Smart Modules NEED Smart Inverters KACO blueplanet 50.0 TL3 grid-tied inverter KACO new energy is a leader in power electronics specializing in PV inverters, performance monitoring systems, and power supply systems for industrial rail applications. KACO new energy inverters paired with smart modules optimized by Tigo Energy achieve increased performance and lower maintenance costs over the life of the system. Smart modules optimized by Tigo can enable up to 30% longer strings and achieve significant balance of system (BOS) savings. Safer Solar Lower BOS Costs More Efficient O&M Maximized Energy Harvest Highest Power Density Fully Integrated Module-level disconnect remotely deactivates modules providing additional safety and qualifying for new rapid shutdown requirements. Module-level monitoring to pinpoint problems. Detailed real-time alerts and analytics. Install more modules on any roof. Uneven string lengths enables design flexibility. 30% lower max open circuit voltage & longer strings. Fewer combiners, fuses & copper wiring required. Impedance matching mismatch losses. technology eliminates No additional hardware required for rack mounting. blueplanet 50.0 TL3 Model number Energy Yield 97.5% CEC efficiency Safety Compliant with NEC 690 section III for PV system AC & DC disconnection DC Electrical Specifications DC maximum input voltage (VDC) DC maximum peak power operating range (MPP) (VDC) DC operating range (VDC) DC minimum start voltage (VDC) DC maximum operating current (ADC) DC maximum short circuit current per channel (ADC) DC input overload protection 1000 480-850 200-850 250 108 165 Yes / Voltage / Current AC Electrical Specifications AC maximum continuous output power (W) CEC weighted efficiency (%) 50,000 97.5 AC nominal voltage / operating range L to Neutral (VAC) Reliability AC and DC surge protection NEMA 3R construction Operations Integrated AC & DC BOS components Up to 75% lighter than other inverters Integrated web server Graphical user interface Warranties are only as valuable as the strength and longevity of the manufacturer. KACO new energy is one of the few established inverter companies older than the warranties they offer. 480 / 243 to 304 AC continuous output current (A) Frequency nominal / range (Hz) Power factor Total harmonic distortion (%) Standby losses (W) AC input terminals and conductor Utility connection 60 60 / 60.5 to 59.3 > .99 <5 < 1.5 4 / 4-18 AWG AL Cu Wye 4 wire (A, B, C, N) PV System Disconnects - PSD (optional) Integrated AC / DC disconnect AC disconnection means AC disconnection ratings AC overcurrent protection devices (OCPD) Yes Rotary switch visible and accessible from outside of enclosure 100 A VAC Break L1-L2-L3 Current limiting inverter, OCPD provided by system integrator AC LOTO provision AC input terminals / conductor size LOTO in OPEN L1-L2-L3 N PE / 14 AWG - 1/0 Cu DC disconnection means DC disconnection ratings DC LOTO provision Rotary switch accessible from outside of enclosure 200 A breaking positive and negative LOTO in OPEN DC input terminals / conductor size, per channel 1 Pos and 1 Neg / 4 AWG - 300 kcmil Cu Mechanical and Environmental Specifications Mounting Unit weight (lbs/kg) Ground mount, roof mount 381 / 173 Unit dimensions HxWxD (in/mm) 53.5 x 33 x 14 / 1360 x 840 x 355 Operating temperature range (°F / °C) (-13 to 140 / -25 to 601) Storage temperature range (°F / °C) Noise emissions Humidity (%) Enclosure rating (Inverter / PSD) Cooling Altitude (ft./m) (-22 to 158 / -30 to 70) < 58 db 0 to 95 non condensing NEMA 3R Forced convection with variable speed fan 8000 / 2400 Communications and user interface Graphical user interface with 3 LED status indicators Connectivity Ethernet, Modbus (TCP IP), USB, RS485, S0 output Agency approvals / Regulatory compliance UL / IEEE / CSA / FCC Fault signal relay DC polarity safeguard GFDI compliant with NEC 690.35 for use with ungrounded PV system arrays 1 UL 1741 2nd Ed. 2010 / CSA C22.2 No. 107.1 / IEEE 1547 / FCC Class A Potential free normally open contact Short circuit diode IEC 62109-2 certified by Bureau Veritas for residual ground fault current isolation monitor and interrupter function. Possible power output derate between 45-60° C T: +1 ( 86 6 ) 5 2 2 6 7 6 5 • F: + 1 ( 5 3 0 ) 4 7 7 5 9 9 5 k a c oinf o@k a c o- n e w e n e r g y. co m • w w w . k a co - n e w e n e r g y. co m Specifications are subject to change without notice. KACO blueplanet TL3 04/25/14 User interface