSBPK01 (mechanical interlock for manual or portable generation installation)
GENTFRSWTCH (auto transfer switch for automatic standby generation installation)
Automatic Transfer Switch features:
 UL Listed
 Operates automatically when connected to generator
 Transfers load from utility to generator and back to utility
 Includes: Q215 and Q2125S needed for installation
Features:
 NEMA 3R / Indoor Type 1
 225A max rated
 Flush or surface mounting
 Fits between standard stud centers
 Tin plated copper bus bars
 22 kAIC rated
 120/240V, 1 Phase
 Main lug – convertible to main breaker with addition of MBK150A, MBK200A,
or MBK225A
 Installation of transfer mechanism can be performed at time of generator installation
A
E
F
S
S
D
A
12
B
Generator Ready Load Center with
Automatic Standby generator installation
Residential generators selection & application guide
D
C
B
Traditional Installation
F
E
C
Generator Ready Load Center with
Portable Generator installation
Generator Ready Load Center (cont.)
200A Main Breaker
Indoor enclosure - NEMA Type 1
Outdoor enclosure - NEMA Type 3R
Dimensions (inches)
Dimensions (inches)
Brand
One inch
spaces*
Max
circuits*
Catalog No.
Height
Width
Depth
Catalog No.
Height
Width
Depth
Siemens
30
42
G3042B1200GEN
42.00
14.25
4.00
W3042B1200GEN
42.00
14.63
4.00
Murray
30
42
LC3042B1200GEN
42.00
14.25
4.00
LW3042B1200GEN
42.00
14.63
4.00
225A Main Lug
Indoor enclosure - NEMA Type 1
Outdoor enclosure - NEMA Type 3R
Dimensions (inches)
Dimensions (inches)
Brand
One inch
spaces*
Max
circuits*
Catalog No.
Height
Width
Depth
Catalog No.
Height
Width
Depth
Siemens
30
42
G3042L1225GEN
42.00
14.25
4.00
W3042L1225GEN
42.00
14.63
4.00
Murray
30
42
LC3042L1225GEN
42.00
14.25
4.00
LW3042L1225GEN
42.00
14.63
4.00
*2 spaces & 2 circuits are reserved for standby generator installation.
Install ECSBPK01
for portable
generators
Install GENTFRSWTCH
for automatic standby
generators
NOTE:
GENTFRSWTCH is sold separately
from Gen ready panel!
G3042L1225GEN
Residential generators selection & application guide
13
Portable Generators
5.5, 6.5, 7.5, 8, 15, 17.5 kW
Features and ratings
 Ideal for residential emergency
and job-site power
 Gasoline powered, OHV engine
 Include handles and wheels
for easy movement
 Hour meter included
 Large variety of outlets
 Low noise muffler
 2 year residential warranty
 Easily integrated into home
electrical systems with Siemens
breaker interlock kits (pictured below)
PG0055
PG0065
PG0075Ea
PG0080Ea
PG015a
PG017a
Rated Power
5.5 kW
6.5 kW
7.5 kW
8 kW
15 kW
17.5 kW
Surge
6.875 kW
8 kW
9.37 kW
10 kW
22.5 kW
26.2 kW
Rated Amps @
60Hz 120/240, 1Ø,
1.0 pf
22.9
27.1
31.2
33.3
62.5
73
Engine RPM
3600
3600
3600
3600
3600
3600
Fuel Capacity
(gallons)
6.6
6.6
8
8
16
16
Dimensions
(inches)
34 x 26.5 x 27.5
34 x 27 x 28
28.75 x 26.75 x 26
34 x 27 x 28
39 x 31 x 49
39 x 31 x 49
Weight (lbs)
180
172
201
192
450
475
a Manual Electric Starter
Portable Accessories:
 5715 - Lifting Beam Kit; 6.5 kW & 8.0 kW
Refer to page 12 for Portable Maintenance Kits
14
Residential generators selection & application guide
Load Centers
Manual Transfer Interlock Kits for Load Centers and Meter Combinations
Convert load centers or meter combinations into standby power panels
Standard features
 UL listed for use in most
Siemens load centers and meter
combinations
Panels in which the bussing or wire
forms from the meter socket land on
main lugs are not acceptable for use in
standby systems because turning the
main breaker to “OFF” does not prevent
feedback to the utility power lines.
Examples of such panels include catalog
numbers that start with the
following letters.
MC0606L1200*
Standby power
main breaker
Utility main breaker
MM0406L1*
MC1212L1200*
 Suitable for use with optional
standby systems in accordance
with article 702 of the National
Electric Code
 Corrosion resistant finish
 Easy assembly requiring no
Wire forms
or bussing
modifications to the load center
or meter combination
To activate standby power the utility main
breaker must be in the “OFF” position to
prevent dangerous feedback between the
power sources.
 Remains attached to the main
breakers when load center cover
Acceptable usage of Interlock Kits by load center/meter combination catalog numbers
ES Series Load Centers
can utilize interlock kits:
1, 2, 5, 6, 7. Kits 3 and 4
can also be used on main
breaker panels.
Siemens Meter Combinations
MC0816B1150RTH
5
7
MC2040B1200
5
7
MC0816B1150T
5
7
MC2040B1200R
5
7
MC0816B1150TH
5
7
MC2442B1200FEC
2
MC0816B1200FCTM
2
MC2442B1200SEC
2
MC0816B1200RT
5
7
MC3040B1200SECW
5
MC0816B1200RTB
5
7
MC3042B1200FED
3
MC0816B1200RTH
5
7
MC3042B1200SED
3
MC0816B1200SCTM
2
MC3042B1225FED
3
MC0816B1200T
7
MC3042B1225SED
3
MC0816B1200TH
5
7
MC4040B1200SECW
5
MC0816B1350RLTM
5
7
MC0816B1200RJBT
8
MC0816B1400RLTM
5
7
MC0816B1150RJBT
8
MC1224B1100FEC
2
MC0816B1200RCT
8
MC1224B1100SEC
2
MC0816B1150RCT
8
MC1224B1125
1
MC0816B1200CT
8
MC1224B1125FEC
2
MC0816B1150CT
8
When used in horizontal positions as typical in
most load centers, ECSBPK07 is recommended for
use only with QNR type circuit breakers.
MC1224B1125SEC
2
MC2040B1150RCT
9
MC1632B1100SEC
2
MC2040B1150CT
9
Standby power interlock kits are not intended for use
with AFCI, GFCI, 3-pole or 1/2” frame circuit breakers
and 4 space, 125 amp load centers.
MC1632B1125FEC
2
MC2040B1200RCT
9
MC2040B1150
5
MC2040B1200CT
9
PL Series Load Centers
can utilize interlock kits:
1, 2, 3, 4, 5, 6, 7.
Numbers 1 through 9 in these tables represent
the last digit in each interlock kit catalog number.
Example: 1 = ECSBPK01
2
7
7
7
Siemens type EQ load centers using a “4-pole” main
breaker do not have a kit available to interlock this
main to branch circuits. Branch circuit positions can
be interlocked.
Residential generators selection & application guide
15
Manual Transfer Interlock Kits
a
Prevents dangerous feedback between two sources of power
Usage
Information
Utility Main
Breaker Types
Standby Main
Breaker Types
Interlock
Number
ECSBPK01
For use on load centers or meter combinations
that will accept 2-pole circuit breakers opposite
one another as shown.
QP, QPH, HQPH
QP, QPH, HQPH
1
ECSBPK02
For use on load centers or meter combinations
that will accept 2-or 4-pole next to a 2-pole circuit
breaker side by side as shown.
QP, QPH, HQPH
QP, QPH, HQPH
2
ECSBPK03b
For use on Ultimate™ and Rock Solid load centers,
150 amp and higher, to connect the main breaker
to a 2-pole circuit breaker.
MBK150A,
MBK200A, OR
MBK225A
QP, QPH, HQPH
3
ECSBPK04
For use on Ultimate™ and Rock Solid load centers,
125 amp and lower, to connect the main breaker
to a 2-pole circuit breaker.
MBK100A or
MBK125A
QP, QPH, HQPH
4
ECSBPK05
For use on load centers or meter meter
combinations that will accept a QNR (MD-TR)
frame circuit breaker next to a 2-pole circuit
breaker as shown.
QNR, QNRH, HQNR
QP, QPH, HQPH
5
ECSBPK06b
For use on load centers or meter combinations
that will accept a QN (MD-T) frame circuit breaker
next to a 2-pole circuit breaker as shown.
QN, QNH, HQN
QP, QPH, HQPH
6
ECSBPK07
For use on load centers or meter combinations
that will accept two QNR (MD--TR) circuit breakers
side by side as shown OR will accept two QN (MD-T) circuit breakers side by side as shown.
QNR, QNRH, HQNR,
QN, QNH, HQN
QNR, QNRH, HQNR
QN, QNH, HQN
7
ECSBPK08b
For use on 8 space, over/under, OH/UG feed meter
combinations as shown. Limited application
to specific catalog numbers.
QPP, QPPH
QP, QPH, HQPH
8
ECSBPK09b
For use on 20 space, over/under, OH/UG feed
meter combinations as shown. Limited application
to specific catalog numbers.
QPP, QPPH
QP, QPH, HQPH
9
Catalog No.
a Manual breaker interlock kits are attached to the breakers not the trim of the load center.
b This interlock kit takes up 2 spaces adjacent to the 2-pole breaker being interlocked. Those spaces cannot accommodate filler plates.
16
Residential generators selection & application guide
Standby Generator Ratings / Maintenance Kits
Generator Ratings
kW Rating
(LP/NG)
Rated Amps
Engine RPM at
full load
Natural gas fuel
consumption
(ft^3/hr)
Liquid propane
vapor
consumption
N(gal/hr)
Propane vapor
consumption
ft^3/ft
Sound
level at
normal
load
Sound level
at exercise
8/7
35
3600
118.9
1.47
51.4
62
N/A
11/10
50
3600
160.3
2.08
72.7
63
N/A
16/16
65
3600
312
3.57
130
66
60
20/18
90
3600
303.4
3.99
139.5
66
60
22/19.5
100
3600
281
3.68
127
67
58
for Btu content, multiply ft^3/hr x 2520 (LP) or ft^3/hr x 1000
Oil and Air Filter Kits
ASGE
ASGN
Catalog No.
Usage
Catalog No.
Usage
GENMKIT19
8 kW 410cc
GENMKIT10
8 kW 410cc
GENMKIT20
11 kW 530cc
GENMKIT2
10 kW 530cc
GENMKIT21
14,16 kW 992cc
GENMKIT3
14, 17 kW 990cc
GENMKIT22
20, 22 kW 999cc
GENMKIT11
20 kW 990cc
PORTMKIT1
Portable 15, 17.5 kW
PORTMKIT2
Portable 5, 6.5 kW
PORTMKIT3
Portable 8 kW
Maintenance Kits
Just like an engine in an automobile,
generator engines require routine
maintenance. Service kits, which include oil
and air filters, are available and are selected
based on engine size. Touch up paint is also
provided to help cover minor scratches.
Accessories
Catalog No.
Usage
Battery*
525cca group 26R
5621
Auxiliary Transfer Switch Contact
GENPAINT
Gray Touch Up Paint for 2007 units
GENPAINT2
Generator Spray Paint Gray Textured
GENSHELL2
Display Shell, gray color
6212
Air Cooled Cold Weather Kit
6186
PMM Module
6199
PMM Starter Kit
6873
Smart Management Module - load management system that operates autonomously
6424
Brown Out Kit
5951
The Wireless Generator Monitoring System provides remote monitoring capability for convenient indoor observation.
By adding this item, a generator owner can observe generator function, set certain operation parameters and receive
maintenance reminders. Advanced Wireless Remote in Home Monitor
5928
Standard Wireless Remote in Home Monitor
GENCART
The Generator Transport Cart is designed to allow a single individual to move and position any of the air-cooled generators
without the need for additional people or equipment. By attaching the cart to the generator through the lifting holes, the
generator is lifted from the pallet by leverage and is easily wheeled to the appropriate location for final setting
5666
The pad skirt snaps together around the bottom of the new 20kW generators. This offers a sleek, contoured appearance as
well as offering protection from rodents and insects by covering the lifting holes located in the base. Available in grey, the
pad skirt fits 20kW generators manufactured after 4/2008.
6510
E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.
* Not included
Residential generators selection & application guide
17
Mobile Link
Cellular remote monitoring system for your generator
6463 – Mobile Link
6478 – Liquid-Cooled Extension Cable
Note: this cable is required with Mobile Link for all liquid-cooled units.
Compatibility:
Mobile Link is designed for use with a generator equipped with an LCD display. Mobile
Link is compatible with most 2008-and-newer air-cooled standby generators and
2010-and-newer liquid-cooled standby generators.
Note: Please ensure you have cellular service in your area before purchasing.
Email or Text Notifications:
StandbyStatus.com provides over 40 different notifications, including successful exercise,
maintenance reminders, change in status, low battery, fault alert and more:
When maintenance is required or fault conditions occur, StanbyStatus.com automatically sends out alerts
 Dealer gets accurate data and can respond quickly and efficiently to problems
 Customers designate up to 4 different accounts to receive email and text notifications, including their dealer, so that they can discuss options with the customer to address the generator’s issues.
 Notifications drive regular, timely communication with the customer
StandbyStatus.com:
StandbyStatus.com features a user-friendly dashboard that allows the customer to check
their generator’s status anytime, anywhere:
 View current generator status and upcoming maintenance needs
 Remotely set exercise schedule
 Review run and maintenance history
 Get local weather updates
 Change messaging settings
How does it work?
18
Residential generators selection & application guide
8QLW6WDWXV
%DWWHU\9ROWDJH
)UHTXHQF\+]
Fuel Pipe Sizing
Natural Gas Pipe sizing
kW
0.75”
1”
1.25”
8
55’
150’
600’
11
20’
65’
250’
1.5”
2”
2.5”
3”
500’
16
20’
100’
200’
20
20’
100’
200’
AC 22
20’
100’
200’
LC 22
15’
115’
260’
799’
25
10’
95’
175’
575’
27
80’
450’
552’
30
60’
125’
450’
32
60’
125’
450’
36
35’
95’
370’
915’
38
35’
95’
370’
915’
45
15’
60’
260’
650’
48
50’
230’
585’
60
25’
145’
375’
1100’
70
5’
75’
225’
710’
80
65’
195’
630’
100
40’
140’
460’
130
50’
215’
150
30’
150’
2.5”
3”
Liquid Propane Pipe Sizing
kW
0.75”
1”
1.25”
8
165’
450’
11
70’
300’
900’
16
20’
70’
350’
20
15’
50’
250’
AC 22
15’
50’
250’
85’
365’
LC 22
1.5”
25
60’
275’
605’
27
55’
260’
575’
30
40’
195’
435’
32
40’
195’
435’
36
20’
125’
290’
38
20’
2”
1030’
125’
290’
1030’
45
82’
195’
725’
48
70’
165’
620’
60
45’
115’
445’
1095’
70
20’
60’
260’
660’
80
15’
50’
230’
590’
30’
100
165’
430’
1305’
130
70’
205’
660’
150
45’
150’
490’
*pipe lengths denoted are in max feet usable
Residential generators selection & application guide
19
Notes
20
Residential generators selection & application guide
Notes
Residential generators selection & application guide
21
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
info.us@siemens.com
www.usa.siemens.com/generators
Subject to change without prior notice
Order No.: RPSA-GEN02-0815
All rights reserved
Printed in USA
© 2015 Siemens Industry, Inc.
The information provided in this brochure contains merely
general descriptions or characteristics of performance
which in case of actual use do not always apply as described
or which may change as a result of further development
of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.