LED LIGHTING POWER CONVERTER LED LIGHTING POWER CONVERTER UNIVERSAL LED LIGHTING POWER CONVERTER Product Features · Active power-factor compensation circuits is built-in · Excellent quality and durability · Prevent the risk of fire by avoiding use of explosive components · Unused cooling fan (reduce noise, extend product life cycle) · Capacity of maintaining low temperature due to best heat dissipating system · Replacement cost saving due to excellent durability (50,000hours) · Designed as IP67 to use for indoor and outdoor · Over 90% of high efficiency products · Qualified to Industrial LED lighting and LED street lighting Product Specifications LED LIGHTING POWER CONVERTER MODEL 1 INPUT OUTPUT [48V / 36V / 30V] 60w LPS-FUIN60WXXV-V1 1.12A / 1.50A / 1.80A 70w LPS-FUIN70WXXV-V1 1.31A / 1.75A / 2.10A 80w LPS-FUIN80WXXV-V1 1.50A / 2.00A / 2.40A 90w LPS-FUIN90WXXV-V1 1.69A / 2.25A / 2.70A 100w LPS-FUIN100WXXV-V1 1.87A / 2.50A / 3.00A 120w LPS-FUIN120WXXV-V1 2.25A / 3.00A / 3.60A 150w LPS-FUIN150WXXV-V1 2.81A / 3.75A / 4.50A 200w LPS-FUIN200WXXV-V1 3.75A / 5.00A / 6.00A SHAPE 172*67*39mm 100-277Vac~ 2 3 223*67*39mm Appearance 1 2 3 226*67*39mm LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (60W) Model POWER LPS-FUIN60W48V-V1 LPS-FUIN60W36V-V1 LPS-FUIN60W30V-V1 Output Voltage 48V 36V 30V Rated Current 1.12A 1.50A 1.80A Rated Power 54W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz >0.97/230VAC @100% Load, Power Factor INPUT >0.98/115VAC @100% Load Efficiency(Typ.) 90% / 230VAC 88% / 115VAC AC Current 0.27A/230VAC 0.53A/115VAC Rated Power 60W ±5% Inrush Current 25A/230VAC Leakage Current <0.2㎃/115VAC <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 2.0A 3.0A 3.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 Class B Harmonic Current Compliance to EN6100-3.2 Class C,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (70W) LPS-FUIN70W48V-V1 LPS-FUIN70W36V-V1 LPS-FUIN70W30V-V1 Output Voltage 48V 36V 30V Rated Current 1.31A 1.75A 2.10A Model POWER INPUT Rated Power 63W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 90% /230VAC 88% /115VAC AC Current 0.31A/230VAC 0.62A/115VAC Rated Power 70W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 2.0A 3.0A 3.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (80W) LPS-FUIN80W48V-V1 LPS-FUIN80W36V-V1 LPS-FUIN80W30V-V1 Output Voltage 48V 36V 30V Rated Current 1.50A 2.00A 2.40A Model POWER INPUT Rated Power 72W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 90% /230VAC 88% /115VAC AC Current 0.36A/230VAC 0.71A/115VAC Rated Power 80W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 2.0A 3.0A 3.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (90W) LPS-FUIN90W48V-V1 LPS-FUIN90W36V-V1 LPS-FUIN90W30V-V1 Output Voltage 48V 36V 30V Rated Current 1.69A 2.25A 2.70A Model POWER INPUT Rated Power 81W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 90% /230VAC 88% /115VAC AC Current 0.40A/230VAC 0.80A/115VAC Rated Power 90W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 2.5A 3.5A 4.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (100W) LPS-FUIN100W48V-V1 LPS-FUIN100W36V-V1 LPS-FUIN100W30V-V1 Output Voltage 48V 36V 30V Rated Current 1.87A 2.50A 3.00A Model POWER INPUT Rated Power 90W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 90% /230VAC 88% /115VAC AC Current 0.45A/230VAC 0.89A/115VAC Rated Power 100W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 2.5A 3.5A 4.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (120W) LPS-FUIN120W48V-V1 LPS-FUIN120W36V-V1 LPS-FUIN120W30V-V1 Output Voltage 48V 36V 30V Rated Current 2.25A 3.00A 3.60A Model POWER INPUT Rated Power 108W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 91% /230VAC 88% /115VAC AC Current 0.54A/230VAC 1.06A/115VAC Rated Power 120W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 3.0A 4.0A 5.0A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (150W) LPS-FUIN150W48V-V1 LPS-FUIN150W36V-V1 LPS-FUIN150W30V-V1 Output Voltage 48V 36V 30V Rated Current 2.81A 3.75A 4.5A Model POWER INPUT Rated Power 135W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 91% /230VAC 88% /115VAC AC Current 0.67A/230VAC 1.33A/115VAC Rated Power 150W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 3.5A 4.5A 5.5A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Electrical and Photometric Data Highlights (200W) LPS-FUIN200W48V-V1 LPS-FUIN200W36V-V1 LPS-FUIN200W30V-V1 Output Voltage 48V 36V 30V Rated Current 3.75A 5A 6A Model POWER INPUT Rated Power 180W Line Regulation ±2% Load Regulation ±1% Voltage Range 100 ~ 277VAC Frequency Range 47 ~ 63Hz Power Factor >0.97/230VAC @100% Load, >0.98/115VAC @100% Load Efficiency(Typ.) 91% /230VAC 88% /115VAC AC Current 0.90/230VAC 1.78A/115VAC Rated Power 200W ±5% Inrush Current 25A/230VAC <0.2㎃/115VAC Leakage Current <0.4㎃/230VAC ETC Over Current PROTECTION Short Circuit Over Voltage ENVIROMENT SAFETY & EMC 4.5A 6A 7A Hiccup mode, recovers automatically after fault condition is remove 54~60V 41~46V 41~46V Operating Temperature -35℃ ~ 60℃ (Refer to output load derating curve) Operating Humidity 20 ~ 90% RH Storage Temperature , Humidity -40 ~ 80℃, 10 ~ 95% RH Safety Standards EN61347-1, EN61347-2-13, IP67 approved EMI Compliance to EN55015, EN55022 ClassB Harmonic Current Compliance to EN6100-3.2 ClassC,, EN6100-3-3 EMS Immunity Compliance to EN6100-4-2,3,4,5,6,8,11, EN61547 LED LIGHTING POWER CONVERTER Pre-Installation Checklist products Identification of Input Power - Verify ballasts and input power - Verify if input power is supplied constantly Check for leakage of electricity and grounded - Check for short circuit in case of rainfall and snowfall - Check grounding of lighting fixture and ballast Ambient Temperature - Recommended Service Temperature: ordinary temperature - Ordinary temperature : -20 ℃ ~ 60 ℃ Condition of Lighting Fixture - Do not use sealed lighting equipment - Confirm product contents and use specified products only - Do not use if short circuit occurs caused by crack near socket connection (welding & coupling) or lampshade ※ Products that are damaged as a result of external causes, conditions demonstrating misuse, improper installation, not following instructions, improper or inadequate maintenance, accident, or tampering are excluded under the warranty. LED LIGHTING POWER CONVERTER Precautions Please follow above installation instruction and install accurately -Products that are damaged due to improper installation is excluded under the warranty. Do not use in power supply other than a frequency tolerance and the rated power – It may result in fire and equipment damage. Do not operate at lighting fixture or circuit which has dimming function – It may result in fire and equipment damage. Avoid unstable locations when installing the equipment – It may result in failure from falling Do not operate the equipment outside -20 ~ 50℃ range of ambient temperatures – It may result in fire and failure If the equipment is installed when the ambient temperature is high, pay attention to ventilation of the equipment – It may result in fire and shortening product life cycle Do not repair, remodel, disassemble arbitrarily without following instructions – It may result in safety accident and failure Do not drop, giving a shock, applying force, and scratch. – It may result in failure Do not touch a lamp while it is on, and after lights-out within the next few minutes – It may result in burns and injuries Do not use surrounding a wet or humid environment – It may cause injuries by defective insulation, fall, etc. It may cause noise when lights-on near audio and video devices, such as Radio, TV – When noise occurs, move electric device over 1m (3ft) from the lighting equipment Do not spray chemical on the lamp – It may result in discoloration and deterioration Do not seal the lighting equipment or covered by a painting – It may cause of overheating, and it can lead to fire and injuries Do not use it near combustible/inflammable material, such as gasoline, acid, etc. – It may cause corrosion, shortening product life cycle, and it may leads to fire and explosion Making frequent flickering may result in shortening product life cycle LED LIGHTING POWER CONVERTER Certification Conduction Noise : CE CLASS (B) -3dB Radiation Noise : CE CLASS (B) -3dB Vibration Resistant : Power supply normally operated without breakage after Vibration test 1) FREQUENCE :5 => 60 => 5 Hz 2) ACCELERATION : 0.5 G 3) Direction : X, Y, Z 4) Operating Time : 3 minutes POWER ON/OFF TEST : Power supply requires On/Off switching test over a 1,000 times on minimum input, normal load, and maximum output SURGE TEST Do not have any breakage, ignition and fuming when it is applied 5 times of ±3KV to between L1-L2 Do not have any breakage, ignition and fuming when it is applied 5 times of ±6KV to between L1(L2)-F.G ESD TEST There should be no problem when following electrostatic noise is applied by condenser emission method Condition : ⓐ Applied Voltage : Air ±15KV, Contact ±8KV ⓑ Applied number : 10 ⓒ Capacitance: 150pF ⓓ Discharge Resistance: 330Ω ⓔ Interval : 1 sec 1 second Leakage Current When measuring between Live and 2nd GND, between Neutral and 2nd GND with input impedance meter of 1KΩ with rated Input and no load condition, it requires below 0.5mA Insulation Resistance The product requires above 100MΩ of insulation resistance of input and output sides when it applied DC500V. At this time, measure input and output terminal, each tied separately High Pot or Withstand Voltage The product should be no problem when it is applied 3KV AC power (Cutoff Current 10mA) to input and output sides for 1 minute [3.7KV/1sec.] LED LIGHTING POWER CONVERTER Certification