Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Contactors Accessories Optional accessories SZ-AS1T auxiliary contact block SC-E Contactor SZ-Z coil surge suppression unit SZ-AS1T auxiliary contact block SZ-A22T auxiliary contact block Auxiliary contact blocks with terminal covers Maximum auxiliary contact blocks: 2 side mounted (1 per side) OR 1 front mounted. The front and side blocks cannot be mounted together on the same contactor. SZ-A22T SZ-A11T SZ-AS1T SZ-AS2T Auxiliary Contact Blocks with Terminal Covers Caution on use: Part Number Price 1. Front mounting auxiliary contact block and side mounting block cannot be attached to one contactor at the same time. SZ-A22T $12.50 SZ-A20T $8.00 2. Only one front mounting block can be attached to one contactor. 3. Where interlock unit is already attached, side mounting auxiliary contact block can be attached on one side only. SZ-A11T $8.00 SZ-AS1T $12.50 SZ-AS2T $12.50 Applicable Contactor Mounting Number of Contact Contacts Arrangement 4 SC-E02(G)-xxx to E4(G)-xxx Front mounting SC-E02(G)-xxx to E4(G)-xxx SC-E5, E6, E7-xxx, SC-N4, N5, Side mounting N6, N7, N8, N10, N11, N12, SC-E5(G)-xxx to E7(G)-xxx 2 2NO + 2NC 2NO 1NO + 1NC 2 1NO + 1NC 2 1NO + 1NC Accessory Auxiliary Contact Ratings - UL and CSA NEMA ICS 5-2000 Ratings ( note 1 ) AC Ratings Designation A600 DC Ratings Making VA 7200 Breaking VA 720 Designation Q300 Making/Breaking VA 69 For more information, refer to Control Circuit Contact Electrical Ratings, page 17-116 Accessory Auxiliary Contact Ratings - IEC and JIS continued on next page. Book 2 (14.3) eMS-40 Motor Controls 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Contactors Accessories Company Information Drives Soft Starters Accessory Auxiliary Contact Ratings - IEC and JIS Rated Thermal Current (A) Making and Breaking Capacity AC at AC (A) Voltage 10 Motors Rated operational current (A) DC AC-15 (Ind. load) Voltage DC-13 (Ind. load) 120V 60 120V 6 24V 3 220V 30 220V 3 48V 1.5 440V 15 440V 1.5 110V 0.55 600V 12 600V 1.2 220V 0.27 Minimum Operating Voltage and Current Power Transmission Motion: Servos and Steppers Motor Controls 5VDC, 3mA Sensors: Proximity Sensors: Photoelectric Coil surge suppression units SZ-Z1 Coil Surge Suppression Units SZ-Z37 Suppress surge voltage due to contactor ON-OFF operations; easily connect to contactor coil terminals. Important: When driving 24VDC Fuji contactors with a PLC solid-state output, we recommend using diode terminal block part number DN-D10DR-A or ZL-TSD8-24. Please see application note AN-MISC-027 for additional information located on Automationdirect.com/technotes. Sensors: Encoders Part Number Price SZ-Z1 $10.00 SZ-Z2 $10.00 SZ-Z31 $13.50 SZ-Z32 $13.50 SZ-Z4 $11.50 SZ-Z5 $11.50 SZ-Z34 $13.50 SZ-Z35 $13.50 SZ-Z36 $13.50 SZ-Z37 $13.50 Applicable Contactor AC Operated Operating Coil Device Voltage DC Operated SC-E02-xxx to E05-xxx SC-E02G-xxx to E05G-xxx 24-48V AC/DC 100-250V AC/DC 24-48V AC/DC SC-E1-xxx to -E4xxx SC-E1G-xxx to E4G-xxx 100-250V AC/DC SC-E02-xxx to E05-xxx SC-E02G-xxx to E05G-xxx 100-250V AC/DC SC-E1-xxx to E4-xxx - - SC-E1G-xxx to E4G-xxx Varistor 24-48V AC/DC capacitor / resistor SC-E1 to E4 380-440V AC/DC Stacklights Signal Devices Note: Super Magnet Coils on SC-E5, SC-E6, and SC-E7 contactors have internal surge suppression. See diagram below. IC-circuit Power supply AC or DC Surge suppression circuit Voltage detector INPUT Rectifier circuit Pneumatics: Air Prep COIL Pneumatics: Directional Control Valves Sealing signal circuit Pneumatics: Cylinders Replacement contactor coils Pneumatics: Tubing SC-E Series Replacement Contactor Coils Part Number SZ-GSN5-100 Process Relays and Timers Power switching circuit Closing signal circuit Sensors: Flow Pushbuttons and Lights 100-250V AC/DC 380-440V AC/DC Sensors: Pressure Sensors: Level 24-48V AC/DC SC-E02 to E05 Sensors: Current Sensors: Temperature 24-48V AC/DC 100-250V AC/DC Sensors: Limit Switches Price Applicable Contactor Coil Voltage SZ-GSN5-100 $120.50 SC-E5-xxx 100-127VAC 50/60Hz / 100-120VDC SZ-GSN6-100 $132.50 SC-E6-xxx, SC-E7-xxx 100-127VAC 50/60Hz / 100-120VDC SZ-GSN5-200 $120.50 SC-E5-xxx 200-250VAC 50/60Hz / 200-240VDC SZ-GSN6-200 $132.50 SC-E6-xxx, SC-E7-xxx 200-250VAC 50/60Hz / 200-240VDC SZ-GSN5-24 $120.50 SC-E5-xxx 24-25VAC/ 50/60Hz / 24VDC SZ-GSN6-24 $132.50 SC-E6-xxx, SC-E7-xxx 24-25VAC/ 50/60Hz / 24VDC Replacement coils are available for contactor sizes SC-E5 and larger only. Replacement coils are not available for coil codes 440VAC, 500VAC, 400V, 500V. Book 2 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l s Motor Controls eMS-41 Pneumatics: Air Fittings Appendix Book 2 Terms and Conditions Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Accessories Connection kits for reversing SC-E contactors SZ-ERW1A Line Side Wiring SZ-ERW1B Load Side Wiring SZ-ERW2D Load Side Wiring SZ-ERW2A SZ-ERW1D Load Side Wiring Line Side Wiring Load Side Wiring Line Side Wiring SZ-ERW3D SZ-ERW3B SZ-ERW3A SZ-ERW2B Load Side Wiring Load Side Wiring Connection Kits Part Number Price Description SZ-ERW1A $4.50 Line side reversing connection kit. Use with Contactors SZ-ERW1B* $4.50 Load side reversing connection kit. For wiring load side when using contactors only or with a MMS device. SZ-ERW1D $4.50 Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. SZ-ERW2A $10.00 Line side reversing connection kit. SZ-ERW2B* $10.00 Load side reversing connection kit. For wiring load side when using contactors only or with a MMS device. SZ-ERW2D $10.00 Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. SZ-ERW3A $18.50 Line side reversing connection kit. SZ-ERW3B* $18.50 Load side reversing connection kit. For wiring load side when using contactors only or with a MMS device. SZ-ERW3D $18.50 Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. SC-E02-xxx to SC-E05-xxx SC-E1-xxx to SC-E2S-xxx SC-E3-xxx to SC-E4-xxx * When using the SZ-ERWxB, a TK-E thermal overload relay must be separately mounted and wired using an SZ-HxE base. To assemble a TK-E overload directly to the contactor use a SZ-ERWxD load side connection kit. Mechanical interlock unit Mechanical Interlock Unit Part Number Price Description SZ-RM SZ-RM when building a reversing starter. Prevents both contactors $12.50 Used from being pulled in at once. Use with Contactors SC-E02-xxx to SC-E4-xxx NOTE: Mechanical interlock unit cannot be used with SC-E5-xxx through E7-xxx contactors. Parts for reversing Fuji SC-E contactors Book 2 (14.3) • • • • • eMS-42 SC-E (Contactors - qty. 2) SZ-ERWxA (Line side connection kit - qty. 1) SZ-ERWxB* (Load side connection kit - qty. 1) SZ-RM (Mechanical interlock - qty. 1) SZ-AxxT (Auxiliary contact blocks - qty. 1) Motor Controls 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Contactors Company Information Drives Soft Starters Dimensions (mm) Motors Contactors Power Transmission SC-E1G, E2G, E2SG-xxx Coil terminal M3.5 45(38 to 46) Motor Controls 9.5 5 54 Sensors: Proximity 2 80 75 (79) *1 18.5 Main terminal Sensors: Photoelectric 1 *1 Mounting hole 2-M4 16.5 *2 Weight: 0.79 kg Mass: 0.79kg Motion: Servos and Steppers Panel drilling (28) *2 57 90 130 (Rail height 15) 121.5 91 10.5 2 Sensors: Encoders 45 Sensors: Limit Switches Use the two mounting holes on a diagonal line or to mount contactor : 45 75 : 45 (38 to 46) 80 *1 Side mounting aux. contact block *2 Front mounting aux. contact block Sensors: Current SC-E3G, E4G-xxx Panel drilling (28) *2 (91) * 67 1 Coil terminal M3.5 Sensors: Pressure (54 to)60 Sensors: Temperature 13 Main terminal 19.5 140 (Rail height 15) 130 91.5 10.5 2.5 Sensors: Level 90 77 112 2 1 *1 *2 Weight: 1.4 kg Mass: 1.4kg 20.5 *1 Side mounting aux. contact block *2 Front mounting aux. contact block Mounting hole 2-M4 Sensors: Flow (55 to)60 Pushbuttons and Lights Use the two mounting holes on a diagonal line or to mount contactor : (55 to) 60 90 : (54 to) 60 90 Stacklights Dimensions-mm Wiring diagrams Auxiliary contact blocks - front mounting SZ-A22T, A20T, A11T SZ-A22T, A20T, A11T for SC-E02 (G)-xxx to E4 (G)-xxx C 5 11 Approx 25 3 Approx 3 M3.5 7.7 10 43 A22T SZ-A20T , A11T A A Relays and Timers 54 64 Pneumatics: Air Prep Pneumatics: Directional Control Valves B B 53 61 28 49 28 49 M3.5 7.7 1NO+1NC 10 24 Mass: 36g Weight: 36 g Mass: 20g Weight: 20 g 54 62 Pneumatics: Cylinders 53 61 71 83 Pneumatics: Tubing 54 62 72 84 Pneumatics: Air Fittings 2NO+2NC Type SC-E02, E03, E04, E05-xxx SC-E1, E2, E2S-xxx SC-E3, E4-xxx A 43 54 67 B 80 90 112 C 109 124 139 SC-E02G, E03G, E04G, E05(G)-xxx SC-E1G, E2G, E2SG-xxx SC-E3G, E4G-xxx 43 54 67 80 90 112 136 149.5 158 Appendix Book 2 Terms and Conditions Book 2 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l s Process 53 63 2NO Contactor with aux. contact block Signal Devices Motor Controls eMS-45 Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Contactors Dimensions (mm) Wiring diagrams Auxiliary contact blocks - side mounting SZ-AS1T for SC-E02(G)-xxx to E4(G)-xxx 1 N.O. + 1 N.C. Contactor with aux. contact block C 12 M3.5 A D Mounted on right side 71 83 12 45 7.7 Weight: 28 g Mass: 28g B 59.5 43 28 72 84 Mounted on left side 12 53 61 7.5 Type SC-E02, E03, E04, E05-xxx SC-E1, E2, E2S-xxx SC-E3, E4-xxx A 67 78 91 B 80 90 112 C 81 54 67 SC-E02G, E03G, E04G, E05(G)-xxx SC-E1G, E2G, E2SG-xxx SC-E3G, E4G-xxx 67 78 91 80 90 112 108 43 121.5 54 130 67 D 43 54 67 54 62 SZ-AS2T for SC-E5 to E7-xxx Contactor with aux. contact block C A D 12 12 1 N.O. + 1 N.C. Mounted on right side 71 83 M3.5 B 64.5 47 28 72 84 Mounted on left side 53 61 7.7 47.5 12 7 Weight:40g 40 g Mass: 54 62 Type A B C SC-E5-xxx 112 155 132 88 SC-E6-xxx 124 169 138 100 SC-E7-xxx 139 175 140 115 D Book 2 (14.3) eMS-46 Motor Controls 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of October 21, 2015. Check Web site for most current prices. Fuji Duo Series SC-E Contactors Company Information Drives Dimensions (mm) Wiring diagrams Coil surge suppression units Soft Starters Motors Power Transmission SC-E02 to E05-xxx + SZ-Z1, Z2 (Built-in varistor) SZ-Z1, Z2, Z4, Z5 Motion: Servos and Steppers Motor Controls Sensors: Proximity Sensors: Photoelectric SC-E02 to E05-xxx + SZ-Z4, Z5 (Built-in capacitor/resistor) Sensors: Encoders Sensors: Limit Switches C R Sensors: Current Weight: 14 g Sensors: Pressure SC-E1 to E4-xxx + SZ-Z31, Z32 SZ-Z31, Z32, Z34, Z35, Z36, Z36, Z37 (Built-in varistor) Sensors: Temperature Sensors: Level Sensors: Flow Pushbuttons and Lights SC-E1 to E4-xxx + SZ-Z34, Z35 (Built-in capacitor/resistor) SC-E1G to E4G-xxx + SZ-Z36, Z37 (Built-in capacitor/resistor) Weight: 15 g C Stacklights Signal Devices Process Relays and Timers R Pneumatics: Air Prep Pneumatics: Directional Control Valves SZ-RM Pneumatics: Cylinders Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2 Terms and Conditions Book 2 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l s Motor Controls eMS-47