Selection and application guide Residential Standby Power Systems For residential generators Read the QR code with the QR reader in your mobile! www.usa.siemens.com/generators Contents 1 Industry Leading System Controls 2-3 Generator Features Catalog Logic - Easy Order Selection Guide 4 Air Cooled Standby Generators* 5 Liquid Cooled Standby Generators 6 SE and ST Type Transfer Switches 7 Liquid Cooled Generator Specifications/Compatible Transfer Switches 8-11 Generator Ready Load Center 12-13 14 Portable Generators 15-16 Manual Transfer Interlock Kits Standby Generator Ratings / Maintenance Kits 17 Mobile Link 18 Fuel Pipe Sizing 19 5 Year WARRANTY ASGE Home Standby Generator 5 Year Limited Warranty Years 1 & 2 Limited comprehensive coverage on mileage*, labor, parts Year 3 Limited comprehensive coverage on parts Years 4 & 5 limited comprehensive coverage on engine (short block) & alternator (rotor and stator) parts only *A Siemens ATS is highly recommended to be used in conjunction with the generator set. If a non-Siemens ATS is substituted for use and directly causes damage to the generator set, no warranty coverage shall apply. - Siemens or Generac Manufactured ATS ii Residential generators selection & application guide Industry Leading System Controls Low Voltage Shutdown Shuts down the generator at <60% voltage for 5 seconds to better protect home owners appliances or connected items. Internal Fault Shutdown Shuts down the generator when a failure is detected within the Evolution Controller for more protection and easier diagnostics. Battery Sentinel Monitors the battery and charging system to indicate that the battery is trending towards failure or that it has failed. Evolution controller for air cooled generators Type "E" Evolution Digital LCD Controller Functions include monitoring utility power, triggering the automatic transfer switch, starting and stopping the generator, exercising the generator, and monitoring the generator for any system faults. High Voltage Shutdown Shuts down the generator at >130% rated voltage for 200 milliseconds or >110% for 5 seconds to better protect home owner appliances or connected items. Event Log All generators 8-22 kW feature a full event log capable of recording 50 events. Smart Battery Charger Only delivers a charge to the battery when needed. Battery charge depends on ambient air temperature. Voltage Regulation With the combination into the Evolution Controller, the voltage regulation delivers an industry leading voltage regulation +/- 1%. Product Activation Requires each generator to be activated via website or phone before automatic function is enabled - Allows a warranty activation start point for every generator sold. External Common Fault Alarm The Evolution Controller has a provision to connect to a set of contacts that will allow for a common alarm when any of the generator shut downs occur- This will allow individuals to connect into security systems, home automation systems or simply drive a different alarm within a home or business. Adjustable generator start time When utility fails, the control is factory set to delay 10 seconds prior to starting the engine. There is also the capability to change the delay time between 2-1500 seconds . Incorrect Wiring Error Eliminates the potential of damaging the Evolution Controller if it is not connected properly, a warning message is displayed that must be corrected before the controller is allowed to be fully operational. Air Cooled Evolution Controller Stack up Orange text indicates a new feature or different way of annunciation Display Alarms Dealer service features/menus Key miscellaneous LCD Display LED Backlit Membrane Keypad Time & Date Alarm Log Run Log Maintenance Log & Reminders Set Exercise via Display Run Hour Display Battery Condition Quad-lingual Display (Portuguese) Quiet Test Selection Fuel Selection Elimination of "Inspect" prompt Capture of Dismissal of Maintenance Reminder Prompt Variable Start Up Delay between 2-1500 seconds Generator Over Voltage Generator Under Voltage Underspeed/Fail to Xfer Low Battery Voltage High Engine Temperature Low Oil Pressure Overcrank Overspeed RPM Sensor Loss Internal Fault Low Fuel Pressure (QT only) Wiring Error External common fault alarm Overload Warning/Cooldown Low Battery/Battery Problem Charger Warning Charger Missing AC Stepper Over Current Fuse Problem Radio Signal Indication Improved Smart Battery Charger Charging Status Battery Voltage USB Port Generator Output Voltage Output Frequency & RPM Utility Input Voltage Software & Hardware Version Boot Loader Version Command Status Voltage Calibration Parameter Group Votage Code Maintenance Hard Reset Edit Run Hours (controller replacement) Maintenance Schedule Service/Monitoring Port Serial Number Debug Updateable Firmware Prompts Brown Out Voltage Compatible with Cellular Monitoring Product Activation Voltage Regulator Exercise not set error •Certain faults will also have an associated E-code after the general message to specifically call out what the exact problem for more exact/quick diagnosis. Residential generators selection & application guide 1 Generator Features Substructure Galvannealed substructure for excellent rust protection. Natural gas/liquid propane fuel setup The 8 - 22 kW units ship from the factory ready for use with natural gas. The conversion to propane is as simple as turning a knob. No tools required! Exhaust enclosure Verify spacing with local code and inspector, prior to installation. Typically, the generator must be placed away from any opening in the house due to exhaust regulations from NFPA guidelines. Wind resistant housing 150 MPH wind resistant design on both steel and aluminum units, ASCE 7 Standards. Electrostatically applied textured epoxy paint for added durability. Composite base Air cooled units are provided with composite mounting pad. Liquid cooled units require a concrete slab. Oil dipstick, low oil switch, high temperature switch, oil filter, oil drain hose Break in periods are not required on Siemens standby generators to initiate the warranty, but are recommended. Generator back view Snap-in cover plate Easy access for remote wireless monitor. Refer to page 12 for monitor offering. Fuel line connection A section of UL or AGA approved flexible fuel line is required to protect the rigid fuel line connections against generator vibration. 1' flexible fuel line connector is included. 2 Residential generators selection & application guide Air filter Prolong the life of your engine through routine maintenance and ensure warranty requirements are met. Maintenance is recommended annually or every 200 hours. Refer to page 12 for maintenance kit offerings. External breaker connections 180º swing door capability and prop rod allows full range of motion for ease of access during installation as well as servicing on 8 - 22 kW units. External mainline circuit breaker Power shutdown eliminates the need to open the enclosure. Meets fire marshall code. LED indicator lights included on 8-22 kW New features • Green = Generator OK • Yellow = Maintenance needed (not on 8-14kW) • Red = Contact dealer New Brighter LED indicator lights Door improvement with lip to prevent water from leaking in. Control panel Evolution controller functions include monitoring utility power, triggering the automatic transfer switch, starting and stopping the generator, exercising the generator, and monitoring the generator for any system faults. Combines the voltage regulator, engine control board and battery charger into one single item Brings more functionality to the generator control for a smarter power solution Larger battery compartment Batteries are not included and must be purchased separately. The recommended battery is a 26 frame battery capable of 525550cca. Product Activation is required on all Evolution Controlled Models to engage automatic transfer mode. Generator will operate in manual mode until activation code is entered. Easy, one-time activation process can be completed in shop or on-site. Data label is located inside the generator. Serial number is required for generator activation. Residential generators selection & application guide 3 Catalog Logic Easy order selection guide Liquid Cooled Air Cooled Standby Power Generators ASGE SGE SGN kW ratingsab Voltage R = 120/240V, 1 x C = 208/120V, 3 x J = 240/120V, 3x I = 480/277V, 3 x 8 11 16 20 22 22 25 27 30 32 36 38 45 48 60 70 80 100 130 150 Fuel G = Natural Gas P = Liquid Propane Vapor B = Accepts Both R R R R R R, C, J R, C, J R, C, J R, C, J R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I R, C, J, I B B B B B B B B B B B B B B G, P G, P G, P G, P G, P G, P Enclosure S = Steel A = Aluminum Speed Left Blank = 3600rpm L = 1800rpm S A, S A, S S A A A, S A A, S A A, S A A, S A A, S A A A A A Emissions Compliant Optioncd E = Catalyst L L L L L E E L E L E E E Future Part Numbers Voltage Transfer Switches R = 120/240V, 1 x ST=Indoor Branch Circuit C = 208/120V, 3 x Service Disconnect J = 240/120V, 3 x Left Blank = No Branch SL=Outdoor Load Shedding Circuits SE=Load Management* Amp I = 480/277V, 3 x D = Yes ST SL SE* 50 R 10C, 12C 100 R 16C 100 C, J, I 200 C, J, I 400 C, J, I 600 R,C, J, I Transfer Switches ST= Indoor Branch Circuit SL = Outdoor Load Shedding SM = Load Management** Amps ST SL Voltage R = 120/240V,1x C = 208/120V, 3x J = 240/120V, 3 x I = 480/277V, 3 x Service Disconnect Left Blank = No Branch D = Yes Circuits 50 R 10C, 12C 100 R 16C 100 C, J, I 200 C, J, I 400 C, J, I 600 C, J, I 800 R,C, J, I 800 C, J, I 100 R Blank, D 100 R Blank, D 150 R D 150 R D 200 R Blank, D 200 R Blank, D 300 R D 300 R D 400 R D 400 R D *The prefix “SM” will be replacing the previous “SE” and “SL” prefixes for Single Phase Transfer Switches ONLY in the Fall of 2015 - See table to the right. SM 600** R 800** R ** Will have Outdoor Load Shedding and Load Management Capabilities a Battery not included for units 60kW and below. b Catalyst option available on 45, 48, and 70kW units, catalyst factory standard on 100-150kW units. c All units 30kW and below do not fall under CA/MA emissions standards, therefore are not required to have a catalyst. d All units 32kW and above must contain emissions catalyst in order to be installed in California/Massachusettes (part number ending with "E"). 4 Residential generators selection & application guide Air Cooled Standby Generators 8, 11, 16, 20, and 22kW 120/240V, 1 phase Standard features UL 2200 Listed Four-cycle industrial engines provide durable, reliable, long life Operate on either natural gas or propane vapora Composite mounting pad approved to eliminate need to pour concrete padb Automatic high temperature, low oil pressure, over speed, and over crank shut down Low battery voltage indicator Standard safety fuse Provided with Type "E" Evolution controller Typical load requirementsc Description kW Electric Heat per 1,000 ft. b General Residential Motor Load Reference 12.0 Heat Pump Elements per 1,000 ft.b 7.0 Dryer 5.5 Running Load Description hp Running kW Amps at 120v 1ø Amps at 1240v 1ø Refrigerator, sump pump, furnace, garage opener 0.5 0.5 4.9 2.5 Hot Tub 5.0 Range Oven 5.0 Freezer, washer, septic grinder 0.75 0.75 7.4 3.7 Hot Water Heater 4.5 General 1hp 1 1 9.8 4.9 Stove Top Burner 1.5 Well & septic lift pump 2 2 19.6 9.8 General Receptacles per 1,000 ft.b 1.0 Dishwasher 1.5 Blow Dryer 1.3 AC (per ton) 1.0 Microwave 1.0 Toasters Lighting per 1,000 ft. b Starting Load Starting kW LR Amps at 120v 1ø LR Amps at 240v 1ø Refrigerator, sump pump, furnace, garage opener 0.5 1.5 25 13 Freezer, washer, septic grinder 0.75 2.3 38 19 1.0 General 1hp 1 3 50 25 0.8 Well & septic lift pump 2 6 100 50 Catalog Numbera kW Ratingc Enclosure Type Engine Size Weight (lbs.) ASGE008RBS 8 Steel 410CC 360 GENMKIT19 ASGE011RBS 11 Steel 530CC 448 GENMKIT20 ASGE011RBA 11 Aluminum 530CC 428 GENMKIT20 ASGE016RBA 16 Aluminum 992CC 448 ASGE016RBS 16 Steel 992CC 513 GENMKIT21 ASGE020RBS 20 Steel 999CC 516 GENMKIT22 ASGE022RBA 22 Aluminum 999CC 526 GENMKIT22 Dimensions (in.) 48 x 25 x 29 Maintenance Kits GENMKIT21 aAll units ship ready for use with natural gas, minor adjustments required for liquid propane vapor use. bCheck local code requirements. c Battery not included with air cooled models 8-22kw. Refer to page 12 for 26R battery. Residential generators selection & application guide 5 Liquid Cooled Generators 1800, 2300, and 3600 RPM, 1Phase and 3 Phase Standard features UL 2200 Listed Meets EPA Emission Regulations (units 45kW and above must have emissions catalyst to be used in CA/MA) Operate on either natural gas or propane vapor Automatic high temperature, low coolant, low oil pressure, and over speed shutdown Automatic voltage regulator with over voltage protection Isochronous Electronic Governor Safety fuse included Smart Battery Charger Quiet run weekly self test Provided with type "E" evolution controller (8-60kW units) or type "N" Nexus controller (70-150kW) Compatible with "SE", "SL", and future "SM" type automatic transfer switches Air Cooled Standby Power Generators ASGE Liquid Cooled SGE SGN kW ratingscd Voltage R=120/240v, 1 phase C=208/120v, 3 phase J=240/120v, 3 phase I=480/277v, 3 phase Fuel G=Natural Gas P=Liquid Propane Vapor B=Accepts Both Enclosure S=Steel A=Aluminum 8 R B S 11 R B A 16 R B A, S 20 R B S 22 R B A 22 R, C, J B A 25 R, C, J B S 27 R, C, J B A 30 R, C, J B A, S 32 R, C, J, I B A 36 R, C, J, I B A, S 38 R, C, J, I B A 45 R, C, J, I B A, S 48 R, C, J, I B A 60 R, C, J, I G, P A, S Speed Left Blank = 3600rpm L=1800rpm L* L* L* L* E L* E L* E L* E 70 R, C, J, I G, P A 80 R, C, J, I G, P A 100 R, C, J, I G, P A 130 R, C, J, I G, P A E 150 R, C, J, I G, P A E a All units 38kW and below do not fall under CA/MA emissions standards, therefore are not required to have a catalyst b All units 45kW and above must contain emissions catalyst to be installed in California/Massachusettes (part number ending with “E”) c Battery not included for units 60kW and below d Catalyst option available on 45, 48, and 70kW units, catalyst factory standard on 100-150kW units * Denotes speed of 2300RPM 6 Emissions Compliant Optionab E=Catalyst Residential generators selection & application guide Transfer Switches SE Type transfer switches Transfer switches provide the mechanism for transferring power between utility and generator service. Engineered with Digital Power Management (DPM) technology. 100-400A single phase SE Type transfer switches have the ability to cycle on and off two air conditioners without adding additional components, allowing for a smaller generator to cover more circuits than when paired with a standard transfer switch. Features and ratings 100-400A Outdoor NEMA 3R aluminum enclosure Open transition Service rated and non-service rated Cover more circuits with a smaller generator Compatible with Evolution and NEXUS controllers Cover every circuit when paired with a higher kW generator Add additional PMM modules (6186) and manage up to four more large loads on single phase SE type transfer switches Catalog No.* Future Catalog No.a SE100R SM100R SE100RD SM100RD SE150RD SM150RD SE200R SM200R SE200RD SM200RD SE300RD SM300RD SE400R SM400R SE400RD SM400RD Amp Branch Circuits KA Rating (in Amps) 100 150 10,000 200 300 22,000 400 Weight (lbs.) Dimensions (in.) Enclosure Type 20 20 x 14.6 x 7.09 Aluminum 23 21 x 14.6 x 7.09 Aluminum 39 30 x 13.5 x 6.3 Aluminum 20 20 x 14.6 x 7.09 Aluminum 39 30 x 13.5 x 6.3 Aluminum 140 48 x 21.82 x 10.06 Aluminum 133 36 x 24 x 10.6 Aluminum 140 48 x 21.82 x 10.06 Aluminum a Denotes new parts launching Fall 2015. * kW rating is from 8 to 20kW on each switch listed/NEMA 3 rating for each. "ST" Type transfer switches* "ST" type transfer switches are compatible with the Evolution and NEXUS controllers. The controller senses power outages and initiates the transfer of power to the generator via the automatic transfer switch. Features and ratings 30 ft. pre-wired conduit for connecting the transfer switch to the external connection box 2 ft. pre-wired conduit for moving circuits from the main panel to the transfer switch Pre-wired external connection box with a weatherproof conduit for generator connections Compatible with Evolution and NEXUS controllers Electrically operated, mechanically contacts for fast, positive connections Rated for all classes of load,100% equipment rated, both inductive and resistive 160 millisecond transfer time Open transition 50 amps = 10 & 12 circuit, single coil design, flush mountable Express install kit included 100 amps = 14 & 16 circuit, dual coil design Main contacts are silver plated or silver alloy to resist welding and sticking Suitable for use only on air cooled products (8–17 kW) Catalog No. ST050R10C ST050R12C ST100R16C Amp 50 100 kW rating Branch circuits 8 10 11 12 17 16 KA rating (Amp) Wt. (lbs.) 57 10,000 61 68 Dimensions (in.) 22.5 x 15.4 x 3.8 29.25 x 12.5 x 7 NEMA rating Enclosure 1 ST 1 ST 1 ST *Disconnect included SMD models (service rated) SM or SE models Residential generators selection & application guide 7 Liquid Cooled Generator Specifications/ Compatible Transfer Switches 120/240V Single-Phase Catalog No. kW Rating Fuel Type Enclosure Engine Size (Liters) Speed (RPM) Amp Output Weight (lbs.) Dimensions (in.) SGE022RBAL 22 Both Aluminum 2.4 1800 92 955 62.2 x 30.6 x 38.6 SGE025RBA 25 Both Aluminum 1.5 3600 104 835 62.2 x 30.6 x 38.6 SGE025RBS 25 Both Steel 1.5 3600 104 901 62.2 x 30.6 x 38.6 SGE027RBAL 27 Both Aluminum 2.4 1800 113 955 62.2 x 30.6 x 38.6 SGE030RBA 30 Both Aluminum 1.5 3600 125 865 62.2 x 30.6 x 38.6 SGE030RBS 30 Both Steel 1.5 3600 125 961 62.2 x 30.6 x 38.6 SGE032RBAL 32 Both Aluminum 2.4 1800 133 1271 76.8 x 35 x 46.1 SGE036RBA 36 Both Aluminum 2.4 3600 150 1202 76.8 x 35 x 46.1 SGE036RBS 36 Both Steel 2.4 3600 150 1255 76.8 x 35 x 46.1 SGE038RBAL 38 Both Aluminum 2.4 1800 158 1271 76.8 x 35 x 46.1 SGE045RBA 45 Both Aluminum 2.4 3600 188 1260 76.8 x 35 x 46.1 SGE045RBAE 45 Both Aluminum 2.4 3600 188 1260 76.8 x 35 x 46.1 SGE045RBS 45 Both Steel 2.4 3600 188 1313 76.8 x 35 x 46.1 SGE045RBSE 45 Both Steel 2.4 3600 188 1313 76.8 x 35 x 46.1 SGE048RBAL 48 Both Aluminum 5.4 1800 200 1555 76.8 x 35 x 46.1 SGE048RBALE 48 Both Aluminum 5.4 1800 200 1555 76.8 x 35 x 46.1 SGE060RGA 60 Gas Aluminum 2.4 3600 250 1230 76.8 x 35 x 46.1 SGE060RGS 60 Gas Steel 2.4 3600 250 1283 76.8 x 35 x 46.1 SGE060RPA 60 Liquid Propane Aluminum 2.4 3600 250 1230 76.8 x 35 x 46.1 SGE060RPS 60 Liquid Propane Steel 2.4 3600 250 1283 76.8 x 35 x 46.1 SGN070RGAL 70 Gas Aluminum 6.8 1800 279 2040 97 x 37 x 47 SGN070RGALE 70 Gas Aluminum 6.8 1800 279 2040 97 x 37 x 47 SGN070RPAL 70 Liquid Propane Aluminum 6.8 1800 279 2040 97 x 37 x 47 SGN070RPALE 70 Liquid Propane Aluminum 6.8 1800 279 2040 97 x 37 x 47 SGN080RGA 80 Gas Aluminum 5.4 3600 320 2075 116 x 37 x 55 SGN080RPA 80 Liquid Propane Aluminum 5.4 3600 320 2075 117 x 37 x 55 SGN100RGALE 100 Gas Aluminum 6.8 2300 417 2075 118 x 37 x 55 SGN100RPALE 100 Liquid Propane Aluminum 6.8 2300 417 2075 119 x 37 x 55 SGN130RGAE 130 Gas Aluminum 6.8 3600 542 2699 120 x 37 x 55 SGN130RPAE 130 Liquid Propane Aluminum 6.8 3600 542 2699 121 x 37 x 55 SGN150RGAE 150 Gas Aluminum 6.8 3600 600 2492 122 x 37 x 55 SGN150RPAE 150 Liquid Propane Aluminum 6.8 3600 600 2492 123 x 37 x 55 Compatible Transfer Switch Current Catalog No. Future Catalog No.* SE100R SM100R SE100RD SM100RD SE150RD SM150RD SE200R SM200R SE200RD SM200RD SE300RD SM300RD SE400R SM400R SE400RD SM400RD SL600R SM600R SL800R SM800R * Single-phase transfer switches will be changing part numbers in Fall of 2015 - does not affect three-phase switches 8 Residential generators selection & application guide Liquid Cooled Generator Specifications/ Compatible Transfer Switches (cont.) 120/208V 3-Phase Catalog No. kW Rating Fuel Type Enclosure Engine Size (Liters) Speed (RPM) Weight Amp Output (lbs.) Dimensions (in.) SGE022CBAL 22 Both Aluminum 2.4 1800 76 955 62.2 x 30.6 x 38.6 SGE025CBA 25 Both Aluminum 1.5 3600 87 835 62.2 x 30.6 x 38.6 SGE025CBS 25 Both Steel 1.5 3600 87 901 62.2 x 30.6 x 38.6 SGE027CBAL 27 Both Aluminum 2.4 1800 94 955 62.2 x 30.6 x 38.6 SGE030CBA 30 Both Aluminum 1.5 3600 104 865 62.2 x 30.6 x 38.6 SGE030CBS 30 Both Steel 1.5 3600 104 961 62.2 x 30.6 x 38.6 SGE032CBAL 32 Both Aluminum 2.4 1800 111 1271 76.8 x 35 x 46.1 SGE036CBA 36 Both Aluminum 2.4 3600 125 1202 76.8 x 35 x 46.1 SGE036CBS 36 Both Steel 2.4 3600 125 1255 76.8 x 35 x 46.1 SGE038CBAL 38 Both Aluminum 2.4 1800 132 1271 76.8 x 35 x 46.1 SGE045CBA 45 Both Aluminum 2.4 3600 156 1260 76.8 x 35 x 46.1 SGE045CBAE 45 Both Aluminum 2.4 3600 156 1260 76.8 x 35 x 46.1 SGE045CBS 45 Both Steel 2.4 3600 156 1313 76.8 x 35 x 46.1 SGE045CBSE 45 Both Steel 2.4 3600 156 1313 76.8 x 35 x 46.1 SGE048CBAL 48 Both Aluminum 5.4 1800 167 1555 76.8 x 35 x 46.1 SGE048CBALE 48 Both Aluminum 5.4 1800 167 1555 76.8 x 35 x 46.1 SGE060CGA 60 Gas Aluminum 2.4 3600 208 1230 76.8 x 35 x 46.1 SGE060CGS 60 Gas Steel 2.4 3600 208 1283 76.8 x 35 x 46.1 SGE060CPA 60 Liquid Propane Aluminum 2.4 3600 208 1230 76.8 x 35 x 46.1 SGE060CPS 60 Liquid Propane Steel 2.4 3600 208 1283 76.8 x 35 x 46.1 SGN070CGAL 70 Gas Aluminum 6.8 1800 243 2040 97 x 37 x 47 SGN070CPAL 70 Gas Aluminum 6.8 1800 243 2040 97 x 37 x 47 SGN070CGALE 70 Liquid Propane Aluminum 6.8 1800 243 2040 97 x 37 x 47 SGN070CPALE 70 Liquid Propane Aluminum 6.8 1800 243 2040 97 x 37 x 47 SGN080CGA 80 Gas Aluminum 5.4 3600 278 2075 116 x 37 x 55 SGN080CPA 80 Liquid Propane Aluminum 5.4 3600 278 2075 117 x 37 x 55 SGN100CGALE 100 Gas Aluminum 6.8 2300 347 2075 118 x 37 x 55 SGN100CPALE 100 Liquid Propane Aluminum 6.8 2300 347 2075 119 x 37 x 55 SGN130CGAE 130 Gas Aluminum 6.8 3600 451 2699 120 x 37 x 55 SGN130CPAE 130 Liquid Propane Aluminum 6.8 3600 451 2699 121 x 37 x 55 SGN150CGAE 150 Gas Aluminum 6.8 3600 520 2492 122 x 37 x 55 SGN150CPAE 150 Liquid Propane Aluminum 6.8 3600 520 2492 123 x 37 x 55 Compatible Transfer Switches SL100C SL200C SL400C SL600C SL800C Residential generators selection & application guide 9 Liquid Cooled Generator Specifications/ Compatible Transfer Switches (cont.) 120/240V 3-Phase Catalog No. kW Rating Fuel Type Enclosure Engine Size (Liters) Speed (RPM) Amp Output Weight (lbs.) Dimensions (in.) SGE022JBAL 22 Both Aluminum 2.4 1800 66 955 62.2 x 30.6 x 38.6 SGE025JBA 25 Both Aluminum 1.5 3600 75 835 62.2 x 30.6 x 38.6 SGE025JBS 25 Both Steel 1.5 3600 75 901 62.2 x 30.6 x 38.6 SGE027JBAL 27 Both Aluminum 2.4 1800 81 955 62.2 x 30.6 x 38.6 SGE030JBA 30 Both Aluminum 1.5 3600 90 865 62.2 x 30.6 x 38.6 SGE030JBS 30 Both Steel 1.5 3600 90 961 62.2 x 30.6 x 38.6 SGE032JBAL 32 Both Aluminum 2.4 1800 96 1271 76.8 x 35 x 46.1 SGE036JBA 36 Both Aluminum 2.4 3600 108 1202 76.8 x 35 x 46.1 SGE036JBS 36 Both Steel 2.4 3600 108 1255 76.8 x 35 x 46.1 SGE038JBAL 38 Both Aluminum 2.4 1800 114 1271 76.8 x 35 x 46.1 SGE045JBA 45 Both Aluminum 2.4 3600 135 1260 76.8 x 35 x 46.1 SGE045JBAE 45 Both Aluminum 2.4 3600 135 1260 76.8 x 35 x 46.1 SGE045JBS 45 Both Steel 2.4 3600 135 1313 76.8 x 35 x 46.1 SGE045JBSE 45 Both Steel 2.4 3600 135 1313 76.8 x 35 x 46.1 SGE048JBAL 48 Both Aluminum 5.4 1800 144 1555 76.8 x 35 x 46.1 SGE048JBALE 48 Both Aluminum 5.4 1800 144 1555 76.8 x 35 x 46.1 SGE060JGA 60 Gas Aluminum 2.4 3600 180 1230 76.8 x 35 x 46.1 SGE060JGS 60 Gas Steel 2.4 3600 180 1283 76.8 x 35 x 46.1 SGE060JPA 60 Liquid Propane Aluminum 2.4 3600 180 1230 76.8 x 35 x 46.1 SGE060JPS 60 Liquid Propane Steel 2.4 3600 180 1283 76.8 x 35 x 46.1 SGN070JGAL 70 Gas Aluminum 6.8 1800 210 2040 97 x 37 x 47 SGN070JPAL 70 Gas Aluminum 6.8 1800 210 2040 97 x 37 x 47 SGN070JGALE 70 Liquid Propane Aluminum 6.8 1800 210 2040 97 x 37 x 47 SGN070JPALE 70 Liquid Propane Aluminum 6.8 1800 210 2040 97 x 37 x 47 SGN080JGA 80 Gas Aluminum 5.4 3600 249 2075 116 x 37 x 55 SGN080JPA 80 Liquid Propane Aluminum 5.4 3600 249 2075 117 x 37 x 55 SGN100JGALE 100 Gas Aluminum 6.8 2300 301 2075 118 x 37 x 55 SGN100JPALE 100 Liquid Propane Aluminum 6.8 2300 301 2075 119 x 37 x 55 SGN130JGAE 130 Gas Aluminum 6.8 3600 391 2699 120 x 37 x 55 SGN130JPAE 130 Liquid Propane Aluminum 6.8 3600 391 2699 121 x 37 x 55 SGN150JGAE 150 Gas Aluminum 6.8 3600 451 2492 122 x 37 x 55 SGN150JPAE 150 Liquid Propane Aluminum 6.8 3600 451 2492 123 x 37 x 55 Compatible Transfer Switches SL100J SL200J SL400J SL600J SL800J 10 Residential generators selection & application guide Liquid Cooled Generator Specifications/ Compatible Transfer Switches (cont.) 277/480V 3-Phase Catalog No. kW Rating Fuel Type Enclosure Engine Size (Liters) Speed (RPM) Amp Output Weight (lbs.) Dimensions (in.) SGE032IBAL 32 Both Aluminum 2.4 1800 48 1271 76.8 x 35 x 46.1 SGE036IBA 36 Both Aluminum 2.4 3600 54 1202 76.8 x 35 x 46.1 SGE036IBS 36 Both Steel 2.4 3600 54 1255 76.8 x 35 x 46.1 SGE038IBAL 38 Both Aluminum 2.4 1800 57 1271 76.8 x 35 x 46.1 SGE045IBA 45 Both Aluminum 2.4 3600 68 1260 76.8 x 35 x 46.1 SGE045IBAE 45 Both Aluminum 2.4 3600 68 1260 76.8 x 35 x 46.1 SGE045IBS 45 Both Steel 2.4 3600 68 1313 76.8 x 35 x 46.1 SGE045IBSE 45 Both Steel 2.4 3600 68 1313 76.8 x 35 x 46.1 SGE048IBAL 48 Both Aluminum 5.4 1800 72 1555 76.8 x 35 x 46.1 SGE048IBALE 48 Both Aluminum 5.4 1800 72 1555 76.8 x 35 x 46.1 SGE060IGA 60 Gas Aluminum 2.4 3600 90 1230 76.8 x 35 x 46.1 SGE060IGS 60 Gas Steel 2.4 3600 90 1283 76.8 x 35 x 46.1 SGE060IPA 60 Liquid Propane Aluminum 2.4 3600 90 1230 76.8 x 35 x 46.1 SGE060IPS 60 Liquid Propane Steel 2.4 3600 90 1283 76.8 x 35 x 46.1 SGN070IGAL 70 Gas Aluminum 6.8 1800 105 2040 97 x 37 x 47 SGN070IPAL 70 Gas Aluminum 6.8 1800 105 2040 97 x 37 x 47 SGN070IGALE 70 Liquid Propane Aluminum 6.8 1800 105 2040 97 x 37 x 47 SGN070IPALE 70 Liquid Propane Aluminum 6.8 1800 105 2040 97 x 37 x 47 SGN080IGA 80 Gas Aluminum 5.4 3600 120 2075 116 x 37 x 55 SGN080IPA 80 Liquid Propane Aluminum 5.4 3600 120 2075 117 x 37 x 55 SGN100IGALE 100 Gas Aluminum 6.8 2300 150 2075 118 x 37 x 55 SGN100IPALE 100 Liquid Propane Aluminum 6.8 2300 150 2075 119 x 37 x 55 SGN130IGAE 130 Gas Aluminum 6.8 3600 195 2699 120 x 37 x 55 SGN130IPAE 130 Liquid Propane Aluminum 6.8 3600 195 2699 121 x 37 x 55 SGN150IGAE 150 Gas Aluminum 6.8 3600 225 2492 122 x 37 x 55 SGN150IPAE 150 Liquid Propane Aluminum 6.8 3600 225 2492 123 x 37 x 55 Compatible Transfer Switches SL100I SL200I SL400I SL600I SL800I Residential generators selection & application guide 11 Generator Ready Load Center NOTE: GENTFRSWTCH is sold separately from Gen ready panel! The Siemens Generator Ready Load Center can save thousands of dollars in future generator installation expenses while keeping initial expenses to a minimum. Works with an automatic standby generator or a portable generator. Catalog No. ECSBPK01 (mechanical interlock for manual or portable generation installation) GENTFRSWTCH (auto transfer switch for automatic standby generation installation) Automatic Transfer Switch features: UL Listed Operates automatically when connected to generator Transfers load from utility to generator and back to utility Includes: Q215 and Q2125S needed for installation Features: NEMA 3R / Indoor Type 1 225A max rated Flush or surface mounting Fits between standard stud centers Tin plated copper bus bars 22 kAIC rated 120/240V, 1 Phase Main lug – convertible to main breaker with addition of MBK150A, MBK200A, or MBK225A Installation of transfer mechanism can be performed at time of generator installation A E F S S D A 12 B Generator Ready Load Center with Automatic Standby generator installation Residential generators selection & application guide D C B Traditional Installation F E C Generator Ready Load Center with Portable Generator installation Generator Ready Load Center (cont.) 200A Main Breaker Indoor enclosure - NEMA Type 1 Outdoor enclosure - NEMA Type 3R Dimensions (inches) Dimensions (inches) Brand One inch spaces* Max circuits* Catalog No. Height Width Depth Catalog No. Height Width Depth Siemens 30 42 G3042B1200GEN 42.00 14.25 4.00 W3042B1200GEN 42.00 14.63 4.00 Murray 30 42 LC3042B1200GEN 42.00 14.25 4.00 LW3042B1200GEN 42.00 14.63 4.00 225A Main Lug Indoor enclosure - NEMA Type 1 Outdoor enclosure - NEMA Type 3R Dimensions (inches) Dimensions (inches) Brand One inch spaces* Max circuits* Catalog No. Height Width Depth Catalog No. Height Width Depth Siemens 30 42 G3042L1225GEN 42.00 14.25 4.00 W3042L1225GEN 42.00 14.63 4.00 Murray 30 42 LC3042L1225GEN 42.00 14.25 4.00 LW3042L1225GEN 42.00 14.63 4.00 *2 spaces & 2 circuits are reserved for standby generator installation. Install ECSBPK01 for portable generators Install GENTFRSWTCH for automatic standby generators NOTE: GENTFRSWTCH is sold separately from Gen ready panel! G3042L1225GEN Residential generators selection & application guide 13 Portable Generators 5.5, 6.5, 7.5, 8, 15, 17.5 kW Features and ratings Ideal for residential emergency and job-site power Gasoline powered, OHV engine Include handles and wheels for easy movement Hour meter included Large variety of outlets Low noise muffler 2 year residential warranty Easily integrated into home electrical systems with Siemens breaker interlock kits (pictured below) PG0055 PG0065 PG0075Ea PG0080Ea PG015a PG017a Rated Power 5.5 kW 6.5 kW 7.5 kW 8 kW 15 kW 17.5 kW Surge 6.875 kW 8 kW 9.37 kW 10 kW 22.5 kW 26.2 kW Rated Amps @ 60Hz 120/240, 1Ø, 1.0 pf 22.9 27.1 31.2 33.3 62.5 73 Engine RPM 3600 3600 3600 3600 3600 3600 Fuel Capacity (gallons) 6.6 6.6 8 8 16 16 Dimensions (inches) 34 x 26.5 x 27.5 34 x 27 x 28 28.75 x 26.75 x 26 34 x 27 x 28 39 x 31 x 49 39 x 31 x 49 Weight (lbs) 180 172 201 192 450 475 a Manual Electric Starter Portable Accessories: 5715 - Lifting Beam Kit; 6.5 kW & 8.0 kW Refer to page 12 for Portable Maintenance Kits 14 Residential generators selection & application guide Load Centers Manual Transfer Interlock Kits for Load Centers and Meter Combinations Convert load centers or meter combinations into standby power panels Standard features UL listed for use in most Siemens load centers and meter combinations Panels in which the bussing or wire forms from the meter socket land on main lugs are not acceptable for use in standby systems because turning the main breaker to “OFF” does not prevent feedback to the utility power lines. Examples of such panels include catalog numbers that start with the following letters. MC0606L1200* Standby power main breaker Utility main breaker MM0406L1* MC1212L1200* Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code Corrosion resistant finish Easy assembly requiring no Wire forms or bussing modifications to the load center or meter combination To activate standby power the utility main breaker must be in the “OFF” position to prevent dangerous feedback between the power sources. Remains attached to the main breakers when load center cover Acceptable usage of Interlock Kits by load center/meter combination catalog numbers ES Series Load Centers can utilize interlock kits: 1, 2, 5, 6, 7. Kits 3 and 4 can also be used on main breaker panels. Siemens Meter Combinations MC0816B1150RTH 5 7 MC2040B1200 5 7 MC0816B1150T 5 7 MC2040B1200R 5 7 MC0816B1150TH 5 7 MC2442B1200FEC 2 MC0816B1200FCTM 2 MC2442B1200SEC 2 MC0816B1200RT 5 7 MC3040B1200SECW 5 MC0816B1200RTB 5 7 MC3042B1200FED 3 MC0816B1200RTH 5 7 MC3042B1200SED 3 MC0816B1200SCTM 2 MC3042B1225FED 3 MC0816B1200T 7 MC3042B1225SED 3 MC0816B1200TH 5 7 MC4040B1200SECW 5 MC0816B1350RLTM 5 7 MC0816B1200RJBT 8 MC0816B1400RLTM 5 7 MC0816B1150RJBT 8 MC1224B1100FEC 2 MC0816B1200RCT 8 MC1224B1100SEC 2 MC0816B1150RCT 8 MC1224B1125 1 MC0816B1200CT 8 MC1224B1125FEC 2 MC0816B1150CT 8 When used in horizontal positions as typical in most load centers, ECSBPK07 is recommended for use only with QNR type circuit breakers. MC1224B1125SEC 2 MC2040B1150RCT 9 MC1632B1100SEC 2 MC2040B1150CT 9 Standby power interlock kits are not intended for use with AFCI, GFCI, 3-pole or 1/2” frame circuit breakers and 4 space, 125 amp load centers. MC1632B1125FEC 2 MC2040B1200RCT 9 MC2040B1150 5 MC2040B1200CT 9 PL Series Load Centers can utilize interlock kits: 1, 2, 3, 4, 5, 6, 7. Numbers 1 through 9 in these tables represent the last digit in each interlock kit catalog number. Example: 1 = ECSBPK01 2 7 7 7 Siemens type EQ load centers using a “4-pole” main breaker do not have a kit available to interlock this main to branch circuits. Branch circuit positions can be interlocked. Residential generators selection & application guide 15 Manual Transfer Interlock Kits a Prevents dangerous feedback between two sources of power Usage Information Utility Main Breaker Types Standby Main Breaker Types Interlock Number ECSBPK01 For use on load centers or meter combinations that will accept 2-pole circuit breakers opposite one another as shown. QP, QPH, HQPH QP, QPH, HQPH 1 ECSBPK02 For use on load centers or meter combinations that will accept 2-or 4-pole next to a 2-pole circuit breaker side by side as shown. QP, QPH, HQPH QP, QPH, HQPH 2 ECSBPK03b For use on Ultimate™ and Rock Solid load centers, 150 amp and higher, to connect the main breaker to a 2-pole circuit breaker. MBK150A, MBK200A, OR MBK225A QP, QPH, HQPH 3 ECSBPK04 For use on Ultimate™ and Rock Solid load centers, 125 amp and lower, to connect the main breaker to a 2-pole circuit breaker. MBK100A or MBK125A QP, QPH, HQPH 4 ECSBPK05 For use on load centers or meter meter combinations that will accept a QNR (MD-TR) frame circuit breaker next to a 2-pole circuit breaker as shown. QNR, QNRH, HQNR QP, QPH, HQPH 5 ECSBPK06b For use on load centers or meter combinations that will accept a QN (MD-T) frame circuit breaker next to a 2-pole circuit breaker as shown. QN, QNH, HQN QP, QPH, HQPH 6 ECSBPK07 For use on load centers or meter combinations that will accept two QNR (MD--TR) circuit breakers side by side as shown OR will accept two QN (MD-T) circuit breakers side by side as shown. QNR, QNRH, HQNR, QN, QNH, HQN QNR, QNRH, HQNR QN, QNH, HQN 7 ECSBPK08b For use on 8 space, over/under, OH/UG feed meter combinations as shown. Limited application to specific catalog numbers. QPP, QPPH QP, QPH, HQPH 8 ECSBPK09b For use on 20 space, over/under, OH/UG feed meter combinations as shown. Limited application to specific catalog numbers. QPP, QPPH QP, QPH, HQPH 9 Catalog No. a Manual breaker interlock kits are attached to the breakers not the trim of the load center. b This interlock kit takes up 2 spaces adjacent to the 2-pole breaker being interlocked. Those spaces cannot accommodate filler plates. 16 Residential generators selection & application guide Standby Generator Ratings / Maintenance Kits Generator Ratings kW Rating (LP/NG) Rated Amps Engine RPM at full load Natural gas fuel consumption (ft^3/hr) Liquid propane vapor consumption N(gal/hr) Propane vapor consumption ft^3/ft Sound level at normal load Sound level at exercise 8/7 35 3600 118.9 1.47 51.4 62 N/A 11/10 50 3600 160.3 2.08 72.7 63 N/A 16/16 65 3600 312 3.57 130 66 60 20/18 90 3600 303.4 3.99 139.5 66 60 22/19.5 100 3600 281 3.68 127 67 58 for Btu content, multiply ft^3/hr x 2520 (LP) or ft^3/hr x 1000 Oil and Air Filter Kits ASGE ASGN Catalog No. Usage Catalog No. Usage GENMKIT19 8 kW 410cc GENMKIT10 8 kW 410cc GENMKIT20 11 kW 530cc GENMKIT2 10 kW 530cc GENMKIT21 14,16 kW 992cc GENMKIT3 14, 17 kW 990cc GENMKIT22 20, 22 kW 999cc GENMKIT11 20 kW 990cc PORTMKIT1 Portable 15, 17.5 kW PORTMKIT2 Portable 5, 6.5 kW PORTMKIT3 Portable 8 kW Maintenance Kits Just like an engine in an automobile, generator engines require routine maintenance. Service kits, which include oil and air filters, are available and are selected based on engine size. Touch up paint is also provided to help cover minor scratches. Accessories Catalog No. Usage Battery* 525cca group 26R 5621 Auxiliary Transfer Switch Contact GENPAINT Gray Touch Up Paint for 2007 units GENPAINT2 Generator Spray Paint Gray Textured GENSHELL2 Display Shell, gray color 6212 Air Cooled Cold Weather Kit 6186 PMM Module 6199 PMM Starter Kit 6873 Smart Management Module - load management system that operates autonomously 6424 Brown Out Kit 5951 The Wireless Generator Monitoring System provides remote monitoring capability for convenient indoor observation. By adding this item, a generator owner can observe generator function, set certain operation parameters and receive maintenance reminders. Advanced Wireless Remote in Home Monitor 5928 Standard Wireless Remote in Home Monitor GENCART The Generator Transport Cart is designed to allow a single individual to move and position any of the air-cooled generators without the need for additional people or equipment. By attaching the cart to the generator through the lifting holes, the generator is lifted from the pallet by leverage and is easily wheeled to the appropriate location for final setting 5666 The pad skirt snaps together around the bottom of the new 20kW generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. Available in grey, the pad skirt fits 20kW generators manufactured after 4/2008. 6510 E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. * Not included Residential generators selection & application guide 17 Mobile Link Cellular remote monitoring system for your generator 6463 – Mobile Link 6478 – Liquid-Cooled Extension Cable Note: this cable is required with Mobile Link for all liquid-cooled units. Compatibility: Mobile Link is designed for use with a generator equipped with an LCD display. Mobile Link is compatible with most 2008-and-newer air-cooled standby generators and 2010-and-newer liquid-cooled standby generators. Note: Please ensure you have cellular service in your area before purchasing. Email or Text Notifications: StandbyStatus.com provides over 40 different notifications, including successful exercise, maintenance reminders, change in status, low battery, fault alert and more: When maintenance is required or fault conditions occur, StanbyStatus.com automatically sends out alerts Dealer gets accurate data and can respond quickly and efficiently to problems Customers designate up to 4 different accounts to receive email and text notifications, including their dealer, so that they can discuss options with the customer to address the generator’s issues. Notifications drive regular, timely communication with the customer StandbyStatus.com: StandbyStatus.com features a user-friendly dashboard that allows the customer to check their generator’s status anytime, anywhere: View current generator status and upcoming maintenance needs Remotely set exercise schedule Review run and maintenance history Get local weather updates Change messaging settings How does it work? 18 Residential generators selection & application guide 8QLW6WDWXV %DWWHU\9ROWDJH )UHTXHQF\+] Fuel Pipe Sizing Natural Gas Pipe sizing kW 0.75” 1” 1.25” 8 55’ 150’ 600’ 11 20’ 65’ 250’ 1.5” 2” 2.5” 3” 500’ 16 20’ 100’ 200’ 20 20’ 100’ 200’ AC 22 20’ 100’ 200’ LC 22 15’ 115’ 260’ 799’ 25 10’ 95’ 175’ 575’ 27 80’ 450’ 552’ 30 60’ 125’ 450’ 32 60’ 125’ 450’ 36 35’ 95’ 370’ 915’ 38 35’ 95’ 370’ 915’ 45 15’ 60’ 260’ 650’ 48 50’ 230’ 585’ 60 25’ 145’ 375’ 1100’ 70 5’ 75’ 225’ 710’ 80 65’ 195’ 630’ 100 40’ 140’ 460’ 130 50’ 215’ 150 30’ 150’ 2.5” 3” Liquid Propane Pipe Sizing kW 0.75” 1” 1.25” 8 165’ 450’ 11 70’ 300’ 900’ 16 20’ 70’ 350’ 20 15’ 50’ 250’ AC 22 15’ 50’ 250’ 85’ 365’ LC 22 1.5” 25 60’ 275’ 605’ 27 55’ 260’ 575’ 30 40’ 195’ 435’ 32 40’ 195’ 435’ 36 20’ 125’ 290’ 38 20’ 2” 1030’ 125’ 290’ 1030’ 45 82’ 195’ 725’ 48 70’ 165’ 620’ 60 45’ 115’ 445’ 1095’ 70 20’ 60’ 260’ 660’ 80 15’ 50’ 230’ 590’ 30’ 100 165’ 430’ 1305’ 130 70’ 205’ 660’ 150 45’ 150’ 490’ *pipe lengths denoted are in max feet usable Residential generators selection & application guide 19 Notes 20 Residential generators selection & application guide Notes Residential generators selection & application guide 21 Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com www.usa.siemens.com/generators Subject to change without prior notice Order No.: RPSA-GEN02-0815 All rights reserved Printed in USA © 2015 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.