Wenzel Associates, Inc. "Quietly the Best" RF Systems & Synthesizers > Phase Noise Test Sets Residual System Standard Features: BLUE PHASE 1000 Test Active Devices - Amplifiers, Multipliers, Dividers, etc. Test Passive Devices - Cables, Filters, Mixers, Splitters, etc. Frequencies from 5 MHz to 1.5 GHz Noise Floors to <-178 dBc Offsets to 100 kHz Multi-Function Analog Panel Meter Speaker for Noise Monitoring and Troubleshooting USB Port Interface for Computer Control of Instrument TM Residual Phase Noise Test Set BP-1000-RM Additional Plug-Ins and Capabilities: Mixer/LPF for Extended Input Frequencies to 12 GHz Audio Amplifier for Extended Offset Measurements to 20 MHz Voltage Regulator for Clean Auxiliary Power (Front Panel) Built-in or External Reference Source Other Standard Configurations: Single Channel Absolute Phase Noise Measurement System Cross-Correlation Absolute Phase Noise Measurement System BPMS-1000-RM Phase Noise Measurement System SSB Phase Noise <-178 dBc/Hz at 10 kHz (Typical @ 100 MHz) Frequency Range 5 MHz to 1.5 GHz [extended range available] Offset Analysis Measurement Accuracy 1 Hz to 100 kHz [to 20 MHz available] ±1.5 dB (<100 kHz offset) [±2 dB (<20 MHz offset) optional] Input Signal Level Application Dependent Input / Output Connectors SMA female, BNC female Spurious <-110 dBc Supply Voltage +18 /+1 VDC -1 -18 /+0 VDC Supply Voltage Connector D-subminiature 9 pin connector Power Consumption <500 mA @ ±18 VDC ±5%, standard Operating Temperature 0 to +50°C Dimensions (w x d x h) 17.625 x 15 x 5.25 " (3U) [19" rack mountable] -0 BPPS-1000 BluePhase Power Supply Supply Voltage Output Voltage 115/230 VAC, 50/60 Hz [selectable] -0 +18 /+1 VDC, 1.5A -1 -18 /+0 VDC, 1.5A Supply Voltage Connector D-subminiature 9 pin connector Operating Temperature 0 to +50°C Supply Fuse Dimensions (w x d x h) AC: 250V, 1.5 A, slow blow. DC: 250V, 2A, slow blow (internal) 9.25 x 11.5 x 5.25" (3U) [half-rack standard; full-rack available] Standard Test Equipment Required: Phase Shifter Oscilloscope FFT Analyzer (for offsets to 100 kHz) - Recommend: SR760 (for Single Channel) Spectrum Analyzer (for offsets to 20 MHz) Phase Noise Test Set Overview: Wenzel Associates BLUE PHASE 1000TM series test set integrates B LUE T OPSTM modules and other ultra low noise components into a manually operated or computer controlled phase noise measurement system. The B LUE PHASE 1000TM test set is modularly constructed, allowing complete flexibility for use in multiple configurations and achieving extremely low noise floors. The Residual Phase Noise Test Set (BP-1000-RM) consists of a two chassis configuration. The BPMS-1000-RM is the Residual Phase Noise Measurement System, which is housed in a 5¼” high rack mountable chassis. This unit is powered by the BPPS-1000 Low Noise Power Supply, which is housed in a 5¼” high half-rack or full-rack chassis. The BPMS-1000RM phase noise measurement system is configured to facilitate the accurate residual (additive) phase noise measurements of active or passive two-port devices such as amplifiers, multipliers, dividers, splitters, cables and filters as well as mixers. The residual phase noise measurement requires only one frequency source. The signal from this frequency source is first reactively power split. One output of the splitter passes through the device under test (DUT), while the other output passes through a phase shifter. Two DUT’s are required for devices that change the frequency (ie. multipliers, dividers, etc.) The phase shifter is adjusted to put these two signals in quadrature at the input to a mixer. The phase noise from the frequency source is coherent at the inputs to the mixer, and therefore, mostly cancelled. The remaining phase noise present at the mixer output is the residual noise from the DUT1 (and DUT2 if present). The measured voltage variations at the mixer output are easily converted to phase noise by correcting for mixer conversion and amplifier gain. Optional: Computer with a USB communications port running - Microsoft Windows (XP recommended) Crystal Oscillators Wenzel Associates, Inc. 2215 Kramer Lane Austin, Texas 78758-4002 Blue Tops RF Modules RF Systems & Synthesizers www.wenzel.com Military & Space Testing Services sales@wenzel.com Phone: 512-835-2038 Fax 512-719-4086 Wenzel Associates, Inc. "Quietly the Best" RF Systems & Synthesizers > Phase Noise Test Sets BLUE PHASE 1000 TM Residual Phase Noise Test Set BP-1000-RM PHASE NOISE MEASUREMENT SYSTEM BPMS-1000-RM -15 VDC REGULATOR -15V +15V PLL +5 VDC REGULATOR +5V PLL2 RF INPUT ANALOG/DIGITAL INPUT/OUTPUT CTRL BPM-1000 MICROCONTROLLER USB 2.0 INTERFACE BPUSB-1000 COMPUTER USB ISOLATOR POWER SPLITTER REF BLUE PHASE POWER SUPPLY BPPS-1000 USB METER EXT DC INPUT +15 VDC REGULATOR USB SPEAKER OFF PLL PLL2 VOLUME BPSP-1000 BPS-1000 DUT1 LO IN AUDIO AMPLIFIER MIXER/LPF OUT INPUT HIGH Z 50 MHz OUT 1 MHz RF IN BPMX-1000 30 dB DC AC1 AC2 30 dB AC3 CTRL DC-100 kHz OUTPUT LOW Z 0 dB 30/60 dB BPAA-1000 FFT ANALYZER HIGH Z HIGH Z OSCILLOSCOPE DUT2 (Optional) RESIDUAL PHASE NOISE TEST CONFIGURATION Crystal Oscillators Blue Tops RF Modules Wenzel Associates, Inc. 2215 Kramer Lane Austin, Texas 78758-4002 RF Systems & Synthesizers www.wenzel.com Military & Space Testing Services sales@wenzel.com Phone: 512-835-2038 Fax 512-719-4086 60712-